SLOWER DOOR TEST FORM
Mouse Infiltration hest Certification L"'o, f �
Prescriptive and Perform nce Method
Contractor:
Job Address: g f ( Q rhu L L FL 3%F1 Sl
Construction: New Construction — Car npiete Existing — After Addition
House Infiltration :'est Results SLC Climate Zone 2
CFM (50) = l i E5't Date:
volume = 2 6 U 6 Z . -],
ACH (50) = CFM (50)11 60 / Volume = _ 3 , g Mechanical Ventilation required less than 3 AA Chi
Passing results must be & ACH (50) or less V1 Pass ( ) Fail
FBC, EneiyV
T
he building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553-993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code o7fuial. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
F8C, Residen'dal
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
Pressure of 0.2 inch w. c. (50 Pa) in accordance with Section 11402 4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Commmy
Company Name: Pro -Duct Services Address: '1915 Rio Vista Drive, Ft. Pierce, FL 34949
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section 8402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Markin Klein
License/Certification #: 5061633