HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: DRAGOMIR RESIDENCE
Builder Name:
Street: 10527 QAKBRIDGE COURT
Permit Office: ST LUCIE COU TY
JAN 1 7 2020
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: MARCEL DRAGOMIR
Jurisdiction: ST LUCIE CQ�1 TY
Permitting
Design Location: FL, Fort Pierce
County: St. Lucie (Florid C5'irTial,,�0 -04rlty,
1. New construction or existing New (From Plans)
9. Wall Types (3244.3 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 2934.30 ft2
b. Frame - Wood, Adjacent
R=13.0 309.92 ft
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (3237.0. sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 3237.00 ft'
6. Conditioned floor area above grade (ft2) 3237
b. N/A
R= ft2
2
_ ft
R
Conditioned floor area below grade (ft2) 0
11 Ducts
R ft'
7. Windows(377.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 175
a. U-Factor: SgI, U=0.32 265.30 ft'
b. Sup: Attic, Ret: Attic, AH: Attic
6 125
SHGC: 5HGC=0.22
b. U-Factor: SgI, U=0.35 112.00 ft2
12. Cooling systems
kBt Efficiency
a. Central Unit
41.0 .0 SEER:16.00
SHGC: SHGC=0.20
b. Central Unit
18.8 SEER:16.00
c. U-Factor: NIA ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
b. Electric Strip Heat
17.0 COP:1.00
Area Weighted Average Overhang Depth: 2.000 ft
Area Weighted Average SHGC: 0.214
14. Hot water systems
a. Electric
Cap: 50 gallons
B. Floor Types (3237.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 3237.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.117 . Total Proposed Modified Loads: 96.23
P A @
Total Baseline Loads: 97.22
f1�7s
�7
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance,
with the Florida Energy Code.
is
PREPARED BY:
Before construction completed
DATE: 8-23-19 1
this building will be inspected for
compliance with Section 553.908
hereby certify that this buildin s designed, is in compliance
Florida Statutes.
with the Florida Energy Cod
OWNER/AGENT
BUILDING OFFICIAL:
DATE:
DATE:
L� -LL I I
- -
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). "
8/22/2019 11:25 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (20 F) rr4�i'&MPware Page 1 of 7
FORM R405-2017 INPU I SUMMAKY L;MtL;KL15 I KtF'UK I
PROJECT
Title:
DRAGOMIR RESIDENCE
Bedrooms: 2 •
Address Type:
Street Address
Building Type:
User
Conditioned Area: 3237
Lot #
Owner Name:
MARCEL DRAGOMIR
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
10527 OAKBRIDGE
CO
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH .MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
AHU 1
2188
21506.8
2
AHU 2
1049
10110.7
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
DINING
266
2473.8 No
0
1
Yes
Yes
Yes
2
FLEX ROOM
255
2575.5 No
0
1
Yes
Yes
Yes
3
FOYER
204
1897.2 No
0
1
Yes
Yes
Yes
4
GREAT ROOM
396
4237.2 No
0
1
Yes
Yes
Yes
5
BEDROOM 2
254
2362.2 No
0
1
1
Yes
Yes
Yes
6
PANTRY
62
576.6 No
0
1
No
Yes
Yes
7
HALL
107
995.1 No
0
1
Yes
Yes
Yes
8
BATH 2
77
716.1 No
0
1
Yes
Yes
Yes
9
CLST 2
47
437.1 No
0
1
Yes
Yes
Yes
10
LAUNDRY
72
669.6 No
0
1
Yes
Yes
Yes
11
ENTRY
48
446.4 No
0
1
No
Yes
Yes
12
KITCHEN
400
4120 Yes
0
1
Yes
Yes
Yes
13
M WIC 1
64
595.2 No
0
1
Yes
Yes
Yes
14
M WIC 2
56
520.8 No
0
1
No
Yes
Yes
15
M TOILET
40
372 No
0
1
Yes
Yes
Yes
16
M BATH
142
1320.6 No
0
1
Yes
Yes
Yes
17
OFFICE CLST 2
10
93 No
0
1
No
Yes
Yes
18
OFFICE
196
1822.8 No
0
1
Yes
Yes
Yes
19
OFFICE CLST
36
334.8 No
0
1
Yes
Yes
Yes
20
BATH 3
60
558 No
0
1
Yes
Yes
Yes
21
HALLWAY
90
837 No
0
1
No
Yes
Yes
8/22/2019 11:25 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FnRM Ran.S-9nl7 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number
Name Area Volume'
Kitchen Occupants
Bedrooms
Infil ID, Finished
Cooled '
Heated
22
MASTER BEDR00 355 3656.5
No
0
1
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
1 Slab -On Grade Edge Insulation
DINING
15 ft
0
266 ft2
1
0
0
2 Slab -On -Grade Edge Insulation
FLEX ROOM
32 ft
0
255 ft2
1
0
0
3 Slab-OrrGrade Edge Insulation
FOYER
18 ft
0
204 ft2
____
1
0
0
4 Slab -On, -Grade Edge Insulation
GREAT ROOM
22 ft
0
396 ft2
_--_
1
0
0
5 Slab -On -Grade Edge Insulation
BEDROOM 2
30 ft
0
254 ft2
____
1
Q
0
6 Slab -On -Grade Edge Insulation
PANTRY
1 ft
0
62 ft2
____
1
0
0
7 Slab -Or --Grade Edge Insulation
HALL
11.2 ft
0
107 ft2
____
1
0
0
8 Slab -On -Grade Edge Insulation
BATH 2
loft
0
77 ft2
____
1
0
0
9 Slab -On -Grade Edge Insulation
CLST 2
19 ft
0
47 ft2
----
1
0
0
10SIab-On-Grade Edge Insulation
LAUNDRY
8ft
0 -
72 ft2
----
1
0
0
11SIab-On-Grade Edge Insulation
ENTRY
1 ft
0
48 ft2
----
1
0
0
12SIab•On-Grade Edge Insulation
KITCHEN
24 ft
0
400 ft2
____
1
0
0
13SIab-On-Grade Edge Insulation
M W IC 1
8ft
0
64 ft2
1
0
0
14SIab-On,Grade Edge Insulation
M W IC 2
1 ft
0
56 ft2
1
0
0
15SIab-On-Grade Edge Insulation
M TOILET
5 ft
0
40 ft2
1
0
0
16SIab-On-Grade Edge Insulation
M BATH
22 ft
0
142 ft2
0
0
17Slab-On-Grade Edge Insulation
OFFICE CLST 2
1 ft
0
10 ft2
1
0
0
18SIab-On-Grade Edge Insulation
OFFICE
19 ft
0
196 ft2
e__
1
0
0
19SIab•On-Grade Edge Insulation
OFFICE CLST
15 ft
0
36 ft2
1
0
0
20SIab-Orr-Grade Edge Insulation
BATH 3
8ft
0
60 ft2
----
1
0
0
21SIab•On-Grade Edge Insulation
HALLWAY
1 ft
0
90 ft2
1
0
0
22SIab-On-Grade Edge Insulation
MASTER BEDRO
36 ft
0
355 ft2
1
0
0
ROOF
/
Roof
Gable
Roof
Rad
Solar SA Emitt
Emitt Deck
Pitch
# Type Materials Area
Area
Color
Barr
Absor. Tested
Tested Insul.
(deg)
1 Hip
Metal 3506 ft2
0 ft2
Light
N
0.6 No 0.9
No 20
22.6
-
ATTIC
Area
RBS IRCC
V
# Type
Ventilation
Vent Ratio (1
in)
1 Full attic
Unvented
0
3237 ft2
N N
FORM R405-2017 INVU I SUMMAKY L;Ntt;KL1b I KtrUK I
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented) DINING
0
Blown
266 ft2
0.1
Wood
2
Under Attic (Unvented) FLEX ROOM
0
Blown
255 ft2
0.1
Wood
3
Under Attic (Unvented) FOYER
0
Blown
204 ft2
0.1
Wood
4
Under Attic (Unvented) GREAT ROOM
0
Blown
396ftz
0.1
Wood
5
Under Attic (Unvented) BEDROOM 2
0
Blown
254 ft2
0.1
Wood
6
Under Attic (Unvented) PANTRY
0
Blown
62 ft2
0.1
Wood
7
Under Attic (Unvented) HALL
0
Blown
107 ft2
0.1
Wood
8
Under Attic (Unvented) BATH 2
0
Blown
77 ftz
0.1
Wood
9
Under Attic (Unvented) CLST 2
0
Blown
47 ft2
0.1
Wood
10
Under Attic (Unvented) LAUNDRY
0
Blown
72 ft2
0.1
Wood
11
Under Attic (Unvented) ENTRY
0
Blown
48 ft2
0.1
Wood
12
Under Attic (Unvented) KITCHEN
0
Blown
400 ft2
0.1
Wood
13
Under Attic (Unvented) M WIC 1
0
Blown
64 ft2
0.1
Wood
14
Under Attic (Unvented) M WIC 2
0
Blown
56 ft2
0.1
Wood
15
Under Attic (Unvented) M TOILET
0
Blown
40 T
0.1
Wood
16
Under Attic (Unvented) M BATH
0
Blown
142 ftz
0.1
Wood
17
Under Attic (Unvented) OFFICE CLST 2
0
Blown
10 ft2
0.1
Wood
18
Under Attic (Unvented) OFFICE
0
Blown
196 ftz
0.1
Wood
19
Under Attic (Unvented) OFFICE CLST
0
Blown
36 ft2
0.1
Wood
20
Under Attic (Unvented) BATH 3
0
Blown
60 ft2
0.1
Wood
21
Under Attic (Unvented) HALLWAY
0
Blown
90 ft2
0.1
Wood
22
Under Attic (Unvented) MASTER BEDRO 0
Blown
355 ft2
0.1
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
Space
1
S
Exterior Concrete Block- Ext Insul DINING
4.1
15
0 9
'4
140.0 ft2
0
0
0.6
0
2
N
Exterior Concrete Block - Ext InsiALEX ROOM
4.1
17
0 10
1
171.4 ft2
0
0.1
0.6
0
3
E
Exterior Concrete Block- Ext InsiffLEX ROOM
4.1
15
0 10
1
151.3 ft2
0
0.1
0.6
0
_ 4
W
Garage Frame - Wood FLEX ROOM
13
15
0 10
1
151.3 ft2
0
0.1
0.6
0
5
N
Exterior Concrete Block - Ext Insul FOYER
4.1
18
0 9
4
168.0 ft2
0
0.1
0.6
0
6
S
Exterior Concrete Block - Ext InstSREAT ROO
4.1
22
0 10
8
234.7 ft2
0
0.1
0.6
0
7
E
Exterior Concrete Block - Ext InsSEDROOM 2
4.1
13-
0 9
4
121.3 ft2
0
0.1
0.6
0
8
S
Exterior Concrete Block - Ext Inst8EDROOM 2
4.1
17
0 9
4
158.7 ftz
0
0.1
0.6
0
_ 9
N
Garage Frame - Wood PANTRY
13
2
0 9
4
18.7 ft2
0
0.1
0.6
0
10
E
Exterior Concrete Block - Ext Insul HALL
4.1
7
0 9
4
65.3 ft2
0
0.1
0.6
0
11
SE
Exterior Concrete Block - Ext Insdl HALL
4.1
4
3 9
4
39.7 ft2
0
0.1
0.6
0
12
N
Exterior Concrete Block - Ext Insul BATH 2
4.1
3
0 9
4
28.0 ft2
0
0.1
0.6
0
13
W
Exterior Concrete Block - EA Insul BATH 2
4.1
7
0 9
4
65.3 ft2
0
0.1
0.6
0
14
S
Exterior Concrete Block - Ext Insul CLST 2
4.1
3
0 9
4
28.0 ft2
0
0.1
0.6
0
_ 15
W
Exterior Concrete Block - Ext Insul CLST 2
4.1
16
0 9
4
149.3 ft2
0
0.1
0.6
0
16
W
Exterior Concrete Block - Ext InsuILAUNDRY
4.1
8
0 9
4
74.7 ft2
0
0.1
0.6
0
17
N
Garage Frame - Wood LAUNDRY
13
9
0 9
4
84.0 ft2
0
0.1
0.6
0
18
N
Garage Frame - Wood ENTRY
13
6
0 9
4
56.0 ftz
0
0.1
0.6
0
8/22/2019 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R405-2017
INPUT 5UMMAK7 C HhGKLlti I Ktt'UK I
WALLS
Adjacent
Space
Cavity
Width
Height
Sheathing Framing
Solar
Below
_ 19
E
Exterior
Concrete Block - Ext Insul KITCHEN
4.1
4
0
10
4
41.3 f?
0
0.1
0.6
0
_ 20
W
Exterior
Concrete Block - Ext Insul KITCHEN
4.1
20
0
10
4
206.7 ft2
0
0.1
0.6
0
_ 21
E
Exterior
Concrete Block- Ext Insul M WIC 1
4.1
8
0
9
4
74.7 ft2
0
0.1
0.6
0
22
E
Exterior
Concrete Block - Ext Insul M TOILET
4.1
5
0
9
4
46.7 ft2
0
0.1
0.6
0
_
_ 23
N
Exterior
Concrete Block - Ext Insul M BATH
4.1
14
0
9
4
130.7 ft2
0
0.1
0.6
0
_ 24
E
Exterior
Concrete Block - Ext Insul M BATH
4.1
8
0
9
4
74.7 ft2
0
0.1
0.6
0
_ 25
N
Exterior
Concrete Block - Ext Insul OFFICE
4.1
13
0
9
4
121.3 ft2
0
0.1
0.6
0
_ 26
E
Exterior
Concrete Block - Ext Insul OFFICE
4.1
3
0
9
4
28.0 ft2
0
0.1
0.6
0
_ 27
W
Exterior
Concrete Block - Ext Insul OFFICE
4.1
3
0
9
4
28.0 ft2
0
0.1
0.6
0
_ 28
N
Exterior
Concrete Block - Ext InsLOFFICE CLS
4.1
3
0
9
4
28.0 ft2
0
0.1
0.6
0
_ 29
W
Exterior
Concrete Block - Ext InsdDFFICE CLS
4.1
12
0
9
4
112.0 ft2
0
0.1
0.6
0
_ 30
S
Exterior
Concrete Block - Ext Insul BATH 3
4.1
6
0
9
4
56.0 ft2
0
0.1
0.6
0
_ 31
W
Exterior
Concrete Block - Ext Insul BATH 3
4.1
2
0
9
4
18.7 ft2
0
0.1
0.6
0
_ 32
E
Exterior
Concrete Block - Ext InsLMASTER BE
4.1
17
0
10
4
175.7 ft2
0
0.1
0.6
0
33
S
Exterior
Concrete Block - Ext InsLMASTER BE
4.1
19
0
10
4
196.3 ft2
0
0
0.6
0
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N Insulated FOYER None .39 3 8 24 ft2
WINDOWS
Orientation shown is the entered, Proposes
/
Wall
V #
Ornt
ID
Frame
Panes
NFRC
U-Factor
SHGC
Iml
1
S
1
Vinyl
Low-E Single
Yes
0.32
0.22
N
2
N
2
Vinyl
Low-E Single
Yes
0.32
0.22
N
3
N
5
Vinyl
Low-E Single
Yes
0.32
0.22
N
4
N
5
Vinyl
Low-E Single
Yes
0.32
0.22
N
_ 5
S
6
Vinyl
Low-E Single
Yes
0.32
0.22
N
_ 6
S
6
Vinyl
Low-E Single
Yes
0.35
0.2
N
T 7
E
7
Vinyl
Low-E Single
Yes
0.32
0.22
N
_ 8
S
8
Vinyl
Low-E Single
Yes
0.32
0.22
N
9
E
10
Vinyl
Low-E Single
Yes
0.35
0.2
N
10
SE
11
Vinyl
Low-E Single
Yes
0.32
0.22
N
_ 11
W
13
Vinyl
Low-E Single
Yes
0.32 ,
0.22
N
12
W
16
Vinyl
Low-E Single
Yes
0.32
0.22
N
13
W
20
Vinyl
Low-E Single
Yes
0.32
0.22
N
14
E
21
Vinyl
Low-E Single
Yes
0.32
0.22
N
_ 15
N
23
Vinyl
Low-E Single
Yes
0.32
0.22
N
16
N
25
Vinyl
Low-E Single
Yes
0.32
0.22
N
17
S
30
Vinyl
Low-E Single
Yes
0.32
0.22
N
18
S
33
Vinyl
Low-E Single
Yes
0.32
0.22
N
Overhang
Area
Depth
Separatic
15.0ft2
2ft0in
1ft4in
30.0 ft2
2ft0in
1ft4in
15.0ft2
2ft0in
1ft4in
8.0ft2
2ft0in
1ft4in
15.0ft2
2ft0in
1ft4in
72.0ft2
2ft0in
1ft4in
30.0 ft2
2ft0in
1ft4in
30.0 ft'
2ft0in
1ft4in
40.0ft2
2ft0in
1ft4in
4.0 ft2
2 ft 0 in
1 ft 4 in
4.0 ft2
2 ft 0 in
1 ft 4 in
20.0ft2
2ft0in
1ft4in
16.0ft2
2ft0in
1ft4in
6.5ft2
2ft0in
1ft4in
7.8ft2
2ft0in
1ft4in
30.0 ft2
2 ft 0 in
1 ft 4 in
4.0 ft2
2ft0in
1ft4in
30.0 ft2
2 ft 0 in
1 ft 4 in
Int Shade Screening
None
None
None
None
None
None
None
Nate
None
None
None
None
None
None
None
Nave
None
Nate
None
None
None
None
None
None
None
None
None
None
Drapes/blinds
Exterior 5
None
None
None
None
None
None
8/22/2019 11:25 AM
EnergyGauge® USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software
Page 5 of 7
CnDnn Dnnr,-,:)n!7 IAIPI IT SI IMMARY C.14FC.KI IRT RFPnRT
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
725 ftz
725 ftz
32 ft 9 ft 13
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
ProposedACH(50)
.000434
3688.7 202.51 380.84 .1631 7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
2
Electric Strip Heat/
Electric Strip HeatI
None
None
COP:1 27 kBtu/hr 1
COP:1 17 kBtu/hr 2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit/
Central Unit/
Split
Split
SEER: 16 41 kBtulhr 1230 cfm 0.8 1
SEER: 16 18.8 kBtulhr 564 cfm 0.8 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.98 50 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ftZ
DUCTS
V #
-- Supply --
Location R-Value Area
--- Return --- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
2
Attic 6 175 f?
Attic 6 125 ft'
Attic
Attic
18 ftZ Default Leakage Garage (Default) c(Default) c
13 ftZ Default Leakage Attic (Default) c(Default) c
1 1
2 2
8/22/2019 11:25 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
r7nann annr-OM7 IMPI IT SIIMMARV f_I-IFrICI IST REPORT
TEMPERATURES
Programable Thermostat:
N
Ceiling Fans:
Jan
Feb
�X
A
Jun
Jun
Jul
il l
Aug
11'Aug
rl
Sep
Oct
Oct
Nov
Nov
Dec
Dec
Venting Jan
Feb
Mar
Apr
May
Jun
Ju
Sep
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Coding (WEH)
AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
7B
80
78
80
78
80
78
80
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
DINING
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FLEX ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
GREAT ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft..
ft2
ft
0.3
PANTRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
ENTRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8lbs/sq.ft.
ft2
ft
0.3
M WIC 1
Default(8 I bs/sq.ft.
ft2
ft
0.3
M WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sgJt.
ft2
ft
0.3
OFFICE CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
OFFICE
Default(8 Ibs/sq.ft.
ft2
ft
0.3
OFFICE CLST
Default(8lbs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 lbs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/s Jt.
ft2
ft
0.3
MASTER BEDROO
8/22/2019 11:25 AM EnergyGauge® USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location varies
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms 4. 2 13. Cooling system: Capacity 59.8
a) Split system SEER 16.0
5. Is this a worst case? (yes/no) 5. No b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.) 6. 3237 d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.329
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.214
c) Area 7c. 377.3
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
*Label required by Section R303.1.3
I certify that this home has com
saving features which will be in;
display card will be completed k
Builder Signatu
Address of New Home:
8/22/2019 11:26:19 AM
9a. 0.0
9b.
9c.
10A1,.
10A2. 4.1
10131. 13.0
10132.
11a. 0.0
11 b.
11 c.
11d. No
14. Heating system: Capacity 44.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.98
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
b) Cross ventilation No
c) Whole house fan No
d) Multizone cooling credit
e) Multizone heating credit
f) Programmable thermostat No
Florida Building Code, Energy Conservation, if not DEFAULT.
kith the Florida Building Code, Energy Conservation, through the above energy
(or exceeded) in this home before final inspection. Otherwise, a new EPL
on installed code compliant features.
Date: al (I � I qQ
7 OAKBRIDGE COURT City/FL Zip: FORT PIERCE. FL
EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: DRAGOMIR RESIDENCE Builder Name:
Street: 10527 OAKBRIDGE COURT Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
U
Owner: MARCEL DRAGOMIR Jurisdiction: ST LUCIE COUNTY
w
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERI
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
Ceilinglattic
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
Walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on installation
Narrow cavities
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilincis.
a. In addition, inspection of log walls shall be in accordance with the provisions of ILL-400.
812212019 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1