Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: DRAGOMIR RESIDENCE Builder Name: Street: 10527 QAKBRIDGE COURT Permit Office: ST LUCIE COU TY JAN 1 7 2020 City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: MARCEL DRAGOMIR Jurisdiction: ST LUCIE CQ�1 TY Permitting Design Location: FL, Fort Pierce County: St. Lucie (Florid C5'irTial,,�0 -04rlty, 1. New construction or existing New (From Plans) 9. Wall Types (3244.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 2934.30 ft2 b. Frame - Wood, Adjacent R=13.0 309.92 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (3237.0. sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 3237.00 ft' 6. Conditioned floor area above grade (ft2) 3237 b. N/A R= ft2 2 _ ft R Conditioned floor area below grade (ft2) 0 11 Ducts R ft' 7. Windows(377.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 175 a. U-Factor: SgI, U=0.32 265.30 ft' b. Sup: Attic, Ret: Attic, AH: Attic 6 125 SHGC: 5HGC=0.22 b. U-Factor: SgI, U=0.35 112.00 ft2 12. Cooling systems kBt Efficiency a. Central Unit 41.0 .0 SEER:16.00 SHGC: SHGC=0.20 b. Central Unit 18.8 SEER:16.00 c. U-Factor: NIA ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 2.000 ft Area Weighted Average SHGC: 0.214 14. Hot water systems a. Electric Cap: 50 gallons B. Floor Types (3237.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 3237.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.117 . Total Proposed Modified Loads: 96.23 P A @ Total Baseline Loads: 97.22 f1�7s �7 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance, with the Florida Energy Code. is PREPARED BY: Before construction completed DATE: 8-23-19 1 this building will be inspected for compliance with Section 553.908 hereby certify that this buildin s designed, is in compliance Florida Statutes. with the Florida Energy Cod OWNER/AGENT BUILDING OFFICIAL: DATE: DATE: L� -LL I I - - - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). " 8/22/2019 11:25 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (20 F) rr4�i'&MPware Page 1 of 7 FORM R405-2017 INPU I SUMMAKY L;MtL;KL15 I KtF'UK I PROJECT Title: DRAGOMIR RESIDENCE Bedrooms: 2 • Address Type: Street Address Building Type: User Conditioned Area: 3237 Lot # Owner Name: MARCEL DRAGOMIR Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 10527 OAKBRIDGE CO Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH .MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 2188 21506.8 2 AHU 2 1049 10110.7 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 DINING 266 2473.8 No 0 1 Yes Yes Yes 2 FLEX ROOM 255 2575.5 No 0 1 Yes Yes Yes 3 FOYER 204 1897.2 No 0 1 Yes Yes Yes 4 GREAT ROOM 396 4237.2 No 0 1 Yes Yes Yes 5 BEDROOM 2 254 2362.2 No 0 1 1 Yes Yes Yes 6 PANTRY 62 576.6 No 0 1 No Yes Yes 7 HALL 107 995.1 No 0 1 Yes Yes Yes 8 BATH 2 77 716.1 No 0 1 Yes Yes Yes 9 CLST 2 47 437.1 No 0 1 Yes Yes Yes 10 LAUNDRY 72 669.6 No 0 1 Yes Yes Yes 11 ENTRY 48 446.4 No 0 1 No Yes Yes 12 KITCHEN 400 4120 Yes 0 1 Yes Yes Yes 13 M WIC 1 64 595.2 No 0 1 Yes Yes Yes 14 M WIC 2 56 520.8 No 0 1 No Yes Yes 15 M TOILET 40 372 No 0 1 Yes Yes Yes 16 M BATH 142 1320.6 No 0 1 Yes Yes Yes 17 OFFICE CLST 2 10 93 No 0 1 No Yes Yes 18 OFFICE 196 1822.8 No 0 1 Yes Yes Yes 19 OFFICE CLST 36 334.8 No 0 1 Yes Yes Yes 20 BATH 3 60 558 No 0 1 Yes Yes Yes 21 HALLWAY 90 837 No 0 1 No Yes Yes 8/22/2019 11:25 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FnRM Ran.S-9nl7 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume' Kitchen Occupants Bedrooms Infil ID, Finished Cooled ' Heated 22 MASTER BEDR00 355 3656.5 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On Grade Edge Insulation DINING 15 ft 0 266 ft2 1 0 0 2 Slab -On -Grade Edge Insulation FLEX ROOM 32 ft 0 255 ft2 1 0 0 3 Slab-OrrGrade Edge Insulation FOYER 18 ft 0 204 ft2 ____ 1 0 0 4 Slab -On, -Grade Edge Insulation GREAT ROOM 22 ft 0 396 ft2 _--_ 1 0 0 5 Slab -On -Grade Edge Insulation BEDROOM 2 30 ft 0 254 ft2 ____ 1 Q 0 6 Slab -On -Grade Edge Insulation PANTRY 1 ft 0 62 ft2 ____ 1 0 0 7 Slab -Or --Grade Edge Insulation HALL 11.2 ft 0 107 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulation BATH 2 loft 0 77 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulation CLST 2 19 ft 0 47 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulation LAUNDRY 8ft 0 - 72 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulation ENTRY 1 ft 0 48 ft2 ---- 1 0 0 12SIab•On-Grade Edge Insulation KITCHEN 24 ft 0 400 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation M W IC 1 8ft 0 64 ft2 1 0 0 14SIab-On,Grade Edge Insulation M W IC 2 1 ft 0 56 ft2 1 0 0 15SIab-On-Grade Edge Insulation M TOILET 5 ft 0 40 ft2 1 0 0 16SIab-On-Grade Edge Insulation M BATH 22 ft 0 142 ft2 0 0 17Slab-On-Grade Edge Insulation OFFICE CLST 2 1 ft 0 10 ft2 1 0 0 18SIab-On-Grade Edge Insulation OFFICE 19 ft 0 196 ft2 e__ 1 0 0 19SIab•On-Grade Edge Insulation OFFICE CLST 15 ft 0 36 ft2 1 0 0 20SIab-Orr-Grade Edge Insulation BATH 3 8ft 0 60 ft2 ---- 1 0 0 21SIab•On-Grade Edge Insulation HALLWAY 1 ft 0 90 ft2 1 0 0 22SIab-On-Grade Edge Insulation MASTER BEDRO 36 ft 0 355 ft2 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 3506 ft2 0 ft2 Light N 0.6 No 0.9 No 20 22.6 - ATTIC Area RBS IRCC V # Type Ventilation Vent Ratio (1 in) 1 Full attic Unvented 0 3237 ft2 N N FORM R405-2017 INVU I SUMMAKY L;Ntt;KL1b I KtrUK I CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) DINING 0 Blown 266 ft2 0.1 Wood 2 Under Attic (Unvented) FLEX ROOM 0 Blown 255 ft2 0.1 Wood 3 Under Attic (Unvented) FOYER 0 Blown 204 ft2 0.1 Wood 4 Under Attic (Unvented) GREAT ROOM 0 Blown 396ftz 0.1 Wood 5 Under Attic (Unvented) BEDROOM 2 0 Blown 254 ft2 0.1 Wood 6 Under Attic (Unvented) PANTRY 0 Blown 62 ft2 0.1 Wood 7 Under Attic (Unvented) HALL 0 Blown 107 ft2 0.1 Wood 8 Under Attic (Unvented) BATH 2 0 Blown 77 ftz 0.1 Wood 9 Under Attic (Unvented) CLST 2 0 Blown 47 ft2 0.1 Wood 10 Under Attic (Unvented) LAUNDRY 0 Blown 72 ft2 0.1 Wood 11 Under Attic (Unvented) ENTRY 0 Blown 48 ft2 0.1 Wood 12 Under Attic (Unvented) KITCHEN 0 Blown 400 ft2 0.1 Wood 13 Under Attic (Unvented) M WIC 1 0 Blown 64 ft2 0.1 Wood 14 Under Attic (Unvented) M WIC 2 0 Blown 56 ft2 0.1 Wood 15 Under Attic (Unvented) M TOILET 0 Blown 40 T 0.1 Wood 16 Under Attic (Unvented) M BATH 0 Blown 142 ftz 0.1 Wood 17 Under Attic (Unvented) OFFICE CLST 2 0 Blown 10 ft2 0.1 Wood 18 Under Attic (Unvented) OFFICE 0 Blown 196 ftz 0.1 Wood 19 Under Attic (Unvented) OFFICE CLST 0 Blown 36 ft2 0.1 Wood 20 Under Attic (Unvented) BATH 3 0 Blown 60 ft2 0.1 Wood 21 Under Attic (Unvented) HALLWAY 0 Blown 90 ft2 0.1 Wood 22 Under Attic (Unvented) MASTER BEDRO 0 Blown 355 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 S Exterior Concrete Block- Ext Insul DINING 4.1 15 0 9 '4 140.0 ft2 0 0 0.6 0 2 N Exterior Concrete Block - Ext InsiALEX ROOM 4.1 17 0 10 1 171.4 ft2 0 0.1 0.6 0 3 E Exterior Concrete Block- Ext InsiffLEX ROOM 4.1 15 0 10 1 151.3 ft2 0 0.1 0.6 0 _ 4 W Garage Frame - Wood FLEX ROOM 13 15 0 10 1 151.3 ft2 0 0.1 0.6 0 5 N Exterior Concrete Block - Ext Insul FOYER 4.1 18 0 9 4 168.0 ft2 0 0.1 0.6 0 6 S Exterior Concrete Block - Ext InstSREAT ROO 4.1 22 0 10 8 234.7 ft2 0 0.1 0.6 0 7 E Exterior Concrete Block - Ext InsSEDROOM 2 4.1 13- 0 9 4 121.3 ft2 0 0.1 0.6 0 8 S Exterior Concrete Block - Ext Inst8EDROOM 2 4.1 17 0 9 4 158.7 ftz 0 0.1 0.6 0 _ 9 N Garage Frame - Wood PANTRY 13 2 0 9 4 18.7 ft2 0 0.1 0.6 0 10 E Exterior Concrete Block - Ext Insul HALL 4.1 7 0 9 4 65.3 ft2 0 0.1 0.6 0 11 SE Exterior Concrete Block - Ext Insdl HALL 4.1 4 3 9 4 39.7 ft2 0 0.1 0.6 0 12 N Exterior Concrete Block - Ext Insul BATH 2 4.1 3 0 9 4 28.0 ft2 0 0.1 0.6 0 13 W Exterior Concrete Block - EA Insul BATH 2 4.1 7 0 9 4 65.3 ft2 0 0.1 0.6 0 14 S Exterior Concrete Block - Ext Insul CLST 2 4.1 3 0 9 4 28.0 ft2 0 0.1 0.6 0 _ 15 W Exterior Concrete Block - Ext Insul CLST 2 4.1 16 0 9 4 149.3 ft2 0 0.1 0.6 0 16 W Exterior Concrete Block - Ext InsuILAUNDRY 4.1 8 0 9 4 74.7 ft2 0 0.1 0.6 0 17 N Garage Frame - Wood LAUNDRY 13 9 0 9 4 84.0 ft2 0 0.1 0.6 0 18 N Garage Frame - Wood ENTRY 13 6 0 9 4 56.0 ftz 0 0.1 0.6 0 8/22/2019 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT 5UMMAK7 C HhGKLlti I Ktt'UK I WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 19 E Exterior Concrete Block - Ext Insul KITCHEN 4.1 4 0 10 4 41.3 f? 0 0.1 0.6 0 _ 20 W Exterior Concrete Block - Ext Insul KITCHEN 4.1 20 0 10 4 206.7 ft2 0 0.1 0.6 0 _ 21 E Exterior Concrete Block- Ext Insul M WIC 1 4.1 8 0 9 4 74.7 ft2 0 0.1 0.6 0 22 E Exterior Concrete Block - Ext Insul M TOILET 4.1 5 0 9 4 46.7 ft2 0 0.1 0.6 0 _ _ 23 N Exterior Concrete Block - Ext Insul M BATH 4.1 14 0 9 4 130.7 ft2 0 0.1 0.6 0 _ 24 E Exterior Concrete Block - Ext Insul M BATH 4.1 8 0 9 4 74.7 ft2 0 0.1 0.6 0 _ 25 N Exterior Concrete Block - Ext Insul OFFICE 4.1 13 0 9 4 121.3 ft2 0 0.1 0.6 0 _ 26 E Exterior Concrete Block - Ext Insul OFFICE 4.1 3 0 9 4 28.0 ft2 0 0.1 0.6 0 _ 27 W Exterior Concrete Block - Ext Insul OFFICE 4.1 3 0 9 4 28.0 ft2 0 0.1 0.6 0 _ 28 N Exterior Concrete Block - Ext InsLOFFICE CLS 4.1 3 0 9 4 28.0 ft2 0 0.1 0.6 0 _ 29 W Exterior Concrete Block - Ext InsdDFFICE CLS 4.1 12 0 9 4 112.0 ft2 0 0.1 0.6 0 _ 30 S Exterior Concrete Block - Ext Insul BATH 3 4.1 6 0 9 4 56.0 ft2 0 0.1 0.6 0 _ 31 W Exterior Concrete Block - Ext Insul BATH 3 4.1 2 0 9 4 18.7 ft2 0 0.1 0.6 0 _ 32 E Exterior Concrete Block - Ext InsLMASTER BE 4.1 17 0 10 4 175.7 ft2 0 0.1 0.6 0 33 S Exterior Concrete Block - Ext InsLMASTER BE 4.1 19 0 10 4 196.3 ft2 0 0 0.6 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated FOYER None .39 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposes / Wall V # Ornt ID Frame Panes NFRC U-Factor SHGC Iml 1 S 1 Vinyl Low-E Single Yes 0.32 0.22 N 2 N 2 Vinyl Low-E Single Yes 0.32 0.22 N 3 N 5 Vinyl Low-E Single Yes 0.32 0.22 N 4 N 5 Vinyl Low-E Single Yes 0.32 0.22 N _ 5 S 6 Vinyl Low-E Single Yes 0.32 0.22 N _ 6 S 6 Vinyl Low-E Single Yes 0.35 0.2 N T 7 E 7 Vinyl Low-E Single Yes 0.32 0.22 N _ 8 S 8 Vinyl Low-E Single Yes 0.32 0.22 N 9 E 10 Vinyl Low-E Single Yes 0.35 0.2 N 10 SE 11 Vinyl Low-E Single Yes 0.32 0.22 N _ 11 W 13 Vinyl Low-E Single Yes 0.32 , 0.22 N 12 W 16 Vinyl Low-E Single Yes 0.32 0.22 N 13 W 20 Vinyl Low-E Single Yes 0.32 0.22 N 14 E 21 Vinyl Low-E Single Yes 0.32 0.22 N _ 15 N 23 Vinyl Low-E Single Yes 0.32 0.22 N 16 N 25 Vinyl Low-E Single Yes 0.32 0.22 N 17 S 30 Vinyl Low-E Single Yes 0.32 0.22 N 18 S 33 Vinyl Low-E Single Yes 0.32 0.22 N Overhang Area Depth Separatic 15.0ft2 2ft0in 1ft4in 30.0 ft2 2ft0in 1ft4in 15.0ft2 2ft0in 1ft4in 8.0ft2 2ft0in 1ft4in 15.0ft2 2ft0in 1ft4in 72.0ft2 2ft0in 1ft4in 30.0 ft2 2ft0in 1ft4in 30.0 ft' 2ft0in 1ft4in 40.0ft2 2ft0in 1ft4in 4.0 ft2 2 ft 0 in 1 ft 4 in 4.0 ft2 2 ft 0 in 1 ft 4 in 20.0ft2 2ft0in 1ft4in 16.0ft2 2ft0in 1ft4in 6.5ft2 2ft0in 1ft4in 7.8ft2 2ft0in 1ft4in 30.0 ft2 2 ft 0 in 1 ft 4 in 4.0 ft2 2ft0in 1ft4in 30.0 ft2 2 ft 0 in 1 ft 4 in Int Shade Screening None None None None None None None Nate None None None None None None None Nave None Nate None None None None None None None None None None Drapes/blinds Exterior 5 None None None None None None 8/22/2019 11:25 AM EnergyGauge® USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 CnDnn Dnnr,-,:)n!7 IAIPI IT SI IMMARY C.14FC.KI IRT RFPnRT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 725 ftz 725 ftz 32 ft 9 ft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000434 3688.7 202.51 380.84 .1631 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Strip Heat/ Electric Strip HeatI None None COP:1 27 kBtu/hr 1 COP:1 17 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split SEER: 16 41 kBtulhr 1230 cfm 0.8 1 SEER: 16 18.8 kBtulhr 564 cfm 0.8 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ftZ DUCTS V # -- Supply -- Location R-Value Area --- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 175 f? Attic 6 125 ft' Attic Attic 18 ftZ Default Leakage Garage (Default) c(Default) c 13 ftZ Default Leakage Attic (Default) c(Default) c 1 1 2 2 8/22/2019 11:25 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 r7nann annr-OM7 IMPI IT SIIMMARV f_I-IFrICI IST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: Jan Feb �X A Jun Jun Jul il l Aug 11'Aug rl Sep Oct Oct Nov Nov Dec Dec Venting Jan Feb Mar Apr May Jun Ju Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Coding (WEH) AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 7B 80 78 80 78 80 78 80 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 FLEX ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft.. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft2 ft 0.3 ENTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8lbs/sq.ft. ft2 ft 0.3 M WIC 1 Default(8 I bs/sq.ft. ft2 ft 0.3 M WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sgJt. ft2 ft 0.3 OFFICE CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 OFFICE Default(8 Ibs/sq.ft. ft2 ft 0.3 OFFICE CLST Default(8lbs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 lbs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/s Jt. ft2 ft 0.3 MASTER BEDROO 8/22/2019 11:25 AM EnergyGauge® USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location varies 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 59.8 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 3237 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.329 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.214 c) Area 7c. 377.3 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed *Label required by Section R303.1.3 I certify that this home has com saving features which will be in; display card will be completed k Builder Signatu Address of New Home: 8/22/2019 11:26:19 AM 9a. 0.0 9b. 9c. 10A1,. 10A2. 4.1 10131. 13.0 10132. 11a. 0.0 11 b. 11 c. 11d. No 14. Heating system: Capacity 44.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.98 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit f) Programmable thermostat No Florida Building Code, Energy Conservation, if not DEFAULT. kith the Florida Building Code, Energy Conservation, through the above energy (or exceeded) in this home before final inspection. Otherwise, a new EPL on installed code compliant features. Date: al (I � I qQ 7 OAKBRIDGE COURT City/FL Zip: FORT PIERCE. FL EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: DRAGOMIR RESIDENCE Builder Name: Street: 10527 OAKBRIDGE COURT Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: U Owner: MARCEL DRAGOMIR Jurisdiction: ST LUCIE COUNTY w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Ceilinglattic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls Walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation Narrow cavities readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilincis. a. In addition, inspection of log walls shall be in accordance with the provisions of ILL-400. 812212019 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1