Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
ect Summa Pro Job: wirightsof#� AHU 1 � Byte: Aug sz, zoos QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email: QUICKCALCSQAOLCOM' For. DRAGOMIR RESIDENCE 10527 OAKBRIDGE COURT, FORT PIERCE, FL JAN 17 ' `??0 Notes: Permitting ST. Lucie County, Design Information Weather. Fort Pierce, FL, US .Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 21025 Btuh Ducts 6999 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 28024 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heatingg Coolingg Area (ft') 2188 2188 Volume (ft') 21502 21502 Air changes/hour 0.26 0.14 Equiv. AVF (cfm) 93 50 Heating Equipment Summary Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range M Relative humidity. 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 20787 Btuh Ducts 9858 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 29113 Btuh Latent Cooling Equipment Load Sizing Structure 4076 Btuh Ducts 2748 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 6824 Btuh Equipment Total Load (Sen+Lat) 35937 Btuh Req. total capacity at 0.70 SHR 3.5 ton Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6042J1 AHRI ref Coil TEM4AOC42S41++TDR AHRI ref 8703699 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER, Heating Input 7.9 kW Sensible cooling 28700 Btuh Heating output 27060 Btuh Latent cooling 12300. Btuh Temperature rise 18 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.82 NMI U ' .1 Y c Calculations approved byACCA to meet all requirements c Manual J 8th Ed. -FlawrighltsofC^ 2019-Aug-22 11:10:07 ,.� µw ---+ Right -Suite® Universal 2019 19.0.08 RSU08101 Page 1 ...ocumnsts\Wrightsoft HVAC\DRAGOMIR RESIDENCE.rup Cale = MJ8 Front Door faces: N -+*-wrightsoft Right-M Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE. FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email: QUICKCALCS@AOLCOM Job: Date: Aug 22, 2019 By: 1 Room name FLEX ROOM FOYER 2 3 B posed wall Room height 32.0 ft 10.1 ft heat/cod 18.0 ft 9.3 ft heat/cool 4 Room dimensions 17.0 x 15.0 'ft 34.0 x 6.0 ft 5 Room area 255.0 ft2 204.0 ft2 Ty I Construction number U value (Btuh/ftz°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (13tuh) I Area (ft2) or perimeter (ft) Load (Btuh) Heat I Cod Gross I N/P/S Heat I Cod I Gross I N/P/S Heat Cad 6 ; 43 I rmsRoF me6ua 11 13A-4ocs „:. 0.143 a 4.00 2.19 152 152 607 331 0 0 wltEl"i 0 0 0 0 0 0 2 glazing, dr low-e 2 glazing, cir low-e 0.320 0.320 a a 0.00 8.96 0.00 24.75 0 0 0 0 0 0 0 0 0- 0 0 0 2 ftgging,r law �. z 00..32Q . e 8.96 25.09 d 0 Q . . ... Q .. Q 13A4ocs 0.Wl s 4.00 219. 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, cir low-e 0.320 0.320 s s 0.00 8.96 0.00. 9.41 0 0 0 0 0 0 0 0 0 0 0 2 grazin. cir low-e_ 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 0 ffs !M Y+ V fl C 16A 30md r 0.032 - 0.90 224 255. 255 229 x 57j 204 204 183 457 ..R F wio. ; . Sam. as mm M. ,... - Y."M. EM Mum _ E:,..n, .. F _ . MM . AMM . gm. mw wwwomon ' 1"a .,�k. x.5.�... x . . • k % x `k.".. � � : ,? x :i � 'z.r�f. AM, . nw.ax . . ��k�a �� . . S. � '>% .n . .:Kill[ .. . 6 c)AED excursion -77 -38 Envelope loss/gain 2888 1418 1817 1147 12 a) Infiltration 501 144 0 260 0 75 0 b) Room ventlation 0 13 Internal gains: Occupants @ 230 0 0 900 0 0 0 Applianceslother Subtotal Qines 6 to 13) 3389 2461 2077 12221 Less extemal load 0 0 0 0 0 0 0 0 Less transfer Redistribution 448 20 -2077 0 -1221 0 14 15 Subtotal Ductloads 33% 47% 3837 1277 2725 1292 33% 47% 0 0 Total mom load 5115 249 4017 179 1 0 0 0 0 Air required (cfm) Calculations approved byACCA to meet all requirements of Manual J 8th Ed._ -�}i- wrtlgtrt�oft" 2019-Aug-22 11:10:07 RightSuite® Universal 2019 19.0.08 RSU08101 Page 2 ' �' ...ocumnets%Wrightsoft WAC\DRAGOMIR RESIDENCE.rup Calc = M.18 Front Door faces: N +wriightsofr Right-JO Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email: QUICKCALCS@AOLCOM Job: Date: Aug 22, 2019 By: 1 Room name GREAT ROOM - BEDROOM 2 2 3 Exposed wall Room height 22.0 ft 10.7 ft heat/cool 30.0 ft 9.3 ft heaUcool 4 Room dimensions 22.0 x 18.0 ft 1.0 x 254.0 ft 5 Room area 396.0 ft' 254.0 fN Ty Construction U-value Or HTM Area (W) Load Area (M Load I number (Btuhlft'-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cod Gross I NIP/ S Heat Cod Gross I N/P/S Heat Cod, 13A40cs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 0.143 a 4.00 219 0 0.320 a 0.00. 0.00 0 0.320 a 8.96 24.75 0 0.320 8.96 25.05 - 0 RM _e s $ 0 F-a 0.143 s 4.00 Z19 235 0.320 s 0.00 0.00 0 0.320 s 8.96 9.41 15 01 C 134 141 121 91 364 199 0 0 0 0 30 2 269 743 0 0„ 9. 0; * ed C 158 128 513 280 0 0 0 0 30 30 269 282 6 c)AED excursion -132 -157 Envelope loss/gain 2565 1898 2783 2006 12 a) Infiltration 365 105 433 0 124 0 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 0 Appliances/other 1 2200 Subtotal Qlnes 6 to 13) 2930 4203 3215 2130 Less external load 0 0. 0 0 0 0 0 Less transfer Redistribution 0 896 527 1981 '1054 14 Subtotal 3826 4730 5197 3184 15 Duct loads 33% 47% 1274 2243 33% 47% 1730 1510 Total mom load 5100 249 6973 311 6927 338 4694 209 Air required (cfm) Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. wrlght-% i 2019-Aug-22 11:10:07 A " ^"^'^ Right -Suite® Universal 2019 19.0.08 RS1108101 Page 3 ...ocumnets\Wrightsoft HVAC\DRAGOMIR RESIDENCE.rup Cale = MJ8 Front Door faces: N -�+- vMghtsoft• Right-JO Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCI E LANE. FORT PIERCE. FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOLCOM Job: Date: Aug 22, 2019 By: 1 Room name PANTRY HALL 2 3 Exposed wall Room height 0 ft 9.3 ft heat/cod 11.2 ft 9.3 ft heat/coal 4 Room dimensions 1.0 x . 62.0 ft 1.0 x 106.5 ft 5 Room area 0 ft' 106.5 ft' Ty Construction number U-value (Btuh/ft2_°F) Or HTM Area (ft') or perimeter (ft) Load (Stuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cod Gross I N/P/S Heat I Cod I Gross I N/P/S Heat I Cod 11 V,1p 13A-4ocs 0:143 a 4.00 219 0 0 0 0 65. 25 100 0 54 0 --G 2 glazing, cir la -e 0.320 a 0.00 0.00 0 0 0 0 0 0 0 0 0 �L—_--GG 2 glazing, dr law-e 0.320 e 8.96 24.75 0 0 0 0 0 40 2. 360 7 1 V 13A-0ocs 0.143 s 4.00 219 0 0 0 0 0 0 0 0 0 0 0 2 glazing, dr Iow-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 2 dazing, dr laves 0.320 s 8.96 9.41 0 0 0 0 0 0 6 c)AED excursion -16 1 57 Envelope loss/gain 56 122 1158 1472 12 a) Infiltration 0 0 162 0 47 0 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 0 Applianceslother 4001 Subtotal (lines 6 to 13) 56 522 1320 1519 Less wdemal load 0 0 0 0 0 0 0 Less transfer 0 260 182 -1320 -1519 Redistribution 316 704 0 0 14 15 Subtotal Duct loads 330/6 47% 105 334 33% 47% 0 0 Total mom load 421 1 21 1038 46 0 0 0 0 Air required (cfm) Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wr9gl�i�oi't^ 2019-Aug-2211:10:07 Q= RightSuite® Universal 2019 19.0.08 RS110B101 Page 4 ..ocumnetslWdghtsoft HVAC\DRAGOMIR RESIDENCE.rup Calc = MJ8 Front Door faces: N -- wrightsoft Duct System Summary AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOLCOM Project• • For: DRAGOMIR RESIDENCE 10527 OAKBRIDGE COURT, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1367 cfm Job: Date: Aug 22, 2019 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1367 cfm 182 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) eig.Egv Ln (ft) Trunk BATH 2 h 2079 101 89 1.000 6.0 Ox 0 VIFx 34.9 115.0 SO BEDROOM 2 h 6927 338 209 1.000 8.0 Ox0 VIFx 39.2 115.0 st1 DI NINc c 3527 140 157 1.000 8.0 Ox 0 VIFx 41.8 135.0 st5 FLEX ROOM h . 5115 249 179 1.000 8.0 Ox0 VIFx 18.1 115.0 st2 GREAT ROOM c 3487 124 156 1.000 8.0 OX 0 VIFx 36.5 135.0 st5 GREAT ROOM -A c 3487 124 156 1.000 8.0 Ox 0 VIFx 46.5 135.0 st5 KITCHEN c 3400 106 152 1.000 8.0 Ox0 VIFx 15.7 115.0 st2 KITCHEN -A c 3400 106 152 1.000 8.0 Ox0 VIFx 27.0 115.0 SO LAUNDRY c 1593 58 71 1.000 6.0 Ox0 VIFx 9.9 115.0 st2 PANTRY c 1038 21 46 1.000 6.0 Ox0 VIFx 11.5 115.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 545 450 1.000 826 11.0 0 x 0 VinlFlx st5 Peak AVF 388 468 1.000 710 11.0 0 x 0 VinlFlx st2 st2 Peak AVF 822 917 1.000 857 14.0 0 x 0 VinlFlx -1 i- wrightsoft- +•-w-� Right -Suite@ Universal 2019 19.0.08 RSU08101 ..ocumnets%Wdghtsoft HVAC%DRAGOMIR RESIDENCE. rup Calc = MJ8 Front Door faces: 2019-Aug-22 11:10:09 Page 1 Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mad Trunk W Ox 0 1367 1367 0 0 0 0 Ox 0 MR .,` wrightsoft°° 2019-Aug-22 11:10:09 RightSuite® Universal 2019 19.0.08 RSU08101 Page 2 ...ocumnets\Wrightsoft WAC\DRAGOMIR RESIDENCE.rup Calc = MJB Front Door faces: N -- wrightsoft Duct System Summary AHU 2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Email: QUICKCALCS@AOL.COM iLroject intormation For. DRAGOMIR RESIDENCE 10527 OAKBRIDGE COURT, FORT PIERCE, FL External static pressure . Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0:500 in H2O 1.000 in/100ft 627 cfm Job: Date: Aug 22, 2019 By: Cooling 1.00 in H2O 0. in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 627 cfm 133 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 3 c 1029 43 48 1.000 6.0 Ox 0 VIFx 17.8 115.0 st3 M BATH h 2591 115 53 1.000 6.0 Ox 0 VIFx 10.7 115.0 st4 M TOILET h 586 26 20 1.000 5.0 Ox 0 VIFx 10.1 .115.0 st4 M WIC 1 c 978 43 45 1.000 6.0 Ox0 VIFx 12.6 115.0 st4 M WIC 2 C 433 4 20 1.000 5.0 Ox0 VIFx 9.2 115.0 st4 MASTER BEDROOM C 3226 105 149 1.000 8.0 Ox0 VIFx 14.3 115.0 st3 MASTER BEDROOM -A c 3226 105 149 1.000 8.0 Ox0 VIFx 10.6 115.0 st3 OFFICE h 4146 184 143 1.000 8.0 Ox0 VIFx 12.2 115.0 st4 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (Cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 373 282 1.000 844 9.0 0 x 0 VinlFlx st3 Peak AVF 254 345 1.000 633 10.0 0 x 0 V[nlFlx Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 627 627 0 0 0 0 Ox 0 VIFx wrigh#soft°° 2019-Aug-22 11:10:09 Right-Sulte® Universal 2019 19.0.08 RSU08101 Page 3 ACCIN ..ocumnets\Wrightsoft HVAC\DRAGOMIR RESIDENCE.rup Calc = MJ8 Front Door faces: N