HomeMy WebLinkAboutReview CommentsPlanning & Development Services Building & Cade Regulakan Division 2300 Lnrglnla Avenue Fort Pierce, FIL 34982 PROPERTY INFORMATION Address: 10527 Oakbridge Ct City / State / Zip: Fort Pierce, FI 34951 Parcel #: 1309-500-0009-000/9 Zoning: AG-1 REVIEW COMMENTS Owner(s): Marcel Dragomir Jurisdiction: SAINT LUCIE COUNTY Lot#: 6 Block: APPLICATION INFORMATION Permit Number: 2001-0332 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Business Name: Business Addr: City / State / Zip: REVIEWS AND COMMENTS Review Type Status Reviewed By ADDRESSING ASSIGNMENT COMPLETE Lori Bender Comment: DOCUMENTS MISSING 1/17/2020 Comment: 1/17/2020 Comment: ENVIRONMENTAL REVIEW Comment: FRONT COUNTER REVIEW Comment: NOTIFIED FOR PICK UP Page 1 Automatic Sprinkler System? No Fax Number: Date Started PENDING Deanna Givens 1/17/2020 NOTICE OF COMMERENCE VEG PERMIT FILED UNDER "D" FOR DRAGOMIR, NO FEE VEG PERMIT SENT TO ERD COMPLETE Lynn Swartzel 1/23/2020 COMPLETE Deanna Givens 1/1712020 PENDING Email: Date Completed Date Released 1/27/2020 1/27/2020 1/29/2020 1/29/2020 1117/2020 1/1712020 Comment: PLANS EXAMINER REVIE _ INCOMPL!TE- Jpi, Inc -Andrew 2/12/2020 2/6 Comment: FIRE SPRINKLERS REQUIRED PER SITE PLAN APPROVAL GM-07-005, MNSP-06-008. PROVIDE THE DESIGN FOR THE SPRINKLER SYSTEM. (P2904.1) • _M12 20 Comment: 2) SHEET S-2 & S-3- PROVIDE FOOTER DETAILS, SIZE & REINFORCING. ([A] 107.2.1) 2f2920_ Comment: 3) LINTELS NEED CLARIFICATION- PROVIDE A COMPLETE LINTEL SPECIFICATION. INCLUDE A LEGEND i FOR ALL ABBREVIATIONS. LENGTH OF LINTEL REQUIRED. ([A] 107.2.1) 21.fi= Comment: 4) PROVIDE VEHICLE PROTECTION FOR EQUIPMENT IN GARAGE. (M1307.3.1) / Planning & Development Str4ces Bulldittg & Cade Regul'ati on Division 2300 Virginia Avenue Fort Pierre, FL 34982 REVIEW COMMENTS Page 2 lcl- comment: 5) THERE IS A+/-10% DIFFERENCE IN THE CUBIC VOLUME BETWEEN THE PLANS AND ENERGY CALCULATIONS, PLEASE REVISE AS NEEDED. ([A] 107.2.1) "2 ' 2112I2020 Comment: 6 ) PLEASE PROVIDE A MECHANICAL PLAN WITH DUCT TYPE, LAYOUT, & DUCT SIZES LABELED. M1601.1 �""' 2%12/2020 Comment: 7 THE BTU'S ON THE ENERGY CALCULATIONS DO NOT MATCH THE MANUAL J. ([A] 107.2.1) ) 2%12121120' Comment: 8) PLEASE SPECIFY A ROOF UNDERLAYMENT. ([A] 107.2.1) �2T12/2020 -- Comment: 9) QUESTIONABLE SOILS HAVE BEEN FOUND IN THIS DEVELOPMENT, PLEASE PROVIDE A GEOTECHNICAL TEST REPORT WITH FOUNDATION RECOMMENDATIONS. (R401.4) ZONING REVIEW INCOMPLETE Angela Vassar 1/22/2020 Comment: THE PROPOSED SINGLE FAMILY RESIDENCE EXCEEDS THE ALLOWABLE 10% LOT COVERAGE FOR THIS 1/22/2020 PROPERTY. YOU HAVE TWO OPTIONS: *APPLY FOR A VARIANCE THROUGH THE PLANNING DEPARTMENT. *REDUCE THE SIZE OF THE HOUSE. 1/22/2020 Comment: THIS PERMIT WILL PROCEED TO PLAN REVIEW.