HomeMy WebLinkAboutWindows & Door Installation NotesFARLEY ENGINEERING, LLC
8800 North US 1 Ste 2, Sebastian, Florida 32958
(772) 589-6229 (772) 589-2296 fax
Frank Farley PE 40111 CA 28108
MARCIL DRAGOMIR
10527 OAK RIDGE CT.
ST. LUCIE COUNTY, FL
WINDOW/DOOR ATTACHMENT NOTES
NOTE #1 1/4" ULTRACON 1-3/4" MIN EMBED INTO CMU SPACED AT 6" FROM CORNER
AND 15" OC ALL SIDES
NOTE #2 (4) 1/4" ULTRACON X 1-3/4" MIN EMBED THROUGH MULL CLIP 1 " MIN FROM
EDGE
NOTE #3 1/4" ULTRACON 1-3/4" MIN EMBED INTO CMU SPACED AT 6 1/2" FROM
BOTTOM CORNER, 12" TOP CORNER, 17 7/8" OC MAX AT TIOP LITE,, 13 3/4" OC MAX BOTTOM
LITE, 10" MAX BETWEEN LITES
NOTE *4 1/4" ULTRACON 1-3/4" MIN EMBED INTO CMU (3) CLUSTERED AT PANEL
MEETING POINTS, (1) CENTERED BETWEEN MEETING POINTS, (5) EQUALLY SPED EACH
JAMB, (8) AT P HOOK
NOTE #5 1/4" ULTRACON 1-3/4" MIN EMBED INTO CMU SPACED AT 6 1/2" FROM
BOTTOM CORNER, 12" TOP CORNER, 17 7/8" OC MAX AT TIOP LITE, 13 3/4" OC MAX BOTTOM
LITE, 10" MAX BETWEEN LITES
NOTE #6 1/4" ULTRACON 1-3/4" MIN EMBED INTO CMU SPACED AT 6 1/2" FROM
BOTTOM CORNER, 12" TOP CORNER, 17 7/8" OC MAX AT TIOP LITE, 13 3/4" OC MAX BOTTOM
LITE, 10" MAX BETWEEN LITES
NOTE #7 (2) #10 PANHEAD WOOD SCREW PER CLIP, CLIPS SPACED AT 16" OC MAX
ALL ROOF ZONES. SCREWS SHALL PENETRATE WOOD DECK 3/16" MIN j%Jn 1 ulll,
ROOFING UNDERLAYMENT
�•� Q,P .• E N
S • <�. e,�
NOA 17-0614.22 POLYSTICK TU PLUS
yk ;' No 40111 '..
OPENING PRESSURE: N/A,
PRODUCT DESIGN PRESSURE: N/A
=
: t' z
ATACHMENT METHOD SELFSTICK
STATE
0'••
O F :W Z
<v
NOA 16-1216.02 GAF VERSA SHIELD
2020 07-2
,'`� '• �t o ? ••'
��FS; • O R I.
�i,�S�ONq�-���%%
OPENING PRESSURE: N/A, S�
-1111►1►►11110%$
PRODUCT DESIGN PRESSURE: N/A
ATACHMENT METHOD 12GA, 3/8"DIAM HEAD, ANNULAR RINGSHANK, 20 RINGS/INCH
SPACE @ 6" OC @ LAPS, 12" OC GRID IN FIELD
RECEIVED
AUG. 0 4 2020
COPY
3 "it i m ST. Lucie County, Permitting