Loading...
HomeMy WebLinkAbout5V CRIMPDEPARTMENT OF REGULATORY AND BOARD AND CODE ADMINISTRATION DI NOTICE OF ACCEPTANCE (ITOA Gulf Coast Supply & Manufacturing, 4020 SW 4491 Street Horseshoe Beach, FL. 32648 RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.goy/economy SCOPE: This NOA is being issued under the applic Lble rules and regulations governing the use of construction materials. The documentation submitted has been review and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other are s where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expi (In Miami Dade County) and/or the AHJ i or material tested for quality assurance pu manufacturer will incur the expense of su, of such product or material within their ju determined by Miami -Dade County Prodi of the applicable building code. This product is approved as described her including the High Velocity Hurricane Zc DESCRIPTION: 26 ga. Coastal 5V LABELING: Each unit shall bear a pert statement: "Miami -Dade County Product RENEWAL of this NOA shall be consi in the applicable building code negativel TERMINATION of this NOA will occ[ materials, use, and/or manufacture of the sales, advertising or any other purposes s this NOA shall be cause for termination [tion date stated below. The Miami -Dade County Product Control Section i areas other than Miami Dade County) reserve the right to have this product )oses. If this product or material fails to perform in the accepted manner, the i testing and the AHJ may immediately revoke, modify, or suspend the use sdiction. RER reserves the right to revoke this acceptance, if it is t Control Section that this product or material fails to meet the requirements , and has been designed to comply with the Florida Building Code of the Florida Building Code. Panel label with the manufacturer's name or logo, city, state and following 1 Approved", unless otherwise noted herein. after a renewal application has been filed and there has been no change -ting the performance of this product. after the expiration date or if there has been a revision or change in the .oduct or process. Misuse of this NOA as an endorsement of any product, for JI automatically terminate this NOA. Failure to comply with any section of d removal of NOA. ADVERTISEMENT: The NOA numbr preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in adve ising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire shall be available for inspection at the This NOA renews NOA# 14-0520.02 The submitted documentation was re, A shall be provided to the user by the manufacturer or its distributors and site at the request of the Building Official. consists of pages 1 through 5. �d by Alex Tigera. NOA No.: 19-0807.02 MAMI•DADE COUNTY Expiration Date: 08/21/24 Approval Date: 08/15/19 Page 1 of 5 ROOFING SYSTEM APPROVAL: Category: Roofing Sub-Cateeory Metal, Pan Material: Steel Deck Type: Wood Maximum Design Pressure -156.5 psf TRADE NAMES OF PRODUCTS Product Dimensior 26 ga. Coastal 5V- 1= varies Crimp Roof Panel w = 26" (24" covera h = 3/8" Min. Thickness (26ga.) Min. Yield Streng Trim Pieces 1= varies w = varie Min. Thickness (26ga.) MANUFACTURING LOCATION: 1. Horseshoe Beach, FL. 2. Sebring, FL. 3. Stuart, FL. EVIDENCE SUBMITTED: Test Agency PRI Construction Materials Technologies Force Engineering & Testing Inc Farabaugh Engineering and Testing, Inc. s (Non -Structural) ACTURED OR LABELED BY APPLICANT: Test Product Specifications Description TAS 110 Corrosion resistant, galvanized, preformed, Valspar coated, prefinished, metal panels. x.018" h: 67ksi 1.018" Test Identifier VLS-004-02-01 VLS-005-02-01 TAS 110 Standard flashing and trim pieces. Manufactured for each panel width. l 17 -0065T -07A -C T215 -08A Test Name/Report ASTM G 155 ASTM G 23 TAS 125 TAS 100 Date 02/22/13 02/22/13 08/02/13 08/13/14 NOA No.: 19-0807.02 MAMaDADECOU� Expiration Date: 08/21/24 " • Approval Date: 08/15/19 Page 2 of 5 APPROVED ASSEMBLIES: System A: Deck Type: Deck Description: Maximum Uplift Pressure: 26 ga. Coastal 5F -Crimp Roof Panel Wood, Non-insated New Constructi n 19/32" or greater plywood or wood plank, or for re -roofing 15/32" or greater plywood. See Table A be w. Deck Attachment: In accordance ith applicable Building Code, but in no case shall it be less than 8d ring Field Perimeter and Corner' shank nails spa ed 6" o.c. In reroofing, where the deck is less than 19/32°' thick (Minimum Maximum Fastener Spacing 15/32") the abov attachment method must be in addition to existing attachment. Underlayment: Minimum unde ayment shall be an ASTM D 226 Type II installed with a minimum 4" side - lap and 6" end- ps. Underlayment shall be fastened with corrosion resistant tin -caps and 12 gauge 1 1/4" an lar ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field the roll. Or, any approved underlayment having a current NOA. Fire Barrier: Any approved a barrier having a current NOA. Refer to a current fire directory listing for fire ratings of t s roofing system assembly as well as the location of the fire barrier within the assembly. a Limitation # 1. Valleys: Valley constru ion shall be in compliance with Roofing Application Standard RAS 133 and with Gulf Coas Supply & Manufacturing LLC's current published installation instructions. Metal Panels and Install the "26 . Coastal 5V -Crimp Roof Panel" and accessories in compliance with Gulf Accessories: Coast Supply & Manufacturing LLC's current, published installation instructions and details. Flashing, penet ations, valley construction and other details shall be constructed in compliance wit the minimum requirements provided in Roofing Application Standards RAS 133. Panel fasteners hall be #9-15 x 1-'/Z" self drilling, self tapping, hex head screws with sealing washer of suffi ient length to penetrate through the sheathing a minimum of 3/16 inch. Fasteners shall a installed at a maximum spacing as listed in Table A below parallel to the slope. Fasten shall be installed at a maximum of 12" o.c. at panel edge. See detail herein. NOA No.: 19-0807.02 M1AM143ADE COUNTY Expiration Date: 08/21/24 Approval Date: 08/15/19 Page 3 of 5 TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner' Maximum Design Pressures -108.5 psf -156.5 Dsf Maximum Fastener Spacing 12" o.c. 6" o.c. 1. Extrapolation shall not be allowed NOA No.: 19-0807.02 M1AM143ADE COUNTY Expiration Date: 08/21/24 Approval Date: 08/15/19 Page 3 of 5 LIMITATIONS 1. Fire classification is not part of this ratings of this product. 2. The maximum designed pressure lis and corners). Neither rational analy: pressure zones (i.e. perimeters, exte 3. Panel shall be roll formed in conth Roofing Application Standard RAS 4. All panels shall be permanently lal "Miami -Dade County Product Con below. All clips shall be permanen 5. All products listed herein shall have Rule 61 G20-3 of the Florida Admin APPROVED refer to a current Approved Roofing Materials Directory for fire herein shall be applicable to all roof pressure zones (i.e. field, perimeters, nor extrapolation shall be permitted for enhanced fastening at enhanced d corners and corners). us lengths from eave to ridge. Maximum lengths shall be described in the A with the manufacturer's name and/or logo, and the following statement: Approved" or with the Miami -Dade County Product Control Seal as seen labeled with the manufacturer's name and/or logo, and/or model. quality assurance audit in accordance with the Florida Building Code and rative Code. NOA No.: 19-0807.02 Expiration Date: 08/21/24 Approval Date: 08/15/19 Page 4 of 5 26 #9-15 x 1 1/2" 5V -Crimp Panel Plywood Decking (By others) PROFILE DRAWINGS DETAIL A COASTAL 5V -CRIMP ROOF PANEL 24" Coverage Screw , #9-15 x 1 1/2" Woodgrip Screw Moisture Barrier (By others) SeeTabA Herein f r Maximum Fasteni Spacing OF THIS ACCEPTANCE 5V Panel NOA No.: 19-0807.02 QMIAMMI-DMADE COUNTY Expiration Date: 08/21/24 C= Approval Date: 08/15/19 Page 5 of 5