Loading...
HomeMy WebLinkAboutSeptic InformationSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION PERMIT FOR: APPLICANT: Juan Quinteros OSTDS New PROPERTY ADDRESS: 4637 S Header Canal Rd port Pierce. FL 34945 LOT: 7 BLOCK: PROPERTY ID #: 3202-5000-0007-000-3 SUBDIVTSION: PERMIT 4:56-SF-2153829 APPLICATION #:AP1566127 DATE PAID: FEE PAID: RECEIPT #: DOCUMENT #: PR1410215 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 3B1.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T [ 1,050 ] GALLONS / CPT) Septic new CAPACITY A [ ] GALLONS / GPD NIA CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ ] D [ 667 ] SQUARE FEET Drainfield new SYSTEM R [ ] SQUARE FEET NIA SYSTEM A TYPE SYSTEM: [ ] STANDARD [ ] FILLED [XI MOUND [ ] I CONFIGURATION: [ ] TRENCH [XI BED [ ] N F LOCATION OF BENCHMARK: Site BM, NiD CL Of Rd, middle of DW I ELEVATION OF PROPOSED SYSTEM SITE [ 53.001[ INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT E BOTTOM OF DRAINFIELD TO BE [ 44.00][ INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT L D E 0 T H E R ILL REQUIRED: [2l.UU] INCHES EXCAVATION REQUIRED: [ 42.UU] INCHES The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 400 gpd. SPECIFICATIONS BY: TITLE: Brian J.Ingram Environmental Specialist II APPROVED BY: !;v'L yi1r ; {,a•. _ - TITLE: Environmental Specialist II BrianIJ Ingram DATE ISSUED: 09/2812,020 EXPIRATION DATE: DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC v 1.1.4 AP1566127 SE1368660 St. Lucie CHD 03/28/2022 Page 1 of 3 NOTICE OF RIGHTS A party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the Department, within twenty-one (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency Clerk's facsimile number is 850-413-8743. Mediation is not available as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative gearing, and this order shall become a 'final order'. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. St. Lucie County Health Department 5150 NW Milner Dr Port Saint Lucie, FL 34983 LH PAYING ON: #:56-SF-2153829 BILL DOC#:56-BID-4967255 CONSTRUCTIONAPPLICATION#:AP1566127 RECEIVED FROM: Jessica Quinteros _ AMOUNT PAID_ 6 60. 00 PAYMENT FORM: CREDIT CARD 08701G _ PAYMENT DATE: 09/03/2020 MAIL TO: Juan Quinteros FACILITY NAME: PROPERTY LOCATION: 4637 S Header Canal Rd Fort Pierce, FL 34945 7 Lot: Block: Property ID: 3202-500-0007-000-3 EXPLANATION or DESCRIPTION: QUANTITY FEE 128 - OSTDS Construction System Inspection Research Fee 1 $ 5.00 -1 - Surcharge (All) 1 $ 45.00 -1 - OSTDS New Permit Surcharge 1 $ 100.00 -1 - OSTDS Construction Application and Plan Review,New 1 $ 100.00 123 - OSTDS Construction Site Evaluation 1 $ 115.00 126 - OSTDS Construction Permit (New or Mod, Amendment) 1 $ 55.00 127 - OSTDS Construction System Inspection 1 $ 75.00 133 - OSTDS Construction Reinspection 1 $ 50.00 --1 - Well Construction 1 $ 115.00 RECEIVED BY: WhiohamJL AUDIT CONTROL NO. 56,-PID-4638015_..___ Note: 59-31037 �y»esr� STATE OF FLORIDA DEPARTMENT" OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL ,f- SYSTEM APPLICATION FOR CONSTRUCTION PERMIT PERMIT NO. DATE PAID: FEE PAID:p�(] RECEIPT #: APPLICATION FOR: [ti/] New System [ 7 Existing System [ ) Holding Tank [ ] innovative C ] Repair [ ] Abandonment C ] Temporary [ J APPLICANT: Juan R Quinteros W C i 1 AGENT. Jessica Quinteros TELEPHONE: 772-979-4956 MAILING ADDRESS: 4652 SW WADE DR PORT ST LUCIE FL 34953 TO BE COMPLETED BY APPLICANT OR AFPLICANT'SWAUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED BY A PERSON LICENSED PURSUANT TO 489.105(3) (m) OR 469.552, FLORIDA STATUTES. IT is TFCE APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PPOVISIONS. PROPERTY INFORMATION LOT: 7 BLOCK: SUBDIVISION! PERSNICKETY FARM PLATTED. 12/2009 PROPERTY ID # : 3202-500-0007-000-3 ZONING: AG-5 I/M OR EQUIVALENT: [ YIN j PROPERTY SIZE.: 10 ACRES WATER SUPPLY: [ I PRIVATE PUBLIC [ ]¢=2000GPD [ ].>2000GPD IS SEWER AVAILABLE AS PER 381.0065, FS? [ YIN ] DISTANCE TO SEWER: FT pROpERTY ADDRESS: 4637 S Header Canal Rd Fort Pierce FL DIRECTIONS TO PROPERTY: Head north on the Intersection of SR 70 & S Header Canal Rd Property is approximately ha(f a mile on the west side of S Header Canal Rd. � BUILDING INFORMATION [ ] RESIDENTIA13 [ I COMMERCIAL, Unit Type of No. of Building Commercial /Ins titiitional System Design No Establishment Bedrooms Area Sgft Table 1, Chapter 64E-6_, PAC _ Single Residential' 3 x: 2 3 4 C ] Floor/Equipment Drains [ ] Other (Specify) ii SIGNATURE: DH 4015, 08(�09 (Obsoletes previous editions which may not be used) Incorporated 64E-6.001, FAC DATE : Page 1 of 4 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATION APPLICANT: Juan Quinteros CONTRACTOR / AGENT LOT: 7 Jessica Quinteros BLOCK: SUBDIVISION. ID#:3202-5D00-0007-000-3 APPLICATION # AP1566127 PERMIT # 56-SF-2153829 DOCUMENT # SE1368660 TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [X]YES [ ]NO NET USABLE AREA AVAILABLE: 10.00 ACRES TOTAL ESTIMATED SEWAGE FLOW: 400 GALLONS PER DAY [ RESIDENCES —TABLET / OTHER —TABLE 2 ] AUTHORIZED SEWAGE FLOW: 15000.00 GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 2000.00 SQFT UNOBSTRUCTED AREA REQUIRED: 1000.00 SQFT BENCHMARK/REFERENCE POINT LOCATION: Site BM, NiD CL of Rd, middle of DW ELEVATION OF PROPOSED SYSTEM SITE 53_00 [ INCHES / FT ] [ ABOVE / HE] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: FT DITCHES/SWALES: FT NORMALLY WET: [ ]YES [X]NO WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: 100 FT NON -POTABLE: 100 FT BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 90 FT POTABLE WATER LINES: 95 FT SITE SUBJECT TO FREQUENT FLOODING? 10 YEAR FLOOD ELEVATION FOR SITE' WWT. AR nTPTT7 TNFr7RMATT(-]N CTTV.. 1 [ ]YES [X]NO 10 YEAR FLOODING? [ ]YES [X]NO] FT [ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD USDA SOIL SERIES: Munsell #/Color Texture Depth 10YR 612 Sand 0 To 19 10YR 5/8 CMNIPRM RF 15 To 21 1 OYR 712 Sand 16 To 21 10YR 512 Sandy Clay Loam 21 To 40 10YR 5/2 Loamy Sand 40 To 52 1 OYR 511 Sandy Clay Loam 52 To 72 SOIL PROFILE INFORMATION SITE 2 Munsell #/Color Texture Depth 1 OYR 511 Sand 0 To 6 1OYR 612 Sand 6 To 17 1OYR 7/1 Sand 17 To 23 1 OYR 5/2 Sandy Clay Loam 23 To 42 10YR 512 Loamy Sand 42 To 52 10YR 411 Sandy Clay Loam 52 To 72 OBSERVED WATER TABLE: 50.00 INCHES [.ABOVE / BELOW i EXISTING GRADE TYPE: [ PERCHED / APPARENT ] ESTIMATED NET SEASON WATER TABLE ELEVATION: 15 INCHES [ ABOVE / BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ]YES [X]NO MOTTLING: [XIYES [ ]NO DEPTH: 15.00 INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: DRAINFIELD CONFIGURATION: [ ] TRENCH [X] BED REMARKS/ADDITIONAL CRITERIA Sand10.60 DEPTH OF EXCAVATION: 42 INCHES [ ] OTHER (SPECIFY) ISWT determined using USDA WSS and soil borings. OYR618 CMN PROM RF mottling in 10YR/612 and 10YR712 matrix ?2% starting at 15" in SB1. 131 53" below BM. S132 54" below BM. SITE EVALUATED BY: C"� DATE: ingra Nan (Title: Environmental Specialist I]) (ENVIRONMENTAL HEALTH) DE d015, 06/09 (Obsoletes previous edi ons which may not be used) Incorporated: 64E-6.001, FAC AP1566127 E102153829 09/18/2020 Page 3 of 4 V 1.0.2 Michelle Franklin, C1=A -- Saint Lucie County Property Appraiser -- All rights reserved. Property identification Site Address: 4637 S Parcel ID: 3202-500-0007- Account#: 176161 Sce/Town/Range: 02/36S/38E HEADER CANAL RD 000-3 Map 117: 32/01 X Zoning: AG-5 Count Use Type: 6000 Jurisdiction, Saint Lucie County Ownership Legal Description Juan R Quinteros PERSNICKETY FARMS-(PB 66-40) LOT 7 Jessica Quiriteros 4652 SW Wade DR Port Saint Lucie, FL 34953 Current Values Historical Values 3-year Just(Market: $154,500 Assessed: S8,000 Year JustlMarket Assessed Exemptions Taxable Exemptions: $0 Taxable: S8,000 2020 $154,500 $8,000 $0 $8,000 2019 $131,325 $8.000 $0 $81000 2018 $122,740 $8,000 SO $8,000 Sale History Date Book/Page Sale Code Deed Grantor Price 01-20-2020 4372 / 2993 0001 Wit Butterfly Enterprises LLC $225,000 04-12-2004 1985 / 1946 XX60 SP Quex LLC $600,000 Primary Building information Finished Area. of this building. 0 SF Gross Sketched Area: 0 SF Exterior Data View: hoof Cover: Roof Structure: Building fie: Year Built: N/A frame: Gradc: Ef active Year; NIA Primary Wall: Story Height: No. units: 0 Secondary Wall: Interior Data Bedrooms: 0 A/C %: 0% Electric: Primary. Cnt Wall: Full Baths: 0 Heated %: N/A% Heat Typo: Avg Hgt/Floor: 0 Half Baths: 0 Sprinkled %: 0% Beat Fuel: Primary Floors: Type Total Areas Finished/UnderAir 0 (SF). - Gross Sketched Area 0 (SF): Land Size (acres): 10 Land Size (SP); 435,600 Total Building Count: 1 Special Features and Yard Items Qty Uizits Year Blt All information is believed to be correct at this time, but is subject to change and is provided without any warranty. 0 Copyright 2020 Saint Lucie County Property Appraiser. All rights reserved. E co o 0 �TL0 co N © O uO O I U� N -Ih C7 O — O i Ya F g{C S A M � d t s�yee.��1gg1�R�.,,xt�� ! t C4 3 ill ly es, k :+ O� Mg Custom Soil Resource Report St. Lucie County, Florida 32—Pineda sand, 0 to 2 percent slopes Map Unit Setting National map unit symbol: 2xl nb Elevation: 0 to 100 feet Mean annual precipitation: 47 to 58 inches Mean annual air temperature: 70 to 77 degrees F Frost -free period: 355 to 365 days Farmland classification: Farmland of unique importance Map Unit Composition Pineda and similar soils: 85 percent Minor components: 15 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Pineda Setting Landform: Drainageways on marine terraces, flats on marine terraces Landform position (three-dimensional): Tread, dip, talf Down -slope shape: Linear Across -slope shape. Concave, linear Parent material: Sandy and loamy marine deposits Typical profile A - 0 to 5 inches: sand E - 5 to 19 inches: sand Bw - 19 to 35 inches: sand Btg/E - 35 to 38 inches. sandy loam Btg - 38 to 60 inches: sandy loam Cg - 60 to 80 inches: loamy sand Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class. Poorly drained Runoff class: Very high Capacity of the most limiting layer to transmit water (Ksat): Moderately low to moderately high (0.06 to 0.20 inlhr) Depth to water table: About 3 to 18 inches Frequency of flooding: None Frequency of ponding: None Calcium carbonate, maximum content: 4 percent Maximum salinity: Nonsaline to very slightly saline (0.0 to 2.0 mmhoslcm) Sodium adsorption ratio, maximum: 4.0 Available water capacity: Low (about 4.6 inches) Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 3w Hydrologic Soil Group: Clb Forage suitability group: Sandy over loamy soils on flats of hydric or mesic lowlands (G155XB241FL) 10 Custom Soil Resource Report Other vegetative classification: Slough (R155XY011 FL), Sandy over loamy soils on flats of hydric or mesic lowlands (G155XB241 FL) Hydric soil rating. Yes Minor Components Malabar Percent of map unit: 6 percent Landform: — error in exists on --- Landform position (three-dimensional): Tread, dip, talf Down -slope shape: Linear, concave Across -slope shape: Linear, concave Ecological site: R155XY011 FL - Slough Other vegetative classification: Slough (R155XY011 FL), Sandy soils on flats of mesic or hydric lowlands (G155XB141FL) Hydric soil rating: Yes Wabasso Percent of map unit: 5 percent Landform: Flatwoods on marine terraces Landform position (three-dimensional): Tread, talf Down -slope shape. Linear Across -slope shape: Linear Other vegetative classification: South Florida Flatwoods (R155XY003FL), Sandy soils on flats of mesic or hydric lowlands (G155XB141 FL) Hydric soil rating: No Valkaria Percent of map unit: 2 percent Landform: Drainageways on flatwoods on marine terraces Landform position (three-dimensional). Tread, dip, talf Dawn -slope shape: Linear Across -slope shape: Linear, concave Other vegetative classification: Slough (RI 55XY011 FL), Sandy soils on flats of mesic or hydric lowlands (G155XB141FL) Hydric soil rating: Yes Hallandale Percent of map unit: 2 percent Landform: Flatwoods on marine terraces Landfomn position (three-dimensional): Tread, talf Down -slope shape: Linear Across -slope shape: Linear Other vegetative classification: South Florida Flatwoods (R155XY003FL), Sandy soils on flats of mesic or hydric lowlands (G155XB141FL) Hydric soil rating: Yes 38—Riviera fine sand, 0 to 2 percent slopes Map Unit Setting National map unit symbol: 2tzw2 11 Custom Soil Resource Report Elevation. 0 to 80 feet Mean annual precipitation. 44 to 59 inches Mean annual air temperature: 68 to 77 degrees F Frost -free period: 350 to 365 days Farmland classification: Farmland of unique importance Map Unit Composition Riviera and similar soils: 80 percent Minor components: 20 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Riviera Setting Landform: Drainageways on marine terraces, flats on marine terraces Landform position (three-dimensional): Tread, dip, talf Down -slope shape: Linear Across -slope shape: Linear, concave Parent material: Sandy and loamy marine deposits Typical profile A - 0 to 6 inches: fine sand E - 6 to 26 inches: fine sand Bt/E - 28 to 32 inches: fine sandy loam Stg - 32 to 42 inches: sandy clay loam C - 42 to 80 inches: fine sand Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class. Poorly drained Runoff class: Very high Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.60 to 6.00 inlhr) Depth to water table: About 3 to 18 inches Frequency of flooding: None Frequency of ponding: None Maximum salinity. Nonsaline to very slightly saline (0.0 to 2.0 mmhos/cm) Sodium adsorption ratio, maximum: 4.0 Available water capacity: Moderate (about 6.0 inches) Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 3w Hydrologic Soil Group: AID Forage suitability group: Sandy over loamy soils on flats of hydric or mesic lowlands (G155XB241FL) Othervegetative classification: Slough (R155XY011FL), Sandy over loamy soils on flats of hydric or mesic lowlands (GI56XB241 FL) Hydric soil rating: Yes Minor Components Wabassa Percent of map unit: 8 percent Landform: Flatwoods on marine terraces Landform position (three-dimensional): Tread, talf 12 Custom Soil Resource Report Down -slope shape: Linear, convex Across -slope shape: Linear Other vegetative classification: South Florida Flatwoods (R155XY003FL), Sandy soils on flats of mesic or hydric lowlands (G155XB141FL) Hydric soil rating: No Pinellas Percent of map unit, 4 percent Landform: Flatwoods on marine terraces Landform position (three-dimensional): Tread, talf Down -slope shape: Convex, linear Across -slope shape. Linear Other vegetative classification: Cabbage Palm Flatwoods (R155XY005FL), Sandy over loamy soils on flats of hydric or mesic lowlands (G1 55XB241 FL) Hydric soil rating: No Hallandale Percent of map unit: 4 percent Landform: Flatwoods on marine terraces Landform position (three-dimensional): Tread, talf Down -slope shape: Linear Across -slope shape: Linear Other vegetative classification: South Florida Flatwoods (R155XY003FL), Sandy soils on flats of mesic or hydric lowlands (G155XB141 FL) Hydric soil rating: Yes Floridana Percent of map unit: 2 percent Landform: Depressions on marine terraces Landform position (three-dimensional): Tread, dip Down -slope shape. Concave, linear Across -slope shape: Concave, linear Other vegetative classification: Freshwater Marshes and Ponds (R155XY010FL), Sandy over loamy soils on stream terraces, flood plains, or in depressions (0155XB245FL) Hydric soil rating. Yes Oldsmar Percent of map unit. 2 percent Landform: Flatwoods on marine terraces Landform position (three-dimensional): Talf Down -slope shape: Linear, convex Across -slope shape: Linear Other vegetative classification: South Florida Flatwoods (R155XY003FL), Sandy soils on flats of mesic or hydric lowlands (G155XB141FL) Hyddc soil rating: No 99—Water Map Unit Composition Water: 100 percent 13 Custom Soil Resource Report Estimates are based on observations, descriptions, and trarnsects of the mapunit. Description of Water Interpretive groups Land capability classification (irrigated)_ None specified Forage suitability group: Forage suitability group not assigned (G156BC999FL) Other vegetative classification: Forage suitability group not assigned (G156BC999FL) Hydric soil rating: Unranked 14