Loading...
HomeMy WebLinkAboutReview CommentsPROPERTY INFORMATION Address: 10655 S U S 1 City / State / Zip: Port St Lucie, FI 34952 Parcel#: 3414-501-5004-050/6 Zoning: CG APPLICATION INFORMATION Permit Number: 2003-0222 Permit Type: COMMERCIAL RENOVATION REVIEW COMMENTS e1 Owner(s): Paul A Zinter / Robin A Zinter Jurisdiction: SAINT LUCIE COUNTY Lot#: 4 Block: 4 Stories: Automatic Sprinkler System? No CONTRACTOR INFORMATION Contractor Name: Bryant H Melton Fax Number: 772-672-4581 AUG 2 C J00 Business Name: Coral Builders Llc Business Addr: 7269 Reserve Creek Dr J �1 p ; f ; ; , r_. ,�. a f' . ; 'e e n t ! Email: Bryant. Melton7269@Comc ast. Net City / State / Zip: Port Saint Lucie, Fl 34986 i! G f F' �` REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started FIRE DEPARTMENT REVIEW PENDING Tony-Jerger Comment: FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 3/9/2020 Comment: NOTIFIED FOR PICK UP PENDING Date Completed Date Released 3l9/2020 3/9/2020 Comment: PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 5/13/2020 5/13/2020 5/13/2020 Comment: PLANS EXAMINER MECHANICAL INCOMPLETE Steven Poreba 5/11/2020 Comment: PROVIDE ALTERATION LEVEL FMC 504 . 5/11/2020 THE NEW OCCUPANCY WILL BE REQUIRED TO SHOW COMPLIANCE WITH THE F.B.C. MECHANICAL FOR VENTILATION. FMC 504 PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 5/8/2020 Comment: YOU ARE REQUIRED PER SECTION 607.1 OF THE FLORIDA PLUMBING CODE TO PROVIDE TEMPERED WATER TO ALL SINKS. PLEASE SHOW LOCATION OF WATER HEATER 5/8/2020 Comment: YOU ARE REQUIRED BY SECTION 211.2 OF THE FLORIDA ACESSIBILITY CODE TO PROVIDE NO FEWER THAN TWO DRINKING FOUNTAINS ,HIGH/LOW DRINKING FOUNTAIN REVIEW COMMENTS PLANS EXAMINER REVIEW INCOMPLETE William Durden 5/6/2020 Comment: THE CHANGE OF OCCUPANCY TYPE SHALL SHOW COMPLIANCE WITH F.B.C. EXISTING AND WILL REQUIRE SIGNED SEALED PLANS FROM A FLORIDA LICENSED DESIGN PROFESSIONAL THAT INCLUDE BUT NOT LIMITED TO THE FOLLOWING ITEMS. 1. APPROVALS FROM THE HEALTH DEPARTMENT WILL BE REQUIRED AS APPLICABLE. 2. PROVIDE A DETAILED FLORIDA BUILDING CODE ANALYSIS FORM THE DESIGN PROFESSIONAL THAT INCLUDES BUT IS NOT LIMITED TO ALL APPLICABLE TO FLORIDA BUILDING CODES, NFPA CODES AND NEC CODES, OCCUPANT LOAD (INCLUDE EACH OCCUPANCY IN THE BUILDING AND SUBSEQUENT OCCUPANT LOADS FOR EACH), TYPE OF CONSTRUCTION, FIRE SEPARATION FROM OTHER OCCUPANCY TYPES, SPRINKLED OR NON -SPRINKLED, MIXED USES AND OCCUPANCY CLASSIFICATION, SPECIAL - OCCUPANCY TYPES, EXISTS REQUIRED AND EXISTS PROVIDED, EXIT SEPARATION, EXIT ACCESS TRAVEL DISTANCE ALLOWED AND PROVIDED, COMMON PATH OF EGRESS TRAVEL ALLOWED AND PROVIDED, CORRIDOR WIDTH REQUIRED AND CORRIDOR WIDTH'PROVIDED, EXIT WIDTH REQUIRED AND EXIT WIDTH PROVIDED AND PLUMBING FIXTURE COUNT REQUIRED AND PROVIDED. 3. THE WIND LOAD OF THE.BUILDING NEEDS TO BE ADDRESSED WHEN THE CHANGE OF OCCUPANCY PUTS THE STRUCTURE INTO A HIGHER RISK CATEGORY PER CHAPTER 16 OF THE F.B.C. 4 THE LIVE LOAD OF WOOD FLOORS AND STAIRS MUST COMPLY WITH THE REVISED USE OF THE BUILDING PER CHAPTER 16 OF THE F.B.C. 5. THE NEW OCCUPANCY MUST COMPLY WITH CHAPTER 9 OF THE F.B.C. FOR SPRINKLER SYSTEMS AND FIRE ALARMS WHEN APPLICABLE. 6. WIND BORNE DEBRIS PROTECTION WILL BE REQUIRED FOR GLAZED OPENINGS. . 7. THE NEW OCCUPANCY MUST COMPLY WITH CHAPTER 10 OF THE F.B.C. WHICH WILL INCLUDE BUT IS 5/6/2020 NOT LIMITED TO. A. ALL DOORS WILL BE REQUIRED TO PROVIDE 32" CLEAR OPENING MEASURED FROM THE DOOR OPENED 90 DEGREES TO THE DOOR STOP. B. CORRIDORS WILL BE REQUIRED TO COMPLY WITH FIRE RESISTANCE RATINGS AND WIDTH. C. STAIR TREADS AND RISER'S DIMENSIONS MUST COMPLY WITH THE F.B.C. REQUIREMENTS. D. GUARD RAIL HEIGHTS MUST COMPLY WITH THE F.B.C. E. TOILET ROOM MUST HAVE NONABSORBENT WALL SURFACES FOR A CERTAIN HEIGHT. 8.,THE NEW OCCUPANCY WILL REQUIRE COMPLIANCE WITH THE F.B.C. ACCESSIBILITY INCLUDING BUT NOT LIMITED TO A. AN ACCESSIBLE ROUTE FROM THE ACCESSIBLE PARKING TO THE STRUCTURE. B. ACCESSIBLE ENTRANCES AND EXIT AS REQUIRED BY THE F.B.C. ACCESSIBILITY THAT INCLUDE THE DOOR.OR DOORS. C. AN ACCESSIBLE ROUTE THROUGHOUT THE BUILDING INCLUDING THE MANEUVERING CLEARANCES REQUIRED AT THE DOORS. D. THE BATHROOMS WILL NEED TO BE ALTERED TO COMPLY WITH THE F.B.C. ACCESSIBILITY OR NEW ACCESSIBLE TOILET ROOMS CONSTRUCTED. E. MULTIPLE STORY STRUCTURES WILL NEED TO ADDRESS VERTICAL ACCESSIBILITY. 9. THE NEW OCCUPANCY WILL BE REQUIRED TO SHOW COMPLIANCE WITH THE F.B.C. MECHANICAL FOR VENTILATION. 10. THE NEW OCCUPANCY WILL REQUIRED TO SHOW COMPLIANCE WITH THE N.E.C. WHEN APPLICABLE.