Loading...
HomeMy WebLinkAboutFL digital 30x utility exp b revisedSTRUCTURAL DESIGN PARTIALLY ENCLOSED (UTILITY) BUILDING EXPOSURE B MAXIMUM 30'-0" WIDE X 20'-0" EAVE HEIGHT- BOX EAVE FRAME AND BOW FRAME 18 December 2017 Revision 1 M&A Project No. 16154SI17300S Prepared for: Tubular Building Systems, LLC 631 SE Industrial Circle Lake City, Florida 32025 Prepared by: Moore and Associates Engineering and Consulting, Inc. 1009 East Avenue North Augusta, SC 29841 SINE• S. ` Moo 401 S. Main Street Suite 200 . • �� SF•' Mount Airy, NC 27030 No 57170 Digitally signed byWayne S --n• �� STATE OF �� O•. <v: DateMoor 2017.12.19 MOORE ANO ASSOCIATES Cam_`,` 'q/ 13:16:08-05'00' eNGkIV6�FIING AND clarusut_TING " Ngi � This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. No 57170 *: :* STATE OF : �:. 4ctW� • rrrlrr� This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. MOORE AND ASSOCIATES DRAWN BY, LT 30'-O"x2o'-o° PARTIALLY ENCLOSED CNcpCeD BY, PDH ENGINEERING AND CONSULTING, INC. (UPFITY) BUILDING FFr B PROJECT NOR- WSH DATE: - B- 7 SCALE- NTS JOB N(� 1161:4S117300S THIS DDCU[Nf IS THE PMVUTY Cr HWK AND ASSOCIATES ENGINEERING AND CaamTlm THE LMUTHMIZED DEP4O0XII'll . COPTUE,, OR OTMMISE USC or THIS DOCIP[NT IS STRICTLY PDONIDITED AND ANT WRlNGENE10 THEDEIIPM NAY DE SUDJCCT TO LEGAL ACTION CL NT- TIPS T, r DWG NO 5K-2 Vf 1 DRAWING INDEX SHEET 1 PE SEAL COVER SHEET SHEET 2 DRAWING INDEX SHEET 3 INSTALLATION NOTES AND SPECIFICATIONS SHEET 4 TYPICAL SIDE AND END ELEVATIONS SHEET 5 TYPICAL RAFTER COLUMN END AND SIDE FRAMING SECTIONS (BOX EAVE RAFTER) SHEET GA TYPICAL RAFTER COLUMN CONNECTION DETAILS (LACED COLUMN) SHEET 6B TYPICAL RAFTER COLUMN CONNECTION DETAILS (DOUBLE COLUMN) SHEET 6C TYPICAL RAFTER COLUMN CONNECTION DETAILS (SINGLE COLUMN) SHEET 7 TYPICAL RAFTER COLUMN END AND SIDE FRAMING SECTIONS (BOW RAFTER) SHEET 8A TYPICAL RAFTER COLUMN C❑NNECTI❑N DETAILS (DOUBLE COLUMN) SHEET 8B TYPICAL RAFTER COLUMN C❑NNECTION DETAILS (SINGLE COLUMN) SHEET 9A BASE RAIL ANCHORAGE ❑PTI❑NS SHEET 913 OPTIONAL FOUNDATION ANCHORAGE SHEET 10 TYPICAL END WALL AND SIDE WALL OPENING FRAMING SECTIONS (BOX EAVE RAFTER) SHEET 11 TYPICAL END WALL AND SIDE WALL ❑PENING FRAMING SECTIONS (BOW RAFTER) SHEET 12 WALL OPENING DETAILS SHEET 13 LEAN-TO OPTIONS (BOX EAVE RAFTER) SHEET 14 LEAN-TO OPTIONS (BOW RAFTER) SHEET 15 VERTICAL R❑❑F/SIDING OPTION END AND SIDE ELEVATION AND SECTION SHEET 16 OPTIONAL DOOR HEADER MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. `E rI S- A40 ``��P�•'� c E N s ' 09F'% No 57170 STATE OF ' W This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" PARTIALLY ENCLOSED(UTiLITYi BUILDING EXP B JOB ND MT ci Irwr. Tnc 6HT. 2 IDV4 ND SK•2 kEVa 1 INSTALLATION NOTES AND SPECIFICATIONS I. DESIGN IS FOR A MAXIMUM 30'-0' WIDE x 20'-0' EAVE HEIGHT PARTIALLY ENCLOSED STRUCTURES. 2. DESIGN WAS DONE IN ACCORDANCE WITH THE 2017 FLORIDA BUILDING CODE (FBC) 6TH EDITION, 2012 INTERNATIONAL BUE-DING CODE (IBC), AND 2015 IBC 3. DESIGN LOADS ARE AS FOLLOWS A) DEAD LOAD = 15 PSF B) LIVE LOAD = 12 PSF C) GROUND SNOW LOAD = 10 PSF 4. LOW ULTIMATE WIND SPEED 105 TO 140 MPH (NOMINAL WIND SPEED 81 TO 108 MPH) MAXIMUM RAFTER/POST AND END POST SPACING = 50 FEET 5. HIGH ULTIMATE WIND SPEED 141 TO 170 MPH (NOMINAL WIND SPEED 109 TO 132 MPH) MAXIMUM RAFTER/POST AND END POST SPACING = 4.0 FEET. 6, LOW HAZARD RISK CATEGORY 1 (WIND) 7, WIND EXPOSURE CATEGORY B S. SPECIFICATIONS APPLICABLE TO 29 GAUGE METAL PANELS FASTENED DIRECTLY TO 2 1/2' x 2 1/2' - 14 GAUGE TUBE STEEh (TS) FRAMING MEMBERS FOR VERTICAL PANELS, 29 GAUGE METAL PANELS SHALL BE FASTENED TO 18 GAUGE HAT CHANNELS (UNLESS OTHERWISE NOTED) 9. AVERAGE FASTENER SPACING ON -CENTERS ALONG RAFTERS OR PURLINS, AND POSTS, INTERIOR = 9' OR END = 6'. (MAX) 10. FASTENERS CONSIST OF p12-14x3/4' SELF -DRILLING FASTENER (SDF), USE CONTROL SEAL WASHER WITH EXTERIOR FASTENERS SPECIFICATIONS APPLICABLE ONLY FOR MEAN ROOF HEIGHT OF 20 FEET OR LESS, AND ROOF SLOPES OF 14' (312 PITCH) OR LESS SPACING REQUIREMENTS FOR OTHER ROOF HEIGHTS AND/DR SLOPES MAY VARY. 11. GROUND ANCHORS SHALL BE INSTALLED THROUGH BASE RAIL WITHIN 6' OF EACH RAFTER COLUMN ALONG SIDES 12. GROUND ANCHORS (SOIL NAILS) CONSIST OF #4 REBAR W/ WELDED NUT x 30' LONG IN SUITABLE SOIL CONDITIONS MAY BE USED FOR LOW ( j 108 MPH NOMINAL) WIND SPEEDS ONLY OPTIONAL ANCHORAGE MAY BE USED IN SUITABLE SOILS AND MUST BE USE IN UNSUITABLE SOILS AS NOTED. 13, OPTIONAL BASE RAIL ANCHORAGE MAY BE USED FOR LOW AND MUST BE USED FOR HIGH WIND SPEEDS 14. WIND FORCES GOVERN OVER SEISMIC FORCES SEISMIC PARAMETERS ANALYZED ARE SOIL SITE CLASS = D RISK CATEGORY I/11/111 R= 3,25 IE= 1.0 SDS= 1.522 V= CSW SDI= 0.839 MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. S 11 M0 . P� O ., No 57170 r � r a O'.• STATE OF ��T111! This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-O"x20'-O" PARTIALLY ENCLOSED (UTILITY) BUILDING EXP. B THIS DOCUMEwT IS STRICTLY IIIIDITED wo ANY TttlltlKENE tT THEREUPON My K SMXCT TD LEGAL ACTIOt CLIENTP TBS ISHT. 3 JOW& RYA SK-2 —]BOX EAVE FRAME RAFTER ENCLOSED BUILDING ROLL -OP ODOR tAS APPLICABLE) DESIGN PRfSSUR[ LDV (IB5 PSF, -20.4 PSF) HIGH • t27.95 PSF, -30,7 PSr) DESIGN PRESSURE LCV • C208 PSF, -22.6 PSF) HIGH • (31.15 PSr, -31.15 PSr) FLASHING MAXIMUM RAFTER SPAN (W) ^I TYPICAL END ELEVATION -HORIZONTAL ROOF SCALE: NTS BOW FRAME RAFTER ENCLOSED BUILDING ROLL -UP DOM CAS APPLICABLE) SWINGING DOOR CAS APPLICABLE) DESIGN PRESSURE LOW • C185 Sr.P-204 PSF) DESIGN PRESSURE LOW • C20.B PSr, -22�6 PSF) HIGH • (27.95 PSF, -]ll-7 PSr) _ _ _ HIGH • (31-35 PSF, -](.15 PSr) FLASHING TYPICAL END ELEVATION SCALE NTS TYPICAL SIDE ELEVATION SCALE NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. WINCDV (AS APPLICABLE) DESIGN PRESSURE LOV • C210 PSF, -236 PSF) 14 1CH • (32.B5 PSF, -35.6 PSF) LENGTH VARIES DEPENDING ON NUMBER AND TYPICAL SIDE ELEVATION -HORIZONTAL ROO SCALE, NITS �•', I A4� `%'NeS.O 9!,�.. %+�..0ENs No 57170 'x � 0 • STATE OF 4/ i .O•40 A L E�� 111I1111 This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. T TUBULAR BUILDING SYSTEMS 30'-0"x2W-0" PARTIALLY ENCLOSED (UTILITY) PON BUILDING EXP, B JOB NOS MT IS STRICTLY lKMBITEC MR Uff IWRIWA)"T THDMIiEd PAT T. DV4 ND SK-2 VA I TO LEGAL ECTIaT GLIENT� TB5 29 GA. GALVANIZED METAL ROOF AA PANELS FASTENED TO RAFTERS AND u 24. 18 GA. U-CHANNEL BRACE FASTENED TO RAFTER WITH (4) 02-14-314* SDF'S AT EACH CND (B PER BRACE) 29 GA. GALVANIZED METAL ROOr PANELS FASTENED TO RAFTERS 24' 1B GA. u-CHANNEL BRACE FASTENED TO RAFTER WITH (4) 012-14.3/4' SDF'S AT EACH END (B PER BRACE) u TYPICAL RAFTER/COLUMN END FRAME SECTION TYPICAL RAFTER/COLUMN END FRAME SECTION SCALE, NTS 29 GA, GALVANIZED METAL RDDr An PANELS FASTENED TO RAFTERS AND 24' IS GA. U-CHANNEL BRACE FASTENED TO RAFTER WITH (4) ■12-14.3/4' SDF'S AT EACH END (B PER BRACE) SCALES NTS SEE NOTES (SHEET 3) FOR MAxiKim TYPICAL RAFTER/COLUMN END FRAME SECTION TYPICAL RAFTER/COLUMN SIDE FRAMING SECTION SCALE: NTS SCALE, NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. TO LEGAL ACTICK %0`�`�E S � `M �.��. �` �i i No 57170 yt; ;yt :-13 ' STATE QF AU This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS T 30'-0"x20'-0" PARTIALLY ENCLOSED (UTILITY) PLH BUILDING EXP B JOB NG 5 I01dCs NO SK-2 FEVa I TS ROOr RAFTER /f 3/16 CONNECTOR SLEEVE TO 3/16 RAFTER (TYP.) t MINIMUM 6' LONG, MINIMUM 15 GA., IS NIPPLE SECURE POST TO NIPPLE WITH (4) p �I ■12-14.3/4' SDr'S _I 6' I 3/16 TYP I 3/16 CHORD TS COLUMN I I BOX EAVE RAFTER COLUMN GHTS16NECTION DEAL WEI0'C TO i 20'-0- D�LR ;. A "s I 7L- LZN IB GA. U-CHANNEL BRACE FASTENED TO THE COLUMN AND ROOF BEAR, WITH (4) 412-14.3/4• SDr'S AT EACH END (B PER BRACE) BRACE SECTION SCALE NITS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. L SDF,S C WITH (4) 012_14.3/4• SDi'S (EACH END) 18 GA. U-CHANNEL BRACE S COLUMN MINIMUM 6' LONG, MIN[MU. 15 GA., TS NIPPLE SECURE WITH I41 Nt2-1CNMCCR 4w]/1' SDF'S 3+6tSLEEVETDO a I o' BASE RAIL TS CONTINUOUS e A BASE RAIL I! --ill 11=1lI--"-- RAFTER COLUMN/$ASE RAIL 2 CONNECTION DETAIL SCALE NTS 1111111 lot No 57170 �-0 :x O'.• STATE OF :I '*,'15f0NA; -- This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. T TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" PARTIALLY ENCLOSED (UTILITY) PON BUILDING EXP B JOB ND f11�.RCT TO C& �kTIOiI ...._ —. •._ IELIENh TBS _ ISHT. 6A JBVG Na SK•2 fIEW 1 SECURE VITH-----, (4) Y12-14.3/4• sor,s (EACH END) TS ROOF RAFTER CONNECTOR 3/16 12 SLEEVE TO RAFTER 3/16 3�"- (TYP.) e a o ° 6• �s• d w MINIMUM 6' LONG I MINIMUM 15 GA TS NIPPLE SECURE POST TO NIPPLE VITH (4) ale 14.3/41 sDr s 18 GA. W-CHANNEL BRACE 3-12 1 1 1 1 1 `TS DOABLE C.- -MN BOX EAVE RAFTER COLUMN CTION DETAI)ECA EIGHTS 14'-0' < TO i 16'-0'TS IB GA_ U-CHANNEL BRACE FASTENED TO THE COLUMN AND RDDr BEAM, VITH (4) r12-14.3/4• S➢r-S AT EACH 2 t/2• END to PER BRACE) L, 111 BRACE SECTION SCALE NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. 3_12 3-12 SLEEVE TO BASE RAIL a I a IS DOUBLE COLUMN MINIMUM 6' LONG, CONNECTOR SLEEVE MINIMUM 1S GA, SECURE WITH (4) •12-14.3/41 SDF'S e e TS CONTINUOUS BASE RAIL (DIAFTER COLUMN/BASE RAIL ONNECT'I'ON DETAIL SCALE w75 `E, S! i M No 57170 : t ' STATE OF &J •�iO��s�� O R , O P�; This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS W-0"xX-0" PARTIALLY ENCLOSED (UTILITY) BUILDING ExP B JOB ND I�IIuSio Iwo wT ptINGC10iT THEREUPON wr S{1�cTTOitKTO1 ICLIENT- TBS ISHT. 6D IDWG. ND SK-2 kV, 1 SECURE WITH (4) st2-14A/4' TS ROOF R►FtCR SDF'S (EACH END) CONNCCTDR 3/16 TS ROOF RAFTER SLEEVE 12 CONNECTOR 3/16 SLEEVE TO RAFTER 12 J� .• 7� TO RAFTER 3/16 7� 7/16 �r � I i O ��• SECURE WITH p e (4) 612-14.3/4• 0 6. SDF'S (EACH END) I � •L,4 6' MINIMUM 6' LONG, 4 MINIMUM 6' LUNG.-)•J• s MINIMUM 17 GA., TS NIPPLE- SECURE IB GA. U-CHANNEL BRACE MINIMUM 15 GA., TS NIPPLE SECURE I POST TO NIPPLE PpST Tp NIPPLE WITH (4) 212-14x3/4• SDF'$ WITH (4) N12-14x3/�' SDF•S TS COLUMN 0 IS CA. U-CHANNEL BRACE BOX EAVE RAFTER CO MN o ECTION�DEAILHEIGHT0'-0'TS COLUMN )�R #k NTS � d { e c a TS 2 1/4'.2 1/4-14 GA. :p 0 REINFORCING 6'-D' LONG tHV) m AND S'-D' LUNG (LW) It SECURE WITH LID) N12-14.7/4' m SDF'S 18 GA. U-CHANNEL BRACE FASTENED TO THE COLUMN AND ROOF BEAM. WITH (4) 012-14x3/4' SUPS AT EACH 0 END 08 PER BRACE) BRACE SECTION SCALE NTS BOX EAVE RAFTER COLUMN CONNECTION DETAIL FOR HEIGHTS 10'-0' < TO < 14'-0- 1 A SCALE NTS I Ts COLUMN If MINIMUM 6' LONG, CONNECTOR SLEEVE MINIMUM 16 GA., SECURE WITH (4) 012-14.3/4' SDF'S a TS CONTINUOUS BASE RAIL RAFTER COLUMN/BASE RAIL 2 CONNECTION DETAIL SCALE. NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. -*1��\6 .L.NSF�'9�'�. No 57170 O'.. STATE OF :1 ` i i �. This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" PARTIALLY ENCLOSED (UTILITY) BUILDING EXP. B JOB to 47 IS STRICTLY PRONISITED ANN A44T IWRl1VO4D T TIENUIPUN IUt �SNT. 6C IDVG NOSK»2 }iEV� I TO LEGAL ACTIOIL CLIENT= TBS 29 GA. GALVANIZED MCtAL ROOF AND WALI PANELS FASTENED TEI RAFTERS AND POSTS 24' 18 GA. U-CHANNEL BRACE FASTENED TO RAFTER WITH C4) I12-14.3/4' SDF'S AT EACH END C8 PER BRACE) TYPICAL RAFTER/COLUMN END FRAME SECTION SCALE: NITS SEE NOTES (SHEET 3) FOR MAXIMUM SPACING TYPICAL RAFTER/COLUMN SIDE FRAMING SECTION SCALE, wTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. 29 GA. GALVANIZED METAL ROOF AND WALL PANELS FASTENED TO RAFTERS AND POSTS Ct zr-' IB GA I1-CHANNEL ~, BRACE FASTENED TO RAFTER WITH (Q ol2-14.3/4' SDF'S Al EACH END (B PER BRACE) i h u TYPICAL RAFTER/COLUMN END FRAME SECTION SCALE I j"%E 1 ! rj rr�� Si ++ �N NO ., :• • No 57170 * �'.• STATE OF :��� 1111111101 This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x2O'-O" PARTIALLY ENCLOSED (UTILITY) BUILDING EXP. B JOB BID . 7 IDWG. Bo SK-2 JREw 1 SECURE WITH (4) N12-14.3/4' SDF'S (EACH END) TS BOW RAFTERla — 3 / N13 SCREWS REQUIRED IN SOv END A• / Qqd n C TS DOUBLE COLUMN 3.1{ MINIMUM 6• 'LONG, • CONNECTOR SLEEVE '' • / MINIMUM IS GA., IB GA, U-LHANNCL BRACE SLEEVE TO 3/16 SECURE WITH C47 BASE RAIL/3/16 o- MINIMUM 6' LONG, M[N[HUI( 15 GA., o o TS CONTINLflUS TS NIPPLE. SECURE BOW RAFTER AND BASE RAIL POST To NIPPLE WITH (4) 3-12 COLUUMGUN8LEI- 3-12 RAFTER COLUMN/BASE RAIL BOX SAVE RAFTER COLUMN 2 CONNECTION DETAIL SCALE: NTS DETAIL 010NNECT'ON R HEIGHTS 1�4'-D' < TO C 16'-D' SCALE. NTS m N IB GA. U-CHANNEL BRACE rASTENED TO THE COLUMN AND ROOF BEAM, WITH (4) 412-14'3/4' SMR.S AT EACH [—? 1/2' END (B PER BRACE) BRACE SECTION SCALE NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. S. A40 A•'� �E N s ' 09�'% No 57170 �� • STATE OF ' 4/ 40 �. i .O• //111111E This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. T TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" PARTIALLY ENCLOSED (UTILITY, PDw BUILDING EXP. B .JOB NDk rT IS STRICTILT PRDI4IRITER 00 MY INFRINGICKK TKREUPW IMT T. BA DWG NO, SK-2 Vs 1 TO LEGAL ACTIOL CLIENT- TBS BOW END f'1 D sCEukE WITH TS BOW RA 14I M12-l4,3/4' SOr'S (EACH END) IZ IS BOW RAFTER 3� NO SCREWS - RCDU[RED IN 3 BOW END 1B GA. U-CHANNEL BRACE `MINIMUM 6' LONG. MINIMUM 15 GA., TS NIPPLE. SECURE BOW RAFTER D ANp POST TO NIPPLE WITH (4) M12-14.3/4' SDCS TS D COLUMN —TS 2 1/4'.2 1/4'-14 GA. REINFORCING 6'-0' LONE (HW) ANp 5'-B' LONG (L Wr SECURE WITH (10) Mit-14.3/4' 0 S➢r S 0 BOX EAVE RAFTER COLUMN �NNECT ION DETAILIA R HEIGHTS 10'-0' < TO 14'-0' iTS COLUMN MINIMUM 6' LONG, SLEEVE TO 3/16 .-r.. CDNNCCTDrt SLEEVE BASE RAIL 7/16 0 MINIMUM IS GA., SECURE WITH (4) 012 14.314. SDP S D TS CONTINUOUS BASE RAIL R COLUMN/BASE RAILCTION R DETAIL>'S MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. MINIMUM 6' LONG, 1 MNIMUM IS 6A.. IS NIPPLE SECURE BOW RAFTER AND POST TO NIPPLE WITH (4) SECURE WITH (4) 412-14.3/4' S➢F'S (EACH END) IS GA. U-CHANNEL BRACE COLUMN BOX SAVE RAFTER COLUMN CONNECTION DETAIL 1 B FOR HEIGHTS c 10'-'0' SCALE, NTS m IB GA. U-CHANNEL BRACE FASTENED 70 THE COLUMN AND kDar BEAM. WITH (4) M12-14.3/4'SDF'S AT EACH END (8 PER BRACE) BRACE SECTION SCALE, NTS .``�yv\E 1 S `HMO �!%- .F' No 57170 STATE OF 10. ONA� This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. T TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" PARTIALLY ENCLOSED(UTILITY) — BUILDING EXP B Be IBWCL ND SK-2 JREEV, I BASE RAIL ANCHORAGE OPTIONS FOR LOW AND HIGH WIND SPEED WVF OR FIBERGLASS INSTALL 1/2'.6 V4' EXPANSION FIBERS ANCHOR THROUGH BASE RAIL W1TH]N 6. Or EACH POST . VARIES GRADE 9 a 4 =: MINIMUM ] I/ - EMBEDMENT 111- I ! • ^ I .1 I TYP.) _I E 1y li i MONOLITHIC CONCRETE FETINGI-- (3000 PSI MIN.) REINFORCED .I V1TH (2) 04'5 CONTINUOUS C(NCRETE MONOLITHIC SLAB 3A BASE ILA NCHORAGE (HINIHUM ANCHOR EDGE DISTANCE IS 4•) .COORDINATE WITH LOCAL CODES/ORD. 2' WASHERS DRILL 3/8' DIAMETER HOLE TOP pF ASPHALT THROUGH THE BASE RAIL AND PAVEMENT 0R SECURE TD ANCHOR EYE WITH GROUND SURFACC I/2' OIAMETCR THROUGH BOLT GENERAL NOTES CONCRETE - CONCRETE SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF 3,000 PSI AT 28 DAYS COVER OVER REINFORCING STEEL- FOR FOUNDATIONS, MINIMUM CONCRETE COVER OVER REINFORCING BARS SHALL BE PER ACI-318: 3 INCHES IN FOUNDATIONS WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH THE EARTH OR EXPOSED TO THE EARTH OR WEATHER, AND 1 1/2 INCHES ELSEWHERE. REINFORCING STEEL; THE TURNDOWN REINFORCING STEEL SHA„L BE ASTM A615 GRADE 60. THE SLAB REINFORCEMENT SHALL BE WELDED WIRE FABRIC MEETING ASTM A185 OR FIBERGLASS FIBER REINFORCEMENT REINFORCEMENT MAY BE BENT IN THE SHOP OR THE FIELD PROVIDED- I REINFORCEMENT IS BENT COLD 2 THE DIAMETER OF THE BEND, MEASURED ON THE INSIDE OF THE BAR, 1S NOT LESS THAN SIX -BAR DIAMETERS 3 REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT HELIX ANCHOR NOTES- I FOR VERY DENSE AND/OR CEMENTED SANDS, COARSE GRAVEL AND COBBLES, CALICHE, PRELOADED SILTS AND CLAYS USE MINIMUM (2) 4' HELICES WITH MINIMUM 30 INCH EMBEDMENT 2 FOR CORAL USE MINIMUM (2) 4' HELICES WITH MINIMUM 30 INCH EMBEDMENT 3 FOR MEDIUM DENSE COARSE SANDS, SANDY GRAVELS, VERY STIFF SILTS, AND CLAYS USE MINIMUM (2) 4' HELICES WITH MINIMUM 30 INCH EMBEDMENT 4 FOR LOOSE TO MEDIUM DENSE SANDS, FIRM TO STIFF CLAYS AND SILTS ALLUVIAL FILL USE MINIMUM (2) 6' HELICES WITH MINIMUM 50 INCH EMBEDMENT. 5 FOR VERY LOSE TO MEDIUM DENSE SANDS, FIRM TO STIFFER CLAYS AND SILTS, ALLUVIAL FILL USE MINIMUM (2) B' HELICES WITH MINIMUM 60 INCH EMBEDMENT. MOORS AND ASSOCIATES ENGINEERING AND CONSULTING, INC. I I- I I= I I El f! :: Ei I I-1' I=1 —I 11=1 I Ed I Fes! I d1 IS CONTINUOUS BASE RAIL HELIX EYE ANCHpR� (SEE NOTES BELOW) 3 B GROUND BASE HELIX ANCHORaGE SCALE NTS (CAN BE USED FOR ASPHALT) S. A40 ���y�Q�' •� G E lV s+ • 09���. No 57170 •xx � 0 ' STATE OF '4/ i A L E�� 11111 This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" PARTIALLY ENCLOSED (UTILITY) BUILDING EXP. B .JOB ND NIN 11"INGIDIENT TMERELKN WAY I cl 1cur. ree kHT. 9A JDWIG, NO- SK-2 OPTIONAL FOUNDATION ANCHORAGE FOR LOW & HIGH WIND SPEED INSTALL I/2'm ANCHOR ROB THROUGH BASC RAIL WWF OR FIBERGLASS POSiINSEC DCTAILN•L') FIBERS ttTP.) I•I 6 A A A ti. _ - MINIMUM 6' — EMBEDMENT f TTP,) I ? a -III"' MONOLlTH[L CONCRETE FOOTING (3000 PSI MIN) REINFORCED I�I. III! WITH (2) 04's CONTINUOUS CONCRETE MONOLITHIC SLAB 3A BASE RAIL ANCHORAGE SCALE NTS (M: IMUM ANCHOR EDGE DISTANCE 1S 1 1/2') ■ — ORDINATE WITH LOCAL CODES/ORD. GENERAL NOTES CONCRETE - CONCRETE SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF 3,000 PSI AT 28 DAYS COVER OVER REINFORCING STEEL: FOR FOUNDATIONS, MINIMUM CONCRETE COVER OVER REINFORCING BARS SHALL BE PER ACI-318. 3 INCHES IN FOUNDATIONS WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH THE EARTH OR EXPOSED TO THE EARTH OR WEATHER, AND 1 1/2 INCHES ELSEWHERE REINFORCING STEEL: THE TURNDOWN REINFORCING STEEL SHALL BE ASTM AG15 GRADE 60 THE SLAB REINFORCEMENT SHALL BE WELDED WIRE FABRIC MEETING ASTM A185 OR FIBERGLASS FIBER REINFORCEMENT. REINFORCEMENT MAY BE BENT IN THE SHOP OR THE FIELD PROVIDED: 1 REINFORCEMENT 1S BENT COLD. 2 THE DIAMETER OF THE BEND, MEASURED ON THE INSIDE OF BAR, IS NOT LESS THAN SIX -BAR DIAMETERS 3 REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL BE FIELD BENT. 0 a 1/2'P A36 THREADED ROD T/CONCRETE u .o = W ve ^4 HEAll, HEx NUT ANCHOR ROD THROUGH BASE 3C RAIL DETAIL SCA.'_ NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. MID wu Afr INSTALL 1/2•0 ANCHOR WWf OR ROD THROUGHpF BASE RAS� FIBERGLASS VITH[N 6' EACH FIBERS POST (SEE DETAIL 'C') (TYP.) (TYP.) MONOLITHIC CONCRETE F001 (3000 PSI MIN) RCINFORCEI WITH (a) 64's CONTINUOUS CONCRETE MONOLITHIC SLAB 3B BASE RAIL ANCHORAGE SCALE NITS (MINIMUM ANCHOR EDGE DISTANCE IS 1 !/2') ■ COORDINATE WITH LOCAL CODES/ORD. THE+,Vr�O NOT `♦♦���P'. �,� G.E.N SF•; i No 57170 �-0 O'.. STATE OF Imo` �� .O A 1. • r `� This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" PARTIALLY ENCLOSED (UTILITY) BUILDING EXP, B JOB to . 91111 IIWfi` NO; SK-2 BOX EAVE RAFTER END WALL AND SIDE WALL OPENINGS SEE NOTES TYPICAL BOX EAVE RAFTER END WALL FRAMING SECTION SCALE NTS SEE NOTES BOX EAVE RAFTER/COLUMN (SHEET ]) ASSEMBLY FOR MAXIMUM SPACING B 9 1 12 7 7 6 12 6 12 OPENING FOR t2 12 ROLL.0 DOOR WITH HEADER OPOPENING FOR WINDOW 12'-0' MAXIMUM [NIH4 FOSWINGING OR R WITH HEADER AND WITH HEADER WINDOW RAIL (ALSO 7 APPLICABLE tO END ID D 7 WALLS) 12 t2 9 12 SEE NOTES TYPICAL BOX EAVE RAFTER END WALL OPENINGS FRAMING SECTION TYPICAL BOX EAVE RAFTER SIDE WALL OPENINGS FRAMING SECTION SCALZ: HTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. .�`��� \e t S I', M(�!�.. No 57170 3 S TAT E OF : �4U #'If�rS �O N A` E 0 % This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x2O'-0" PARTIALLY ENCLOSED (UfILITY) BUILDING EXP. B JOB ND 10 loin. ilk Stt-2 BOW RAFTER END WALL AND SIDE WALL OPENINGS SEE NOTES TYPICAL BOX EAVE RAFTER END WALL FRAMING SECTION SCALE- Nl err umsre TYPICAL BOX EAVE RAFTER SIDE WALL OPENINGS FRAMING SECTION SCALE, NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. SEE NOTES TYPICAL BOX SAVE RAFTER END WALL OPENINGS FRAMING SECTION SCALE `+`,``NE IS. A40 ��,s, �`��P�•'�c EN*" 09F'% No 57170 - :1 ' STATE OF ' W This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x2d-0" PARTIALLY ENCLOSED (UTILITY) BUILDING EXP. B JOB ND HAT ti kHT. n lam � SK-2 r� �rur. roc BOW AND BOX EAVE RAFTER WALL OPENING DETAILS IS RAFTER 2'.2'.2' t6 GA. ANGLE CLIP SECURE TO COLUMN AND RAFTER WITH 412 14.3/A' SDr S 2 ON TIIP AND 2 ON SIDE TS END COLUMN IS COLUMN (CORNER) MINIMUM 6' LONG, MINIMUM 13 GA., IS NIPPLE SECURE WITH b41 a12-14s7//' SDF'S 16 GA. CLIP ANGLE NIPPLE TO 7/16 /II SECURE TO RAFTER COLUMN BASE RAIL AND BASE RAIL W/(U 3/l6 1t2-1{.7/{' SOr'S IS CILNT114UMJS BASE RAIL END COLUMN/RAFTER END COLUMN/BASE RAIL CONNECTION DETAIL 4 CTION DETAIL SCALE. NTS 5 )�SCALE TS iSTRUSSED RAFTER CHORD. OR HEADER 7-12 7/t6 HIPPIE TO .. ._ 3.12 7/t6 HEADER 2'.2'.2' 16 GA. ANGLE IS END COLUMN CLIP SECURE TO COLUMN (EACH SIDE) AND - -1— — - OR DOOR WINDOW FRAME POST RAFTER CHORD/RAIL WITH �t2-1{.3/{' SDCS - 2 ON BOTTOM AND 2 ON SIDE O MINIMUM 6' LONG, NOTE AT ROLL -UP DOOR MINIMUM 15 GA., TS NIPPLE SECURE EACH TS HEADER, BASE pPCNINGS. PAST SHOlILO ° ° WITH ({) M12-1{.7N' RAIL. OR WINDOW BE rLUSH WITH RAIL SDr'S RAIL END. CLIP POST TO IS COLUMN RAIL ONLY ON SIDE OPPOSITE THE DPENING. COLUMN TO HEADER, DOUBLE HEADER/COLUMN BASE RAIL, OR 8 CONNECTION DETAIL WINDOW RAIL scALE NTS 7 CONNECTION DETAIL SCALE NTS COLUMN I j�-NPIHUM 6• LONG, SIT,// MNIMUM l5 GA., IS ° NIPPLE. SECURE EACH WITH U) 412-1{.3/{' SDr's ° ° TS CON' BASE R- COLUMN/BASE RAIL 10 CONNECTION DETAIL $CAL£- NrS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. IS COLUMN 10 END COLUMN 2'.2'.2' 16 GA, ANGLE CLIP SECURE Tp COLUMN AND EITHER TOP Or HEADER, OR BOTTOM OF WINDOW RAIL WITH Al2-1{.3/{' SDr'S IT I `TS HEADER OR WINDOW RAIL HEADER OR WINDOW RAIL TO COLUMN 6 CONNECTION DETAIL SCALE- NTS IS COLUMN NIPPLE TD 7/16 HEADER 3/l6 MINIMUM 6' O MINIMUM 15 G� NIPPLE. SECL WITH ({) ° 012.14.7/4' S➢r'S `Is DOUBLE HEADER 7-12 COLUMN/DOUBLE HEADER 9 CONNECTION DETAIL SCALE NTS S 11 MO / O i1 No 57170 STATE OF ' �. .O• Ss,O N AL E���`• 11111111 This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS T 3Q'-0"x2Q'-O" PARTIALLY ENCLOSED (UTILITY) PI)H BUILDING EXP B JOB NO S DOCUKNT Ii STRICTLY PROHIBITED .RD AIR 11FRII1iEIOR THER ELIPIO+ MAY MT_ 12 BvC� ND SIC-2 V� ! SUD�ECT TO LCGAL A"JOL CLIENT, TB5 - BOX EAVE RAFTER LEAN-TO OPTIONS S, TYPICAL BOX EAVE RAFTER LEAN-TO OPTIONS FRAMING SECTION (BOTH OPTIONS SHOWN) SCALEt NTS MAXIMUM WIDTH OF SINGLE MEMBER RAFTER LEAN—TO IS 16'-01, TS BOX EAVE RAFTER NIPPLE 7D 3116 1 RAFTER 3/16 12' tONG TS l5 GA. / SECURE WITH NIPPLE. SECURE (4) 012.14.3/V SDF'S COLUMN TO NIPPLE LEACH END) WITH CO 412-14.3/4• 6. i o 10 GAU-CHANNEL BRACE IS EXTENSION RAFTER MINIMUM 6' LONG. MNMUM IS GA., TS NIPPLE SECURE COLUMN TO NIPPLE # WITH (4) M12-14'7/4' snr's / TS COLUMN 11 SIDE EXTENSION RAFTER/COLUMN DETAIL SCALE NTS MOORS AND ASSOCIATES ENGINEERING AND CONSULTING, INC. T 2'.2'.2' 16 GA. ANGLE CLIP SECURE TO COLUMN AND RAFTER WITH 112-14.3/4• SDF'S 2 ON TOP AND 2 ON Bottom rTS RAFTER COLUMN LEAN-TO RAFTER TO RAFTER 12 COLUMN CONNECTION DETAIL Srr�OO,,'' i No 57170 f STATE OF This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"xW-0" PARTIALLY ENCLOSED (UTILITY) BUILDING EXP. B .108 Nm THIS COCNICNT IS STRICTLY PMIUTCD MM ANT 111FRINGENO" THERIOPON MAY K SULIECT TO LCGAL ACTION CLIENTa TBS T. 13 OY11 NO SK-2 BOW RAFTER LEAN-TO OPTIONS TYPICAL BOW RAFTER LEAN—TO OPTIONS FRAMING SECTION (BOTH OPTIONS SHOWN) SCALE, NTS MAXIMUM WIDTH OF SINGLE MEMBER RAFTER LEAN-TO IS 16'-0' NO SCREWS- REOUIRED IN BOW END 2'.2'.2. M GA. ANGLE—� CLIP SECURE TO CCLUMN AND RAFTER WITH Al2-14.3/4' SDF'S 2 ON TOP AND 2 pN BOTTOM TS RAFTER SECURE VITH (4) •72-6M.3/� snr'S (EACH ENO7 IS BOW RAFTER l2 Q,a/L f ,'3. :.c / IS GA. U-CHANNEL BRACE "'--IS COLUNN 13 SIDE EXTENSION RAFTER/COLUMN DETAIL SCALE NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. NEISII1[40o e" I No 57170 V • • �L r O'.. STATE OF :� This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" PARTIALLY ENCLOSED (UTILITY) BUILDING EXP B JOB ND 14 I➢VG. NOS SK-Z IREVa l BOX EAVE RAFTER VERTICAL ROOFISIDING OPTION 29 GA, GALVANIZED METAL ROOF PANELS FASTENED TO PURLINS WITH 412-140/4' SDF'S FLASHING TYPICAL END ELEVATION VERTICAL ROOF/SIDING OPTION SCALE: NTS FLASHING TYPICAL SIDE ELEVATION VERTICAL ROOF/SIDING OPTION SCALE, NTS ROOF PANEL ATTACHMENT (ALTERNATE FOR VERTICAL ROOF PANELS? SCALE: NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. 15-I8 GAUGE FURRING CHANNEL (PURL IN, TYPICAL SECTION VERTICAL ROOF/SIDING OPTION SCALE, NTS SEE NOTES L5--19 GAUGE FURRING CHANNEL SPACED (SHEET 3) NOT MORE THAN 4'-0' aC AND FASTENED FOR MAXIMUM TO EACH RArTER WITH (2) M12-14.3/4' SPACING /f SLr•S TYPICAL FRAMING SECTION VERTICAL ROOF/SIDING OPTION SCALE NTS .0` Ae I S A4 .� yN o �. �•`�P .•`G'E N s • 09��.. No 57170 f STATE OF .' Q This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'•0"x20'-0" PARTIALLY ENCLOSED (UTILITY) BUILDING EXP B JOB HO: PST Irn trur. roe kHT. 15 Im. to SK-2