HomeMy WebLinkAboutDesign Pressure for Wall ComponentsCompany: The Home Depot at Home Services Job Description: Windows Prepared By: Richie Roberts Client Name: Durso Project Number: 7256980 DESIGN PRESSURES FOR WALL COMPONENTS & CLADDING Design Data Building Data Wind Velocity (mph) 180 Mean Roof Height 12 Risk Category 2 Building Width (ft) 42 Exposure Category C Building Length (ft) 43 Directionality Factor 0.85 Roof Slope (x:12) 4 Internal Pressure Coefficient+1- 0.18 Design pressures listed below are: Allowable Stress OPENING MARK 1 2 OPENING DESCRIPTION 6100 DH 6100 DH LOCATION ZONE 4 5 OPENING ELEVATION 5 5 OPENING DIMENSIONS WIDTH (INCHES) HEIGHT (INCHES) 36 38 36 38 MAXIMUM POSITIVE PERSSURE (PSF) 29.4 29.4 MAXIMUM NEGATIVE PRESSURE (PSF) -31.9 -39.4 i i i STRUCTURES tNTOWATIONAL, LLC ate, Width of End Zone (a) in feet = 4.2 ft FILE " ° �:dY Qu 11/27/2013 9:51 AM