Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutjb_349228_00_b_acad_b_01ABBREVIATIONS
REV BY DATE COMMENTS
REV A NAME DATE COMMENTS
****
****
****
****
ELECTRICAL NOTES
GENERAL NOTES
Front Of House
2
4
"
F
S
B
2
4
"
F
S
B
24"
F
S
B
24"
F
S
B
2
4
"
F
S
B
2
4
"
F
S
B
2
4
"
F
S
B
2
4
"
F
S
B
24"
F
S
B
2
4
"
F
S
B
SV
(E) DRIVEWAY
SV
LEGEND
Scale: 3/32" = 1'
SITE PLAN
0 1'10'21'
#SSTAMPCA
#ESTAMPCA
MP1
23
89
23
89
Comp Shingle 2 Stories
MP2
23
269
23
269
Comp Shingle 2 Stories
Scale: 1 1/2" = 1'
STANDOFFS1
NTS
TYPICAL PV SIDE VIEWSV
#SSTAMPCA
#SSTAMPCA
LICENSEGENERAL NOTESMAIN PANEL SPECSGROUND SPECS
AC
N
A
B
EGC/GEC
GEC
Z
5 Y
4
N
EGC
L2
L13
X
N
EGC
L2
L13
X
3
4
5
POI
Z
Y
X
#ESTAMPCA
Inverter 1
Voc*= VDC Isc = ADC
Vmp = VDC Imp= ADC1
MODULE SPECSINVERTER SPECSGROUND SPECS
AC DC
V240
L2
L1
N
EGC
GND
N
DC+
EGC
DC-
1
2
A
A
EGC
DC-
DC+
Vmp = VAC Imp= AAC
2
#ESTAMPCA
CAUTION
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE
FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN:
- Address: 15001 W Angle Rd
OPERATING VOLTAGE = 240V JB-349228-00
Battery storage utilized at this facility.
LB-130089-10X
Per Code:
NEC 690.31.G.3
Label Location:
(C)(CB)(JB)
LB-050081-10X
Per Code:
NEC 690.13.B
Label Location:
(DC) (INV)
LB-030042-10X
Per Code:
NEC 690.53
Label Location:
(DC) (INV)
LB-070004-10X
Per Code:
690.41.B
Label Location:
(DC) (INV)
LB-010001-10X
Per Code:
CEC 690.13.B
Label Location:
(DC) (CB)
LB-050082-10X
Per Code:
NEC 690.13.B
Label Location:
(AC) (POI)
LB-040007-10X
Per Code:
NEC 690.54
Label Location:
(AC) (POI)
LB-070005-10X
Per Code:
NEC 690.13.B
Label Location:
(AC)(POI)
LB-060046-10X
Per Code:
CEC 690.13.B
Label Location:
(POI)
LB-040009-10X
Per Code:
NEC 705.12.B.3
Label Location:
(POI)
LB-040008-10X
Per Code:
NEC 690.64.B.4
Label Location:
(D) (POI)
LB-070039-10X
Per Code:
NEC 705.12.B.2.3.b
Label Location:
(POI)
LB-070016-10X Label Location:
(DC) (INV)
(POI): Point of Interconnection
(M): Utility Meter
(LC): Load Center
(INV): Inverter With Integrated DC Disconnect
(IC): Interior Run Conduit
(DC): DC Disconnect
(D): Distribution Panel
(CB): Combiner Box
(C): Conduit
(AC): AC Disconnect
Label Set
LB-040137-10X
Per Code:
NEC 408.4
Label Location:
(BLC)
LB-040144-10X
Per Code:
NEC 220
Label Location:
(BLC)
LB-200025-10X
Per Code:
NEC 312.8.A(3)
Label Location:
(MP)
LB-030142-10X
Per Code:
NEC 705.12(B)(3)
Label Location:
(MP)
LB-040141-10X
Per Code:
Label Location:
(MP)
LB-040139-10X
Per Code:
Label Location:
(MP)
LB-040140-10X
Per Code:
Label Location:
(MP)
LB-040138-10X
Per Code:
Label Location:
(MP)
LB-200011-10X
Per Code:
NEC 705.12(B)(3)
Label Location:
(MP)
LB_200127_10X
Per Code:
NEC 705.12.B.2.3.c
Label Location:
(MP)
LB-200110-10X
Per Code:
Per 706.7(D) label to be marked in field
Label Location:
(MP)
(MP): Main Panel
(BLC): Backup Load Center
(AC): AC Disconnect
Label Set
TESLA.COM/ENERGY
POWERWALL
Tesla Powerwall is a fully-integrated AC battery system for
residential or light commercial use. Its rechargeable lithium-ion
battery pack provides energy storage for solar self-consumption,
time-based control, and backup.
Powerwall’s electrical interface provides a simple connection to
any home or building. Its revolutionary compact design achieves
market-leading energy density and is easy to install, enabling
owners to quickly realize the benefits of reliable, clean power.
PERFORMANCE SPECIFICATIONS
AC Voltage (Nominal)120/240 V
Feed-In Type Split Phase
Grid Frequency 60 Hz
Total Energy1 14 kWh
Usable Energy1 13.5 kWh
Real Power, max continuous2 5 kW (charge and discharge)
Real Power, peak (10 s, off-grid/backup)2 7 kW (charge and discharge)
Apparent Power, max continuous 5.8 kVA (charge and discharge)
Apparent Power, peak (10 s, off-grid/backup)7.2 kVA (charge and discharge)
Maximum Supply Fault Current 10 kA
Maximum Output Fault Current 32 A
Overcurrent Protection Device 30 A
Imbalance for Split-Phase Loads 100%
Power Factor Output Range +/– 1.0 adjustable
Power Factor Range (full-rated power)+/– 0.85
Internal Battery DC Voltage 50 V
Round Trip Efficiency1,3 90%
Warranty 10 years ENVIRONMENTAL SPECIFICATIONS
Operating Temperature –20°C to 50°C (–4°F to 122°F)
Recommended Temperature 0°C to 30°C (32°F to 86°F)
Operating Humidity (RH)Up to 100%, condensing
Storage Conditions –20°C to 30°C (–4°F to 86°F)
Up to 95% RH, non-condensing
State of Energy (SoE): 25% initial
Maximum Elevation 3000 m (9843 ft)
Environment Indoor and outdoor rated
Enclosure Type NEMA 3R
Ingress Rating IP67 (Battery & Power Electronics)
IP56 (Wiring Compartment)
Wet Location Rating Yes
Noise Level @ 1m < 40 dBA at 30°C (86°F)
MECHANICAL SPECIFICATIONS
Dimensions1 1150 mm x 753 mm x 147 mm
(45.3 in x 29.6 in x 5.75 in)
Weight1 114 kg (251.3 lbs)
Mounting options Floor or wall mount
1 Dimensions and weight differ slightly if manufactured before March 2019.
1 Values provided for 25°C (77°F), 3.3 kW charge/discharge power.
2 In Backup mode, grid charge power is limited to 3.3 kW.
3 AC to battery to AC, at beginning of life.
COMPLIANCE INFORMATION
Certifications UL 1642, UL 1741, UL 1973,
UL 9540, IEEE 1547, UN 38.3
Grid Connection Worldwide Compatibility
Emissions FCC Part 15 Class B, ICES 003
Environmental RoHS Directive 2011/65/EU
Seismic AC156, IEEE 693-2005 (high)
753 mm
(29.6 in)
147 mm
(5.75 in)
1150 mm
(45.3 in)
Contact Tesla for additional information.
TESLA.COM/ENERGY
TYPICAL SYSTEM LAYOUTS
PARTIAL HOME BACKUP
WHOLE HOME BACKUP
Main panelSub panel
Solar
Home loads
Solar inverter
Utility meter GridBackup Gateway
Powerwall Backup loads
Optional
NA - BACKUP - 2019-06-11
Utility meter Grid
Backup Gateway
including
service disconnect
Main panel
Solar
Whole home
backup
Solar inverter
Powerwall
Optional
ST
R
I
N
G
O
P
T
I
M
I
Z
E
R
String Optimizer
SO5000
Cost Effective PV power optimization at the string level
Connects to a string of modules, providing string Maximum Power Point Tracking (MPPT) while maintaining superior
ĞĸĐŝĞŶĐLJ;ϵϵ͘ϭйͿ
ŽŵƉĂƟďůĞǁŝƚŚ^ŽůĂƌĚŐĞƐŝŶŐůĞƉŚĂƐĞŝŶǀĞƌƚĞƌƐ
&ĂƐƚŝŶƐƚĂůůĂƟŽŶǁŝƚŚĂƐŝŶŐůĞďŽůƚ
EĞdžƚŐĞŶĞƌĂƟŽŶŵĂŝŶƚĞŶĂŶĐĞǁŝƚŚŽƉƟŵŝnjĞƌͲůĞǀĞůŵŽŶŝƚŽƌŝŶŐ
^ĂĨĞƚLJǀŽůƚĂŐĞŽƵƚƉƵƚ;чϮϱsͿĨŽƌŝŶƐƚĂůůĞƌĂŶĚĮƌĞĮŐŚƚĞƌƐĂĨĞƚLJ
ǁǁǁ͘ƐŽůĂƌĞĚŐĞ͘ƵƐ
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE
are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein
are trademarks of their respective owners. Date: 04/2018/V01/ENG NA. Subject to change without notice.
SO5000
INPUT
Rated Input DC Power;ϭͿ ϱϬϬϬ W
ďƐŽůƵƚĞDĂdžŝŵƵŵ/ŶƉƵƚsŽůƚĂŐĞ
;sŽĐĂƚůŽǁĞƐƚƚĞŵƉĞƌĂƚƵƌĞͿ ϲϬϬ sĚĐ
DWWdKƉĞƌĂƟŶŐZĂŶŐĞ ϭϮϬͲϱϯϬ sĚĐ
DĂdžŝŵƵŵ^ŚŽƌƚŝƌĐƵŝƚƵƌƌĞŶƚ;/ƐĐͿŽĨ
ĐŽŶŶĞĐƚĞĚWsDŽĚƵůĞ ϭϮ͘ϱ Adc
Maximum DC Input Current ϭϯ Adc
DĂdžŝŵƵŵĸĐŝĞŶĐLJ ϵϵ͘ϭ й
tĞŝŐŚƚĞĚĸĐŝĞŶĐLJ ϵϵ й
KǀĞƌǀŽůƚĂŐĞĂƚĞŐŽƌLJII
KhdWhdhZ/E'KWZd/KEΈ^dZ/E'KWd/D/ZKEEddKKWZd/E'/EsZdZΉ
Maximum Output Current ϭϮ͘ϱ Adc
DĂdžŝŵƵŵKƵƚƉƵƚsŽůƚĂŐĞ ϱϬϬs
KƉĞƌĂƟŶŐKƵƚƉƵƚsŽůƚĂŐĞƌĂŶŐĞ ϯϮϱͲϰϱϬ sĚĐ
KhdWhdhZ/E'^dEzΈ^dZ/E'KWd/D/Z/^KEEd&ZKD/EsZdZKZ/EsZdZK&&Ή
^ĂĨĞƚLJKƵƚƉƵƚsŽůƚĂŐĞƉĞƌ^ƚƌŝŶŐKƉƟŵŝnjĞƌ Ϯϱ sĚĐ
^dEZKDW>/E
D &WĂƌƚϭϱůĂƐƐ͕ϲϭϬϬϬͲϲͲϮ͕ϲϭϬϬϬͲϲͲϯ
^ĂĨĞƚLJ ϲϮϭϬϵͲϭ;ĐůĂƐƐ//ƐĂĨĞƚLJͿ͕h>ϭϳϰϭ
ZŽ,^Yes
ƌĐĞƚĞĐƟŽŶ;tŚĞŶŽŶŶĞĐƚĞĚƚŽ
^ŽůĂƌĚŐĞ/ŶǀĞƌƚĞƌͿ h>ϭϲϵϵ͖EϲϵϬ͘ϭϭ
ZĂƉŝĚ^ŚƵƚĚŽǁŶ;tŚĞŶŽŶŶĞĐƚĞĚƚŽ
^ŽůĂƌĚŐĞ/ŶǀĞƌƚĞƌͿ EϲϵϬ͘ϭϮ
/E^d>>d/KE^W/&/d/KE^
DĂdžŝŵƵŵůůŽǁĞĚ^LJƐƚĞŵsŽůƚĂŐĞ ϲϬϬ sĚĐ
ŝŵĞŶƐŝŽŶƐ;tdž>dž,Ϳ͕ǁŝƚŚŽƵƚďƌĂĐŬĞƚ ϭϴϲdžϮϬϬdžϳϭͬϳ͘ϯϮdžϳ͘ϴϳdžϮ͘ϴ ŵŵͬŝŶ
tĞŝŐŚƚ;ŝŶĐůƵĚŝŶŐĐĂďůĞƐͿ ϯ͘ϲͬϴ ŬŐͬůď
/ŶƉƵƚĂŶĚKƵƚƉƵƚtŝƌĞdLJƉĞͬŽŶŶĞĐƚŽƌ ŽƵďůĞŝŶƐƵůĂƚĞĚ͖ϰŵŵϮ;DϰͿ
/ŶƉƵƚtŝƌĞ>ĞŶŐƚŚ ϭϱϬͬϲ ŵŵͬŝŶ
KƵƚƉƵƚtŝƌĞ>ĞŶŐƚŚ ;&ĞŵĂůĞͿϴϬϬͬϯϭ͘ϱ͕;DĂůĞͿϵϬϬͬϯϱ͘ϰ ŵŵͬŝŶ
KƉĞƌĂƟŶŐdĞŵƉĞƌĂƚƵƌĞZĂŶŐĞ;ϮͿ ͲϰϬͲнϴϱͬͲϰϬͲнϭϴϱ ȗͬǑ&
WƌŽƚĞĐƟŽŶZĂƟŶŐ EDϲ
ZĞůĂƟǀĞ,ƵŵŝĚŝƚLJ ϬͲϭϬϬ й
ZĞǀĞƌƐĞĐƵƌƌĞŶƚƉƌŽƚĞĐƟŽŶ ϰϬ A
String Optimizer
SO5000
;ϭͿZĂƚĞĚ^dƉŽǁĞƌŽĨƚŚĞŵŽĚƵůĞ͘DŽĚƵůĞŽĨƵƉƚŽнϱйƉŽǁĞƌƚŽůĞƌĂŶĐĞŝƐĂůůŽǁĞĚ͘
;ϮͿWŽǁĞƌĚĞͲƌĂƟŶŐĨƌŽŵнϭϱϴǑ&ͬнϳϬϬ͘
;ϭͿZĞĨĞƌƚŽŝŶǀĞƌƚĞƌĚĂƚĂƐŚĞĞƚƐ͘
Ws^z^dD^/'E ,ͳts^ϯϬϬϬ,ͳ
h^ͳ^ϯϴϬϬ,ͳh^
,ͳts^ϱϬϬϬ,ͳ
h^ͳ^ϳϲϬϬ,ͳh^
^ϱϬϬϬͳh^ͳ
^ϳϲϬϬͳh^
^ϭϬϬϬϬͳh^ͳ
^ϭϭϰϬϬͳh^
DĂdžŝŵƵŵ/ŶƉƵƚ^ƚƌŝŶŐƉĞƌKƉƟŵŝnjĞƌ Ϯ
DŝŶη^ƚƌŝŶŐKƉƟŵŝnjĞƌƐƉĞƌ/ŶǀĞƌƚĞƌ ϭ Ϯ Ϯ Ϯ
DĂdžη^ƚƌŝŶŐKƉƟŵŝnjĞƌƐƉĞƌ/ŶǀĞƌƚĞƌ Ϯ ϰ ϰ 6
DĂdžŝŵƵŵWŽǁĞƌƉĞƌ^ƚƌŝŶŐKƉƟŵŝnjĞƌ ϱϬϬϬt͖ĚŽŶŽƚĞdžĐĞĞĚŝŶǀĞƌƚĞƌDĂdžŝŵƵŵWŽǁĞƌ;ϭͿ
^ƚƌŝŶŐƐŽĨŝīĞƌĞŶƚ>ĞŶŐƚŚƐĂŶĚKƌŝĞŶƚĂƟŽŶƐ Yes
I
N
V
E
R
T
E
R
S
solaredge.com
Optimized installation with HD-Wave technology
6SHFLÀFDOO\GHVLJQHGWRZRUNZLWK
SRZHURSWLPL]HUV
%XLOWLQPRGXOHOHYHOPRQLWRULQJ
2XWGRRUDQGLQGRRULQVWDOODWLRQ
2SWLRQDO5HYHQXHJUDGHGDWD$16,&
&ODVVDFFXUDF\
5HFRUGEUHDNLQJHFLHQF\
4XLFNDQGHDV\LQYHUWHUFRPPLVVLRQLQJGLUHFWO\
IURPDVPDUWSKRQHXVLQJWKH6RODU(GJH6HW$SS
)L[HGYROWDJHLQYHUWHUIRUORQJHUVWULQJV
8/6$FHUWLÀHGIRU&38&5XOHJULGFRPSOLDQFH
,QWHJUDWHGDUFIDXOWSURWHFWLRQDQGUDSLG
VKXWGRZQIRU1(&DQGSHUDUWLFOH
DQG
([WUHPHO\VPDOO
Single Phase Inverter
with HD-Wave Technology
for North America
6(+866(+866(+866(+86
6(+866(+866(+86
12-25
YEARWARRANTY
SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US
APPLICABLE TO INVERTERS WITH
PART NUMBER SEXXXXH-XXXXXBXX4
OUTPUT
Rated AC Power Output 3000 3800 @ 240V
3300 @ 208V 5000 6000 @ 240V
5000 @ 208V 7600 10000
11400 @ 240V
10000 @ 208V VA
Maximum AC Power Output 3000 3800 @ 240V
3300 @ 208V 5000 6000 @ 240V
5000 @ 208V 7600 10000
11400 @ 240V
10000 @ 208V VA
AC Output Voltage Min.-Nom.-Max.
(211 - 240 - 264)9999999Vac
AC Output Voltage Min.-Nom.-Max.
(183 - 208 - 229)-9 -9 --9 Vac
AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz
Maximum Continuous Output
Current @240V 12.5 16 21 25 32 42 47.5 A
Maximum Continuous Output
Current @208V -16-24- -48.5A
Power Factor DGMXᐎDEOHWR
GFDI Threshold 1 A
Utility Monitoring, Islanding
3URWHFWLRQ&RXQWU\&RQÀJXUDEOH
Thresholds
Yes
INPUT
Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W
Maximum DC Power @208V - 5100 - 7750 - - 15500 W
Transformer-less, Ungrounded Yes
Maximum Input Voltage 480 Vdc
Nominal DC Input Voltage 380 400 Vdc
Maximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 Adc
Maximum Input Current @208V(2)-9-13.5--27Adc
Max. Input Short Circuit Current 45 Adc
Reverse-Polarity Protection Yes
Ground-Fault Isolation Detection 600k Sensitivity
0D[LPXP,QYHUWHU(FLHQF\99 99.2 %
&(&:HLJKWHG(FLHQF\99 99 @ 240V
98.5 @ 208V %
Nighttime Power Consumption < 2.5 W
(1) For other regional settings please contact SolarEdge support
(2)$KLJKHUFXUUHQWVRXUFHPD\EHXVHGWKHLQYHUWHUZLOOOLPLWLWVLQSXWFXUUHQWWRWKHYDOXHVᐎDWHG
Single Phase Inverterwith HD-Wave Technology for North America
6(+866(+866(+866(+86
6(+866(+866(+86
SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US
ADDITIONAL FEATURES
Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional)
Revenue Grade Data, ANSI C12.20 Optional
(3)
Inverter Commissioning ZLWKWKH6HW$SSPRELOHDSSOLFDWLRQXVLQJEXLOWLQ:L)LᐎDWLRQIRUORFDOFRQQHFWLRQ
Rapid Shutdown - NEC 2014 and
2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect
STANDARD COMPLIANCE
Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07
Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI)
Emissions FCC Part 15 Class B
INSTALLATION SPECIFICATIONS
AC Output Conduit Size / AWG
Range 3/4” minimum / 14-6 AWG 3/4” minimum /14-4 AWG
DC Input Conduit Size / # of Strings /
AWG Range µPLQLPXPᐎULQJV$:* µPLQLPXPᐎULQJV$:*
Dimensions with Safety Switch
(HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in /
mm
Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 OENJ
Noise < 25 <50 dBA
Cooling Natural Convection
Operating Temperature Range -40 to +140 / -40 to +60(4)Ü)Ü&
Protection Rating NEMA 4X (Inverter with Safety Switch)
(3) Revenue grade inverter P/N: SExxxxH-US000BNC4
(4))XOOSRZHUXSWRDWOHDᐎÜ&Ü)IRUSRZHUGHUDWLQJLQIRUPDWLRQUHIHUWRKWWSVZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVVHWHPSHUDWXUHGHUDWLQJQRWHQDSGI
Single Phase Inverterwith HD-Wave Technology for North America
6(+866(+866(+866(+86
6(+866(+866(+86
6RODU(GJH7HFKQRORJLHV,QF$OOULJKWVUHVHUYHG62/$5('*(WKH6RODU(GJHORJR237,0,=('%<62/$5('*(DUHWUDGHPDUNVRUUHJLVWHUHGWUDGHPDUNVRI6RODU(GJH7HFKQRORJLHV,QF$OO
RWKHUWUDGHPDUNVPHQWLRQHGKHUHLQDUHWUDGHPDUNVRIWKHLUUHVSHFWLYHRZQHUV'DWH9(1*1$06XEMHFWWRFKDQJHZLWKRXWQRWLFH
TESLA.COM/ENERGY
Backup Gateway 2
POWERWALL
660
411 149
The Backup Gateway 2 for Tesla Powerwall provides energy management
and monitoring for solar self-consumption, time-based control, and backup.
The Backup Gateway 2 controls connection to the grid, automatically
detecting outages and providing a seamless transition to backup power.
When equipped with a main circuit breaker, the Backup Gateway 2 can be
installed at the service entrance. When the optional internal panelboard is
installed, the Backup Gateway 2 can also function as a load center.
The Backup Gateway 2 communicates directly with Powerwall, allowing you
to monitor energy use and manage backup energy reserves from any mobile
device with the Tesla app.
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature –20°C to 50°C (–4°F to 122°F)
Operating Humidity (RH)Up to 100%, condensing
Maximum Elevation 3000 m (9843 ft)
Environment Indoor and outdoor rated
Enclosure Type NEMA 3R
PERFORMANCE SPECIFICATIONS
AC Voltage (Nominal)120/240V
Feed-In Type Split Phase
Grid Frequency 60 Hz
Current Rating 200 A
Maximum Input Short Circuit Current 10 kA1
Overcurrent Protection Device 100-200A; Service Entrance Rated1
Overvoltage Category Category IV
AC Meter Revenue accurate (+/– 0.2 %)
Primary Connectivity Ethernet, Wi-Fi
Secondary Connectivity Cellular (3G, LTE/4G)2
User Interface Tesla App
Operating Modes Support for solar self-consumption,
time-based control, backup, and
off-grid
Backup Transition Automatic disconnect for seamless
backup
Modularity Supports up to 10 AC-coupled
Powerwalls
Optional Internal Panelboard 200A 6-space / 12 circuit Eaton
BR Circuit Breakers
Warranty 10 years
COMPLIANCE INFORMATION
Certifications UL 67, UL 869A, UL 916, UL 1741 PCS
CSA 22.2 0.19, CSA 22.2 205
Emissions FCC Part 15, ICES 003
NA 2020-05-23
1 When protected by Class J fuses, Backup Gateway 2 is suitable for use in
circuits capable of delivering not more than 22kA symmetrical amperes.
2 The customer is expected to provide internet connectivity for Backup Gateway
2; cellular should not be used as the primary mode of connectivity. Cellular
connectivity subject to network operator service coverage and signal strength.
MECHANICAL SPECIFICATIONS
Dimensions 660 mm x 411 mm x 149 mm
(26 in x 16 in x 6 in)
Weight 20.4 kg (45 lb)
Mounting options Wall mount, Semi-flush mount
YIELD SECURITY
ANTI PID TECHNOLOGY
(APT)
HOT-SPOT PROTECT
(HSP)
TRACEABLE QUALITY
(TRA.QTM)
ANTI LID TECHNOLOGY
(ALT)
Product and
Performance
Warranty
Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY
Higher yield per surface area, lower BOS costs, higher
power classes, and an efficiency rate of up to 19.5 %.
INNOVATIVE ALL-WEATHER TECHNOLOGY
Optimal yields, whatever the weather with
excellent low-light and temperature behavior.
ENDURING HIGH PERFORMANCE
Long-term yield security with Anti LID and Anti PID Technology1,
Hot-Spot Protect and Traceable Quality Tra.Q™.
ZEP COMPATIBLETM FRAME DESIGN
High-tech black Zep CompatibleTM frame, for improved aesthetics,
easy installation and increased safety.
A RELIABLE INVESTMENT
Inclusive 25-year product warranty and 25-year
linear performance warranty2.
STATE OF THE ART MODULE TECHNOLOGY
Q.ANTUM DUO combines cutting edge cell separation
and innovative wiring with Q.ANTUM Technology.
1 APT test conditions according to IEC/TS 62804-1:2015, method B (−1500 V, 168 h)
2 See data sheet on rear for further information
THE IDEAL SOLUTION FOR:
Rooftop arrays on
commercial and
industrial buildings
Q.PEAK DUO BLK-G6+ / SC
330-345
ENDURING HIGH
PERFORMANCE
Į [% / K] + 0.04 ȕ [% / K] − 0.27
Ȗ [% / K] − 0.36 NMOT [°F] 109 ± 5.4 (43 ± 3 °C)
330 335 340 345
[W] 330 335 340 345
[A] 10.41 10.47 10.52 10.58
[V] 40.15 40.41 40.66 40.92
[A] 9.91 9.97 10.02 10.07
[V] 33.29 33.62 33.94 34.25
[%] ≥ 18.4 ≥ 18.7 ≥ 19.0 ≥ 19.3
[W] 247.0 250.7 254.5 258.2
[A] 8.39 8.43 8.48 8.52
[V] 37.86 38.10 38.34 38.59
[A] 7.80 7.84 7.89 7.93
[V] 31.66 31.97 32.27 32.57
[V] 1000 (IEC) / 1000 (UL)II
[A DC] 20 C (IEC) / TYPE 2 (UL)
[lbs / ft2] 50 (2400 Pa) / 50 (2400 Pa)
− 40 °F up to + 185 °F
(− 40 °C up to + 85 °C)[lbs / ft2] 75 (3600 Pa) / 75 (3600 Pa)
3 See Installation Manual
Certified
UL 1703
(254141)
Hanwha Q CELLS America Inc.
400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.us
MECHANICAL SPECIFICATION
Format 68.5 × 40.6 × 1.57 in (including frame)
(1740 × 1030 × 40 mm)
Weight 47.4 lbs (21.5 kg)
Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass
with anti-reflection technology
Back Cover Composite film
Frame Black anodized aluminum
Cell 6 × 20 monocrystalline Q.ANTUM solar half cells
Junction Box 2.09-3.98 × 1.26-2.36 × 0.59-0.71 in (53-101 × 32-60 × 15-18 mm),
Protection class IP67, with bypass diodes
Cable 4 mm² Solar cable; (+) ≥ 43.3 in (1100 mm), (−) ≥ 43.3 in (1100 mm)
Connector Stäubli MC4; IP68
Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use
of this product.
Sp
e
c
i
f
i
c
a
t
i
o
n
s
s
u
b
j
e
c
t
t
o
t
e
c
h
n
i
c
a
l
c
h
a
n
g
e
s
©
Q
C
E
L
L
S
Q.
P
E
A
K
D
U
O
B
L
K
-
G
6
+
/
S
C
_
3
3
0
-
3
4
5
_
2
0
1
9
-
1
1
_
R
e
v
0
1
_
N
A
ELECTRICAL CHARACTERISTICS
POWER CLASS
MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)
Mi
n
i
m
u
m
Power at MPP1 PMPP
Short Circuit Current1 ISC
Open Circuit Voltage1 VOC
Current at MPP IMPP
Voltage at MPP VMPP
Efficiency1 Ș
MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2
Mi
n
i
m
u
m
Power at MPP PMPP
Short Circuit Current ISC
Open Circuit Voltage VOC
Current at MPP IMPP
Voltage at MPP VMPP
1 Measurement tolerances PMPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2 800 W/m², NMOT, spectrum AM 1.5
Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE
At least 98 % of nominal power during
first year. Thereafter max. 0.54 %
degradation per year. At least 93.1 %
of nominal power up to 10 years. At
least 85 % of nominal power up to
25 years.
All data within measurement toleranc-
es. Full warranties in accordance with
the warranty terms of the Q CELLS
sales organization of your respective
country.
Typical module performance under low irradiance conditions in
comparison to STC conditions (25 °C, 1000 W/m²)
TEMPERATURE COEFFICIENTS
Temperature Coefficient of ISC Temperature Coefficient of VOC
Temperature Coefficient of PMPP Normal Module Operating Temperature
PROPERTIES FOR SYSTEM DESIGN
Maximum System Voltage VSYS Protection Class
Maximum Series Fuse Rating Fire Rating based on ANSI / UL 1703
Max. Design Load, Push / Pull (UL)3 Permitted Module Temperature
on Continuous DutyMax. Test Load, Push / Pull (UL)3
QUALIFICATIONS AND CERTIFICATES
UL 1703, CE-compliant, IEC 61215:2016, IEC 61730:2016,
Application Class II, U.S. Patent No. 9,893,215 (solar cells)
200 400 600 800 1000
110
100
90
80
RE
L
A
T
I
V
E
E
F
F
I
C
I
E
N
C
Y
[
%
]
IRRADIANCE [W/m²]
RE
L
A
T
I
V
E
E
F
F
I
C
I
E
N
C
Y
CO
M
P
A
R
E
D
T
O
N
O
M
I
N
A
L
P
O
W
E
R
[
%
]
100
95
90
85
80
75
1552520010
YEARS
98
Q CELLS
Industry standard for tiered warranties*
Industry standard for linear warranties*
*Standard terms of guarantee for the 10 PV companies
with the highest production capacity in 2014 (as at: September 2014)
37.4" (950 mm)
68.5" (1740 mm)
4 × Fastening points (DETAIL A)
Frame
6.06"
(154 mm)
40.55" (1030 mm)
38.6" (981 mm)
1.57" (40 mm)
8 × Drainage opening
0.14" × 3.1" (3.6 mm × 8 mm)
6 × Grounding points ø 0.16" (4 mm)
Label
DETAIL A 0,472" (12 mm)
0.354" (9 mm)1.063" (27 mm)
15.6“ (395 mm)
7.09" (180 mm)
4 × Drainage opening
≥ 43.3" (11
00
m
m)
≥ 43.
3" (11
00
m
m)
HDFKSURGXFW7KHHQGXVHUGRFXPHQWDWLRQVKLSSHGZLWK=HS6RODU ¶VSURGXFWVFRQVWLWXWHVWKHVROHVSHFL¿FDWLRQVUHIHUUHGWRLQWKHSURGXFWZDUUDQW\7KHFXVWRPHULVVROHO\
UHVSRQVLEOHIRUYHULI\LQJWKHVXLWDELOLW\RI=HS6RODU¶VSURGXFWVIRUHDFKXVH6SHFL¿FDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH3DWHQWVDQG$SSV]VSDWVFRP
IRUFRPSRVLWLRQVKLQJOHURRIV
DQ\PDQXIDFWXUHUFHUWL¿HGDV³7\SH´RU³7\SH´
6SHFL¿FDWLRQV
HDFKSURGXFW7KHHQGXVHUGRFXPHQWDWLRQVKLSSHGZLWK=HS6RODU¶VSURGXFWVFRQVWLWXWHVWKHVROHVSHFL¿FDWLRQVUHIHUUHGWRLQWKHSURGXFWZDUUDQW\7KHFXVWRPHULVVROHO\
UHVSRQVLEOHIRUYHULI\LQJWKHVXLWDELOLW\RI=HS6RODU¶VSURGXFWVIRUHDFKXVH6SHFL¿FDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH3DWHQWVDQG$SSV]VSDWVFRP
1H[W/HYHO390RXQWLQJ7HFKQRORJ\
]HSVRODUFRP
3DUW1R
/LVWHGWR8/
&DSWXUHG:DVKHU/DJ
3DUW1R
)ODVKLQJ,QVHUW
3DUW1R
/LVWHGWR8/
$UUD\6NLUW
3DUW1RRU
/LVWHGWR8/
3DUW1RRU
/LVWHGWR8/
(QG&DS
3DUW1R
/RU
5RU
'&:LUH&OLS
3DUW1R
/LVWHGWR8/
*URXQG=HS9
3DUW1R
/LVWHGWR8/DQG8/
,QWHUORFN
3DUW1RRU
/LVWHGWR8/
/HYHOLQJ)RRW
3DUW1R
/LVWHGWR8/