Loading...
HomeMy WebLinkAboutDriveway and concreteSHEET 1 OF 2 (SURVEY SKETCH) ------------ SURVEY NOT COMPLETE WITHOUT ALL _SHEETS MAP OF BOUNDARY SURVEY PREPARED FOR SHYAN WOJTCZAK AND JEFF MARSHALL SANTANA AVENUE x (70- R/W) x x 20' ASPHALT Rawmy Aq —NW CORNER OF BLOCK 30 N90'00'00'E 500.42' -'o� N90*00,00"E eat.160! T FIP I" (NO 1)) L BEAR BASING LOT 24 00 B o LOCK 3 0 ..:,. PROPOSED TV. DRAIEWAY 22.0 22.0 / ,� // I 17901 0 STORY CBS I -5 PROPOSED 22.5 22.1 I e-�30.6— LOT 25 I BLOCK 30 LOT 22 BLOCK 30 VW-3 z DRALMEUD 07AAED i POOL 0% IX RE•22.2 im'i2 LOT 23 BLOCK 30 Lo 10' P.U. D.E. ko (NO N89*58'56'W 160,001 LOT 6 LOT 7 BLOCK 30 BLOCK 30 LOT 8 LOT 9 BLOCK 30 BLOCK 30 NOTES: ELEVATION NOTES: NORTH ARROW & ALL BEARINGS AND DISTANCES SHOWN ARE RECORD AND ALL ELEVATIONS SHOWN ARE BASED UPON NORTH AMERICAN GRAPHIC SCALE MEASURED UNLESS OTHERWISE SHOWN. VERTICAL DATUM OF 1988 (NAVD-88). 4 P.U.&D.E. PUBLIC UTILITY AND DRAINAGE EASEMENT. PROPOSED FINISHED FLOOR ELEVATION IS SUBJECT TO CHANGE BEARINGS ARE BASED UPON THE RECORD BEARING FOR THE PER HEALTH DEPARTMENT. SOUTHERLY RIGHT OF WAY LINE OF SANTANA AVENUE 1" = 30' PERMIT NUMBER AND CONTACT N/A FASTING ELEVATION- E"A'nON- \-2= DRAINAGE ARROW JOB 2ODS-305 REVISION - KNOW IT NOW, INC. PROFESSIONAL SURVEYING AND MAPPING 5220 US HIGHWAY 1, #104 VERO BEACH, FL 32967 PHONE - (888) 396-7770 WWW.KINSURVEYORS.COM • • FIELD DATE - 09/02/2020_ REVISION - REVISION - REVISION - REVISION - REVISION - REVISION - REVISION - REMSION - REVISION - FLORIDA BUSINESS CERTIFICATE OF AUTHORIZATION NUMBER LB 6912 ----------- ----, 1� -1 'EM, COMPONENTS AND CLADDING, AND CTRICAL, INGRESS/EGRESS, PROPERTY IE THE RESPONSIBILITY OF OTHERS. Y 1) CAPABLE OF SUPPORTING DEAD ;ALLY ADDRESSED HEREIN, INCLUDING AND NOT PROVIDED AND INSTALLED AT THE OWNER'S RISK. CARPORTS GE OR FAILURE DUE TO THE .4.2. D03/A1003M-15. REQUIREMENTS ARE THE iHERS ® 6" O.C. MAX. E IN SHOP BY A CERTIFIED WELDER. IENGTH. 4"x54" EXPANSION ANCHOR WITHIN 6" OF EACH POST/TRUSS ALONG SIDES AND EVERY OTHER END —WALL POST 2" MIN. BASE RAIL GRAD _ a o 2,500 PSI 4" CONCRETE SLAB WITH 10GA. W.W.F. OR FIBER MESH /CA UM SOIL BEARING CONTINUOUS WITH MINIMUM PACITY 500 PSF(TYP.) 12" OVERLAP SPLICE CONCRETE FOUNDATION/BASE RAIL ANCHOR DETAIL PLAN VIEW 2 5" DOOR FRAMING J" RECESS 4 OOR WIDTH ELEVATION VIEW DOOR FRAMING " RECESS .75"T 4" _DOOR WIDTH OPTIONAL ROLL -UP DOOR CONCRETE SPLASH -GUARD RECESS i 'z i i 10 In- i i 0 I i ROLL-4UP O DOOR T i CAM YERE CODE INFORMATION CODE VERSION FBC 2017 6th Edition, ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-150mph EXPOSURE B ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFF. +/— 0.18 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD 10PSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 11,200 SQ_ FT. Uw{wN UT: MTB DATE: 8/9/20 Loc0ft 7901 Santana Ave., Ft. Pierce SIZE 40'L X 30'W X 1O'H tn�A$ I.,. .70MERPEWTTING COMTRACTOR pYf Li > 8/ 1 1 /20 z Matthew T. Baldwin P.E. Florida License #64608 Fn Sheet: CA-1 OF 4 F--------------- 1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYS BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, EL SET -BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS A 2, THIS STRUCTURE IS DESIGNED AS A NON -HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGOI LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIF DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIS' BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BI ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAM APPLICATION OF ADDITIONAL LOADS. 3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C10 4.ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM A 5.PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, AND/OR OTHER LOCAL CODE RESPONSIBILITY OF THE OWNER. 6. ROOF AND WALL SHEATHING SECURED WITH #12-141" SELF -DRILLING SCREWS WITH SEAL WA 7. FIELD FRAMING CONNECTIONS SECURED WITH #12-14x3/4" SELF -DRILLING SCREWS. 8. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. NO WELDING ONSITE. ALL WELDING DOI 9. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,50OL8 TENSILE ST 10. 12 OR 14GA. FRAMING IS 2.5"x2.5" TUBE STEEL. NIPPLES ARE 2.25"x2.25" TUBE STEEL. ��'T SUB -GRADE SOILS: -TO BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION R318 AND 1816 OF THE 2017 FLORIDA BUILDING CODE, 6TH EDITION CONCRETE: -MINIMUM 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE DESIGNED TO SLOPE AWAY FROM THE STRUCTURE REINFORCING STEEL (REBAR) REQUIREMENTS- -MINIMUM GRADE 40 STEEL -REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED: -THE REBAR IS BENT COLD -THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED 6-BAR DIAMETERS: AND -REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL CELL. THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1" HORIZONTALLY TO 6" VERTICALLY. -COVER: -2" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH SOIL OR WEATHER, AND 11" ELSEWHERE. REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF I" FOR FINE GROUT, AND J" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL. REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER, AND 1i" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER. GALVANIZATION: -METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153, CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED. IN. 2,500 PSI 4" CONCRETE SLAB WITH 10GA. W.W.F. (OR FIBER MESH) AND 12"x12" REINFORCED FOOTER PERIMETER rl2"xl2" REINFORCED FOOTER ------------------------------------ m