Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ftelerl Project Name: CARVILLE O'CARROLL ADDITION APR Builder Name: Street: 2414 53rd STREET 2 Iftlermit Office: City, State, Zip: FT. PIERC , FL, f'er;;n Permit Number: Owner: �ko 4uet� Ca untRTedsdiction: Design Location: FL, Fort Pierce &unty: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types (746.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insui, Exterior R=5.4 634.67 ft2 b. Concrete Block - Ext Insul, Adjacent R=4.1 112.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 1(1) d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (724.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 724.00 ft2 6. Conditioned floor area above grade (ft2) 724 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(75.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: ADDITION 6 144 a. U-Factor: Dbl, U=0.65 40.00 ft2 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=0.65 35.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 35.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.277 14. Hot water systems - Replacement equipment a. Electric Cap: 50 gallonsEF: 8. Floor Types (724.0 sqft.) Insulation Area 0.950 a. Slab -On -Grade Edge Insulation R=0.0 724.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF, Pstat Total Proposed Modified Loads: 20.31 Glass/Floor Area: 0.104 PASS Total Baseline Loads: 23.09 I hereby certify that the plans and specifications covered by Review of the plans and �Zfr1E S7, this calculation are in compliance with the Florida Energy specifications covered by this b� = �0V, Code. calculation indicates compliance _ �@Twith the Florida Energy Code.Oi~ PREPAR D BY:Q DATE: .. Before construction is completed this building will be inspected for r� ' " o compliance with Section 553.908 Thereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'OD WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. •- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). t :• �w.'4. � 7 C: 4/11/2019 11:38 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R465-2017 INPU'--.�JMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: CARVILLE O'CARROLL ADD Bedrooms: 1 User Conditioned Area: 724 Total Stories: 1 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Single-family Addition Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Street Address 2414 53rd STREET St. Lucie FT. PIERC , FL, CLIMATE / Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 724 5792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 ADDITION 724 5792 No 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio ADDITION 125 ft 0 724 ftZ ---- 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 784 ftZ 0 ftZ Light 0.6 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RIBS IRCC 1 Full attic Vented 150 724 ftZ N N CEILING • # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) ADDITION 30 Blown 724 ftZ 0.11 Wood 4/11/2019 11:38 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R465-2017 INPI"��-JMMARY CHECKLIST RFPnRT'_ WALLS ()Ent Adjacent Space Cavity Width Height Sheathing Framing Solar TO IMMI Type1 Belo w E 2 S 3 N 4 W Exterior Concrete Block - Ext Insu#DDITION 5.4 38 8 304.0 ft2 0 Exterior Concrete Block - Ext InsL ADDITION 5.4 23 4 8 186.7 ft2 0 Exterior Concrete Block - Ext InsLADDITION 5.4 18 8 144.0 ft2 0 Garage Concrete Block - Ext InsUADDITION 4.0999 14 8 112.0 ft2 0 0 0.5 0 0.5 0 0.5 0 0.6 0 0 0 0 WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 2 3 E 1 Metal Low-E Double Yes 0.65 0.3 N 40.0 ft2 2 ft 0 in 1 ft 4 in E 1 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in N 3 Metal Low-E Double Yes 0.65 0.25 N 20.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Drapes/blinds Drapes/blinds None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 378 ft2 378 ft2 64 ft 8 ft 4.1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 675.7 37.1 69.77 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/Supplemen None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Supplemental for None SEER: 16 35 kBtu/hr 1050 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None ADDITION 0.95 50 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM ' FSEC Collector Cert # Company Name System Model # Collector Model # Area Storage Volume FIEF None None ft2 4/11/2019 11:38 AM EnergyGauge D USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPU` jMMARY CHECKLIST REPORT' DUCTS V -- Supply ---- --- Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 144 ftz Attic 50 ftZ Default Leakage ADDITION (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Jan Venting Feb Feb Mar M ki Apr I Ma I Jun rl Jun Jul Jul ri Au rl X Se OctOct Nov Nov Dec Dec Jan Feb Mar Ae pr May Jul Auun g Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80. 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 6& 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftZ Oft 0.3 ADDITION Name: Rating Compant: 4/11/2019 11:38 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4 i 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CR1'rriRIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: CARVILLE O'CARROLL ADDITION Builder Name: Street: 2414 53rd STREET Permit Office: City, State, Zip: FT. PIERC , FL, Permit Number: Y Owner: Jurisdiction: U w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit Y PP 9 /soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall, thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinklgr aQy&Lp1aW and walls or ceilings a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/11/2019 11:38 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 88 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 1 13. Cooling system: Capacity 35.0 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 724 d) Room unit/PTAC EER e) Other 16.0 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.277 c) Area 7c. 75.0 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 5.4 14. Heating system: Capacity 27.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE 0 Other 15. Water heating system a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other 1061. 10132. 4.1 16. HVAC credits claimed (Performance Method) a) Ceiling fans Yes 11a. 30.0 b) Cross ventilation No 11 b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit 0 Programmable thermostat Yes "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signatu Date: Address of New Home: 2414 53rd STREET City/FL Zip: FT. PIERC, FL 4/11/2019 11:38:18 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1