FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: SINGLE FAMILY HOME
Builder Name:
Street: 6604 DELEON AVE
Permit Office: FORT PIERCE CITY
City, State, Zip: FORT PIERCE, FL, 34951
Permit Number:
Owner: 21ST STREET, LLC
Jurisdiction: 661100
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1594.4 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1516.70 ft2
b. Concrete Block - Int Insul, Adjacent
R=11.0 77.78 ft2
3. Number of units, if multiple family 1
c. NIA
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (1521.0 sqft.)
Insulation , Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1521.00 ft2
6. Conditioned floor area above grade (ft2) 1521
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c.
R= ft2
11. Ducts
R ft2
7. Windows(198.1 sqft.) Description Area
a. Sup: Foyer and Hall, Ret: Foyer and Hall, AH: Foy4.2 117.5
a. U-Factor: Sgl, U=1.07 198.06 ft2
SHGC: SHGC=0.35
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
34.0 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
32.8 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 4.434 ft.
Area Weighted Average SHGC: 0.350
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1521.0 sqft.) Insulation Area
EF: 0.975
a. Slab -On -Grade Edge Insulation R=0.0 1521.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 49.36
Glass/Floor Area: 0.130
PASS
Total Baseline Loads: 51.23
I hereby certify that the plans and specifications cover q WW I I I III/////
Review of the plans and
O4�BE S�,ql�
this calculation are in compliance with the Florida\ � T �
/Vecifications covered by this
�y �� _ OA
= ix:
Code. ����
sit -III: j'•,rgy
compliance
C6 iip
�� •
Code.
W��is
!� rrrn'•�" :,.•„ O
PREPARED BY: EES Inr : \\DENS
completed
r
DATE: 9-1&1B1202 -
43414
this buigng will be inspected for
_�
c� y
.
*
c&n liaae with Section 553.908
FI€ir statutes.
* '
I hereby certify that this building, as esigne��i,'n com
OF�
with the Florida Energy Co � � ;TATE
, � \
D WE
OWNER/AGENT: �i�'�OR10p.
�.> �I� ING OFFICIAL:
eeeeeee
S
DATE: `�-IS-ZO20 �i,
\^:
- Compliance requires certification by the air handleVii{iNWa'\\\ufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH60 (R402.4.1.2).
- Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house.
9/18/2020 8:50 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: SINGLE FAMILY HOME
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1521
Lot #
Owner Name: 21 ST STREET, LLC
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name:
Rotate Angle: 90
Street:
5504 DELEON AVE
Permit Office: FORT PIERCE CITY
Cross Ventilation:
County:
St. Lucie
Jurisdiction: 661100
Whole House Fan:
City, State, Zip:
FORT PIERCE,
Family Type: Single-family
FL , 34951
New/Existing: New (From Plans)
Comment:
CLIMATE
V
Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Block1
1521 14190.9
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 Family Room
383 3573.4 No 1
0
1 Yes
Yes
Yes
2 Owner Suite
194 1810 No 2
1
1 Yes
Yes
Yes
3 Owner Suite Bath C
144 1343.5 No 0
0
1 Yes
Yes
Yes
4 Kitchen
202 1884.7 Yes 0
0
1 Yes
Yes
Yes
5 Bedroom 2
128 1194.2 No 1
1
1 Yes
Yes
Yes
6 Foyer and Hall
230 2145.9 No 0
0
1 Yes
Yes
Yes
7 Bedroom 3
150 1399.5 No 1
1
1 Yes
Yes
Yes
8 Laundry Room
38 354.5 No 0
0
1 Yes
Yes
Yes
9 Bathroom 2
52 485.2 No 0
0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
Family Room 78.33 ft 0
383 ft2
----
0 0
1
2 Slab -On -Grade Edge Insulatio
Owner Suite 55.42 ft 0
194 ftZ
_---
0 0
1
3 Slab -On -Grade Edge Insulatio
Owner Suite Bath48.67 ft 0
144 ftZ
----
0 0
1
4SIab-On-Grade Edge Insulatio
Kitchen 62.75 ft 0
202 ftZ
----
0 0
1
5 Slab -On -Grade Edge Insulatio
Bedroom 2 46.33 ft 0
128 ft2
----
0 0
1
6 Slab -On -Grade Edge Insulatio
Foyer and Hall 88.67 ft 0
230 ft2
----
0 0
1
7 Slab -On -Grade Edge Insulatio
Bedroom 3 54.33 ft 0
150 ft2
----
0 0
1
9/18/2020 8:50 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio Laundry Room 37.65 ft 0
38 ft2
----
0
0
1
9 Slab -On -Grade Edge Insulatio Bathroom 2 30.58 ft 0
52 ft2
----
0
0
1
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Gable or shed Barrel tile 1603 ft2
252 ft2 Medium
N
0.75
No 0.9
No 0
18.4
ATTIC
RBS
IRCC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
1
Partial cathedral cei Vented
300
1521 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) Family Room
30
Blown
383 ft2
0.08
Wood
2
Under Attic (Vented) Owner Suite
30
Blown
194 ft2
0.08
Wood
3
Under Attic (Vented) Owner Suite Bath 30
Blown
144 ft2
0.08
Wood
4
Under Attic (Vented) Kitchen
30
Blown
202 ft2
0.08
Wood
5
Under Attic (Vented) Foyer and Hall
30
Blown
230 ft2
0.08
Wood
6
Under Attic (Vented) Bedroom 3
30
Blown
150 ft2
0.08
Wood
7
Under Attic (Vented) Bedroom 2
30
Blown
128 ft2
0.08
Wood
8
Under Attic (Vented) Laundry Room
30
Blown
38 ft2
0.08
Wood
9
Under Attic (Vented) Bathroom 2
30
Blown
52 ft2
0.08
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
rnt
To Wall -Type Space R-Value
Et In Ft In
Area
R=Value-Fraction-Absor--Grad"O
1
E=>S
Exterior Concrete Block - Int Ins&mily Room
4.1 20
8 9
4
192.9 ft2
0
0.5
0
2
S=>W
Exterior Concrete Block - Int Insfibmily Room
4.1 19
10 9
4
185.1 ft2
0
0.5
0
3
S=>W
Exterior Concrete Block - Int Insul Kitchen
4.1 9
4 9
4
87.1 ft2
0
0.5
0
4
S=>W
Exterior Concrete Block - Int InsuBedroom 3
4.1 11
4 9
4
105.8 ft2
0
0.5
0
5
W=>N
Exterior Concrete Block - Int InsFiibyer and Hal
4.1 5
0 9
4
46.7 ft2
0
0.5
0
6
W=>N
Exterior Concrete Block - Int InsuBedroom 2
4.1 11
0 9
4
102.7 ft2
0
0.5
0
7
N=>E
Exterior Concrete Block - Int InsuBedroom 2
4.1 13
11 9
4
129.9 ft2
0
0.25
0
8
N=>E
Exterior Concrete Block - Int Insilaundry Roo
4.1 6
3 9
4
58.3 ft2
0
0.5
0
9
N=>E
Exterior Concrete Block - Int Ins®wner Suite
4.1 14
7 9
4
136.1 ft2
0
0.5
0
10
N=>E
Exterior Concrete Block - Int InsL(Dwner Suite
4.1 15
6 9
4
144.7 ft2
0
0.5
0
11
E=>S
Exterior Concrete Block - Int InsL(Dwner Suite
4.1 14
4 9
4
133.8 ft2
0
0.5
0
12
N=>E
Exterior Concrete Block - Int InsL6athroom 2
4.1 5
5 9
4
50.6 ft2
0
0.5
0
_13
N=>E
Exterior Concrete Block- Int Ins6hamily Room
4.1 8
0 9
4
74.7 ft2
0
0.5
0
14
S=>W
Exterior Concrete Block - Int InsuBedroom 2
4.1 7
4 9
4
68.4 ft2
0
0.5
0
15
W=>N
Garage Concrete Block - Int InsuBedroom 3
11 8
4 9
4
77.8 ft2
0
0.5
0
9/18/2020 8:50 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DOORS
#
Ornt
Door Type Space
Storms
U-Value Width
Ft In
Height
Ft In
Area
1
W=>N
Wood Foyer and Hal None
.46 3
8
24 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
V #
Wall
Ornt ID Frame
Panes NFRC
U-Factor SHGC Imp
Overhang
Area Depth Separation
Int Shade
Screening
1
2
3
4
5
6
7
8
9
E=>S 1 Metal
S=>W 2 Metal
S=>W 4 Metal
W=>N 6 Metal
N=>E 8 Metal
N=>E 12 Metal
N=>E 9 Metal
N=>E 10 Metal
N=>E 13 Metal
Single (Tinted) Yes
Single (Tinted) Yes
Single (Tinted) Yes
Single (Tinted) Yes
Single (Tinted) Yes
Single (Tinted) Yes
Single (Tinted) Yes
Single (Tinted) Yes
Single (Tinted) Yes
1.07 0.35 N
1.07 0.35 N
1.07 0.35 N
1.07 0.35 N
1.07 0.35 N
1.07 0.35 N
1.07 0.35 N
1.07 0.35 N
1.07 0.35 N
49.3 ft2 1 ft 6 in 1 ft 0 in
16.4 ft2 1 ft 6 in 1 ft 0 in
16.4 ft2 1 ft 6 in 1 ft 0 in
19.5 ft2 1 ft 6 in 1 ft 0 in
12.8 ft' 1 ft 6 in 1 ft 0 in
12.8 ft' 1 ft 6 in 1 ft 0 in
6.2 ft2 1 ft 6 in 1 ft 0 in
32.0 ft2 8 ft 0 in 1 ft 0 in
32.4 ft2 13 ft 0 in 1 ft 0 in
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
None
None
None
None
None
None
None
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1
378 ft2
378 ft2
78 ft
9.33 ft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000296
1182.6 64.92 122.1 .1092
5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/ None
COP:1
32.75 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 15
34 kBtu/hr 1200 cfm
0.83 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType Location
EF Cap
Use SetPnt
Conservation
1
Electric
None Garage
0.975 50 gal
40 gal 120 deg
None
9/18/2020 8:50 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of.5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
---- Supply ----
V
---- Return ----
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location Area Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Foyer and Hal 4.2 117.5 ft Foyer and Hal39.9 ft2 Prop. Leak Free Foyer and
--- cfm
45.6 cfm 0.03
0.65
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan Feb Mar
Apr
Ma X Jun Jul
X Au
X Se
Oct
Nov
Dec
Jan Feb Mar
�X�
Jun Jul
rl
Aug
I
Sep
I
Nov
Venting X
Apr
May Jun Jul
Aug
Sep
Oct lxj
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2
3 4 5 6
7
8
9 10
11
12
Cooling (WD) AM 78
78
78 78 78 78
78
78
80 80
80
80
PM 80
80
78 78 78 78
78
78
78 78
78
78
Cooling (WEH) AM 78
78
78 78 78 78
78
78
78 78
78
78
PM 78
78
78 78 78 78
78
78
78 78
78
78
Heating (WD) AM 66
66
66 66 66 68
68
68
68 68
68
68
PM 68
68
68 68 68 68
68
68
68 68
66
66
Heating (WEH) AM 66
66
66 66 66 68
68
68
68 68
68
68
PM 68
68
68 68 68 68
68
68
68 68
66
66
MECHANICAL VENTILATION
Type Supply CFM
Exhaust CFM Fan Watts HRV Heating System
Run Time Cooling System
Runtime Vent 15
0 0 0 1 - Electric Strip Heat
% 1 - Central Unit
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
Family Room
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
Owner Suite
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
Owner Suite Bath
C
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
Kitchen
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
Bedroom 2
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
Foyer and Hall
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
Bedroom 3
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
Laundry Room
Default(8 Ibs/s .ft.
0 ft2
Oft
0.3
Bathroom 2
9/18/2020 8:50 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
4.2
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
4.2
c) AHU location Foyer and Hall
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
34.0
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1521
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.070
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.350
14. Heating system: Capacity
32.8
c) Area
7c.
198.1
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.98
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
2. Masonry (Insulation R-value)
10132.
11.0
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: 5504 DELEON AVE City/FL Zip: FORT PIERCE, FL 34951
9/18/2020 8:51:28 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: SINGLE FAMILY HOME Builder Name:
Street: 5504 DELEON AVE Permit Office: FORT PIERCE CITY
City, State, Zip: FORT PIERCE, FL, 34951 Permit Number:
Y
U
Owner: 21STSTREET, LLC Jurisdiction: 661100
=
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind Wing and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
9/18/2020 8:51 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Duct Leakage Test Report
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: 661100 Permit #:
. Cs
�
-Job lrif6llon
Builder: Community: Lot: NA
Address: 5504 DELEON AVE
City: FORT PIERCE State: FL Zip: 34951
Ductea Lkage Test Resurt s . 0 Prescriptive titthod ,, < Performance/ERI Method
s
System 1
cfm25
System 2
cfm25
System 3
cfm25
Sum of any
cfm25
Total of all
cfm25
. 1521 = Qn
Total of all Total Conditioned
systems Square Footage
-
Q Prescriptive,Method'."cfm25'(Total).
'To qualify as', "substantially;: leak free" Qn Total; must' be less than or
equal=to 0:04ifair. handler unit is.installed ff air`handler uniti, is not, .
`' installed, Qn,Total.must be less.th`an or equt'6 al b,,.03. This testing
method meets the requirements in accordance witl Section R403.3.3.
Is„the aint andler- unit yinstalledlduring testing? ' ` YES (�a°�j 0 NO ('c4
6. Performance/ERI .Method cfm25 (out or Totai)
$- To qualify using this method, Qn must not be greater than the
,. proposed;duct leakage'Qn'specifed.on Form R405-2017 or,R406-2017
Leakage Type selected on<Foal"
m,; `'y Qn specled on Form R405-2017
1,405-201,.7 (Energy'Calc)-or R406-2017 (EnelrgyCalcJ or R406-201T
..4 . 'J G t i t_ ;�, i t
PASS FAIL Proposed Leak Free 0.03
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section
553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes.
Testing' Company s
Company Name: Phone:
I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the
selected compliance path as stated above, either the Prescriptive Method or Performance Method.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #:
Issuing Authority:
9/18/2020 8:51:57 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2008-0443
Building Permit #
Planning & Development Services Department
Building & Regulations Division
Product Review Affidavit
Owners Name 434 21 st Street LLC
Applicant:
Pedro Quijada
Product
Opening Design
Pressures
Product Rated
Design Pressure
Manufacturer
Model Number
Product Approval
Number
Glass
Type
Method of Attachment
Windows
55.0
65.0
CGI
SH-4100A
FL23358.2
Lami
Flange Frame
Mullions
90.0
90.0
CGI
Series Clipped
18-0129.08
Fixed Glass
55.0
65.0
CGI
PW-4120A
FL26095.2
Lami
Flange Frame
Block Glass
Skylights
Sliding Glass Doors
55.0
65.0
CGI
SGD-4130A
FL29078.2
Lami
Flange Frame
Swing Type Doors
50.0
50.0
Therma-Tru
Smooth Star
FL20468.6
Lami
French Doors
Garage Doors
Hurricane Protection
Roof Ventilation
N/A
N/A
O'Hagin
Cloaked Vent
19-0109.02
REVIEWEp FOR
Roofing Material
N/A
N/A
GAF
Asphalt Shin
a
FL10124-R27
®DE Co 096)WE
T 4
Revised 07/22/2014
— - — -g r n
BOCC
I have reviewed the above components or cladding and I have approved their use in this structure. These products Drovide adequate resistance to the
wind loads and forces specified by current code provisions. 1EOFFCOR Digitally signed by Scott
y`. Blakeslee Disher
Scott Disher P. DN:cn=Scots Blakeslee
Name: Signature: Disher,
9/17/20 osg,�
Architect AR 11586 `aw
REOPa email=sdisher@archstudiofl.c
Design Prof: Cert. No. Date: w�` „ gW om, c=us
Date: 2020.09.1811:31:43
-04'00'
E Copy
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance FILE COPY
Project Name: Single Family Model Residence
Project Address:
5504 Deleon Avenue
Permit #: Occupancy Type: R-3 Construction Type: IV
INSTRUCTIONS FOR USE:
This certification must be completed, signed, and sealed by the design professional of record.
Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition REVIEWED FOR
o Any accessory structure requiring a g D sOM PLQA CE
o Any non-residential structure. �.�.` ����� ��
* Note: Form not required for interior renovations rovided a no a r rr r ra elements are affected and
certain minor building permits at the discretion of the local bullAw.'Contact the # above for questions.
.DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Sixth Edition with 2017 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: ft
S. Mean Roof Height 13.416 ft Roof Pitch: 4 :12 Parapet. N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
N/A p, o — 2. N/A one N/A =41M/-45.01�5.03/42.63 Garage: 35.03/ 42.63
7. Design Loads: Floor: 100 TTL PSF Roof/Dead:15 TC PSF Roof/Live: 30 TC Balcony: N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: 40 PS F:.nCe N/A PSF Railings: 200 CL PSF
0 Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
1a Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Scott Disher
Print Name Cert # & Co. Cert Auth.
AR 11586
Signature, Date, and Seal Architectural Studio, Inc., Palm Beach Gardens, FL
Company Name & Address
Revised 12/07/2018