HomeMy WebLinkAboutEnergy Code•...v vcu D(X%' Q LY43 SEP 2 3 2020 FORM R405-2017 Permitting Department St, Lucie County FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SINGLE FAMILY HOME Builder Name: Street: 6604 DELEON AVE Permit Office: FORT PIERCE CITY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Owner: 21ST STREET, LLC Jurisdiction: 661100 Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1594.4 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1516.70 ft2 b. Concrete Block - Int Insul, Adjacent R=11.0 77.78 ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1521.0 sqft.) Insulation , Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1521.00 ft2 6. Conditioned floor area above grade (ft2) 1521 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. R= ft2 11. Ducts R ft2 7. Windows(198.1 sqft.) Description Area a. Sup: Foyer and Hall, Ret: Foyer and Hall, AH: Foy4.2 117.5 a. U-Factor: Sgl, U=1.07 198.06 ft2 SHGC: SHGC=0.35 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 34.0 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 32.8 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 4.434 ft. Area Weighted Average SHGC: 0.350 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1521.0 sqft.) Insulation Area EF: 0.975 a. Slab -On -Grade Edge Insulation R=0.0 1521.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 49.36 Glass/Floor Area: 0.130 PASS Total Baseline Loads: 51.23 I hereby certify that the plans and specifications cover q WW I I I III///// Review of the plans and O4�BE S�,ql� this calculation are in compliance with the Florida\ � T � /Vecifications covered by this �y �� _ OA = ix: Code. ���� sit -III: j'•,rgy compliance C6 iip �� • Code. W��is !� rrrn'•�" :,.•„ O PREPARED BY: EES Inr : \\DENS completed r DATE: 9-1&1B1202 - 43414 this buigng will be inspected for _� c� y . * c&n liaae with Section 553.908 FI€ir statutes. * ' I hereby certify that this building, as esigne��i,'n com OF� with the Florida Energy Co � � ;TATE , � \ D WE OWNER/AGENT: �i�'�OR10p. �.> �I� ING OFFICIAL: eeeeeee S DATE: `�-IS-ZO20 �i, \^: - Compliance requires certification by the air handleVii{iNWa'\\\ufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH60 (R402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house. 9/18/2020 8:50 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: SINGLE FAMILY HOME Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1521 Lot # Owner Name: 21 ST STREET, LLC Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: Rotate Angle: 90 Street: 5504 DELEON AVE Permit Office: FORT PIERCE CITY Cross Ventilation: County: St. Lucie Jurisdiction: 661100 Whole House Fan: City, State, Zip: FORT PIERCE, Family Type: Single-family FL , 34951 New/Existing: New (From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 1521 14190.9 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Family Room 383 3573.4 No 1 0 1 Yes Yes Yes 2 Owner Suite 194 1810 No 2 1 1 Yes Yes Yes 3 Owner Suite Bath C 144 1343.5 No 0 0 1 Yes Yes Yes 4 Kitchen 202 1884.7 Yes 0 0 1 Yes Yes Yes 5 Bedroom 2 128 1194.2 No 1 1 1 Yes Yes Yes 6 Foyer and Hall 230 2145.9 No 0 0 1 Yes Yes Yes 7 Bedroom 3 150 1399.5 No 1 1 1 Yes Yes Yes 8 Laundry Room 38 354.5 No 0 0 1 Yes Yes Yes 9 Bathroom 2 52 485.2 No 0 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Family Room 78.33 ft 0 383 ft2 ---- 0 0 1 2 Slab -On -Grade Edge Insulatio Owner Suite 55.42 ft 0 194 ftZ _--- 0 0 1 3 Slab -On -Grade Edge Insulatio Owner Suite Bath48.67 ft 0 144 ftZ ---- 0 0 1 4SIab-On-Grade Edge Insulatio Kitchen 62.75 ft 0 202 ftZ ---- 0 0 1 5 Slab -On -Grade Edge Insulatio Bedroom 2 46.33 ft 0 128 ft2 ---- 0 0 1 6 Slab -On -Grade Edge Insulatio Foyer and Hall 88.67 ft 0 230 ft2 ---- 0 0 1 7 Slab -On -Grade Edge Insulatio Bedroom 3 54.33 ft 0 150 ft2 ---- 0 0 1 9/18/2020 8:50 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio Laundry Room 37.65 ft 0 38 ft2 ---- 0 0 1 9 Slab -On -Grade Edge Insulatio Bathroom 2 30.58 ft 0 52 ft2 ---- 0 0 1 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or shed Barrel tile 1603 ft2 252 ft2 Medium N 0.75 No 0.9 No 0 18.4 ATTIC RBS IRCC V # Type Ventilation Vent Ratio (1 in) Area 1 Partial cathedral cei Vented 300 1521 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Family Room 30 Blown 383 ft2 0.08 Wood 2 Under Attic (Vented) Owner Suite 30 Blown 194 ft2 0.08 Wood 3 Under Attic (Vented) Owner Suite Bath 30 Blown 144 ft2 0.08 Wood 4 Under Attic (Vented) Kitchen 30 Blown 202 ft2 0.08 Wood 5 Under Attic (Vented) Foyer and Hall 30 Blown 230 ft2 0.08 Wood 6 Under Attic (Vented) Bedroom 3 30 Blown 150 ft2 0.08 Wood 7 Under Attic (Vented) Bedroom 2 30 Blown 128 ft2 0.08 Wood 8 Under Attic (Vented) Laundry Room 30 Blown 38 ft2 0.08 Wood 9 Under Attic (Vented) Bathroom 2 30 Blown 52 ft2 0.08 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below rnt To Wall -Type Space R-Value Et In Ft In Area R=Value-Fraction-Absor--Grad"O 1 E=>S Exterior Concrete Block - Int Ins&mily Room 4.1 20 8 9 4 192.9 ft2 0 0.5 0 2 S=>W Exterior Concrete Block - Int Insfibmily Room 4.1 19 10 9 4 185.1 ft2 0 0.5 0 3 S=>W Exterior Concrete Block - Int Insul Kitchen 4.1 9 4 9 4 87.1 ft2 0 0.5 0 4 S=>W Exterior Concrete Block - Int InsuBedroom 3 4.1 11 4 9 4 105.8 ft2 0 0.5 0 5 W=>N Exterior Concrete Block - Int InsFiibyer and Hal 4.1 5 0 9 4 46.7 ft2 0 0.5 0 6 W=>N Exterior Concrete Block - Int InsuBedroom 2 4.1 11 0 9 4 102.7 ft2 0 0.5 0 7 N=>E Exterior Concrete Block - Int InsuBedroom 2 4.1 13 11 9 4 129.9 ft2 0 0.25 0 8 N=>E Exterior Concrete Block - Int Insilaundry Roo 4.1 6 3 9 4 58.3 ft2 0 0.5 0 9 N=>E Exterior Concrete Block - Int Ins®wner Suite 4.1 14 7 9 4 136.1 ft2 0 0.5 0 10 N=>E Exterior Concrete Block - Int InsL(Dwner Suite 4.1 15 6 9 4 144.7 ft2 0 0.5 0 11 E=>S Exterior Concrete Block - Int InsL(Dwner Suite 4.1 14 4 9 4 133.8 ft2 0 0.5 0 12 N=>E Exterior Concrete Block - Int InsL6athroom 2 4.1 5 5 9 4 50.6 ft2 0 0.5 0 _13 N=>E Exterior Concrete Block- Int Ins6hamily Room 4.1 8 0 9 4 74.7 ft2 0 0.5 0 14 S=>W Exterior Concrete Block - Int InsuBedroom 2 4.1 7 4 9 4 68.4 ft2 0 0.5 0 15 W=>N Garage Concrete Block - Int InsuBedroom 3 11 8 4 9 4 77.8 ft2 0 0.5 0 9/18/2020 8:50 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 W=>N Wood Foyer and Hal None .46 3 8 24 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. V # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 6 7 8 9 E=>S 1 Metal S=>W 2 Metal S=>W 4 Metal W=>N 6 Metal N=>E 8 Metal N=>E 12 Metal N=>E 9 Metal N=>E 10 Metal N=>E 13 Metal Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes 1.07 0.35 N 1.07 0.35 N 1.07 0.35 N 1.07 0.35 N 1.07 0.35 N 1.07 0.35 N 1.07 0.35 N 1.07 0.35 N 1.07 0.35 N 49.3 ft2 1 ft 6 in 1 ft 0 in 16.4 ft2 1 ft 6 in 1 ft 0 in 16.4 ft2 1 ft 6 in 1 ft 0 in 19.5 ft2 1 ft 6 in 1 ft 0 in 12.8 ft' 1 ft 6 in 1 ft 0 in 12.8 ft' 1 ft 6 in 1 ft 0 in 6.2 ft2 1 ft 6 in 1 ft 0 in 32.0 ft2 8 ft 0 in 1 ft 0 in 32.4 ft2 13 ft 0 in 1 ft 0 in Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 378 ft2 378 ft2 78 ft 9.33 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000296 1182.6 64.92 122.1 .1092 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 32.75 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 34 kBtu/hr 1200 cfm 0.83 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.975 50 gal 40 gal 120 deg None 9/18/2020 8:50 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of.5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply ---- V ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Foyer and Hal 4.2 117.5 ft Foyer and Hal39.9 ft2 Prop. Leak Free Foyer and --- cfm 45.6 cfm 0.03 0.65 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb Mar Apr Ma X Jun Jul X Au X Se Oct Nov Dec Jan Feb Mar �X� Jun Jul rl Aug I Sep I Nov Venting X Apr May Jun Jul Aug Sep Oct lxj Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System Runtime Vent 15 0 0 0 1 - Electric Strip Heat % 1 - Central Unit MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 Family Room Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 Owner Suite Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 Owner Suite Bath C Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 Kitchen Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 Foyer and Hall Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 Laundry Room Default(8 Ibs/s .ft. 0 ft2 Oft 0.3 Bathroom 2 9/18/2020 8:50 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 4.2 2. Single-family or multiple -family 2. Single-family b) Return ducts R 4.2 c) AHU location Foyer and Hall 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.0 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1521 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.070 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.350 14. Heating system: Capacity 32.8 c) Area 7c. 198.1 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 10132. 11.0 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 5504 DELEON AVE City/FL Zip: FORT PIERCE, FL 34951 9/18/2020 8:51:28 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: SINGLE FAMILY HOME Builder Name: Street: 5504 DELEON AVE Permit Office: FORT PIERCE CITY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Y U Owner: 21STSTREET, LLC Jurisdiction: 661100 = Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Wing and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 9/18/2020 8:51 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Duct Leakage Test Report Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: 661100 Permit #: . Cs � -Job lrif6llon Builder: Community: Lot: NA Address: 5504 DELEON AVE City: FORT PIERCE State: FL Zip: 34951 Ductea Lkage Test Resurt s . 0 Prescriptive titthod ,, < Performance/ERI Method s System 1 cfm25 System 2 cfm25 System 3 cfm25 Sum of any cfm25 Total of all cfm25 . 1521 = Qn Total of all Total Conditioned systems Square Footage - Q Prescriptive,Method'."cfm25'(Total). 'To qualify as', "substantially;: leak free" Qn Total; must' be less than or equal=to 0:04ifair. handler unit is.installed ff air`handler uniti, is not, . `' installed, Qn,Total.must be less.th`an or equt'6 al b,,.03. This testing method meets the requirements in accordance witl Section R403.3.3. Is„the aint andler- unit yinstalledlduring testing? ' ` YES (�a°�j 0 NO ('c4 6. Performance/ERI .Method cfm25 (out or Totai) $- To qualify using this method, Qn must not be greater than the ,. proposed;duct leakage'Qn'specifed.on Form R405-2017 or,R406-2017 Leakage Type selected on<Foal" m,; `'y Qn specled on Form R405-2017 1,405-201,.7 (Energy'Calc)-or R406-2017 (EnelrgyCalcJ or R406-201T ..4 . 'J G t i t_ ;�, i t PASS FAIL Proposed Leak Free 0.03 Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes. Testing' Company s Company Name: Phone: I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above, either the Prescriptive Method or Performance Method. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 9/18/2020 8:51:57 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2008-0443 Building Permit # Planning & Development Services Department Building & Regulations Division Product Review Affidavit Owners Name 434 21 st Street LLC Applicant: Pedro Quijada Product Opening Design Pressures Product Rated Design Pressure Manufacturer Model Number Product Approval Number Glass Type Method of Attachment Windows 55.0 65.0 CGI SH-4100A FL23358.2 Lami Flange Frame Mullions 90.0 90.0 CGI Series Clipped 18-0129.08 Fixed Glass 55.0 65.0 CGI PW-4120A FL26095.2 Lami Flange Frame Block Glass Skylights Sliding Glass Doors 55.0 65.0 CGI SGD-4130A FL29078.2 Lami Flange Frame Swing Type Doors 50.0 50.0 Therma-Tru Smooth Star FL20468.6 Lami French Doors Garage Doors Hurricane Protection Roof Ventilation N/A N/A O'Hagin Cloaked Vent 19-0109.02 REVIEWEp FOR Roofing Material N/A N/A GAF Asphalt Shin a FL10124-R27 ®DE Co 096)WE T 4 Revised 07/22/2014 — - — -g r n BOCC I have reviewed the above components or cladding and I have approved their use in this structure. These products Drovide adequate resistance to the wind loads and forces specified by current code provisions. 1EOFFCOR Digitally signed by Scott y`. Blakeslee Disher Scott Disher P. DN:cn=Scots Blakeslee Name: Signature: Disher, 9/17/20 osg,� Architect AR 11586 `aw REOPa email=sdisher@archstudiofl.c Design Prof: Cert. No. Date: w�` „ gW om, c=us Date: 2020.09.1811:31:43 -04'00' E Copy Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance FILE COPY Project Name: Single Family Model Residence Project Address: 5504 Deleon Avenue Permit #: Occupancy Type: R-3 Construction Type: IV INSTRUCTIONS FOR USE: This certification must be completed, signed, and sealed by the design professional of record. Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition REVIEWED FOR o Any accessory structure requiring a g D sOM PLQA CE o Any non-residential structure. �.�.` ����� �� * Note: Form not required for interior renovations rovided a no a r rr r ra elements are affected and certain minor building permits at the discretion of the local bullAw.'Contact the # above for questions. .DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Sixth Edition with 2017 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: ft S. Mean Roof Height 13.416 ft Roof Pitch: 4 :12 Parapet. N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): N/A p, o — 2. N/A one N/A =41M/-45.01�5.03/42.63 Garage: 35.03/ 42.63 7. Design Loads: Floor: 100 TTL PSF Roof/Dead:15 TC PSF Roof/Live: 30 TC Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: 40 PS F:.nCe N/A PSF Railings: 200 CL PSF 0 Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 1a Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Scott Disher Print Name Cert # & Co. Cert Auth. AR 11586 Signature, Date, and Seal Architectural Studio, Inc., Palm Beach Gardens, FL Company Name & Address Revised 12/07/2018