HomeMy WebLinkAboutBuilding Plansiq WINDOW SCHEDULE WINDOW SCHEDULE MARK TYPE STYLE NOTES WSIZ H +D.P'- 001 SH26 SINGLE HUNG T-1" 64" 40.40 43.92 002 PICTURE 24 PICTURE T-1" 4'-2 3/4" 41.50 45.01 OPAQUE 003 PICTURE 24 PICTURE T-1" 4'-2 3/4" 41.50 45.01 OPAQUE 004 PICTURE PICTURE T-0" 2'-0" 41.5 45.01 005 SH25 SINGLE HUNG T-0" 5'-0" 40.40 43.92 EGRESS 006 SH25 SINGLE HUNG 3'-0" 5'-0" 40.40 43.92 EGRESS 007 SH25 SINGLE HUNG T-1" 5'-3" 40.40 43.92 008 SH25 SINGLE HUNG T-1" 5'-3" 40.40 43.92 009 SH25 SINGLE HUNG T-1" 5'-3" 40.40 43.92 010 SH25 SINGLE HUNG T-1" 5'-3" 40.40 43.92 011 SH25 SINGLE HUNG 3'-1" 5'-311 40.40 43.92 EGRESS DOOR SCHEDULE MARK STYLE DOOR D.P. NOTES WD HGT + - 001 SINGLE EXTERIOR 3'-0" 8'-0" 39.02 42.54 NOTE #5 002 SINGLE 2'-8" 8'-0" 003 SLIDING DOUBLE 5'-0" 8'-0" 004 SINGLE 2'-8" 8'-0" 005 SINGLE 2'-811 8'-0" 006 SINGLE 2'-8" V-0" 007 SINGLE 2'-8" 8'-0" 008 SINGLE 2'-6" 8'-0" 009 SINGLE 2'-6" 8'-0" 010 BIFOLD 1'-6" 8'-0" 011 SLIDING DOUBLE EXTERIOR 6-0" 8'-0" 37.15 40.67 012 SINGLE 2'-0" 8'-0" 013 SINGLE 2'-6" 8'-0" 014 SINGLE 2'-8" 8'-0" 015 BIFOLD 2'-4" 8'-0" 016 SINGLE 21-4" 8'-0" LOUVERED 017 SINGLE 2'-8" 8'-0" NOTE #2 018 OVERHEAD 16--0" T-0" 35.03 42.00 NOTE5: I. ALL WINDOW 4 DOOR GLAZING TO BE LOW-E.- NON IMPACT - (IMPACT OPTIONAL) 2. 6ARA6E ENTRY DOOR SHALL BE SOLID WOOD DOOR NOT LESS THAT 1-515" IN THICKNESS, SOILID OR HONEYCOMB -GORE STEEL DOOR NOT LESS THAN 1-5/b" THICK OR 20 MIN. FIRE FATED DOOR, EQUIPPED WITH SELF- GL051N6, DEVICE. PER FBG-R5023.1 5. VERIFY ALL OPENING PRIOR TO MANUFAGTURIN6 WINDOW 4 DOORS. 4. ALL EXTERIOR WALL OPENIN65 IN EUWIN66 (DOORS, WINDOWS) WILL BE FILLY PROTECTED WITH IMPACT RESISTANT COVERINGS - 51-lUTTERS. S. WITH ALUMINUM THRESHOLD: DE51(SNATED EMIERS-ENCY MEANS OF ESCAPE PER FB.G 2011. Category /Subcategory PA # or NOA# Manufacturer Model Number Product Design Pressures Exterior Doors W I-) Swinging FL 20468.6 Therma-Tru Smooth Star 50.00 50.00 Sliding FL 29078.2 CGI Windows and Doors SGD-4130A 55.00 65.00 Sectional 16 x 7 FL 16107.38 Clopay GD4L 2 CAR W6 38.00 42.00 Sectional 16 x 7 FL 16107.3 Clopay 73 2 CAR W6 36.00 42.00 Windows Single Hung FL 23358.2 CGI Windows and Doors SH-4100A 55.00 65.00 Fixed FL 26095.2 CGI Windows and Doors PW-4120A 55.00 65.00 Mullion 18-0129.08 CGI Windows and Doors Series Clipped 90.00 90.00 Roofing Products Roofing Tiles FL7473.1 Eagle Roofing Products Concrete tile�OeN N/A Underlayment FL9777.1 Owens Corning Weatherloek G N/A Roof Vents 19-0109.02 O'Hagm Manufacturing, LLC O'Hagin's Cloaked Ve N/A 0 ►A 21'-f M:oM ---------_ - �- ' DINING LANAI 011 W-4" CL6. O 9'-4" GL6. - -`9 Q FAMILY 5 6 ROOM m 006 d) WNERS SUITE 9'-4' GL6, 10 13'-5" 20'-0" 4 ISLAND I COUNTER O 36' AFF. KI HEN REFJ 07 m p m I I 17:11 1 DW I DBL. SINK KOISPOSAL n� GL6. FREEZ. 2'_4" -b 4" b' nn.RANGE Ib' 6" W/MICRO 4 4'-4" iv TH INERS 0 ABV. O - - - O - - ry RY 9 SHV5. GL6 IR-15 - WIC 015 BEDROOM 9' 4" 3 G. s3 010 I i i I I 11 o Z. 325C I L" �r R-15 WIC LINEN - 5 S. IGALLERYI I 9'-4- to 10--0- 1 COFF. GL6. I 1 013 I " 014 - • I I Illy 4'-10" I 1 I® 016 ry r `� U1BATH 9'-4' 2 GL6. 005 L--- II to 017 O • Y LAUND 004 I'-b" 4'-8" 3'-4" 4'-10" Ob'-b" 2 DRYER O Q g a g 1 ZI I 1 I ( FOYER W-4" GL6. LN4f=G.LT. ATM AC45EV INSULATE WALL5 PANEL 'A' BUILD OUT ON TAIL E_D r E - - - - w PV R-II MIN. BATTS (TYP) 002 2 CAR GARAGE N y6'-10° 003 O 3'-4° GL6. O n BED OOM 2 - LINE OF 6ARA&E DOOR ABOVE - - - - 001 I PROVIDE 6ARA6E VENTILATION PER FMG T VENT IN 6ARA6E DOOR VENTILATION MEETS 5.1.1 THE 1 REQUIRED VENTS ALONG GARAGE DOOR PE ZIMETER. PORCH I I 1114. GL6. � I I I I I I designed drawn LTH checked 550 date Ob/01/20 (PERMIT SET) - scale 1/4" = I' -ON (U•O.N) job no. IgO6ZI_SF-21.lh 8$ O a m Y� C L C i# 0 = 0 N U N ) L7 L _ N xs Scott Blakeslee Disher U (6 p AR-0011586 AA-0003285 N O d u) tT E � aQ oLL M� LL 1 umi cy N ' 0. U)tl 3 =1 p Y •(D 0 W z LU VJ LU UJ O G J_ Q in 1 Lj J LL Q O W Lli Z LLJ LU J w wp w n- U) (D z C-4 FEE c N M L0 U- -0 project REVIEWED CHITECT RAL CODE COMPL ST. LUCIE COC W BOCC Architecture Q Planning 300 Avenue of Champions 260 FILE ^ Suite R>�Beach Gardens, Florida 33418 Phone 561.202.6990 Fax 561.296.2494 archstudio0.com drawing FLOOR PLAN sheet A-1 GENERAL NOTES FOUNDATION NOTES MASONRY NOTES PLAN NOTES (GONT'D) ELECTRICAL NOTES I. FLOOR SLAB TO BE 4" THICK POURED CONCRETE SLAB WITH 6" X 6" X WIAXWI.4 S. STRUCTURAL WOOD AND TIMBER FRAMING SHALL CONFORM TO THE "TIMBER I. TYPE OF GONSTRIIGTION: CLASS V, UNPROTECTED, GROUP R3 OCCUPANCY PER I. CONCRETE UNITS TO BE ASTM G g0-14. ASTM GRADES NI OR NIT. PROVIDE PRECAST I. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED I. CONTRACTOR SHALL VERIFY WITH F.P.dL. THE LOCATION OF SERVICE AND SHALL FLORIDA BUILDING CODE 2011. HA.M. ON 6 MIL VISQUEEN (OR EQUAL) ON GLEAN PELL COMPACTED FILL. MA SHALL LINTELS AS NECESSARY. On = 1500 P51) FOR REINSPEGTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN GON5TRUGTION MANUAL' AS PUBLISHED BY THE AMERICAN INSTITUTE OF TIMBER LOCATE METER d PANELS AS REWIRED.BE LOCATED IN THE MIDDLE TO UPPER HALF OF THE SLAB DEPTH AND MUST BE SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRICAL PANEL. CONSTRUCTION. 2. GONL5TRUGTION SHALL FOLLOW THE FLORIDA BUILDING GORE AS ADAPTED BY THE SUPPORTED AT 3'-0" O/C EACH WAY WITH APPROVED MATERIALS. 2. MORTAR TYPE M PER ASTM C 210-12a 2. ALL WIRE SHALL BE THHN COPPER. UNLE55 NOTED OTHERWISE. COUNTY AND ALL APPLICABLE AMENDMENTS. 2. PROVIDE 3" STEEL POST OR BOLLARD OR TIRE BUMPER IN FRONT OF ALL EQUIPMENT 1. ALL WOOD IN CONTACT WITH MA50WY OR CONCRETE SHALL BE PRESSURE TREATED. 2. PROVIDE A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN 3. ASTM C416 GROUT PROVIDE AN APPROVED M015TURE VAPOR BARRIER BETWEEN THE CONCRETE OR OTHER (HVAG, ECA CO ER/bRYERI LOCATED IN THE GARAGE AT FLOOR LEVEL PER FB.G. 5. WHERE REQUIRED BY OTHER CODES, SERVICE AND FEEDER CONDUCTORS SHALL BE 3. BUILDER SHALL COORDINATE ALL THE WORK OF ALL TRADES. TERMITES. TREATMENT SHOULD BE IN ACCORDANCE WITH THE RULES AND LAWS MECHANICAL GORE. GEMENTITOUS MATERIALS AND THE WOOD AS PER CODE. COPPER OF EQUAL AAPACITY. ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER A. CELLS LINTEL-5 AND BOND BEAMS WHERE SPECIFIED SHALL BE FILLED W/ 2500 4. BUILDER SHALL REVIEW DRAWINGS IN THEIR ENTIRETY BEFORE STARTING WORK. THE SERVICES. PSI ASTM 6416 6ROUT. 5. PROVIDE Ix2 P.T. FIRE5TOP VERTICALLY AT THE CEILING AND FLOOR LEVELS. 10. BUILDER SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE BRACING AND 4. ALL BRANCH CIRCUITS IN RACEWAY OR NON METALLIC SHEATHED GABLE. BUILDER SHALL ACCEPT FULL RE5PON5ABILITY FOR ANY ERRORS OR OMISSIONS NOT HORIZONTALLY AT INTERVALS NOT EXCEEDING 10'-0", AND ALL OTHER LOCATIONS PER BRIDGING USED DURING ERECTION OF TRUSSES AND STRUCTURAL 5LAB5 TO PREVENT REPORTED IMMEDIATELY IN WRITING TO THE ARCHITECT. 5AGKGHAR6E5 WILL NOT BE 5. ALL REINFORCING STEEL TO BE CRAVE 60. B. THE MIX DE51ON SHALL BE APPROVED BY THE ENGINEER F.B.G. SECTION R302.11. COLLAPSE OR DAMAGE. 5. COORDINATE RACEWAY INSTALLATIONS WITH OTHER TRADES PRIOR TO ACCEPTED.. DO NOT SCALE DRAWINGS. 4. COLUMN AND WALL CENTERLINES SHALL COINCIDE WITH FOOTING CENTERLINES UNLESS 11. HEADERS FOR FRAMED OPENINGS GREATER THAN 6'-0" MUST BE EN&NEERED AND CONSTRUCTION. OTHERWISE NOTED. G. ALL CONCRETE SHALL BE OF A FLUID CONSISTENCY WITH A SLUMP OF q"-II" MAX., 4. ALL GLAZING WITHIN 24" OF EITHER SIDE OF THE DOOR PLANE IN A CLOSED POSITION 5. SUBMIT MINIMUM THREE (5) COPIES OF SHOP DRAWINGS A5 REQUIRED BELOW. EWHICH MEANS THAT THE CONSISTENCY SHALL BE AS FLUID AS P0551BL.E FOR AND ON A HALL PERPENDICULAR TO THE PLANE OF THE DOOR ON THE HINGE 51DE OF THE STAMPED BY THE TRU55 MANUFACTURER (UNLESS NOTED OTHERWISFa 6. VERIFY ALL CONDUCTORS AND BREAKERS WITH EQUIPMENT MANUFACTURER FRAME CONSTRUCTION DEPENDING ON ALL H 5. FOOTING DESIGN BASED ON ASSUMED 501L BEARING CAPACITY OF 2500 P.S.F., POURING HITHOUT SEGREGATION OF THE CONSTITUENT PARTS. DOOR (46" IN HVHZ) SHALL BE TEMPERED. ALL WINDOWS OR GLASS ENCLOSURES AT OR SPECIFICATIONS. 6. THESE PLANS, AS DRAWN AND NOTED, COMPLY WITH THE BUILDING ENVELOPE WITHIN 36" OF TUBS AND 5HONER5 WITH SILLS LE55 THAN 60" ABOVE FLOOR SHALL BE 2. ALL HEADERS OVER DOORS AND WINDOWS TO BE (2) OR (3) 2XI25 UNLESS CONTRACTOR TO SUBMIT SOIL BEARING TEST RESULTS OR SOIL BEARING CAPACITY OD ALL 1. PROVIDE DISCONNECT SWITCH OF SIZE AS REQUIRED BY LOAD AND UNITS. ENERGY REQUIREMENTS OF THE F.B.C. GRAFTER 13 ENERGY EFFICIENCY. CONTRACTOR D. THE USE OF ADMIXTURES SHALL NOT BE PERMITTED WITHOUT WRITTEN CONSENT OF TEMPERED. ALL GLASS IN 51DELI6HT5, SLIDING GLASS DOORS AND FRENCH DOORS OTHERWISE NOTED. (FOR WO SHALL FAMILIARIZE HIMSELF WITH THE GOVERNING CODE IN ITS ENTIRETY AND BUILD REPORT BY A FLORIDA REGISTERED ENGINEER. THE ENGINEER SHALL BE TEMPERED. THICKNESS). IN ACCORDANCE WITH ALL PROVISIONS OF TH15 CODE WHICH MAY NOT BE bALL 511E PREPARATIONS d DRAINAGE RECOMMENDATIONS MADE IN THE SITE 5. PROVIDE NON -FUSIBLE GENERAL DUTY SAFETY SWITCHE5 AT A/C EQUIP. AND AT . SPECIFICALLY ADDRESSED ON THE PLANS AND NOTES. 4. REINFORCING: S. EGRESS WINDOWS SHALL BE OPERABLE FROM THE IN51DE WITHOUT THE USE OF TOOLS. 13. DIMENSIONAL LUMBER SHALL BE SOUTHERN PINE. NO. 2 OR BETTER AND SHALL FUMF5 NOT VISIBLE FROM CIRCUIT BREAKER PANEL AND AS PER MANUFACTURER. SPECIFIC 6EOTECHNICAL REPORT MUST BE STRICTLY ADHERED TO. EGRESS WINDOV5 SHALL HAVE A MINIMAL NET OPENING OF 24" HIGH, 20' WIDE, AND MIN. PROVIDE ALLOWABLE STRESS VALUES OF 1200 P51 IN BENDING FOR A SINGLE MEMBER RECOMMENDATIONS. 1. BUILDER 15 RESPONSIBLE FOR ADEQUATE BRACING OF STRUCTURAL OR VERTICAL: NET AREA OF 5.1 S.F. FOR 21d FLOOR WINDOWS AND 5.0 S.F. FOR Ist FLOOR WINDOWS. USES. q0 PSI IN HORIZONTAL SHEAR AND 5HALL HAVE A MODULES ELASTICITY OF 1600 NON-STRUCTURAL MEMBERS DURING CONSTRUCTION. C FILLEAN PEALED WITHIN 5'-0' OF THE CONSTRUCTION PERIMETER SHALL CONSIST OF THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" ABOVE THE FLOOR, LATCH KSI OR BETTER, AS DETERMINED BY AN APPROVED LUMBER GRADING AGENCY. q. PROVIDE 6F01 PROTECTION FOR ALL BATHROOM, GARAGE, EXTERIOR, KITCHEN, GLEAN WELL GRADED SAND IN 12" MODLIFIFIED PROCTAX)OR AND VIBRATORY COMPACTED TO A. ASTM A615/A 615M-12. PER REINFORGIN& SECTION (GRADE 60). AT 54" A.F.F. MAX. IN HVHZ AREAS WHERE THERE 15 MORE THAN A 4'-0' DROP, THE SILL LAUNDRY AND WET BAR OUTLETS PER NEC 210.6(A). 8. CABINET SUPPLIER TO PROVIDE SHOP DRAWINGS TO THE BUILDER. ACHIEVE A MINIMUM OF 95% MODIFIED PROCTOR ASTM D 1557LIRE SHALL BE NO LESS THAN 56' A.F.F. OR PROVIDE AN APPROVED SAFEGUARD. 14. NON -BEARING INTERIOR PARTITIONS MAY BE CONSTRUCTED OF 25 GAUGE GEE 8. AFTER STANDARD GLEANING AND 6RU(BBING HAS BEEN COMPLETED AND APPROVED, B. WHEN A FOUNDATION DOWEL DOES NOT LINE UP WITH A VERTICAL GORE, IT SHALL NOT CHANNEL TYPE STUDS AT 24` 0/0 WITH MATCHING TRACKS TOP AND BOTTOM, WITH 1/2" 10. ELECTRICAL FIXTURES, TRIM AND APPLIANCES SHALL BE UL APPROVED AND AS q. WINDOW AND DOOR SUPPLIER TO PROVIDE SHOP DRAWING TO BUILDER. BE SLOPED MORE THAN ONE HORIZONTAL IN 51X VERTICAL ALIGNMENT, EVEN THOUGH IT 15 6. ALL BATHROOM FLOORS SHALL BE OF APPROVED IMPERVIOUS MATERIALS. GYPSUM DRYWALL EACH SIDE. ATTACH ORYHALL WITH I' LONG BUGLE HEAD DRYWALL SELECT P BY OWNER APPLY VIBRATORY COMPACTOR WITH A MINIMUM OF FOUR PASSES TO THE EXISTING IN AN ADJACENT CELL TO THE VERTICAL WALL REINFORCING. 5CREH5 AT 12" O/c; MAX. 10. ALL WINOOW5 AND DOORS SHALL BE CAULKED AND WEATHER STRIVED. WINDOW GROUND. b. IN HVHZ AREAS PROVIDE HURRICANE SHUTTERS AS PER FB.C. SECTION 24-15 UNLE55 11. PROVIDE PRE -WIRED TELEPHONE, T.V. OUTLETS OUTLETS AS SHOWN ON PLAN. UNITS SHALL DISPLAY LABELS 5HOWING COMPLIANCE WITH THE F.B.G. ENERGY q SLABS SHALL NOT BE LOADED UNTIL 12 HOURS HA5 ELAPSED. C. VERTICAL REINFORCING STEEL SHALL HAVE A MINIMUM CLEARANCE OF ONE-HALF INCH THE EXTERIOR WALL COMPONENTS OF THE ENCLOSED BUILDING HAS SPECIFIC PRODUCT 15. METAL LATH OVER 5HEATHIN6 SHALL BE 50' V-&ROVE OR DIMPLED. CEILINGS AND CONSERVATION CODE. FROM THE MASONRY. APPROVAL TO PRESERVE THE ENCLOSED BUILDING ENVELOPE AGAINST IMPACT LOADS SOFFITS SHALL BE HIGH RIB TYPE. FASTEN TO 5UBSTATE AT 4" OX AS FOLLOWS; 12. ALL CLOSET LIGHTING SHALL COMPLY WITH NEC, SEC. 410.8. 11. ALL CONSTRUCTION IN BROWARD AND DARE COUNTIES SHALL COMPLY WITH THE 10. SPLICES SHALL BE 4& BAR DIAMETERS AND CONTINUOUS AROUND ALL CORNERS AS SET FORTH IN CHAPTER 16. CONCRETE: 5/4" LONG STUB NAILS H/ 50' HEAD. HORIZONTAL AND VERTICAL WOOD AND CHANGES IN DIRECTION. CORNER BARS SHALL BE 48 BAR DIAMETERS EACH. WAY. D. VERTICAL REINFORCING SHALL BE A5 LOCATED ON THE PLAN AND AS INDICATED IN FRAMING MEMBERS H/ NAILS OR STAPLES TO PROVIDE AT LEAST 1-1/4" PENETRATION 15. THE BRANCH CIRCUITS CONTAINING SMOKE DETECTORS SHALL HAVE ARC -FAULT HIGH VELOCITY HURRICANE ZONE (HVHZ) SECTIONS OF THE F.B.C.THE COLUMN SCHEDULE. 11. PICKETS AT STAIRS, LANDINGS d BALCONIES SHALL BE SPACED TO PREVENT INTO HORIZONTAL WOOD FRAMING MEMBERS, AND 3/4' PENETRATION INTO VERTICAL PROTECTION PER NEC SE0.210.12 SMOKE DETECTORS SHALL BE CONNECTED TO 11. ALL MONOLITHIC FOOTINGS HAVE BEEN CHECKED FOR THE USE OF TRANSFER PASSAGE OF A 4" DIAMETER SPHERE. WOOD FRAMING MEMBERS. ON VERTICAL WOOD FRAMING MEMBERS, COMMON NAILS ARC -FAULT CIRCUITS AHEAD OF SWITCH AND HAVE SELF CONTAINED BATTER BACK-UP. REINFORCEMENT AT THE PERIMETER. RATIONAL ANALYSIS SHALL BE SUBMITTED, BUT E. VERTICAL REINFORCING EACH SIDE OF ANY OPENING, IF REQUIRED, SHALL BE SHALL BE BENT OVER TO ENGAGE AT LEAST THREE STRANDS OF LATH, OR BE BENT DETECTORS SHALL BE TANDEM WIRED 50 ALL DETECTORS SOUND SIMULTANEOUSLY. THE BUILDING OFFICIAL. TO THE TIE BEAM. PRECAST LINTELS SHALL HAVE OPENINGS TO ALLOW 10. PROVIDE A MINIMUM OF 4' CLEAR ALL AROUND AIR HANDLER UNITS. OVER A RIB WHEN RIB LATH 15 INSTALLED. SHEATHING: 14 GAZE STAPLES I" LE6,1/16" SITE PLAN NOTES ONLY IF REQUESTED REINFORCING BARS TO CONTINUE UNINTERRUPTED. CROHN METAL MTL. FRAMING: SELF TAPING SCREWS •12 x 1/2' WASHER HEAD STAPLES 14. PRE -WIRE FOR GARAGE DOOR OPENER SENSOR. 12. CONCRETE FOR FOUNDATIONS AND FOOTIN65 SHALL BE 2500 PSI MIN. 11. IN ZERO LOT LINE HOMES: DRYER VENT5, EXHAUST FANS d KITCHEN HOODS SHALL NOT SHALL NOT BE USED FOR SOFFITS OR CEILINGS 1, THE ARCHITECTURAL SITE PLAN, IF PROVIDED IN THESE DOGUMENT5 15 FOR GENERAL MAXIMUM HATER/CEMENT RATIO MUST NOT EXCEED 0.65. HORIZONTAL: VENT THROUGH THE SIDE HALL AND MUST MAINTAIN A 10'-0" SETBACK. 15. PROVIDE ARC -FAULT CIRCUIT INTERRUPTER PROTECTION IN DWELLING UNIT LIVING, LOCATION OF THE HOUSE, POOL, DRIVEWAYS AND SITE FEATURES ONLY. THE S.C. OR 16. WHERE CEMENT PLASTER 15 APPLIED TO LATH OVER FRAME CONSTRUCTION, BONDING DINING, FAMILY ROOMS, DENS/ LIBRARIES, BEDROOMS, SUNROOM5, CLOSETS, HALLWAYS, OWNER SHALL PROVIDE A PRELIMINARY LOT FIT PERFORMED BY A LICENGED A. HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SCHEDULED IN THE BEAM OF THE PLASTER TO THE HATER BARRIER SHALL BE PREVENTED BY PROVIDING A DEL. KITCHEN AND LAUNDRY ROOMS OR SIM. ROOMS PER NEC 210.12. SURVEYOR AT 50 FEGENT COMPLETION OF PROJECT. THE SURVEYOR 15 RESFON51BLE BEAM SCHEDULE NOTES SCHEDULE LAYER OF WATER BARRIER OR BY INSTALLING A HOUSE WRAP BENEATH THE WATER FOR VERIFYING BUILDING LOT FIT, LOT COVERAGE, EASEMENT LOCATIONS, SET BACKS, FRAMING NOTES BARRIER. 16. SMOKE DETECTORS: AND ALL SITE DIMENSIONS PRIOR TO PERMIT AND CONSTRUCTION. IF ANY CONFLICTS B. HORIZONTAL JOINT REINFORCEMENT SHALL WN515T OF AT LEAST q GAGE LADDER 16.1. REQUIRED ON ALL HVAG UNITS WITH 2001 GFM OR MORE. OCCUR BETHEEN THE ARCHITECTURAL SITE PLAN AND SURVEYORS LAYOUT THE GENERAL TYPE REINFORCEMENT SPACED NOT MORE THEN 16" O/G VERT. REINFORCEMENT SHALL 1T PNEUMATIC FASTENERS SYSTEM TO BE HILTI-COIL NAIL PROGRAM. TYPE TO BE GRF 162. CEILING AREA: 110 V. SMOKE ALARMS SHALL BE INSTALLED NOT LE55 THAN 5 FEET I. SCHEDULED HOOPS AND STIRRUPS SHALL BE PLACED AT EACH END (E.E) OF BEAM OR ALSO BE PROVIDED AT THE BOTTOM AND TOP OF ALL OPENIN66 AND EXTEND NOT LESS 1126 1-1/2' LONG AND .120" DIAMETER U.N.O. HORIZONTALLY FROM THE DOOR OR OPENING OF A BATHROOM THAT CONTAINS A CONTRACTOR AND ARCHITECT SHALL BE NOTIFIED IN WRITING PRIOR TO PERMITTING I. THE TiU55 AND FLOOR SYSTEM LAYOUT SHOWN ON THIS SHEET IS SCHEMATIC IN THROUGHOUT (TA) BEAM AS INDICATED ON BEAM SCHEDULE. STIRRUPS SHALL BE TYPE THEN 24" BEYOND THE OPENING. PROVIDE 8 MIN EMBEDMENT INTO CONCRETE COLUMNS BATHTUB OR SHOWER UNLE55 THIS WOULD PREVENT PLACEMENT OF A SMOKE ALARM AND EVES TEES C FL WORK SHALL BE PERFORMED UNTIL THE GENERAL CONTRACTOR NATURE. HOWEVER, THE SUPPORTING SUPERSTRUCTURE HAS BEEN PARALLEL UNDER THE 5-6 AND HOOPS SHALL BE TYPE T-2 TYPICAL GR51 BAR BENDS UNLESS OTHERWISE AND BEAMS AND FULL DEPTH LAPS AT ALL MASONRY "L" AND `T" INTERSECTIONS. I6. WHEN WOOD POSTS ARE NOT IN A FIRERATED WALL, FIRE RATE POST AS FOLLOWS: REQUIRED BY SECTION R314.5. RESOLVES THESE CONFLICTS. ASSUMPTION THAT THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRU55 WRAF POST ON ALL SIDES FROM BASE OF POST TO UNDERSIDE OF BEARING WITH (U NOTED. 16.3E NEAR COOKING APPLIANCES. SMOKE ALARMS SHALL NOT BE INSTALLED IN THE AND FLOOR SYSTEM DESIGNERS LAYOUT. LAYER OF SW TYPE 'X" GYPSUM WALL BOARD. THIS WILL PROVIDE A ONE HOUR RATING CONCRETE NOTES 5 GENERAL. FOLLOWING LOCATIONS UNLESS THIS WOULD PREVENT PLACEMENT OF A SMOKE 2. ALL BEAM (MARK "B"} TOP BARS SHALL BE CONTINUOUS UNLESS OTHERWISE NOTED FOR THE POST. ALARM IN A LOCATION REQUIRED BY SECTION R314.3. A. STRUGTRAL DESIGN 15 IN ACCORDANCE WITH A.G.I. 530-13/ A.S.GE2. THIS FRAMING SCHEME (DIRECTION OF TR055E5 AND . 5-13/T.M.S. 402-Ib, SLABS, MAJOR G.T. BEARING -IONIZATION SMOKE ALARMS NOT BE INSTALLED LE55 THAN 20 FEET HORIZ. FROM 5. ALL TIE BEAMS (MARK "T3") REINFORGIN6 SHALL BE CONTINUOUS THROUGH TIE- BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY ON POINTS, ETC) CAN BE MODIFIED ONLY AFTER OBTAINING PERMISSION FROM THE PRIME 14. TRUSS MANUFACTURER SHALL DESIGN TRUSSES TO COMPLY WITH ALL SUPERIMPOSED A PERMANENTLY INSTALLED COOKING APPLIANCE. I. CONCRETE SHALL CONFORM TO ASTM Gq4/G q4M-Oq, SHALL HAVE A MAXIMUM PROFESSIONAL OF RECORD WHO MUST REVIEW PROPOSED CHANGES AND AUTHORIZE WIND LOADS PER FB.G. 2011E BEAMS ONLY. ALL SPLICES TO BE A MINIMUM OF 4B BAR DIAMETERS. BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES. -IONIZATION SMOKE ALARMS WITH AN ALARM-51LENGING SWITCH SHALL NOT BE WATER/CEMENT RATIO OF Ob5 AND SHALL HAVE 5000 PSI COMPRESSIVE STRENGTH IN STRUCTURAL REVISIONS ACCORDINGLY. INSTALLED LE55 THAN 10 FEET HORIZ. FROM A PERMANENTLY INSTALLED COOKING 2b DAYS ( UNLESS NOTED OTHERWISE) ALL CONCRETE WORK SHALL BE IN ACCORDANCE 4. BUNDLE ALL STRUCTURAL BEAM TOP BARS IN PAIRS OVER SUPPORTS WITH TOP BARS B. CONSTRUCTION SHALL BE IN ACCORDANCE WITH A.G.I. 530.1-15/A.S.L.E. 6-15/T.M.S. APPLIANCE. WITH AGI 518-14 AND AGI 501-10. ALL CONCRETE MASONRY WORK SHALL BE IN FROM ADJACENT BEAMS. (UNO). 602-I6, SPECIFICATIONS FOR MA50NRY STRUCTURES AND THE COMMENTARY ON 3. FINAL SIGNED AND SEALED ENGINEERED TRU55 AND FLOOR SYSTEM DESIGN MUST BE MECHANICAL NOTES - PHOTOELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED LESS THAN 6 FEET ACCORDANCE WITH AGI 550-15. SPECIFICATIONS FOR MA50NRY STRUCTURES. SUBMITTED TO TH15 OFFICE FOR REVIEW. TRUSS AND FLOOR SYSTEM PM15NERS MUST HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. 5. DROP BOTTOM OF TIE BEAMS AS REQUIRED AT WINDOW d DOOR HEADS (26" MAX) PROVIDE ALL TRUSS CONNECTIONS A5 PART OF THE DESIGN. 2. MINIMUM CONCRETE COVER OVER REINFORCING SHALL BE: SLABS ON VAPOR ALL HEATING, AIR CONDITIONING, REFRIGERATION AND VENTILATION EQUIPMENT SHALL ADD 245 BOTTOM IF DROP EXCEEDS 6". G. IN HVHZ AREAS THE BUILDER SHALL EMPLOY A SPECIAL INSPECTOR APPROVED BY THE 1. CARBON MONOXIDE ALARM TO BE INSTALLED WITHIN 10' OF A ROOM USED FOR CONFORM TO THE REQUIREMENTS SET FORTH IN THE "FLORIDA BUILDING CODE BARRIER - 3/4" BEAMS AND COLUMNS - I I/2" FORMED CONCRETE BELOW GRADE-2 BUILDING OFFIGAL TO ENSURE COMPLIANCE WITH THE APPROVED STRUCTURAL PLANS IN 4. TRUSS AND FLOOR ENGINEERING MANUFACTURER SHALL SUBMIT THREE Y COPIES OF SHOP SLEEPING FUW05M HHEN THE BUILDING 14M A F0551L BURNING HEATER OR APPLIANCE, UNFORMED CONCRETE BELOW GRADE-3" ACCORDANCE WITH SECTION 2122.2.4 F.B.G. DRAWINGS AND ENGINEERING CALCULATIONS SIGNED AND SEALED BY A FLORIDA MECHANICAL" AND FLORIDA BUILDING CADS ENERGY CONSERVATION . A FIREPLACE, OR AN ATTACHED GARAGE. PRIMARY POWER SHALL COME FROM THE 6. TIE BEAM SCHEDULE DEPTHS ARE MINIMUM AND MAY BE INCREASED 8" TO FIT BLOCK REGISTERED ENGINEER, OF THEIR DESIGN FOR REVIEW INCLUDING T"10 (2) COPIES FOR BUILDING WIRING WHEN SUCH WIRING 15 SERVED BY THE LOCAL POWER UTILITY. SUCH 3. REINFORCING STEEL: GRADE 60 (FY=60.000) AST"1 A615/A 6I5M-Oq. WORK. 6. VERTICAL CELLS FOR MASONRY TO BE GROUTED SHALL HAVE VERTICAL ALIGNMENT ARCHITECT/ EN61NEERS REVIEW PRIOR TO FABRICATION. REVIEW OF SHOP DRANIN65 15 2. A 4" CLEARANCE 15 TO BE MAINTAINED AROUND ALL AIR HANDLING UNITS. ALARMS SHALL HAVE BATTERY BACKUP. IF USED, A COMBINATION SMOKE/ CARBON 1. ALL ADDED L06ITUDIN AL BEAM REINFORCN6 SHALL EXTEND 6" MINIMUM INTO SUFFICIENT TO MAINTAIN A CLEAR, UN055TRXTED CANT. CELL. A COURTESY BY THE ARCHITECT/ ENGINEER AND IN NO WAY RELIEVES THE MONOXIDE ALARM SHALL BE LISTED OR LABELED BY A NATIONALLY RECOGNIZED 3. PROVIDE FIRE DAMPERS AT SUPPLY AND RETURNS WHICH PASS THROUGH RATED 4. DETAIL OF CONCRETE REINFORCEMENT SHALL BE IN ACCORDANCE WITH "THE MANUAL SUPPORT UNLESS OTHERWISE NOTED. MANUFACTURER OF HIS RESPONSIBILITY TO PROVIDE A LAYOUT THAT FULLY A55ENffiLIES IF ANY. TESTING LABORATORY. OF STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION" AS PUBLISHED 1. CLEANOUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM OF GROUTED CELLS AT INTEGRATES HITH THE ARCHITECT/ ENCINNERS SUPERSTRUGTURE. IF THERE 15 ANY BY THE CONCRETE REINFORCING STEEL INSTITUTE UNLESS NOTED OTHERWISE. S. REFER TO CONCRETE NOTES FOR INFORMATION ON CONCRETE AND STEEL EACH LIFT OVER 4'-0" HIGH. GLEANOUT5 SHALL BE SEALED AFTER GLEANING AND CONFLICT OR ADDITIONAL STRUCTURE NEEDED, THE TW55 AND FLOOR SYSTEM 4ALLWEL 16. TAMPER RE515TANT REGEPTAGLE5 ARE REQUIRED IN DNELLIN6 UNITS IN ALL AREAS . DLING ROOMS MUST HAVE HVAG RETURNS. RETURNS MAY BE DUCTED, SPECIFICATIONS. INSPECTION, AND BEFORE GROUTING. COMPANY SHALL NOTIFY THE ARCHITECT/ ENGINEER IN WRITING OF THE SPECIFIC SPECIFIED IN NEC 21052 FOR 125 VOLT, IS d 20A RECEPTACLES PER NEC 406.11 5. ADEQUATE VERTICAL AND HORIZONTAL SHORING SHALL BE PROVIDED TO SAFELY AREAS OF CONCERN. JUMPERS OR TRANSFER GRILLES. SUPPORT ALL LOADS DURING CONSTRUCTION, q. ONE-OUARTER OF MAXIMUM BOTTOM REINFORCING STEEL AREA OF EITHER ADJACENT STEEL NOTES 5. A/o UNITS MAY HAVE CONC. PAD OR OTHER APPROVED MATERIAL EXTENDING ABV. 14. INTERSYSTEM BONDING TERMINATION FOR CONNECTING INTERSYSTEM BONDING AND BEAM SHALL EXTEND THRU SUPPORT AND LEAP WITH A CLASS "A' TEN51ON LAP 5PLIGE 5. TRU55E5 TO BE LOCATIONS HI TO CARRY LOADS OF ATTIC ATI AND MISC. EQUIPMENT. ADJOINING GRADE OR SHALL BE SUSPENDED A MIN. OF 6' ABV. ADJOINING GRADE. GROUNDING CONDUCTORS SHALL BE PROVIDED FOR TV, COMMUNICATIONS, RADIO, CATV, b. DOWELS COLUMN AND HALL REINFORCING TO FOOTING WITH SAME SIZE AND NUMBER ON EITHER 5117E OF SUPPORT. COORDINATE LOCATIONS WITH BUILDER PRIOR TO FABRICATION AND INDICATE ON ETC. PER NEC 250.g4. (A) OR (B) OF DOWELS AS VERTICAL BARS ABOVE. 1. STRUCTURAL STEEL SHALL CONFORM TO THE AISG "SPECIFICATION FOR THE DESIGN, TRU55 ORAWIN65.THE BUILDER SHALL BE RESPONSIBLE FOR THE COMPLETE PADS SHALL BE A MINIMUM 4'-O"xq'-0" PAD FOR DOUBLE UNIT. 10. MARK Boll IN REINFORCING COLUMN BETWEEN TWO BEAMS INDICATES THAT FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDIN65" . MATERIALS SHALL COORDINATION BETVSEN THE TRU55 DESIGN AND AIR CONDITIONING DESIGN 20. PER FBG-E 404.1 LIGHTING EQUIPMENT. A MINIMUM OF T5 PERCENT OF THE 1. REINFORCING STEEL SHALL BE LAPPED 4& BAR VIA. MIN. WHERE SPLICED AND SHALL REINFORCING SHALL BE CONTINUOUS THRU THESE TWO BEAMS. CONFORM TO THE APPLICABLE ASTM SPECIFICATION A5 FOLLOWS: W 5HAPE5 - AIA2/ II, REQUIREMENTS. LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE BE WIRED TOGETHER. PROVIDE CORNER BARS SAME SIZE AND NUMBER AS HORIZ. BEAM OTHER SHAPES - A56/A 56M-06, PLATES A36/A 56M-06, BOLTS - A 301-14 TUBULAR - PLUMBING NOTES HIGH -EFFICACY LAMPS. REINFORCING AT EACH FADE. LAP 48 BAR VIA. MIN. b. ARCHITECT NOR ENGINEER ACCEPTS ANY RESPONSIBILITY FOR STRUG'URAL BEAMS, ASTM A500/A50OM-15 GRADE B (46 K51) COLUMNS, AND FOOTINGS UNTIL REVIEW OF APPROVED TRUSS AND FLOOR SYSTEM 21. BOXES AT LUMINAIRE CUTLETS: BOXES USED AT LUMINAIRE OR LAMP HOLDERS IN A 6. PLACING DRAHIN66 ON BAR LISTS SHALL CONFORM TO ACI'S "MANUAL OF STANDARD DRAWINGS, 516NED AND SEALED BY A FLORIDA REGISTERED ENGINEER. I. ALL PLUMBING FIXTURES SHALL BE INSTALLED IN ACCORDANCE WIT14 SECTION 405, CEILING SHALL BE DESIGNED FO THE PURPOSE AND SHALL BE REQUIRED TO SUPPORT A PRACTICE FOR DETAILING REINFORCED CONCRETE CONSTRUCTION AS PUBLISHED BY THE 2. WELDED CONSTRUCTION SHALL CONFORM TO THE AMERICAN HELPING SOCIETY F.B.O. LUMINAIRE WEIGHING A MIN. OF 25K& (50 LB). NEC, 314.21A. CONCRETE REINFORCING STEEL INSTITUTE UNLESS NOTED OTHERHISE. "STRUCTURAL WELDING CODE". ELECTRODES FOR FIELD AND SHOP WELDS SHALL BE 1. ALL INTERIOR LOAD BEARING PARTITIONS TO BE CONSTRUCTED WITH CLIPS, TOP AND 2. ALL PLUMBING FIXTURES SHALL MEET THE REQUIREMENTS OF TABLE 6043, FB.C. A.W.S. A5.1 E1OXX. BOTTOM EACH STUD. 5. DISP051TION OF RAIN HATER SHALL COMPLY WITH F.B.C. PLUMBING CODE CHAPTER 11. 22.pRQVIDE ADEQUATE CLEARANCE FOR ELECTRICAL EQUIPMENT REQUIRING SERVICE WHILE 4. ALL PLUMBING PENETRATIONS MUST BE A MINIMUM 10'-0" FROM ROOF JACKS. ENERGIZED SUCH AS SERVICE EQUIPMENT, PANEL BOARDS, P15CONNECTS ETC. A5 PER NEC 11026 S. CONDENSATE DRAINS MUST BE A MINIMUM OF 12" OFF THE BUILDING. . ,• b. SHOWER COMPARTMENTS AND WALLS ABOVE BATH TUE35 WITH SHOWER HEADS SHALL 23.ALL CFI SHALL BE INSTALLED IN READILY ACCF5515LF LOCATIONS PER NEC 210A PROPOSED SINGLE FAMILY RESIDENCE BY: BE FINISHED KITH AEDRAT SMOOTH, INLET.NONABWRBENT SURFACE TO A HEIGHT NOT LESS THEN 10 INCHES ABOVE THE DRAIN INLET. 2 ST STREET, LLC. LOAD SCHEDULE CODES USED: ABBREVIATIONS LOCATION: LIVE DEAD TOTAL FLORIDA BUILDINGCODE 6THEDITION (2011) GROUND FLOOR 40 60 100 M.G. MEDICINE CABINET SM5 SHEET METAL SCREWS - FLORIDA BUILDING CODE - RESIDENTIAL bTH EDITION (2011) ABV ABOVE EXT. EXTERIOR SECOND FLOOR 40 25 65 AFF ABOVE FINISHED FLOOR F.B.C. FLORIDA BUILDING CODE M.R.H. MEAN ROOF HEIGHT 5T. STIRRUPS A14U AIR HANDLER UNIT F.R. FIRE RATED M.T. METAL THRESHOLD 5T-. STEEL TOP CHORD 40 20 NEC 2014 B.F. BI FOLD FIR FRENCH DOOR MAX. MAXIMUM SW SWITCH j BOTTOM CHORD 0 5 B.P. BI PASS FIN. FINISHED MFR. MANUFACTURER 5.W.O.T. 5HEARWALL OVERTURNING FORGE BALCONIES 60 25 85 -+�`•GEr7-10 BLK. BLOCK FL. FLOOR MICRO. MICROHAVE TEMP. TEMPERED ROOF 30 25 55 MIN BLH BELOW G.T. GIRDER TRUSS . MINIMUM TB. THROU6FI BOET 5412 BTD E L E O N AVE. TOP CHORD 50 15 DRAWING INDEX: STRUCTURAL BLA BEARING GA. OIRDGAUGE M.O. MASONRY OPENING T.O. THROUGH OUT MONO. MONOLITHIC, T.OBB. TOP OF MA50NRY BOND BEAM ' BOTTOM CHORD O 10 G-O OPTION SHEET 5-I FOUNDATION PLAN -COSTAL "I. BOTTOM GALV. GALVANIZED M. METAL T.O.PL. TOP OF WOOD PLATE BTM. CHORD -ATTIC 10 O G-I COVER SHEET 5-2 FRAMING d BRACING PLAN GL6. CEILING 6F1 GROUND FAULT INTERRUPT O.H.D. OVER HEAD DOOR T.O.TB. TOP OF TIE BEAM �U 5-3 FRAMING DETAILS CMU CONCRETE MASONRY UNITS &GLASO/c,ON CENTER TYP. TYPICAL I:.. COL. COLUMN 6H8 GYPSUM WALLBOARD O/c, CONC. CONCRETE GYP. W. GYPSUM WALLBOARD P.L.F. POUNDS PER LINEAR FOOT U.N.O. UNLESS NOTED OTHERWISE HIND.. ARCHITECTURAL GSMT. CASEMENT H&T. HEIGHT P.5.F. POUNDS PER SQUARE FOOT UL UNDERHRITER5 LABORATORIES ULTIMATE WIND SPEED = 160 mph. ELECTRICAL DEL. DOUBLE HP5. HOOPS F.S.I. POUNDS PER SQUARE INCH V.I.F. VERIFY IN FIELD PIA. DIAMETER HR HOUR P.T. PRESSURE TREATED WA. HEDGE ANCHORS - NOMINAL WIND SPEED = 124 mph. A -I FLOOR PLAN �CC``'',,ccx a,A �.... 0I5P. DISPOSAL H5 HORIZONTAL SLIDING PARTR PARTITION H/ WITH *- RISK CATEGORY = II A-2 ELEVATIONS E-I FLR9�OR $11. ;'4 R15ER DP DESIGN PRESSURE HVHZ HIGH VELOCITY HURRICANE ZONE PET. POCKET WG WATER CLOSET BUILDING DESIGN AS ENCLOSED A-5 SECTIONS d ROOF PLAN IDE DR. DOOR INS. INSULATION PLYWD. PLYWOOD M. WOOD INTERNAL PRESSURE COEFFICIENT = t/- 0.18 UCIE C®t�„. DW DISH WASHER TNT. INTERIOR R.O. ROUGH OPENING � A-4 DETAILS PLUMBING � E.E. EACH END L6. LONG S.G. 50LID GORE EXPOSURE CATEGORY = G A-5 DETAILS ELEC. ELECTRICAL LIN. LINEN S.CD. SLIDING CLASS DOOR MEAN ROOF HEIGHT = 13 5" P-1 PLUMBING PLAN, ELEV. ELEVATION LT. .T LIGHT SF SQUARE FOOT FORT PIERCE DETAILS d RISERS E.S. EACH SIDE L.T. LAUNDRY TUB 5H SINGLE HUM& ROOF DEAD LOAD FOR WIND DESIGN TAKEN AT 10 p s.f. ST. L U C I E COUNTY FL NOTE. TH15 STRUCTURE 15 DESIGNED IN ACCORDANCE WITH CHAPTER 16 OF THE FLORIDA 1 BUILDING CODE AND A5GE 1-10. ELECTRICAL SYMBOLS LEGEND PLAN / ELEVATION A ION SYMBOLS LEGEND Q� DUPLEX RECEPTACLE/ ARC SINGLE RECEPTACLE ® LOW VOLTAGE FAULT INTERRUPT AT 12" A.F.F. DEDICATED TRANSFORMER SHEARWALL LABEL 1 Q� DUPLEX RECEPTACLE AT BASE SINGLE RECEPTACLE TELEVISION JACK FAN CARBON MONOXIDE DETAIL I I I I I I I I I IC30116ROUr FILLED CELL SEE ®% POTSHELF HEIGHT IIB DEDICATED 5WITCHED Q PREWIRED ® BOX ® DETECTOR CIO)—ALE SC4 p Z INTERIOR FOUNDATION PLAN //,(l/�///AS NOTED Q� DUPLEX RECEPTACLE AT �,'I� SINGLE RECEPTACLE HVAG JUNCTION SMOKE ELEVATION 5-# BEAM LABEL I� 8" ABV. COUNTER 0 DEDICATED UNDERGOUNTER Q THERMOSTAT ❑J BOX DETECTOR 3 POURED /�JJ���� PROPPED SOFFIT DUPLEX RECEPTACLE $ SWITCH INTERCOM PADDLE FAN H/ EXHAUST CONCRETE COLUMN [/l/ J HEIGHT AS NOTED Ter' GROUND FAULT INTERRUPT SINGLE POLE AT 60" A.F.F. OR WO/ LIGHT FAN # DETAIL 000# MAX. TRIJ55 CO�GTOR owc. SCALE DOOR LABEL TG_p LABEL �c DUPLEX RECEPTACLE AT 6" ABV. SWITCH SECURITY FLOURESCENT F L EXHAUST FAN NON -BEARING FRAME T- ARCHED OPENING SEE 6FI COUNTER GROUND FAULT INTERRUPT 1 s THREE HAY KEYPAD z LIGHT FIXTURE /LIGHT COMBO J CONSTRUCTION � L - PLAN OR ELEV. Q� DUPLEX RECEPTACLE SWITCH PUSH FLOURESGENT SPEAKER REVISION BEARING HOUR FIRE RATED II TOP REG. SWITCHED T4 FOUR HAY BOTTON LIGHT FIXTURE IN GL6. # SECTION FAULTDOOR CEILING MOUNTED 5 SCALE WINDOW LABEL CONSTRUCTION ® HALL QDWP DUPLEX RECEPTACLE WATERPROOF $ SWITCH n DOOR N GROUND FAULT INTERRUPT D DIMMER �' BELL LIGHT FIXTURE RELEASE NORTH ARROW - - - - - - FRAME CONSTRUCTION ^ DOOR WALL MOUNTED o VOLUME 2 HOUR FIRE DUPLEX RELEPAICLE 5WITGH !uc CHIME LIGHT FIXTURE CONTROL - - - - - - ABOVE OR BELOW ® RATED HALL � UNDER COUNTER K KEYED # SECTION QUADRUPLEX TELEPHONE OUTLET C. V. CENTRAL VACUUM SWITCH ° SCALE G# COLUMN LABEL RECEPTACLE ® AT 12" A.F.F. Y RECEPTACLE ® HI HAT DISCONNECT ^ LIB , BEAMBEA1E 16HT ® 4 HOUR FIRE TELEPHONE OUTLET DUPLEX RECEPTACLE SECURITY ® HIHAT ® BREAKER ELEV RATED WALL FLUSH IN FLOOR ® (� FLUSH IN FLOOR � LIGHTS VAPOR PROOF PANEL o z r e• ® 220 V. RECEPTACLE DEDICATED LED 0 REGE55ED g_� F.P.dL. METER d # INTERIOR ELEV. F# FOOTING LABEL �� GRAPHIC SCALE �O'-O" FIN. FL. SLAB FLOOR ELEVATION MASONRY CONSTRUCTION AT 12" A.F.F. ® DATA LINE ° L16HT EYEBALL DISC. 5CAL.E SCALE: 1/8.=1'-0• TYPICAL revisions no. date designed -- drawn LTH checked SBD date 06/01/20 (PERMIT SET) scale 1/4" = I'-O" (U.O.N) job no. 19062T_5F-21.Ih Scott Blakeslee Disher AR-0011586 AA-0003285 W O G Q 0 _ W O J LLj J W U. Q,z LU UJ W J W w_ 07 V f, a U) z 04 CV L0LL -0 project ARCHITECTel- Architecture Planning 300 Avenue of Champions Suite 260 Palm Beach Gardens, Florida 33418 Phone 561.202.6990 Fax 561.296.2494 archstudiofl.com drawing COVER SHEET revisions no. date (1) BLD6. DEFT. COMMENTS Oq/21/20 iv CALCULATIONS AIR CONDITIONED AREAS PLAN 1694 SF 1694 SF NON CONDITIONED AREAS PORCH 42 SF GARAGE 419 SF LANAI 109 SF 570 SF GROSS AREA GROSS AREA 2264 SF re WINDOW SCHEDULE MARK TYPE STYLE SIZE D.P. NOTES W H + - 001 SH26 SINGLE HUNG 3'-1" 6'-4" 40.40 43.92 002 PICTURE 24 PICTURE T-1" 4'-2 3/4-1 41.50 45.011 OPAQUE 003 PICTURE 24 ICTURE 3'-111 4'-2 3/4" 41.50 45.01 1 OPAQUE 004 PICTURE OICTURE T-0" 2'-0" 41.5 45.01 005 SH25 SINGLE HUNG T-0" 5'-0" 40.40 43.92 EGRESS 006 SH25 SINGLE HUNG T-0" 5'-0" 40.40 43.92 EGRESS 007 SH25 SINGLE HUNG T-1" 5'-3" 40.40 43.92 008 SH25 SINGLE HUNG 3'-10, 5'-3" 40.40 1 43.92 009 SH25 SINGLE HUNG '-1" 5'-3" 40.40 43.92 010 SH25 SIN LE HUNG '-111 !3'-l 5'-3" 40.40 43.92 011 SH25 SINGLE HUNG 'r 5'-3" 40.40 43.92 EGRESS DOOR SCHEDULE MARK STYLE DOOR D.P. NOTES WD HGT + - 001 SINGLE EXTERIOR T-0" 8'-0" 39.02 42.54 NOTE #5 002 SINGLE 2'-8" 8'-01' 003 SLIDING DOUBLE 5'-0" 8'-0" 004 SINGLE 2'-8" 8'-01, 005 SINGLE 2'-811 8'-0" 006 SINGLE 2'-8" V-011 007 SINGLE 2'-81' 8'-0" 008 SINGLE 2'-61' V-011 009 SINGLE 2'-6" 8'-0" 010 BIFOLD 1'-6" 8'-011 011 SLIDING DOUBLE EXTERIOR 6'-0" 8'-0" 37.15 40.67 012 SINGLE 2'-0-1 81-0" 013 SINGLE 2'-611 8'-011 014 SINGLE 2'-8" 8'-0" 015 BIFOLD 21-411 8'-0" 016 SINGLE 2'-4" 8'-0" LOUVERED 017 SINGLE 2'-8" 8'-01, NOTE #2 018 OVER EA 16-0" T-0" 1 35.03 42.00 NOTES: I. ALL WINDOW 4 DOOR (5LAZI% To BE LOW-E: NON IMPACT - (IMPACT OPTIONAL) 2. 6ARACE ENTRY DOOR SHALL BE SOLID WOOD DOOR NOT LESS THAT 1-5/5" IN THIGKNE55, SOILID OR HONEYCOMB -GORE STEEL DOOR NOT LE55 THAN I-3/8" THICK OR 20 MIN. FIRE FATED DOOR, EQUIPPED WITH 5ELF- CL051N6 DEVICE. PER FBC-R302.5.1 3. VERIFY ALL OPENING PRIOR TO MANUFACTURIN6 WINDOW 4 DOORS. 4. ALL EXTERIOR WALL OPENIN65 IN BUILDIN66 (DOOR5, WINDOWS) WILL BE FULLY PROTECTED WITH IMPACT 5. D R WITH 1 Y OF FB. 201 . Product Opening Design Pressures Product Rated Design Pressure Manufacturer Model Number Prod Approval ber Glass Type Method of Attachment Windows 55.0 65.0 CGI SH-4100A F 3358.2 Lami Flange Frame Mullions 90.0 90.0 CGI Series Clipped - 18-13129.08 Fixed Glass $5.0 65.0. - CGI Pw-4120A F 6095.2 Lami Flange Frame Block Glass Skylights Sliding Glass Doors 55.0 65.0 CGI SGD-4130A F 9078.2 Lami Flange Frame Swing Type Doors 50.0 50.0 Therma-Tru Smooth Star F U 0468.6 Lami French Doors Garage Doors Hurricane Protection Roof Ventilation N/A N/A O'Hagin Cloaked Vent 19 109.02 Roofing Material N/A N/A GAF Asphalt shin L10 24-R27 Fasteners Revised 07/22/2014 I have reviewed the above components or cladding and I have approved their use in his structure. These products Drovide adequate resistance to the wind loads and forces specified by current code provisions. ..F..,, Digitally signed by Scott " Blakeslee Disher Scott Disher a "' DN:cn=Scott Blakeslee Name: Signature: Disher, OSS Architect AR 11586 9/17/20 email=sdisher@archstudiofl.c Design Prof: Cert. No. Date: _ ome:2 Date: 202020.09.7811:31:43 -04'00' i i A A3 1HB W'I ra `r - ---------- �- 1 DINING LANAI 011 q'-4" GL6. q' 4' GL6. W-10" I m 5 6 a, in - 121s" 006 2l'-O"JVVINERS SUITE - c T-4' GLe. FAMILY 10 ROOM 4' 201-0" W-4' GL6. Fq ISLAND I COWER o 07 61 " m irk' p 36" A.F.P. I I i DW i DEL. SINK ;1 KIDISP05AL IS' b" WH/ MICRO HEN• " 21 ATll 5- --1 V-4/ [4:\ .1 012 " 41-4" ONE N S TH O CL6 Aev --- 0-� ---`t ry PANTRY 5 5". I 1 IR-15 r--- WIC 111-4" 015 �t BEDR W-4" OM 3 O oo$ m 010 " 2" �_-_� i 11 O _ WIC 22W' l I �"_LT J IR-15 I I Q LINEN - 5 SM/S. IGALLERYI I W-4" to 101-0' 1 DOFF. GL6. 013 _ 1 ( 4,-8. 014 r 110'-2" w r " 1 4'-10" L--- I 1 016 1 017 m EWH O OU BA GHL62 005 LA NIDFtr=t GL6: 004 I' b" 4'-8" 2'-6" Ig' 4'-10" is 22k36 PANEL 'A' BUILD OUT METER 4 DISC DR1'Ei2 - I I FOYER 1'-4" ('Le.ii L)Lpc. LT.i ON A-4 m IR-IS 4 - - - - - rr - 002 51-4" E65ZE55 DOOR INSULATE W6LL5 W/ R-II MIN. BATTS (TYP) 2 CAR GARAGE 1 C4 t 003 15-10" BEDROOM 2 q1IN CL.6. _ _ _ _ LINE OF GARAGE DOOR ABOVE d1 001 I PROVIDE 6ARA6E VENTILATION PER FMG T 1 VENT IN 6ARA&E DOOR VENTILATION MEETS 3.1.1 THE 1 i REQUIRED VENTS ALONG 6ARAC-E DOOR FE ZIMETER. P R CH I I r 1 I 1 I i I Q p q 1 = designed drawn LTH checked SEE) date Ob/01/20_PERMIT r scale 1/4" = 1'-0' (U.o.N) jot) no. I110b27-5Fmm219t Digitally signed by gar<�orrrO�o eq : Scott Blakeslee Disher �:. A A DN: cn=Scott g'' • Via` `REDA0. Blakeslee Disher, o, ou, ��. G4"xwu"e�mmPun"aJM« email=sdisher@archs tudiofl.com, c=US �- -"'� Date: 2020.09.21 15:02:34-04'00' Scott Blakeslee Disher AR-0011586 AA-0003285 LLI U W W LU 0 J < Q w Z ® U LU nJ ( EL �- H v Z Q CV U) N W to ® -0 project R ARCHITECT AL ui✓V V(! � y�/V o EVIEWED FOR 3E 1 "'ra IANC LU IE Oyv g 014 Architecture Planning 300 Avenue of Champions Suite 260 FILE COR4 Palm Beach Gardens, Florida 33418 Phone 561.202.6990 Fax 561.296.2494 archstudiofl.com drawing FLOOR PLAN sheet A-1 revisions no. date 'I 1 : 5TUCG0 COVERED FOAM BRACK Li 4 PROFILE ELEVATION BRACKET DETAIL SCALE: I"= 1'-0" FAUX COLUMN WRAP. STEEL COLUMN 5DR 5TRJ4TURAL 2 MOULDING DETAIL SCALE: 1 1/2" = I'-0" a COLUMN WRAP 5GALE: 5/4• = I'-0" eSTONE VENEER @CMU SCALE: N.T.5. 60• HIGH 4 111 PRIVACY WALL AA -AA A3 designed --- 12 drawn LTH ARCHITECTURAL ASPHALT checked SEC ROOFING 5HIN6LE5 date 06/01/20 (PERMIT SET) scale 1/4" = 1'-0" (U.O.N) job no. IgO6Z7_SF-21.Ih u TEXTURED CEMENTITIOU5 COATIN6 OVER GONGRETE BLOCK LEFT ELEVATION _ 0'-0" FIN. FL. SLABB Scott Blakeslee Disher AR-0011586 AA-0003285 W 0 z W 12 vJ Q4 W ARGHTECTURAL ASPHALT ROOFING 5HIN6LE5 J W 0 TEXTURED GEMECOW,US COATING OVER GONG. ` r Q APPLIED BLOCK Q DECORATIVE � O �— STONE PRIVACY WALL _ BEYOND > J F- ILL. LU N LL ¢ W O O'-O" FIN. FL W 0 V -- -- -- -- -- — - -- -- - JU' o W F- RIGHT ELEVATION z N U) LO� project REVIEWED FOR CODE COMPLIANCE AR HITECT RAL ST. LUCIE COUNTY l .. _ BOCC �' , �G• A A Architecture A3 t Planning 1 A2 Ixb RAISED Q I STUGOO BANDING FILE CV t#Y 12 FAUX SIDING W/RAISED Ix2 300 Avenue of Champions Q4 ARGHITEGTURAL ASPHALT ' �4 STUCCO BANDS Suite 160 ROOFING SHINGLES I ARCHITECTURAL ASPHALT Palm Beach Gardens, Florida 33418 ROOFING SHIN6LE5 Phone 561.202.6990 Fax 561.296.2494 q'-4" T.oeB. �• _ g'-4" r.oBB. azchstudiofl.com I�_4�� TEXTURED GEMENTITIOUS IL O.H. O.H.W/ 4' SURROUND ■ BOATING OVER GONG. I drawin BLOCK —COACH LIGHT z g I I Ii4�l ELEVATIONS O II I I_ 8"WIDE, 60" HIGH PRIVACY WALL. 6"5TUCC0 HEAD W/ 4" SURROUND — In = i n _ O'-0" FIN. FL. SLAB 0'-0` FIN. FL. SLAB 1 REAR ELEVATION FRONT ELEVATION Sheet A-2 revisions no. (U BLD6. DEPT. COMMENTS date OF/21/20 E FLAME SPREAD & SMOKE DEVELOPED INDEX R3029.1 FLAME SPREAD INDEX: WALL AND GEILIN6 FINISHES SHALL HAVE A FLAME SPREAD INDEX OF NOT GREATER THAN 200. EXCEPTION: FLAME SPREAD INDEX REQUIREMENTS FOR FINISHES SHALL NOT APPLY TO TRIM DEFINED AS PICTURE MOLDS, CHAIR RAILS, BASEBOARDS AND HANDRAILS; TO DOORS AND WINDOWS OR THEIR FRAMES; OR TO MATERIALS THAT ARE LESS T14AN 1/25 INCH (OAI MMU IN THICKNESS CEMENTED TO THE SURFACE OF WALLS OR CEILIN65 IF THESE MATERIALS EXHIBIT FLAME SPREAD INDEX VALUES NOT 61REATER THAN THOSE OF PAPER OF THIS THICKNESS CEMENTED TO A NONCOMBUSTIBLE BACKING. R302.92 SMOKE -DEVELOPED INDEX: WALL AND GEILIN6 FIN15FE-5 SHALL HAVE A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450. R502A.3 TE5TiN6: TESTS SHALL BE MADE IN ACCORDANCE WITH ASTM E54 OR UL 125. 1 GABLE END WALL VAPOR RETARDER NOTE: APPLY CLA-% II VAPOR RETARDER (0.1 < PERM s I.0 PERM)— KRAFT-FACED FIBER&LAS5 BATT5 FOR ZONE 11 PER FBC-RTO2.1 4" RA15ED ARCHITECTFURAL ASPHALT SHINOLE5 ON 30# FELT HOT MOPPED OVER 15# FELT TIN TA66ED TO 19/32" (5/50) EXT. GRADE PLYM. SHEATHING. PRE-EN6. WOOD ROOF TRU55'5 @24' 12 0/0 TYPICAL W/APPROVED GALV. TRUSS ANCHORS EA. END 4 SEE PLAN. 6ALV. MTL. DRIP ON P.T. IX2 CONT. 2X5 FASCIA 2-16d 6M TOE NAIL a EA.TRU55 / 1"x24" SOFFIT VENT / (SEE ROOF FLAW '-4- O.H. CEMENTITIOUS COATIN6 OVER HI -RIB P.B. 6ALV MTL LATE SECURED TO TRUSSES. 5/5" CEMENTITIOU5 FINISH OVER 5" GONG. BLOCK _ 1 VERTICAL STEEL IN 6ROUTED CELL SEE PLAN. I Y2" BLOCK RECE55 0'-0" T.O.5LAO —' I r I rI1 a z —III III —II _!" 4 — 11=1TI=1 a-- — I I r R-30, BLOWN INSULATION - SEE ENERGY GALLS. H16H 5TREN6TH / RI61D CL6. ORD. APPLIED TO UNDERSIDE OF TRU55'S FIRE STOP CONT. 5"x5" MASONRY BOND BEAM SEE STRUCTURAL OH55. CONT. METAL POUR STOP 1/2" DRYWALL IX2 P.T. FURRING ® 24" 0/6 IN/ INSUL.. SEE ENERGY GALL. - TYPICAL I"x4" WOOD NAILER APPLIED WOOD BASE FIN. FLOOR TO BE 15" MIN. ABOVE GROHN OF ROAD MIN. MONO. GONG. FOOTING SEE FOUNDATION PLAN FOR NOTES # DETAILS TYPICAL WALL SECTION SCALE 5/4' = 1'-0' CRAFTSMAN - ELEVATION r' EXTERIOR GEILIN6 NOTE: CEMENTITIOU5 SOFFIT OVER HI -RIB 6ALV. METAL LATHE TO COMPLY W/ FBG-R 105.4 AT COVERED ENTRY AND COVERED LANAI (TYPE ® 1 I OPEN j I I PORCH FOYER I I I I I PRE-EN6INEERED HD. ROOF E-- TRUSSES ® 24" O/C TYPICAL --� GALLERY 1"x24" SOFFIT 1'-4 OVE OWNERS SUITE ROOF PLAN SCALE: 1 /8" =1'-0" ATTIC VENTILATION REQUIREMENTS THE RATIO OF TOTAL NET FREE VENTILATION AREA TO THE AREA OF ATTIC GEILIN6 SHOULD NOT BE LESS THAN 1:150 ROOF VENTILATION CALCULATION: VENTILATION AREA REQUIRED FOR ATTIC ATTIC AREA = 2264/150 = 15.011 50.FT. OF VENT OR 2,113.44 5Q.IN. VENTILATION AREA PROVIDED FOR ATTIC: SOFFIT VENT = 2,115.44 50.IN. SOFFIT VENT = 1"X24" = 126 SQ IN NFA - N VENT5 PROVIDED 12 4 FIN LANAI FILE COPY ARCHITECTURAL ASPHALT ROOFING SHIN6LE5. II'-0" T.O.B.B. T.O. 2ND FLOOR 9'-4" T.O.B.B. -- EXTERIOR GEILIN6 NOTE: O.H. CEMENTITIOUS SOFFIT OVER HI -RIB 6ALV. METAL LATHE TO COMPLY W/ FBG-R 103.4 AT COVERED ENTRY AND COVERED LANAI (TYP). 0'-0" FIN. FL. SLAB designed -- drawn LTH checked Sw date 06/01/20-PERMIT scale 1/4" = 1'-0" (UO.N) job no. 1,10621_517mm.21st Digitally signed by �EOF FIOR Scott Blakeslee Disher A: AR 15M :w DN:cn=Scott Blakeslee Disher, o, RED Ark' Ou, email=sdisher@arc hstudiofi.com, c=US na.�...rcree.� vmen,an. Date: 2020.09.21 15:02:53-04'00' Scott Blakeslee Disher AR-0011586 AA-0003285 W U Z W 0 ! VJ W�// I..L— J a w � O J ¢ J FL UJ U. Z U W W —J w_ U) (D p �' U) Z N N V) LO O .Q project ARCHITECTURAL 5�4d�o 0, ?Oevo* Architecture Planning 300 Avenue of Champions Suite 260 Palm Beach Gardens, Florida 33418 Phone 561.202.6990 Fax 561.296.2494 archstudio0.com drawing SECTIONS & ROOF PLAN A -A SECTION A.A. A-3 sheet A-3 5 5/V MTL. STUDS + DW FINISH PREFAB ROOF OR FLOOR WOOD FRAME WALL TRU55E5 / / MTL WALL STUD TRACK TO ?/8" GEMENTITIOUS FINISH / ROOF OR FLOOR TRUSSES F ROBEHOOK MEDICINE CABINET Y2-' GYPSUM WALLBOARD 15o FELT W/ METAL LATH - LAP ATTACHED TO WALL STUDS OF TOWEL BAR 5HOWER NICHE LATH OVER WEEP SCREED PER F.B.C.R. 4" 4" 3 5/a' OR 6" X 25 GA TO OF SOAP D15H AT WEL RING HOU5EWRAP ON 5HEATHING - LAP GALVANIZED NON -BEARING 5HOWER OVER SELF -ADHERED FLA5HING METAL WALL STUDS AT 24" AND TAPE O.G. MAX. 50RENED TO TOP 4 BOTTOM WALL TRACK Not TOILET PAPER HOLDER Q PANHEAD SCREWS OF SOAP V15H AT LOCATE ON FRAMED WALL LL Q SELF ADHERING FLEXIBLE GALV METAL BASE TRACK FASTENED 5TANDARD TUB m v o LL 4 LL in FLA5HIN6 OVER WOOD WALL TO CONCRETE FLOOR W/ PONIER ACTUATEDEl < a ¢ Q AND CMU JOINT, EXTEND 5" MIN. ELECTRICAL PINS AT 24" O.G. a — DOWN FROM JOINT OUTLET 0 q LC v � LL BASE MOLDING NQ n ,e 6Q Q O H 17 MASONRY WALL ry as -1/5"CEMENTITIOU5 FINISH FINISH FLOOR FINISHED FLOOR ELECTRICAL PANEL BOX WALL SECTION - INTERIOR BATH ACCESSORIES MTNG. HEIGHT GABLE-CMU JOINT SCALE: 314'=1'-0" SCALE: 3I4"=1'-0' SCALE: 1l2'=1'-0° SCALE: 3"=1'4" MAS. WALt� TL. STUD WALL DRYER VENT GEMENTTIOUS FIN15H _ FOR MASONRY WALLS: ' 1X4 CONTINUOL15 P.T. CABINET . BLOCKING AT MA50NRY WALL5 - TOP AND BOTTOM OF UPPER CABINETS AND AT TOP OF LOWER CABINETS ,.,... BACKER BOARD D 4" DEEP RECE55 W/ 1/2" • • J PRIDE GAP OFF SLOPED p p PLYWOOD BACKING WITHIN — MORTAR BED. (oil WLL A. D p D s f O AT MTL. STUD OR FRAME WALL5: `' SLOPED MORTAR BED z IL 9 µZµI f 2x CABINET BLOCKING BETWEEN • • {• • Ul W 5TUD5 - FULL WIDTH OF CABINET - ° TILE TOP AND BOTTOM OF UPPER CABINETS AND AT TOP OF LOWER ":. .' D , DDp D p D C'RADE z v CABINETS cl P D Q W n P D D n p D: °° D D N Ul I °. •,D p D e p DD p pD D -° D G /\\\/\\\/\ \/ •••�.. P'. eC D D pD D e ° FIN15HE12 SLAB .:...:. DRYER VENT DETAIL CABINET BLOCKING DETAIL SHOWER RECESS AT SLAB FOUNDATION SILL SCREED-CMU SCALE: 314"=1'-0" SCALE: 314"=1'-0" SCALE: 3"=1'-0" COD .. CODE ST. LUL6i 5.. 1/2" GYPSUM WALLBOARD Y :s VA 5.1 5Q FT AREA CLEAR OPENIN5 r (EXEPTION: GRADE FLOOR 5.0 50.FT) W J U / \ fo TO FRAME OPENING MTL FRAME PARTITION O WALL SET TO ALIGN : • : ` GYPSUM BOARD. 20„ W MIN. OPEN GI-;= X Wff (L Q a� O� Z INSULATION (SEE ENERGY FINISHED FLOOR = CALCULATIONS) v SECONDARY MEANS OF ESCAPE MINIMUM WINDOW CLEAR OPENING GMU WALL REQUIREMENT. (SEE STRUCTURAL DWGS) IX P.T. FURRIN6 EGRESS REQUIREMENT DETAIL WALL ALIGNMENT DETAIL SCALE: 1r2"=1'-0" SCALE: 3"=1'-0" revisions no. date designed -- drawn LTH checked 513D date 06/01/20 (PERMIT SET) scale 1/4" = 1'-0" (U.O.N) jolt no. I10621_5F-21.Ih Scott Blakeslee Disher AR-0011586 M-0003285 U z 0 W L.J.. 0 O G U C C LLj � O J L.L. Q "J l� . U Z U LILI L fJn -i Ly _w d rn V z Q N U) 04 FJ) LO � project r ARCH ITE CT RAL TiG 4'liG. Architecture Planning 300 Avenue of Champions Suite 260 Palm Beach Gardens, Florida 33418 Phone 561.202.6990 Fax 561.296.2494 archstudio0.com drawing DETAILS sheet A-4 CONCRETE V-RIDGE SEE MANUR DATA AND PRODUCT 26 GA. HOT DIPPED 6ALV. APPROVALS FOR ATTACHMENTS. MTL. RIDGE AND HIP TILE MASONRY LINTEL OR SUPPORT OVER ROOF 2x P.T. BUCK ATTACHED TO COLUMN N CONCRETE LINTEL OR GONG. BEAM (SEE 5TRUGT — I/4" MIN GAP BETWEEN MEMBRANE 5/5'x5" WEDGE BOLT ONG. SCREWS® MASONRY JAMB D W° PLYWOOD AND LINTEL/BM. 2'-0" 0/0 4 3 1/2" MIN EMBED. VERT. (b" FURRING ° M ENDS) W/ 2"X2"XI/4" STL. FA5TENER5 51ZED ANDSPACED ,, D D REFER TO "WOOD FRAME -DOWN HASHES a a PRODUCT p POHN FROM MASONRY p ° ° D FLASHIFl6" DETAIL FOR I x P. T. NAILER APPROVAL LINTEL (SEE STRU TaFRAME ° ° TRANSITION FROM MASONRY TO MORTAR SETTING GARAGE DOOR ASSEMBLY. a WOOD FLASHING = GEMENTITIOU5 FINISH - REFER GYP. BD. TO ELEVATIONS FOR HEAD FASTENERS SIZED AND SPACED a AND JAMB TRIM VARIATIONS INSULATION PER ENERGY GALL. PER PRODUCT APPROVAL a4 a WOOD GASING p WATERPROOFING COATING Ix P.T. WOOD BUCK - MIN. CEMENTITIOUS FINISH ON 15# EXTEND ALL AROUND AND WIDTH TO MATCH WIND. FRAME FELT W/ LATH ON HOU5E1ARAP CONTINUING 6" AT FACE ON EXT. GRADE SHEATHING OF CMU WALL ° WOOD/PLASTIC DOOR STOP p p ° c D W/ INTEGRAL WEATHER STRIP. D ° D SEALANT PVC CORNER BEAD 1/2" GYPSUM WALLBOARD PVC, CORNER BEAD DRIP SLOPE ® HEAD —� SEALANT DRIP SLOPE AT HEAD 2 x 8 P.T. WOOD BUCK GEMENTITIOUS FINISH ON SEALANT ° ° SET IN URETHANE SEALANT GALV. METAL LATH SEALANT pD° D p e WATERPROOFING MEMBRANE ROOF MEMBRANE PER , D f COATIN6TO EXTEND ON TOP CONTINUOUS URETHANE SEALANT PRODUCT APPROVAL p °: AND EXTERIOR FACE OF BUCK5 BEAD BETWEEN FLANGE AND _. SEALANT BUCK FLAT/5-TILE SYSTEM CONRETE TILE WOOD FIBERGLASS DOOR SYSTEM INTALLED PER PRODUCT AND FRAME - ATTACH PER APPROVAL (FLAT TILE INDICATED) PVC, CORNER BEAD PRODUCT APPROVAL PLYWD. SHEATHING. GEMENTITIOU5 FINISH. NOTE: REFER TO "FIN WINDOW FLA61-1I146 I50" ALUM. 51NOLE HUNG WINDOW - MASONRY WALL DETAIL FOR HOU5E-WRAP AND SELF ADHERED ATTACH PER PRODUCT APPROVAL FLEXIBLE FLASHING INSTALLATION IN CONJUNCTION WITH THI5 DETAIL ROOF TO CMU WALL -FLAT OR S-TILE GARAGE DOOR JAMB-CMU OUT SWING ENTRY DOOR HEAD/JAMB-CMU WINDOW HEAD -FRAME DOWN SCALE: 3'=1'-0" SCALE: 3'=1'-0" SCALE: 3'=1'-0" SCALE: 3'=1'-0" PAVERS ON SAND BASE ROOF CEMENT ALL SIDES GARAGE DOOR CONCRETE LAMB OR ONE PIECE SLEEVE FLASHING LAP MEMBRANE BASE SHEET LAP 2" INSIDE VENT. AND GAP SHEET OVER TOP OF I x P.T. WOOD BUCK -MIN. WIDTH TO FLANGE ABOVE VENT PIPE TO WOOD OR FIBERGLASS DOOR MATCH WIND. FRAME - SET IN 3" PAST VENT PIPE SET THRESHOLD URETHANE AND FRAME - ATTACH PER URETHANE SEALANT BED. FASTENERS SIZED AND SEALANT 4 SLAB PRODUCT APPROVAL SPACED PER PRODUCT MEMBRANE BASE SHEET WATERPROOFING COATING 4 APPROVAL AND GAP SHEET UNDER GONG. SLABHATERPR a TOP OF FLANGE BELOW FURRING COATING APPLIED VENT PIPE SEALANT 4 AROUND GhRJ OPENING 6" ON FACE OF CMU WALL APPLY CAULKING TO FLOOR LEVEL x P. T. NAILER a CEMENTITIOU5 FIN15H - z y I'-0° REFER TO ELEVATIONS SEALANT a FOR HEAD AND JAMB APPROVED ROOF Q FLOOR FIN. TRIM VARIA71ON5 TILE SYSTEM ��' SLOPE SEAL P.T.W000P BUCK 11 GEMENTITIOU5 FINISH" GYPSUM BOARD IW AT JOINT AITH on w ' D° T CORNEER TRIM PVC, CORNER BEALLER D b N J ° " '" DRIP SLOPE 0 HEAD of , SEALANT FIN FLOOR SEALANT D . °D p. D ° ° ° D D ° ° D D CONC. SLAB ° ° WATERPROOF MEMBRANE PLYWOOD ROOF p b B D 6 °, ° COATING APPLIED TO r� SHEATHING D > , ° D > p D ° p a p ° e ° TOP EXTERIOR p , D D ° D p D FACE OF BUCKS ° D D CONTINUOUS URETHENE ° p " j° ° D , S p °D ° op ° SEALANT BEAD BETWEEN VENT PIPE THROUGH P ° ° a ° D FLANGE AND BUCK ROOF. AV ° p FASTENERS 51ZED AND SPACED PER PRODUCT , WINDOW, INSTALL PER o APPROVAL NOTE: REFER TO "GMU OPENING PRODUCT APPROVALS WATERPROOFING" DETAIL FOR ADDITIONAL WATERPROOFIN6 VENT-THRU-ROOF DET. FLAT OR S-TILE GARAGE DOOR SILL -PAVER RECESS UTILITY SWING DOOR SILL SCALEt FLANGE WINDOW HEAD/JAMB-CMU SCALE: 3"=,'-0" SALE: 3'=1'4' a'=,'-0' smREM9 WED FOR CODE COMPLIANCE ST. LU IE COUNTY NO SILL FASTENERS - VERIFY OCC WITH PRODUCT APPROVAL 6" WOOD OR FIBERGLASS DOOR WINDOW - INSTALL PER AND FRAME- ATTACH PER SEALAN PRODUCT APPROVAL PRODUCT APPROVAL IX2 PT FURRING AND I/2° EXTERIOR MN DRYWALL OVER 5" WALL. 5TUO0 OVER 5" WALL STOOL PER SPEC �IHOOP TR1155E5 HATERPROOHNS, INSULATION, SEE NINDOH SILL, E'., •iJAM55 AND WAD, SET P.T. kOOD BXK OVER APPLY AROUND �,�• ••CMU KATIERPROOFIN& IN CORNER AND PER PRODUCT APPROVALS. AROUND THE FACE OF THE KALL. INSULATION ENERGY CALO 22" MIN. W. X 56" MIN. D. (ROUGH -FRAMED) SEE 51ZE ON FLOOR PLAN BOARD INEROY i0 o oFLOOR Q o m SET HIGH VELOCITY THRESHOLD 5EALANT CONTINUOUS URETHANE IN URETHANE SEALANT 4 SLAB WATERPROOFING COATING SEALANT BEAD BETWEEN COP' FILE COP' FLANGE BLOCK V r SEALANT I x P. T. NAILER SEALANT FIN. SEAL WINDOW TO BLOCK 4 OPE SLOPE TO DRAIN STEPPED POURED OR , _ PRECAST CONCRETE SILL miv —all'i- 1/2" GYPSUM WALLBOARD L1 ° WATERPROOFING COATING, D D-m o D o APPLY ON SILL, EXTEND b" ° °< MASONRY WALL a DOWN THE WALL. ° D D a ° FASTENERS 51ZED AND 54ACED FURRING PER PRODUCT APPRQVAL ; D ° D- GEMENTITIOUS FIN15H SEE p ° <A ELEVATIONS FOR SILL TRIM MEMBRANE OVER THE TOP AND VARIATIONS. OF P.T. WOOD EXTERIOR FACE OF BUCK AND SILL. 1/2" GYP BID. TWEATHERSTRIP ° - - - ° - SUCK TO MASONRY CONC. SLAB D NJMEER5 REPRESENT PAVERS ON COMPACTED INSTALLATION SEQUENCE ATTIC ACCESS PANEL p ° SAND BASE NOTE: REFER TO "CMU OPENING 0 D D p D WATERPROOFING" DETAIL FOR 51ZE PER PLAN PANEL, HINGED WITH ADDITIONAL WATERPROOFING INSTALL WINDOW OR DOOR, FASTEN PER PRODUCT LATCH; 1/2" GYPSUM BOARD ON 50' APPROVAL AND SEAL WINDOW OR DOOR FRAME TO PLYWOOD FASTENED WITH DRYWALL - P.T. WOOD BUCK AND MASONRY SGREW5 ® 6" O.G. PERIMETER 4 12" O.G. CMU OPNG WATERPROOFING -ISO ATTIC ACCESS DETAIL FRONT SWING DOORSILL- PAVER RECESS FLANGE WINDOW SILL-CMU SCALE: 3'=1'-0" SCALE[ 3"=1'-0" SCALE: 3'=1'-0" SCALE: revisions no. designed drawn checked date scale job no. date LTH 5BD 06/01/20 (PERMIT SET) 1/4" = 1'-0" (U.O.N) 190621_SF-21.Ih Scott Blakeslee Disher AR-0011586 M-0003285 W U Z W 0 '' VJ 1..1— 0 O G J G LL fJn V ''Z VJ project � U J Q J U_ W Z U W of (J) I j w �- F— p Cn CV CV O >+ LO LL -0 ARCHITECTRA L%W40 1111, Architecture Planning 300 Avenue of champions Suite 160 Palm Beach Gardens, Florida 33418 Phone 561.202.6990 Fax 561.296.2494 archstudio0.com drawing DETAILS sheet A-5 revisions no. date COLUMN SCHEDULE MARK 51ZE TYPE DESCRIPTION G-1 bx8 BLOCK GONG. BLK. W/1 FULLY 6ROUTED CELL W 45 VERT. EA. CELL o 6'-0" O/C MAX. OR A5 LOCATED ON PLANS G-2 8x16 BLOCK CONC. BLOCK W/2 FULLY 6ROUTED CELLS W/1-15 VERT. EA. CELL C-3 12x/2 BLOCK GONG."O" ELK. FULLY &ROUTED W/4415 VERT. •2 TIES o b" T.O. IN MORTAR JOINT 0-4 6xl2 BLOCK RINKER T324 OR EQUAL CONG. "O" ELK. FULLY 6ROUTEO k0-05 VERT. G-5 3-1/24x3-1/2"xl/4" TUBE STEEL PROVIDE STEEL GAP PLATE AND SADDLE A5 NOTED ON DETAILS BASE PLATE 4"x4"x5/8" W/ (4) 5/8' DIA. WEVOE ANCHORS W/ 4' MIN. EMBED. i I f I I 1 I I i i FOOTING SCHEDULE MARK SIZE (kW) REINFORCING DESCRIPTION DETAIL NO. F-I 16"xl64xCONT. W/2 d5 CONT. - 2 TOP d 2 BTM. W/ DOUBLE LAYER OF MESH, 49' WIDE EXTERIOR MONOLITHIC ONE 5TORY 1 F-2 16'xlb'xCONT. W3 +5 CONT. - I TOP $ 2 BTM W/ DOUBLE LAYER OF MESH, 46" WIDE EXTERIOR MONOLITHIC AT SHOWER d 6ARAOE RECESS 3 F-3 4'-O" x 4'-0" x 14' W415 EA BTM 1501ATM PAD 7C TE-1 IO' x DROP x CONT. WAS CONT. THICKENED � m&E 34 STILGO 1 GOLtk115TP. HOOKS 48 IA. FINISH 1 WELDED WIRE MESH, SEE SCHEDULE N w TOP BENT BARS A5 IO TRANSVERSE REBAR APPROX. &BADE -1 20m OAZI 11Wx sv. z p y < x E I (5) 85 GONT. TOP ap d BTM. PVI #4 j; I TRANS. A5 NOTED I TOP TYPICAL o _ FOOTING REBAR 5CHED. SEE POOTINO SGHED. �L—_ �_—__� OMIT CENTER BAR 1If I WHEN ONLY (2) REQD. 2' e, EXT. CONT. MONOLITHIC (U b' MATGHIN6 DOWELS F GONT. AT COLUMNS 48 BAR DI, A EXTERIOR FOOTING MID. OF MIN. W/STD. HOOKS WELDED WIRE MESH, S 1 J �� f SEE SCHEDULE u GONG. TOP BENT SAR5 A5 FILLED 0 KNOCKOUT s REO'D, SEE 56HED BLOCK WA u5 GONT Frr-TRAN5VERSE REBAR -r' STUCCO FINISH z f :o (1) #5 VERT. IN p FILLED CELL o 52" - I. O/G TYPICAL Jai FOOTING REBAR x5 DOPE-5 0 48" SEE FOOTING SGHED. O/G W/MIN 48 BAR 5GHED. OMIT CENTER BAR DIA. LAP, TYPICAL 3 WHEN ONLY (2) REQD. EXT. CONT. MONOLITHIC APFROX. 6RADE GOAT COL. W/ MASTIC d COVER 5) M5 GONT. TOP I Fo1r, W/BUILDIN6 PAPER BTM. W/I #4 STEEL COLUMN TRANS. AT 16' :vFi IN6 TOP TYPICAL Wi5 I I ANCHOR BOLTS d BASE PLATE SEE &ROUT BED III COL. SCHEDULE PRIVACY WALL DETAIL VlfkVSW. MASONRY COLUMWIMATCHING DOWELS 46 BAR DIA. MIN. CRAVE HOOKS _ II ry z r AD REBAR EQ. EQ. SEE FOOTING SCHEDULE ED61 SEE SSHED. BAR5 ALWAYS REMAIN. SPACE OOTHERS �C ISOLATED PAD EQUALLY W 145 CONT. 3" MIN. COVER 0" 34 THICKENED EDGE #1 I I (4) •5 DOWELS I/4I EXP. I I W/ STD. HOOKS JOINT DECK OR 1T3 I E5 0 12" 51A8 00/G VERT. GONG. PIER OR SIZE u PAD REBAR SEE FOOTING —44 5CFEDULE; EDGE BARS EQ. EQ. ALWAYS REMAIN. 5PAr: OTHERS 5EE SCHEDULE EQUALLY 42 PAD AT EXT. STEEL COL. C i� 12'-4" F -1 designed -- drawn LTH checked SEP date 06/01/20 (PERMIT SET) scale 1/4" = I'-O' (U.O.N) job no. 140621_5F-2I.111 l G2 G2 „_ I —------- FI �o ----- i �PAVERS-\ SEE s DETAIL t S1 `gyp I 13 I I I I mm_ 2 I I ---------- I FI 4 I r I I I I FI I I I I - I I I — I I I �-1 F2 I FLOOR SLAB TO BE 4" THICK POURED CONCRETE n SLAB WITH b" X b" X WIAXWIA W.W.M. ON 6 MIL p VISQUEEN (OR EQUAL) ON GLEAN HELL COMPACTED 6: FILL. W.W.M. SHALL BE LOCATED IN THE MIDDLE TO I \ I UPPER HALF OF THE SLAB DEPTH AND MUST BE I SUPPORTED AT 3'-0" O/G EACH WAY WITH APPROVED MATERIALS. _J I C 1 0'-0" FIN. FLOOR SLAB i- I o I I I I I TE-1 IF TO — r------Ey $ _ 2'-8"I C! E I O 3'-0" X2-I/4" Q 6ALV. I PIPE W/ THREADED STL. END TO I • T L I I I ATTACH GAP. 5" DIA. (4) HOLES I POWERS OR TITAN FED BASE W/ IAV I " A5TENER5 I r Q I I SLEEVE WALL FOR I I WATER SERVICE, COORDINATE IN FIELD. 164" I 0141. I - - TYR I I F2 a N Q U.O.N. FI I I P W7 FI I �C I I I I I F2 I GI 4 G4 — — — — — — — J GI G3 GMU GOL W/TOP AT 3-0" A.F.F. NV03 STL. TUBE COL.TO UNVER51DE OF GONG. LINTEL. SEE BEAM SCHEDULE FOR SIZE. G5 sort G4 EXTEND MONOLITHIC F r,55)TOP FT(5.UNDER 05 (12" WIDE) 4'-T I'-&,. 4'-9" IEWED FOR COMPLIANCE )CIE � BOG Scott Blakeslee Disher AR-0011586 AA-0003285 LU U Z LU iD WN W LU O J_ G LL rJ V ''Z vJ project Q � J Q J ILL W Z V W UJ Or J W W 0 N _ N O U') .Q ARCHITECT RAL Z/GG�ip 7'lii/. Architecture Planning 300 Avenue of champions Suite 260 Palm Beach Gardens, Florida 33418 Phone 561.202.6990 Fax 561.296.2494 archstudiofl.com drawing FOUNDATION PLAN sheet S-1 BRACING NOTES: 1. BRACING 5HOW'N DOES NOT INCLUDE TEMPORARY BRACING REQUIRED FOR THE ERECTION AND INSTALLATION OF TRUSSES PRIOR TO TIE INSTALLATION OF PERMANENT CRO55 BRAGIN°6 AND WEB LATERAL BRACING REGY/IREFEN75. TEMPORARY BRACING 15 THE RESPONSIBILITY OF T'fE TRUSS INSTALLER AND .SHOULD REMAIN 1N PLACE A5 LONG AS NECE55ARY FOR THE SAFE AND ACCEPTABLE INSTALLATION OF TIE ROOF OR FLOOR (REF: BCSU. 2. PERMANENT k9V LATERAL BRACING 15 TO BE INSTALLED A5 SHOWN ON THE INDIVIDUAL TRU65 ORAWIN55 (kEB LATERAL BRACING 15 NOT SHOWN ON THIS SHFfT). PERMANENT NI,ES LATERAL BRACING 1.5 TO BE RESTRAINED TO PREVENT LATERAL MOVEMENT BY SOLID ANCHORAGE TO END XALL5, OR BY PERMANENT DIAGONAL BRACING (NOT SHOWN) IN THE PLANE OF THE NEB MEMBER AT INTERVALS NOT TO EXCEED 20 FEET ALONG CONTIM)OUS hEB BRACE (REF: BCSU. 3. PERMANENT D/AOONAL BRACING AS SHOWN ON THI5 SHEET DOES NOT INCLUDE BRACING REQUIRED FOR GABLE END STUDS OR BOTTOM CHORD OF GABLE END AT WALL. REFER TO STANDARD &ABLE END DETAIL FOR BRACING REOUIREMENT5. 4. ALL TOP CHORDS ARE ASSUMED TO BE 5HEATHED, AND ALL BOTTOM CHOR95 BRACED BY A RIGID CEILING 5Y5TEM. REFER TO INDIVIDUAL TF455 ORAW/N65 FOR BRACING REWIREhENTS OF NON-5-EATHEP TOP CHORDS AND UNSUPPORTED BOTTOM CHORDS. 5. REFER TO TPI / hCTA BC51: COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION AND BRACING METAL PLATE CONWEGTED WOOD TRU55W,, APPENDIX G, FOR RECOMMENDED SEQUENCE OF INSTALLING BRACING COMPONENTS. 6. THE STRUCTURAL ADEQUACY OF THE INDIVIDUAL TRU65 CE51ON5 TO WITHSTAND GRAVITY AND WIND LOAOINC75 A5 NELL A5 GIRDER CONNECTIONS AND LOADS ARE THE RESPON51BIL17YOF THE TRUSS DESIGNER. ANCHORAGE OF THE TRUSSES AND GIRDERS TO THE SUPPORTING STRUCTURE TO WITH57AND WIND UPLIFT 15 TIE RE5PON51BILI7Y OF THE PROXCT ENGINEER OR ARCHITECT. 7. THE BRACING FOR THE ROOF SYSTEM IS DESIGNED FOR BOTH POSITIVE 4 NEOATIVE PRESSURE AND MEETS THE REQUIREMENT5 OF 2017 FBG. BRACING LEGEND: PERMANENT 2x4 DIA60NAL BRACE RESTRAINT IN THE XPLANE OF THE NEAREST RM MEMBER AT 20'-0" INTERVALS AT APPROXIMATELY 45 DEGREE ANGLE. FASTEN TO OM05ITF 5117E OF NAB WITH 3-16d TOENAILS AND TO LATERAL BRACE WITH (5) IOd NAILS EACH INTERSECTION. (REF: BG51). HORIZONTAL BRIDGING WITH A MINIMUM 2x6 5TRONGBAGK AT 6'-0" 0/0. FASTEN TO EACH TRU55 WIiH 3-I0d NAILS AND ATTACH TO WALL5 OR OTHER RIGID POINT AT EACH END (REF: BGSI). PROVIDE OVERLAP OF AT LEAST (5) TRUSSES (FLOOR ONLY). I PERMANENT 2x4XCONT. LATERAL BRACING IN THE PLANE OF THE STRUCTURAL BOTTOM CHORD OF THE TRUSSES. FASTEN WITH 2-I0d NAILS IN EACH TRUSS. PROVIDE OVERLAP OF AT LEAST (2) TRUSSES (ROOF ONLY). ZONES 10 2 (_5EE DIAPHRAGM SCHEDULE) ZONE 3 (SEE DIAPHRAGM SCHEDULE) BRACING DETAILS: COMPRESSION hW SLOPING OR VERTICAL CONTINUOU5 PERMANENT LATERAL BRACING (G18) PERMANENT DIAGONAL BRACE NAILED TO OFF. 51M OF AM PREVEN75 LATERAL MOVEMENT AND SHOULD BE REPEATED AT APPROX. 20 FOOT INTERVALS FIGURE 36: PERMANENT OIA60NAL BRACING IN THE PLANE OF THE NEB MEMBERS PERMANENT GR055 BRACING FIGURE 37 PERMANENT BRACING IN THE PLANE OF THE AW5 FOR PITCHED TRUSSES HORIZONTAL BRIDGING WITH A MINIMUM 2xb 57RON65AGK CONNECTION TO EACH TRUSS WITH 3-I0d NAILS AND ATTACHED TO WALLS OR OTHER RIGID POINT AT EACH END (REF: 5051). PROVIDE OVERLAP OF AT LEAST (5) TRUSSES (FLOORS ONLY). SEE PLAN P16URE M: PERMANENT BRACING IN THE PLANE OF TIE hE55 FOR PARALLEL CHORD TRU55E5 BRACE 45011 45" LATERAL BRACE TIE -BEAM I BEAM SCHEDULE TYP. REINFORCING #3 HOOP5 TOP MID BTM MARK SIZE OR 5TIRRUPS/HAIRPINS REMARKS TYPICAL MASONRY BOND BEAM CONT UNLESS NOTED OTHERWISE (1) COURSE BB -I Sx8 1#5 - - NONE READ. FILLED CASTCR M HIGH 5TRENOT14 PRECAST MB-I 15x16 1#5 - 1#5 NONE READ. LINTEL FILLED CASTGRETE HIGH STRENGTH FREGA57 MB-2 PIx36 1#5 - 1#5 NONE READ. LINTEL ALL COURSES FILLED ALL BARS CONT. HOOK ENDS. B-I 12x16 2#5 - 205 0 DaTO. (CONCRETE) N/32" ROOF PLYWOOD. NAIL PER DIAPHRAGM 56HEDULE 19/32" ROOF PLYWOOD W/ IOd NAILS 0 4" O/C INTO 2x4 5P BLOCKING (FLATWI5E) x CONT. ENO. AND APPROVED NOOD TRUSSES SEE TYP. MALL SECTION FOR ACTUAL HEEL ENO. AND APPROVED WOOD TRUSSES SEE TYP. MALL SECTION FOR ACTUAL HEEL AND OVERHANG CONDITIONS AND OVERHANG CONDITIONS SEE TRU55 CONNECTOR SCHEDULE SELECT SEE TRUSS CONNECTOR SCHEDULE SELECT CONNECTOR BASED ON BRACING PLANS INSTAL] CONNECTOR SHOWN ON BRACING PLANS PER. MFR. SPECIFICATIONS INSTALL PER MFR. SPECIFICATIONS X BRACE BETYCEN EVERY TRU55 W/ 2x4 5P 1 (2) I6d END NAILS, EA. END _ 51 PLAN 2x4 P.T. BLOCKING (TIGHT TO EA. TRUSS SIDE) W/ 0.145" 0 TO. WALL I7 PA.F x3" L6. 04° O/G x CONT. •I STRUGTRURAL BEAM (1)160 NAIL _SEE PLAN SEE SCHEDULE T.O. WALL COW. TIE -BEAM I OR MASONRY BOND BEAM SEE BEAM SCHEDULE I 6" CMU WALL 1 2 s2 CONNECTION DETAIL S2 CONNECTION DETAIL 2 x 4 Sp#2 0 24" O.G. MAX. OUTRI6ER SIMPSON H5 2 X4 MIN. BLOCK'& 0 PANEL .JOINTS FOR FIRST F CLIP —� THREE TRUSSES (2-I0d TOE NAILS EA. END) 3-I0d COMMON NAILS MIN. (IYPIGAL) 2 X 4 SOUTHERN PIPE # 2 VERTICAL SCAB WNERE GROSS BRAGIN6 DOES NOT AL16N W/ TRU55 WEB USE MIN. 3-I6d NAILS 4 TOP 4 BOTT. CHORD GABLE END STIFFENER A5 REOV BY TRUSS MFG. GABLE END TRUS5 (DROPPED TOP FOR OUTR166E9) CONSTRUCTION GRADE 2 x 4 CRO55 BRACING NAILED TO EDGE OF Ist 4 3rd TRUSS AND CENTER WEB A5 SHOWN W/ MIN. 3 - IOd NAILS AS SHOWN. BRAGIN& PLACED A5 CLOSE TO TOP 4 BOTT. CHORD AS POSSIBLE 0 4'-0" 0/G (AT EVERY RAT RUN) 0 2 X 4 5p#2 X b' RAT RUNS 0 4' O.G. W/ 3-I0d NAILS AT EACH TRUSS 2-16d COM TOE NAILS 0 EACH STIFFENER P.T. 2 X,5 Sp#2 NAILER ANCHORED TO SM. W/ 1/4" TAPCON5 FASTENERS MIN. 1-1/2" PENETRATION 0 16" G/C 0" MIN, EDGE DISZKRAF:r-FACEV ND WALL BOND BEAM NNO) ETARDER NOTE: LASS 11 FASTEN GABLE END TO 2 x 5 NAILER W/ RETARDER Ibd COMMON NAILS o 6" G/G RM s 1.0 PERM) 51MP50N HETA20 STRAP 46" c/o - NAILED TO BOTT.ACED FIBER6LA55 CHORD OF GABLE TRUSS W/T-IOd COMMON NAILSOR ZONE IIG R702.T GABLE END - SECTION -WOOD SGALE:13/4"-1'-0" 15/52" 05B % ROOF SHEATHING SIMM CLIP 4 (4) TAPU (4) 1/4". eCONNECTION DETAIL S2 s TN H&AMIOKTA 1 BLOGKIN& W/ 3/I6" x2" LONG )NS TO BEAM 4 <1-1/2" 50REW5 TO BLOCKING I ( I I6I _yl 2x6 P.T. BLOCKING o V-O" O/C FASTEN EACH END TO TRU55 W/ 3-1 SIMPSON H6AMIOKTA CLIP ALONG 0/G Wl (4) SAC?" x2" LONG TAPGONL 1/4"XI-1/2" SGRE1,115 TO TRU55 $TM. GONG. TIE BEAM or MASONRY BOND BEAM (SEE PLAN) M 5/BEE HEADED STUDS -5/S" "U" BARS MAY BE USED AS AN I MELD -5 GAP PLATE Al ALTERNATIVE TO THE U-BARS A5 PREFERRED. II"xll"xl/2" 51 J 1/4" GAP PLATE STEEL COLUMN (SEE COL. 5CHED) L BASE PLATE 5 SEE COLUMN SCHEDULE s2 CONNECTION DETAIL EDGE NAILING ALONG BLK'6 x 6-0" LONG — 2x6 BRACE 0 6'-0. O/G W/ (10) Ibd NAILS, EA. END 5d NAILS TRUSS 0 4'-0" i TO BEAM 4 (4) ;HORD PERMANENT Ix4xGONT. LATERAL BRACING IN T PLANE OF THE 5TRUGTI: BOTTOM CHORD OF THE TRUSSES. FASTEN WITH 2-I0d NAILS IN EACH T1 PROVIDE OVERLAP OF LEAST (2) TRU55E5 (RO ONLY). 5'-O" V-0" MIN. MIN. I I revisions no. date (1) BLD6. DEPT. COMMENTS 09/21/20 designed --- drawn LTH checked SW date 06/01/20_PERMIT scale 1/4" = 1'-0" (U.O.N) job no. I90621_SFmm.21st Digitally signed by ,�EOF F(OR, Scott Blakeslee y NeR . Disher DN: cn=Scott Blakeslee Disher, o, S�REU PROS ".g ou, email=sdisher@arch tlare s"wm n M wa-nP sang a dy,el studiofl.com, c=US Date:2020.09.21 15:03:09-04'00' Scott Blakeslee Disher AR-0011586 AA-0003285 U z W 0 ' VJ I..f_ W 0 0 J LL Q LL LU Z � w � J L w_ U) U) z N N U) L0 O -0 project ARCHITECTURAL 5�Z V40 .0 ?0,V00 Architecture Planning 300 Avenue of Champions Suite 260 Palm Beach Gardens, Florida 3341E Phone 561.202.6990 Fax 561.296.2494 archstudio0.com drawing ROOF FRAMING & BRACING PLAN sheet S-2 F16URE 39: PERMANENT BRACING 1N THE PLANE OF THE hEB5 —SN16" BOND BEAM (PER SCHEDULE) �— b"x8" PRECAST L - LINTEL. i, FILL COLUMNS }' AND LINTEL SOLID W/ 6ROUT T 8"x8' FILLED _ELLS W/ 145 VERT. (TYP) TYP. DET. LINTEL ON COLUMN 3/4' = V-17 FILL COLUMNS AND LINTEL SOLID F—W GROUT I T.O.BB. a ro z .� BOND BEAM PER SGHED. f— HIGH 5TRENGTH PREGA5T LINTEL e;. W7REINFORGING AS REOD. SEE LINTEL SCHEDULE COLUMNS BEYOND SEE FOUNDATION PLAN TYP. DET. LINTEL ON COLUMN - 3/4" = V-17 6"x8" FILLED OP'ENINC75 R= 6-0": I GELS SEE PLAN PROVIDE 8'XS" MIN. AND COLUMN BOND BEAM COURSE SCHEDULE FOR 1 / W/ 1-05 MID. OR REINF. L 8'X8' MIN. FORMED J/ MASONRY CONC. SILL W 245 MASONRY OPENING MID. WALL OPENINGS > 6'-01: PROVIDE 8'X15" MIN. BREAK AWAY SIDE �'• BOND BEAM COURSE OF MASONRY z • . W/ 245 MID. OR COLUMN FOR 5'X&" MIN. FORMED CONTINUOUS POUR - - CONC. SILL W/ 2445 I, L MID. PROVIDE 6" MIN. I PROVIDE 8'45' PENETRATION EA. 48 FILLED CELLS W/ END 4 TIED TO — 145 VERT. DOhEL VERT. REINF. L ��^ 4, � K/ STD. A_I HOOK FOIAdDATION OR EA. END a 4'-V" O/C WHEN OPENIN6 INTERMEDIATE EXCEEDS 4'-0" F BEAM ..,..s. ....,.., 7 WIDE OUIRED WREN WIND RE515TANT PRE -CAST SILLS ARE NOT U5EID. SILL REINF. AT MASONRY OPENINGS (TYP.) 5/4' i f j I I I I F r 51 CLIP (4) TAP (4) 1/4' 15/32" 055 ROOF SHEATHING MP50N CONS XI-1/2, " I s 2x6 P.T. BLOCKING • V-O' O/C FASTEN EACH END TO TRUSS H/ 5-1 H6AMIOKTA I I I 51MP50N HSAMIOKTA CLIP ALONG BLOCKING W0/6 W(4) 3/16" x2' LONG TAPCON` 5/16" x2' LON5 �I yi 1/4"XI-1/2" 5CRENS TO TR455 BTM. TO BEAM 4 SCREWS GONG. TIE BEAM or TO BLOGKIN6 I BON MA50WY D BEAM (WE FLAN) WCONNECTION DETAIL EDGE NAILING K' ALONG BL 6 x 6-0" LONG 1-516" "U" BARS WELD TO GAP PLATE — 2X6 BRACE 0 6'-0' OX W/ (10) 16d NAILS, EA. END II"xll"xV2" STL. GAP PLATE 5TEEL COLUMN (SEE COL. 5_HEO) 4" (2) 5/8"x6" HEADED STUDS MAY BE USED AS AN T14 ALTERNATIVE TO THE U-BARS AS PREFERRED. 114. BASE PLATE T.O. WALL 1 5EE COLUMN 5_HEOULE SEE PLAN I 53 CONNECTION DETAIL 5d NAILS rRU55 a 4'-0' i TO BEAM 4 (4) ;HORD SAFE LATERAL LOADS FOR 8" PRECAST 4 PRE5IRE55ED U-LINTELS DSAFE UPLIFT LOA5 FOR 8" PRECAST 4 PRESTRE55ED U-LINTELS C4 _4~m SAFE LOAD PLF LENGTH TYPE BUB BF8 .. 2'-10'(341 PRECAST 1293 1642 2135 S-6- (421 PRECAST 1025 1024 1830 4'-0' (481 PRECAST 765 763 1365 4'-6- (54' PRECAST 592 591 1057 5'-4- (64' PRECAST 411 411 734 5'-10'(701 PRECAST 340 339 607 6'-6- (781 PRECAST 507 721 493 7'-6- (901 PRECAST 424 534 357 9'-4- (1121 PRECAST 326 512 227 10'-6-(126' PRECAST 284 401 178 ll'-4'(136' PRECAST 260 452 152 12'-0'(144' PRECAST 244 402 135 1S-4-(160' PRECAST 217 324 109 14'-0'(168' PRECAST 205 293 98 14'-8'(1761 PRESTRESSED N.R. 254 89 15'-4-(184' PRESTRESSED N.R. 259 82 17'-4'(2081 PRESTRESSED N.R. 194 63 19'-4'(2321 PRESTRESSED N.R. 148 51 21'-4-(2561 PRESTRESSED N.R. 125 42 22'-0"(2641 PRESTRESSED N.R. 116 39 24'-O'(2881 PRESTRESSED N.R. 91 33 4AMP-444Nm SAFE LOAD - POUNDS PER LINEAR FOOT TYPE LENGTH 8FB-IT SF12-IT 81`16-IT SF20-IT BF24-IT SF28-IT 8FS2-1T M-ZT 8n2-Zr SF16-2r W,*-2T BF24-Zr 928-71' FM-2T 2°-90°(34') PRECAST 1972 3173 4480 5747 7034 8321 986 1972 3173 4460 5747 7034 9321 9808 3'-6- (42' PRECAST 15N 2524 3547 45N 559E 6613 763E 15N 2.524 3547 46N SN1 N13 7638 4'-0' (48' PRECAST 1363 2192 3079 39N 4853 5740 8627 1393 2192 3072 3866 403 5740 66Z7 _ 4'-6- (54' PRECAST 1207 1940 2724 3506 4292 5077 1 5N7 1297 1940 ZM 35M 4292 ISM 5561 5'-4' (64' PRECAST 1016 163 2290 2949 3407 4265 4924 1018 7632 2290 2849 3607 4785 4824 5'-10-(70' PRECAST 909 1402 2003 2604 3295 3B97 4408 929 1402 2093 2694 3295 3597 4408 W-6- (781 PRECAST BY 12 INO IND 2419 201 3498 4038 8335 1340 1880 2419 20M AM 4038 ' V-6- (901 PRECAST _ 727 1021 16X12 211t) 257E 10 10 3506 9 727 1166 1634 2102 2571 3039 3508 9'-4- (1121 PRECAST 591 NO 11 15 147 1 1811 15 21 16 24K15 591 051 1326 1705 2084 2463 2842 10'-B'(126' PRECAST 570 55 914 1 116 151 1458 15' 173215 1 530 688 1183 1526 IBM 22D4 2544 ll'-4-(1381 PRECAST 474 _ 485 706(15 IOX15 127215 151 15 17 1 494 _ 599 1028 1422 1738 2053 23N 12'-0-(144') PRECAST 4A ® µ1 72114 936 14 115115 1369151 1 15 470 543 m130 16N 1948 2247 13'-4'(1601 PRECAST 418 15 373 606 14g723 962 14 114114 1321 14 428 485 770 1444 1718 1N3 14'-0' (168' PRECAST 384 is 348 559 14 897 14 1 14 121 14 410 420 709 1434 1BB4 195414'-8°(176' PRESTRESSED 239 323 519 13 V3 i 978 14 11 14246 380 6551324 8 9 11 187 it15'-4'(184' PRESTRESSED 224 302 485 1 767 1 9tm 1 1 t230 364 N91224 8 t 74 18011417'-4-(208' PRESTRESSED 255 404 t2 637 12 754 t 672 12 192 303 500 732 9B7 8 12 14 14 14 19'-4"(232' PRESTRESSED 162 222 347 11 448 1 5411 12 646 12 746 12 iN 261 424 616 931 8 1 14 1 14 21'-4'(256' PRESTRESSED 142 198 306 tt 393 11 48O 1t 567 1t &54 11 142 23D 3% 531 713 803 1 1 13 22'-0'(264' PRESTRESSED 137 192 295 10 378 11 461 10 545 11 829 11 137 221 354 5N N1 8811 9971 24'-0'(288' PRESTRESSED 124 975 267 10 341 10 416 10 401 10 5N 10 124 318 45D � 756 12 95 1 (1) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR GR40 FIELD ADDED REBAR. SAFE GRAVITY LOAD5 FOR a" PRECAST 4 PRESTRESSED U-LINTELS 4twr-444r m SAFE LOAD —POUNDS PER LINEAR FOOT TYPE LENGTH 6U8 BF8-M BF12-46 BF16-0e BF20-08 Br__ e___ BF3z� BF8-18 BF12-19 W16-16 SF2D-16 OF24-18 OF20-10 *M-1R 2'-10"(34� PRECAST 2231 JON 46M 6113 7547 M74 10394 11809 SON 4805 8113 7547 N74 10N4 11809 3'-6' (42' PRECAST 2231 30% 3719 5163 6007 8054 9502 10051 SON 46M 6113 7547 8974 10N4 1180E 4' 0° (487 PRECAST 1968 2561 X151 3820 4800 5981 70M 8107 2593 4605 SIM 7547 8974 10394 118M 4'-8' (54' PRECAST 159E 19N 2110 1 2931 3753 4576 5400 8224 21M 4= 6113 7547M U72 IM94 11800 5'-4' (641 PRECAST 1217 1349 1438 19N 25M 3123 3M 4249 1663 3090 5385 7547 7MXI9 87919 1012 19 5'-10'(70' PRECAST 1062 1105 1173 1631 2090 256 300E 3470 1451 28Z2 4WD 71 45 19 &VA 6'-6' (78' PRECAST 908 1238 2177 3460 3031 SW _nglq 430 5061 1238 2177 3400 5351 &T60 1 14 i-8' (90' PRECAST 743 1011 172E 2632 22D5 2698 3191 3685 ton 1726 2661 3898 5881 8487 44 6472 15 9'-4' (112' PRECAST 554 m 1160 1 1525 2564 3406 2818 3302 752 1 1245 1 1W 2564 3406 4705 040 4 10'-O'(1261 PRECAST 475 SJo 5 N 1247 2093 7M 2163 25M 843 1052 1533 2063 2781 3843 38 4754 45 ll'-4'(1361 PRM4ST 382 582 m 13M 184a 2423 3127 4006 582 945 1366 1846 2423 3127 4006 12'-0'(144' PRECAST 337 540 an 1254 1684 2193 2805 355z 640 673 1254 1654 2193 2005 3552 13'-4-(1807 PRECAST 296 471 755 1075 1426 104 2316 2883 471 755 1075 1426 1838 2316 2N3 14'-0-(168' PRECAST 279 424 705 1002 1325 1097 2127 2630 442 706 1002 1328 1097 2127 2630 14'-8'(176' PRESTRESSED N.R. NR NR NR NR NR NR NR 456 7Ba 1370 1902 2245 2517 2712 15'-4-(1841 PRESTRESSED NA NR NR NR NR NR NR NR 412 710 1250 1733 2D58 2320 2513 17'-4-(2081 PRESTRESSED NA NR NR NR NR NR NR N! 300 548 950 1326 18M 184E 2047 19'4'(232") PRESTRESSED N.R. NR NR NR NR NR NR NR 235 1 420 1 750 1037 1282 1515 1716 21'-e(2561 PRESTRESSED N.R. NR NR NC NR NC N4 NR 180 340 5N N5 1114 1359 1468 22'-0"(264' PRESTRESSED N.R. NR NR NR NR NR NR NR 155 315 550 784 1047 1285 I= 24'-0'(288' PRESTRESSED N.R. NR NR NR NR xR NR NR 120 250 450 1 1154 8B4 1092 1222 .. i (1) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR GR40 FIELD ADDED REBAR. i 1/3 S-1 -"E" BAR RIVETED TRUSS ANCHOR SCHEDULE (10d cam°170 MPH ASCE CONCRETE TIE -BEAM TO TRUSS EXP 11CF° REV.01/2014 7-10) A°4 NU2'BER OF STRAPS FLa. PROD. APP. NO. SIZE -` 4� PRODUCT CODE l51MP50N) GAUGE DIMEN510NO NUMBER OF (COM. NAILS) ALLOWABLE LOADS - LATERAL UPLIFT (AT 160% ON WOOD) TOTAL LATERAL (F2) OUT OF CONCRETE (HEIGHT) EMBEDMENT FI F2 IN GONG. 3 20 PSI IN GROUTED CMU IS5 1 243 1 292 1 341 1 388 431 MARK FiEMAINING5 UPLIFT CAPACITY A-1 I FL11413 20 WETA 20 Ib 16 4 9 340 125 1810 NO 1320 1200 1080 960 1842 120 I IFL11413 20 HETAL 20 16 15 5 M& 14 • 415 1100 1810 _ 1510 1489 1410 1329 1248 11112 IO91 A-3 2 FL11413 12 EACH - Ibd 2354 2268 21BI 21W 2010 1524 A-4 FL11413 TA 2 Ib Ib 4 10-10d x I W 14 2035 1161 1694 1625 1536 14W 1421 A-5 2 FL11413 20 DETAL 20 16 16 1 41/2 24-10d x 1 V2 • 2000 1310 2480 24W 2100 2040 1550 1860 1115 1690 )2 . 2L 2 (F9C TABLE 16062A) X 2' (TRUSS SPACING) X WALL H X .42 X 1.4 (EXPOSURE C) ZONE � p = 21.2 (1.4) (EXPOSURE G) = 29 PSF HT. = 30' 8'-0" 10'-0" 12'-0" 41'-0" 1&'-0" V-0" 1 WALL HEIGHTS - USE ALL FASTENERS IN SCHEDULE TO ACHIEVE VALUES INDICATED. MINIMUM EDGE DISTANCE IS 2" - ALLOW 4• EMBEDMENT IN CONCRETE (UNLESS NOTED OTHER911SE) - WITH A RIVETED BEAM SEAT, EITHER STRAP YIELDS SAME UPLIFT. - DESIGN LOADS BASED ON USE OF SOUTHERN YELLOW PINE, $G•0.55 ( NO INCREASE ON STEEL STRESS) • INSTALL 5 NAILS INTO TRUSS SEAT FOR WETAL20 • INSTALL 6 NAILS INTO TRJ65 SEAT FOR DETAL20 EA. SIDE. NOTE: STRAPS ARE ETA AND SEATS ARE TSS. IN HETAL STRAPS PROVIDE (5) NAILS AT SEAT. (PROVIDE ONE BEAM SEAT PER SIDE 4 MOISTURE BARRIER AS REQUIRED) — J" BTUAN. STRAPS MAX. 2 MEMBER G.T. P2FOR A3 1� I MEMBER G.T. FOR A4 I MEMBER WT: fl� F� FOR A5 .� 1 I 1 1/2" MIN. •.. EDGE DIST (TYP) 15/8" MIN. MULTIPLE RIVETED TRUSS GLLl S I in" MIN. / EDGE DIST (TYP) 4" BETWEEN STRAPS SINGLE RIVETED TRUSS ANCHI - (MIN) (TYP) EMBEDMENT LATERAL LOADS ON TRUSS ANCHORS LATERAL HIND LOADS FOR TRUSS CONNECTIONS HAVE BEEN DESIGNED BY RATIONAL ANALYSIS FOR THE ACTUAL LATERAL LOADS AND DO NOT EXCEED THE ALLOKABLE LATERAL LOADS L15TED ON THE STRAP CONNECTION SCHEDULE INCLUDED ABOVE. FOLLOW STRAP MANUFACTURER INSTALLATION INSTRUCTIONS. PLYWOOD FLOOR / ROOF SHEAR DIAPHRAGM SCHEDULE FRAMING/ TRU55 MINIMUM PANEL NAIL SPACING COMMON NAIL FLOOR PANEL GRADE SPACING THICKNESS SIZE REMARKS DIAPHRAGM BOUNDRIES ®OTHER PANEL EDGES 2ND FLOOR 5RD FLOOR N/A APA RATED 5HEATHING 2'-0" 5/6" 4" a ZONE 2 4 5 4' a ZONE 2 4 3 11N8L0GKED DIAPHRAGM ROOF EXP. I, OR EQUAL. MAX. Nam. 6" a ZONE 1 6" t9 ZONE I bd RING SHANK UNO-5EE 07L5. NOTES: I. INSTALL PLYWOOD PANELS AS 54ONN ON DETAIL BELOW: BLOGKIN6 (IF REOVJ E FRAMING HIP (DIRECTION OF KID. TRUSSES OR FRAMING) B I m1i 91 1 2. SPACE NAILS o 45" O.G. ALONG INTERMEDIATE FRAMfN6 MEMBER5 FOR FLOORS, AND 6" O.G. FOR ROOFS. S-1 _ S-1 S-1 1/3 S-1 1/3 S-1 1/3 S-1 1/3 S-1 1/3 S-1 1/2 S-1 BAR (TYP.) \ BOTT. BAR (TYP) !—SHEAR REINFORCING SPACED FROM 4" TYP. SUPPORT AS SCHEDULED I pag;y�_ LOA mni_�I�tlzl revisions no. date designed drawn LTH checked 55D date 06/01/20 (PERMIT SET) scale 1/4" = I' -ON WON) jot) no. 190621_5F-21.Ih Scott Blakeslee Disher AIR-0011586 AA-0003285 0 ) 11 e Ate LU O 5. ZONES 1,2 4 5 ARE A5 SHOWN BELOW: 2 4'-0" 4 _0. (INCLUDING OVERHANG) � J QILL. w LL- I LU OI �----- --I ®� OC / �— — — — CABLE END J LU W_ N V / cv ~ 04 L-- — -- -- I rZ 0 irk 4'-0" INGLUDIN6 O.H. project �HITECT t iri s 'i'1/�fa (TYP.) BOTT. BAR (TYP) y✓ (TYP.) BOTT. BAR TOP BARS IN BOND 13M. UNIT SHEAR REINF. AS REQUIRED BM. GROUTED SOLID THRI-OUT- (VIBRATE GROUT IN PLADE=) BOTT. MARS IN — PRECAST COMICRZ LINTEL UNIT. BEAM SECTION �o L6 LP 1/4 SPAN TI L6 LP 1/4 SPAN TI BEAM TOP REINFORCING Lai Z BEAM BOTT. I REINFORCING VERT. WALL REINFORCING. REINFORCED REINFORCED MASONRY WALL MASONRY BEAM TYPICAL MASONRY BLAM BENDING DIAGRAM BEAM BOTTOM BARS MAY BE GONTINUOV- OVER 5UPPORT5 WHERE APPLICABLE Architecture Planning 300 Avenue of Champions Suite 260 Palm Beach Gardens, Florida 33418 Phone 561.202.6990 Fax 561.296.2494 archstudio0.com drawing sheet S-3 F i �1 .r eT- 250 AMP ELEC. PANEL "A11 10,000 AIC RATED GIRG. DESCRIPTION POLE BKR WIRE KVA. 100% 100% KVA. WIRE BKR POLE DESCRIPTION GIRD. I -- AHU #I HEAT STRIP ------------ 2 --- --- 60 -- -- b --- --- O -- -- 9.6 --- --- O --- --- O -- -- H --- --- 40 -- -- 2 --- --- AGGU �I -------------F- ------------ ----------------- 3 4 -- 5 GOOK TOP 250 b 12 O I 5.0 IO 30 2 DRYER b H 9 WATER HEATER 2 25 10 4S O --- O 1.5 12 20 1 ---_---WASHER 10 11 1 1.0 12 20 - I- GOOK TOP. HOOD 12 13 WALL OVEN 2 50 b 12 O --- 1 1.0 12 20 I 6AR5A6E DISPOSAL 14 IS O 1.2 12 20 I -----DISHWASHER 16 17 MICROWAVE I 20 121.5 --0 ----0- 0.5 12 20 I GARAGE 6FI'S IH ],I-- REF./FREZ. ---- ------- I --- 20 -- 12 --- 1.2 -- -0- O --- 0.5 -- 12 --- 20 -- I -- ----- BATH 6FI'S 20 -- 21 SMALL APPLIANCE 1 20 12 1.5 -0- O 0.4 12 20 1 --- GARAGE DOOR 22 23 SMALL APPLIANCE 1 20 12 1.5 O 0 * 14 I5 1 GENIERP.L LIGHTING 24 25 SMALL APPLI ANGE 1 20 12 1.5 O O • 14 15 I GENERAL LIGHTING 26 2? -- GENERAL LIGHTING ------------ I --- IS --. 14 --- ' -- O --- 0 --- # -- 14 ---.-- 15 1 --- GENERAL LIGHTING ------------ 26 -- 29 GENERAL LIGHTING 1 15 14 '" O O • 14 15 I GENERAL LIGHTING 30 51 GENERAL 1-16HTIN6 15 14 "- O 0 - 14 15 I GENERAL LIGHTING 32 33 GENERAL LIGHTING IS 14 • O O * 14 15 I GENERAL LIGHTING 34 35 - POOL 5UB-PANEL OPTION ------------ 2 - - - 6 -- 65 - - - 915 -- O --- - - - O O " ' 14 14 15 -- 15 1 --- 1 GENERAL LIGHTING ------------ GENERAL 1-161-1TIN6 36 -- 5e, 5i 39 SPARE --------SPARE 40 41 SPARE SPARE 42 SUBTOTAL 3i. 09.6 O 11.1 * GENERAL L16HTIN6 = 1,610 (50.FT) X 3 (KATT5/50.FT) = 4,650 / 12 (GEN.LT6.GIR) = 402.5 (WATT5/EA) TOTAL (NO A/C) = 4H.40 Ist 10,000 at 100% = 10.00 REMAINDER AT 40% = 15.36 A/C LOAD AT 65% = 6.24 TOTAL = 3I b0 x 1000 / 240 = 151.66 AMPS THIS PANEL ELECTRICAL NOTES A. HEAT STRIP LOAD GOVERNS OVER CONDENSOR UNIT LOAD. B. CONDUIT SIZE. C. 5EE 5UB-PANEL CALCULATIONS. R. BRANCH CIRCUITS RUN IN ROMEX. A.I.C. CALCULATIONS (2 x 40 x 26,194)/(5000 x 240) = L-15 1/1 + 1.95 = 36.36 x 26,194 = 9525.09 A.I.G. OF SERVICE = 1525.09 A.I.G. RATING OF PANEL = IOp00 DINING LANAI F R\ '------� I\T. ROUGH114 FOR \I \ F / FAMILY \ � ROOM RAISED WP 6F1 / J�TE�j / 1-4— / IN FOR P FAN 4HLIGHT I OSUITS I E F ROUGH IN FOR FAN d LIGHT OPT. RAISED TV ELEC. �j OPT. OPT. / OUTLETS revisions no. date designed -- drawn LTH checked 55D date 06/01/20 (PERMIT SET) scale 1/4" = 1'-O' (U.O.N) jot) no. 1906Z-5F-21.lh 4 Scott Blakeslee Disher AR-0011586 M-0003285 I - \ W '0OFT' J J I U z ® — — — — -�— THEN REF W a I DW I F Q / DBL. SINK <7 W/0I5POSAL (J) I W \ W/ MICRO A/ ABV. LI- - — — TRY W NE WBATH 6FI 6FI GPI 5FI Q 6F1 0 r--- r--- C I I I I BEDROOM 3 J Q< I I _ v C • I I F FR�L GHOR Uj > O F— Q Q w —LT =oIGA LERYI LL z L � cf �- o J GHII�E I W � O Of W I II o a z c�4 BATH 2 L— — J I I U') U- -0 ® project LAUND DISC II DISCARCHITECT RAL PANEL 'A' METER d x�• DRYER S sM �® II FOY R L LT. i REVIEWED FOR CODE COMPLIX t+ n'G• ST. LUCIE COUNTY BOCIC ® CAR GARAGE Architecture ■ V15FI Planning DOOR BEDROO 2 OPENER I I 300 Avenue of (ham Ions IN FOR (� P F FAN E LIGHT I I FILE COIF Suite 260 I I Palm Beach Gardens, Florida 33418 PO H I I Phone 561.202.6990 T ( I Fax 561.296.2494 archstudio0.com I I m drawing ELECTRICAL PLAN sheet E-1 PLUMBING NOTES ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE AND SHALL COMPLY WITH ALL LOCAL RULES OF FLORIDA BUILDING CODE 6TH EDITION (2011) PLUMBING WITH ALL AMENDMENTS AND ORDINANCES. I. ALL WORKMANSHIP 4 MATERIAL-5 SHALL BE IN STRICT ACCORDANCE WITH FBG / FBG-R 2011 6TH. ED. APPLICABLE NATIONAL, STATE, LOCAL CODES, RULE5 4 ORDINANCES. 2. CONTRACTOR SHALL V151T THE JOB SITE 4 THOROUGHLY FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 3. ALL MATERIAL5 SHALL BE NEH. 4. ALL HORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST-CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL BE FULLY OPERATIVE. 5. ALL EXCAVATION 4 BACK FILL A5 REQUIRED FOR TH15 PHASE OF CONSTRUCTION SHALL BE A PART OF THIS CONTRACT. 6. REQUIRED INSURANCE SHALL BE PROVIDED BY TH15 CONTRACTOR FOR PROTECTION A&AIN5T PUBLIC LIABILITY 4 PROPERTY DAMAGE FOR THE DURATION OF HORK. 1. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS 4 TEST. 505TITUTION5 BY THE CONTRACTOR SHALL HAVE PRIOR APPROVAL. ANY CHAN6E5 MADE WITHOUT APPROVAL HILL BE PAID BY THE CONTRACTOR TO RETURN TO THE ORIGINAL DE516N. 6. DRAWIN65 ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXALT LOCATION OF FIXTURES, PIPING, EQUIPMENT, M. 9. ALL HORK SHALL BE COORDINATED WITH OTHER TRADE5 TO AVOID INTERFERENCE WITH THE PROGE55 OF CON5TRUGTION. 10. VERIFY LOCATION, SIZE, TRAPS, INVERTS OF ALL EXI5TIN6 UTILITIES PRIOR TO BE6INNIN6 CONSTRUCTION, ADV15E ENGINEER OF ANY 015GRE2ANGIES. ANY COST RESULTING FROM DISCREPANCIES NOT REPORTED AT TH15 TIME SHALL BE PAID BY THE CONTRACTOR. 11. HATER PIPING TO BE COPPER, PEX TUBE, OR PVC DEPENDING ON PROJECT REOUIREMENTS, AND/OR AVAILABILITY. 12. SOIL, HASTE 4 VENT PIPING TO BE PVC. #40 DVW. 13. ALL FIXTURE5 MUST BE PROVIDED HITH READILY ACGE551BLE 5TOP5, AND MEET THE REOUIREMENT5 OF CHAPTER 6, TABLE 604.3, 604.4, 6045 14. INDIVIDUAL 51401,11ER 4 TUB/SHOWER COMBINATION VALVES SHALL BE EQUIPPED WITH CONTROL VALVES OF PRESSURE -BALANCE, THERMOSTATIC MIXIN6 OR COMBINATION PRESSURE -BALANCE / THERM05TATIG-MIXIN6 VALVE TYPES WITH A HIGH LIMIT STOP IN A55E 101b OR GSA 5125 ( PER F.B.C. P2'108.3) 15. HHERE DISSIMILAR METALS ARE TO BE JOINED, APPROVED INSULATING UNIONS SHALL BE USED. 16. CONDENSATE LINES TO BE COPPER/PVC DEPENDIN6 ON PROJECT REQUIREMENTS. INSULATE WITH I/2" THICK ARMAFLEX INSULATION. 1-7. CONTRACTOR SHALL 6UARANTEE ALL MATERIALS 4 HORKMAN5HIP FREE FROM DEFECT5 FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED HITHIOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 16. NO PVG PIPING TO BE USED IN COMMON PLENUM AREAS. I9. IN5PECTION AND TE5TIN6 OF BAGKFLOW FREVENTION A55EM5LIE5 PER 20I1 FPG, 6TH ED. SEGTION5 312.10, 312.12.I.AND 512.10.2 PLUMBING FIXTURE SCHEDULE FIXTURE TRAP 51ZE GOLD WATER HOT WATER FIXTURE UNITS H40 3" I\2" - 6 LAV 1-1/2" 1\2" 1\2" 5 5HIOWER 2" 1\2" I\2" 2 KITCHEN SINK 1-1\2" \2" 1\2" 2 AM 2" \2" 1\2" 2 DW 1" 5H - 2 HB - I/2" - 2 TUB 2" 1\2" 1\2" 2 BIDET - - NA TOTAL 21 1) FIXTURES TO COMPLY W/FBG PLUMBING SECTIONS -701.1,605.1 4 604.5 2) ANTI -SCALD VALVE: ALL 5WIIER5 4 BATH/SHOWER C.OMBINATION5 SHALL BE PROTECTED WITH A CONTROL VALVE OF THE PRESSURE BALANCE, THERMOSTATIC MIXING OR COMBINATION TYPE SET. HANDLE P051TION STOPS PER MANUFACTURERS INSTRUCTIONS AT TIME OF IN5TALLATION TO A MAXIMUM MIXED WATER OUTLET TEMPERATURE OF 120" F. JI J GU GOLD WATER SUPPLY TO WATER HEATER INTERNAL HEAT TRAP (FBC B-13-6-612.IAB6.2.2) PROVIDE A 210'F TEMPERATURE TO HOT WATER FIXTURES AND TO P51 PRESSURE RELIEF AS 5HOWN ON PLAN5 VALVE WITH TEST LEVER 51ZED NOTE: WITH ACA/05A TEMPERATURE EXTEND CONDENSATE DISGHARCE STEAM RATING 10% OVER HEATER TO MINIMUM OF 12 INCHIE5 FROM INPUT BUILDING'S EXTERIOR WALL. THERMOSTAT AND 6005E NECK PRE59JRE REGULATOR PROVIDE A HARD RELIEF FURNISHED WITH VALVE DISCHARGE LINE FULL WATER HEATER SIZE OF VALVE OUTLET TO RUN N TO EXTERIOR OF BUILDING OR - NEAREST APPROVED INDIRECT WASTE DRAIN VALVE BY MIN. 5/4' WATTE PIPE, EXTEND HEATER MANUF. / TO BLD6. EXTERIOR 4 TERMINATE MIN. 6"/MAX. 24" ABV. GRADE. MIN 246a 6ALV. STEEL PAN MIN. CONDENSATION DISCHARGE DETAIL O 1 1/2' DEEP H/MIN. 3/4' HASTE 4�- PIPE SET HEATER THERMOSTAT TO 120'F WATER HEATER DIAGRAM 1212W* 4:4 2'4' STAND H. 4 GIN 5UPPLY WASHING MACHINE BOX N.T.S. N.T.S. N.T.S. PLUMBING RISER DIAGRAM N.T.S. G.J• J1GG G fU1U PP QRGG1G1t✓ I STUB & N\ L A 1/ ' I L VIP Z III I SGPTIG A.A.V. A.A.V. MINI -VENT MINI -VENT 11/2' TRAP TRAP OR 2. OR 5" 2" OR 5. AIR ADMITTANCE VALVE (A.A.V.) DIAGRAM L111111161 LAUND 1'-4' CLE LANAI 9'-4" GL6. DINING 9'-4" GL6. STUB 4GAP IN CEILIN6 OWNERS SUITE W-4" GL6. 0 0 y BATH v " /22" 11F- 1 I WIC 4' 4" 6L6. ' I I I I 22y*. I I I I TMW u. ( I I IGALLERYIF( ,2' - - - I 9'-4' to 10'-0' 1 GOFF. GL6. 1/2' 0 1/2" 11 I ( II 3/4" 3ATH2 9'-4' GL6. I 1 II I' II I I II FOYER 9'-4' 61.6. F.#x� TnL Lw�x. L FAMILY ROOM 9'-4" 01.6. V..r1TI�E7 -OFF-VALVE N6 MACHINE BOX L, HEN REFJ CI-6.FREEZ. 11 BEDrd�I 2M 3 9' 4 GL6. II II 2 CAR GARAGE 9'-4" GL6. revisions no. date OEWED FOR i COMPLIP. project "JCIE COUN. BOCC 0 ARCHITLk ECT KAL VvVV A h;t t rc I ec ure Planning 300 Avenue of Champions Suite 260 Palm Beach Gardens, Florida 33418 Phone 561.202.6990 Fax 561.296.2494 archstudiofl.com drawing PLUMBING PLAN sheet P-1 GENERAL AIR CONDITIONING NOTES MECHANICAL EQUIPMENT NOTES: 1. THESE DRAWINGS ARE RESULTING INSTALLATION ARE INTENDED TO COMPLY WITH: 1.. ALL MECHANICAL EQUIPMENT SHALL BE ARI & U.L. LISTED WHERE APPLICABLE SEE ADDITIONAL COMPLIANCE NOTES. AND RATED FOR THE REQUIRED SERVICE, PRESSURES, TEMPERATURES, AND 2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARILY SHOWING SHALL BE PROVIDED WITH ALL NECESSARY TRANSFORMERS, SEALS, VALVES, IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS. UNLESS SPECIFIC DIMENSIONS CONNECTIONS, ETC. TO FUNCTION PROPERLY. 2. PROVIDE SMOKE DETECTORS WITH ACCESS DOORS IN ALL SUPPLY AIR DUCTS ARE SHOWN, THE STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN THE EXACT LOCATIONS.. CONTRACTOR. SHALL FOLLOW DRAWINGS IN LAYING FOR FANS AND AHU'S ABOVE 2000 CFM. ALL SMOKE DETECTORS SHALL BE BY OUT WORK, CHECK DRAWINGS OF ALL TRADES TO VERIFY SPACES IN WHICH WORK ONE MANUFACTURER; COORDINATE VOLTAGE ETC. WITH ELECTRICAL CONTRACTOR AND FIRE ALARM SYSTEM BEFORE ORDERING. UPON DETECTION, WILL BE INSTALLED AND MAINTAIN MAXIMUM HEADROOM, AND SPACE CONDITIONS SMOKE DETECTORS SHALL SHUT DOWN ASSOCIATED AIR MOVING EQUIPMENT AT ALL POIN.T.S.. WHERE HEAD ROOM, OR SPACE CONDITIONS APPEAR SERVINGCOMMON AND L AJR MOVING THAT INADEQUATE, ARCHITECT/ENGINEER SHALL BE NOTIFIED BEFORE PROCEEDING WITH 3.. PROVI ETYPE"B"FIRE DDAMPE S INLDUCTS OR OPENINGS PENETRATING INSTALLATION. THIS CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD FIRE RATED WALLS, PARTITIONS, FLOORS OR ROOF SLABS AND AT FRESH AIR MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF INTAKES IF REQUIRED (SEE ARCHITECTS PLANS FOR RATINGS). PROVIDE VARIOUS TRADE OF FOR PROPER EXECUTION OF THE WORK. RADIATION DAMPERS IN RATED CEILINGS FOR ALL CEILING OPENINGS, CEILING 3. EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID. CONTRACTOR FANS, DIFFUSERS OR. GRILLS RATED FOR USE IN THE CEILING ASSEMBLY AS WILL BE REQUIRED TO FURNISH, INSTALL AND/OR CONNECT WITH APPROPRIATE SPECIFIED BY ARCHITECT. SERVICES ALL AIR CONDITIONING ITEMS SHOWN ON ANY OF THE ARCHITECTURAL, 4. PROVIDE BACKDRAFT DAMPERS ON ALL EXHAUST FANS AND/OR INUNE FANS. PLUMBING, ELECTRICAL AND SPRINKLER DRAWINGS. WITHOUT ADDITIONAL EXPENSE 5. PROVIDE. VIBRATION ISOLATORS ON ALL MECHANICAL EQUIPMENT AS SPECIFIED TO THE OWNER. IF DISCREPANCIES, CONFLICTS, INTERFERENCES OR OMISSIONS IN THE DRAWINGS. IF NOT SPECIFIED, AS RECOMMENDED BY MANUFACTURER OCCUR BETWEEN DRAWINGS, NOTIFY IN WRITING THE ARCHITECT/ENGINEER IN - FOR QUIET OPERATION (WITH 99 % ISOLATION EFFICIENCY). AMPLE TIME TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED. 6. PROVIDE A MIN. OF 10' CLEARANCE EETWEEN O/A INTAKES AND VTR OR 4. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST CLASS WORKMANLIKE EXHAUST OPENINGS. 7. THERMOSTAT LOCATION SHALL BE APPROVED BY OWNER AND ENGINEER BEFORE MANNER. THE OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEMENT: INSTALLATION (48" A.F.F.). OF ITEMS, WHICH, IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE 8. RUN INSULATED CONDENSATE DRAINS AS PER PLUMBING DRAWINGS. APPEARANCE. REMOVAL AND. REPLACEMENT IS TO BE DONE IMMEDIATELY WHEN 9• MOUNT ALL ROOFTOP EQUIPMENT FOR WIND LOADS AND MOUNTING HEIGHTS AS DIRECTED BY THE OWNER IN WRITING, AT THE SOLE EXPENSE OF CONTRACTOR. REQUIRED BY LOCAL CODS, ALL CURBS SHALL EXTEND 8" MIN. ABOVE 5. START OF WORK BY CONTRACTOR $HALL BE CONSIDERED AS ACCEPTANCE BY HIM FINISHED ROOF. OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER 10 ALL PIPING AND DUCTWORK SHALL EE SLEEVED THRU WALLS, BEAMS, SLABS, TRADES OR OTHER.. CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACTOR . ETC, AS REQUIRED AND NATEC WITH ENGINEER. REWORK SHALL REMOVE AND REPLACE, AT HIS .EXPENSE, ALL AIR CONDITIONING WORK LNGCOOA ECES ARYT RAN BAR .JOIST CROSS BRACING AND PR)VIDE NECESSARY TRANSITIONS AS WHICH MAY HAVE TO BE REMOVED BECAUSE OF INTERFERENCE WITH OTHER REQUIRED FOR DUCTWORK INSTALLKION. TRADES. 11. ALL INSULATION WILL HAVE FIRE/SM(KE RATING LESS THAN 25/50. 6. THE CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, FEES, PERMITS 12. PROVIDE MOTOR STARTERS AS FOLLGNS (UNLESS OTHERWISE RECOMMENDED BY ASSOCIATION DUES, ROYALTIES, AND TAXES OF WHATEVER NATURE SHALL APPLY TO MOTOR MANUFACTURER): THIS WORK. HE SHALL ALSO PAY ALL INSPECTION FEES AS MAY BE REQUIRED BY A PROVIDE OVERLOAD PROTECTION - 1/3 HP AND ABOVE (ALL PHASES).. LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY DAMAGE B. PROVIDE ACROSS THE LINE WLTAGE STARTING BELOW 25 HP. AND EXPENSE ARISING FROM ANY VIOLATION OF THE LAWS, RULES OR C. REDUCED VOLTAGE MOTOR STARTER FOR 25 HP AND ABOVE. ORDINANCES. 13. ALL OUTDOOR EQUIPMENT SHALL COAPLY WITH LOCAL ZONING NOISE 7. THE WORD "AIR CONDITIONING" MEANS HEATING, VENTILATION, AIR CONDITIONING, ORDINANCES. MIN. REQUIREMENT SALL NOT EXCEED A NOISE LEVEL OF 65 DB DUCTWORK, PIPING, REFRIGERANT LINES, CONTROLS, SMOKE AND FIRE DAMPERS AS MEASURED RADIALLY 30 PT ROM THE EQUIPMENT IN ALL DIRECTIONS. 14. FILTERS SHALL BE IN PLACE DURING CONSTRUCTION. PROVIDE A NEW SET. ETC _ 15. PROVIDE FLEXIBLE CONNECTION FOR (RUBBER EXPANSION JOINT) FOR THE 8. PROVIDE MEANS "FURNISH AND INSTALL". CONDENSER WATER PIPE ON THE SYCTION AND DISCHARGE SIDE OF THE PUMP, 9..-DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE... HEAT EXCHANGER AND COOLING TOYER. FLEXIBLE CONNECTION TO BE TWIN 10. SHOP DRAWINGS: THE CONTRACTOR SHALL FURNISH THE ENGINEER WITH SHOP SPHERE FROM API INTERNATIONAL TZT SERIES. DRAWINGS OF EQUIPMENT PRIOR T0. PURCHASE FOR APPROVAL.. 16 PROVIDE 1' ISOLATION PAD UNDER CAMP AT ALL PIPE PENETRATION ON THE 11. AT COMPLETION OF JOB THE HVAC CONTRACTOR SHALL GIVE THE OWNER AN . SLAB. AS -BUILT SET OF REPRODUCIBLE DRAWINGS SHOWING THE EXACT AND COMPLETE 17. PROVIDE 10" INERTIA BLOCK "MASON BMK"FOR ALL PUMPS. INSTALLATION. 18. ALL PIPE ABOVE 12" IN DIAMETER RUNNING HORIZONTALLY MUST. BE HANGED 12. ALL DUCT SIZES ARE IN INCHES AND REPRESENT CLEAR INSIDE DIMENSIONS. FROM ADJUSTABLES STEEL YOKE PIPE ROLL WITH SPRING ISOLATORS. PIPES 12" 13. THE HVAC CONTRACTOR SHALL WARRANT ALL WORKMANSHIP AND MATERIALS FOR AND LESS RUNNING HORIZONTALLY RAY BE HANG FROM STANDARD CLEVIS ONE YEAR FROM THE DATE OF FINAL WORK ACCEPTANCE. BY OWNER. ANY HANGERS, WITH ISOLATION PAD BETWEEN PIPE &HANGER AND SPRING OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE TO ISOLATORS. .BREAKDOWN THE OWNER. THE COMPRESSOR (S) SHALL HAVE. A FIVE YEAR. WARRANTY. 19. UPON INSTALLATION OF DRYER EXHALST DUCT, BECAUSE OF FIELD 14. MOUNT ALL EQUIPMENT FOR WIND LOADS AND MOUNTING HEIGHTS AS REQUIRED BY COORDINATION DRYER EXHAUST EXCEED MANUFACTURER RECOMMENDED LENGTH LOCAL CODES. (INCLUDING ELBOWS). 15. ALL LOUVERS, GRILLS, PIPING, ETC. SHALL BE PAINTED TO MATCH SURROUNDING 20. PROVIDE PROOF OF AIR FLOW TO ALL AIR MOVING EQUIPMENT USE IN THE COLOR AND TEXTURES AS REQUIRED BY ARCHITECT. VERIFY COLOR AND TEXTURE SMOKE CONTROL SYSTEM, CURRENT SENSORS FOR ALL DIRECT DRIVE FANS WITH ARCHITECT. PAINT ALL EXPOSED MECHANICAL EQUIPMENT WITH.BENJAMIN AND SAIL SWITCHES FOR ALL. BELT DRIVING FANS. PSI. MOORE EPDXY ENAMEL 182. 21. ALL VALVES AND FITTINGS RATED TO 175 22. PROVIDE 1" VIBRATION ISOLATION PAD (NEOPRENE PAD) FOR ALL AHU AND A/C 16. ALL CUTTING, PATCHING, STRUCTURAL STEEL, WEATHER PROOFING, PAINTING, AND UNITS. WALL OPENINGS SHALL BE BY THE GENERAL CONTRACTOR: 23• SEAL ALL DUCTS, JOIN.T.S. AND SEAMS AN AN APPROVED MANNER TO INSURE 17. ALL OPENINGS IN BUILDING STRUCTURE, FOR DUCTWORK, PIPING, ETC. TO BE 1/2" AGAINST LEAKAGE. LARGER (ON ALL SIDES)THEN THE OUTSIDE DIMENSIONS. FILL VOIDS WITH FIRE 44. PROVIDE CIRCUIT SETTEES FOR ALL HEAT PUMPS (DIRECT RETURN SYSTEM RETARDANT SILICONE FOAM (I.E. CHASE -FOAM CTC PR-855 BY CHASE. TECHNOLOGY ONLY). CORP.): 25. ALL HORIZONTAL EXHAUST DUCTWORK INSIDE APARTMEN.T.S. SHALL HAVE PITCH 18. ALL STORAGE ROOMS, TOILETS, ETC. (COMMON AREAS), WILL HAVE 3/4" UNDERCUT OF 1/16" PER LINEAR FOOT TOWARD THE WALL CAP. DOORS TO PROVIDE VENTILATION REQUIRED WHEN DOOR OR TRANSFER GRILLES 26. RETURN AIR PLENUMS SHALL BE CONSTRUCTED AIR TIGHT TO AVOID AIR ARE NOT SHOWN. LEAKAGE. NO COMBUSTIBLE MATERIALS ALLOWED IN PLENUM SPACE. NO 19, ALL BEDROOMS AND BATHROOMS. (APARTMEN.T.S.), WILL HAVE 1" UNDERCUT DOORS EXHAUST DUCTWORK SHALL BE INSTALLED IN RETURN AIR PLENUMS. '.. TO PROVIDE VENTILATION REQUIRED. 20.PROVIDE FLEXIBLE DUCT CONNECTORS, RATED AS REQUIRED, TO ALL FANS, A/C UNITS, OR MECHANICAL EQUIPMENT. 21.PROVIDE MAINTENANCE AND. OPERATION MANUAL ON ALL MECHANICAL EQUIPMENT OR SYSTEMS. PROVIDE 5 SETS OF. SUBMITTALS ON ALL HVAC EQUIPMENT. y�� /� ADDITIONAL COMPLIANCE NOTES: SUBMITTALS SHALL HAVE.A SUMMARY. SHEET SHOWING ALL SCHEDULED INFORMATION. 22, CONTRACTOR TO PROVIDE A COMPLETE SET OF SHOP DRAWINGS FOR ALL DUCT 1. THESE ENGINEERING DOCUMEN.T.S. AND THE RESULTING INSTALLATION OF THE '.. LAYOUT INCLUDING APARTMENT. CONTRACTOR TO VERIFY FIELD CONDITIONS AND DEPICTED HVAC SYSTEMS FOR THIS PROJECT ARE INTENDED TO CONFORM TO THE NOTE ANY CONFLICT ON THE SHOP DRAWING FOR ENGINEER TO COMMENT. FOLLOWING CODES AND STANDARDS: 23. CONTRACTOR IS TO PROVIDE SHOP DRAWINGS AND SUBMITTALS BASED ON THE -' APPROVED SET OF DRAWINGS. ANY DEVIATION FROM THE ORIGINAL DESIGN MUST BE • FLORIDA BUILDING CODE 6TH EDITION (2017) BROUGHT LP TO THE .ATTENTION OF THE ENGINEER OF RECORD FOR REVIEW AND FLORIDA BUILDING CODE RESIDENTIAL 6TH EDITION (2017) COMMEN.T.S.. . FLORIDA BUILDING CODE MECHANICAL 6TH EDITION (2017) • FLORIDA ENERGY CONSERVATION CODE 6TH EDITION (2017) . FLORIDA FIRE CODE 61-KMATERIALS _ • ACCA MANUALPREVENTIOND 2009 - R SIIDENTALEDITION DUCT SYSTEMS • ASHRAE 2009 FUNDAMENTALS HANDBOOK A. AIR CONDITIONING RIGID DUCTWORK SHALL BE CONSTRUCTED OF - H THICK . ASHRAE STD 62.1 2010 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY NAIMA AH116-2009 FIBROUS GLASS DUCT CONSTRUCTION STANDARDS OR EQUAL. DUCT FIBERGLASS DUCT BOARD AS MANUFACTURED BY E , NFPA 90A - STANDARD FOR AIR CONDITIONING AND VENTILATION SYSTEMS TERTAINTEED WORK TO BE FABRICATED AND INSTALLED PER LATEST SMACNA STANDARDS. NFPA 101 - LIFE SAFETY CODE SMACNA 2005 HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE B. FLEXIBLE DUCTWORK SHALL BE CLASS I AIR DUCT, U.L. 181 LISTED AS SMACNA 010 FIBROUS GLASS CONSTRUCTION STANDARDS MANUFACTURED BY ATCO FLEXAIRE OR APPROVED EQUAL AND OF R=6.0. UL181 2005 FACTORY MADE AIR DUCTS AND AIR CONNECTORS INSTALL PER LATEST S.M.A.C.N.A. STANDARDS AND MANUFACTURER'S RECOMMENDATIONS. FLEXIBLE DUCTS SHALL BE CONFIGURED AND SUPPORTED SO IF WORK AS LAID OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS AS TO PREVENT THE USE OF EXCESS DUCT MATERIAL, PREVENT DUCT WITH THE LISTED CODES AND STANDARDS, THE CONTRACTOR SHALL REPORT IN DISLOCATION OR DAMAGE, AND PREVENT THE CONSTRICTION OF THE DUCT BELOW WRITING TO THE ARCHITECT/ENGINEER BEFORE SUBMITTING A BID. THE THE RATED DUCT DIAMETER IN ACCORDANCE WITH THE FOLLOWING ARCHITECT/ENGINEER WILL THEN ISSUE INSTRUCTIONS AS HOW TO PROCEED. REQUIREMENTS: 1. DUCTS SHALL BE INSTALLED FULLY EXTENDED. DUCT SHALL NOT EXCEED 2. ALL EQUIPMENT IS TO BE INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS, 8'-0" IN LENGTH THE TOTAL EXTENDED LENGTH OF DUCT MATERIAL SHALL SPECIFICATIONS, AND RECOMMENDATIONS FOR SAFE AND EFFICIENT OPERATIONS. ALL NOT EXCEED 5 PERCENT OF THE MINIMUM REQUIRED LENGTH FOR THAT MANUFACTURER OPERATION AND MAINTENANCE GUIDES SHALL BE ISSUED TO THE RUN. 2. BENDS SHALL MAINTAIN A CENTERLINE RADIUS OF NOT LESS THAN ONE BUILDING OPERATOR AFTER SUCCESSFUL COMPLETION OF MAINTENANCE AND/OR DUCT DIAMETER. BUILDING OPERATORS. PROCEDURES TRAINING OF THE B G PREVENTATIVE MAINTENANCE PR S 3. TERMINAL DEVICES SHALL BE SUPPORTED INDEPENDENTLY OF THE FLEXIBLE DUCT. 3. DESIGN CRITERIA INCLUDES BUT NOT LIMITED TO: 4. HORIZONTAL DUCT SHALL BE SUPPORTED AT INTERVALS NOT GREATER THAN • INSIDE DESIGN CONDITIONS - 75'F/63'F COOLING, 70'F HEATING 5 FEET. DUCT. SAG BETWEEN SUPPORTS SHALL NOT EXCEED 1./2 INCH PER. . .OUTSIDE DESIGN CONDITIONS - 91°F/79'F FOOT OF LENGTH. SUPPORTS SHALL BE PROVIDED WITHIN 1.5 FEET OF • EXTERIOR CBS WALL INSULATION - FI-FOIL R=4.1 INTERMEDIATE FITTINGS AND BETWEEN INTERMEDIATE FITTINGS AND BENDS. ATTIC BATT INSULATION - R=30.0 CEILING JOISTS AND RIGID DUCT OR EQUIPMENT MAY BE CONSIDERED TO BE • SLAB ON GRADE INSULATION - NONE SUPPORTS. • ELEVATED FLOOR OVER UNCONDITIONED SPACE - NONE 5. HANGERS, SADDLES AND OTHER SUPPORTS SHALL MEET THE DUCT g • GARAGE PARTITION - WOOD FRAME PARTITION R-11 MANUFACTURER'S RECOMMENDATIONS AND SHALL BE NOT LESS THAN 1-1/2 A EXTERIOR GLAZED FENESTRATION SUMMER DAYTIME .U.VALUE = 1.07, SHGC=0.35 INCHES WIDE AND SHALL BE OF SUFFICIENT WIDTH TO PREVENT RESTRICTION OF THE INTERNAL DUCT DIAMETER. C. TOILET EXHAUST DUCTWORK SHALL BE GALVANIZED SHEET METAL DUCT INSTALLED IN ACCORDANCE WITH THE LATEST SMACNA AND ASHRAE STANDARDS AND LEGEND MANUFACTURERS RECOMMENDATIONS. D. DRYER EXHAUST DUCTWORK SHALL BE 26 GAGE ROUND SHEET METAL SNAP LOCK PIPE OR EQUAL. DRYER EXHAUST DUCTWORK SHALL BE INSTALLED IN STRAIGHT RIGID DUCTWORK, R=6.0 LINE FASHION AND IN COORDINATION WITH OTHER TRADES IN ORDER TO AVOID TRAPS AND DIPS IN THE DUCTWORK. E. DRYER EXHAUST DUCTWORK SHALL BE AS FOLLOWS: FLEXIBLE DUCT, CLASS I, R=6.0 1. 4.0, AND CONSTRUCTED OF 26 GAGE GALVANIZED SHEET METAL AND OF SMOOTH INTERIOR FINISH. 2. SUPPORTED EVERY 4FT. 3. INSERT END OF THE DUCT SHALL EXTEND INTO THE ADJOINING END. RETURN AIR REGISTER/GRILLE 4. NO SCREWS OR FASTENERS THAT PROTRUDE INTO THE SIDE OF THE DUCT ARE ALLOWED. 5. THE EQUIVALENT LENGTH OF DUCT SHALL BE IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6FT OF THE CURVED BLADE CEILING GRILLE - 1.2, OR 4-WAY. EXHAUST DUCT CONNECTION. AIR GUIDE MODEL CB WITH OPPOSED BLADE DAMPER. 6. TRANSITION DUCTS USED TO CONNECT THE DRYER TO THE EXHAUST DUCT ( OR EQUAL) SHALL BE A SINGLE LENGTH THAT IS LISTED AND LABELED IN ACCORDANCE WITH UL 2158A. TRANSITION DUCTS SHALL BE A MAXIMUM OF 8FT LONG RETURN AIR GRILLE - AIR GUIDE MODEL RH (OR AND SHALL NOT BE CONCEALED WITHIN CONSTRUCTION. TRANSITION DUCT TO Z EQUAL). BE DRYER FLEX DRYER EXHAUST DUCT BY IN -OVATE DRYER PRODUCTS OR } EQUAL. DRYER. BOX AND TRANSITION DUCT TO BE PURCHASED SEPARATELY FROM APPLIANCE. MOTORIZED CONTROL DAMPER.W/ACCESS PANEL. 7. ALL FLOOR SLAB .PENETRATIONS OF THE DRYER DUCT SHALL BE SEALED DAMPER OPEN WHEN AHU IS ON; CLOSED WHEN WITH APPROVED FIRE -STOPPING MATERIAL. AHU IS OFF. F. ALL AIR DISTRIBUTION DEVICES SHALL BE OF ALUMINUM CONSTRUCTION, PAINT WITH WHITE ENAMEL (COORDINATE WITH ARCHITECT) MANUFACTURED. BY TITUS OR O SINGLE STAGE HEAT/COOL PROGRAMMABLE APPROVED. THERMOSTAT MOUNTED. AT 46" A.F.F.. G. FILTERS SHALL BE OF DISPOSABLE TYPE AND HAVE CLEAN PRESSURE DROP OF - REFRIGERANT PIPING -SEE SPLIT SYSTEM SCHEDULE 0.15" PROVIDE TWO SETS, ONE DURING CONSTRUCTION AND ONE FOR USE _ FOR SIZES AFTER OCCUPANCY. H. COUNTERBALANCED BACKDRAFT DAMPERS SHALL BE HEAVY DUTY EXTRUDED ALUMINUM RUSKIN MODEL CBD2 OR APPROVED EQUAL. 1. ALL DUCT ACCESS DOORS TO BE SMACNA STANDARD LOW LEAKAGE DOUBLE SKIN ABBREVIATIONS (NOT ALL APPLY) MANUFACTURED BY RUSKIN. MINIMUM SIZE 10"x10". J. ALL SUPPLY, RETURN, AND EXHAUST DUCT WORK SHALL BE SEALED TIGHT PER SMACNA STANDARDS. A/C AIR CONDITIONING UNIT FB FLOW BAR DIFFUSER K. FIRE DAMPERS SHALL BE STYLE "B", U.L. 555 LISTED, 265 F FUSIBLE. LINK AD ACCESS DOOR FLD FULL LOUVER DOOR RUSKIN MODEL DIBD20 OR APPROVED EQUAL AND SHALL BE INSTALLED IN AFF ABOVE FINISHED FLOOR GD GRAVITY DAMPER ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. AHU AIR HANDLING UNIT MVO MANUAL VOLUME DAMPER AP ACCESS PANEL MCD MOTORIZED CONTROL DAMPER BOO BACK DRAFT DAMPER OBD OPPOSED. BLADE DAMPER BFC BELOW FINISHED CEILING OAI 'OUTSIDE AIR INTAKE CFM CUBIC FEET PER MINUTE DAL OUTSIDE AIR LOUVER CG CEILING GRILLE RAG RETURN AIR .GRILLE CLG CEILING SO SMOKE DETECTOR. CM CEILING MOUNTED SF. SUPPLY FAN CU CONDENSING UNIT SR SIDEWALL REGISTER DG DOOR GRILLE TG TRANSFER GRILLE EF EXHAUST FAN TV TURNING VANES EG EXHAUST GRILLE UD UNDERCUT DOOR EAL EXHAUST AIR LOUVER WM WALL MOUNTED ER EXHAUST REGISTER WMS WIRE MESH SCREEN MIN. 2"+0 OF FLEX DUCT RIGID BOARD' FIBERGLASS PLENUM BOX; `\ MIN, 2"+0 OF FLEX DUCT i SIZE AS REQUIRED CUT PLENUM BOX PER GRILLE REQUIREMENT, (VERT OR HORZ).SEE PLANS FOR MODELS & SIZES ALL FLEX DUCT TO BE FULL CIRCLE INTO GRILLE BOOTS (TYPICAL) FLEX-DUCT/PLENUM BOX DETAIL N.T.S. LANAI j DINING I IIII L Ill j 8x8 CG-4W 150 CFM I 1 16)t6 16x16 RAGV �V RAG FAMILY 6"0 ROOM I OWNERS + SUITE 8x8 (G-4yW 1.5D CFM 6"0 - - �- 8 - - I000 CG-1W INSTALLATION OF CONDENSING UNIT SHALL COMPLY WITH FBC-2017 ISOMODE PADS 4" CONCRETE PAD FASTEN COND UNIT BASE PAN TO 4" CONC, PAD WITH (4) 1/4" TAPCON CONCRETE SCREWS. SCREWS TO PENETRATE CONCRETE 1.5" MINIMUM, PLACE SCREWS AS INDICATED IN THE BASE PAN. -- I'MN LINES 6e, •° d4 m, FINISHED GRADE am°° o a a >\ K >\ K ice\ O O - O O CONDENSING UNIT FASTENING DETAIL N.T.S. 1 1/2", 26 GAGE HANGER BAND CLAMP WITH BAND STRAP 1" MIN. I 5'-0" p1 1/2 HANGER BAND CLAMP II WITH WIRE IS OPTIONAL. FLEXIBLE DUCT 24"0 MAX. TO BE INSTALLED IN ACCORDANCE WJMANUFACTURES INSTALLATION INST UCTION. USE DUCT SEALER & BANDING DEVICE. FLEXIBLE DUCT SUPPORT N.T.S. SPLIT SYSTEM SCHEDULE_ UNIT NUMBER AHU-1 MANUFACTURER RHEEM MODEL NUMBER RHIT3624STANJA CABINET VERTICAL Z TOTAL AIRFLOW (dm) / EXT. STATIC PRESSURE (we) 1200/0.25 O/A CFM 60 E.A.T. (db/wb -F) 76/63.8 Z SENSIBLE COOLING CAPACITY (mbh) 26.1 J TOTAL COOLING CAPACITY (mbh) 34.0 Z BLOWER MOTOR HP / F.L.A, 1/2 / 2.7 VOLTAGE 230-1-60 UNIT WEIGHT 125 MATCHING CONDENSING UNIT CU-1 APPROXIMATE SIZE (LxWxH) (in) 22 x 244 x 35 ELECTRIC HEAT ER KW 9.6 CAPACITY (mbh) 32.7 CU NUMBER CU-1 MANUFACTURER RHEEM MODEL NUMBER RA1436AJINA NOMINAL TONS 3.0 CONDENSER AIR ENTERING TEMP ('F) 95'F 1- No. OF COMPRESSORS 1 R.L.A. ea 14.1 tR L.R.A. ea 77 Z No. OF CONDENSER FANS 1 (n F.L.A. ea 0.8 WVOLTAGE 230-1-60 0 CU MAX BREAKER SIZE 30 ZOSYSTEM SEER 15.0 U LIQUID LINE' (in) 3/8 SUCTION LINE (in) 7/8 UNIT WEIGHT (lbs) 171 AREA SERVED SEE DWG. ACCESSORIES: 1. BUILT IN CONDENSATE PAN FLOAT SWITCH. 2. FACTORY PROGRAMMABLE THERMOSTAT WITH COLOR TOUCH SCREEN. 3. NON COMBUSTIBLE FLOOR STAND FOR AHU. 4. 3/4" SLIP ON ARMAFLEX INSULATION FOR ENTIRE LENGTH OF RE MECHANICAL VENTILATION CALCULATION: 3 BEDROOMS X (1 PERSON/BEDROOM + 1) X 15 CFM/PERSON = 60 CFM FAN SCHEDULE FAN No MFG MODEL No FAN TYPE 1 CFM _._,,. S.P. FAN RPM MOTOR HP VOLTS DRIVE SpNES LOCATION SERVICE ACCESSORIES -1 EFFXH GREENHECK SPA CEILING FAN 50 0.25 850 13W 120-1-k1, DIRECT I 0.30 SEE DWS BATH 1,2 ACCESSORIES:'' A. BACK DRAFI B, DECORATIVE NGE PANTRY 1000 12"0 REF. UNES DOhN IN LINE COVER EWH -, / GU - AHU-1 - (I,400cfm) LAUNDRY 12x12 DOOR 4"e GRILLE 6x6 CGS W ` 4"0 O/A INTAKE 1 �� UP TO ROOF CAP 50 8"0 PANEL 'A' DRYER E _ 5"0' ATTIC I L FOYER L_ ACCSS - J s -a" c�G. CL 12xl RAG DRYER EXH' DRYER 8"0 I WALL CAP >= BOX� 1 6"0 2 CAR GARAGE 8x8 CG-1W 150 CFM I 1 BEDROOM 2 -_ { I -- i I�I it PORCH VAC FLOOR PLAN SCALE: 1/4" = 1'-0" ,i- ���� = • mill ®I11111111111/�� � �/���I1011ylllilllllt�lilll�l� �� i • � C _ 01`11011i11111111111Vh,1011111111N1111 `` - �® „q . \0\111M111 dUlllllllllllltlllllil' -..T�- ' ; 4i HI41111N�•1' ����`� o s' �IIIltillllf/IIq�'' i ��®/ � _ ���llillllllllllll „ �/IIIOOIIIIIIIIUIIIIIIIEalllllllllllillSII011110111 �IIIIIIIIIIU011 _ ' ' ®oouoeau000eone�l„ � Ind METER & DISC DAMPER CEILING GRILLE PLENUM ATTACHMENT PER SMACNA FIBROUS GLASS DUCT FIG 2-25 CONSTRUCTION STANDARDS. PAGE 2.14 ( ) FIBROUS GLASS PLENUM DUCT -DISCONNECT 2}" SQ. WASHERS SWITCH 12" MAX O.C. 22 GAUGE S.M. AUX. OVERFLOW MIN. 2 PER SIDE 1 %3" COLLAR MICRO -SWITCH If 1Ox1}" SHEET o AHU METAL SCREWS GLASS FABRIC & MASTIC CLOSURE OR UL LISTED SUPPLY AIR PRESSURE SENSITIVE ALUM. DISCHARGE TAPE (SEE EXCEPTIONS) FLANGE EQUIP. TOP \ SCREW, POP RIVET OR VIBRATION SPOT WELD TO EQUIP. ISOLATION FLANGE PADS FILTER - RACK FLOOR AHU PLENUM DUCT ATTACHMENT N.T.S. REFRIG. LINES UP TO CU AT ROOF METAL STAND CODE COMPL ST. LUCIE CO' BOCC revisions no. date designed --- drawn LTH checked SBD date 10/24/19 (PERMIT SET) scale 1/4" = V-0" (U.O.N.) job no. 190627_SF-21.lh FILE COPY \00\\0111111//// �\C NS� No. 43414 A STATE OF � F � \ drawing JOB NUMBER: 20011 21 34 N.W. 168"' Street North Miami Beach, FL 33169 Tel.: (305) 653-0212 E-Mail: AlbertS@fesinc.biz Albert Shub, P.E., LEED AP P.E.#: 0043414 - Mechanical C.O.A.: EB00038C sheet ® (; W Q L_ W W W 0 N L d W W Ill- _ GV ® LL0 -0 AC-1