Loading...
HomeMy WebLinkAboutCertification for Design Load Compliance'q or . Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Single Family Model Residence CAN a Project Address: 5412 Deleon Avenue Permit #: Occupancy Type: R-3 Construction Type: IV INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. �pp� ��� mq • Submit (2) copies for residential, (3) copies for commercial wit ii>�i FfIIPeafiifing idv6lving the following: o New Residences (single or multi -family) CODE COMP I A o Residential Addition S-r. LUCI C0"j o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected.and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: ' (complete all that apply) 1. DESIGN CODE: Florida Building Code Sixth Edition with 2017 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: I X 1 II III_._ )IV Exposure Category: B X C D 4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: ft 5. Mean Roof Height 13.416 ft Roof Pitch: 4 :12 Parapet: N/A ft 6. Components & Cladding Design,Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): an N/A ,one g. N/A Zone N/A one 4. 41.50/45.01 �5.03/ 42.63 Garage: 35.03/-42.63 7. Design Loads: Floor:100 TTL PSF Roof/Dead:15 TIC PSF Roof/Live: 30 TC Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs. 40 PSF Fence N/A PSF Railings: 200 CL PSF Q Were Shear Walls Considered For Structure?-X--Yes Not Applicable Explain Why Not: . 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 7:t?. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Scott Disher Signature, Date,.and Seal Print Name Cert # & Co. Cert Auth. AR 11586 Architectural Studio, Inc., Palm Beach Gardens, FL Company Name & Address Revised 12/07/2018