Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-201.7 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SINGLE FAMILY HOME Builder Name: Street: 5412 DELEON AVE Permit Office: FORT PIERCE CITY City, State; Zip: FORT PIERCE, FL, 34951 Permit Number: Owner: 21ST STREET, LLC Jurisdiction: 661100 Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1594.4 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1516.70 ftz b. Concrete Block -.Int Insul, Adjacent R=11.0 77.78 ftz 3. Number of units, if multiple family 1 c. N/A R= ft� 4. Number of Bedrooms 3 d. N/A R= ftz 10. Ceiling Types (1521.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1521.00 ftz 6. Conditioned floor area above grade (ftz) 1521 b. N/A R= ftz Conditioned floor area below.grade (ftz) 0 c. N/A R= - ftZ 11. Ducts R ftz 7. Windows(198.1 sqft.) Description Area a. Sup: Foyer and Hall, Ret: Foyer and Hall, AH: Foy4.2 117.5 a. U-Factor: Sgl, U=1.07 198.06 ftZ SHGC: SHGC=0.35 b. U-Factor: N/A ftz 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 34.0 SEER:15.00 c. U-Factor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Strip Heat 32.8 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 4.322 ft. Area Weighted Average 'SHGC: 0.350 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1521.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1521.00 ftz b. Conservation features b. N/A R= ftZ None c. N/A R= ftz 15. Credits Pstat Total Proposed Modified Loads: 51.24 Glass/Floor Area: 0.130 L+S PASS Total Baseline Loads: 51.50 /'1�7�7 J hereby certify that the plans and specifications covered by Review of the plans and , tUE S3',q?, this calculation are in compliance with the Florida Energy specifications covered by this .y0� . _ - ` 0�, Code. calculation indicates compliance �,5 NG with the Florida Energy Code. PREPARED BY: � Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 0 ; * ° I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COD WE T¢� OWNER/AGENT: BUILDING OFFICIAL: DATE: 5- A ut-D DATE: r Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 5/20/2020 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT ' Title: SINGLE FAMILY HOME Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1521 Lot # Owner Name: 21 ST STREET, LLC Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: Rotate Angle: 90 Street: 5412 DELEON AVE Permit Office: FORT PIERCE CITY Cross Ventilation: County: St. Lucie Jurisdiction: 661100 Whole House Fan: City, State, Zip: FORT PIERCE, Family Type: Single-family FL , 34951 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 1521 14190.9 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Family Room 383 3573.4 No 1 0 1 Yes Yes Yes 2 Owner Suite 194 1810 No 2 1 1 Yes Yes Yes 3 Owner Suite Bath C 144 1343.5 No 0 0 1 Yes Yes Yes 4 Kitchen 202 1884.7 Yes 0 0 1 Yes Yes Yes 5 Bedroom 2 128 1194.2 No 1 1 1 Yes Yes Yes 6 Foyer and Hall 230 2145.9 No 0 0 1 Yes Yes Yes 7 Bedroom 3 150 1399.5 No 1 1 1 Yes Yes Yes 8 Laundry Room 38 354.5 No 0 0 1 Yes Yes Yes 9 Bathroom 2 52 485.2 No 0 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio - Family Room 78.33 ft 0 383 ft2 ____ 0 0 1 2 Slab -On -Grade Edge Insulatio Owner Suite 55.42 ft 0 194 ft2 ---- 0 0 1 3 Slab -On -Grade Edge Insulatio Owner Suite Bath48.67 ft 0 144 ft2 ---- 0 0 1 4 Slab -On -Grade Edge Insulatio Kitchen 62.75 ft 0 202 ft2 ---- 0 0 1 5 Slab -On -Grade Edge Insulatio Bedroom 2 46.33 ft 0 r 128 ft2 ---- 0 0 1 6 Slab -On -Grade Edge Insulatio Foyer and Hall 88.67 ft 0 230 ft2 ____ 0 0 1 7 Slab -On -Grade Edge Insulatio Bedroom 3 54.33 ft 0 150 ft2 ---- 0 0 1 5/20/2020 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio Laundry Room 37.65 ft 0 38 ft2 ---- 0 0 1 9 Slab -On -Grade Edge Insulatio Bathroom 2 30.58 ft 0 52 ft2 ---- 0 0 1 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or shed Barrel tile 1603 ft2 252 ft2 Medium N 0.75 No 0.9 No 0.1 18.4 ATTIC V # . Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1521 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Family Room 30 Blown 383 ft2 0.08 Wood 2 Under Attic (Vented) Owner Suite 30 Blown 194 ft2 0.08 Wood 3 Under Attic (Vented) Owner Suite Bath 30 Blown 144 ft2 0.08 Wood 4 Under Attic (Vented) Kitchen 30 Blown 202 ft2 0.08 Wood 5 Under Attic (Vented) Foyer and Hall 30 Blown 230 ft2 0.08 Wood 6 Under Attic (Vented) Bedroom 3 30 Blown 150 ft2 0.08 Wood 7 Under Attic (Vented) Bedroom 2 30 Blown 128 ft2 0.08 Wood 8 Under Attic (Vented) Laundry Room 30 Blown 38 ft2 0.08 Wood 9 Under. Attic (Vented) Bathroom 2 30 Blown 52 ft2 0.08 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below SpaceFt In Ft In Area 13-Vallie Ahqnr 1 E=>S Exterior Concrete Block - Int Insfbmily Room 4.1 20 8 9 4 192.9 ft2 0 0.5 0 2 S=>VV Exterior Concrete Block - Int Instibmily Room 4.1 19 10 9 4 185.1 ft2 0 0.5 0 3 S=>W Exterior Concrete Block - Int Insul Kitchen 4.1 9 4 9 4 87.1 ft2 0 0.75 0 4 S=>W Exterior Concrete Block - Int InsuBedroom 3 4.1 11 4 9 4 105.8 ft2 0 0.75 0 5 W=>N Exterior Concrete Block - Int InsEbyer and Hal 4.1 5 0 9 4 46.7 ft2 0 0.75 0 6 W=>N Exterior Concrete Block - Int InsuBedroom 2 4.1 11 0 9 4 102.7 ft2 0 0.75 0 7 N=>E Exterior ConcreteBlock- Int InsuBedroom 2 4.1 13 11 9 4 129.9 ft2 0 0.75 0 8 N=>E Exterior Concrete Block - Int Insddaundry Roo 4.1 6 3 9 4 58.3 ft2 0 0.75 0 9 N=>E Exterior Concrete Block - Int InsOwner Suite 4.1 14 7 9 4 136.1 ft2 0 0.75 0 10 N=>E _Exterior Concrete Block - Int lnsLC)Wner Suite 4.1 15 6 9 4 144.7 ft2 0 0.5 0 _1 1 E=>S Exterior Concrete Block - Int lnstIDWner Suite 4.1 14 4 9 4 133.8 ft2 0 0.5 0 12 N=>E Exterior Concrete Block --Int InsuBathroom 2 4.1 5 5 9 4 50.6 ft2 0 0.75 0 13 N=>E Exterior Concrete Block - Int Insfi bmily Room 4.1 8 0 9 4 74.7 ft2 0 0.75 0 14 S=>W Exterior Concrete Block - Int InsuBedroom 2 4.1 7 4 9 4 68.4 ft2 0 0.75 0 15 W=>N Garage Concrete Block;. Int InsuBedroom 3 11 8 4 9 4 77.8 ft2 0 0.75 0 5/20/2020 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 W=>N Wood Foyer and Hal None .46 3 8 24 ftz WINDOWS Orientation shown is the entered orientation => changed to Worst Case. # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp" Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 6 7 8 9 E=>S 1 Metal S=>W 2 Metal S=>W 4 Metal W=>N 6 Metal N=>E 8 Metal N=>E 12 . Metal N=>E 9 Metal N=>E 10 Metal N=>E 13 Metal Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes 1.07 0.35 N 1.07 0.35 N 1.07 0.35 N 1.07 0.35 N 1.07 0.35 N 1.07 0.35 N 1.07 0.35 N 1.07 0.35 N 1.07 0.35 N 49.3 ftZ 1 ft 4 in 0 ft 7 in �16.4 ft' 1 ft 4 in 0 ft 7 in 16.4 ft' 1 ft 4 in 0 ft 7 in :19.5 ftZ 1 ft 4 in 0 ft 7 in 12.8 ft' 1 ft 4 in 0 ft 7 in 12.8 ftZ 1 ft 4 in 0 ft 7 in :6.2 ft2 1 ft 4 in 0 ft 7 in 32.0 ftz 8 ft 0 in 0 ft 7 in 32.4 ftz 13 ft 0 in 0 ft 7 in Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter -Avg. Wall Height Exposed Wall Insulation 1 _ 378 ftZ 378 ftZ 82 ft 9.33 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000296 1182.6 64.92 122.1 .1092 5 - HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 32.75 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing[ SEER: 15 34 kBtu/hr 1200 cfm 0.825 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap . Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 40 gal 120 deg None 5/20/2020 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Foyer and Hal 4.2 117.5 ft Foyer and Hal39.9 ft2 Prop. Leak Free Foyer and --- cfm 45.6 cfm 0.03 0.65 1 1- TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb Mar HeatinJan Feb � Mar Apr Apr Jul May I I Jun Jul Ma X Jun ri Aug Au Se Sep [ ] Oct Nov [ ] Oct Nov Dec Dec Ventin Jan Feb X Mar L [ A r [ Ma Jun Jul L [ Aug l Se [X] Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 -78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System Runtime Vent 15 0 0 0 1 - Electric Strip Heat % 1 - Central Unit MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Family Room Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Owner Suite Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Owner Suite Bath C Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Kitchen Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Foyer and Hall Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Laundry Room Default(8 Ibs/s .ft. 0 ft2 O ft 0.3 Bathroom 2 5/20/2020 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 . 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition .. 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 4.2 2. Single-family or multiple -family 2. Single-family b) Return ducts R 4.2 c) AHU location Foyer and Hall 3. No -of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.0 a).Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) .Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1521 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.070 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.350 c) Area 7c. 198.1 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 10131. 10132. 11.0 11 a. 30.0 11 b. 1111c. 11d. No 14. Heating system: Capacity 32.8 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e)-Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. . Builder Signature: Address of New Home: 5412 DELEON AVE City/FL Zip: FORT PIERCE, FL 34951 5/20/2020 9:41:15 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 • 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: SINGLE FAMILY HOME Builder Name: Street: 5412 DELEON AVE Permit Office: FORT PIERCE CITY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: • Y U Owner: 21ST STREET, LLC Jurisdiction: 661100 W DesignLocation: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. WAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 5/20/2020 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Duct Leakage Test Report Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: 661100 I Permit #: Builder: Community: Lot: NA Address: 5412 DELEON AVE City: FORT PIERCE State: FL Zip: 34951 System 1 cfm25 System 2 cfm25 System 3 cfm25 Sum of any cfm25 Total of all cfm25 1521 = Qn Total of all Total Conditioned systems Square Footage PASS [:]FAIL an the Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes. Company Name: Phone: I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above, either the Prescriptive Method or Performance Method. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 5/20/2020 9:41:47 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Air System Sizing Summary for AHU & CU-1 Project Name: Single Family Home 05/20/2020 Prepared by: FES, Inc 09:02AM Air System Information Air System Name: ............................................... AHU & CU-1 Air System Type: ....................................... Single Zone CAV Sizing Calculation Information Calculation Months: ............................................... Jan to Dec Central Cooling Coil Sizing Data Total coil load:......-----:-------------------------------------------------------------2.8 Tons Total coil load: ........................................................................ 33.8 MBH Sensible coil load: ................................................................30.9 MBH Coil airflow:........................................... ................................. 402 CFM Sensible heat ratio: .......... ....................... ......................... 0.914 Area per unit load: ------------------------- ------------------------------------- 508.1 sgft/Ton Load per unit area: --------------------------------------------------------------- 23.6 BTU/(hr-sgft) Central Heating Coil Sizing Data Maxcoil load: .......................................................................... MBH Coilairflow: ...................................... --------------------------------------1402 CFM Load per unit area: .................................................................. 9.9 BTU/(hr-sgft) Supply Fan Sizing Data Actual max airflow: ....-_.------------------------------------------------------ 1402 CFM Standard airflow: .................................................................. 1401 CFM Actual max airflow per unit area: ..................................... 0.98 CFM/sqft Outdoor Ventilation Air Data Design airflow-------------------------------- ........................................ CFM Airflow per unit floor area: ................... .............................. 0.00 CFM/sqft Space Sizing Data Number of zones: ...... ............. ......................-................. I Floor Area-- ----- --- ------------------------- . -- .............-----------1432.3 sqft Location: ------------ .. West Palm Beach, Florida Calculation method: ........................... Radiant Time Series Load occurs at:---.........................................................Jul 1500 CA DB / WB:................................................................ 92.0/79.0 F Entering DB / WB:.......................... ........--------------75.5/62.3 F Leaving DB f WB: ----- . ...................-------......--.......55.0/53.8 F CoilADP---------------------------------------------------- --- --- ---- ----- --------52.7 F Bypass Factor: ............................... ------------------------------------ 0.100 ResultingRH---------------------------------------------- _............................ 48 % Design supply temp-............. -.............................................. 55.0 F Load occurs at: .....................---- -- . ----------............. Des Htg Ent DB / Lvg DB: -------- ................................................ 69.9179.2 F Fan motor BHP: --------------------------------------------------------------------- 0.41 BHP Fan motor kW----..................................................................... 0.30 kW Fanstatic------------------------------------........... ..............----------1.00 in wg Airflow per person: Space Name .:. - ., Maximum Cooling Sensible -:MBH • .-Design Airflow...,;"' "•CFM'.. Time of Peak• .." .Load „ , Maximum ,' Heating Load:MBH Space Floor Area sqft Space 'CFM/sgft Bath 2 1.0 46 Jul 1600 0.7 52.0 0.88 Bedroom # 2 3.6 166 Jul 1700 1.9 119.3 1.39 Bedroom # 3 2.9 135 Oct 1400 1.5 123.0 1.10 Family Room / Kitchen 8.7 405 Jul 1500 5.5 569.0 0.71 Gallery 3.7 173 Jul 1600 1.3 220.0 0.79 Laundry 2.3 105 Jun 1600 0.6 38.0 2.77 Owner Bath 0:8 38 Jul 1600 0.6 46.0 0.83 Owner Suite 6.9 321 Jul 1500 2.7 194.0 1.66 Owner WIC 0.6 27 Jul 1600 0.31 46.01 0.58 WIC 0.11 61 Jul1600 0.11 25.0 0.26 Zone .- - ,. °. 30.3 ., - 1402 '` Juf1500 , 15.3 :1432.3 • , 0.98 Note: Table contains data for all spaces controlled by a single thermostat: Space sizing basis: .................. Peak space load Zone sizing basis: ..................... .-Peak zone load S. Q':' ��GEIUSF •:�� * No. 43414 �= STATE OF CFM/person Block Load 4.16 Page 1 of 2