HomeMy WebLinkAboutEnergy CodeFORM R405-201.7
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: SINGLE FAMILY HOME
Builder Name:
Street: 5412 DELEON AVE
Permit Office: FORT PIERCE CITY
City, State; Zip: FORT PIERCE, FL, 34951
Permit Number:
Owner: 21ST STREET, LLC
Jurisdiction: 661100
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1594.4 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1516.70 ftz
b. Concrete Block -.Int Insul, Adjacent
R=11.0 77.78 ftz
3. Number of units, if multiple family 1
c. N/A
R= ft�
4. Number of Bedrooms 3
d. N/A
R= ftz
10. Ceiling Types (1521.0 sqft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1521.00 ftz
6. Conditioned floor area above grade (ftz) 1521
b. N/A
R= ftz
Conditioned floor area below.grade (ftz) 0
c. N/A
R= - ftZ
11. Ducts
R ftz
7. Windows(198.1 sqft.) Description Area
a. Sup: Foyer and Hall, Ret: Foyer and Hall, AH: Foy4.2 117.5
a. U-Factor: Sgl, U=1.07 198.06 ftZ
SHGC: SHGC=0.35
b. U-Factor: N/A ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
34.0 SEER:15.00
c. U-Factor: N/A ftz
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftz
a. Electric Strip Heat
32.8 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 4.322 ft.
Area Weighted Average 'SHGC: 0.350
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1521.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1521.00 ftz
b. Conservation features
b. N/A R= ftZ
None
c. N/A R= ftz
15. Credits
Pstat
Total Proposed Modified Loads: 51.24
Glass/Floor Area: 0.130
L+S
PASS
Total Baseline Loads: 51.50
/'1�7�7
J hereby certify that the plans and specifications covered by
Review of the plans and
, tUE S3',q?,
this calculation are in compliance with the Florida Energy
specifications covered by this
.y0� . _ - ` 0�,
Code.
calculation indicates compliance
�,5 NG
with the Florida Energy Code.
PREPARED BY: �
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
0 ;
* °
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
COD WE T¢�
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: 5- A ut-D
DATE:
r
Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
5/20/2020 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
' Title: SINGLE FAMILY HOME Bedrooms: 3
Address Type:
Street Address
Building Type: User Conditioned Area: 1521
Lot #
Owner Name: 21 ST STREET, LLC Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: Yes
PlatBook:
Builder Name: Rotate Angle: 90
Street:
5412 DELEON AVE
Permit Office: FORT PIERCE CITY Cross Ventilation:
County:
St. Lucie
Jurisdiction: 661100 Whole House Fan:
City, State, Zip:
FORT PIERCE,
Family Type: Single-family
FL , 34951
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Block1 1521 14190.9
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 Family Room 383 3573.4 No 1
0
1 Yes
Yes
Yes
2 Owner Suite 194 1810 No 2
1
1 Yes
Yes
Yes
3 Owner Suite Bath C 144 1343.5 No 0
0
1 Yes
Yes
Yes
4 Kitchen 202 1884.7 Yes 0
0
1 Yes
Yes
Yes
5 Bedroom 2 128 1194.2 No 1
1
1 Yes
Yes
Yes
6 Foyer and Hall 230 2145.9 No 0
0
1 Yes
Yes
Yes
7 Bedroom 3 150 1399.5 No 1
1
1 Yes
Yes
Yes
8 Laundry Room 38 354.5 No 0
0
1 Yes
Yes
Yes
9 Bathroom 2 52 485.2 No 0
0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio - Family Room 78.33 ft 0
383 ft2
____
0 0
1
2 Slab -On -Grade Edge Insulatio Owner Suite 55.42 ft 0
194 ft2
----
0 0
1
3 Slab -On -Grade Edge Insulatio Owner Suite Bath48.67 ft 0
144 ft2
----
0 0
1
4 Slab -On -Grade Edge Insulatio Kitchen 62.75 ft 0
202 ft2
----
0 0
1
5 Slab -On -Grade Edge Insulatio Bedroom 2 46.33 ft 0
r
128 ft2
----
0 0
1
6 Slab -On -Grade Edge Insulatio Foyer and Hall 88.67 ft 0
230 ft2
____
0 0
1
7 Slab -On -Grade Edge Insulatio Bedroom 3 54.33 ft 0
150 ft2
----
0 0
1
5/20/2020 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
8 Slab -On -Grade Edge Insulatio Laundry Room 37.65 ft 0
38 ft2
----
0
0
1
9 Slab -On -Grade Edge Insulatio Bathroom 2 30.58 ft 0
52 ft2
----
0
0
1
ROOF
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Gable or shed Barrel tile 1603 ft2
252 ft2 Medium
N
0.75
No 0.9
No 0.1
18.4
ATTIC
V
# .
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
300
1521 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) Family Room
30
Blown
383 ft2
0.08
Wood
2
Under Attic (Vented) Owner Suite
30
Blown
194 ft2
0.08
Wood
3
Under Attic (Vented) Owner Suite Bath 30
Blown
144 ft2
0.08
Wood
4
Under Attic (Vented) Kitchen
30
Blown
202 ft2
0.08
Wood
5
Under Attic (Vented) Foyer and Hall
30
Blown
230 ft2
0.08
Wood
6
Under Attic (Vented) Bedroom 3
30
Blown
150 ft2
0.08
Wood
7
Under Attic (Vented) Bedroom 2
30
Blown
128 ft2
0.08
Wood
8
Under Attic (Vented) Laundry Room
30
Blown
38 ft2
0.08
Wood
9
Under. Attic (Vented) Bathroom 2
30
Blown
52 ft2
0.08
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
SpaceFt
In
Ft
In
Area
13-Vallie
Ahqnr
1
E=>S
Exterior Concrete Block - Int Insfbmily Room
4.1 20
8 9
4
192.9 ft2
0
0.5
0
2
S=>VV
Exterior Concrete Block - Int Instibmily Room
4.1 19
10 9
4
185.1 ft2
0
0.5
0
3
S=>W
Exterior Concrete Block - Int Insul Kitchen
4.1 9
4 9
4
87.1 ft2
0
0.75
0
4
S=>W
Exterior Concrete Block - Int InsuBedroom 3
4.1 11
4 9
4
105.8 ft2
0
0.75
0
5
W=>N
Exterior Concrete Block - Int InsEbyer and Hal
4.1 5
0 9
4
46.7 ft2
0
0.75
0
6
W=>N
Exterior Concrete Block - Int InsuBedroom 2
4.1 11
0 9
4
102.7 ft2
0
0.75
0
7
N=>E
Exterior ConcreteBlock- Int InsuBedroom 2
4.1 13
11 9
4
129.9 ft2
0
0.75
0
8
N=>E
Exterior Concrete Block - Int Insddaundry Roo
4.1 6
3 9
4
58.3 ft2
0
0.75
0
9
N=>E
Exterior Concrete Block - Int InsOwner Suite
4.1 14
7 9
4
136.1 ft2
0
0.75
0
10
N=>E
_Exterior Concrete Block - Int lnsLC)Wner Suite
4.1 15
6 9
4
144.7 ft2
0
0.5
0
_1 1
E=>S
Exterior Concrete Block - Int lnstIDWner Suite
4.1 14
4 9
4
133.8 ft2
0
0.5
0
12
N=>E
Exterior Concrete Block --Int InsuBathroom 2
4.1 5
5 9
4
50.6 ft2
0
0.75
0
13
N=>E
Exterior Concrete Block - Int Insfi bmily Room
4.1 8
0 9
4
74.7 ft2
0
0.75
0
14
S=>W
Exterior Concrete Block - Int InsuBedroom 2
4.1 7
4 9
4
68.4 ft2
0
0.75
0
15
W=>N
Garage Concrete Block;. Int InsuBedroom 3
11 8
4 9
4
77.8 ft2
0
0.75
0
5/20/2020 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DOORS
#
Ornt
Door Type Space
Storms
U-Value Width
Ft In
Height
Ft In
Area
1
W=>N
Wood Foyer and Hal None
.46 3
8
24 ftz
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
#
Wall
Ornt ID Frame
Panes NFRC
U-Factor SHGC Imp"
Overhang
Area Depth Separation Int Shade
Screening
1
2
3
4
5
6
7
8
9
E=>S 1 Metal
S=>W 2 Metal
S=>W 4 Metal
W=>N 6 Metal
N=>E 8 Metal
N=>E 12 . Metal
N=>E 9 Metal
N=>E 10 Metal
N=>E 13 Metal
Single (Tinted) Yes
Single (Tinted) Yes
Single (Tinted) Yes
Single (Tinted) Yes
Single (Tinted) Yes
Single (Tinted) Yes
Single (Tinted) Yes
Single (Tinted) Yes
Single (Tinted) Yes
1.07 0.35 N
1.07 0.35 N
1.07 0.35 N
1.07 0.35 N
1.07 0.35 N
1.07 0.35 N
1.07 0.35 N
1.07 0.35 N
1.07 0.35 N
49.3 ftZ 1 ft 4 in 0 ft 7 in
�16.4 ft' 1 ft 4 in 0 ft 7 in
16.4 ft' 1 ft 4 in 0 ft 7 in
:19.5 ftZ 1 ft 4 in 0 ft 7 in
12.8 ft' 1 ft 4 in 0 ft 7 in
12.8 ftZ 1 ft 4 in 0 ft 7 in
:6.2 ft2 1 ft 4 in 0 ft 7 in
32.0 ftz 8 ft 0 in 0 ft 7 in
32.4 ftz 13 ft 0 in 0 ft 7 in
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
None
None
None
None
None
None
None
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
-Avg. Wall Height Exposed Wall Insulation
1
_ 378 ftZ
378 ftZ
82 ft
9.33 ft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000296
1182.6 64.92 122.1 .1092
5
-
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None
COP:1
32.75 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Sing[ SEER: 15
34 kBtu/hr 1200 cfm
0.825 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType Location
EF Cap .
Use SetPnt
Conservation
1
Electric
None Garage
0.95 50 gal 40 gal 120 deg
None
5/20/2020 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System Model # Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location Area Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Foyer and Hal 4.2 117.5 ft Foyer and Hal39.9 ft2 Prop. Leak Free Foyer and
--- cfm
45.6 cfm 0.03 0.65
1 1-
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb Mar
HeatinJan Feb � Mar
Apr
Apr
Jul
May I I Jun Jul
Ma X Jun ri
Aug
Au
Se
Sep
[ ] Oct Nov
[ ] Oct Nov
Dec
Dec
Ventin Jan Feb X Mar
L
[
A r
[ Ma Jun Jul
L
[ Aug
l
Se
[X] Oct X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2
3 4 5 6
7
8
9 10 11
12
Cooling (WD) AM 78
78
78 78 78 78
78
78
80 80 80
80
PM 80
80
78 78 78 78
78
78
78 78 78
78
Cooling (WEH) AM 78
78
78 78 78 78
78
78
78 78 78
78
PM 78
78
78 78 -78 78
78
78
78 78 78
78
Heating (WD) AM 66
66
66 66 66 68
68
68
68 68 68
68
PM 68
68
68 68 68 68
68
68
68 68 66
66
Heating (WEH) AM 66
66
66 66 66 68
68
68
68 68 68
68
PM 68
68
68 68 68 68
68
68
68 68 66
66
MECHANICAL VENTILATION
Type Supply CFM
Exhaust CFM Fan Watts HRV Heating System
Run Time Cooling System
Runtime Vent 15
0 0 0 1 - Electric Strip Heat
% 1 - Central Unit
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Family Room
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Owner Suite
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Owner Suite Bath C
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Kitchen
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Bedroom 2
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Foyer and Hall
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Bedroom 3
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Laundry Room
Default(8 Ibs/s .ft.
0 ft2
O ft
0.3
Bathroom 2
5/20/2020 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
. 2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition ..
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R 4.2
2. Single-family or multiple -family
2. Single-family
b) Return ducts R 4.2
c) AHU location Foyer and Hall
3. No -of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity 34.0
a).Split system SEER 15.0
5. Is this a worst case? (yes/no)
5. Yes
b) Single package SEER
c) .Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1521
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 1.070
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.350
c) Area 7c. 198.1
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
10131.
10132. 11.0
11 a. 30.0
11 b.
1111c.
11d. No
14. Heating system: Capacity 32.8
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.95
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
b) Cross ventilation No
c) Whole house fan No
d) Multizone cooling credit
e)-Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
. Builder Signature:
Address of New Home: 5412 DELEON AVE City/FL Zip: FORT PIERCE, FL 34951
5/20/2020 9:41:15 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
• 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: SINGLE FAMILY HOME Builder Name:
Street: 5412 DELEON AVE Permit Office: FORT PIERCE CITY
City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: •
Y
U
Owner: 21ST STREET, LLC Jurisdiction: 661100
W
DesignLocation: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
WAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
5/20/2020 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Duct Leakage Test Report
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: 661100 I Permit #:
Builder: Community: Lot: NA
Address: 5412 DELEON AVE
City: FORT PIERCE State: FL Zip: 34951
System 1
cfm25
System 2
cfm25
System 3
cfm25
Sum of any
cfm25
Total of all
cfm25
1521 = Qn
Total of all
Total Conditioned
systems
Square Footage
PASS [:]FAIL
an the
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section
553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes.
Company Name: Phone:
I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the
selected compliance path as stated above, either the Prescriptive Method or Performance Method.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
5/20/2020 9:41:47 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Air System Sizing Summary for AHU & CU-1
Project Name: Single Family Home 05/20/2020
Prepared by: FES, Inc 09:02AM
Air System Information
Air System Name: ............................................... AHU & CU-1
Air System Type: ....................................... Single Zone CAV
Sizing Calculation Information
Calculation Months: ............................................... Jan to Dec
Central Cooling Coil Sizing Data
Total coil load:......-----:-------------------------------------------------------------2.8
Tons
Total coil load: ........................................................................
33.8
MBH
Sensible coil load: ................................................................30.9
MBH
Coil airflow:........................................... .................................
402
CFM
Sensible heat ratio: .......... ....................... .........................
0.914
Area per unit load: ------------------------- -------------------------------------
508.1
sgft/Ton
Load per unit area: ---------------------------------------------------------------
23.6
BTU/(hr-sgft)
Central Heating Coil Sizing Data
Maxcoil load: ..........................................................................
MBH
Coilairflow: ...................................... --------------------------------------1402
CFM
Load per unit area: ..................................................................
9.9
BTU/(hr-sgft)
Supply Fan Sizing Data
Actual max airflow: ....-_.------------------------------------------------------ 1402 CFM
Standard airflow: .................................................................. 1401 CFM
Actual max airflow per unit area: ..................................... 0.98 CFM/sqft
Outdoor Ventilation Air Data
Design airflow-------------------------------- ........................................ CFM
Airflow per unit floor area: ................... .............................. 0.00 CFM/sqft
Space Sizing Data
Number of zones: ...... ............. ......................-................. I
Floor Area-- ----- --- ------------------------- . -- .............-----------1432.3 sqft
Location: ------------ .. West Palm Beach, Florida
Calculation method: ........................... Radiant Time Series
Load occurs at:---.........................................................Jul 1500
CA DB / WB:................................................................ 92.0/79.0 F
Entering DB / WB:..........................
........--------------75.5/62.3 F
Leaving DB f WB: -----
. ...................-------......--.......55.0/53.8 F
CoilADP---------------------------------------------------- --- --- ---- ----- --------52.7 F
Bypass Factor: ...............................
------------------------------------ 0.100
ResultingRH----------------------------------------------
_............................ 48 %
Design supply temp-.............
-.............................................. 55.0 F
Load occurs at: .....................---- -- . ----------............. Des Htg
Ent DB / Lvg DB: -------- ................................................ 69.9179.2 F
Fan motor BHP: --------------------------------------------------------------------- 0.41 BHP
Fan motor kW----..................................................................... 0.30 kW
Fanstatic------------------------------------........... ..............----------1.00 in wg
Airflow per person:
Space Name .:. -
.,
Maximum
Cooling
Sensible
-:MBH
• .-Design
Airflow...,;"'
"•CFM'..
Time of Peak•
.." .Load
„
,
Maximum
,' Heating
Load:MBH
Space
Floor
Area
sqft
Space
'CFM/sgft
Bath 2
1.0
46
Jul 1600
0.7
52.0
0.88
Bedroom # 2
3.6
166
Jul 1700
1.9
119.3
1.39
Bedroom # 3
2.9
135
Oct 1400
1.5
123.0
1.10
Family Room / Kitchen
8.7
405
Jul 1500
5.5
569.0
0.71
Gallery
3.7
173
Jul 1600
1.3
220.0
0.79
Laundry
2.3
105
Jun 1600
0.6
38.0
2.77
Owner Bath
0:8
38
Jul 1600
0.6
46.0
0.83
Owner Suite
6.9
321
Jul 1500
2.7
194.0
1.66
Owner WIC
0.6
27
Jul 1600
0.31
46.01
0.58
WIC
0.11
61
Jul1600
0.11
25.0
0.26
Zone .- - ,. °.
30.3
., - 1402
'` Juf1500
, 15.3
:1432.3
• , 0.98
Note: Table contains data for all spaces controlled by a single thermostat:
Space sizing basis: .................. Peak space load
Zone sizing basis: ..................... .-Peak zone load
S.
Q':' ��GEIUSF •:��
* No. 43414
�= STATE OF
CFM/person
Block Load 4.16 Page 1 of 2