GENERAL NOTES:
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION
2. THE DESIGN & CONSTRUCTION OF THIS STRUCTURE MUST FULLY COMPLY WITH THE 2017 FLORIDA BUILDING CODE
(6TH EDITION), AC1318-05, NCMA, NATIONAL FOREST PRODUCT ASSOC., NOS, TPI-95, AND ANY OTHER NATIONALLY
RECOGNIZED ORGANIZATIONS THAT GOVERN THIS BODY OF WORK.
3. TRUSS MANUFACTURER SHALL SUBMIT SHOP DRAWINGS FOR BUILDERS APPROVAL. THESE DRAWINGS SHALL BE
SEALED BY A FLORIDA REGISTERED ENGINEER AND REVIEWED BY THE ENGINEER OF RECORD. THE ENGINEER OF
RECORD RESERVES THE RIGHT TO MAKE ANY NECESSARY CHANGES TO THE LAYOUT AND OR DESIGN OF SAID
DRAWINGS, AND SHALL NOTIFY THE TRUSS MANUFACTURER/TRUSS ENGINEER OF SAID CHANGES WITHIN 1 WEEK
OF RECEIVING THE SUBMITTED SHOP DRAWINGS.
4. ALL WORK SHALL COMPLY WITH ALL LOCAL AND REGIONAL ORDINANCES.
DESIGN PARAMETERS FOR WIND LOAD COMPLIANCE
1. RISK CATEGORY: 11
2. CODE REFERENCE: 2017 FLORIDA BUILDING CODE (6TH EDITION) & ASCE 7-10
3. BUILDING DESIGN: ENCLOSED
4. MEAN ROOF HEIGHT: <= 15.0'
5, ROOF PITCH: 3112 DEGREES
6. GCPIi: t 0.18
7. WIDTH OF END ZONE: A = 4.0'
8. WIND SPEED: 160 MPH (Vult) 3-SECOND GUST
124 MPH (Vasd) 3-SECOND GUST
9. WIND EXPOSURE: C
10. ADJUSTMENT FACTOR: 1.21
11. LOADS:
FLOORIDEAD 20 PSF
FLOOR/LIVE 40 PSF
ROOF/DEAD 17 PSF
ROORLIVE 20 PSF
WALL 18 PSF
12. SHEAR WALLS WERE CONSIDERED
13. A CONTINUOUS LOAD PATH WAS PROVIDED
14. COMPONENT & CLADDING DETAILED
15. MINIMUM SOIL BEARING PRESSURE IS 2,000 PSF PRESUMPTIVE
CONCRETE NOTES:
1. CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITIONS OF ACI 301 "SPECIFICATION FOR
STRUCTURAL CONCRETE FOR BUILDINGS" AND ACI 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL
CONCRETE.
2. STRUCTURAL CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ACI 301 AND SHALL ATTAIN A MINIMUM
COMPRESSIVE STRENGTH IN 28 DAYS OF 3,000 PSI. UNLESS NOTED OTHERWISE.
3. CONCRETE, WHEN PLACED, SHALL HAVE A SLUMP OF 4 INCHES PLUS OR MINUS ONE INCH.
4, PROVIDE A MINIMUM OF 6 MIL VAPOR BARRIER AT ALL AIR CONDITIONED SPACES & GARAGES. HOLES IN VAPOR
BARRIER ARE NOT PERMITTED. TAPE AROUND ALL SEAMS AND CUT-OUTS.
5. ALL REINFORCING SHALL CONFORM TO ASTM A615 FOR GRADE 60 STEELIWELDED WIRE MESH TO CONFORM TO
ASTM A-185
5.1. PROVIDE CHAIRS AND BOLSTERS
5.1.1. BOLSTERS TO HAVE PLASTIC COATED LEGS AND FEET (IF EXPOSED TO EXTERIOR ELEMENTS)
5.2. ENSURE MESH IS EMBEDDED 1" FROM THE TOP OF THE SLAB. LAP JOINTS AT 8" & TIE.
6. WELDED WIRE FABRIC SHALL BE IN ACCORDANCE WITH ASTM A-185 AND SHALL BE ADEQUATELY SUPPORTED @
T-0" O.C. EACH WAY
7. THE MINIMUM CONCRETE COVERAGE SHALL BE AS FOLLOWS:
7.1. CAST AGAINST EARTH: 3"
7.2. EXPOSED TO EXTERIOR ELEMENTS: V
7.3. FORMED SURFACES: 1"
8. CONSTRUCTION JOINTS DESIGN AND LOCATION SHALL CONFORM STRICTLY TO THE REQUIREMENTS OF THE PLANS
AND SPECIFICATIONS. ANY CONSTRUCTION OR CONTROL DESIRED OR PREFERRED BY THE CONTRACTOR SHALL
BE APPROVED BY THE ENGINEER PRIOR TO CONSTRUCTION OF THOSE AREAS INVOLVED.
9. CHECK ALL DRAWINGS AND APPLICABLE MANUFACTURER'S SHOP DRAWINGS FOR LOCATION OF ALL EMBEDDED
ITEMS, SUCH AS PIPE SLEEVES, ANCHOR BOLTS, ETC PRIOR TO PLACING CONCRETE.
10. REINFORCEMENT FOR CONTINUOUS FOOTINGS SHALL BE CONTINUOUS AND SPLICED WITH A FULL 0 INCH LAP.
PROVIDE CORNER BARS.
11. CONTRACTOR SHALL PROVIDE SAWCUTS IN SLAB @ A MAX. SPACING OF 20 FEET ON CENTER EACH WAY OR 400 S.F.
AND AT ALL RE-ENTRANT CORNERS. SAW CUT SHALL BE 1/4 OF THE SLAB DEPTH AND SHALL BE PERFORMED AS
SOON AS THE CONCRETE HAS HARDENED SUFFICIENTLY ENOUGH TO CONTROL THE STRESSES, AN INHERENT
PROPERTY OF CONCRETE WHICH SOMETIMES RESULTS IN CRACKS (WHICH IS NOT UNCOMMON)
12, CONCRETE FOR SLABS ON GRADE AND ELEVATED SLABS SHALL HAVE 3/4" LARGE AGGREGATE. "PEAROCK" IS NOT
PERMITTED FOR SLABS.
13. CONCRETE PORCH OUTRIGGERS, EXTERIOR FORMED AND POURED COLUMNS, AND REINFORCED EXTERIOR SLABS
SHALL CONTAIN W.R.GRACE DCI-S CORROSION INHIBITOR AT THE RATE OF 2-1/2 GALLONS PER YARD. CONCRETE
SHALL HAVE A MAX. W/C RATIO OF 0.04 AND A MIN. DESIGN STRENGTH OF 5000 PSI @ 28 DAYS.
13.1. ELEVATED SLABS SHALL BE TEMPORARILY SHORED UNTIL FULLY CURED.
14. ALL CONCRETE THAT IS ALTERED (WATER, ADDITIVES, ETC) SHALL BE TESTED TO ENSURE STRENGTH
REQUIREMENTS ARE MET.
15. TERMINATE ALL VERTICAL REINFORCING AT THE TOP AND BOTTOM WITH 10" ACI HOOKS.
16. SOILS SHALL BE TREATED.
FOUNDATION NOTES:
1. SOIL TO BE COMPACTED TO AT LEAST 95% OF MAX. DRY DENSITY AS DETERMINED BY ASTM-1557 (MODIFIED
PROCTOR).
2. FOUNDATIONS ARE DESIGNED BASED ON PRESUMPTIVE SAFE MINIMUM SOIL BEARING PRESSURE OF 2000 PSF.
3. FOOTINGS SHALL BE PLACED ON COMPACTED SOIL FREE OF ORGANIC DEBRIS.
WINDOW AND DOOR NOTES:
1. WINDOWS, DOORS, SHUTTERS, AND ALL COMPONENTS SHALL BE DESIGNED AND INSTALLED PER THE MINIMUM
DESIGN PRESSURES AS PRESCRIBED IN THESE PLANS.
2. ALL EXTERIOR GLAZING SHALL BE IMPACT RESISTANT OR HAVE PROTECTION PER SECTION R301.2.1.1 OF THE 2017
FBC RESIDENTIAL CODE, PROTECTION SHALL BE DESIGNED FOR THE SAME WIND DESIGN PRESSURES AS THE
WINDOWS OR DOORS THEY ARE COVERING.
3. ALL WINDOWS AND DOORS ARE TO BE INSTALLED ON 2X PRESSURE TREATED BUCKS, AND AS PER
MANUFACTURERS SPECIFICATIONS UNLESS OTHERWISE NOTED.
TIMBER NOTES:
1. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY A FLORIDA REGISTERED ENGINEER FOR ALL LOADS
PRESCRIBED. ROOF TRUSS ENGINEERING SHOP DRAWINGS SHALL INCLUDE TRUSS LAYOUT, DESIGN LOADS, TRUSS
REACTION, (DEAD LOAD & LIVE LOAD AND DEAD LOAD & WIND LOAD), AND ALL OTHER INFORMATION REQUIRED FOR
PROPER TRUSS INSTALLATION, ERECTION AND BRACING CRITERIA. DESIGN OF ROOF TRUSSES SHALL IN0.UDE THE
UPLIFT EFFECTS OF 160 MPH DESIGN WIND LOAD BASED ON THE 2017 FLORIDA BUILDING CODE, 6TH EDITION.
1.1. ROOF TRUSSES SHALL NOT BE DELIVERED TO THE CONSTRUCTION SITE MORE THAN 3 DAYS PRIOR TO
INSTALLATION, AND SHALL BE STORED IN ACCORDANCE WITH TPI-95.
1.2. TRUSS ENGINEER SHALL PROVIDE A WEB MEMBER AT ANY AND ALL PITCH CHANGES OF THE TOP AND BOTTOM
CHORD, EXTENDING TO PANEL POINT ON OPPOSITE CHORD. MAX. LENGTH OF BOTTOM PANEL SHALL NOT
EXCEED 9 FT. EXCEPT @ SHORT TRUSS HEELS WHERE REQUIRED HURRICANE STRAP WILL BEND OVERTOP
CHORD. PROVIDE VERTICAL WEB OVER ALL TRUSS BEARING LOCATIONS.
1.3. ALL MEMBERS SHALL BE A MINIMUM OF 2 X 4 #2 SYP.
1.4. ALL VALLEY SETS SHALL BE FRAMED WITH VALLEY SET TRUSSES AND ATTACHED TO TRUSSES BELOW PER
SPECIFIED STRAPPING @ 6' O.C. MAX. ROOF PLYWOOD SHALL EXTEND ON TRUSSES BENEATH ALL OVER
FRAMING. OMIT PLYWOOD AND VALLEY SET BOTTOM CHORD BETWEEN TWO TRUSSES FOR ACCESS.
1.5. IN ADDITION TO THE DESIGN LOADS LISTED, THE TRUSSES SHALL BE DESIGNED FOR ADDITIONAL LOADS
WHERE APPLICABLE (I.E. A/C EQUIPMENT, ETC.)
1.6. DESIGN BOTTOM CHORDS FOR ATTIC TRUSSES FOR LIVE LOAD PER 2017 FBC R301.5. TRUSSES SUPPORTING
MECHANICAL EQUIP. SHALL BE DESIGNED FOR (2)100 LB POINT LOADS T APART LOCATED ANYWHERE ON THE
TOP CHORD.
1.7. TRUSSES MUST BE CONFIGURED TO PROPERLY ATTACH ALL HANGERS SHOWN ON PLANS OR IN SHOP
DRAWINGS. TRUSS ENGINEER MUST SPECIFY ALL TRUSS TO TRUSS CONNECTIONS.
1.8, ALL ROOF TRUSSES AND RAFTERS SHALL BE ANCHORED WITH A TRUSS CONNECTOR STRAP AS PER PLAN OR
SCHEDULE & A VAPOR BARRIER MUST BE PROVIDED BETWEEN TRUSSES AND CONCRETE.
2. ROOF SHEATHING SHALL BE A MIN. OF 5/8" CDX SPAN RATED STRUCTURAL PLYWOOD, INSTALLED WITH FACE GRAIN
PERPENDICULAR TO ROOF FRAMING WITH 10d RING SHANK NAILS 6" O.C. AT PANEL EDGES AND 6" O.C. IN THE FIELD.
PROVIDE 2" X 4" BLOCKING AT HIPS AND VALLEYS. SPACE NAILS AT 4" O.C. AT BLOCKING.
3. EXTERIOR FRAME WALLS SHEATHING TO BE SHEATHED WITH 5/8" APA SHEATHING, SPECIES GROUP 1, SPAN RATING
OF 24/0 OR BETTER. UNLESS OTHERWISE NOTED, INSTALL WITH FACE GRAIN HORIZONTAL. PLYWOOD SHALL BE 4
PLY MINIMUM. NAIL TO STUDS USING 10d NAILS @ 4" O.C. AT PANEL EDGES AND 10- O.C. IN THE FIELD. DECREASE
SPACING PER PLAN. AT SHEAR WALLS, NAIL TO EACH STUD AT THE END OF THE WALLS FOLLOWING THE EDGE
SPACING. BACK OUT AND REMOVE ALL NAILS THAT DO NOT FULLY PENETRATE/MISS FRAMING MEMBERS..
4. FLOOR SHEATHING TO BE 3/4" T & G COX SPAN RATED STRUCTURAL PLYWOOD, INSTALLED WITH FACE GRAIN
PERPENDICULAR TO FLOOR FRAMING GLUED & NAILED WITH 1Od NAILS 6" O.C. AT PANEL EDGES AND 12" O.C. IN THE
FIELD.
5. THE MINIMUM LUMBER GRADES SHALL BE AS SUCH: INT. & EXT. BEARING WALLS, TOP PLATES, WINDOW BUCKS, &
HEADERS: SOUTHERN YELLOW PINE #2 OR BETTER
BOTTOM PLATES AGAINST CONCRETE: PRESSURE TREATED SOUTHERN YELLOW PINE #2 OR BETTER
6. ALL TIMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED OR HAVE AN APPROVED
SEPARATING MATERIAL.
7. ALL NAILS AND METAL HARDWARE EXPOSED TO THE ELEMENTS SHALL BE GALVANIZED. ALL NAILS SHALL BE
COMMON WIRE NAILS. SPACE NAILS AT STRAPS AS TO NOT SPLIT THE WOOD.
1►J/1�1�7�i7�\�7�7�9[e3�[�77i1r
1. DESIGN WIND LOAD ON INDIVIDUAL ROOF TRUSSES BASE UPON TRIBUTARY AREA SHALL BE AS
FOLLOWS.
2. SEE ROOF PLAN FOR ZONE LOCATIONS.
3. OVERHANGS SHALL INCLUDE PORCHES, BALCONY ROOFS, ETC.
4. MAXIMUM DEADLOAD RESISTING UPLIFT SHOWN BELOW SHALL BE 8 PSF.
FOR 3:12 ROOF PITCH
ZONE
AREA
PRESSURE
PRESSURE
OVERHANG
2
10
53
19
62
2
20
49
18
62
2
50
43
15
62
2
100
39
14
62
3
10
79
19
105
3
20
74
18
95
3
50
67
15
81
3
100
62
14
76
EXTERIOR COMPONENTS ATTACHED TO THE WALL (SIDING, ETC):
1. EXTERIOR WALL COMPONENTS SHALL BE ATTACHED PER MANUFACTURERS REQUIREMENTS TO
MEET THE WIND PRESSURES SHOWN,
2. END ZONE IS AT EXTERIOR CORNER, UNDER ROOF ZONE 3. INTERIOR ZONE IS REMAINDER.
WALL ZONE
NEGATIVE
END
36 PSF
29 PSF
INTERIOR
29 PSF
26 PSF
QnCCITQ.
ZONE
DESIGN PRESSURE
2
+32 / -35 PSF
3
+32 / -42 PSF
ELECTRICAL LEGEND
TYPE
DESCRIPTION
(D-
_
DUPLEX RECEPTACLE
opFi
GROUND FAULT CIRCUIT DUPLEX RECEPTACLE
-¢-
SURFACE MOUNTED CEILING LIGHT
�-¢-
WALL MOUNTED LIGHT
O
RECESSED CEILING LIGHT
OSD/ D
SMOKE DETECTOR (110 V)
19
EXHAUSTFAN
$
SWITCH
CEILING FAN
EXISTING RESIDENCE
b , ' BATHROOM
GFI
NOTE:
ELECTRICAL LAYOUT ARE SUGGESTIONS ONLY.
ALL ELECTRICAL TO BE PER 2014 FBC & 2011 NEC &
PERFORMED BY A STATE REGISTERED ELECTRICAL
CONTRACTOR.
ELECTRICAL SERVICE TO BE UNDERGROUND SUPPLY.
1
ELECTRICAL PLAN
SCALE: 1/4" = 1'-O"
TRUSS CONNECTION SCHEDULE
UPLIFT
Mom'
HARDWARE
CONNECTION NOTES
FASTENER
UPLIFT
SPECIFICATION
379
600
H2.5A
COMMON TRUSS TO WOOD
(10) 8d NAILS
BEAM
NOTE:
ALL TRUSS CONNECTORS ARE SIMPSON STRONG -TIE Z-MAX. (WHERE AVAILABLE) (TYP.)
INSTALLED WITH MAXIMUM NAILS, SCREWS, BOLTS AS PER MANUFACTURERS SPECIFICATIONS
H2.5A )
ROOF FRAMING PLAN
SCALE: 1/4" = V-0"
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
(2) 2" X 8" RIDGE BEAM W/
SIMPSON A35Z
CONNECTION TO 2" X 6"
RAFTERS EA. SIDE EXISTING RESIDENCE
SIMPSON H2.5A J
TO BEAM &RAFTER W/ (8)
10d X 1 1/2" NAILS 3 1�. - '
4
ALUM. DRIP EDGE OVER 1" X 8"
CEDAR FASCIA OVER 2" X 6" SUB 1'-0" E2468
FASCIA ATTACHED TO TRUSSES O.H.
W/(3) 16d NAILS EA. TRUSS TYP. 2" X 4" STUD WALL ATTACHED
TO EXIST. WALL W/ 3/8" X 4" S.S. 2" X 4" STUD WALL ATTACHED
2" X 4" TOP PLATE W/ OR GALV. LAG SCREWS @ 4" TO EXIST. WALL W/3/8" X 4" S.S.
SIMPSON SP4 @ 32" O.C. O.C. FROM EA. COLUMN & 16"
STAGGERED CENTERS THRU '4 BATHROOM OR GALV. LAG SCREWS @ 4"
in O.C. FROM EA. COLUMN & 16"
(2) 2" X 8" W/ 1/2" COX STAGGERED CENTERS THRU
FLITCH PLATE HEADER SHOWER SIN K
STRAPPED TO THE JACK o 0 0
STUDS W/ SIMPSON rj
LSTA18 STRAPS W/ (14) 10d
NAILS (7 EA. SIDE) m
0
+32/42 PSF m
R-13 INSULATION 15'-4" 2'-3"
2" X 4" WOOD STUD WALL 16" O.C. W/
HARDI-PANEL SIDING OVER 1/2" COX 1/2" GYP. BD. DRYWALL NOTE: ALL DIMENSIONS
SHEATHING Wl8d NAILS @ 6" O.C. AT FLOOR FRAMING PLAN TO BE VERIFIED IN FIELD
THE EDGES & 10" O.C. IN THE FIELD
y/ SCALE: 1/4" = 1'-0"
HARDI-PANEL SIDING, SEE FLORIDA 2" X 4" PT #2 SYP BOTTOM PLATE C _ TY Bl
PRODUCT APPROVAL INSTALLATION ATTACHED W/ 1/2" WEDGE ST. LL' I C LTA" BIZLDI`:G E,T"�^EON
INSTRUCTIONS (FL 13192.2) ANCHOR gEVIE I FO hC
iZEVIENE B � '
NEW 4" THICK CONCRETE FLOOR SLAB, 3,000 'DATE
SIMPSON SP4 @ 32" O.C. @ BOTTOM P.S.I. MIN. WITH TROWEL SMOOTH FINISH %I,puTS 'VD %ERIIIT MUST BE KEPT ON JOB #4 X 1IN BAR DOWEL &EPDXY 4 INTO
REINFORCED WITH 6" X 6" - W1.4AN1.4 W.W. MESH Q is�J ;a;SPECTION WILL BE HiADB" EXISTING FOOTING/SLAB & @ 24" O.C.
OR FIBER MESH W/ 6 MIL VAPOR BARRIER ON
--f COMPACTED TREATED SOIL -BROOM FINISH
EXISTING FOUNDATION
L AND SLAB TO REMAIN
9
0
16" X 12" CONC. FOOTING W/ (2) #5 V-4" I DOWEL & EPDXY (2) #5 X 36" BARS 6"
BARS CONT. INTO EXISTING FOUNDATION (30" LAP
SPLICE)(EA. SIDE WHERE NEW
FOUNDATION MEETS OLD)
WALL SECTION
SCALE: 3/4" = V-0"
NEW BATHROOM ADDITI
FOUNDATION PLAN
SCALE.: 1/4" = 1'-0"
Ln
E
iu m
U
pM 0
f0
U
)
N
O
mmN
P E
d m�
V)
rn
04
tiMLLIM
W N�1-ik
Z N f p m
1
CL��wa
(�
ar-u)�U
4-1
0
a co
N M
N M LL
V /
M
-oo (p N
v
LL > C7
ul m
®
L U Q U
2 am
iu
a O E
OD > v IL
SEAT 0` •
.10°.
�Iy
i
LL
00
3 u
W -w 6
z
C
i'
E E'ga
"2Br
® ai
co
W
N
O
N
0
W
F
5
1n
U)
a
W
tY
I-
W
W
(� I
W
co
On
J
Ln
Rt
VO1
LU
00
M
❑
z
a
p
iLL
g
a
W
W_
0_
H
W
m
O
0
In
ua¢
0
c:
Q
�y
J
W
❑
Z
❑
W
v
O
I✓
=
z
O
J
cn
O
w
r
.Gz
NWi
WN
4�(5
�z
PROJ. NO. 17-4840
DATE 03/07/2018
SHEET NO.
SHEET 1 OF 2