HomeMy WebLinkAboutBuilding Plansa rn N N Lo ai W 2 O N rn N M LU Q ❑ C N �C W 00 lqT O Y W O 00 r` ❑ Q U_ W J n GENERAL NOTES: 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION 2. THE DESIGN & CONSTRUCTION OF THIS STRUCTURE MUST FULLY COMPLY WITH THE 2017 FLORIDA BUILDING CODE (6TH EDITION), AC1318-05, NCMA, NATIONAL FOREST PRODUCT ASSOC., NOS, TPI-95, AND ANY OTHER NATIONALLY RECOGNIZED ORGANIZATIONS THAT GOVERN THIS BODY OF WORK. 3. TRUSS MANUFACTURER SHALL SUBMIT SHOP DRAWINGS FOR BUILDERS APPROVAL. THESE DRAWINGS SHALL BE SEALED BY A FLORIDA REGISTERED ENGINEER AND REVIEWED BY THE ENGINEER OF RECORD. THE ENGINEER OF RECORD RESERVES THE RIGHT TO MAKE ANY NECESSARY CHANGES TO THE LAYOUT AND OR DESIGN OF SAID DRAWINGS, AND SHALL NOTIFY THE TRUSS MANUFACTURER/TRUSS ENGINEER OF SAID CHANGES WITHIN 1 WEEK OF RECEIVING THE SUBMITTED SHOP DRAWINGS. 4. ALL WORK SHALL COMPLY WITH ALL LOCAL AND REGIONAL ORDINANCES. DESIGN PARAMETERS FOR WIND LOAD COMPLIANCE 1. RISK CATEGORY: 11 2. CODE REFERENCE: 2017 FLORIDA BUILDING CODE (6TH EDITION) & ASCE 7-10 3. BUILDING DESIGN: ENCLOSED 4. MEAN ROOF HEIGHT: <= 15.0' 5, ROOF PITCH: 3112 DEGREES 6. GCPIi: t 0.18 7. WIDTH OF END ZONE: A = 4.0' 8. WIND SPEED: 160 MPH (Vult) 3-SECOND GUST 124 MPH (Vasd) 3-SECOND GUST 9. WIND EXPOSURE: C 10. ADJUSTMENT FACTOR: 1.21 11. LOADS: FLOORIDEAD 20 PSF FLOOR/LIVE 40 PSF ROOF/DEAD 17 PSF ROORLIVE 20 PSF WALL 18 PSF 12. SHEAR WALLS WERE CONSIDERED 13. A CONTINUOUS LOAD PATH WAS PROVIDED 14. COMPONENT & CLADDING DETAILED 15. MINIMUM SOIL BEARING PRESSURE IS 2,000 PSF PRESUMPTIVE CONCRETE NOTES: 1. CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITIONS OF ACI 301 "SPECIFICATION FOR STRUCTURAL CONCRETE FOR BUILDINGS" AND ACI 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. 2. STRUCTURAL CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ACI 301 AND SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH IN 28 DAYS OF 3,000 PSI. UNLESS NOTED OTHERWISE. 3. CONCRETE, WHEN PLACED, SHALL HAVE A SLUMP OF 4 INCHES PLUS OR MINUS ONE INCH. 4, PROVIDE A MINIMUM OF 6 MIL VAPOR BARRIER AT ALL AIR CONDITIONED SPACES & GARAGES. HOLES IN VAPOR BARRIER ARE NOT PERMITTED. TAPE AROUND ALL SEAMS AND CUT-OUTS. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615 FOR GRADE 60 STEELIWELDED WIRE MESH TO CONFORM TO ASTM A-185 5.1. PROVIDE CHAIRS AND BOLSTERS 5.1.1. BOLSTERS TO HAVE PLASTIC COATED LEGS AND FEET (IF EXPOSED TO EXTERIOR ELEMENTS) 5.2. ENSURE MESH IS EMBEDDED 1" FROM THE TOP OF THE SLAB. LAP JOINTS AT 8" & TIE. 6. WELDED WIRE FABRIC SHALL BE IN ACCORDANCE WITH ASTM A-185 AND SHALL BE ADEQUATELY SUPPORTED @ T-0" O.C. EACH WAY 7. THE MINIMUM CONCRETE COVERAGE SHALL BE AS FOLLOWS: 7.1. CAST AGAINST EARTH: 3" 7.2. EXPOSED TO EXTERIOR ELEMENTS: V 7.3. FORMED SURFACES: 1" 8. CONSTRUCTION JOINTS DESIGN AND LOCATION SHALL CONFORM STRICTLY TO THE REQUIREMENTS OF THE PLANS AND SPECIFICATIONS. ANY CONSTRUCTION OR CONTROL DESIRED OR PREFERRED BY THE CONTRACTOR SHALL BE APPROVED BY THE ENGINEER PRIOR TO CONSTRUCTION OF THOSE AREAS INVOLVED. 9. CHECK ALL DRAWINGS AND APPLICABLE MANUFACTURER'S SHOP DRAWINGS FOR LOCATION OF ALL EMBEDDED ITEMS, SUCH AS PIPE SLEEVES, ANCHOR BOLTS, ETC PRIOR TO PLACING CONCRETE. 10. REINFORCEMENT FOR CONTINUOUS FOOTINGS SHALL BE CONTINUOUS AND SPLICED WITH A FULL 0 INCH LAP. PROVIDE CORNER BARS. 11. CONTRACTOR SHALL PROVIDE SAWCUTS IN SLAB @ A MAX. SPACING OF 20 FEET ON CENTER EACH WAY OR 400 S.F. AND AT ALL RE-ENTRANT CORNERS. SAW CUT SHALL BE 1/4 OF THE SLAB DEPTH AND SHALL BE PERFORMED AS SOON AS THE CONCRETE HAS HARDENED SUFFICIENTLY ENOUGH TO CONTROL THE STRESSES, AN INHERENT PROPERTY OF CONCRETE WHICH SOMETIMES RESULTS IN CRACKS (WHICH IS NOT UNCOMMON) 12, CONCRETE FOR SLABS ON GRADE AND ELEVATED SLABS SHALL HAVE 3/4" LARGE AGGREGATE. "PEAROCK" IS NOT PERMITTED FOR SLABS. 13. CONCRETE PORCH OUTRIGGERS, EXTERIOR FORMED AND POURED COLUMNS, AND REINFORCED EXTERIOR SLABS SHALL CONTAIN W.R.GRACE DCI-S CORROSION INHIBITOR AT THE RATE OF 2-1/2 GALLONS PER YARD. CONCRETE SHALL HAVE A MAX. W/C RATIO OF 0.04 AND A MIN. DESIGN STRENGTH OF 5000 PSI @ 28 DAYS. 13.1. ELEVATED SLABS SHALL BE TEMPORARILY SHORED UNTIL FULLY CURED. 14. ALL CONCRETE THAT IS ALTERED (WATER, ADDITIVES, ETC) SHALL BE TESTED TO ENSURE STRENGTH REQUIREMENTS ARE MET. 15. TERMINATE ALL VERTICAL REINFORCING AT THE TOP AND BOTTOM WITH 10" ACI HOOKS. 16. SOILS SHALL BE TREATED. FOUNDATION NOTES: 1. SOIL TO BE COMPACTED TO AT LEAST 95% OF MAX. DRY DENSITY AS DETERMINED BY ASTM-1557 (MODIFIED PROCTOR). 2. FOUNDATIONS ARE DESIGNED BASED ON PRESUMPTIVE SAFE MINIMUM SOIL BEARING PRESSURE OF 2000 PSF. 3. FOOTINGS SHALL BE PLACED ON COMPACTED SOIL FREE OF ORGANIC DEBRIS. WINDOW AND DOOR NOTES: 1. WINDOWS, DOORS, SHUTTERS, AND ALL COMPONENTS SHALL BE DESIGNED AND INSTALLED PER THE MINIMUM DESIGN PRESSURES AS PRESCRIBED IN THESE PLANS. 2. ALL EXTERIOR GLAZING SHALL BE IMPACT RESISTANT OR HAVE PROTECTION PER SECTION R301.2.1.1 OF THE 2017 FBC RESIDENTIAL CODE, PROTECTION SHALL BE DESIGNED FOR THE SAME WIND DESIGN PRESSURES AS THE WINDOWS OR DOORS THEY ARE COVERING. 3. ALL WINDOWS AND DOORS ARE TO BE INSTALLED ON 2X PRESSURE TREATED BUCKS, AND AS PER MANUFACTURERS SPECIFICATIONS UNLESS OTHERWISE NOTED. TIMBER NOTES: 1. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY A FLORIDA REGISTERED ENGINEER FOR ALL LOADS PRESCRIBED. ROOF TRUSS ENGINEERING SHOP DRAWINGS SHALL INCLUDE TRUSS LAYOUT, DESIGN LOADS, TRUSS REACTION, (DEAD LOAD & LIVE LOAD AND DEAD LOAD & WIND LOAD), AND ALL OTHER INFORMATION REQUIRED FOR PROPER TRUSS INSTALLATION, ERECTION AND BRACING CRITERIA. DESIGN OF ROOF TRUSSES SHALL IN0.UDE THE UPLIFT EFFECTS OF 160 MPH DESIGN WIND LOAD BASED ON THE 2017 FLORIDA BUILDING CODE, 6TH EDITION. 1.1. ROOF TRUSSES SHALL NOT BE DELIVERED TO THE CONSTRUCTION SITE MORE THAN 3 DAYS PRIOR TO INSTALLATION, AND SHALL BE STORED IN ACCORDANCE WITH TPI-95. 1.2. TRUSS ENGINEER SHALL PROVIDE A WEB MEMBER AT ANY AND ALL PITCH CHANGES OF THE TOP AND BOTTOM CHORD, EXTENDING TO PANEL POINT ON OPPOSITE CHORD. MAX. LENGTH OF BOTTOM PANEL SHALL NOT EXCEED 9 FT. EXCEPT @ SHORT TRUSS HEELS WHERE REQUIRED HURRICANE STRAP WILL BEND OVERTOP CHORD. PROVIDE VERTICAL WEB OVER ALL TRUSS BEARING LOCATIONS. 1.3. ALL MEMBERS SHALL BE A MINIMUM OF 2 X 4 #2 SYP. 1.4. ALL VALLEY SETS SHALL BE FRAMED WITH VALLEY SET TRUSSES AND ATTACHED TO TRUSSES BELOW PER SPECIFIED STRAPPING @ 6' O.C. MAX. ROOF PLYWOOD SHALL EXTEND ON TRUSSES BENEATH ALL OVER FRAMING. OMIT PLYWOOD AND VALLEY SET BOTTOM CHORD BETWEEN TWO TRUSSES FOR ACCESS. 1.5. IN ADDITION TO THE DESIGN LOADS LISTED, THE TRUSSES SHALL BE DESIGNED FOR ADDITIONAL LOADS WHERE APPLICABLE (I.E. A/C EQUIPMENT, ETC.) 1.6. DESIGN BOTTOM CHORDS FOR ATTIC TRUSSES FOR LIVE LOAD PER 2017 FBC R301.5. TRUSSES SUPPORTING MECHANICAL EQUIP. SHALL BE DESIGNED FOR (2)100 LB POINT LOADS T APART LOCATED ANYWHERE ON THE TOP CHORD. 1.7. TRUSSES MUST BE CONFIGURED TO PROPERLY ATTACH ALL HANGERS SHOWN ON PLANS OR IN SHOP DRAWINGS. TRUSS ENGINEER MUST SPECIFY ALL TRUSS TO TRUSS CONNECTIONS. 1.8, ALL ROOF TRUSSES AND RAFTERS SHALL BE ANCHORED WITH A TRUSS CONNECTOR STRAP AS PER PLAN OR SCHEDULE & A VAPOR BARRIER MUST BE PROVIDED BETWEEN TRUSSES AND CONCRETE. 2. ROOF SHEATHING SHALL BE A MIN. OF 5/8" CDX SPAN RATED STRUCTURAL PLYWOOD, INSTALLED WITH FACE GRAIN PERPENDICULAR TO ROOF FRAMING WITH 10d RING SHANK NAILS 6" O.C. AT PANEL EDGES AND 6" O.C. IN THE FIELD. PROVIDE 2" X 4" BLOCKING AT HIPS AND VALLEYS. SPACE NAILS AT 4" O.C. AT BLOCKING. 3. EXTERIOR FRAME WALLS SHEATHING TO BE SHEATHED WITH 5/8" APA SHEATHING, SPECIES GROUP 1, SPAN RATING OF 24/0 OR BETTER. UNLESS OTHERWISE NOTED, INSTALL WITH FACE GRAIN HORIZONTAL. PLYWOOD SHALL BE 4 PLY MINIMUM. NAIL TO STUDS USING 10d NAILS @ 4" O.C. AT PANEL EDGES AND 10- O.C. IN THE FIELD. DECREASE SPACING PER PLAN. AT SHEAR WALLS, NAIL TO EACH STUD AT THE END OF THE WALLS FOLLOWING THE EDGE SPACING. BACK OUT AND REMOVE ALL NAILS THAT DO NOT FULLY PENETRATE/MISS FRAMING MEMBERS.. 4. FLOOR SHEATHING TO BE 3/4" T & G COX SPAN RATED STRUCTURAL PLYWOOD, INSTALLED WITH FACE GRAIN PERPENDICULAR TO FLOOR FRAMING GLUED & NAILED WITH 1Od NAILS 6" O.C. AT PANEL EDGES AND 12" O.C. IN THE FIELD. 5. THE MINIMUM LUMBER GRADES SHALL BE AS SUCH: INT. & EXT. BEARING WALLS, TOP PLATES, WINDOW BUCKS, & HEADERS: SOUTHERN YELLOW PINE #2 OR BETTER BOTTOM PLATES AGAINST CONCRETE: PRESSURE TREATED SOUTHERN YELLOW PINE #2 OR BETTER 6. ALL TIMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED OR HAVE AN APPROVED SEPARATING MATERIAL. 7. ALL NAILS AND METAL HARDWARE EXPOSED TO THE ELEMENTS SHALL BE GALVANIZED. ALL NAILS SHALL BE COMMON WIRE NAILS. SPACE NAILS AT STRAPS AS TO NOT SPLIT THE WOOD. 1►J/1�1�7�i7�\�7�7�9[e3�[�77i1r 1. DESIGN WIND LOAD ON INDIVIDUAL ROOF TRUSSES BASE UPON TRIBUTARY AREA SHALL BE AS FOLLOWS. 2. SEE ROOF PLAN FOR ZONE LOCATIONS. 3. OVERHANGS SHALL INCLUDE PORCHES, BALCONY ROOFS, ETC. 4. MAXIMUM DEADLOAD RESISTING UPLIFT SHOWN BELOW SHALL BE 8 PSF. FOR 3:12 ROOF PITCH ZONE AREA PRESSURE PRESSURE OVERHANG 2 10 53 19 62 2 20 49 18 62 2 50 43 15 62 2 100 39 14 62 3 10 79 19 105 3 20 74 18 95 3 50 67 15 81 3 100 62 14 76 EXTERIOR COMPONENTS ATTACHED TO THE WALL (SIDING, ETC): 1. EXTERIOR WALL COMPONENTS SHALL BE ATTACHED PER MANUFACTURERS REQUIREMENTS TO MEET THE WIND PRESSURES SHOWN, 2. END ZONE IS AT EXTERIOR CORNER, UNDER ROOF ZONE 3. INTERIOR ZONE IS REMAINDER. WALL ZONE NEGATIVE END 36 PSF 29 PSF INTERIOR 29 PSF 26 PSF QnCCITQ. ZONE DESIGN PRESSURE 2 +32 / -35 PSF 3 +32 / -42 PSF ELECTRICAL LEGEND TYPE DESCRIPTION (D- _ DUPLEX RECEPTACLE opFi GROUND FAULT CIRCUIT DUPLEX RECEPTACLE -¢- SURFACE MOUNTED CEILING LIGHT �-¢- WALL MOUNTED LIGHT O RECESSED CEILING LIGHT OSD/ D SMOKE DETECTOR (110 V) 19 EXHAUSTFAN $ SWITCH CEILING FAN EXISTING RESIDENCE b , ' BATHROOM GFI NOTE: ELECTRICAL LAYOUT ARE SUGGESTIONS ONLY. ALL ELECTRICAL TO BE PER 2014 FBC & 2011 NEC & PERFORMED BY A STATE REGISTERED ELECTRICAL CONTRACTOR. ELECTRICAL SERVICE TO BE UNDERGROUND SUPPLY. 1 ELECTRICAL PLAN SCALE: 1/4" = 1'-O" TRUSS CONNECTION SCHEDULE UPLIFT Mom' HARDWARE CONNECTION NOTES FASTENER UPLIFT SPECIFICATION 379 600 H2.5A COMMON TRUSS TO WOOD (10) 8d NAILS BEAM NOTE: ALL TRUSS CONNECTORS ARE SIMPSON STRONG -TIE Z-MAX. (WHERE AVAILABLE) (TYP.) INSTALLED WITH MAXIMUM NAILS, SCREWS, BOLTS AS PER MANUFACTURERS SPECIFICATIONS H2.5A ) ROOF FRAMING PLAN SCALE: 1/4" = V-0" REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC (2) 2" X 8" RIDGE BEAM W/ SIMPSON A35Z CONNECTION TO 2" X 6" RAFTERS EA. SIDE EXISTING RESIDENCE SIMPSON H2.5A J TO BEAM &RAFTER W/ (8) 10d X 1 1/2" NAILS 3 1�. - ' 4 ALUM. DRIP EDGE OVER 1" X 8" CEDAR FASCIA OVER 2" X 6" SUB 1'-0" E2468 FASCIA ATTACHED TO TRUSSES O.H. W/(3) 16d NAILS EA. TRUSS TYP. 2" X 4" STUD WALL ATTACHED TO EXIST. WALL W/ 3/8" X 4" S.S. 2" X 4" STUD WALL ATTACHED 2" X 4" TOP PLATE W/ OR GALV. LAG SCREWS @ 4" TO EXIST. WALL W/3/8" X 4" S.S. SIMPSON SP4 @ 32" O.C. O.C. FROM EA. COLUMN & 16" STAGGERED CENTERS THRU '4 BATHROOM OR GALV. LAG SCREWS @ 4" in O.C. FROM EA. COLUMN & 16" (2) 2" X 8" W/ 1/2" COX STAGGERED CENTERS THRU FLITCH PLATE HEADER SHOWER SIN K STRAPPED TO THE JACK o 0 0 STUDS W/ SIMPSON rj LSTA18 STRAPS W/ (14) 10d NAILS (7 EA. SIDE) m 0 +32/42 PSF m R-13 INSULATION 15'-4" 2'-3" 2" X 4" WOOD STUD WALL 16" O.C. W/ HARDI-PANEL SIDING OVER 1/2" COX 1/2" GYP. BD. DRYWALL NOTE: ALL DIMENSIONS SHEATHING Wl8d NAILS @ 6" O.C. AT FLOOR FRAMING PLAN TO BE VERIFIED IN FIELD THE EDGES & 10" O.C. IN THE FIELD y/ SCALE: 1/4" = 1'-0" HARDI-PANEL SIDING, SEE FLORIDA 2" X 4" PT #2 SYP BOTTOM PLATE C _ TY Bl PRODUCT APPROVAL INSTALLATION ATTACHED W/ 1/2" WEDGE ST. LL' I C LTA" BIZLDI`:G E,T"�^EON INSTRUCTIONS (FL 13192.2) ANCHOR gEVIE I FO hC iZEVIENE B � ' NEW 4" THICK CONCRETE FLOOR SLAB, 3,000 'DATE SIMPSON SP4 @ 32" O.C. @ BOTTOM P.S.I. MIN. WITH TROWEL SMOOTH FINISH %I,puTS 'VD %ERIIIT MUST BE KEPT ON JOB #4 X 1IN BAR DOWEL &EPDXY 4 INTO REINFORCED WITH 6" X 6" - W1.4AN1.4 W.W. MESH Q is�J ;a;SPECTION WILL BE HiADB" EXISTING FOOTING/SLAB & @ 24" O.C. OR FIBER MESH W/ 6 MIL VAPOR BARRIER ON --f COMPACTED TREATED SOIL -BROOM FINISH EXISTING FOUNDATION L AND SLAB TO REMAIN 9 0 16" X 12" CONC. FOOTING W/ (2) #5 V-4" I DOWEL & EPDXY (2) #5 X 36" BARS 6" BARS CONT. INTO EXISTING FOUNDATION (30" LAP SPLICE)(EA. SIDE WHERE NEW FOUNDATION MEETS OLD) WALL SECTION SCALE: 3/4" = V-0" NEW BATHROOM ADDITI FOUNDATION PLAN SCALE.: 1/4" = 1'-0" Ln E iu m U pM 0 f0 U ) N O mmN P E d m� V) rn 04 tiMLLIM W N�1-ik Z N f p m 1 CL��wa (� ar-u)�U 4-1 0 a co N M N M LL V / M -oo (p N v LL > C7 ul m ® L U Q U 2 am iu a O E OD > v IL SEAT 0` • .10°. �Iy i LL 00 3 u W -w 6 z C i' E E'ga "2Br ® ai co W N O N 0 W F 5 1n U) a W tY I- W W (� I W co On J Ln Rt VO1 LU 00 M ❑ z a p iLL g a W W_ 0_ H W m O 0 In ua¢ 0 c: Q �y J W ❑ Z ❑ W v O I✓ = z O J cn O w r .Gz NWi WN 4�(5 �z PROJ. NO. 17-4840 DATE 03/07/2018 SHEET NO. SHEET 1 OF 2