HomeMy WebLinkAboutNOA; Planks & Panels Fiber Cement Siding and SoffitMIAMI•DADE MJAMI DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.goy/economy
James Hardie Building Product, Inc.
10901 Elm Avenue
Fontana, CA 92337
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested' for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: "Hardie", "Cem" and "Prevail" Planks and Panels Fiber Cement Siding and Soffit
APPROVAL DOCUMENT: Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail
Panel; HardiePlank, CemPlank Prevail .Lap Siding; HardieSofftt, CemSoffit Panel; Installation Details
Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated 04/24/2013, prepared by the
manufacturer, signed and sealed by Ronald I. Ogawa, P.E., bearing the Miami -Dade County Product
Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade
County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: A permanent label with the manufacturer's name or logo, Plant City, Florida, and the
following statements: "ASTM C 1186 Type A compliant" and "Miami -Dade County Product Control
Approved" is to be located on each siding plank or panel and per FBC 1710.9.2 and 1710.9.3 on soffit
panels.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA 915-0122.04 and consists of this page 1 and evidence page E-1, as well as
approval document mentioned above.
The submitted documentation was reviewed by Carlos M.
ruarn oaoe coutvnr Utre�P.E.
�_-,
�� OA No. 17-0406.06
APPROVED L_xpirlion Date: May 1, 2022
Approval.Date: May 4, 2017
*12t,�,�Jzo
t% Page 1
James Hardie Building Products, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS "Submitted under NOA # 13-0311.07"
1. Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel;
HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel;
Installation Details Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated
04/24/2013, prepared by the manufacturer, signed and sealed by Ronald I. Ogawa,
P.E.
B. TESTS "Submitted under NOA # 13-0311.07"
1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of HardiePlank, HardieSoffit
and HardiePariel, prepared by Intertek Testing Services NA LTD, Test Report No.
100733361COQ-004, dated 08/24/2012, with revision 1 dated 04/25/2013, signed and
sealed by Rick Curkeet, P.E.
"Submitted under NOA. # 02-0729.02"
Laboratory Report Test
Date
Signature
2.
ATI-16423-1 PA 202 & 203
03/18/96
A. N. Reeves P.E.
3.
ATI 16423-2 PA 202 & 203
03/18/96.
A. N. Reeves P.E.
4.
AT! 16423-3 PA 202 & 203
03/18/96
A. N. Reeves P.E.
C. CALCULATIONS
1.
None.
D. QUALITY ASSURANCE
1.
Miami -Dade Department of Regulatory and Economic
Resources•(RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS "Submitted under NOA # 15-0122.04"
1. Statement letter of code conformance to the 5"' edition (2014) FBC issued by Ronald
I.Ogawa & Associates, Inc., dated 10/26/2014, signed and sealed by Ronald I.
Ogawa, P.E.
%0�4 r2,7701
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No. 17-0406.06
Expiration Date: May 1, 2022
Approval Date: May 4, 2017
E-1
PROD
as cam
Buildini
NOA-Ni
.l
.I
WALL
HEIGHT
I
i
UCT RENEWED
plying with the Florida
l Code
>. . 17-0406.06
Expiration te05/01/2022
By gZL A
Miami -Da a Product Control
WALLLENGT SEE
Stud Spadng at 16" 0.C. DETAIL A
/�~� 518"t1ck16ply APA rated
plywaod sheathing in
amodance with Florida
Build -rig Code Section
123223
i . e j ! ILWarr-resistive
J7
barrier per Florida
a
Building Code
Section 1404.2
X X 4" S-P-F
_ ! Wood Studs
B [-
Naiis at 16" Q.G. (typ.)
3/8" Minimum Edge Distance
Sheathing fastener, as described in
Note 1
Panel fastener, as described in
Note 2
HardiePanei, Cempanel,
Prevail Panel Siding
Water -resistive barrier per
Florida Building Code Section
1404.2
518" thick 15 ply APA rated
plywood sheathing fastened in
accordance with Florida Building
Code Section 2322.3
2" X 4" S-P-F Wood Studs
The wall and soffit frames are to be designed
by the Architect or Engineer of Record in
compliance with the Florida Building Code.
PROQU_C_P DE_SC- 1�P7�OIS
HardiePanei®. Cernpanelc$7, &
Prevail® Panel Siding materials are
nonasbestos fiber -cement products
tested in accordance with ASTM
C1186 Grade 11, Type Aand meeting
the requirements ofthe Ficidda
Building Code.
,PAMIEL DAMM-N S,t0�1S
Width Length Thickness
4 8.9,10, 5/16,
.QK$IGN PRE3S119-F-MTING
Installation design Pressure
Wood Studs -76 psf
i HardiePanei, Impact Resistant-
SECi10 JLB_B H.,di el, Planks installed over 518" thick / `a ply
CempPfva;i Panel APA rated plywood sheathing
Siding
iAR11iF�NS0.}Ca ltdlPAN V��PF2 1/A1L?ANELSID�G1NSrALFla_T10F1 —, All,.S
■ All installation shell be done in coninrmance with this Notice of Acceptance, the manufaoturee's
ins>allation recommendations, and the 3ppliczble sections of the Florida Building Code.
a Wood studs where HardiePanei, Gempanel, isrevail Panel Siding will be installed shall be .
designed by an Engineer or Architect per the Plotida Building Code and the requirements of this
N.OA
■ Mote 1] 518" thick/ 5 ply APA rated plywood sheathing shalt be attached #o the studs in
accordance with Florida Building Code Section 2322.3.
■ The siding panels shall be installed over 5/8" thick 16 ply APA rated plywood sheathing suppartec
by a minimum of 2"X4' S-P.F wood studs spaced a maximum of 16" 0.C.
• LNote 21 The Siding panel fastener shall be a 2" long, 0.=' head diameter, o.092' shank
diameter, corrosion resistant siding nail; the fasteners shall be spaced atV' O.C. at panel edges
and intermediate studs; the fasteners shall be driven through the 5/8" thick15 ply APA rated
plywood sheathing into wood studs located at 16" O.C.
• Fasteners shall have a minimum edge distance of $18" and a minimum clearance of 2" from
comers.
HARDIEPANEL, CEMPANEL PREVAIL PANEL
INSTALLATION DETAILS WOOL) SCUD CONSTRUCTION
James Hardie Building Products, Inc.
10901 Elm Avenue
Fontana, CA 923377
A I i PNL-PL.K-,SOFF
Creator; E. Gonzales Iscni.E 1ffi" =1'-o" I Date:412412013 Isrtear 1 OF 12
Fastener Spacing per Florida
Building Code.Section 2322.3
• • • r
a vDw4v * with *e'FhN ib
Acaep 9W No -01 .
Dace 61
• l�oy Ptnduct OoaWra&
r • •
• ,°�
Fastener Spacing per Florida
Building Code Section 2322.3
i !
• PRODUCTs PRODUCT RENEWED
{, as complying with the Florida
f% Building Code
` NOA-Nb. 17-0406.06
Expiration e05101/2022
Myramr ProdnctCeutroa By
FRAMIN
• • \
STA
w D FCOf
Sin N
a
Cladding 11
Framing
Sheathing
•t
■ NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
WITH ntq i-ONNECTIO1Ed COMMON NAILS (2 PER TOP AND NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) ,
t30TTOM CN)
■ THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
BY THE ARCHITECT OR ENGINEER OF RECORD IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEATHING
y NOMINAL 5/8" THICK15 PLY APA RATED PLYWOOD
SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA
BUiLDNG CODE; SECTION 2322A
CLAD N—Ci
THE PANEL IS FASTENED WITH 2" LONG, 0,223" HEAD
DIAMETER, 0.09Z! SHANK DIAMETER, CORROSION
RESISTANT SIDING NAILS, PLACE NAILS B" O.C. AT
PANEL EDGES AND INTERMEDIATE STUDS Phnna 9(
Creator: E. Gonzales
HARDIEPANEL, CEMPANEL, PREVAIL PANEL
INSTALLATION DETAILS WOOD STUD CONSTRUCTION
James Hardie Building Products, Inc.
10901 Elm Avenue
Fontana, CA 92337
WE KSCM NO OWci NO
A PNL•PLK-SOFF
Cue V = T-0, pate: 4/24/2013 1 SHEET 2 OF 12
1
1
WALL
- Fkarida
M
PRODUCT RENEWED
as complying with the Florida
Building Code
NOA-No. 17-0406.06
Expiration D e05/01/2022
By
MlaM603de Product Control
WALL LENGTH
Stud Spacing at 16" 0. G.
W
316" Minimum
Distance Nails at t3" O.C. (typ.)
Sheathing fastener, as
described in Note 1.
Panel fastener, as described In
Note 2
HardiePanelS Siding
Water -resistive barrier per
Florida Building Code Section
1404.2
5/8" thick / 5 ply APA gated
plywood sheathing fastened
to metal studs as described
in Note 1.
209a, MIS" X 1.518" Metal C-stud
The wall and soffit frames are to be designed
by the Architect or Engineer of Record In
compliance With the Florida Building Code.
SEE
DETAIL A
�— 6/8" thick 15 ply APA rated
f plywood sheathing fastened
to metal studs as described
in Note 1
S rly-L N-BM13
Water -resistive
barrier per Florida
Building Code
Section i404.2
200a, 3-5/6" X 1-5/a"
Metal Gstud
iHardiePanel,
cempanel,
Prevail Panel
Siding
PRQ1!_Q a1=-R P7'i_QN_
HardiePanel®, CempenelS, & PI'VailO
Panel Siding materials are nonesbestos
fiber -cement products tested in
accordance with ASTM C1186 Grade 11,
Type Aand meeting the requirements of
the Florida Building Code.
nNFF[ D111 iL 1� �65_LO_N-s-
W,idth Length Thickness
V 8,9,10, 6/16"
AE_S_LG_N�R�s_suRE R9�1N�
Installation resign Pressure
Metal Studs -104 psf
Impact Resistant —
Panel installed over 518" thick / 5 ply
APA rated plywood sheathing
}iAl2plpANE_L�CEN3P�NEl_�PREVA�L PANEL SIDING 1NSgLI�IC1 +�1 DETAILS
■ All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's
installation recommendations, and the applicable sections of the Florida Building Code.
■ Metal studs where HardiePanel, Cempanel, Prevail Panel Siding will be installed shall be -
deslgned by an Engineer or Architect per the Florida Building Code and the requirements of this
N.O.A.
■ [Note 1] 5/8" thick 15 ply APA rated plywood sheathing shall be attached to metal studs at 5'00
at panel edges and all Intermediate supports using a No.8-18, 0.315" heed diameter x 1-114" long
bugle head screw
■ the Siding panels shall be installed over 518" think / 5 ply APA rated plywood sheathing
supported by a minimum 20ga, Nominal 3-5W X 1-518" Metal C-studs spaced a mwdmum of 16"
O.C.
■ [Note 2] The siding panel fastener shall be a minimum No. 8-18, 0.815" head diameter X 1-518"
long* ribbed bugle head screw (*or screw shall have at least 3 full threads penetrating metal
framing); the fasteners shall be spaced at 6" O.C. at panel edges and intermediate studs; the
fasteners shall be driven through the 5/8" thick / 5 ply APA rated plywood sheathing into metal
studs located at 16" Q.C.
Fasteners shall have a minimum edge distance of 318" and a minimum clearance of 2" from
corners.
HARDIEPANEL, CEMPANEL, PREVAIL PANEL
INSTALLATION DETAILS METAL STUD CONSTRUCTION
James Hardie Building Products, Inc:
10901 Elm Avenue
Fontana, CA 92337
SIZE FSCM NO I DM5 NV
A PNL-PLK-SOFF
Creator. E Gonzales IscaLs' 1/2" - 1--a- I Date: 4/24/2013 1SHEET 3 OF 12
PRODUCT RENEWED
as complying with the Florida
Building Code
NOA-No. 17-0406.06
T
Expiration te06/01/2022
6.00in.
sy
. PRODUCrREVLSM
weth1I*
ltcccp� Plo / n '311 lr
•spittslioale3opc F '%
g
I'
II
I' I
II
T
n. I I
II
I�
I•I
I
mmu.c't a�v15ED
'0'C<x*Yivqwith�e Fmezfa
�` �(S. d22
E13ANI1j-G
■ NOMINAL 20 GAUGE S-51T X 1-5/8" STEEL STUDS 16" O.C.
FASTENED WITH 5/a" WAFER HEAD SCREWS (2 PER TOP
AND BOTTOM CONNECTION)
• THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNEb
BY THE ARCHITECT OR ENGINEER OF RECORD IN
COMPLIANCEWITH THE FLORIDA BUILDING CODE
SHEA7HINC
■ NOMINAL 518" THICK 15 PLY APA RATED PLYWOOD
SHEATHING TO METAL STUDS AT 6" OC AT PANEL
EpGE$ AND ALL INTERMEDIATE SUPPORTS USING
NO.8-18, 0.315" HEAD DIAMETER 1-1W LONG BUGLE
HEAD SCREW
CLmnmq
THE PANEL IS FASTENED WITH NO.8-18, 0.315" HEAD
DIAMETER X 1-5/8 ° LONG CORROSION RESISTANT
RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT
LEAST 3 FULL THREADS, PENETRATING THE METAL
FRAMING), PLACE SCREWS 6" O.C. AT PANEL EDGES
AND INTERMEDIATE STUDS
,001n.
Gadding
Framing
I
II
I• I Sheathing
II
I•I
I,I I.I
I I I � I JIB/�liu�is�4
,,► i aGA
-a = STATE OF �, ,+
�I ' ON AL 1
FOR METAL FTH SND I$ OM AOTION AND GRAVITY LOAD APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FRE
NOT PART OF THESE
1
T
WALL
3/4" Minimum
DI_TA1 L A
WALL LENG7
I
Y I ade C,odlro)
Distanceails atIv, O.C.4.. itYp,)
-Sheathing fastener, as
described in Note 1
Siding fastener, as
'
described in Note 2
Sao YHN with INvila
1
Ain S
HardiePlank,
Cemplank, Prevail
Lap Siding
i'e+dn. C.'Aeltoi
f'
/ Water -resistive barrier
�\
per Florida Building
Code Section 1404.2
5/8" thick 15 ply APA rated
` --
-� plywood sheathing fastened
PRODUCT RENEWED
` in accordance with Florida
as complying with the Florida
Building Code Section
Building Code
2322.3
NOA-No. 17-0406.06
Expiration te0510112022
2„ X 4�' S-P-F Wood Studs
The wall and soffit frames are to be designed
By
by the Architect or Engineer of Record 1n
Miami a Product Control
comoliance with the Florida Building Code,
Sim
DETAIL A
thick /5 ply APA
d plywood
athing in
�rdance with
ida building Code
pgQDUGT DI"3CR i?T1ON.
HardiePlank®, Cemplank®, &
PrevallS Plank lap Siding materials
are nonasbeStos fiber -cement
products tested in accordance with
ASTM C1186 Grade 11, Type A and
meeting the requirements of the
Florida Building Code.
lion 2322.3 PAPIEL UjrA_M,5j N$
Water -resistive Widtd Length Thickness
barrier per Florida 59-1/2D 5116"
SuiON Code
Section 14042 DMlGN PRESSUR9- M74N0
211X4"S4F-F installation Design Pressure
Wood Studs Wood Studs -92 psf
Lap Siding Impact Resistant —
Flanks installed over 518" thick 15 ply
1-114" iaa X 5/15" APA rated plywood sheathing
thick starW strip
}►DBE=P_C�?C�CjwMPI �,HK, t'REVlE1L�A�_SjD�h1GJJS1'ALIATIOD�%'1
y AIt lnstailatton shall be done in conformance with #his Notice of Acceptance, the manutacturePs
Instalation recommendations, and the applicable sections of the Florida Building Code_
Wood studs where HardiePlank, Cemplank, Prevail i.ap Siding will be installed shalt be designed by an
Engineer or Architect per the Florida Building Code and the requirements of this N,O F
■ [Note 1� 5!$' thick / 5 ply APA rated plywood sheathing shall be attached to the studs in accordance
with Florida Building Code Section 2322.3.
k Planks shall be applied horizontally commencing from the bottom course of the wait with 1-1/4" wide
laps at the top of the plank such that the exposure area of each plank Is:5 8-1/4" vertically.
[Note 21 The siding fastener shall be a 2-1/2" long, 0.223" head diameter, 0.092" shank diameter,
corrosion -resistant siding nail; The siding is fastened S 8-114" O.C. vertically and 1£" O.C. horizontally;
fasteners are driven into wood studs through 5/8" thick / 5 ply APA rated plywood sheathing, fasteners
are placed in the: overlapping area approximately aW from the bottom edge of the overlapping plank.
= Vertical joints shall be placed over studs.
The planks shall be installed over 5/8" thick /5 ply APA rated plywood sheathing supported by a
minimum of 21IX4" S-P-F wood studs spaced a maximum of 16" O.C_
= Fasteners shall have a minimum edge distance of 3/6".
HARDIEPL.ANk, CEMPLANK, PREVAIL LAP SIDING
INSTALLATION DETAILS WOOD STUD CONSTRUCTION
James Hardie Building Products, Inc.
10901 Elm Avenue
Fontana, CA 92337
PML-PLK-SOFF
Creator; E. Gonzales scan 112" = 1'-0" , Date, 412-4/2013 IsHEET 5 OP 12
REV
Fastener Spacing per Florida
Building Code Section 2$22.3
•
PRODUCT RENEWED
as complying with the Florida
Building Code
_ NOA=No. 17-0406.06
0.75in- �- Expiration D e05/01/2022
f
-By
Miami-aMiarni-]Yadfi Product Control
as co noyksvra r,timFLamth
8»gldingi'a t
58� •' ;vr adePraasutC.oadeo$
y
--�'-i its
Fastener Spacing per Florida
Building Cade Section 2322.3
FLAMING
■ NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED
WITH 3;.1/2" 16d COMMON NAILS (2 PER TOP AND
SOTTOM CONNECTIOM
= THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
BY THE ARCHITECT OR ENGINEER OF R1=CORD IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEA'Yl�,hi4
■ NOMINAL 518" THICK / 5 PLY APA RATED. PLYWOOD
SHFATHING'FASTENI=D IN ACCORDANCE WITH FLORIDA
BUILDING CODE SECTION 2322,3
CIa4QD• - _
■ PLANKS.OVERI.AP 1-1W
■ THE EXPOSURE IS! 8-114"
■ THE PLANKS ARE FACE NAILED WITH 2-112" LONG, 0.223"
HEAD DIAMETER, 0.092" SHANK DIAMETER, CORROSION
RESISTANT sibING NA)LS,•PLACE0 3/4" UP FROM THE
BOTTOM EDGE: OF THE PLANK AT EACH STUD LOCATIOt
--16 in. OC---t Cladding
Framing
Sheathing
.1
^rftnnucra�vts�------ i +) ,t,��►i+4i'.n \:1D A .. _
as amwyinq� whh *0 F1n"
No 21
STATE OF
�. _figs •• .......• �G��iQ,
�f4NAL rill
FOR METAL AND WOOD STUDS, PROVISIONS FOR. DIAPHRAGM ACTION AND ��ifl`fYLOAD ARE
NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING
INSTALLATION DETAILS WOOD STUD CONSTRUCTION
James Hardie Sullding Products, [no.
10901 Elm Avenue
Fontana, CA 92337
A I I PNL-PLK-SOFF 11
Creator: E. Gonzales (SCALE 1" =1'-d" I Date:4/24/2013 ISHEET 6 OP 12
PRODl1
as toms
Building
NOA-No
Expiraft
By
Miami-0
H'
Stud Spacing at 16I" O,C. ALL
- - - --i - - �n__..__....
1 1
_--......_-- .......... . � —
-- _� 1 ^ --------- i
f
PALL
I
•�
i
i
i '
s
as oaag�'icg �visb idap�dacida
l
i,'
t¢6
Lit
� . (�/
t
EIGHT
1lf �t1tFa+octuctCaelrs�as! I E i �$- f
.�I I is f
r)AIA1 •ti Gin,
314" Minimum Edge Distance Nails at 16" O.C. (typ,)
DETAIL A
Sheathing fastener, as
described in Note 1
with rite Florida \1
fgoeepeQoss is- 012vX PA Siding fastener, as
jl described in Note 2
MNrni 1,or~td
HardiePlank,
Cemplank,
Prevail Lap Siding
Water -resistive
barrier per Florida
.�, Building Code
- section 1404.2
518" thick 15 ply APA rated
ICT RENEWED plywood sheathing fastened to
lying with the Florida metal studs as described iin.
Code Note 1
1 T-0406.06 _�
in 05/01/2022 209a, 3-6/8"X 1-SIT Metal C-stud
The wall and soffitframes are to be designed
by the Architect or Engineer of Record in
hdd Product control compliance with the Florida Building Code.
SEE
jLR_QQ 0T l7MSC 1P'CiQN .
)ETAIL A
HardiePlank®, CemplankO, and
—T'-5/8"
thick /5 ply APA
Prevail® Plank Lap Siding materials
I�
rated plywood
are nonasbestos fiber -cement
t�
sheathing fastened
products tested In accordance with
tometal studs as
to metal
ASTM C1186 Grade 11, Type A and
in Note 1
meeting the requirements of the
Florida Building Cods.
Water -resistive
=
barrier per Florida
PI..ANK_DIfffElT htS
~
i3ullding Code
Width Length Thickness
Section 1404.2
5 9-112" 12' 5/16"
\20ga, 3S14" X 1-518" DESIGN PRESSURE i�ATtNG
Metal Crstud Installation Design Pressure
HardiePlank, Metal Studs -92 psf
Cemplank, Prevail
CTEO Lap 9lding Impact Resistant -
g_g 1-11a° tall X 5116" Planks Installed over 5/8" thick / 5 ply
thick starter strip APA rated plywood sheathing
HARDiEPLANK�CMI?LANiC PRE1/AlL LAP 5tbij�G iN_S_`GA�I._P.710N DETAILS
■ All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's installation
recommendations, and the applicable sections of the Florida Building Code.
• Metal studs where HardiePlank, Cemplank, Prevail Lap Siding will be installed shall be designed by an
Engineer or Architect per the Florida Building Code and the requirements of this N.O.A.
■ tNote 1] 5/e" thick 15 ply APA rated plywood sheathing shall be attached to metal studs at 6"oe at panel
edges and all intermediate supports using a No.8-18, 0,316' head diameter 1-1/4" long bugle head screw
■ Planks shall be applied horizontally commencing from the bottom course of the wall with 1-1/4" wide laps at
the top of the plank such that the exposure area of each plank Is s 8-1/4" vertically.
• INote 2] The siding fastener shall be a minimum No. 8-18, 0,31:v" head diameter X 2-114" long* bugle head
screw over metal studs for screw shall have at least 3 full threads penetrating metal framing); The siding is
fastened S $-114" D.C. vertically and 16" O.C. horizontally; fasteners are driven into metal studs through 5/8"
thick 15 ply APA rated plywood sheathing, fasteners are placed in the overlapping area approximately 3/4'
from the bottom edge of the overlapping plank.
Vertical joints shall be placed over studs.
■ The planks shall be installed over 5/8" thick 15 ply APA rated plywood sheathing supported by a minimum
20ga, Nominal 3-518"X 1-5/8" Metal C-studs spaced a maximum of 16" O-C.
• Fasteners shall have a minimum edge distance of 318",
HARDiEPLANK, CEMPLANK, PREVAIL LAP SIDING
INSTALLATION DETAILS METAL STUD CONSTRUCTION
f 11 James Hardle Building Products, Inc.
® 10901 Elm Avenue
Fontana, CA 92337
Phone. 909-355-6800 size FSCM NO . DWG No
Fax 909-427-0634 A PNL-PLK SOFF
'Creator. E. Gonzales SCALE 1/2" a V-a" I Date: 4/24/2013 1sxeer 7 of 12
-�{ 8.00in. 18 in. OC Cladding
�I
6.00in_ ' _
• I � Framing
-_-•-----_� �_- :--•__-- ' I I 6.00in.0C ! Sheathing
PRODUCT RENEWED I�
as complying with the Florida
Building Code
NOA-No. 17-0406.06
•-�— Expiration D te05101/2022 '{
lay • I 1 Q,
Miami- a Product Control j qqq OGA
----.---- ------
n ,,�eq
fa C4moyks wim t!c Fk�a lnv M'Ith ft Fkuift e �`'•
$flg �AAL' \ •r
-- Ely I t
t 'O�y� : STATE OF
s8 25in. I I �: 40RI� ' N'
�A.1V11N_G-
NOMINAL 2D GAUGE 3 518" X ^I-5I8" STEEL STUDS 16"
O.C. FASTENED WITH 518" LONG RIBBED BUGLE HEAD
SCREWS (2 PER TOP AND BOTTOM. CONNECTION)
■ THE WALL AND SOFFIT FRAMES ARE TO 5E DESIGNED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEATFII G
• NOMINAL518" THICK/ 5 PLY APA RATED PLYWOOD
SHEATHING TO METAL STUBS AT 6" OC AT -PANEL
EDGES AND ALL INTERMEDIATE SUPPORTS USING A
NO.8-18, 0.315" HEAD DIAMETER 1-1/4- LONG BUGLE HARDIEPL.ANK, CEMPLANK, PREVAIL LAP SIDING
HEALS SCREW
cLA�bING_ INSTALLATION DETAILS METAL STUD CONSTRUCTION• PLANKS OVERLAP 1-114"
■ THE EXPOSURE IS 8-114 " James Hardie Buliding Products,.lnc.
S
r THE PLANKS ARE FASTENED WITH NO.8-18, 0.315" 10901 Elm Avenue
HEAD DIAMETER X 2-1/4" RX[
LONG CORROSION- Fontana, CA 92337
RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW
SHALL HAVE AT LEAST 3 FULL THREADS )thane: 909-356-6300 siz� aSCM No Dwo NO �
PENETRATING THE METAL FRAMING), PLACED 3/4' UP Pax 9o9-427-0634 A PNL-PLK SOFF 1
FROM THE BOTTOM EDGE OF THE PLANK AT EACH Creator. E. Gonzales SCALE �" = -o" Dare:4l24l2013 sr er
STUD LOCATION s OF 12
WALL
I �f
J
PRODUCT RENEWED
as complying with the Florida
Building Code
NOA-No. 17-0406.06
Expiration PateOS/01/2022
By
mil
01
WALL LENGTI E SEE �r�o_�ucr a�ctrt�>1
Stud Spacing at 18" O_C_ DETAIL A HardieSoffitm & Cemsof * materials are
134-1 nonasbestos fiber -cement products tested in
accordance with ASTM 01186 Grade 11, Type A
and meeting the requirements of the Florida
Building Code.
318" Minimum
SQFt:ITTIMEDiSION$
l 2" x 4" tudWidth Length Thlckness
i wood Studss 4'
j'I DESIGN 1?F_ 55U_L2 RATjNG
HardieSoffit, installation Deslgn Pressure
I• m Cesoffit Wood Studs -70 psf
SsCiIOX 8EB_
Nails 4" O.C. (typ.)pRaDuCT aevmED PRC ?I1Ci vls>up
■.ice eia Fburida
Distance ta caMplying with *t Florift gugdW& CEondiz;s Code ode
r7 t Xh"
gy
!RV 0*""061
W.)ulr P.AwCowd� P`aduet
Soffit fastener, as
described in Note 1
HardieSoffit, Cemsoffit
/J
Minimum TX 4" S-P-F Wood Studs
The wall and soffit frames are to be
designed by the Architect or
Engineer of Record in compliance
with the Florida Building Code.
bl6lir�._�.OGA,9�`
114 i � e
e
No. 4 21.
STATE or
........ 1�4
ijARD1E50 ,Zr=KS0_--FL1—M-
• All Installation shall be done In conformance with this Notice of Acceptance, the manufacturer's
Installation recommendations, and the applicable sections of the Florida Building Code.
■ Wood studs where HardieSoffit, Cemsoffit will be installed shall be designed by an Engineer or
Architect par the Florida Building Code and the requirements of this N.O.A.
■ The soffit shall be installed over minimum 2"X4" S-P-F wood studs spaced a maximum of 16" O.C.
■ [Note 11 The soffit fastener shall be a 2" tang, 0.223" head diameter, 0.092" shank diameter,
corrosion resistant siding nail; the fasteners shall be spaced at4" O.C. at panel edges and
intermediate studs, the fasteners shall be driven into wood studs located at 16" O' C.
■ Fasteners shall have a minimum edge distance of 318" and a minimum clearance of 2" from comers.
Creator: E. Gonzales
HARDIESOFFIT, CEMSOFFIT PANEL
INSTALLATION DETAILS WOOD STUD CONSTRUCTION
James Hardie Building Products, Inc.
709Q1 Elm Avenue
Fontana, CA 92337
No
A I I PNL-PLK-SOFF
112" a V-0" I bate: 4124/2013 1 sHEEr 9 OF 12
Cladding
Framing
p • f
PRODUCT RENEWED
as complying with the Florida 1-
Building Code
. •
NOA-No. 17-0406.06
Expiration Da e0510112022
By '
4.00iT1.i - Mia—m-TMO Product Control
/1/rr//ll",���r
Pxcxiucrssvls Pxoavcrr it j `f �.13GA�i/
a ye witL the Fkwi& as W=Oyi v wnh e& 1F1oab®x � 1�1r'
i O�Id[rtgto4e Buil>faagC.octc L \
AcAa�aeliv '4 wcoep�een2Wn C7f .�� �Li - .{ry.1
. .1� . FagvlrrAion neGc . ! �!O f % • N 4 1 2 I
r
. . A�ialtti pmAuel Gaaeol • &iiam' f�tac Pnottact �'oae�ril � v
STATE OF :
FRAL
NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED .
WITH 3-1/2" 16d COMMON NAILS (2 PER TOP AND BOTTOM FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
CONNECTION)
NOT PART OF THIS APPROVAL (MIDST PROVIDI ALTERNATE PROVISIONS FOR THESE LOADS)
THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY
THE ARCHITECT OR ENGIN5ER OF RECORD IN COMPLIANCE
WITH THE FLORIDA BUILDING CODE
THE SOFFIT IS FASTENED WITH 2' LONG, 0.223" HEAD
HARDIL•50FFITf CEMSOFFIT PANEL
DIAMETER, 0.092" SHANK DIAMETER, CORROSION
INSTALLATION DETAILS WDOD STUD CONSTRUCTION
RESISTANT SIDING NAILS, PLACE NAILS 4" O.C. AT PANEL
EDGES AND INTERMEDIATE STUDS
James Hardie Building Products, Ina
10901 Elm Avenue .
•
� - ,ii
-
Fontana, CA 92337
Phom 909-3$6-6300
SIZE FSCM NO DWC NO
Fox909-427-0634
A PNL-PLK SOFF
Creator: E. Gonzales
SCALE 1"=1`-0" Dale: 4/24/2013 SHEET 10 OF 12
—WALL LENGTH
Stud Sp�aadiinng� at 16" O.C.
?PRODUCT RENEWED
:as complying with the Florida
I Building Code
i i I i I j NOA-No. 17-0406.06
WALL�-
El HT j i { 1 Expiration
i I! By
Miami-Ddc
!_ i{ i ii 4i ill
.L . _.
(7QWL—A
W��
316' Minimum Edge Distance
112022
Nails at V O.G. (typ.)
t fastener, as
dbed in Note 1
Hardie3offit, Cemsoffit
i 20ga,3-5/6'� 1-5/8" (Metal C-stud
i The wail and soffit frames are to be
L— designed by the Architect or Engineer
of Record In compliance with the
Florida Building Code:
SEE 9RO_DUC pi: GS—Q -TIO-N
S
D>` EE A HardieSofft & Cemsoffl* materials
are nonasbestosfiber-cement products
tested In accordance with ASTM 01186
1 Grade II, TypeA and meeting the .
requirements of the Florida Building
Code.
20ga.3-51B"X1-518" I0FFITD_ifUtE�1SI0 5.
Nietai Gstud Width Length Th{clmess
4' 8' l:
rM- eSoffU_it, j}ESICN PRESS_i lE RA JN_G
Installation Design Pressure
I. Metal Studs 55 f
414
• SECTION B_B lt�2c?1Cti7Ci ��� \6,t+t _
i'>:2WVCi' REVISER US `W'npiyias wtid On JEloride
es oc� with tyre FbCri�
Buildxtrg
corbG =0=ft No 13�p3t I •G� i 12
Am00ftbe NMI, 1 e'vteafi .O17
'�r
�D' S UEOF
H Cpoacramos_��pR1DP 'o`,�
+s�0 ttt�l
BARA(_O_FFr[,._QElV[SQFEU-P_ANEL INSTAL I0kDETAiL_S
Installation shall be done in conformance with this Notice of Accepi���� L N arttl
Aand�!httufi{'ahufacturer s
installation recommendations, and the applicable sections of the Florlda Building Code.
n Metal studs where Hardie5ofit, Cemsoffit will be installed shall be designed by an Engineer or
Architect per the Florida Building Code and the requirements of this N.Q.k
x The soffit shall be installed over minimum 20ge, Nominal 3-5l6" X 1-5/8" Metal C-studs spared
a maximum of 16" O.C.
" [Note 11 The soffit fastener shall be a minimum No. 8-18, 0.3161 head diameter X 1-114" long*
ribbed bugle head screw (*or screw shall have at least 3 full threads penetrating metal
framing);the fasteners shalt be spaced at 6" O.C. at panel edges and intermediate studs; the
fasteners shall be driven into metal studs located at 16" O.C.
• Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of 2" from
comers.
Creator. E.•Gonzales
SIZE
scALE
HARDIESOFFIT, CEMSOFFIT PANEL
INSTALLATION DETAILS METALSTUD CONSTRUCTION
James Hardie Building Products, )no.
10901 Elm Avenue
Fontana, CA 92337
PNL-PLK-SOFF
V2" LA V-0" I Date; 4/24/2013 1 SHEFT 11 OF 12
BAotn.
is.001n,
Cladding
,
Framing
6.0oln.
PRODUCT RENEWED
REVISED
PRODr t
as complying with the Florida
Building Code
ag winacd&
Aped P S 1
Yi08WtbttFtori&
�i C-&
�!J p�alt/j�ii
NOA-No. 'I7-0406.06
Expiration 05/01/2022MIA
t
A�bm*140 �3 7
mod°
��F+i j�}j�A
I
By iyljffitl prodoocContaol �� '
Miami-DZdf Product Control t� 2
• '��ss�o�P�
FRAMING �'''--�,.�,,.:�►�'
a NOMINAL 20 GAUGE; 3-5/6" X 1.6/8" STI=EL STUDS 16" O.G.
FASTENED WITH 6/8" WAFER HEAD SCREWS (2 PER TOp FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
AND BOTTOM CONNECTION) NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
■ THE WALLAND SOFFIT FRAMES ARE TO BE DESIGNED "
BY THE ARCHITECT OR ENGINEER OF RECORD IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE
CJ ADDII41Z HARDIESOFFIT, CEMSOFFIT PANEL
THE SOFFIT IS FASTENED WITH NO.8-18, 0.315" HEAD INSTALLATION pETAILS METAL STUD CONSTRUCTION
DIAMEi•ERX 1-1/�4' LONG CORROSION RESISTANT RIBBED
BUGLE HEAD SCREWS (SCREW SHALL HAVE. AT LEAST 3 James Hardie Building Produots, Inc.
FULL THREADS PENETRATING THE METAL FRAMING), PLACE
SCREWS 5' O.C. AT PANEL EDGES AND INTERMEDIATE 10901. Elm Avenue
STUDS ® Fontana, CA 92337'
Phone: 909-355-6300 SIZ6 FSOM NO DWO NO RE
Fax 909:427-063�4 A PNL-PLK-SOFF 9
Creator: E. Gonzales sms 1" = d'-0" Date: 4/24/2013 smiF 12 OV 12