Loading...
HomeMy WebLinkAboutNOA; Planks & Panels Fiber Cement Siding and SoffitMIAMI•DADE MJAMI DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.goy/economy James Hardie Building Product, Inc. 10901 Elm Avenue Fontana, CA 92337 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested' for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: "Hardie", "Cem" and "Prevail" Planks and Panels Fiber Cement Siding and Soffit APPROVAL DOCUMENT: Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel; HardiePlank, CemPlank Prevail .Lap Siding; HardieSofftt, CemSoffit Panel; Installation Details Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated 04/24/2013, prepared by the manufacturer, signed and sealed by Ronald I. Ogawa, P.E., bearing the Miami -Dade County Product Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: A permanent label with the manufacturer's name or logo, Plant City, Florida, and the following statements: "ASTM C 1186 Type A compliant" and "Miami -Dade County Product Control Approved" is to be located on each siding plank or panel and per FBC 1710.9.2 and 1710.9.3 on soffit panels. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 915-0122.04 and consists of this page 1 and evidence page E-1, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. ruarn oaoe coutvnr Utre�P.E. �_-, �� OA No. 17-0406.06 APPROVED L_xpirlion Date: May 1, 2022 Approval.Date: May 4, 2017 *12t,�,�Jzo t% Page 1 James Hardie Building Products, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS "Submitted under NOA # 13-0311.07" 1. Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel; HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation Details Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated 04/24/2013, prepared by the manufacturer, signed and sealed by Ronald I. Ogawa, P.E. B. TESTS "Submitted under NOA # 13-0311.07" 1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of HardiePlank, HardieSoffit and HardiePariel, prepared by Intertek Testing Services NA LTD, Test Report No. 100733361COQ-004, dated 08/24/2012, with revision 1 dated 04/25/2013, signed and sealed by Rick Curkeet, P.E. "Submitted under NOA. # 02-0729.02" Laboratory Report Test Date Signature 2. ATI-16423-1 PA 202 & 203 03/18/96 A. N. Reeves P.E. 3. ATI 16423-2 PA 202 & 203 03/18/96. A. N. Reeves P.E. 4. AT! 16423-3 PA 202 & 203 03/18/96 A. N. Reeves P.E. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources•(RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS "Submitted under NOA # 15-0122.04" 1. Statement letter of code conformance to the 5"' edition (2014) FBC issued by Ronald I.Ogawa & Associates, Inc., dated 10/26/2014, signed and sealed by Ronald I. Ogawa, P.E. %0�4 r2,7701 Carlos M. Utrera, P.E. Product Control Examiner NOA No. 17-0406.06 Expiration Date: May 1, 2022 Approval Date: May 4, 2017 E-1 PROD as cam Buildini NOA-Ni .l .I WALL HEIGHT I i UCT RENEWED plying with the Florida l Code >. . 17-0406.06 Expiration te05/01/2022 By gZL A Miami -Da a Product Control WALLLENGT SEE Stud Spadng at 16" 0.C. DETAIL A /�~� 518"t1ck16ply APA rated plywaod sheathing in amodance with Florida Build -rig Code Section 123223 i . e j ! ILWarr-resistive J7 barrier per Florida a Building Code Section 1404.2 X X 4" S-P-F _ ! Wood Studs B [- Naiis at 16" Q.G. (typ.) 3/8" Minimum Edge Distance Sheathing fastener, as described in Note 1 Panel fastener, as described in Note 2 HardiePanei, Cempanel, Prevail Panel Siding Water -resistive barrier per Florida Building Code Section 1404.2 518" thick 15 ply APA rated plywood sheathing fastened in accordance with Florida Building Code Section 2322.3 2" X 4" S-P-F Wood Studs The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code. PROQU_C_P DE_SC- 1�P7�OIS HardiePanei®. Cernpanelc$7, & Prevail® Panel Siding materials are nonasbestos fiber -cement products tested in accordance with ASTM C1186 Grade 11, Type Aand meeting the requirements ofthe Ficidda Building Code. ,PAMIEL DAMM-N S,t0�1S Width Length Thickness 4 8.9,10, 5/16, .QK$IGN PRE3S119-F-MTING Installation design Pressure Wood Studs -76 psf i HardiePanei, Impact Resistant- SECi10 JLB_B H.,di el, Planks installed over 518" thick / `a ply CempPfva;i Panel APA rated plywood sheathing Siding iAR11iF�NS0.}Ca ltdlPAN V��PF2 1/A1L?ANELSID�G1NSrALFla_T10F1 —, All,.S ■ All installation shell be done in coninrmance with this Notice of Acceptance, the manufaoturee's ins>allation recommendations, and the 3ppliczble sections of the Florida Building Code. a Wood studs where HardiePanei, Gempanel, isrevail Panel Siding will be installed shall be . designed by an Engineer or Architect per the Plotida Building Code and the requirements of this N.OA ■ Mote 1] 518" thick/ 5 ply APA rated plywood sheathing shalt be attached #o the studs in accordance with Florida Building Code Section 2322.3. ■ The siding panels shall be installed over 5/8" thick 16 ply APA rated plywood sheathing suppartec by a minimum of 2"X4' S-P.F wood studs spaced a maximum of 16" 0.C. • LNote 21 The Siding panel fastener shall be a 2" long, 0.=' head diameter, o.092' shank diameter, corrosion resistant siding nail; the fasteners shall be spaced atV' O.C. at panel edges and intermediate studs; the fasteners shall be driven through the 5/8" thick15 ply APA rated plywood sheathing into wood studs located at 16" O.C. • Fasteners shall have a minimum edge distance of $18" and a minimum clearance of 2" from comers. HARDIEPANEL, CEMPANEL PREVAIL PANEL INSTALLATION DETAILS WOOL) SCUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 923377 A I i PNL-PL.K-,SOFF Creator; E. Gonzales Iscni.E 1ffi" =1'-o" I Date:412412013 Isrtear 1 OF 12 Fastener Spacing per Florida Building Code.Section 2322.3 • • • r a vDw4v * with *e'FhN ib Acaep 9W No -01 . Dace 61 • l�oy Ptnduct OoaWra& r • • • ,°� Fastener Spacing per Florida Building Code Section 2322.3 i ! • PRODUCTs PRODUCT RENEWED {, as complying with the Florida f% Building Code ` NOA-Nb. 17-0406.06 Expiration e05101/2022 Myramr ProdnctCeutroa By FRAMIN • • \ STA w D FCOf Sin N a Cladding 11 Framing Sheathing •t ■ NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE WITH ntq i-ONNECTIO1Ed COMMON NAILS (2 PER TOP AND NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) , t30TTOM CN) ■ THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING y NOMINAL 5/8" THICK15 PLY APA RATED PLYWOOD SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA BUiLDNG CODE; SECTION 2322A CLAD N—Ci THE PANEL IS FASTENED WITH 2" LONG, 0,223" HEAD DIAMETER, 0.09Z! SHANK DIAMETER, CORROSION RESISTANT SIDING NAILS, PLACE NAILS B" O.C. AT PANEL EDGES AND INTERMEDIATE STUDS Phnna 9( Creator: E. Gonzales HARDIEPANEL, CEMPANEL, PREVAIL PANEL INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 WE KSCM NO OWci NO A PNL•PLK-SOFF Cue V = T-0, pate: 4/24/2013 1 SHEET 2 OF 12 1 1 WALL - Fkarida M PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 Expiration D e05/01/2022 By MlaM603de Product Control WALL LENGTH Stud Spacing at 16" 0. G. W 316" Minimum Distance Nails at t3" O.C. (typ.) Sheathing fastener, as described in Note 1. Panel fastener, as described In Note 2 HardiePanelS Siding Water -resistive barrier per Florida Building Code Section 1404.2 5/8" thick / 5 ply APA gated plywood sheathing fastened to metal studs as described in Note 1. 209a, MIS" X 1.518" Metal C-stud The wall and soffit frames are to be designed by the Architect or Engineer of Record In compliance With the Florida Building Code. SEE DETAIL A �— 6/8" thick 15 ply APA rated f plywood sheathing fastened to metal studs as described in Note 1 S rly-L N-BM13 Water -resistive barrier per Florida Building Code Section i404.2 200a, 3-5/6" X 1-5/a" Metal Gstud iHardiePanel, cempanel, Prevail Panel Siding PRQ1!_Q a1=-R P7'i_QN_ HardiePanel®, CempenelS, & PI'VailO Panel Siding materials are nonesbestos fiber -cement products tested in accordance with ASTM C1186 Grade 11, Type Aand meeting the requirements of the Florida Building Code. nNFF[ D111 iL 1� �65_LO_N-s- W,idth Length Thickness V 8,9,10, 6/16" AE_S_LG_N�R�s_suRE R9�1N� Installation resign Pressure Metal Studs -104 psf Impact Resistant — Panel installed over 518" thick / 5 ply APA rated plywood sheathing }iAl2plpANE_L�CEN3P�NEl_�PREVA�L PANEL SIDING 1NSgLI�IC1 +�1 DETAILS ■ All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's installation recommendations, and the applicable sections of the Florida Building Code. ■ Metal studs where HardiePanel, Cempanel, Prevail Panel Siding will be installed shall be - deslgned by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. ■ [Note 1] 5/8" thick 15 ply APA rated plywood sheathing shall be attached to metal studs at 5'00 at panel edges and all Intermediate supports using a No.8-18, 0.315" heed diameter x 1-114" long bugle head screw ■ the Siding panels shall be installed over 518" think / 5 ply APA rated plywood sheathing supported by a minimum 20ga, Nominal 3-5W X 1-518" Metal C-studs spaced a mwdmum of 16" O.C. ■ [Note 2] The siding panel fastener shall be a minimum No. 8-18, 0.815" head diameter X 1-518" long* ribbed bugle head screw (*or screw shall have at least 3 full threads penetrating metal framing); the fasteners shall be spaced at 6" O.C. at panel edges and intermediate studs; the fasteners shall be driven through the 5/8" thick / 5 ply APA rated plywood sheathing into metal studs located at 16" Q.C. Fasteners shall have a minimum edge distance of 318" and a minimum clearance of 2" from corners. HARDIEPANEL, CEMPANEL, PREVAIL PANEL INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Products, Inc: 10901 Elm Avenue Fontana, CA 92337 SIZE FSCM NO I DM5 NV A PNL-PLK-SOFF Creator. E Gonzales IscaLs' 1/2" - 1--a- I Date: 4/24/2013 1SHEET 3 OF 12 PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 T Expiration te06/01/2022 6.00in. sy . PRODUCrREVLSM weth1I* ltcccp� Plo / n '311 lr •spittslioale3opc F '% g I' II I' I II T n. I I II I� I•I I mmu.c't a�v15ED '0'C<x*Yivqwith�e Fmezfa �` �(S. d22 E13ANI1j-G ■ NOMINAL 20 GAUGE S-51T X 1-5/8" STEEL STUDS 16" O.C. FASTENED WITH 5/a" WAFER HEAD SCREWS (2 PER TOP AND BOTTOM CONNECTION) • THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNEb BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCEWITH THE FLORIDA BUILDING CODE SHEA7HINC ■ NOMINAL 518" THICK 15 PLY APA RATED PLYWOOD SHEATHING TO METAL STUDS AT 6" OC AT PANEL EpGE$ AND ALL INTERMEDIATE SUPPORTS USING NO.8-18, 0.315" HEAD DIAMETER 1-1W LONG BUGLE HEAD SCREW CLmnmq THE PANEL IS FASTENED WITH NO.8-18, 0.315" HEAD DIAMETER X 1-5/8 ° LONG CORROSION RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 FULL THREADS, PENETRATING THE METAL FRAMING), PLACE SCREWS 6" O.C. AT PANEL EDGES AND INTERMEDIATE STUDS ,001n. Gadding Framing I II I• I Sheathing II I•I I,I I.I I I I � I JIB/�liu�is�4 ,,► i aGA -a = STATE OF �, ,+ �I ' ON AL 1 FOR METAL FTH SND I$ OM AOTION AND GRAVITY LOAD APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FRE NOT PART OF THESE 1 T WALL 3/4" Minimum DI_TA1 L A WALL LENG7 I Y I ade C,odlro) Distanceails atIv, O.C.4.. itYp,) -Sheathing fastener, as described in Note 1 Siding fastener, as ' described in Note 2 Sao YHN with INvila 1 Ain S HardiePlank, Cemplank, Prevail Lap Siding i'e+dn. C.'Aeltoi f' / Water -resistive barrier �\ per Florida Building Code Section 1404.2 5/8" thick 15 ply APA rated ` -- -� plywood sheathing fastened PRODUCT RENEWED ` in accordance with Florida as complying with the Florida Building Code Section Building Code 2322.3 NOA-No. 17-0406.06 Expiration te0510112022 2„ X 4�' S-P-F Wood Studs The wall and soffit frames are to be designed By by the Architect or Engineer of Record 1n Miami a Product Control comoliance with the Florida Building Code, Sim DETAIL A thick /5 ply APA d plywood athing in �rdance with ida building Code pgQDUGT DI"3CR i?T1ON. HardiePlank®, Cemplank®, & PrevallS Plank lap Siding materials are nonasbeStos fiber -cement products tested in accordance with ASTM C1186 Grade 11, Type A and meeting the requirements of the Florida Building Code. lion 2322.3 PAPIEL UjrA_M,5j N$ Water -resistive Widtd Length Thickness barrier per Florida 59-1/2D 5116" SuiON Code Section 14042 DMlGN PRESSUR9- M74N0 211X4"S4F-F installation Design Pressure Wood Studs Wood Studs -92 psf Lap Siding Impact Resistant — Flanks installed over 518" thick 15 ply 1-114" iaa X 5/15" APA rated plywood sheathing thick starW strip }►DBE=P_C�?C�CjwMPI �,HK, t'REVlE1L�A�_SjD�h1GJJS1'ALIATIOD�%'1 y AIt lnstailatton shall be done in conformance with #his Notice of Acceptance, the manutacturePs Instalation recommendations, and the applicable sections of the Florida Building Code_ Wood studs where HardiePlank, Cemplank, Prevail i.ap Siding will be installed shalt be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N,O F ■ [Note 1� 5!$' thick / 5 ply APA rated plywood sheathing shall be attached to the studs in accordance with Florida Building Code Section 2322.3. k Planks shall be applied horizontally commencing from the bottom course of the wait with 1-1/4" wide laps at the top of the plank such that the exposure area of each plank Is:5 8-1/4" vertically. [Note 21 The siding fastener shall be a 2-1/2" long, 0.223" head diameter, 0.092" shank diameter, corrosion -resistant siding nail; The siding is fastened S 8-114" O.C. vertically and 1£" O.C. horizontally; fasteners are driven into wood studs through 5/8" thick / 5 ply APA rated plywood sheathing, fasteners are placed in the: overlapping area approximately aW from the bottom edge of the overlapping plank. = Vertical joints shall be placed over studs. The planks shall be installed over 5/8" thick /5 ply APA rated plywood sheathing supported by a minimum of 21IX4" S-P-F wood studs spaced a maximum of 16" O.C_ = Fasteners shall have a minimum edge distance of 3/6". HARDIEPL.ANk, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 PML-PLK-SOFF Creator; E. Gonzales scan 112" = 1'-0" , Date, 412-4/2013 IsHEET 5 OP 12 REV Fastener Spacing per Florida Building Code Section 2$22.3 • PRODUCT RENEWED as complying with the Florida Building Code _ NOA=No. 17-0406.06 0.75in- �- Expiration D e05/01/2022 f -By Miami-aMiarni-]Yadfi Product Control as co noyksvra r,timFLamth 8»gldingi'a t 58� •' ;vr adePraasutC.oadeo$ y --�'-i its Fastener Spacing per Florida Building Cade Section 2322.3 FLAMING ■ NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED WITH 3;.1/2" 16d COMMON NAILS (2 PER TOP AND SOTTOM CONNECTIOM = THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF R1=CORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEA'Yl�,hi4 ■ NOMINAL 518" THICK / 5 PLY APA RATED. PLYWOOD SHFATHING'FASTENI=D IN ACCORDANCE WITH FLORIDA BUILDING CODE SECTION 2322,3 CIa4QD• - _ ■ PLANKS.OVERI.AP 1-1W ■ THE EXPOSURE IS! 8-114" ■ THE PLANKS ARE FACE NAILED WITH 2-112" LONG, 0.223" HEAD DIAMETER, 0.092" SHANK DIAMETER, CORROSION RESISTANT sibING NA)LS,•PLACE0 3/4" UP FROM THE BOTTOM EDGE: OF THE PLANK AT EACH STUD LOCATIOt --16 in. OC---t Cladding Framing Sheathing .1 ^rftnnucra�vts�------ i +) ,t,��►i+4i'.n \:1D A .. _ as amwyinq� whh *0 F1n" No 21 STATE OF �. _figs •• .......• �G��iQ, �f4NAL rill FOR METAL AND WOOD STUDS, PROVISIONS FOR. DIAPHRAGM ACTION AND ��ifl`fYLOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Sullding Products, [no. 10901 Elm Avenue Fontana, CA 92337 A I I PNL-PLK-SOFF 11 Creator: E. Gonzales (SCALE 1" =1'-d" I Date:4/24/2013 ISHEET 6 OP 12 PRODl1 as toms Building NOA-No Expiraft By Miami-0 H' Stud Spacing at 16I" O,C. ALL - - - --i - - �n__..__.... 1 1 _--......_-- .......... . � — -- _� 1 ^ --------- i f PALL I •� i i i ' s as oaag�'icg �visb idap�dacida l i,' t¢6 Lit � . (�/ t EIGHT 1lf �t1tFa+octuctCaelrs�as! I E i �$- f .�I I is f r)AIA1 •ti Gin, 314" Minimum Edge Distance Nails at 16" O.C. (typ,) DETAIL A Sheathing fastener, as described in Note 1 with rite Florida \1 fgoeepeQoss is- 012vX PA Siding fastener, as jl described in Note 2 MNrni 1,or~td HardiePlank, Cemplank, Prevail Lap Siding Water -resistive barrier per Florida .�, Building Code - section 1404.2 518" thick 15 ply APA rated ICT RENEWED plywood sheathing fastened to lying with the Florida metal studs as described iin. Code Note 1 1 T-0406.06 _� in 05/01/2022 209a, 3-6/8"X 1-SIT Metal C-stud The wall and soffitframes are to be designed by the Architect or Engineer of Record in hdd Product control compliance with the Florida Building Code. SEE jLR_QQ 0T l7MSC 1P'CiQN . )ETAIL A HardiePlank®, CemplankO, and —T'-5/8" thick /5 ply APA Prevail® Plank Lap Siding materials I� rated plywood are nonasbestos fiber -cement t� sheathing fastened products tested In accordance with tometal studs as to metal ASTM C1186 Grade 11, Type A and in Note 1 meeting the requirements of the Florida Building Cods. Water -resistive = barrier per Florida PI..ANK_DIfffElT htS ~ i3ullding Code Width Length Thickness Section 1404.2 5 9-112" 12' 5/16" \20ga, 3S14" X 1-518" DESIGN PRESSURE i�ATtNG Metal Crstud Installation Design Pressure HardiePlank, Metal Studs -92 psf Cemplank, Prevail CTEO Lap 9lding Impact Resistant - g_g 1-11a° tall X 5116" Planks Installed over 5/8" thick / 5 ply thick starter strip APA rated plywood sheathing HARDiEPLANK�CMI?LANiC PRE1/AlL LAP 5tbij�G iN_S_`GA�I._P.710N DETAILS ■ All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's installation recommendations, and the applicable sections of the Florida Building Code. • Metal studs where HardiePlank, Cemplank, Prevail Lap Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. ■ tNote 1] 5/e" thick 15 ply APA rated plywood sheathing shall be attached to metal studs at 6"oe at panel edges and all intermediate supports using a No.8-18, 0,316' head diameter 1-1/4" long bugle head screw ■ Planks shall be applied horizontally commencing from the bottom course of the wall with 1-1/4" wide laps at the top of the plank such that the exposure area of each plank Is s 8-1/4" vertically. • INote 2] The siding fastener shall be a minimum No. 8-18, 0,31:v" head diameter X 2-114" long* bugle head screw over metal studs for screw shall have at least 3 full threads penetrating metal framing); The siding is fastened S $-114" D.C. vertically and 16" O.C. horizontally; fasteners are driven into metal studs through 5/8" thick 15 ply APA rated plywood sheathing, fasteners are placed in the overlapping area approximately 3/4' from the bottom edge of the overlapping plank. Vertical joints shall be placed over studs. ■ The planks shall be installed over 5/8" thick 15 ply APA rated plywood sheathing supported by a minimum 20ga, Nominal 3-518"X 1-5/8" Metal C-studs spaced a maximum of 16" O-C. • Fasteners shall have a minimum edge distance of 318", HARDiEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS METAL STUD CONSTRUCTION f 11 James Hardle Building Products, Inc. ® 10901 Elm Avenue Fontana, CA 92337 Phone. 909-355-6800 size FSCM NO . DWG No Fax 909-427-0634 A PNL-PLK SOFF 'Creator. E. Gonzales SCALE 1/2" a V-a" I Date: 4/24/2013 1sxeer 7 of 12 -�{ 8.00in. 18 in. OC Cladding �I 6.00in_ ' _ • I � Framing -_-•-----_� �_- :--•__-- ' I I 6.00in.0C ! Sheathing PRODUCT RENEWED I� as complying with the Florida Building Code NOA-No. 17-0406.06 •-�— Expiration D te05101/2022 '{ lay • I 1 Q, Miami- a Product Control j qqq OGA ----.---- ------ n ,,�eq fa C4moyks wim t!c Fk�a lnv M'Ith ft Fkuift e �`'• $flg �AAL' \ •r -- Ely I t t 'O�y� : STATE OF s8 25in. I I �: 40RI� ' N' �A.1V11N_G- NOMINAL 2D GAUGE 3 518" X ^I-5I8" STEEL STUDS 16" O.C. FASTENED WITH 518" LONG RIBBED BUGLE HEAD SCREWS (2 PER TOP AND BOTTOM. CONNECTION) ■ THE WALL AND SOFFIT FRAMES ARE TO 5E DESIGNED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATFII G • NOMINAL518" THICK/ 5 PLY APA RATED PLYWOOD SHEATHING TO METAL STUBS AT 6" OC AT -PANEL EDGES AND ALL INTERMEDIATE SUPPORTS USING A NO.8-18, 0.315" HEAD DIAMETER 1-1/4- LONG BUGLE HARDIEPL.ANK, CEMPLANK, PREVAIL LAP SIDING HEALS SCREW cLA�bING_ INSTALLATION DETAILS METAL STUD CONSTRUCTION• PLANKS OVERLAP 1-114" ■ THE EXPOSURE IS 8-114 " James Hardie Buliding Products,.lnc. S r THE PLANKS ARE FASTENED WITH NO.8-18, 0.315" 10901 Elm Avenue HEAD DIAMETER X 2-1/4" RX[ LONG CORROSION- Fontana, CA 92337 RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 FULL THREADS )thane: 909-356-6300 siz� aSCM No Dwo NO � PENETRATING THE METAL FRAMING), PLACED 3/4' UP Pax 9o9-427-0634 A PNL-PLK SOFF 1 FROM THE BOTTOM EDGE OF THE PLANK AT EACH Creator. E. Gonzales SCALE �" = -o" Dare:4l24l2013 sr er STUD LOCATION s OF 12 WALL I �f J PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 Expiration PateOS/01/2022 By mil 01 WALL LENGTI E SEE �r�o_�ucr a�ctrt�>1 Stud Spacing at 18" O_C_ DETAIL A HardieSoffitm & Cemsof * materials are 134-1 nonasbestos fiber -cement products tested in accordance with ASTM 01186 Grade 11, Type A and meeting the requirements of the Florida Building Code. 318" Minimum SQFt:ITTIMEDiSION$ l 2" x 4" tudWidth Length Thlckness i wood Studss 4' j'I DESIGN 1?F_ 55U_L2 RATjNG HardieSoffit, installation Deslgn Pressure I• m Cesoffit Wood Studs -70 psf SsCiIOX 8EB_ Nails 4" O.C. (typ.)pRaDuCT aevmED PRC ?I1Ci vls>up ■.ice eia Fburida Distance ta caMplying with *t Florift gugdW& CEondiz;s Code ode r7 t Xh" gy !RV 0*""061 W.)ulr P.AwCowd� P`aduet Soffit fastener, as described in Note 1 HardieSoffit, Cemsoffit /J Minimum TX 4" S-P-F Wood Studs The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code. bl6lir�._�.OGA,9�` 114 i � e e No. 4 21. STATE or ........ 1�4 ijARD1E50 ,Zr=KS0_--FL1—M- • All Installation shall be done In conformance with this Notice of Acceptance, the manufacturer's Installation recommendations, and the applicable sections of the Florida Building Code. ■ Wood studs where HardieSoffit, Cemsoffit will be installed shall be designed by an Engineer or Architect par the Florida Building Code and the requirements of this N.O.A. ■ The soffit shall be installed over minimum 2"X4" S-P-F wood studs spaced a maximum of 16" O.C. ■ [Note 11 The soffit fastener shall be a 2" tang, 0.223" head diameter, 0.092" shank diameter, corrosion resistant siding nail; the fasteners shall be spaced at4" O.C. at panel edges and intermediate studs, the fasteners shall be driven into wood studs located at 16" O' C. ■ Fasteners shall have a minimum edge distance of 318" and a minimum clearance of 2" from comers. Creator: E. Gonzales HARDIESOFFIT, CEMSOFFIT PANEL INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, Inc. 709Q1 Elm Avenue Fontana, CA 92337 No A I I PNL-PLK-SOFF 112" a V-0" I bate: 4124/2013 1 sHEEr 9 OF 12 Cladding Framing p • f PRODUCT RENEWED as complying with the Florida 1- Building Code . • NOA-No. 17-0406.06 Expiration Da e0510112022 By ' 4.00iT1.i - Mia—m-TMO Product Control /1/rr//ll",���r Pxcxiucrssvls Pxoavcrr it j `f �.13GA�i/ a ye witL the Fkwi& as W=Oyi v wnh e& 1F1oab®x � 1�1r' i O�Id[rtgto4e Buil>faagC.octc L \ AcAa�aeliv '4 wcoep�een2Wn C7f .�� �Li - .{ry.1 . .1� . FagvlrrAion neGc . ! �!O f % • N 4 1 2 I r . . A�ialtti pmAuel Gaaeol • &iiam' f�tac Pnottact �'oae�ril � v STATE OF : FRAL NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED . WITH 3-1/2" 16d COMMON NAILS (2 PER TOP AND BOTTOM FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE CONNECTION) NOT PART OF THIS APPROVAL (MIDST PROVIDI ALTERNATE PROVISIONS FOR THESE LOADS) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGIN5ER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE THE SOFFIT IS FASTENED WITH 2' LONG, 0.223" HEAD HARDIL•50FFITf CEMSOFFIT PANEL DIAMETER, 0.092" SHANK DIAMETER, CORROSION INSTALLATION DETAILS WDOD STUD CONSTRUCTION RESISTANT SIDING NAILS, PLACE NAILS 4" O.C. AT PANEL EDGES AND INTERMEDIATE STUDS James Hardie Building Products, Ina 10901 Elm Avenue . • � - ,ii - Fontana, CA 92337 Phom 909-3$6-6300 SIZE FSCM NO DWC NO Fox909-427-0634 A PNL-PLK SOFF Creator: E. Gonzales SCALE 1"=1`-0" Dale: 4/24/2013 SHEET 10 OF 12 —WALL LENGTH Stud Sp�aadiinng� at 16" O.C. ?PRODUCT RENEWED :as complying with the Florida I Building Code i i I i I j NOA-No. 17-0406.06 WALL�- El HT j i { 1 Expiration i I! By Miami-Ddc !_ i{ i ii 4i ill .L . _. (7QWL—A W�� 316' Minimum Edge Distance 112022 Nails at V O.G. (typ.) t fastener, as dbed in Note 1 Hardie3offit, Cemsoffit i 20ga,3-5/6'� 1-5/8" (Metal C-stud i The wail and soffit frames are to be L— designed by the Architect or Engineer of Record In compliance with the Florida Building Code: SEE 9RO_DUC pi: GS—Q -TIO-N S D>` EE A HardieSofft & Cemsoffl* materials are nonasbestosfiber-cement products tested In accordance with ASTM 01186 1 Grade II, TypeA and meeting the . requirements of the Florida Building Code. 20ga.3-51B"X1-518" I0FFITD_ifUtE�1SI0 5. Nietai Gstud Width Length Th{clmess 4' 8' l: rM- eSoffU_it, j}ESICN PRESS_i lE RA JN_G Installation Design Pressure I. Metal Studs 55 f 414 • SECTION B_B lt�2c?1Cti7Ci ��� \6,t+t _ i'>:2WVCi' REVISER US `W'npiyias wtid On JEloride es oc� with tyre FbCri� Buildxtrg corbG =0=ft No 13�p3t I •G� i 12 Am00ftbe NMI, 1 e'vteafi .O17 '�r �D' S UEOF H Cpoacramos_��pR1DP 'o`,� +s�0 ttt�l BARA(_O_FFr[,._QElV[SQFEU-P_ANEL INSTAL I0kDETAiL_S Installation shall be done in conformance with this Notice of Accepi���� L N arttl Aand�!httufi{'ahufacturer s installation recommendations, and the applicable sections of the Florlda Building Code. n Metal studs where Hardie5ofit, Cemsoffit will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.Q.k x The soffit shall be installed over minimum 20ge, Nominal 3-5l6" X 1-5/8" Metal C-studs spared a maximum of 16" O.C. " [Note 11 The soffit fastener shall be a minimum No. 8-18, 0.3161 head diameter X 1-114" long* ribbed bugle head screw (*or screw shall have at least 3 full threads penetrating metal framing);the fasteners shalt be spaced at 6" O.C. at panel edges and intermediate studs; the fasteners shall be driven into metal studs located at 16" O.C. • Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of 2" from comers. Creator. E.•Gonzales SIZE scALE HARDIESOFFIT, CEMSOFFIT PANEL INSTALLATION DETAILS METALSTUD CONSTRUCTION James Hardie Building Products, )no. 10901 Elm Avenue Fontana, CA 92337 PNL-PLK-SOFF V2" LA V-0" I Date; 4/24/2013 1 SHEFT 11 OF 12 BAotn. is.001n, Cladding , Framing 6.0oln. PRODUCT RENEWED REVISED PRODr t as complying with the Florida Building Code ag winacd& Aped P S 1 Yi08WtbttFtori& �i C-& �!J p�alt/j�ii NOA-No. 'I7-0406.06 Expiration 05/01/2022MIA t A�bm*140 �3 7 mod° ��F+i j�}j�A I By iyljffitl prodoocContaol �� ' Miami-DZdf Product Control t� 2 • '��ss�o�P� FRAMING �'''--�,.�,,.:�►�' a NOMINAL 20 GAUGE; 3-5/6" X 1.6/8" STI=EL STUDS 16" O.G. FASTENED WITH 6/8" WAFER HEAD SCREWS (2 PER TOp FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE AND BOTTOM CONNECTION) NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) ■ THE WALLAND SOFFIT FRAMES ARE TO BE DESIGNED " BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE CJ ADDII41Z HARDIESOFFIT, CEMSOFFIT PANEL THE SOFFIT IS FASTENED WITH NO.8-18, 0.315" HEAD INSTALLATION pETAILS METAL STUD CONSTRUCTION DIAMEi•ERX 1-1/�4' LONG CORROSION RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE. AT LEAST 3 James Hardie Building Produots, Inc. FULL THREADS PENETRATING THE METAL FRAMING), PLACE SCREWS 5' O.C. AT PANEL EDGES AND INTERMEDIATE 10901. Elm Avenue STUDS ® Fontana, CA 92337' Phone: 909-355-6300 SIZ6 FSOM NO DWO NO RE Fax 909:427-063�4 A PNL-PLK-SOFF 9 Creator: E. Gonzales sms 1" = d'-0" Date: 4/24/2013 smiF 12 OV 12