Loading...
HomeMy WebLinkAboutmini split iinfojuv rvame: System Reference: Indoor Unit: SLZ-KF12NA INDOOR UNIT FEATURES • Ceiling -recessed cassette (24"x24") ductless heat pump • Install SLZ in a drywalled ceiling (with an access panel for servicing) or in a 2'x2' drop ceiling • Wide airflow pattern for excellent air distribution • Fresh air intake provided in the main body • Built-in drain condensate lift mechanism (lifts to 33") • Multiple control options available: - kumo cloud® smart device app for remote access - Third -party interface options - Wired or wireless controllers • Long -life air filter included • Individual vane control OUTDOOR UNIT FEATURES • Variable speed INVERTER -driven compressor • Innovative Joint Lap DC Motor leads to high efficiency and reliability • Pulse Amplitude Modulation technology • High-performance grooved piping for increased heat exchange efficiency Outdoor Unit: SUZ-KAl2NA2 Date: Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Maximum Capacity Btu/h 12,000 Rated Capacity Btu/h 12,000 Minimum Capacity Btu/h 3,900 Cooling at 95°F' Maximum Power Input W 900 Rated Power Input W 900 Moisture Removal Pints/h 2.8 Sensible Heat Factor 0.74 .7 Power Factor (208/230V) Maximum Capacity % Btu/h 98 13,200 Rated Capacity Btu/h 13,200 Cooling at 82°F Minimum Capacity Btu/h 4,400 Maximum Power Input W 810 — Rated Power Input Maximum Capacity W Btu/h 810 13,000 Rated Capacity Btu/h 13,000 Heating at 47°FZ Minimum Capacity Btu/h 4,800 Maximum Power Input W 1,310 Rated Power Input W 1,310 Power Factor Maximum Capacity % Btu/h 98 8,900 Heating at 17°F3 Rated Capacity Btu/h 8,900 Maximum Power Input W 1,130 Heating at 5°Fa Rated Power Input Maximum Capacity W Btu/h 1,130 6,100 Maximum Power Input W 760 Heating at -4°F5 Maximum Capacity Btu/h SEER 4,500 22.0 EERI 13.3 HSPF (IV) 11.4 Efficiency COP at 47°F2 2 91 COP at 17°F in Maximum Capac1ty3 2.31 COP at 5°F in Maximum Capacitya 2.35 ENERGY STAR® Certified (ENERGY STAR products are third -party certified by an EPA -recognized Certification Body.) Voltage, Phase, Frequency Yes 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187-253 Voltage: Indoor - Outdoor, S1-S2 V AC 208/230 Electrical Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote Controller V DC 12 Recommended Fuse/Breaker Size A 15 Recommended Wire Size (Indoor - Outdoor) AWG 14 Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. MCA A 0.30 Fan Motor Full Load Amperage A 0.24 Fan Motor Output W 50 Airflow Rate at Cooling, Dry CFM 335-265-230 Airflow Rate at Cooling, Wet CFM 302-252-207 Airflow Rate at Heating, Dry CFM 335-265-230 Sound Pressure Level (Cooling) dB(A) 34-30-25 Sound Pressure Level (Heating) dB(A) 34-30-25 Drain Pipe Size In. (mm) 1-1/4 (32) Indoor Unit Condensate Lift Mechanism, Maximum Distance In. (mm) 33 (850) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W: In. (mm) 22-7/16 (570) D: In. (mm) 22-7/16 (570) H: In. (mm) 9-21/32 (245) Package Dimensions W: In. (mm) 24-13/32 (620) D: In. (mm) 27-15/16 (710) H: In. (mm) 9-7/16 (240) Unit Weight Lbs. (kg) 31 (13.9) Package Weight — Lbs. (kg) 37 (17) Indoor Unit Operating Temperature Range Cooling Intake Air Temp (Maximum / Minimum)* °F 95F D.B ! 71 F W.B // 67F D.B / 57F W.B Heating Intake Air Temp (Maximum / Minimum) -F 80F D.B // 70F D.B MCA A 9 MOCP A 16 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 55 Airflow Rate CFM 1,229 / 1,172 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Blue Fin Coating on Heat Exchanger Yes Outdoor Unit Sound Pressure Level, Cooling' dB(A) 49 Sound Pressure Level, Heating2 dB(A) 51 Compressor Type DC INVERTER -driven Twin Rotary Compressor Model SNB092FQAMT Compressor Rated Load Amps A 6.6 Compressor Locked Rotor Amps A 8.2 Compressor Oil Type H Charge oz. FV50S H 11.8 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater --- Optional Unit Dimensions W: In. (mm) _— 31-1/2 (800) Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. _ D: In. (mm) 11-1/4 (285) H: In. (mm) 21-5/8 (550) Package Dimensions — _ W: In. (mm) 38 (940) D: In. (mm) 14-15/16 (380) H: In. (mm) 24-13/16 (630) Unit Weight Lbs. (kg) 81 (37) Package Weight Lbs. (kg) 88 (40) Cooling Air Temp (Maximum / Minimum)" °F 115 / 14 Outdoor Unit Operating Temperature Range Cooling Thermal Lock -out / Re -start Temperatures- °F -1 / 3 Heating Air Temp (Maximum / Minimum) `F 75/-4 Heating Thermal Lock -out / Re -start Temperatures" °F -9 / -4 Refrigerant Type R410A Charge Lbs, oz 2,9 Gas Pipe Size O.D. (Flared) In.(mm) 3/8 (9.52) Liquid Pipe Size O.D. (Flared) In.(mm) 1/4 (6.35) Piping Maximum Piping Length Ft. (m) 65 Maximum Height Difference Ft. (m) 40 Maximum Number of Bends 10 Notes AHRI Rated Conditions Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is 2Heatin determined at a fixed g at 47°F (Indoor 1/ Outdoor) °F 70 DB, 60 WB H 47 DB, 43 WB compressor speed) 3Heating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB H 17 DB, 15 WB Conditions 41-leating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB H 4 DB, -5 WB 5Heating at -4°F (Indoor H Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB "Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. "'System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Wireless Signal Receiver ❑ PAR-FA32MA-W Wireless Signal Receiver ❑ PAR-FA32MA-E Wireless Remote Receiver Panel ❑ PAR-SF9FA-E Wireless Remote Controller ❑ PAR-SL100A-E Backlit, Wall -mounted, Wireless Controller ❑ MHK1 Portable Central Controller ❑ MCCH1 Wired MA Controller ❑ PAR-33MAA Simple MA Controller ❑ PAC-YT53CRAU Touch MA Controller ❑ PAR-CT01 MAU-SB Wired Remote Sensor ❑ PAC-SE41TS-E Wireless Temperature and Humidity Sensor PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 ❑ MO Flush Mount Remote Temperature Sensor ❑ PAC-USSEN001-FM-1 System Control Interface ❑ MAC-3331F-E Wireless Interface ❑ PAC-USWHS002-WF-1 Thermostat Interface ❑ PAC-US444CN-1 kumo station® ❑ PAC-WHS01 HC-E USNAP Interface ❑ PAC-WHS01 UP-E IT Extender ❑ PAC-WHS011E-E BACnet® and MODBUSO Interface ❑ PAC-UKPRC001-CN-1 External Fan / Heater Control Relay Adapter ❑ CN24RELAY KIT-CM3 Wire for Remote on/off with CN32 connector ❑ PAC-715AD Connector and wire for Operation status/error using CN51 ❑ PAC-725AD Connector cable for remote display ❑ PAC-SA88HA-EP Connector for CN32 (remote on/off) ❑ PAC-SE55RA-E Remote Operation Adapters ❑ PAC-SF40RM-E Grille (required) ❑ SLP-18FAU 3D i-see SensorTM Corner Panel ❑ PAC-SF1ME-E Grille with 3D i-see SensorTM ❑ SLP-18FAEU Blue Diamond Sensor Extension Cable —15 Ft. ❑ C13-103 Blue Diamond Alarm Extension Cable —6.5 Ft. ❑ C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps ❑ C21-014 Blue Diamond Rubber Foot Pads ❑ F10-010 Mini Condensate Pump-230 volt application ❑ S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor ❑ X87-835 - 110 to 250V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] ❑ X87-721 - 208/230V Drain Pan Level Sensor ❑ DPLS2 (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White ❑ � Unable to use with wira�asc ramn4c ��.,rr�uo.. TAZ-MS303W Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. FOR REMOTE CONTROLLER 1 TERMINAL BLOCK TERMINAL BLOCK AR INT, GRILLE -SEE SENSOR CORNER PANEL / - ) AIR OUTLET HOLE U 0 STANDARD ATTACHMENT PO��*ION STANDARD IN THE CASE OF STANDARD PANEL `6100\ b. N oe 9 -]/ (07 .d) T T H LE FRESH AIR INTAKE Em RECEIVER CORNER PANEL STANDARD ATTACHMENT —THING N THE CASE OF STANDARD PANEL DRAIN HOL DETAILS OF RECEIVING �I�( RECEIVER By OEFR0.5T/STA�L�J By LAMP EMERGENCY OPERATION EMERGENCY OPERATION SWITCHIHEATING) SWITCH(COOLING) Unit: inch (mm) MODELS m P FRIGERENT PIPE 0 REFRIGERENT PIPE GAS) A B SLZ-KF09/12NA.TH FV6116.33mm1 FLARED CONNECTION 1/41 13/8119.52mm) FLARED CONNECTION 3/BF (63mm1 2-15/3 p2mM 2-P/3 SLZ-KF15/IBNA.TH 1114116. CmZ FLARED CONNECTKN 1/4F 1/21012.Jmm) FLARED CONNECTION 1/2P (63mm1 2-15/32 IJBmmI 3-1/16 Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: inch(mm) REQUIRED SPACE *1 4 in. (100 mm) or more when front and sides of the unit are clear U o 4i �(7pp 0..\r.o� Ce mar �ih� 15-3/4 j v Air in Drain hole 01-21/32 (KA09i12115NA) " Drain hole 01-5/16 (KA09i12i15NAH) v Air in Oomml v 7q/n o r i ° � 0. �2 °<e 2 o� (asp °C �011e0��i } o a rn O � N co C '2 When any 2 sides of left, right and rear of the unit are clear Air out 2- holes 3/8x13/16 1 FORM# SLZ-KF12NA / SUZ-KAl2NA2 - 201901 Liquid refrigerant pipe joint Refrigerant pipe (flared) e 1/4 Gas refrigerant pipe joint Refrigerant pipe (flared) o 3/8 (KA09/12) _ s 1/2 (KA15) atMITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.rnehvac.com c ET4 . Intertek Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Jop Name: System Reference: Date: Indoor Unit: Outdoor Unit: SVZ-KP12NA SUZ-KAl2NA2 A �d��iilllllllllilllilillllllll� a,y �� ��.. Illlilllllllllllllllllllllilllll �x ��Alllli�llllllllllllililll��llllsz$�} . �r ���IIIIIIIIIIIII�i INDOOR UNIT FEATURES • Ducted air handler provides a solution to cool and heat larger zones • Highly efficient completely enclosed EC motor • Selectable external static pressure: 0.30, 0.50 and 0.80 in.WG with 3 fan speeds at each static setting • 1 inch R4.2 fiberglass free insulation reduces condensation and increases efficiency • Positive pressure cabinet with air leakage of less than 2.0% at 1.0 in. w.g. (Tested per ASHRAE Standard 193) • Unique blow through design allows simple coil cleaning when the blower is removed • Multi -position installation: horizontal (left or right), vertical (upflow) • Optional electric heat kit for additional heating capacity • Optional humidifier control, ERV control and auxiliary heat control • Optional downflow kit OUTDOOR UNIT FEATURES • Variable speed INVERTER -driven compressor • Innovative Joint Lap DC Motor leads to high efficiency and reliability • Pulse Amplitude Modulation technology • High-performance grooved piping for increased heat exchange efficiency Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Maximum Capacity Btu/h 12,000 Rated Capacity Btulh 12,000 Minimum Capacity Btu/h 4,300 Cooling at 95°F1 Maximum Power Input W 940 Rated Power Input W 940 Moisture Removal Pints/h 1.2 Sensible Heat Factor 0.89 Power Factor (208/230V) % 95 Maximum Capacity Btu/h 13,100 Rated Capacity Btu/h 13,100 Cooling at 82°F Minimum Capacity Btu/h 4,800 Maximum Power Input W 860 Rated Power Input W 860 Maximum Capacity Btu/h 16,700 Rated Capacity Btu/h 15,000 Heating at 47°FZ Minimum Capacity Btu/h 4,700 Maximum Power Input W 1,440 Rated Power input W 1,210 Power Factor % 97 Maximum Capacity Btu/h 9,900 Heating at 17°F 3 Rated Capacity Btu/h 9,900 Maximum Power Input W 1,120 Rated Power Input W 1,120 Heating at 5°Fa Maximum Capacity Btu/h 7,800 Maximum Power Input W 830 Heating at -4°F5 Maximum Capacity Btu/h 5,800 SEER 18.0 EERI 12.7 HSPF (IV) 12.1 Efficiency COP at 47°F2 3.63 COP at 17°F in Maximum Capacity3 2.59 COP at 5°F in Maximum Capacitya 2.75 ENERGY STAR® Certified (ENERGY STAR products are third -party certified by an EPA -recognized Certification Body.) Yes Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187-253 Voltage: Indoor -Outdoor, S1-S2 V AC 208/230 Electrical Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote Controller V DC 12 Recommended Fuse/Breaker Size A 15 Recommended Wire Size (Indoor - Outdoor) AWG 14 Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. MCA A 3 Fan Motor Full Load Amperage A 2.4 Fan Motor Output W 121 Airflow Rate at Cooling, Dry CFM 448-381-278 Airflow Rate at Heating, Dry CFM 448-381-278 Sound Pressure Level (Cooling) dB(A) 39-36-29 Sound Pressure Level (Heating) dB(A) 39-36-29 External Static Pressure in.WG 0.30-0.50-0.80 Drain Pipe Size In. (mm) 3/4 (19) Indoor Unit Heat Exchanger Type Plate fin coil External Finish Color Black Unit Dimensions W: In. (mm) 17 (432) D: In. (mm) 21-5/8 (549) H: In. (mm) 39-13/16 (1,011) Package Dimensions W: In. (mm) 18 (460) D: In. (mm) 28-3/4 (730) H: In. (mm) 44-3/8 (1,130) Unit Weight Lbs. (kg) 93 (42) Package Weight Lbs. (kg) 106 (48) Indoor Unit Operating Temperature Cooling Intake Air Temp (Maximum / Minimum)" °F 90F D.B / 71 F W.B H 67F D.B / 57F W.B Range Heating Intake Air Temp (Maximum / Minimum) of 80F D.B // 70F D.B MCA A 9 MOCP A 16 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 55 Airflow Rate CFM 1,229 / 1,172 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Blue Fin Coating on Heat Exchanger Yes Outdoor Unit Sound Pressure Level, Cooling' dB(A) 49 Sound Pressure Level, Heatingz dB(A) 51 Compressor Type DC INVERTER -driven Twin Rotary Compressor Model SNB092FQAMT Compressor Rated Load Amps A 6.6 Compressor Locked Rotor Amps A 8.2 Compressor Oil Type H Charge oz. FV50S H 11.8 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater Optional Unit Dimensions W: In. (mm) 31-1/2 (800) D: In. (mm) 11-1/4 (285) Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. H: In. (mm) 21-5/8 (550) Package Dimensions W: In. (mm) 38 (940) D: In. (mm) 14-15/16 (380) H: In. (mm) 24-13/16 (630) Unit Weight Lbs. (kg) 81 (37) Package Weight Lbs. (kg) 88 (40) Cooling Air Temp (Maximum / Minimum)* °F 115 / 14 Outdoor Unit Operating Cooling Thermal Lock -out / Re -start Temperatures" °F -1 / 3 Temperature Range Heating Air Temp (Maximum / Minimum) °F 75 / -4 Heating Thermal Lock -out / Re -start Temperatures** °F -g / -4 Refrigerant Type R410A Charge Lbs, oz 2,9 Gas Pipe Size O.D. (Flared) In.(mm) 3/8 (9.52) Liquid Pipe Size O.D. (Flared) In.(mm) 1/4 (6.35) Piping Maximum Piping Length Ft. (m) 65 Maximum Height Difference Ft. (m) 40 Maximum Number of Bends 10 Notes AHRI Rated Conditions I Cooling (Indoor // Outdoor) °F 80 DB, 67 WB !/ 95 DB, 75 WB (Rated data is determined at a fixed 2Heatin at 47°F Indoor // Outdoor g ( ) °F 70 DB, 60 WB // 47 DB, 43 WB compressor speed) 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB !/ 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB SHeating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Wireless Signal Receiver ❑ PAR-FA32MA-W Wireless Signal Receiver ❑ PAR-FA32MA-E Wireless Remote Controller ❑ PAR-FL32MA-E Backlit, Wall -mounted, Wireless Controller ❑ MHK1 Portable Central Controller ❑ MCCH1 Wired MA Controller ❑ PAR-33MAA Simple MA Controller ❑ PAC-YT53CRAU Touch MA Controller ❑ PAR-CT01 MAU-SB PAR -CT 1 MAU- B Airzone ZBS Wired Blueface Principal Controller White ❑ ECB Airzone ZBS Wired Think Controller White ❑ AZZBSTHINKCB Airzone ZBS Wireless Think Controller White ❑ AZZBSTHINKRB Airzone ZBS Wired Lite Controller White ❑ AZZBSLITECB Airzone ZBS Wireless Lite Controller White ❑ AZZBSLITERB Wired Remote Sensor ❑ PAC-SE41TS-E Wireless Temperature and Humidity Sensor ❑ PAC-USWHS003-TH-1 El Outside Air Sensor for MHK1 ❑ MOS1 Flush Mount Remote Temperature Sensor ❑ PAC-USSEN001-FM-1 Wireless Interface ❑ PAC-USWHS002-WF-1 Thermostat Interface ❑ PAC-US444CN-1 kumo station® ❑ PAC-WHS01 HC-E USNAP Interface ❑ PAC-WHS01 UP-E IT Extender ❑ PAC-WHS011E-E BACnet® and MODBUS® Interface ❑ PAC-UKPRC001-CN-1 External Fan / Heater Control Relay Adapter ❑ CN24RELAY-KIT-CM3 Connector cable for remote display ❑ PAC-SA88HA-EP Connector for CN32 (remote on/off) ❑ PAC-SE55RA-E Remote Operation Adapters ❑ PAC-SF40RM-E MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor ❑ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 Btu/h [recommended] ❑ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] ❑ X87-721 - 208/230V Drain Pan Level Sensor ❑ DPLS2 (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 (30A/600WUL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W Separate Power Terminal Block Kit ❑ SPTB1 Electric Heat Lockout Control ❑ ETC-211000-000 Downflow Kit ❑ DFK-S 3kW Electric Heater ❑ EH03-SVZ-S _ 5kW Electric Heater Unable to use with wireless remote contmilar ❑ EH05-SVZ-S Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide ❑ MAC-881 SG Optional Defrost Heater ❑ MAC-640BH-U Hail Guard ❑ HG-B4 Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ DSD-DSD-44 0P 00P Condensing Unit Mounting Pad 16" x 36" x 3" ❑ ULT Outdoor Unit Stand —12" High ❑ QSMS1201 M Outdoor Unit Stand —18" High ❑ QSMS1801M Outdoor Unit Stand —24" High ❑ QSMS2401M Heavy Duty Wall Mounting Bracket —Coated Steel ❑ QSWB2000M-1 Heavy Duty Wall Mounting Bracket —316 Series Stainless Steel ❑ QSWBSS 15' x 1/4" x 15' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-15 30' x 1/4" x 30' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-30 50' x 1/4" x 50' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-50 65' x 1/4" x 65' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-65 Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. o26 Knockout Hole (Indoor / Outdoor unit connectlon) (Remote controller transmission) Lef(side view Unit:mm0n.) Top Unit:mm(in.) view Note: Electrical entrance for SVZ located on both left and right side of the cabinet. o26 Knockout Hole See right or Left side view for knockout 026 Knockout Hole locations. for electrical heat wiring 2-o4.6 Burring Holes for electric heat installation Ee e19 cy drain ng) 19.05(3/4) 3/4"FPT. Secondary drain pipe (Emergency draining) e19.05(3/4) 3/4"FPT_ Model Nominal Filter Size Duct Connection SVZ-KP12NA 508 x 406.4 x 25.4 (20 x 16 x 1) 376 x 402 (14-13/16 x 15-7/8) SVZ-KP18NA SVZ-KP24NA SVZ-KP30NA 508 x 508 x 25.4 (20 x 20 x 1) 1 477 x 402 (18-13/16 x 15-7/8) SVZ-KP36NA Bottom view tQ�1[fl (Horizontal Right) o26 Knoi (Indoor / C �l connectic Primary drain pipe (Rem nnectitl oG9AV3/4)13j4"FPT �n Control box '(Remove Blower Panel) Ottom Model SVZ-KP12NA A 432 (17) B 376 (14-13/16) C 281 (11-1/8) D 224 (8-7/8) E 1,010.8 (39-13/16) F 680 (26-13/16) G 823 (32-7/16) H 735.5 (29) J 360 (14-3/16) Gas Pipe 0 9.52 (3/8) Liquid pipe o 6.35 (1/4) SVZ-KP18NA o 12.7 (1/2) SVZ-KP24NA 015.88 (5/8) o 9.52 (3/8) SVZ-KP30NA 534 t (21) 477 (18-13/16) 382.6 (15-1/8) 266.5 (10-1/2) 1,113.8 (43-7/8) 737 (29-1/16) 953.5 (37-9/16 792 (31-3/16) 461 (18-3/16) SVZ-KP36NA Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: inch(mm) REQUIRED SPACE "1 4 in. (100 mm) or more when front and sides of the unit are clear IDID � U 1�� ell a v Air in Drain hole 41-21/32 (KA09/12115NA) n Drain hole 01-5/16 (KA09/12/15NAH) Air in 2 o m 9J \r p<0 � � N 1-9/16 o Air our 2-holes 3/8X13/16 FORM# SVZ-KP12NA / SUZ-KAl2NA2 - 201901 0a. �� '2 When any 2 sides of left, right and rear of the unit are clear Liquid refrigerant pipe joint Refrigerant pipe (flared) o 1/4 Gas refrigerant pipe joint Refrigerant pipe (flared) o 3/8 (KA09/12) o 1/2 (KA15) MtMITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com %. Intertek Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.