Loading...
HomeMy WebLinkAbout5184 TURNPIKE FEEDER RD SPECS16.0 Rheem Classic® Series Air Conditioners FORM NO. A11-220 REV. 9 •Composite base pan – dampens sound, captures louver panels, eliminates corrosion and reduces number of fasteners needed •Powder coat paint system – for a long lasting professional finish •Scroll compressor – uses 70% fewer moving parts for higher efficiency and increased reliability •Modern cabinet aesthetics – increased curb appeal with visu- ally appealing design •Curved louver panels – provide ultimate coil protection, enhance cabinet strength, and increased cabinet rigidity •Optimized fan orifice – optimizes airflow and reduces unit sound •Rust resistant screws – confirmed through 1500-hour salt spray testing •PlusOne™ Expanded Valve Space – 3"-4"-5" service valve space – provides a minimum working area of 27-square inches for easier access •PlusOne™ Triple Service Access – 15" wide, industry lead- ing corner service access – makes repairs easier and faster. The two fastener removable corner allows optimal access to internal unit components. Individual louver panels come out once fastener is removed, for faster coil cleaning and easier cabinet reassembly •Diagnostic service window with two-fastener opening – provides access to the high and low pressure. •External gauge port access – allows easy connection of “low-loss” gauge ports •Single-row condenser coil – makes unit lighter and allows thorough coil cleaning to maintain “out of the box” performance •35% fewer cabinet fasteners and fastener-free base – allow for faster access to internal components and hassle-free panel removal •Service trays – hold fasteners or caps during service calls •QR code – provides technical information on demand for faster service calls •Fan motor harness with extra long wires allows unit top to be removed without disconnecting fan wire. Air Air Conditioners RA14 Series “Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystar.gov.” RA14 Series Efficiencies up to 14 SEER /11.5 EER Nominal Sizes 11/2 to 5 Ton [5.28 to 17.6 kW] Cooling Capacities 17.3 to 60.5 kBTU [5.7 to 17.7 kW] Air Table of Contents RA14 Series 2 TABLE OF CONTENTS Standard Feature ......................................................................................................3 Available SKUs ........................................................................................................3 Features & Benefits ..............................................................................................4-5 Model Number Identification ................................................................................6-7 General Data/Electrical Data ....................................................................................8 Accessories ............................................................................................................9 Weighted Sound Power ............................................................................................9 Unit Dimensions......................................................................................................10 Clearances ..............................................................................................................11 Wiring Diagrams ....................................................................................................12 Application Guidelines ............................................................................................12 Refrigerant Line Size Information ......................................................................13-16 Performance Data ..................................................................................................17 Guide Specifications ..............................................................................................18 Limited Warranty ....................................................................................................19 Air Standard Feature/Available SKUs RA14 Series 3 STANDARD FEATURES Feature 18 24 30 36 42 48 60 R-410a Refrigerant √√√√√√√ Maximum SEER 15.5 15 15.5 15.5 15 15 14 Maximum EER 13 13 13 13 13 13 12 Scroll Compressor √√√√√√√ Field Installed Filter Drier √√√√√√√ Front Seating Service Valves √√√√√√√ Internal Pressure Relief Valve √√√√√√√ Internal Thermal Overload √√√√√√√ Long Line capability √√√√√√√ Low Ambient capability with Kit √√√√√√√ 3-4-5 Expanded Valve Space √√√√√√√ Composite Basepan √√√√√√√ 2 Screw Control Box Access √√√√√√√ 15" Access to Internal Components √√√√√√√ Quick release louver panel design √√√√√√√ No fasteners to remove along bottom √√√√√√√ Optimized Venturi Airflow √√√√√√√ Single row condenser coil √√√√√√√ Powder coated paint √√√√√√√ Rust resistant screws √√√√√√√ QR code √√√√√√√ External gauge ports √√√√√√√ Service trays √√√√√√√ √ = Standard Standard Feature Table Available Models Description RA1418AJ1NA Classic ® Series 1 1/2 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60 RA1418AJ1NB Classic ® Series 1 1/2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 RA1424BJ1NA Classic ® Series 2 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60 RA1424BJ1NB Classic ® Series 2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 RA1430AJ1NA Classic ® Series 2 1/2 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60 RA1430AJ1NB Classic ® Series 2 1/2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 RA1436AC1NB Classic ® Series 3 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 RA1436AD1NB Classic ® Series 3 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-460/3/60 RA1436AJ1NA Classic ® Series 3 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60 RA1436AJ1NB Classic ® Series 3 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 RA1442AD1NB Classic ® Series 3 1/2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-460/3/60 RA1442CC1NB Classic ® Series 3 1/2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 RA1442CJ1NA Classic ® Series 3 1/2 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60 RA1442CJ1NB Classic ® Series 3 1/2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 RA1448AC1NB Classic ® Series 4 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 RA1448AD1NB Classic ® Series 4 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-460/3/60 RA1448AJ1NA Classic ® Series 4 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60 RA1448AJ1NB Classic ® Series 4 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 RA1460AD1NB Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-460/3/60 RA1460BC1NB Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 RA1460BJ1NA Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60 RA1460BJ1NB Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 RA1460CC1NB Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 RA1460CD1NB Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-460/3/60 RA1460CJ1NA Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60 RA1460CJ1NB Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 Available SKUs The RA14 is our 14 SEER air conditioner and is part of the Rheem air conditioner product line that extends from 13 to 20 SEER. This highly featured and reliable air conditioner is designed for years of reliable, efficient operation when matched with Rheem indoor aluminum evaporator coils and furnaces or air handler units with aluminum evaporators. Our unique composite base () reduces sound emission, elimi- nates rattles, significantly reduces fasteners, eliminates corro- sion and has integrated brass compressor attachment inserts (). Furthermore it has incorporated into the design, water management features, means for hand placement () for unit maneuvering, screw trays () and inserts for lifting off unit pad. () Service Valves () are rigidly mounted in the composite base with 3" between suction and discharge valves, 4" clearance below service valves and a minimum of 5" above the service valves, creating industry leading installation ease. The minimum 27 square-inches around the service valves allows ample room to remove service valve schrader prior to brazing, plenty of clear- ance for easy brazing of the suction and discharge lines to ser- vice valve outlets, easy access and hookup of low loss refriger- ant gauges (), and access to the service valve caps for opening. For applications with long-line lengths up to 250 feet total equivalent length, up to 200 feet condenser above evapora- tor, or up to 80 feet evaporator above condenser, the long-line instructions in the installation manual should be followed. Controls are accessed from the corner of the unit by removing only two fasteners from the control access cover, revealing the industry’s largest 15" wide and 14" tall control area (). With all this room in the control area the high voltage electrical whip () can easily be inserted through the right size opening in the bot- tom of the control area. Routing it leads directly to contractor lugs for connection. The low voltage control wires () are easily connected to units low voltage wiring. If contactor or capacitor () needs to be replaced there is more than adequate space to make the repair. Furthermore, if high pressure and low pressure model was not purchased but is desired to be installed in the field, the service window () can be removed by removing two screws, to access the high and low side schrader fittings for easy field installation. The entire corner can be removed providing ultimate access to install the high and low pressure switch. () If in the rare event, greater access is needed to internal compo- nents, such as the compressor, the entire corner of the unit can be removed along with the top cover assembly to have unprece- dented access to interior of the unit (). Extra wire length is incorporated into each outdoor fan and compressor so top cover and control panel can be positioned next to the unit. With minimal effort the plug can be removed from the compressor and the outdoor fan wires can be removed from the capacitor to allow even more uncluttered access to the interior of the unit (). Outdoor coil heights range from as short as 22" to 32", aiding access to the compressor. Disassembly to this degree and com- plete reassembly only takes a first time service technician less than 10 minutes. () All units utilize strong formed louver panels which provide indus- try leading coil protection. Louver removal for coil cleaning is accomplished by removing one screw and lifting the panel out of the composite base pan. () All RA14 units utilize single row coils () making cleaning easy and complete, restoring the performance of the air conditioner back to out of the box perfor- mance levels year after year. The outdoor fan motor has sleeve bearings and is inherently protected. The motor is totally enclosed for maximum protection from weather, dust and corrosion. Access to the outdoor fan is made by removing four fasteners from the fan grille. The outdoor fan can be removed from the fan grille by removing 4 fasteners in the rare case outdoor fan motor fails. Each cabinet has optimized composite () fan orifice assuring efficient and quiet airflow. 1 2 3 4 7 8 9 10 12 13 6 11 5 14 15 15 17 16 19 Air Features & Benefits RA14 Series 4 Introduction to RA14 Air Conditioner 1 4 64 3 5 2 8 11 910 13 12 19 7 17 16 14 18 15 Air Features & Benefits RA14 Series 5 The entire cabinet has powder post paint () achieving 1000 hour salt spray rating, allowing the cabinet to retain its aesthetics throughout its life. Scroll compressors with standard internal pressure relief and internal thermal overload are used on all capacities assuring longevity of high efficient and quiet operation for the life of the product. Each unit is shipped with filter drier for field installation and will trap any moisture or dirt that could contaminate the refrigerant system. All cabinets have industry leading structural strength due to the composite base pan (), interlocking corner post (), formed curved louver panels () and drawn top cover () making it the most durable cabinet on the market today. Each RA14 capacity has undergone rigorous psychometric test- ing to assure performance ratings of capacity, SEER and EER per AHRI Standard 210/240 rating conditions. Also each unit bears the UL mark and each unit is certified to UL 1995 safety standards. Each unit has undergone specific strain and modal testing to assure tubing () is outside the units natural frequency and that the suction and discharge lines connected to the compressor withstand any starting, steady state operation or shut down forces imposed by the compressor. All units have been sound tested in sound chamber to AHRI 270 rating conditions, and A-weighted Sound Power Level tables produced, assuring units have acceptable noise qualities (see page 9). Each unit has been ran in cooling operation at 95°F and 82°F and sound ratings for the RA14 range from as low as 74 dBA to 77 dBA. All units have been ship tested to assure units meet stringent “over the road” shipping conditions. As manufactured all units in the RA14 family have cooling capa- bility to 55 °F. Addition of low ambient control will allow the unit to operate down to 0°F. Factory testing is performed on each unit. All component parts meet well defined specification and continually go through receiving inspections. Each component installed on a unit is scanned, assuring correct component uti- lization for a given unit capacity and voltage. All condenser coils are leak tested with pressurization test to 550#’s and once installed and assembled, each units’ complete refrigerant system is helium leak tested. All units are fully charged from the factory for up to 15 feet of piping. All units are factory run tested. The RA14 has a 10-year conditional compressor and parts war- ranty (registration required). Optional Accessories (Refer to accessory chart for model #) Compressor Crankcase Heater Protects against refrigerant migration that can occur during low ambient operation Compressor Sound Cover • Reinforced vinyl compressor cover containing a 1½ inch thick batt of fiberglass insulation • Open edges are sealed with a one-inch wide hook and loop fastening tape Compressor Hard Start Kit • Single-phase units are equipped with a PSC compressor motor, this type of motor normally does not need a potential relay and start capacitor • Kit may be required to increase the compressor starting torque, in conditions such as low voltage Low Ambient Kit • Air conditioners operate satisfactorily in the cooling mode down to 55°F outdoor air temperature without any additional controls • This Kit can be added in the field enabling unit to operate properly down to 0° in the cooling mode • Crankcase heater and freezestat should be installed on com- pressors equipped with a low ambient kit 3"/6"/12" • Gray high density polyethylene feet are available to raise unit off of mounting surface away from moisture Low Pressure • Can be added in field enabling the unit to shut off compressor on loss of charge NOTE: Unit can be purchased with high and low pressure installed at factory. (Refer to SKU list) High Pressure • Can be added in field enabling unit to shut off compressor if unit loses outdoor fan operation. NOTE: Unit can be purchased with high and low pressure installed at factory. (Refer to SKU list) Decorative Top • Can be installed on fan grille 25 20 2221 2423 20 24 23 22 21 25 RA1424AJ1NA*BrandProduct CategorySEERCapacity BTU/HRMajor Series*VoltageTypeControlsMinor Series**Option CodeRheem A - Air Conditioners 14 - 14 SEER18 - 18,000 [5.28 kW] 24 - 24,000 [7.03 kW] 30 - 30,000 [8.79 kW] 36 - 36,000 [10.55 kW] 42 - 42,000 [12.31 kW] 48 - 48,000 [14.07 kW] 60 - 60,000 [17.58 kW] A - 1st Design B - 2nd DesignJ - 1ph, 208-230/60 C - 3ph, 208-230/60 D - 3ph, 460/60 1 - Single-stageN - Non-CommunicatingA - 1st Design B - 2nd DesignN/ARP1424AJ1NA*BrandProductCategorySEERCapacityBTU/HRMajor Series*VoltageTypeControlsMinor Series**Option CodeRheem P - Heat Pump 13 - 13 SEER14 - 14 SEER16 - 16 SEER17 - 17 SEER20 - 20 SEER18 - 18,000 [5.28 kW]24 - 24,000 [7.03 kW]30 - 30,000 [8.79 kW]36 - 36,000 [10.55 kW]42 - 42,000 [12.31 kW]48 - 48,000 [14.07 kW]60 - 60,000 [17.58 kW]A - 1st DesignJ - 1ph, 208-230/60C - 3ph, 208-230/60D - 3ph, 460/601 - Single-stage2 - Two-stageV - InverterP - PistonC - CommunicatingN - Non-CommunicatingA - 1st DesignN/ARCF2417STAMCA*BrandProductCategoryTypeCapacityBTU/HRWidthEfficiencyMeteringDeviceMajorSeries*OrientationCasingMinor Series**OptionCodeRheem C - Evap CoilF - Furn CoilH - Air-HandlerCoil24 - 24,000 [7.03 kW]36 - 36,000 [10.55 kW]48 - 48,000 [14.07 kW]60 - 60,000 [17.58 kW]14 - 14"17 - 17.5"21 - 21"24 - 24.5"S- Standard Eff.M- Mid Eff.H- High Eff.T-TXVE-EEVP-PistonA - 1st DesignM - MultipoiseV - Vertical only/convertibleH - Ded.Horizontal onlyC - CasedU - UncasedA - 1st DesignN/A Air Model Number Identification RA14 Series 6 Heat Pumps (For Reference)** Furnace Coils (For Reference)** Air Conditioners**See page 3 for available SKU’s.**Model number ID’s are for reference only. Available SKU’s are listed on the standard features/available SKU page of model spec sheets. [ ] Designates Metric Conversions R96VA702317MSABrandSeriesMotorMajor RevInputBTU/HRStagesAir FlowCabinetWidthConfigurationNoxMinor RevRheem 90 - 90 AFUE92 - 92 AFUE95 - 95 AFUE96 - 96 AFUE97 - 97 AFUEV - Variable speedT - ConstantTorque(X-13)P - PSCA - 1st Design040 - 42,000 [12.31 kW]060 - 56,000 [16.41 kW]070 - 70,000 [20.51 kW]085 - 84,000 [24.62 kW]100 - 98,000 [28.72 kW]115 - 112,000 [32.82 kW]1 -Single-stage2 -Two-stageM - Modulating3 - up to 3 ton5 - 3 1/2 up to 5 ton14 - 14"17 - 17.5"21 - 21"24 - 24.5"M - MultiX - Low NoxS - StandardA - 1st Design Air Model Number Identification RA14 Series 7R802VA075317MSABrandSeriesStagesMotorMajor RevInputBTU/HRAir FlowCabinetWidthConfigurationNoxMinor RevRheem 80 - 80+ AFUE1 - Single-stage2 - Two-stageV - Variable speedT - Constant Torque (X-13)P - PSC premiumS - PSC standardA - 1st Design050 - 50,000 [15 kW]075 - 75,000 [22 kW]100 - 100,000 [29 kW]125 - 125,000 [37 kW]150 - 150,000 [44 kW]3 - up to 3 ton4 - 2 1/2 to 4 ton5 - 3 1/2 up to 5 ton14 - 14"17 - 17.5"21 - 21"24 - 24.5"M- MultiD- DownZ - Down &zero clearancedown flowX - Low NoxS - StandardA - 1st DesignRH1T3617STANAA000*BrandProductCategoryStages ofAirflowMotor TypeCapacityBTU/HRWidthCoil SizeMetering DeviceMajorSeries*ControlsVoltageMinorSeries**Factory HeatCapOptionCodeRheem H - AirHandler1 - Single-Stage2 - Two-StageM - ModulatingV - VariableSpeedT - ConstantTorqueP - PSC 24 - 24,000 [7.03 kW]36 - 36,000 [10.55 kW]48 - 48,000 [14.07 kW]60 - 60,000 [17.58 kW]14 - 14"17 - 17.5"21 - 21"24 - 24.5"S - StandardEff.M -Mid Eff.H - High Eff.T - TEVE - EEVP - PistonA - 1st DesignC -CommunicatingN -Non-commA - 1ph, 115/60J - 1ph, 208-240/60D - 3ph, 480/60A - 1st Design00 - nofactory heatwith optioncode*TBD 90%+ AFUE Gas Furnaces (For Reference)** 80% AFUE Gas Furnaces (For Reference)** Air Handlers (For Reference)****Model number ID’s are for reference only. Available SKU’s are listed on the standard features/available SKU page of model spec sheets. [ ] Designates Metric Conversions Air General Data/Electrical Data RA14 Series 8 Physical Data PHYSICAL DATA Model No.RA1418 RA1424 RA1430 RA1436 RA1442 RA1448 RA1460 Nominal Tonnage 1.5 2.0 2.5 3.0 3.5 4.0 5.0 Valve Connections Liquid Line O.D. – in.3/8 3/8 3/8 3/8 3/8 3/8 3/8 Suction Line O.D. – in.3/4 3/4 3/4 3/4 7/8 7/8 7/8 Refrigerant (R410A) furnished oz.¹68 80 87 106 134 129 201 Compressor Type Scroll Outdoor Coil Net face area – Outer Coil 9.1 11.1 12.1 14.8 17.3 18.9 32.3 Net face area – Inner Coil ——————— Tube diameter – in.3/8 3/8 3/8 3/8 3/8 3/8 3/8 Number of rows 1 1 1 1 1 1 1 Fins per inch 22 22 22 22 22 22 22 Outdoor Fan Diameter – in. 20 20 20 24 24 26 26 Number of blades 2 2 2 3 3 2 3 Motor hp 1/10 1/8 1/8 1/6 1/5 1/5 1/3 CFM 2225 2295 2605 3105 4105 4264 4775 RPM 1075 1121 1075 850 833 820 795 watts 130 138 142 173 236 236 239 Shipping weight – lbs. 143 148 158 178 207 232 247 Operating weight – lbs.122 141 151 171 200 221 240 Electrical Data Line Voltage Data (Volts-Phase-Hz)208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Maximum overcurrent protection (amps)²20 25 25 30 35 45 50 Minimum circuit ampacity³13 15 17 19 23 27 34 Compressor Rated load amps 9.7 10.9 12.8 14.1 16.7 19.9 23.7 Locked rotor amps 48 62.9 64 77 109 109 152.5 Condenser Fan Motor Full load amps 0.6 0.8 0.8 0.8 1.2 1.2 3.5 Locked rotor amps 1.1 1.5 1.4 1.5 2.0 2.3 - Line Voltage Data (Volts-Phase-Hz)———208/230-3-60 208/230-3-61 208/230-3-62 208/230-3-63 Maximum overcurrent protection (amps)²———20 25 30 35 Minimum circuit ampacity³———13 16 18 24 Compressor Rated load amps ———9 11.2 13.1 15.9 Locked rotor amps ———71 84 83.1 110 Condenser Fan Motor Full load amps ———0.8 1.2 1.2 3.5 Locked rotor amps ———1.5 3.0 2.3 - Line Voltage Data (Volts-Phase-Hz)———480-3-60 480-3-60 RA1442AD 480-3-60 480-3-60 RA1460AD Maximum overcurrent protection (amps)²———15 —15 15 ³Minimum circuit ampacity ———8 —9 10 Compressor Rated load amps ———5.6 —6.1 7.1 Locked rotor amps ———38 —41 52 Condenser Fan Motor Full load amps ———0.5 —0.6 0.5 Locked rotor amps ———1.1 —1.6 1.4 ¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required. ²HACR type circuit breaker of fuse. ³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements. Air Accessories/Weighted Sound Power RA14 Series 9 Accessories Model No.RA1418 RA1424 RA1430 RA1436 RA1442 RA1448 RA1460 Compressor crankcase heater*44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 44-17402-45 Low ambient control RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25 Compressor hard start kit SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 Compressor time delay RXMD-B01 RXMD-B01 RXMD-B01 RXMD-B01 RXMD-B01 RXMD-B01 RXMD-B01 Low pressure control RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 High pressure control RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 Liquid Line Solenoid (24 VAC, 50/60 Hz) Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC Solenoid Coil 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V Liquid Line Solenoid (120/240 VAC, 50/60 Hz) Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC Solenoid Coil 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V Classic Top Cap w/Label 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 *Crankcase Heater recommended with Low Ambient Kit. Weighted Sound Power Level (dBA) A-WEIGHTED SOUND POWER LEVEL (dBA) Unit Size - Voltage, Series Standard Rating (dBA) TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment) 125 250 500 1000 2000 4000 8000 RA1418 76.0 51.4 59.6 65.2 65.9 64.3 58.5 53.7 RA1424 75.0 50.0 59.5 63.2 64.4 61.4 56.8 52.6 RA1430 74.0 48.8 57.5 63.5 64 61.9 56.1 51 RA1436 76.0 52.2 61.3 65.4 65.3 62.4 57.3 53.1 RA1442 73.0 51.5 54.7 63.5 63.3 59.4 54.9 48.4 RA1448 76.0 52.3 59.1 66.7 65.7 62.4 59.3 55.9 RA1460 74.6 50.1 55.1 65.6 64.8 63.2 57.4 56.4 NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI) Unit Dimensions MODEL NO. OPERATING SHIPPING H (Height)L (Length)W (Width)H (Height)L (Length)W (Width) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm RA1418 25 635 29.75 755 29.75 755 26.75 679 32.38 822 32.38 822 RA1424 25 635 29.75 755 29.75 755 26.75 679 32.38 822 32.38 822 RA1430 27 685 29.75 755 29.75 755 28.75 730 32.38 822 32.38 822 RA1436 27 685 33.75 857 33.75 857 28.75 730 36.38 924 36.38 924 RA1442 35 889 33.75 857 33.75 857 36.75 933 36.38 924 36.38 924 RA1448 31 787 35.75 908 35.75 908 32.75 832 38.38 975 38.38 975 RA1460 51 1295 35.75 908 35.75 908 51.38 1305 38.38 975 38.38 975 ST-A1226-02-00 Air Unit Dimensions RA14 Series 10 [ ] Designates Metric Conversions 6 (152.4)24 (609.6)Service12 (304.8)6 (152.4)24 (609.6)Service24 (609.6)24 recommended12 minimum12 (304.8)12 (304.8)6 (152.4)24 (609.6)Service24 (609.6)Service24 (609.6)Service18 (457.2)WALLWALLWALLWALL NOTE: NUMBERS IN () = mmCLEARANCESIMPORTANT: When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate ventillation to prevent re-circulation of discharge air. ST-A1225-01-0024 (609.6)24 recommended12 minimum Air Clearances RA14 Series 11 FIGURE 2 CONTROL WIRING FOR GAS OR OIL FURNACE FOR TYPICAL ELECTRIC HEATFOR TYPICAL GAS OR OIL HEAT C Y G W R W/BL R W/BK G/BK YL BR PU YGW R TYPICAL THERMOSTAT SUBBASE TYPICAL GAS OR OIL FURNACE TYPICAL CONDENSING UNIT BR – BROWN WIRE YL – YELLOW WIRE X – WIRE CONNECTION BR –BROWN WIRE R –RED WIRE YL –YELLOW WIRE W/BK –WHITE WIRE WITH BLACK STRIPE G/BK –GREEN WIRE WITH BLACK STRIPE PU –PURPLE WIRE (NOT USED) X –WIRE CONNECTION *IF MAXIMUM OUTLET TEMPERATURE RISE IS DESIRED, IT IS RECOMMENDED THAT W1 (W/BK) AND W2 (W/BL) BE JUMPERED TOGETHER. YL BR TYPICAL CONDENSING UNIT YL BR X X X X X X X X X YGW R TYPICAL THERMOSTAT SUBBASE X TYPICAL ELECTRIC HEAT LOW VOLTAGE JUNCTION BOX •* Application Guidelines 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc. 2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C). 3. Maximum outdoor operating air temperature is 125°F (51.7°C). 4. For reliable operation, unit should be level in all horizontal planes. 5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. 6. Do not apply capillary tube indoor coils to these units. 7. Factory – supplied filter drier must be installed. Air Wiring Diagram/Application Guidelines RA14 Series 12 Control Wiring Air Refrigerant Line Size Information RA14 Series 1313 - 16 SEER Single-Stage Air-ConditionersUnit SizeAllowableLiquid LineSizeAllowableSuction LineSizeApply Long Line Guidelines ifLinear Line Length ExceedsThose Shown Below (Feet)Equivalent Length (Feet)< 2526-5051-7576-100101-125126-150151-175176-200201-225226-250(-)A13(-)A14A/B(-)A14W(-)A16Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) * / Capacity Multiplier1.5 Ton**SEENOTE 3 1/4" 5/8"N/RN/RN/RN/R25 / 1.0050 / 0.9962 / 0.9843 / 0.9824 / 0.975 / 0.97N/RN/RN/RN/R5/16"5/8"N/R22319818825 / 1.0050 / 0.9975 / 0.9898 / 0.9893 / 0.9788 / 0.9783 / 0.9678 / 0.9673 / 0.9568 / 0.943/8"5/8"17814813212525 / 1.0050 / 0.9975 / 0.98100 / 0.98100 / 0.97100 / 0.97100 / 0.96100 / 0.96100 / 0.95100 / 0.941/4" 3/4"**N/RN/RN/RN/R25 / 1.0050 / 1.0062 / 0.9943 / 0.9924 / 0.995 / 0.99N/RN/RN/RN/R5/16"3/4"**N/R22319818825 / 1.0050 / 1.0075 / 0.9998 / 0.9993 / 0.9988 / 0.9983 / 0.9978 / 0.9873 / 0.9868 / 0.983/8"3/4"**17814813212525 / 1.0050 / 1.0075 / 1.00100 / 0.99100 / 0.99100 / 0.99100 / 0.99100 / 0.98100 / 0.98100 / 0.982 Ton1/4" 5/8"N/RN/RN/RN/R25 / 0.9950 / 0.9821 / 0.97N/RN/RN/RN/RN/RN/RN/R5/16"5/8"24319317517525 / 0.9950 / 0.9875 / 0.9787 / 0.9677 / 0.9569 / 0.9461 / 0.9353 / 0.9245 / 0.9137 / 0.903/8"5/8"16212811711725 / 0.9950 / 0.9875 / 0.97100 / 0.96100 / 0.95100 / 0.9498 / 0.9395 / 0.9292 / 0.9189 / 0.901/4" 3/4"N/RN/RN/RN/R25 /1.0050 / 1.0021 / 0.99N/RN/RN/RN/RN/RN/RN/R5/16"3/4"24319317517525 /1.0050 / 1.0075 / 0.9987 / 0.9977 / 0.9869 / 0.9861 / 0.9853 / 0.9745 / 0.9737 / 0.963/8"3/4"16212811711725 / 1.0050 / 1.0075 / 0.99100 / 0.99100 / 0.98100 / 0.9898 / 0.9895 / 0.9793 / 0.9790 / 0.962.5 Ton5/16"5/8"N/RN/R11011025 / 0.9950 / 0.9875 / 0.9670 / 0.9459 / 0.9348 / 0.9136 / 0.90N/RN/RN/R3/8"5/8"142117737325 / 0.9950 / 0.9875 / 0.96100 / 0.9498 / 0.9394 / 0.9190 / 0.90N/RN/RN/R5/16"3/4"21317511011025 / 1.0050 / 0.9975 / 0.9970 / 0.9859 / 0.9848 / 0.9736 / 0.9625 / 0.9613 / 0.95N/R3/8"3/4"142117737325 / 1.0050 / 0.9975 / 0.99100 / 0.9898 / 0.9894 / 0.9790 / 0.9686 / 0.9682 / 0.9578 / 0.953 Ton5/16"5/8"N/RN/RN/RN/R25 / 0.9950 / 0.9766 / 0.9449 / 0.9232 / 0.90N/RN/RN/RN/RN/R3/8"5/8"10885908225 / 0.9950 / 0.9775 / 0.9495 / 0.9289 / 0.90N/RN/RN/RN/RN/R5/16"3/4"N/R12813512325 / 1.0050 / 0.9966 / 0.9849 / 0.9832 / 0.9715 / 0.96N/RN/RN/RN/R3/8"3/4"10885908225 / 1.0050 / 0.9975 / 0.9895 / 0.9889 / 0.9784 / 0.9678 / 0.9572 / 0.9467 / 0.9361 / 0.931/2"3/4"5443454125 / 1.0050 / 0.9975 / 0.98100 / 0.98100 / 0.97100 / 0.96100 / 0.95100 / 0.94100 / 0.93100 / 0.935/16"7/8"N/R12813512325 / 1.0050 / 1.0066 / 1.0049 / 0.9932 / 0.9915 / 0.99N/RN/RN/RN/R3/8"7/8"10885908225 / 1.0050 / 1.0075 / 1.0095 / 0.9989 / 0.9984 / 0.9978 / 0.9872 / 0.9867 / 0.9861 / 0.971/2"7/8"5443454125 / 1.0050 / 1.0075 / 1.00100 / 0.99100 / 0.99100 / 0.99100 / 0.98100 / 0.98100 / 0.98100 / 0.973.5 Ton3/8"3/4"150102757525 / 0.9950 / 0.9875 / 0.9788 / 0.9680 / 0.9572 / 0.9465 / 0.9257 / 0.9149 / 0.90N/R1/2"3/4"7551383825 / 0.9950 / 0.9875 / 0.97100 / 0.96100 / 0.95100 / 0.94100 / 0.92100 / 0.91100 / 0.90N/R3/8"7/8"150102757525 / 1.0050 / 1.0075 / 0.9988 / 0.9980 / 0.9972 / 0.9865 / 0.9757 / 0.9749 / 0.9642 / 0.961/2"7/8"7551383825 / 1.0050 / 1.0075 / 0.99100 / 0.99100 / 0.99100 / 0.98100 / 0.97100 / 0.97100 / 0.96100 / 0.96NOTES: 1.Do not exceed 200 ft linear line length.2.*Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.3. **3/4" suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.4.Always use the smallest liquid line allowable to minimize refrigerant charge.5.Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 6.Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. NOTE: Values based on 105°F liquid temperature and 45°F evaporator temperature in cooling mode depending on sizeRefrigerant Line Size Information Air Refrigerant Line Size Information RA14 Series 1413 - 16 SEER Single-Stage Air-ConditionersUnit SizeAllowableLiquid LineSizeAllowableSuction LineSizeApply Long Line Guidelines ifLinear Line Length ExceedsThose Shown Below (Feet)Equivalent Length (Feet)< 2526-5051-7576-100101-125126-150151-175176-200201-225226-250(-)A13(-)A14A/B(-)A14W(-)A16Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) * / Capacity Multiplier4 Ton3/8"3/4"148110N/R35 25 / 0.99 50 / 0.9875 / 0.9677 / 0.9567 / 0.9357 / 0.9246 / 0.91N/RN/RN/R1/2"3/4"7455N/R18 25 / 0.99 50 / 0.9875 / 0.96100 / 0.95100 / 0.93100 / 0.92100 / 0.91N/RN/RN/R3/8"7/8"148110N/R35 25 / 1.00 50 / 0.99 75 / 0.99 77 / 0.98 67 / 0.97 57 / 0.9746 / 0.9636 / 0.9626 / 0.9515 / 0.951/2"7/8"7455N/R18 25 / 1.00 50 / 0.99 75 / 0.99 100 / 0.98 100 / 0.97 100 / 0.97100 / 0.96100 / 0.9699 / 0.9597 / 0.955 Ton3/8"3/4"780N/R0 25 / 0.99 50 / 0.9775 / 0.9461 / 0.9246 / 0.90N/RN/RN/RN/RN/R1/2"3/4"390N/R0 25 / 0.99 50 / 0.9775 / 0.94100 / 0.92100 / 0.90N/RN/RN/RN/RN/R3/8"7/8"780N/R0 25 / 1.00 50 / 0.99 75 / 0.98 61 / 0.9746 / 0.9632 / 0.9518 / 0.94N/RN/RN/R1/2"7/8"390N/R0 25 / 1.00 50 / 0.99 75 / 0.98 100 / 0.97100 /0.96100 / 0.9597 / 0.9495 / 0.9492 / 0.9389 / 0.923/8"1-1/8"780N/R0 25 / 1.01 50 / 1.01 75 / 1.00 61 / 1.00 46 / 0.99 32 / 0.99 18 / 0.99N/RN/RN/R1/2"1-1/8"390N/R0 25 / 1.01 50 / 1.01 75 / 1.00 100 /1.00 100 / 0.99 100 / 0.99 97 / 0.99 95 / 0.99 92 / 0.99 89 / 0.98Refrigerant Line Size Information (con’t.)NOTES: 1.Do not exceed 200 ft linear line length.2.*Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.3. **3/4" suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.4.Always use the smallest liquid line allowable to minimize refrigerant charge.5.Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 6.Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. NOTE: Values based on 105°F liquid temperature and 45°F evaporator temperature in cooling mode depending on size 1513 - 16 SEER Single-Stage Air-ConditionersUnit SizeAllowableLiquid LineSizemm [in.]AllowableSuction LineSizemm [in.]Apply Long Line Guidelines ifLinear Line Length ExceedsThose Shown Below (Feet)Equivalent Length (Meters)< 88-1516-2324-3031-3839-4647-5354-6162-6970-76(-)A13(-)A14A/B(-)A14W(-)A16Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) * / Capacity Multiplier5.3 KW[1.5 Ton]**SEENOTE 3 6.35 [1/4]15.88 [5/8]N/RN/RN/RN/R8 / 1.00 15 / 0.99 19 / 0.98 13 / 0.98 7 / 0.97 2 / 0.97N/RN/RN/RN/R7.94 [5/16]15.88 [5/8]N/R686057 8 / 1.00 15 / 0.99 23 / 0.98 30 / 0.98 28 / 0.97 27 / 0.9725 / 0.9624 / 0.9622 / 0.9521 / 0.949.53 [3/8]15.88 [5/8]54454038 8 / 1.00 15 / 0.99 23 / 0.98 30 / 0.98 30 / 0.97 30 / 0.9730 / 0.9630 / 0.9630 / 0.9530 / 0.946.35 [1/4]**19.05 [3/4]**N/RN/RN/RN/R8 / 1.00 15 / 1.00 19 / 0.99 13 / 0.99 7 / 0.99 2 / 0.99N/RN/RN/RN/R7.94 [5/16]**19.05 [3/4]**N/R686057 8 / 1.00 15 / 1.00 23 / 0.99 30 / 0.99 28 / 0.99 27 / 0.99 25 / 0.99 24 / 0.98 22 / 0.98 21 / 0.989.53 [3/8]**19.05 [3/4]**54454038 8 / 1.00 15 / 1.00 23 / 0.99 30 / 0.99 30 / 0.99 30 / 0.99 30 / 0.99 30 / 0.98 30 / 0.98 30 / 0.987.0 KW[2 Ton]6.35 [1/4]15.88 [5/8]N/RN/RN/RN/R8 / 0.99 15 / 0.98 6 / 0.97N/RN/RN/RN/RN/RN/RN/R7.94 [5/16]15.88 [5/8]74595353 8 / 0.99 15 / 0.98 23 / 0.9727 / 0.9623 / 0.9521 / 0.9419 / 0.9316 / 0.9214 / 0.9111 / 0.909.53 [3/8]15.88 [5/8]49393636 8 / 0.99 15 / 0.98 23 / 0.9730 / 0.9630 / 0.9530 / 0.9430 / 0.9329 / 0.9228 / 0.9127 / 0.906.35 [1/4]19.05 [3/4]N/RN/RN/RN/R8 / 1.00 15 / 1.00 6 / 0.99N/RN/RN/RN/RN/RN/RN/R7.94 [5/16]19.05 [3/4]74595353 8 / 1.00 15 / 1.00 23 / 0.99 27 / 0.99 23 / 0.98 21 / 0.98 19 / 0.98 16 / 0.97 14 / 0.9711 / 0.969.53 [3/8]19.05 [3/4]49393636 8 / 1.00 15 / 1.00 23 / 0.99 30 / 0.99 30 / 0.98 30 / 0.98 30 / 0.98 29 / 0.97 28 / 0.9727 / 0.968.8 KW[2.5 Ton]7.94 [5/16]15.88 [5/8]N/RN/R3434 8 / 0.99 15 / 0.9823 / 0.9621 / 0.9418 / 0.9315 / 0.9111 / 0.90N/RN/RN/R9.53 [3/8]15.88 [5/8]43362222 8 / 0.99 15 / 0.9823 / 0.9630 / 0.9430 / 0.9329 / 0.9127 / 0.90N/RN/RN/R7.94 [5/16]19.05 [3/4]65533434 8 / 1.00 15 / 0.99 23 / 0.99 21 / 0.98 18 / 0.98 15 / 0.9711 / 0.968 / 0.964 / 0.95N/R9.53 [3/8]19.05 [3/4]43362222 8 / 1.00 15 / 0.99 23 / 0.99 30 / 0.98 30 / 0.98 29 / 0.9727 / 0.9626 / 0.9625 / 0.9524 / 0.9510.6 KW[3 Ton]7.94 [5/16]15.88 [5/8]N/RN/RN/RN/R8 / 0.99 15 / 0.9720 / 0.9415 / 0.9210 / 0.90N/RN/RN/RN/RN/R9.53 [3/8]15.88 [5/8]33262725 8 / 0.99 15 / 0.9723 / 0.9429 / 0.9227 / 0.90N/RN/RN/RN/RN/R7.94 [5/16]19.05 [3/4]N/R394137 8 / 1.00 15 / 0.99 20 / 0.98 15 / 0.98 10 / 0.975 / 0.96N/RN/RN/RN/R9.53 [3/8]19.05 [3/4]33262725 8 / 1.00 15 / 0.99 23 / 0.98 29 / 0.98 27 / 0.9726 / 0.9624 / 0.9522 / 0.9420 / 0.9319 / 0.9312.70 [1/2]19.05 [3/4]17131412 8 / 1.00 15 / 0.99 23 / 0.98 30 / 0.98 30 / 0.9730 / 0.9630 / 0.9530 / 0.9430 / 0.9330 / 0.937.94 [5/16]22.23 [7/8]N/R394137 8 / 1.00 15 / 1.00 20 / 1.00 15 / 0.99 10 / 0.99 5 / 0.99N/RN/RN/RN/R9.53 [3/8]22.23 [7/8]33262725 8 / 1.00 15 / 1.00 23 / 1.00 29 / 0.99 27 / 0.99 26 / 0.99 24 / 0.98 22 / 0.98 20 / 0.98 19 / 0.9712.70 [1/2]22.23 [7/8]17131412 8 / 1.00 15 / 1.00 23 / 1.00 30 / 0.99 30 / 0.99 30 / 0.99 30 / 0.98 30 / 0.98 30 / 0.98 30 / 0.9712.3 KW[3.5 Ton]9.53 [3/8]19.05 [3/4]46312323 8 / 0.99 15 / 0.98 23 / 0.9727 / 0.9624 / 0.9522 / 0.9420 / 0.9217 / 0.9115 / 0.90N/R12.70 [1/2]19.05 [3/4]23151111 8 / 0.99 15 / 0.98 23 / 0.9730 / 0.9630 / 0.9530 / 0.9430 / 0.9230 / 0.9130 / 0.90N/R9.53 [3/8]22.23 [7/8]46312323 8 / 1.00 15 / 1.00 23 / 0.99 27 / 0.99 24 / 0.99 22 / 0.98 20 / 0.97 17 / 0.9715 / 0.9613 / 0.9612.70 [1/2]22.23 [7/8]23151111 8 / 1.00 15 / 1.00 23 / 0.99 30 / 0.99 30 / 0.99 30 / 0.98 30 / 0.97 30 / 0.9730 / 0.9630 / 0.96NOTES: 1.Do not exceed 61 meters linear line length.2.*Do not exceed 30 meters vertical separation if outdoor unit is above indoor unit.3. **19.05 mm [3/4 in.] suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.4.Always use the smallest liquid line allowable to minimize refrigerant charge.5.Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 6.Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. [ ] Designates Metric Conversions Air Refrigerant Line Size Information RA14 Series Refrigerant Line Size Information (con’t.) Air Refrigerant Line Size Information RA14 Series 16Refrigerant Line Size Information (con’t.)NOTES: 1.Do not exceed 61 meters linear line length.2.*Do not exceed 30 meters vertical separation if outdoor unit is above indoor unit.3. **19.05 mm [3/4 in.] suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.4.Always use the smallest liquid line allowable to minimize refrigerant charge.5.Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 6.Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. [ ] Designates Metric Conversions13 - 16 SEER Single-Stage Air-ConditionersUnit SizeAllowableLiquid LineSizeAllowableSuction LineSizeApply Long Line Guidelines ifLinear Line Length ExceedsThose Shown Below (Feet)Equivalent Length (Meters)< 88-1516-2324-3031-3839-4647-5354-6162-6970-76(-)A13(-)A14A/B(-)A14W(-)A16Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) * / Capacity Multiplier14.1 KW[4 Ton]9.53 [3/8]19.05 [3/4]4534N/R11 8 / 0.99 15 / 0.9823 / 0.9624 / 0.9520 / 0.9317 / 0.9214 / 0.91NRNRNR12.7 [1/2]19.05 [3/4]2317N/R5 8 / 0.99 15 / 0.9823 / 0.9630 / 0.9530 / 0.9330 / 0.9230 / 0.91NRNRNR9.53 [3/8]22.23 [7/8]4534N/R11 8 / 1.00 15 / 0.99 23 / 0.99 24 / 0.98 20 / 0.97 17 / 0.9714 / 0.9611 / 0.968 / 0.955 / 0.9512.7 [1/2]22.23 [7/8]2317N/R5 8 / 1.00 15 / 0.99 23 / 0.99 30 / 0.98 30 / 0.97 30 / 0.9730 / 0.9630 / 0.9630 / 0.9530 / 0.9517.6 KW[5 Ton]9.53 [3/8]19.05 [3/4]2417N/R0 8 / 0.99 15 / 0.9723 / 0.9419 / 0.9214 / 0.90NRNRNRNRNR12.7 [1/2]19.05 [3/4]128N/R0 8 / 0.99 15 / 0.9723 / 0.9430 / 0.9230 / 0.90NRNRNRNRNR9.53 [3/8]22.23 [7/8]2417N/R0 8 / 1.00 15 / 0.99 23 / 0.98 19 / 0.9714 / 0.9610 / 0.955 / 0.94NRNRNR12.7 [1/2]22.23 [7/8]128N/R0 8 / 1.00 15 / 0.99 23 / 0.98 30 / 0.9730 /0.9630 / 0.9530 / 0.9429 / 0.9428 / 0.9327 / 0.929.53 [3/8]28.58 [1-1/8]2417N/R0 8 / 1.01 15 / 1.01 23 / 1.00 19 / 1.00 14 / 0.99 10 / 0.99 5 / 0.99NRNRNR12.7 [1/2]28.58 [1-1/8]128N/R0 8 / 1.01 15 / 1.01 23 / 1.00 30 / 1.00 30 / 0.99 30 / 0.99 30 / 0.99 29 / 0.99 28 / 0.99 27 / 0.98 17 Air Performance Data RA14 Series Tested Combination Outdoor Unit Indoor Coil Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW]SEER EER Indoor CFM [L/s] RA1418AJ1 RCF2417STA+RXMD-C04 17800 [5.2]12100 [3.5] 5700 [1.7]14.00 11.50 600 [283.2] RA1424BJ1 RCF2417STA+RXMD-C04 23200 [6.8]17500 [5.2] 5700 [1.7]14.00 11.50 800 [376.0] RA1430AJ1 RCF3617STA+RXMD-C04 28800 [8.4]19500 [5.7] 9300 [2.7]14.00 11.50 1000 [471.9] RA1436AJ1 RCF3617STA+RXMD-C04 34200 [10.0]23200 [6.8]11000 [3.2]14.00 11.50 1050 [495.5] RA1436AC1 RCF3617STA+RXMD-C04 34200 [10.0]23200 [6.8]11000 [3.2]14.00 11.50 1050 [495.5] RA1436AD1 RCF3617STA+RXMD-C04 34200 [10.0]23200 [6.8]11000 [3.2]14.00 11.50 1050 [495.5] RA1442CJ1 RCF4821STA+RXMD-C04 39500 [11.6]28900 [8.5]10600 [3.1]14.00 11.50 1350 [634.5] RA1442CC1 RCF4821STA+RXMD-C04 39500 [11.6]28900 [8.5]10600 [3.1]14.00 11.50 1350 [634.5] RA1448AJ1 RCF4821STA+RXMD-C04 46000 [13.5]31200 [9.1]14800 [4.3]14.00 11.70 1450 [684.3] RA1448AC1 RCF4821STA+RXMD-C04 46000 [13.5]31200 [9.1]14800 [4.3]14.00 11.70 1450 [684.3] RA1448AD1 RCF4821STA+RXMD-C04 46000 [13.5]31200 [9.1]14800 [4.3]14.00 11.70 1450 [684.3] RA1460BJ1 RCF6024STA+RXMD-C04 55500 [16.3]38100 [11.2]17400 [5.1]14.00 11.70 1525 [716.8] RA1460AD1 RCF6024STA+RXMD-C04 55500 [16.3]38100 [11.2]17400 [5.1]14.00 11.70 1525 [716.8] RA1460BC1 RCF6024STA+RXMD-C04 55500 [16.3]38100 [11.2]17400 [5.1]14.00 11.70 1525 [716.8] Note: Additional ratings and system match ups can be accessed on MyRheem.com at: https://my.rheem.com/static/private/ahriresidential.html Additional ratings and system match ups and downloadable ratings certificates can be accessed from the AHRI website: www.ahridirectory.org [ ] Designates Metric Conversions Performance Data @ AHRI Standard Conditions – Cooling Air Guide Specifications RA14 Series 18 GUIDE SPECIFICATIONS General System Description Outdoor-mounted, air-cooled, split-system air conditioner com- posite base pan unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air-cooled coil, pro- peller-type condenser fan, suction and legend line service valve, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a coil unit. Quality Assurance — Unit will be rated in accordance with the latest edition of AHRI Standard 210. — Unit will be certified for capacity and efficiency, and listed in the latest AHRI directory. — Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC. — Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c-UL-us approval. — Unit cabinet will be capable of withstanding ASTM B117 1000- hr salt spray test. — Air-cooled condenser coils will be leak tested at 150 psig and pressure tested at 550 psig. — Unit constructed in ISO9001 approved facility. Delivery, Storage, and Handling — Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendations. Warranty (for inclusion by specifying engineer) — U.S. and Canada only. Products Equipment Factory assembled, single piece, air-cooled air conditioner unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge R-410A, and special fea- tures required prior to field start-up. Unit Cabinet — Unit cabinet will be constructed of galvanized steel, bonder- ized, and coated with a powder coat paint. — All units constructed with louver coil protection and corner post. Louver can be removed by removing one fastener per louver panel. AIR-COOLED, SPLIT-SYSTEM AIR CONDITIONER RA14 1-1/2 TO 5 NOMINAL TONS Fans — Condenser fan will be direct-drive propeller type, discharging air upward. — Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant. — Fan blades will be statically and dynamically balanced. — Condenser fan openings will be equipped with coated steel wire safety guards. Compressor — Compressor will be hermetically sealed. — Compressor will be mounted on rubber vibration isolators. Condenser Coil — Condenser coil will be air cooled. — Coil will be constructed of aluminum fins mechanically bonded to copper tubes. Refrigeration Components — Refrigeration circuit components will include liquid-line shutoff valve with sweat connections, vapor-line shutoff valve with sweat connections, system charge of R-410A refrigerant, and compressor oil. — Unit will be equipped with filter drier for R-410A refrigerant for field installation. Operating Characteristics — The capacity of the unit will meet or exceed _____ Btuh at a suction temperature of _____ °F/°C. The power consumption at full load will not exceed _____ kW. — Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of _____ Btuh or greater at conditions of _____ CFM entering air temperature at the evap- orator at _____ °F/°C wet bulb and _____ °F/°C dry bulb, and air entering the unit at _____ °F/°C. — The system will have a SEER of _____ Btuh/watt or greater at DOE conditions. Electrical Requirements — Nominal unit electrical characteristics will be _____ v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v. — Nominal unit electrical characteristics will be _____ v, three phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. 19 Air Limited Warranty RA14 Series GENERAL TERMS OF LIMITED WARRANT Y* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Conditional Parts (Registration Required)...............................Ten (10) Years The new degree of comfort.™ Rheem Heating, Cooling & Water Heating • 5600 Old Greenwood Road Fort Smith, Arkansas 72908 • www.rheem.com In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. PRINTED IN U.S.A. 6/19 QG FORM NO. A11-220 REV. 9 Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario • L6Y 0P5