Rheem Classic® Series
Air Conditioners
FORM NO. A11-220 REV. 9
•Composite base pan – dampens sound, captures louver
panels, eliminates corrosion and reduces number of fasteners
needed
•Powder coat paint system – for a long lasting professional finish
•Scroll compressor – uses 70% fewer moving parts for higher
efficiency and increased reliability
•Modern cabinet aesthetics – increased curb appeal with visu-
ally appealing design
•Curved louver panels – provide ultimate coil protection,
enhance cabinet strength, and increased cabinet rigidity
•Optimized fan orifice – optimizes airflow and reduces unit
sound
•Rust resistant screws – confirmed through 1500-hour salt
spray testing
•PlusOne™ Expanded Valve Space – 3"-4"-5" service valve
space – provides a minimum working area of 27-square
inches for easier access
•PlusOne™ Triple Service Access – 15" wide, industry lead-
ing corner service access – makes repairs easier and faster.
The two fastener removable corner allows optimal access to
internal unit components. Individual louver panels come out
once fastener is removed, for faster coil cleaning and easier
cabinet reassembly
•Diagnostic service window with two-fastener opening –
provides access to the high and low pressure.
•External gauge port access – allows easy connection of
“low-loss” gauge ports
•Single-row condenser coil – makes unit lighter and allows
thorough coil cleaning to maintain “out of the box”
performance
•35% fewer cabinet fasteners and fastener-free base – allow
for faster access to internal components and hassle-free
panel removal
•Service trays – hold fasteners or caps during service calls
•QR code – provides technical information on demand for
faster service calls
•Fan motor harness with extra long wires allows unit top to be
removed without disconnecting fan wire.
Air Air Conditioners
RA14 Series
“Proper sizing and installation of equipment is critical to achieve optimal
performance. Split system air conditioners and heat pumps must be
matched with appropriate coil components to meet Energy Star.
Ask your Contractor for details or visit www.energystar.gov.”
RA14 Series
Efficiencies up to 14 SEER /11.5 EER
Nominal Sizes 11/2 to 5 Ton [5.28 to 17.6 kW]
Cooling Capacities 17.3 to 60.5 kBTU
[5.7 to 17.7 kW]
Air Table of Contents
RA14 Series
2
TABLE OF CONTENTS
Standard Feature ......................................................................................................3
Available SKUs ........................................................................................................3
Features & Benefits ..............................................................................................4-5
Model Number Identification ................................................................................6-7
General Data/Electrical Data ....................................................................................8
Accessories ............................................................................................................9
Weighted Sound Power ............................................................................................9
Unit Dimensions......................................................................................................10
Clearances ..............................................................................................................11
Wiring Diagrams ....................................................................................................12
Application Guidelines ............................................................................................12
Refrigerant Line Size Information ......................................................................13-16
Performance Data ..................................................................................................17
Guide Specifications ..............................................................................................18
Limited Warranty ....................................................................................................19
Air Standard Feature/Available SKUs
RA14 Series
3
STANDARD FEATURES
Feature 18 24 30 36 42 48 60
R-410a Refrigerant √√√√√√√
Maximum SEER 15.5 15 15.5 15.5 15 15 14
Maximum EER 13 13 13 13 13 13 12
Scroll Compressor √√√√√√√
Field Installed Filter Drier √√√√√√√
Front Seating Service Valves √√√√√√√
Internal Pressure Relief Valve √√√√√√√
Internal Thermal Overload √√√√√√√
Long Line capability √√√√√√√
Low Ambient capability with Kit √√√√√√√
3-4-5 Expanded Valve Space √√√√√√√
Composite Basepan √√√√√√√
2 Screw Control Box Access √√√√√√√
15" Access to Internal Components √√√√√√√
Quick release louver panel design √√√√√√√
No fasteners to remove along bottom √√√√√√√
Optimized Venturi Airflow √√√√√√√
Single row condenser coil √√√√√√√
Powder coated paint √√√√√√√
Rust resistant screws √√√√√√√
QR code √√√√√√√
External gauge ports √√√√√√√
Service trays √√√√√√√
√ = Standard
Standard Feature Table
Available Models Description
RA1418AJ1NA Classic ® Series 1 1/2 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60
RA1418AJ1NB Classic ® Series 1 1/2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1424BJ1NA Classic ® Series 2 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60
RA1424BJ1NB Classic ® Series 2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1430AJ1NA Classic ® Series 2 1/2 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60
RA1430AJ1NB Classic ® Series 2 1/2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1436AC1NB Classic ® Series 3 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1436AD1NB Classic ® Series 3 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-460/3/60
RA1436AJ1NA Classic ® Series 3 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60
RA1436AJ1NB Classic ® Series 3 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1442AD1NB Classic ® Series 3 1/2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-460/3/60
RA1442CC1NB Classic ® Series 3 1/2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1442CJ1NA Classic ® Series 3 1/2 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60
RA1442CJ1NB Classic ® Series 3 1/2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1448AC1NB Classic ® Series 4 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1448AD1NB Classic ® Series 4 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-460/3/60
RA1448AJ1NA Classic ® Series 4 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60
RA1448AJ1NB Classic ® Series 4 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1460AD1NB Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-460/3/60
RA1460BC1NB Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1460BJ1NA Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60
RA1460BJ1NB Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1460CC1NB Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1460CD1NB Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-460/3/60
RA1460CJ1NA Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60
RA1460CJ1NB Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
Available SKUs
The RA14 is our 14 SEER air conditioner and is part of the
Rheem air conditioner product line that extends from 13 to 20
SEER. This highly featured and reliable air conditioner is
designed for years of reliable, efficient operation when matched
with Rheem indoor aluminum evaporator coils and furnaces or
air handler units with aluminum evaporators.
Our unique composite base () reduces sound emission, elimi-
nates rattles, significantly reduces fasteners, eliminates corro-
sion and has integrated brass compressor attachment inserts
(). Furthermore it has incorporated into the design, water
management features, means for hand placement () for unit
maneuvering, screw trays () and inserts for lifting off unit
pad. ()
Service Valves () are rigidly mounted in the composite base
with 3" between suction and discharge valves, 4" clearance
below service valves and a minimum of 5" above the service
valves, creating industry leading installation ease. The minimum
27 square-inches around the service valves allows ample room
to remove service valve schrader prior to brazing, plenty of clear-
ance for easy brazing of the suction and discharge lines to ser-
vice valve outlets, easy access and hookup of low loss refriger-
ant gauges (), and access to the service valve caps for
opening. For applications with long-line lengths up to 250 feet
total equivalent length, up to 200 feet condenser above evapora-
tor, or up to 80 feet evaporator above condenser, the long-line
instructions in the installation manual should be followed.
Controls are accessed from the corner of the unit by removing
only two fasteners from the control access cover, revealing the
industry’s largest 15" wide and 14" tall control area (). With all
this room in the control area the high voltage electrical whip ()
can easily be inserted through the right size opening in the bot-
tom of the control area. Routing it leads directly to contractor
lugs for connection. The low voltage control wires () are easily
connected to units low voltage wiring. If contactor or capacitor
() needs to be replaced there is more than adequate space to
make the repair. Furthermore, if high pressure and low pressure
model was not purchased but is desired to be installed in the
field, the service window () can be removed by removing two
screws, to access the high and low side schrader fittings for easy
field installation. The entire corner can be removed providing
ultimate access to install the high and low pressure switch. ()
If in the rare event, greater access is needed to internal compo-
nents, such as the compressor, the entire corner of the unit can
be removed along with the top cover assembly to have unprece-
dented access to interior of the unit (). Extra wire length is
incorporated into each outdoor fan and compressor so top
cover and control panel can be positioned next to the unit. With
minimal effort the plug can be removed from the compressor
and the outdoor fan wires can be removed from the capacitor to
allow even more uncluttered access to the interior of the unit ().
Outdoor coil heights range from as short as 22" to 32", aiding
access to the compressor. Disassembly to this degree and com-
plete reassembly only takes a first time service technician less
than 10 minutes. ()
All units utilize strong formed louver panels which provide indus-
try leading coil protection. Louver removal for coil cleaning is
accomplished by removing one screw and lifting the panel out of
the composite base pan. () All RA14 units utilize single row
coils () making cleaning easy and complete, restoring the
performance of the air conditioner back to out of the box perfor-
mance levels year after year.
The outdoor fan motor has sleeve bearings and is inherently
protected. The motor is totally enclosed for maximum protection
from weather, dust and corrosion. Access to the outdoor fan is
made by removing four fasteners from the fan grille. The outdoor
fan can be removed from the fan grille by removing 4 fasteners
in the rare case outdoor fan motor fails.
Each cabinet has optimized composite () fan orifice assuring
efficient and quiet airflow.
1
2
3
4
7
8
9
10
12
13
6
11
5
14
15
15
17
16
19
Air Features & Benefits
RA14 Series
4
Introduction to RA14 Air Conditioner
1
4
64 3 5
2
8 11
910
13
12
19
7 17
16
14
18
15
Air Features & Benefits
RA14 Series
5
The entire cabinet has powder post paint () achieving 1000
hour salt spray rating, allowing the cabinet to retain its aesthetics
throughout its life.
Scroll compressors with standard internal pressure relief and
internal thermal overload are used on all capacities assuring
longevity of high efficient and quiet operation for the life of the
product.
Each unit is shipped with filter drier for field installation and will
trap any moisture or dirt that could contaminate the refrigerant
system.
All cabinets have industry leading structural strength due to the
composite base pan (), interlocking corner post (), formed
curved louver panels () and drawn top cover () making it
the most durable cabinet on the market today.
Each RA14 capacity has undergone rigorous psychometric test-
ing to assure performance ratings of capacity, SEER and EER
per AHRI Standard 210/240 rating conditions. Also
each unit bears the UL mark and each unit is certified
to UL 1995 safety standards.
Each unit has undergone specific strain and modal testing to
assure tubing () is outside the units natural frequency and that
the suction and discharge lines connected to the compressor
withstand any starting, steady state operation or shut down
forces imposed by the compressor.
All units have been sound tested in sound chamber to AHRI 270
rating conditions, and A-weighted Sound Power Level tables
produced, assuring units have acceptable noise qualities (see
page 9). Each unit has been ran in cooling operation at 95°F and
82°F and sound ratings for the RA14 range from as low as 74
dBA to 77 dBA.
All units have been ship tested to assure units meet stringent
“over the road” shipping conditions.
As manufactured all units in the RA14 family have cooling capa-
bility to 55 °F. Addition of low ambient control will allow the unit
to operate down to 0°F. Factory testing is performed on each
unit. All component parts meet well defined specification and
continually go through receiving inspections. Each component
installed on a unit is scanned, assuring correct component uti-
lization for a given unit capacity and voltage. All condenser coils
are leak tested with pressurization test to 550#’s and once
installed and assembled, each units’ complete refrigerant
system is helium leak tested. All units are fully charged from the
factory for up to 15 feet of piping. All units are factory run tested.
The RA14 has a 10-year conditional compressor and parts war-
ranty (registration required).
Optional Accessories
(Refer to accessory chart for model #)
Compressor Crankcase Heater
Protects against refrigerant migration that can occur during low
ambient operation
Compressor Sound Cover
• Reinforced vinyl compressor cover containing a 1½ inch thick
batt of fiberglass insulation
• Open edges are sealed with a one-inch wide hook and loop
fastening tape
Compressor Hard Start Kit
• Single-phase units are equipped with a PSC compressor
motor, this type of motor normally does not need a potential
relay and start capacitor
• Kit may be required to increase the compressor starting
torque, in conditions such as low voltage
Low Ambient Kit
• Air conditioners operate satisfactorily in the cooling mode
down to 55°F outdoor air temperature without any additional
controls
• This Kit can be added in the field enabling unit to operate
properly down to 0° in the cooling mode
• Crankcase heater and freezestat should be installed on com-
pressors equipped with a low ambient kit
3"/6"/12"
• Gray high density polyethylene feet are available to raise unit
off of mounting surface away from moisture
Low Pressure
• Can be added in field enabling the unit to shut off compressor
on loss of charge
NOTE: Unit can be purchased with high and low pressure
installed at factory. (Refer to SKU list)
High Pressure
• Can be added in field enabling unit to shut off compressor if
unit loses outdoor fan operation.
NOTE: Unit can be purchased with high and low pressure
installed at factory. (Refer to SKU list)
Decorative Top
• Can be installed on fan grille
25
20
2221
2423
20
24
23
22
21
25
RA1424AJ1NA*BrandProduct CategorySEERCapacity BTU/HRMajor Series*VoltageTypeControlsMinor Series**Option CodeRheem A - Air Conditioners 14 - 14 SEER18 - 18,000 [5.28 kW] 24 - 24,000 [7.03 kW] 30 - 30,000 [8.79 kW] 36 - 36,000 [10.55 kW] 42 - 42,000 [12.31 kW] 48 - 48,000 [14.07 kW] 60 - 60,000 [17.58 kW] A - 1st Design B - 2nd DesignJ - 1ph, 208-230/60 C - 3ph, 208-230/60 D - 3ph, 460/60 1 - Single-stageN - Non-CommunicatingA - 1st Design B - 2nd DesignN/ARP1424AJ1NA*BrandProductCategorySEERCapacityBTU/HRMajor Series*VoltageTypeControlsMinor Series**Option CodeRheem P - Heat Pump 13 - 13 SEER14 - 14 SEER16 - 16 SEER17 - 17 SEER20 - 20 SEER18 - 18,000 [5.28 kW]24 - 24,000 [7.03 kW]30 - 30,000 [8.79 kW]36 - 36,000 [10.55 kW]42 - 42,000 [12.31 kW]48 - 48,000 [14.07 kW]60 - 60,000 [17.58 kW]A - 1st DesignJ - 1ph, 208-230/60C - 3ph, 208-230/60D - 3ph, 460/601 - Single-stage2 - Two-stageV - InverterP - PistonC - CommunicatingN - Non-CommunicatingA - 1st DesignN/ARCF2417STAMCA*BrandProductCategoryTypeCapacityBTU/HRWidthEfficiencyMeteringDeviceMajorSeries*OrientationCasingMinor Series**OptionCodeRheem C - Evap CoilF - Furn CoilH - Air-HandlerCoil24 - 24,000 [7.03 kW]36 - 36,000 [10.55 kW]48 - 48,000 [14.07 kW]60 - 60,000 [17.58 kW]14 - 14"17 - 17.5"21 - 21"24 - 24.5"S- Standard Eff.M- Mid Eff.H- High Eff.T-TXVE-EEVP-PistonA - 1st DesignM - MultipoiseV - Vertical only/convertibleH - Ded.Horizontal onlyC - CasedU - UncasedA - 1st DesignN/A Air Model Number Identification
RA14 Series
6 Heat Pumps (For Reference)** Furnace Coils (For Reference)** Air Conditioners**See page 3 for available SKU’s.**Model number ID’s are for reference only. Available SKU’s are listed on the standard features/available SKU page of model spec sheets. [ ] Designates Metric Conversions
R96VA702317MSABrandSeriesMotorMajor RevInputBTU/HRStagesAir FlowCabinetWidthConfigurationNoxMinor RevRheem 90 - 90 AFUE92 - 92 AFUE95 - 95 AFUE96 - 96 AFUE97 - 97 AFUEV - Variable speedT - ConstantTorque(X-13)P - PSCA - 1st Design040 - 42,000 [12.31 kW]060 - 56,000 [16.41 kW]070 - 70,000 [20.51 kW]085 - 84,000 [24.62 kW]100 - 98,000 [28.72 kW]115 - 112,000 [32.82 kW]1 -Single-stage2 -Two-stageM - Modulating3 - up to 3 ton5 - 3 1/2 up to 5 ton14 - 14"17 - 17.5"21 - 21"24 - 24.5"M - MultiX - Low NoxS - StandardA - 1st Design Air Model Number Identification
RA14 Series
7R802VA075317MSABrandSeriesStagesMotorMajor RevInputBTU/HRAir FlowCabinetWidthConfigurationNoxMinor RevRheem 80 - 80+ AFUE1 - Single-stage2 - Two-stageV - Variable speedT - Constant Torque (X-13)P - PSC premiumS - PSC standardA - 1st Design050 - 50,000 [15 kW]075 - 75,000 [22 kW]100 - 100,000 [29 kW]125 - 125,000 [37 kW]150 - 150,000 [44 kW]3 - up to 3 ton4 - 2 1/2 to 4 ton5 - 3 1/2 up to 5 ton14 - 14"17 - 17.5"21 - 21"24 - 24.5"M- MultiD- DownZ - Down &zero clearancedown flowX - Low NoxS - StandardA - 1st DesignRH1T3617STANAA000*BrandProductCategoryStages ofAirflowMotor TypeCapacityBTU/HRWidthCoil SizeMetering DeviceMajorSeries*ControlsVoltageMinorSeries**Factory HeatCapOptionCodeRheem H - AirHandler1 - Single-Stage2 - Two-StageM - ModulatingV - VariableSpeedT - ConstantTorqueP - PSC 24 - 24,000 [7.03 kW]36 - 36,000 [10.55 kW]48 - 48,000 [14.07 kW]60 - 60,000 [17.58 kW]14 - 14"17 - 17.5"21 - 21"24 - 24.5"S - StandardEff.M -Mid Eff.H - High Eff.T - TEVE - EEVP - PistonA - 1st DesignC -CommunicatingN -Non-commA - 1ph, 115/60J - 1ph, 208-240/60D - 3ph, 480/60A - 1st Design00 - nofactory heatwith optioncode*TBD 90%+ AFUE Gas Furnaces (For Reference)** 80% AFUE Gas Furnaces (For Reference)** Air Handlers (For Reference)****Model number ID’s are for reference only. Available SKU’s are listed on the standard features/available SKU page of model spec sheets. [ ] Designates Metric Conversions
Air General Data/Electrical Data
RA14 Series
8
Physical Data
PHYSICAL DATA
Model No.RA1418 RA1424 RA1430 RA1436 RA1442 RA1448 RA1460
Nominal Tonnage 1.5 2.0 2.5 3.0 3.5 4.0 5.0
Valve Connections
Liquid Line O.D. – in.3/8 3/8 3/8 3/8 3/8 3/8 3/8
Suction Line O.D. – in.3/4 3/4 3/4 3/4 7/8 7/8 7/8
Refrigerant (R410A) furnished oz.¹68 80 87 106 134 129 201
Compressor Type Scroll
Outdoor Coil
Net face area – Outer Coil 9.1 11.1 12.1 14.8 17.3 18.9 32.3
Net face area – Inner Coil ———————
Tube diameter – in.3/8 3/8 3/8 3/8 3/8 3/8 3/8
Number of rows 1 1 1 1 1 1 1
Fins per inch 22 22 22 22 22 22 22
Outdoor Fan
Diameter – in. 20 20 20 24 24 26 26
Number of blades 2 2 2 3 3 2 3
Motor hp 1/10 1/8 1/8 1/6 1/5 1/5 1/3
CFM 2225 2295 2605 3105 4105 4264 4775
RPM 1075 1121 1075 850 833 820 795
watts 130 138 142 173 236 236 239
Shipping weight – lbs. 143 148 158 178 207 232 247
Operating weight – lbs.122 141 151 171 200 221 240
Electrical Data
Line Voltage Data (Volts-Phase-Hz)208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
Maximum overcurrent protection (amps)²20 25 25 30 35 45 50
Minimum circuit ampacity³13 15 17 19 23 27 34
Compressor
Rated load amps 9.7 10.9 12.8 14.1 16.7 19.9 23.7
Locked rotor amps 48 62.9 64 77 109 109 152.5
Condenser Fan Motor
Full load amps 0.6 0.8 0.8 0.8 1.2 1.2 3.5
Locked rotor amps 1.1 1.5 1.4 1.5 2.0 2.3 -
Line Voltage Data (Volts-Phase-Hz)———208/230-3-60 208/230-3-61 208/230-3-62 208/230-3-63
Maximum overcurrent protection (amps)²———20 25 30 35
Minimum circuit ampacity³———13 16 18 24
Compressor
Rated load amps ———9 11.2 13.1 15.9
Locked rotor amps ———71 84 83.1 110
Condenser Fan Motor
Full load amps ———0.8 1.2 1.2 3.5
Locked rotor amps ———1.5 3.0 2.3 -
Line Voltage Data (Volts-Phase-Hz)———480-3-60 480-3-60
RA1442AD 480-3-60 480-3-60
RA1460AD
Maximum overcurrent protection (amps)²———15 —15 15
³Minimum circuit ampacity ———8 —9 10
Compressor
Rated load amps ———5.6 —6.1 7.1
Locked rotor amps ———38 —41 52
Condenser Fan Motor
Full load amps ———0.5 —0.6 0.5
Locked rotor amps ———1.1 —1.6 1.4
¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional
refrigerant charge required.
²HACR type circuit breaker of fuse.
³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
Air Accessories/Weighted Sound Power
RA14 Series
9
Accessories
Model No.RA1418 RA1424 RA1430 RA1436 RA1442 RA1448 RA1460
Compressor crankcase heater*44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 44-17402-45
Low ambient control RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08
Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25
Compressor hard start kit SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1
Compressor time delay RXMD-B01 RXMD-B01 RXMD-B01 RXMD-B01 RXMD-B01 RXMD-B01 RXMD-B01
Low pressure control RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07
High pressure control RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07
Liquid Line Solenoid
(24 VAC, 50/60 Hz)
Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC
Solenoid Coil 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V
Liquid Line Solenoid
(120/240 VAC, 50/60 Hz)
Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC
Solenoid Coil 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V
Classic Top Cap w/Label 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21
*Crankcase Heater recommended with Low Ambient Kit.
Weighted Sound Power Level (dBA)
A-WEIGHTED SOUND POWER LEVEL (dBA)
Unit Size - Voltage, Series Standard
Rating (dBA)
TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
125 250 500 1000 2000 4000 8000
RA1418 76.0 51.4 59.6 65.2 65.9 64.3 58.5 53.7
RA1424 75.0 50.0 59.5 63.2 64.4 61.4 56.8 52.6
RA1430 74.0 48.8 57.5 63.5 64 61.9 56.1 51
RA1436 76.0 52.2 61.3 65.4 65.3 62.4 57.3 53.1
RA1442 73.0 51.5 54.7 63.5 63.3 59.4 54.9 48.4
RA1448 76.0 52.3 59.1 66.7 65.7 62.4 59.3 55.9
RA1460 74.6 50.1 55.1 65.6 64.8 63.2 57.4 56.4
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)
Unit Dimensions
MODEL
NO.
OPERATING SHIPPING
H (Height)L (Length)W (Width)H (Height)L (Length)W (Width)
INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm
RA1418 25 635 29.75 755 29.75 755 26.75 679 32.38 822 32.38 822
RA1424 25 635 29.75 755 29.75 755 26.75 679 32.38 822 32.38 822
RA1430 27 685 29.75 755 29.75 755 28.75 730 32.38 822 32.38 822
RA1436 27 685 33.75 857 33.75 857 28.75 730 36.38 924 36.38 924
RA1442 35 889 33.75 857 33.75 857 36.75 933 36.38 924 36.38 924
RA1448 31 787 35.75 908 35.75 908 32.75 832 38.38 975 38.38 975
RA1460 51 1295 35.75 908 35.75 908 51.38 1305 38.38 975 38.38 975
ST-A1226-02-00
Air Unit Dimensions
RA14 Series
10
[ ] Designates Metric Conversions
6 (152.4)24 (609.6)Service12 (304.8)6 (152.4)24 (609.6)Service24 (609.6)24 recommended12 minimum12 (304.8)12 (304.8)6 (152.4)24 (609.6)Service24 (609.6)Service24 (609.6)Service18 (457.2)WALLWALLWALLWALL
NOTE: NUMBERS IN () = mmCLEARANCESIMPORTANT: When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate ventillation to prevent re-circulation of discharge air. ST-A1225-01-0024 (609.6)24 recommended12 minimum Air Clearances
RA14 Series
11
FIGURE 2
CONTROL WIRING FOR GAS OR OIL FURNACE
FOR TYPICAL ELECTRIC HEATFOR TYPICAL GAS OR OIL HEAT
C
Y
G
W
R
W/BL
R
W/BK
G/BK
YL
BR
PU
YGW R
TYPICAL THERMOSTAT
SUBBASE
TYPICAL GAS OR
OIL FURNACE
TYPICAL CONDENSING
UNIT
BR – BROWN WIRE
YL – YELLOW WIRE
X – WIRE CONNECTION
BR –BROWN WIRE
R –RED WIRE
YL –YELLOW WIRE
W/BK –WHITE WIRE WITH BLACK STRIPE
G/BK –GREEN WIRE WITH BLACK STRIPE
PU –PURPLE WIRE (NOT USED)
X –WIRE CONNECTION
*IF MAXIMUM OUTLET TEMPERATURE RISE IS DESIRED, IT IS RECOMMENDED THAT
W1 (W/BK) AND W2 (W/BL) BE JUMPERED TOGETHER.
YL
BR
TYPICAL CONDENSING
UNIT
YL
BR
X
X
X
X X
X
X
X
X
YGW R
TYPICAL THERMOSTAT
SUBBASE
X
TYPICAL ELECTRIC HEAT
LOW VOLTAGE JUNCTION BOX
•*
Application Guidelines
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc.
2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).
3. Maximum outdoor operating air temperature is 125°F (51.7°C).
4. For reliable operation, unit should be level in all horizontal planes.
5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector
provided.
6. Do not apply capillary tube indoor coils to these units.
7. Factory – supplied filter drier must be installed.
Air Wiring Diagram/Application Guidelines
RA14 Series
12
Control Wiring
Air Refrigerant Line Size Information
RA14 Series
1313 - 16 SEER Single-Stage Air-ConditionersUnit SizeAllowableLiquid LineSizeAllowableSuction LineSizeApply Long Line Guidelines ifLinear Line Length ExceedsThose Shown Below (Feet)Equivalent Length (Feet)< 2526-5051-7576-100101-125126-150151-175176-200201-225226-250(-)A13(-)A14A/B(-)A14W(-)A16Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) * / Capacity Multiplier1.5 Ton**SEENOTE 3 1/4" 5/8"N/RN/RN/RN/R25 / 1.0050 / 0.9962 / 0.9843 / 0.9824 / 0.975 / 0.97N/RN/RN/RN/R5/16"5/8"N/R22319818825 / 1.0050 / 0.9975 / 0.9898 / 0.9893 / 0.9788 / 0.9783 / 0.9678 / 0.9673 / 0.9568 / 0.943/8"5/8"17814813212525 / 1.0050 / 0.9975 / 0.98100 / 0.98100 / 0.97100 / 0.97100 / 0.96100 / 0.96100 / 0.95100 / 0.941/4" 3/4"**N/RN/RN/RN/R25 / 1.0050 / 1.0062 / 0.9943 / 0.9924 / 0.995 / 0.99N/RN/RN/RN/R5/16"3/4"**N/R22319818825 / 1.0050 / 1.0075 / 0.9998 / 0.9993 / 0.9988 / 0.9983 / 0.9978 / 0.9873 / 0.9868 / 0.983/8"3/4"**17814813212525 / 1.0050 / 1.0075 / 1.00100 / 0.99100 / 0.99100 / 0.99100 / 0.99100 / 0.98100 / 0.98100 / 0.982 Ton1/4" 5/8"N/RN/RN/RN/R25 / 0.9950 / 0.9821 / 0.97N/RN/RN/RN/RN/RN/RN/R5/16"5/8"24319317517525 / 0.9950 / 0.9875 / 0.9787 / 0.9677 / 0.9569 / 0.9461 / 0.9353 / 0.9245 / 0.9137 / 0.903/8"5/8"16212811711725 / 0.9950 / 0.9875 / 0.97100 / 0.96100 / 0.95100 / 0.9498 / 0.9395 / 0.9292 / 0.9189 / 0.901/4" 3/4"N/RN/RN/RN/R25 /1.0050 / 1.0021 / 0.99N/RN/RN/RN/RN/RN/RN/R5/16"3/4"24319317517525 /1.0050 / 1.0075 / 0.9987 / 0.9977 / 0.9869 / 0.9861 / 0.9853 / 0.9745 / 0.9737 / 0.963/8"3/4"16212811711725 / 1.0050 / 1.0075 / 0.99100 / 0.99100 / 0.98100 / 0.9898 / 0.9895 / 0.9793 / 0.9790 / 0.962.5 Ton5/16"5/8"N/RN/R11011025 / 0.9950 / 0.9875 / 0.9670 / 0.9459 / 0.9348 / 0.9136 / 0.90N/RN/RN/R3/8"5/8"142117737325 / 0.9950 / 0.9875 / 0.96100 / 0.9498 / 0.9394 / 0.9190 / 0.90N/RN/RN/R5/16"3/4"21317511011025 / 1.0050 / 0.9975 / 0.9970 / 0.9859 / 0.9848 / 0.9736 / 0.9625 / 0.9613 / 0.95N/R3/8"3/4"142117737325 / 1.0050 / 0.9975 / 0.99100 / 0.9898 / 0.9894 / 0.9790 / 0.9686 / 0.9682 / 0.9578 / 0.953 Ton5/16"5/8"N/RN/RN/RN/R25 / 0.9950 / 0.9766 / 0.9449 / 0.9232 / 0.90N/RN/RN/RN/RN/R3/8"5/8"10885908225 / 0.9950 / 0.9775 / 0.9495 / 0.9289 / 0.90N/RN/RN/RN/RN/R5/16"3/4"N/R12813512325 / 1.0050 / 0.9966 / 0.9849 / 0.9832 / 0.9715 / 0.96N/RN/RN/RN/R3/8"3/4"10885908225 / 1.0050 / 0.9975 / 0.9895 / 0.9889 / 0.9784 / 0.9678 / 0.9572 / 0.9467 / 0.9361 / 0.931/2"3/4"5443454125 / 1.0050 / 0.9975 / 0.98100 / 0.98100 / 0.97100 / 0.96100 / 0.95100 / 0.94100 / 0.93100 / 0.935/16"7/8"N/R12813512325 / 1.0050 / 1.0066 / 1.0049 / 0.9932 / 0.9915 / 0.99N/RN/RN/RN/R3/8"7/8"10885908225 / 1.0050 / 1.0075 / 1.0095 / 0.9989 / 0.9984 / 0.9978 / 0.9872 / 0.9867 / 0.9861 / 0.971/2"7/8"5443454125 / 1.0050 / 1.0075 / 1.00100 / 0.99100 / 0.99100 / 0.99100 / 0.98100 / 0.98100 / 0.98100 / 0.973.5 Ton3/8"3/4"150102757525 / 0.9950 / 0.9875 / 0.9788 / 0.9680 / 0.9572 / 0.9465 / 0.9257 / 0.9149 / 0.90N/R1/2"3/4"7551383825 / 0.9950 / 0.9875 / 0.97100 / 0.96100 / 0.95100 / 0.94100 / 0.92100 / 0.91100 / 0.90N/R3/8"7/8"150102757525 / 1.0050 / 1.0075 / 0.9988 / 0.9980 / 0.9972 / 0.9865 / 0.9757 / 0.9749 / 0.9642 / 0.961/2"7/8"7551383825 / 1.0050 / 1.0075 / 0.99100 / 0.99100 / 0.99100 / 0.98100 / 0.97100 / 0.97100 / 0.96100 / 0.96NOTES: 1.Do not exceed 200 ft linear line length.2.*Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.3. **3/4" suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.4.Always use the smallest liquid line allowable to minimize refrigerant charge.5.Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 6.Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. NOTE: Values based on 105°F liquid temperature and 45°F evaporator temperature in cooling mode depending on sizeRefrigerant Line Size Information
Air Refrigerant Line Size Information
RA14 Series
1413 - 16 SEER Single-Stage Air-ConditionersUnit SizeAllowableLiquid LineSizeAllowableSuction LineSizeApply Long Line Guidelines ifLinear Line Length ExceedsThose Shown Below (Feet)Equivalent Length (Feet)< 2526-5051-7576-100101-125126-150151-175176-200201-225226-250(-)A13(-)A14A/B(-)A14W(-)A16Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) * / Capacity Multiplier4 Ton3/8"3/4"148110N/R35 25 / 0.99 50 / 0.9875 / 0.9677 / 0.9567 / 0.9357 / 0.9246 / 0.91N/RN/RN/R1/2"3/4"7455N/R18 25 / 0.99 50 / 0.9875 / 0.96100 / 0.95100 / 0.93100 / 0.92100 / 0.91N/RN/RN/R3/8"7/8"148110N/R35 25 / 1.00 50 / 0.99 75 / 0.99 77 / 0.98 67 / 0.97 57 / 0.9746 / 0.9636 / 0.9626 / 0.9515 / 0.951/2"7/8"7455N/R18 25 / 1.00 50 / 0.99 75 / 0.99 100 / 0.98 100 / 0.97 100 / 0.97100 / 0.96100 / 0.9699 / 0.9597 / 0.955 Ton3/8"3/4"780N/R0 25 / 0.99 50 / 0.9775 / 0.9461 / 0.9246 / 0.90N/RN/RN/RN/RN/R1/2"3/4"390N/R0 25 / 0.99 50 / 0.9775 / 0.94100 / 0.92100 / 0.90N/RN/RN/RN/RN/R3/8"7/8"780N/R0 25 / 1.00 50 / 0.99 75 / 0.98 61 / 0.9746 / 0.9632 / 0.9518 / 0.94N/RN/RN/R1/2"7/8"390N/R0 25 / 1.00 50 / 0.99 75 / 0.98 100 / 0.97100 /0.96100 / 0.9597 / 0.9495 / 0.9492 / 0.9389 / 0.923/8"1-1/8"780N/R0 25 / 1.01 50 / 1.01 75 / 1.00 61 / 1.00 46 / 0.99 32 / 0.99 18 / 0.99N/RN/RN/R1/2"1-1/8"390N/R0 25 / 1.01 50 / 1.01 75 / 1.00 100 /1.00 100 / 0.99 100 / 0.99 97 / 0.99 95 / 0.99 92 / 0.99 89 / 0.98Refrigerant Line Size Information (con’t.)NOTES: 1.Do not exceed 200 ft linear line length.2.*Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.3. **3/4" suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.4.Always use the smallest liquid line allowable to minimize refrigerant charge.5.Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 6.Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. NOTE: Values based on 105°F liquid temperature and 45°F evaporator temperature in cooling mode depending on size
1513 - 16 SEER Single-Stage Air-ConditionersUnit SizeAllowableLiquid LineSizemm [in.]AllowableSuction LineSizemm [in.]Apply Long Line Guidelines ifLinear Line Length ExceedsThose Shown Below (Feet)Equivalent Length (Meters)< 88-1516-2324-3031-3839-4647-5354-6162-6970-76(-)A13(-)A14A/B(-)A14W(-)A16Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) * / Capacity Multiplier5.3 KW[1.5 Ton]**SEENOTE 3 6.35 [1/4]15.88 [5/8]N/RN/RN/RN/R8 / 1.00 15 / 0.99 19 / 0.98 13 / 0.98 7 / 0.97 2 / 0.97N/RN/RN/RN/R7.94 [5/16]15.88 [5/8]N/R686057 8 / 1.00 15 / 0.99 23 / 0.98 30 / 0.98 28 / 0.97 27 / 0.9725 / 0.9624 / 0.9622 / 0.9521 / 0.949.53 [3/8]15.88 [5/8]54454038 8 / 1.00 15 / 0.99 23 / 0.98 30 / 0.98 30 / 0.97 30 / 0.9730 / 0.9630 / 0.9630 / 0.9530 / 0.946.35 [1/4]**19.05 [3/4]**N/RN/RN/RN/R8 / 1.00 15 / 1.00 19 / 0.99 13 / 0.99 7 / 0.99 2 / 0.99N/RN/RN/RN/R7.94 [5/16]**19.05 [3/4]**N/R686057 8 / 1.00 15 / 1.00 23 / 0.99 30 / 0.99 28 / 0.99 27 / 0.99 25 / 0.99 24 / 0.98 22 / 0.98 21 / 0.989.53 [3/8]**19.05 [3/4]**54454038 8 / 1.00 15 / 1.00 23 / 0.99 30 / 0.99 30 / 0.99 30 / 0.99 30 / 0.99 30 / 0.98 30 / 0.98 30 / 0.987.0 KW[2 Ton]6.35 [1/4]15.88 [5/8]N/RN/RN/RN/R8 / 0.99 15 / 0.98 6 / 0.97N/RN/RN/RN/RN/RN/RN/R7.94 [5/16]15.88 [5/8]74595353 8 / 0.99 15 / 0.98 23 / 0.9727 / 0.9623 / 0.9521 / 0.9419 / 0.9316 / 0.9214 / 0.9111 / 0.909.53 [3/8]15.88 [5/8]49393636 8 / 0.99 15 / 0.98 23 / 0.9730 / 0.9630 / 0.9530 / 0.9430 / 0.9329 / 0.9228 / 0.9127 / 0.906.35 [1/4]19.05 [3/4]N/RN/RN/RN/R8 / 1.00 15 / 1.00 6 / 0.99N/RN/RN/RN/RN/RN/RN/R7.94 [5/16]19.05 [3/4]74595353 8 / 1.00 15 / 1.00 23 / 0.99 27 / 0.99 23 / 0.98 21 / 0.98 19 / 0.98 16 / 0.97 14 / 0.9711 / 0.969.53 [3/8]19.05 [3/4]49393636 8 / 1.00 15 / 1.00 23 / 0.99 30 / 0.99 30 / 0.98 30 / 0.98 30 / 0.98 29 / 0.97 28 / 0.9727 / 0.968.8 KW[2.5 Ton]7.94 [5/16]15.88 [5/8]N/RN/R3434 8 / 0.99 15 / 0.9823 / 0.9621 / 0.9418 / 0.9315 / 0.9111 / 0.90N/RN/RN/R9.53 [3/8]15.88 [5/8]43362222 8 / 0.99 15 / 0.9823 / 0.9630 / 0.9430 / 0.9329 / 0.9127 / 0.90N/RN/RN/R7.94 [5/16]19.05 [3/4]65533434 8 / 1.00 15 / 0.99 23 / 0.99 21 / 0.98 18 / 0.98 15 / 0.9711 / 0.968 / 0.964 / 0.95N/R9.53 [3/8]19.05 [3/4]43362222 8 / 1.00 15 / 0.99 23 / 0.99 30 / 0.98 30 / 0.98 29 / 0.9727 / 0.9626 / 0.9625 / 0.9524 / 0.9510.6 KW[3 Ton]7.94 [5/16]15.88 [5/8]N/RN/RN/RN/R8 / 0.99 15 / 0.9720 / 0.9415 / 0.9210 / 0.90N/RN/RN/RN/RN/R9.53 [3/8]15.88 [5/8]33262725 8 / 0.99 15 / 0.9723 / 0.9429 / 0.9227 / 0.90N/RN/RN/RN/RN/R7.94 [5/16]19.05 [3/4]N/R394137 8 / 1.00 15 / 0.99 20 / 0.98 15 / 0.98 10 / 0.975 / 0.96N/RN/RN/RN/R9.53 [3/8]19.05 [3/4]33262725 8 / 1.00 15 / 0.99 23 / 0.98 29 / 0.98 27 / 0.9726 / 0.9624 / 0.9522 / 0.9420 / 0.9319 / 0.9312.70 [1/2]19.05 [3/4]17131412 8 / 1.00 15 / 0.99 23 / 0.98 30 / 0.98 30 / 0.9730 / 0.9630 / 0.9530 / 0.9430 / 0.9330 / 0.937.94 [5/16]22.23 [7/8]N/R394137 8 / 1.00 15 / 1.00 20 / 1.00 15 / 0.99 10 / 0.99 5 / 0.99N/RN/RN/RN/R9.53 [3/8]22.23 [7/8]33262725 8 / 1.00 15 / 1.00 23 / 1.00 29 / 0.99 27 / 0.99 26 / 0.99 24 / 0.98 22 / 0.98 20 / 0.98 19 / 0.9712.70 [1/2]22.23 [7/8]17131412 8 / 1.00 15 / 1.00 23 / 1.00 30 / 0.99 30 / 0.99 30 / 0.99 30 / 0.98 30 / 0.98 30 / 0.98 30 / 0.9712.3 KW[3.5 Ton]9.53 [3/8]19.05 [3/4]46312323 8 / 0.99 15 / 0.98 23 / 0.9727 / 0.9624 / 0.9522 / 0.9420 / 0.9217 / 0.9115 / 0.90N/R12.70 [1/2]19.05 [3/4]23151111 8 / 0.99 15 / 0.98 23 / 0.9730 / 0.9630 / 0.9530 / 0.9430 / 0.9230 / 0.9130 / 0.90N/R9.53 [3/8]22.23 [7/8]46312323 8 / 1.00 15 / 1.00 23 / 0.99 27 / 0.99 24 / 0.99 22 / 0.98 20 / 0.97 17 / 0.9715 / 0.9613 / 0.9612.70 [1/2]22.23 [7/8]23151111 8 / 1.00 15 / 1.00 23 / 0.99 30 / 0.99 30 / 0.99 30 / 0.98 30 / 0.97 30 / 0.9730 / 0.9630 / 0.96NOTES: 1.Do not exceed 61 meters linear line length.2.*Do not exceed 30 meters vertical separation if outdoor unit is above indoor unit.3. **19.05 mm [3/4 in.] suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.4.Always use the smallest liquid line allowable to minimize refrigerant charge.5.Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 6.Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. [ ] Designates Metric Conversions Air Refrigerant Line Size Information
RA14 Series
Refrigerant Line Size Information (con’t.)
Air Refrigerant Line Size Information
RA14 Series
16Refrigerant Line Size Information (con’t.)NOTES: 1.Do not exceed 61 meters linear line length.2.*Do not exceed 30 meters vertical separation if outdoor unit is above indoor unit.3. **19.05 mm [3/4 in.] suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.4.Always use the smallest liquid line allowable to minimize refrigerant charge.5.Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 6.Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. [ ] Designates Metric Conversions13 - 16 SEER Single-Stage Air-ConditionersUnit SizeAllowableLiquid LineSizeAllowableSuction LineSizeApply Long Line Guidelines ifLinear Line Length ExceedsThose Shown Below (Feet)Equivalent Length (Meters)< 88-1516-2324-3031-3839-4647-5354-6162-6970-76(-)A13(-)A14A/B(-)A14W(-)A16Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) * / Capacity Multiplier14.1 KW[4 Ton]9.53 [3/8]19.05 [3/4]4534N/R11 8 / 0.99 15 / 0.9823 / 0.9624 / 0.9520 / 0.9317 / 0.9214 / 0.91NRNRNR12.7 [1/2]19.05 [3/4]2317N/R5 8 / 0.99 15 / 0.9823 / 0.9630 / 0.9530 / 0.9330 / 0.9230 / 0.91NRNRNR9.53 [3/8]22.23 [7/8]4534N/R11 8 / 1.00 15 / 0.99 23 / 0.99 24 / 0.98 20 / 0.97 17 / 0.9714 / 0.9611 / 0.968 / 0.955 / 0.9512.7 [1/2]22.23 [7/8]2317N/R5 8 / 1.00 15 / 0.99 23 / 0.99 30 / 0.98 30 / 0.97 30 / 0.9730 / 0.9630 / 0.9630 / 0.9530 / 0.9517.6 KW[5 Ton]9.53 [3/8]19.05 [3/4]2417N/R0 8 / 0.99 15 / 0.9723 / 0.9419 / 0.9214 / 0.90NRNRNRNRNR12.7 [1/2]19.05 [3/4]128N/R0 8 / 0.99 15 / 0.9723 / 0.9430 / 0.9230 / 0.90NRNRNRNRNR9.53 [3/8]22.23 [7/8]2417N/R0 8 / 1.00 15 / 0.99 23 / 0.98 19 / 0.9714 / 0.9610 / 0.955 / 0.94NRNRNR12.7 [1/2]22.23 [7/8]128N/R0 8 / 1.00 15 / 0.99 23 / 0.98 30 / 0.9730 /0.9630 / 0.9530 / 0.9429 / 0.9428 / 0.9327 / 0.929.53 [3/8]28.58 [1-1/8]2417N/R0 8 / 1.01 15 / 1.01 23 / 1.00 19 / 1.00 14 / 0.99 10 / 0.99 5 / 0.99NRNRNR12.7 [1/2]28.58 [1-1/8]128N/R0 8 / 1.01 15 / 1.01 23 / 1.00 30 / 1.00 30 / 0.99 30 / 0.99 30 / 0.99 29 / 0.99 28 / 0.99 27 / 0.98
17
Air Performance Data
RA14 Series
Tested Combination
Outdoor
Unit Indoor Coil Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]SEER EER Indoor CFM
[L/s]
RA1418AJ1 RCF2417STA+RXMD-C04 17800 [5.2]12100 [3.5] 5700 [1.7]14.00 11.50 600 [283.2]
RA1424BJ1 RCF2417STA+RXMD-C04 23200 [6.8]17500 [5.2] 5700 [1.7]14.00 11.50 800 [376.0]
RA1430AJ1 RCF3617STA+RXMD-C04 28800 [8.4]19500 [5.7] 9300 [2.7]14.00 11.50 1000 [471.9]
RA1436AJ1 RCF3617STA+RXMD-C04 34200 [10.0]23200 [6.8]11000 [3.2]14.00 11.50 1050 [495.5]
RA1436AC1 RCF3617STA+RXMD-C04 34200 [10.0]23200 [6.8]11000 [3.2]14.00 11.50 1050 [495.5]
RA1436AD1 RCF3617STA+RXMD-C04 34200 [10.0]23200 [6.8]11000 [3.2]14.00 11.50 1050 [495.5]
RA1442CJ1 RCF4821STA+RXMD-C04 39500 [11.6]28900 [8.5]10600 [3.1]14.00 11.50 1350 [634.5]
RA1442CC1 RCF4821STA+RXMD-C04 39500 [11.6]28900 [8.5]10600 [3.1]14.00 11.50 1350 [634.5]
RA1448AJ1 RCF4821STA+RXMD-C04 46000 [13.5]31200 [9.1]14800 [4.3]14.00 11.70 1450 [684.3]
RA1448AC1 RCF4821STA+RXMD-C04 46000 [13.5]31200 [9.1]14800 [4.3]14.00 11.70 1450 [684.3]
RA1448AD1 RCF4821STA+RXMD-C04 46000 [13.5]31200 [9.1]14800 [4.3]14.00 11.70 1450 [684.3]
RA1460BJ1 RCF6024STA+RXMD-C04 55500 [16.3]38100 [11.2]17400 [5.1]14.00 11.70 1525 [716.8]
RA1460AD1 RCF6024STA+RXMD-C04 55500 [16.3]38100 [11.2]17400 [5.1]14.00 11.70 1525 [716.8]
RA1460BC1 RCF6024STA+RXMD-C04 55500 [16.3]38100 [11.2]17400 [5.1]14.00 11.70 1525 [716.8]
Note: Additional ratings and system match ups can be accessed on MyRheem.com at: https://my.rheem.com/static/private/ahriresidential.html
Additional ratings and system match ups and downloadable ratings certificates can be accessed from the AHRI website: www.ahridirectory.org
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions – Cooling
Air Guide Specifications
RA14 Series
18
GUIDE SPECIFICATIONS
General
System Description
Outdoor-mounted, air-cooled, split-system air conditioner com-
posite base pan unit suitable for ground or rooftop installation.
Unit consists of a hermetic compressor, an air-cooled coil, pro-
peller-type condenser fan, suction and legend line service valve,
and a control box. Unit will discharge supply air upward as shown
on contract drawings. Unit will be used in a refrigeration circuit to
match up to a coil unit.
Quality Assurance
— Unit will be rated in accordance with the latest edition of AHRI
Standard 210.
— Unit will be certified for capacity and efficiency, and listed in
the latest AHRI directory.
— Unit construction will comply with latest edition of ANSI/
ASHRAE and with NEC.
— Unit will be constructed in accordance with UL standards and
will carry the UL label of approval. Unit will have c-UL-us
approval.
— Unit cabinet will be capable of withstanding ASTM B117 1000-
hr salt spray test.
— Air-cooled condenser coils will be leak tested at 150 psig and
pressure tested at 550 psig.
— Unit constructed in ISO9001 approved facility.
Delivery, Storage, and Handling
— Unit will be shipped as single package only and is stored and
handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer) — U.S. and
Canada only.
Products
Equipment
Factory assembled, single piece, air-cooled air conditioner unit.
Contained within the unit enclosure is all factory wiring, piping,
controls, compressor, refrigerant charge R-410A, and special fea-
tures required prior to field start-up.
Unit Cabinet
— Unit cabinet will be constructed of galvanized steel, bonder-
ized, and coated with a powder coat paint.
— All units constructed with louver coil protection and corner post.
Louver can be removed by removing one fastener per louver
panel.
AIR-COOLED, SPLIT-SYSTEM AIR CONDITIONER
RA14
1-1/2 TO 5 NOMINAL TONS
Fans
— Condenser fan will be direct-drive propeller type, discharging
air upward.
— Condenser fan motors will be totally enclosed, 1-phase type
with class B insulation and permanently lubricated bearings.
Shafts will be corrosion resistant.
— Fan blades will be statically and dynamically balanced.
— Condenser fan openings will be equipped with coated steel
wire safety guards.
Compressor
— Compressor will be hermetically sealed.
— Compressor will be mounted on rubber vibration isolators.
Condenser Coil
— Condenser coil will be air cooled.
— Coil will be constructed of aluminum fins mechanically bonded
to copper tubes.
Refrigeration Components
— Refrigeration circuit components will include liquid-line shutoff
valve with sweat connections, vapor-line shutoff valve with
sweat connections, system charge of R-410A refrigerant, and
compressor oil.
— Unit will be equipped with filter drier for R-410A refrigerant for
field installation.
Operating Characteristics
— The capacity of the unit will meet or exceed _____ Btuh at a
suction temperature of _____ °F/°C. The power consumption
at full load will not exceed _____ kW.
— Combination of the unit and the evaporator or fan coil unit will
have a total net cooling capacity of _____ Btuh or greater at
conditions of _____ CFM entering air temperature at the evap-
orator at _____ °F/°C wet bulb and _____ °F/°C dry bulb, and
air entering the unit at _____ °F/°C.
— The system will have a SEER of _____ Btuh/watt or greater at
DOE conditions.
Electrical Requirements
— Nominal unit electrical characteristics will be _____ v, single
phase, 60 hz. The unit will be capable of satisfactory operation
within voltage limits of _____ v to _____ v.
— Nominal unit electrical characteristics will be _____ v, three
phase, 60 hz. The unit will be capable of satisfactory operation
within voltage limits of _____ v to _____ v.
— Unit electrical power will be single point connection.
— Control circuit will be 24v.
Special Features
— Refer to section of this literature identifying accessories and
descriptions for specific features and available enhancements.
19
Air Limited Warranty
RA14 Series
GENERAL TERMS OF LIMITED WARRANT Y*
Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited
warranty.
*For complete details of the Limited and Conditional Warranties, including
applicable terms and conditions, contact your local contractor or the
Manufacturer for a copy of the product warranty certificate.
Conditional Parts
(Registration Required)...............................Ten (10) Years
The new degree of comfort.™
Rheem Heating, Cooling & Water Heating • 5600 Old Greenwood Road
Fort Smith, Arkansas 72908 • www.rheem.com
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
PRINTED IN U.S.A. 6/19 QG FORM NO. A11-220 REV. 9
Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Brampton, Ontario • L6Y 0P5