HomeMy WebLinkAboutTROP STL MFG SPECNNEMOjetc.
TABLE DECK APPLICATION TYPE DESCRIPTION PAr;c
1�
1D
W000
Wood
New, Reroof(t ear-Utt), Recover
New, Reroof(Tear-Off), Recover
C-2
D-1
Mechanically Attached Insulation, Plate -Bonded Roof Cover
Insulated, Mechanically Attached Roof Cover
8
9
IE
Wood
New, Reroof (Tear -Off), Recover
D-3
Non -Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover
9
1F
Wood
New, Reroof (Tear -Off), Recover
E-1
Non -Insulated, Mechanically Attached Roof Cover
10
1G
Wood
New, Reroof (Tear -Off), Recover
E-2
Non -Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover
10
IH
Wood
New, Reroof (Tear -Off/, Recover
G
Optional Insulation, Loose -Laid Roof Cover, Pressure Equalizing Vent
10
2A
Steel
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
11-12
26
Steel or structural concrete
New, Reroof (Tear -Off), Recover
B-1
Mach. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
13-20
2C
Steel or structural concrete
New, Reroof (Tear -Off), Recover
B-1
Mach. Attached Base Insulation, Bonded Top Insulation, Bonded Base Ply, Bonded Roof Cover
21-22
21)
Steel
New, Reroof (Tear -Off), Recover
B-2
Mech. Attached Thermal Barrier, Bonded Vapor Barrier, Bonded Insulation, Bonded Roof Cover
23-24
2E
Steel or structural concrete
New, Reroof (Tear -Off), Recover
C-1
Mechanically Attached Insulation, Bonded Roof Cover
25-33
2F
Steel or structural concrete
New, Reroof (Tear -Off), Recover
C-1
Mechanically Attached Insulation, Bonded Base Ply, Bonded Roof Cover
33
2G
Steel
New, Reroof (Tear -Off), Recover
C-2
Mechanically Attached Insulation, Plate -Bonded Roof Cover
34-36
2H
Steel or structural concrete
New, Reroof (Tear -Off), Recover
D-1
Insulated, Mechanically Attached Roof Cover (Stress Plates)
3642
21
Steel or structu ral concrete
New, Reroof (Tear -Off), Recover
D-2
Insulated, Mechanically Attached Roof Cover (RUSS Strips)
43
3A
Structural concrete,
New, Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
44-56
3B
Structural concrete
New, Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Base Ply, Bonded Roof Cover
57
3C
Structural concrete
New, Reroof (Tear -Oft), Recover
C-2
Mechanically Attached Insulation, Plate -Bonded Roof Cover
58-59
3D
Structural cpncrete .
New, Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
60
3E
Structural concrete
New, Reroof (Tear -Off), Recover
G
Optional Insulation, Loose -Laid Roof Cover, Pressure Equalizing Vent
60
4A
Lightweight concrete
New, Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
61-63
4B
Lightweight concrete
New, Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
64
4C
Lightweight concrete / steel
New, Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
64-67
41)
Lightweight concrete/concrete
New, Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
68-69
SA
Cementitious wood fiber
New, Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
70-71
5B
Cementitious wood fiber
New, Reroof (Tear -Off), Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
71
6A
Existing gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
72-73
6B
Existing gypsum
Reroof(Tear-Off)
F
Non -Insulated, Bonded Roof Cover
73
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
74-78
7B
Various
Recover
A-1
Bonded Insulation, Bonded Base Ply, Bonded Roof Cover
79-80
7C
Steel
Recover
C-2
Mechanically Attached Insulation, Plate -Bonded Roof Cover
81
71)
Steel
Recover
D-1
Insulated, Mechanically Attached Roof Cover
82
7E
Steel
Recover
D-2
Insulated, Mechanically Attached Roof Cover(RUSS Strips)
83
7F
Various
Recover
E-1
Non -Insulated, Mechanically Attached Roof Cover
84
7G
Various
Recover
F-1
Non -Insulated, Bonded Roof Cover
85
7H
Various
Recover
F-2
New LWC over Existing Roof, Bonded Roof Cover
86
8A/8B
Guidance/ Limitations for use of Hilti
fasteners in Type Bsteel decksecurement
beneath Carlisle SynTec roofsystems
87
NEMO ETC, LLC Evaluation Report 033680.09.10-R24 for FL14083-1124
Certificate of Authorization #32455 6' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 24:06/08/2020
©2019, NEMO ETC, LLC Carlisle Sure -Weld TPO Single Pty Roof Systems; (717) 245-7264 Appendix 1, Page 1 of 87
ONEMOjetc.
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
D As -tested roof cover performance in accordance with FM 4474 and TAS 114, Appendix J indicates min. 22 ga., Type B, Grade 40 steel deck at max. 6 ft spans attached with 5/8 -inch diameter puddle welds spaced
6" o.c., with deck side laps secured max. 24" o.c. w/ fi"-14x1" long self -tapping hex -head screws, maybe used for roof assemblies over steel deck up to a maximum design pressure of -60.0 psf. This does not
preclude Note 1 above.
➢ Tables 8A and 8B provide guidance / limitations associated with use of fasteners from HIM, Inc. to secure steel decking to structural members.
2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:
➢ Wood Deck: Sure -Seal HP Fastener with Sure -Seal Insulation Plate (aka, Carlisle's Insulation Fastening Plate). Minimum 1 -inch wood penetration.
➢ Steel Deck: Sure -Seal HP Fastener with Sure -Seal Insulation Plate (aka, Carlisle's Insulation Fastening Plate). Minimum %-inch steel penetration, engage the top flute of the steel deck.
Concrete Deck: Sure -Seal HD 14-10 Concrete Fastener, Carlisle CD -10 or HP Concrete Spike (1/4) with Sure -Seal Insulation Plate (aka, Carlisle's Insulation Fastening Plate). Minimum 1 -inch embedment.
Fasteners installed with a pilot hole in accordance with the fastener manufacturers published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, fiberboard, perlite and/or gypsum -based insulation board that meets the QA requirements of F.A.C. Rule
61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof rover.
4. Minimum 200 psi, minimum 2 -inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type C-2 (plate bonded roof cover) or Type D (mechanically attached membrane),
whereby the membrane fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and concrete
deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through
proper codified and/or FBC Approval documentation.
5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016) using fasteners & plates from Note 2. Carlisle INSUL-
FAST Fastener may be used in place of Sure -Seal HP Fastener for preliminary attachment purposes over wood and steel deck.
6. Unless otherwise noted, insdlation adhesive application rates areas follows. RIBBON or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturers published instructions:
D Hot asphalt: FULL -coverage at 25 lbs/square.
➢ FAST 100LV (FULL):., FULL -coverage at 1 gal./square.
➢ FAST 100LV (RIBBON): Continuous ribbons, max. 6 -inch o.c.
➢ FAST Dual -Tank (FAST DT) (FULL): Continuous ribbons, max. 4 -inch o.c.
➢ FAST Dual -Tank (FAST DT) (RIBBON): Continuous ribbons, max. 12 -inch o.c. Note: When installing multiple layers of insulation, FAST Dual -Tank beads shall be placed perpendicular to those
placed for attachment of the previous layer
D Flexible FAST (FULL): Continuous ribbons, max. 4 -inch o.c. or spray -applied at 1 gal./square.
➢ Flexible FAST (RIBBON): Continuous ribbons, max. 12 -inch o.c.
➢ Flexible FAST Dual -Tank (Flexible FAST DT) (FULL): Continuous ribbons, max. 4 -inch o.c. or spray -applied at 1 gal./square.
➢ Flexible FAST Dual -Tank (Flexible FAST DT) (RIBBON): Continuous ribbons, max. 12 -inch o.c.
➢ OlyBond 500 (OB500): Continuous ribbons, max. 12 -inch o.c. using PaceCart, SpotShot or Canisters. Note: OlyBond 500 Green may be used where OlyBond 500 is referenced.
D Note: FULL applications may be used where RIBBON applications are referenced.
➢ Note: When multiple layers(s) of insulation and/ar coverboard are installed in ribbon -applied adhesive, boards shall be staggered from layer -to -layer.
➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to'increase'the MDP listings in the tables; rather If MDP listing below meets or exceeds that listed for a particular system in the tables, then the
thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table:
FAST 100LV or Flexible FAST: MDP -157.5 psf (Min. 0.5 -inch thick)
➢ OlyBond 500(OB500): MDP-187.Spsf (Min. 0.5 -inch thick)
8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
NEMO ETC, LLC Evaluation Report 033680.09.10-R24 for FL14083-RZ4
Certificate of Authorization #32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION Revision 24: 06/08/2020
©2019, NEMO ETC, LLC Carlisle Sure -Weld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 2 of 87
ONEMOletc.
9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss Prevention
Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data
Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
10. For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no
rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. Aqualified design professional shall review the data for comparison to the minimum
requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates in a bonded recover or re-roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For System Type D, steel deck applications, the roof membrane shall be run with its length perpendicular to the steel deck flutes.
14. For Structural Concrete Deck or Recover Applications using System Type C-2 (Plate Bonded Roof Cover) or Type D (Mechanically Attached Roof Cover), the insulation is optional. Alternatively, min. 0.25 -inch to 0.625 -
inch DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass -Mat Roof Board, min. 3/8 -inch Insulfoam R -Tech EPS or Fan -Fold or min. 0.5 -inch ECOSTORM VHS, HP Recovery Board, H -
Shield HD, InsulBase, InsulBase HD or SecurShield HD maybe used as a separator board, preliminarily attached prior to roof cover installation. The separator component shall be documented as meeting FBC 1505.1
and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications.
15. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2 -inches.
For LWC over structural concrete,, reference is made to FBC Section 1917.4.1, Point 1. For "pre-existent" LWC references, listings were established through testing over lightweight concrete cast using only foaming
agent (ASTM C896), water and Pgrtland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami -Dade BCCO (FBC CER1592). Unless otherwise noted, use of these listings
in new construction or re-robf (tear -off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction.
16. For adhered membrane systems, side laps shall be minimum 2 -inch wide sealed with min. 1.5 -inch heat weld. Unless otherwise noted, membrane adhesive application rates are asfollows
MEMBRANE
ADHESIVE
METHOD
RATE
Sure -Weld or Sure -Weld HS
Sure -Weld Bonding Adhesive
Contact (both sides)
60 ft�/gal
Sure -Weld or Sure -Weld HS
Aqua Base 120 Bonding Adhesive (Aqua Base 120)
Contact (both sides)
120 ft2/gal
Sure -Weld or Sure -Weld HS
Low VOC Bonding Adhesive (LVOC BA)
Contact (both sides)
60 ft2/gal
Sure -Weld or Sure -Weld HS
Sure -Seal 90-8-30A Bonding Adhesive
Contact (both sides)
60 ft'/gal
Sure -Weld
CAV -GRIP III Adhesive/Primer (CAV -GRIP III AP)
Contact (both sides)
110 ft2/gal
Sure -Weld FleeceBACK
Aqua Base 120 Bonding Adhesive
Wet lay (substrate)
120 ft2/gal
Sure -Weld FleeceBACK
HydroBond Water -Based Adhesive (HydroBond WB)
Wet lay (substrate)
100 to 133 ft'/gal
Sure -Weld FleeceBACK
FAST 100LV, FAST Dual-TankIa Flexible FAST
DT , FAST
( )
Wet y (substrate)
RIBBON spaced as noted herein or
FULL Coverage =1 gal/square or continuous ribbons, maximum 4 -inch o.c.
Sure -Weld FleeceBACK
Flexible FAST Dual -Tank (Flexible FAST DT)
Wet lay (substrate)
RIBBON spaced as noted herein or
FULL Coverage =1 gal/square, continuous ribbons, maximum 4 -inch o.c. or
spatter -applied at 3.5-4.0 lbs/square
Sure -Weld AFX
Carlisle Cold Applied Adhesive (C -CAA)
Wet lay (substrate)
1.5 gal/square
Sure -Weld AFX
Hot asphalt
Wet lay (substrate)
2516s/square
Sure -Weld FleeceBACK* RL-
VELCRO% Brand Securable Solutions
Only for use over InsulBase RL or SecurShield HD RL substrates. Roof cover is broomed into place and
rolled with 150 lb roller to establish contact.
17. For adhered membrane systems, unless otherwise noted:
NEMO ETC, LLC Evaluation Report C33680.09.10 -R24 for FL14083-R24
Certificate of Authorization #32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 24: 06/08/2020
©2019, NEMO ETC, LLC Carlisle Sure -Weld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 3 of 87
ON EMo I etc.
➢ Reference to "Sure -Weld" membrane below also includes "Sure -Weld EXTRA" and "Sure -Weld HS";
➢ Reference to "Sure -Weld FleeceBACK" Includes 100, 115 and 135;
➢ Reference to "Sure -Weld AFX" includes AFX 120, AFX 135 and AFX 155
18. Vapor barrier options for use over structural concrete deck followed by adhesive -applied insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in
Table 3A or 3B aoolies.
Option #
H -Shield b
VAPOR BARRIER OPTIONS; STRUcTURAL
Primer
CONCRETE DLCK; FOLLOWEDRY ADHESIVE-APPUEI)
Vapor Barrier
Type
INSULATION
Application
PER TABLE 3A OR 38:
Insulation Adhesive
MDP (psf)
VB -1.
702 Primer,
702 LV Primer, CAV -GRIP Primer or CAWGRIP III AP
VapAir Sea[ 725TR
Self -adhering
Flexible FAST (RIBBONS, 12 -inch o.c.)
-157.5
VB -2.
702 Primer,
702 LV Primer, CAV -GRIP Primer or CAV -GRIP III AP
VapAir Sea[ 725TR
Self -adhering
Flexible FAST DT (RIBBONS, 12 -inch o.c.)
-172.5
VB -3.
702 Primer,
702 LV Primer, CAV -GRIP Primer or CAV -GRIP III AP
VapAir Seal 725TR
Self -adhering
Flexible FAST or Flexible FAST DT (RIBBONS, 6 -inch o.c.)
-270.0
VB -4.
CAV -GRIP Primer or CAV -GRIP III AP
VapAir Seal 725TR
Self -adhering
Flexible FAST (FULL COVERAGE, l gal/square)
-427.5
VB -5.
ASTM D41
SureMB 90 Base
Hot -asphalt
Hot asphalt at 25 lbs/square
-172.5
VB -6.
ASTM D41SUreM89DTG
Base or SureMB 120TG Base
Torch -applied
Hot asphalt at25 lbs/square
-180.0
VB -7.
ASTM D41
lureM890TG Base or 120TG Base
Torch -applied
Flexible FASTor Flexible FASTDT (RIBBON, 121nch o.c.)
-307.5
VB -8.
ASTM D41
SureMB 90TG Base or 120TG Base
Torch -applied
Flexible FAST or Flexible FAST DT (RIBBON, 6 -inch o.c.)
T -495.0
19. An optional air/vapor barrier of VapAir Seal MD, self -adhered to the deck or to a loose -laid FBC Approved gypsum thermal barrier, maybe installed atop steel roof decks for System Types B-1, B-2, C-1, C-2, D-1 and D-
2 prior to installation of the roof assemblies noted herein.
20. The following insulations aie interchangeable within the scope ofthis Evaluation Report
➢
H -Shield b
A -Shield NH;
➢
InsulBase b
I'InsulBase NH;
➢
H -Shield CG 4,
H -Shield CG NH;
➢
SecurShield b
SecurShield NH;
➢
H -Shield HD b
H -Shield HD NH;
➢
SecurShield HD b
SecurShield HD NH;
➢
H -Shield HD90 b
H -Shield HD90 NH;
D
SecurShield HD Plus b
SecurShield HD Plus NH.
21. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
NEMO ETC, LLC Evaluation Report 033680.09.10-R24 for FL34083.1124
Certificate of Authorization #32455 6' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 24:06/08/2020
©2019, NEMO ETC, LLC Carlisle Sure -Weld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 4 of 87
NNEMOjetc.
-RECOVERTABLE 7C: STEEL
PLATE-BONDED•OCOVER
All areas whele tile eXiStinqmttol do not toy flush tile rove 0.
panels on underlying porlin $hall o 2S -inch diameter pilot hole pre -drilled into the panel prior to driving the Purlin Fastener into the purlin
System Substrate Insulation Layer Attachment MDP
No. Roof Cover/Adhesive
(Note 1) (Note 5) Fasteners (Note 11) Spacing (psf)
RHINOBOND SYSTEMs:
Existing standing seam or lap seam metal
One or more layers, any
Carlisle HP Purlin Fasteners or
Sure -Weld (minimum 60 -mil) or Sure -Weld
R46
roof covers having min. 16 ga. (0.0598 -inch)
RetroDriller Fasteners and RHINOBOND
12 -inch o.c. along
EXTRA bonded to RHINOBOND Insulation Plate
to max. 3/16 -inch thick steel purlins spaced
combination,
preliminarily fastened
Insulation Plate (TPO) are fastened
purlins
(TPO) with RHINOBOND tool per manufacturer's
-30.0
max. 1204nch o.c
through purlins g P
instructions.
Existing standing seam or lap seam metal
One or more layers, any
Carlisle HP Pullin Fasteners or
Sure -Weld or Sure -Weld EXTRA bonded to
R47
roof covers having min. 16 ga. (0.0598 -inch)
combination,
RetroDriller Fasteners and RHINOBOND
6 -inch o.c. along
RHINOBOND Insulation Plate (TPO) with
to max. 3/16 -inch thick steel purlins spaced
preliminarily fastened
Insulation Plate (TPO) are fastened
purlins
RHINOBOND tool per manufacturers
-37.5
max. 126 -inch o.c.
through purlins H P
instructions.
Existing standing seam or lap seam metal
One or more layers, any
Carlisle HP Purlin Fasteners or
Sure -Weld or Sure -Weld EXTRA bonded to
R-48
roof covers having min. 16 ga. (0.0598 -inch)
combination,
RetroDriller Fasteners and RHINOBOND
12 -inch o.c. along
RHINOBOND Insulation Plate (TPO) with
to max. 3/16 -inch thick steel purlins spaced
fastened
Insulation Plate (TPO) are fastened
purlins
RHINOBOND tool per manufacturers
-37.5
max. 60 -inch o.c.
preliminarily
through to purlins
instructions.
Existing standing seam or lap seam metal
One or more layers, any
Carlisle HP Purlin Fasteners or
Sure -Weld (minimum 60 -mil) or Sure -Weld
R49
roof covers having min. 16 ga. (0.0598 -inch)
RetroDriller Fasteners and RHINOBOND
12 -inch o.c. along
EXTRA bonded to RHINOBOND Insulation Plate
to max. 3/16 -inch thick steel purlins spaced
combination,
reliminarilfastened
py
Insulation Plate (TPO) are fastened
purlins
(TPO) with RHINOBOND tool per manufacturers
4 5.0
max. 60 -inch o.c..
through to purlins g p
instructions.
Existing standing seam or lap seam metal
One or more layers, any
Carlisle HP Purlin Fasteners or
Sure -Weld (minimum 60 -mil) or Sure -Weld
R-50
roof covers having min. 16 ga. (0.0598 -inch)
combination,
RetroDriller Fasteners and RHINOBOND
6 -inch o.c. along
EXTRA bonded to RHINOBOND Insulation Plate
to max. 3/16 -inch thick steel purlins spaced
reliminarilfastened
py
Insulation Plate (TPO) are fastened
purlins
(TPO) with RHINOBOND tool per manufacturers
_52.5
max. 120 -inch o.c.
through to purlins
instructions.
Existing standing seam or lap seam metal
One or more layers, any
Carlisle HP Purlin Fasteners or
Sure -Weld or Sure -Weld EXTRA bonded to
R-51
roof covers having min. 16 ga. (0.0598 -inch)
RetroDriller Fasteners and RHINOBOND
6 -inch o.c, along
RHINOBOND Insulation Plate (TPO) with
to max. 3/16 -inch thick steel purlins spaced
combination,
preliminarily fastened
Insulation Plate (TPO) are fastened
purlins
RHINOBOND tool per manufacturers
_67.5
max. 6o -inch o.c.
throu hto urlins
instructions.
ISOWELD INDUcrioN WELDINGSYSTEM:
Existing standing seam or lap seam metal roof
One or more layers, any
SFS Purlin Fastenerwith SFS isoweld®
Sure -Weld or Sure -Weld EXTRA bonded to SFS
R-52
covers having min. 16 gauge (0.0598 inch), 50
combination,
TPO Plates (FI-P-6.8-TPO) are fastened
12 -inch o.c. along
isoweld® TPO Plates with SFS isoweld® 3000
-37.5
ksi steel purlins spaced max. 60 -inch o.c.
preliminarily fastened
through to purlins
purlins
stand-up tool.
Existing standing seam or lap seam metal roof
One or more layers, any
SFS Purlin Fastenerwith SFS isoweld®
Sure -Weld or Sure -Weld EXTRA bonded to SFS
R-53
covers having min. 16 gauge (0.0598 inch), 50
combination,
TPO Plates (FI-P-6.8-TPO) are fastened
c.
6 -inch o.along
isoweld® TPO Plates with SFS isoweld® 3000
-90.0
ksi steel purlins ins spaced max. 60 -inch o.c.
preliminarily fastened
through to purlins
stand-up tool.
NEMO ETC, LLC Evaluation Report 033680.09.10-R24 for FL14083-R24
Certificate of Authorization #32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 24: 06/08/2020
©2019, NEMO ETC, LLC Carlisle Sure -Weld TPO Single Ply Roof Systems, (717) 245-7264 Appendix 1, Page 81 of 87