Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Fuel.Gas_Ferrante-3604 Twin Lakes Terr_SupportingDocs
Copyright 2019 National FireProtection Association (NFPAS). Licensed by agreement to Tan Fite FOR INDIVIDUAL USE ONLY and dowdoadad on 12/112019. No reproduction or transmission in any form pon nided without written pemrission of NFPA0. For inquiries or access for multiple users, w to report unsuUodzed use, contact licensing®mpa.org. 5&108 LIQUEFIED PETROLEUM GAS CODE A Table 16.1(f) Semirigid Copper Tubing 1.50 DnENDED USE: Tube Sizing Between First -Stage (High -Pressure) Regulator and Second -Stage. (I: Preseive) Regulator. Note: All table envies are rounded to 3 significant digits. *Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products. [54:Table 6.3.1(e)] 2020 Edition Shaded text= Revisions. A= Text deletions and figure/table revisions. e = Section deletions. N = New material. Tube Size (in.) K & L: '/4 %'/2 s/a e/4 1 lY4 1'/s 2 Nominal: ACR.- '/q V2 % a/4 US 1%s 15% - - Outside: 0.875 0.500 0.625 0.750 0,875 1,125 1.375 1.625 2.125 Inside:* 0.305 0.402 0.527 0.652 0.745 0.995 1.245 1.481 1.959 Length (ft) Capacity in Thousands of Stu per Hour 10 513 1,060 2,150 3,760 5,330 11,400 20,500 32,300 67,400 20 352 727 1,480 2,580 3,670 7,830 14,100 22,200 46,300 30 283 584 1,190 2,080 2,940 6,290 11,300 17,900 37,200 40 242 500 1,020 1,780 2,520 5,380 9,690 15,300 31,800 50 215 443 901 1,570 2,230 4,770 8,590" 13,500 28,200 60 194 401 816 1,430 2,020 4,320 7,780 12,300 25,600 70 179 369 751 1,310 1,860 3,980 7,160 11,300 23,500 80 166 343 699 1,220 1,730 3,700 6,660 10,500 21,900 90 156 322 655 1,150 1,630 3,470 6,250 9,850 20,500 100 147 304 619 1,080 1,540 3,280 5,900 9,310 19,400 125 131 270 549 959 1,360 2,910 5,230 8,250 17,200 150 118 244 497 869 1,230 2,630 4,740 7,470 15,600 175 109 225 457 799 1,130 2,420 4,360 6,880 14,300 200 101 209 426 744 1,060 2,250 4,060 6,400 13,300 250 90 185 377 659 935 2,000 3,600 5,670 11,800 300 81 168 342 597 847 1,810 3,260 5,140 10,700 350 75 155 314 549 779 1,660 3,000 4,730 9,840 400 70 144 292 511 725 1,550 2,790 4,400 9,160 450 65 135 274 480 680 1,450 2,620 4,130 8,590 500 62 127 259 453 643 1,370 2,470 3,900 8,120 550 59 121 246 430 610 1,300 2,350 3,700 7,710 600 56 115 235 410 582 1,240 2,240 3,530 7,350 650 54 111 225 393 558 1,190 2,140 3,380 7,040 700 51 106 216 378 536 1,140 2,060 3,250 6,770 750 50 102 208 364 516 1,100 1,980 3,130 6,520 800 48 99 201 351 498 1,060 1,920 3,020 6,290 850 46 96 195 340 482 1,030 1,850 2,920 6,090 900 45 93 189 330 468 1,000 1,800 2,840 5,910 950 44 90 183 320 454 970 1,750 2,750 5,730 1,000 42 88 178 311 442 944 1,700 2,680 5,580 1,100 40 83 169 296 420 896 1,610 2,540 5,300 1,200 38 79 161 282 400 855 1,540 2,430 5,050 1,300 37 76 155 270 383 819 1,470 2,320 4,840 1,400 35 73 148 260 368 787 1,420 2,230 4,650 1,500 34 70 143 250 355 758 1,360 2,150 4,480 1,600 33 68 138 241 343 732 1,320 2,080 4,330 1,700 32 66 134 234 331 708 1,270 2,010 4,190 1,800 - 31 64 130 227 321 687 1,240 1,950 4,060 1,900 30 62126 220 312 667 1,200 1,890 3,940 2,000 29 60 122 214 304 648 1,170 1,840 3,830 Note: All table envies are rounded to 3 significant digits. *Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products. [54:Table 6.3.1(e)] 2020 Edition Shaded text= Revisions. A= Text deletions and figure/table revisions. e = Section deletions. N = New material. Application Designed to reduce first stage pressure of 5 to 20 PSIG down to burner pressure, normally 11" w.c. Ideal for medium commercial installations, vapor meter installations and normal domestic loads. Features • 90 degree right angle inlet to outer connection for meter or standard installations. • Large vent helps to prevent blockage and has''/." F NPT for vent piping. • Nth 15 PSIG inlet pressure, regulator is designed to not pass more than 2 PSIG with the seat disc removed. • Replaceable valve orifice and valve seat. • Straight line valve closure reduces wear on seat disc • Unique bonnet vent profile minimizes vent freeze over when properly installed. • Large molded diaphragm is extra sensitive to pressure changes. • Built in pressure tap has plugged '/ F. NPT outlet. Plug can be removed with a 3116" hex alien wrench. • Select Brown Finish Right Angle Design Can mount directly to vapor meter. It is also suitable for mounting directly to the house piping. It will retrofit into existing installations that are currently using a 90 degree, right angle regulator. Materials Body........................................................................... Die Cast Zinc Bonnet........................................................................ Die Cast Zinc NozzleOrifice ......................................................................... Brass Spring...................................................................................... Steel Valve Seat Disc ..................................................... Resilient Rubber Diaphragm ......................... Integrated Fabric and Synthetic Rubber LV4403Bfi6RA LV4403B66RAB— s/" F. NPT W F. NPT 1 3/16- M rl 171 w/llloomtlngHfliodkelt INE= MMMMMMMMMM MMMMMMMMMM 1 1 11 1 11 �.1 it 111 1 11 1 II I 11 111 1 111 111 •11 • 111 1 PSIG Inlet 10 19" to 13" w.c. I Over Inlet I 1,000,000 Maximum flow Is bread w 10 PSIG inlet m! 9• w.m delivery pmmm. •• Mourting Bracket Included. �^^ �M 100 Repo Dr. Ebn, NC 27244 USA w ..regopmducts.mm +1 (336) 4494707 REM•