Loading...
HomeMy WebLinkAboutPermit Application Emanuel Mirglilo Product Approvals Set 39/28/2020 Florida Building Code Online SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us j SCIS Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL12512-R7 Revision 2017 Approved l7 ---1-Z \ AlphaProTech Engineered Products, Inc. 301 S. Blanchard St. Valdosta, GA 31601 (229)242-1931 bhayden@alphaprotech.com Bruce Hayden bhayden@alphaprotech.com Bruce Hayden 301 S. Blanchard St. Valdosta, GA 31601 (229)242-1931 bhayden@alphaprotech.com Daniel La Face 301 South Blanchard Street Valdosta, GA 31601 (229)242-1931 Ext 237 dlaface@alphaprotech.com Roofing Underlayments Evaluation Report from a Florida Registered Archite Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE -74021 Quality Assurance Entity TI RADCO LLP dba RADCO A Twining Company Quality Assurance Contract Expiration Date 07/02/2022 Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvG4Aty8UaHdl4A517SHt9cRb66A%2fgTl5KSkFiGQsKFKw%3d%3d 1/3 9/2812020 Florida Building Code Online Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised Summary of Products FL12512 R7 COI APT15001.4 2017 FBC Underlay! Standard ASTM D226 ASTM D4533 ASTM D4869 Method 1 Option D 08/13/2019 08/13/2019 08/20/2019 10/15/2019 08/05/2020 FL # Model, Number or Name Description 12512.1 REX SynFelt w i Synthetic Roof Underlayment Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Installation Instructions FL12512 R7 II APT15001.4 2017 FBC fina1.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Ye Evaluation Reports FL12512 R7 AE APT15001.4 2017 FBC final.pdf Created by Independent Third Party:` Ye 12512.2 TECHNO 5B 25 Synthetic Roof Underlayment Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure. N/A Other: See evaluation report for limits of use. Installation Instructions FL12512 R7 II APT15001.4 2017 FBC final.pdf Verified By: Zachary R. Priest PE -74021 I Created by Independent Third Party: Ye Evaluation Reports iI FL12512 R7 AE APT15001.4 2017 FBC i final.pdf jI{ Created by Independent Third Party: Ye 12512.3 TECHNO SB 50 Synthetic Roof Underlayment�� Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Installation Instructions FL12512 R7 II APT15001.4 2017 FBC I final.pdf i Verified By: Zachary R. Priest PE -74021 Created by Independent Third Party: Ye Evaluation Reports FL12512 R7 AE APT15001.4 2017 FBC https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgvG4Aty8UaHdi4A517SHt9cRb66A%2fgTl5KSkFiGQsKFKw%3d%3d 2/3 9/28/2020 12512.4 Florida Building Code Online TECHNO SB Ultra Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. 12512.5 TECHNOply Synthetic Roof Underlayment Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. final.pdf Created by Independent Third Party: Ye Synthetic Roof Underlayment Installation Instructions FL12512 R7 II APT15001.4 2017 FBC final.pdf Verified By: Zachary R. Priest PE -74021 Created by Independent Third Party: Ye Evaluation Reports FL12512 R7 AE APT15001.4 2017 FBC final.pdf Created by Independent Third Party: Ye Synthetic Roof Underlayment Installation Instructions FL12512 R7 II APT15001.4 2017 FBC 6 final.pdf Verified By: Zachary R. Priest 74021 I Created by Independent Third Party: Ye Evaluation Reports FL12512 R7 AE APT15001.4 2017 FBC final.pdf Created by Independent Third Party: Ye IME Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility __at Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records n mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *P Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email addre! provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to sup provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapt Product Approval Accepts: https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvG4Aty8UaHdl4A517SHt9GRb66A%2fgTl5KSkFiGQsKFKw%3d%3d 3/3 r a' Certificate of Authorization No. 29824 CREEK17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 6T" EDITION (2017) Manufacturer: ALPHA PROTECH ENGINEERED PRODUCTS, INC. Issued August 12, 2019 301 South Blanchard Street Valdosta, GA 31601 (229) 242-1931 http://www.alphaprotech.com Manufacturing Locations: Valdosta, GA Quality Assurance: RADCO, Inc. (QUA1990) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1, 1518.2, 1518.4 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) AEP -009-02-01 ASTM D 4533 2015 PRI Construction Materials Technologies (TST5878) AEP -017-02-01 ASTM D 226 2009 ASTM D 4869 2016 PRI Construction Materials Technologies (TST5878) AEP -022-02-01 ASTM D 4533 2015 PRI Construction Materials Technologies (TST5878) AEP -023-02-01 ASTM D 4533 2015 ASTM D 226 2009 ASTM D 4869 2016 PRI Construction Materials Technologies (TST5878) AEP -023-02-02 ASTM D 5043 2015 PRI Construction Materials Technologies (TST5878) 20T0001 ASTM D 4533 2015 ASTM D 226 2009 PRI Construction Materials Technologies (TST5878) 20T0002 ASTM D 4533 2015 ASTM D 226 2009 PRI Construction Materials Technologies (TST5878) 20T0003 AC 188 2012 PRI Construction Materials Technologies (TST5878) 20T0004 AC 188 2012 PRI Construction Materials Technologies (TST5878) 20T0006 ASTM D 226 2009 PRI Construction Materials Technologies (TST5878) 20T0007 ASTM D 226 2009 RADCO, Inc (TST1987) RAD -5212 AC 188 2012 RADCO, Inc (TST1987) RAD -4987 ASTM D 4533 2015 Ramtech Laboratories, Inc. (TST6127) 13075-04-08 AC 188 2012 APT15001.4 FL12512-R7 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3_ The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL. SERVICES. LLC PRODUCT DESCRIPTION REX'rm TECHNOply ALPHA PROTECH ENGINEERED PRODUCTS, INC. Underlayments A mechanically attached, woven polypropylene underlayment (nominal weight = 2.56 ib/100e) used an alternative to ASTM D 226, Type I and Type II roofing underlayments with a minimum tear strength per ASTM D 4533 of 20 pounds, A mechanically attached, woven polypropylene underlayment (nominal weight = 2.05 Ib/100ft) used an alternative to ASTM D 226, Type I and Type li roofing underlayments with a minimum tear strength per ASTM D 4533 of 20 pounds, TECHNO SB 25 A mechanically attached, woven polypropylene underlayment (nominal weight = 2.2 Ib/1 ON) used an alternative to ASTM D 226, Type I and Type 11 and ASTM D 4869, Type II and IV roofing undedayments with a minimum tear strength per ASTM D 4533 of 20 pounds. TECHNO SB 50 A mechanically attached, woven polypropylene underlayment (nominal weight = 2.00 Ib/100ft2) used an alternative to ASTM D 226, Type I and Type II and ASTM D 4869, Type II and IV roofing underlayments with a minimum tear strength per ASTM D 4533 of 20 pounds TECHNO SB Ultra A mechanically attached, woven polypropylene underlayment (nominal weight = 5.5 Ib/100ftz) used an alternative to ASTM D 226, Type I and Type Il and ASTM D 4869, Type 11 and IV roofing underlayments with a minimum tear strength per ASTM D 4533 of 20 pounds. APPLICATION INSTRUCTIONS Deck Type: The roof deck shall be constructed of closely fitted, solid sheathing for new or existing construction. New construction in the HVHZ shall be min. 19/32 in. plywood. Sheathing shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. Attachment method: Undedayment shall be attached in accordance with the FBC Table 1507.1.1 and (Non-HVHZ): manufacturer's installation instructions Attachment method Underlayment shall be installed with a minimum 4 -inch head lap and minimum 6 -inch (HVHZ): end lap and be fastened as specified in FBC Section 1518.2. Allowable roof coverings: Mechanically attached roof systems as prescribed in FBC Section 1507.1.1. (Non-HVHZ) Allowable roof coverings: Mechanically attached asphalt shingles, composite shingles, metal roof panels and (HVHZ) shingles, or wood shakes and shingles APT15001.4 FL12512-R7 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. j ALPHA PROTECH ENGINEERED PRODUCTS, INC. CREEKUnderlayments TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 5) The roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be installed in accordance with FBC requirements. 6) Roof slope limitations shall be in accordance with FBC requirements. 7) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in success courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 8) Contact the manufacturer when installing at temperatures below the minimum application temperature. 9) The underlayment may be used as described in other current FBC product approval documents. 10) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underlayment to the roof deck. 11) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated. 12) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. 11%J1111111#11111 ;,\CENS' s-- 2019.08.1 No 74021 2 09:42:55 -13 -04'00' x-33 STATE OF 44/+` a p R O: ����� Zachary R. Priest, P.E. No. 21 ,fr�jQNA- E 0' OrganFloridization No. 0on ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT APT15001.4 FI -12512-R7 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Florida Building Code Online . . 7,9-M SAM A5AM Submit Surcharge Stats & Facts Publications , Contact Us BCIS Site Map ` Links i Search d bp�r Product Approval 1/4USER: Public User TAS 100 1995 Product Approval Menu > Product or Application Search > Application List > Application Detail 2003 FL # FL17796-R1 UL1897 Application Type Revision 2006 Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Atlantic Metal II of Vero Beach Address/Phone/Email 4020 43rd Avenue Vero Beach, FL 32960 (772) 257-5730 FLvalidation@yahoo.com Authorized Signature William Lasky FLvalidation@yahoo.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE -49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 06/11/2025 Validated By Zachary R. Priest, P.E. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL17796 R1 COI FL 17796 1.0 Nail Strip 24GA over 15 32 Plywood - 2017 Code RR.pdf Standard Year TAS 100 1995 TAS 125 2003 TAS110 2000 UL1897 2012 UL 580 2006 https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgs%2bbt23mL8HofjKv7zYVGsdytKRV64OWTjfC3zOhF3BRA%3d%3d 1/3 9/28/2020 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Florida Building Code Online Method 1 Option D 01/24/2018 02/14/2018 02/20/2018 04/10/2018 FL #p !Model Number or Name ; Description 117796.1 11 1/2" Nail Strip ; 1 1/2" Nail Strip 15 1/2" Wide over 1/2" Plywood - HVHZ. I i Complianr with FBC 2017 6th ed. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.OPSF Other: 78.5 psf @ 11" o.c. -116.0 psf @ 6 1/2" o.c. Install per manufacturers details. For use in HVHZ Zones. 17796.2 11 1/2" Snap Lock Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.OPSF Other: -86.0 psf @ 24" o.c. -108.5 psf @ 12" o.c. -116.0 psf @ 6" o.c. Install per manufacturers details. For use in HVHZ Zones, 17796.3 1 1" Mechanical Lock Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +NIA/-101.OPSF Other: -63.5 psf @ 24" o.c. -101.0 psf @ 6" o.c. Install per manufacturers details. For use in HVHZ Zones. Installation Instructions FL17796 R1 II FL 17796 1.5 Nail Strip 24GA over Plywood - 2017 Code RR.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17796 Rl AE FL 17796 1.5 Nail Strip 24GA over Plywood - 2017 Code RR.pdf Created by Independent Third Party: Yes 1 1/2" Snap Lock 24 Ga. over 16" Wide 1/2" Plywood Installation Instructions FL17796 Rl II FL 17796 1.5 Snap Lock 24GA SS over Plywood - 2017 Code RR.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17796 Rl AE FL 17796 1.5 Snap Lock 24GA SS over Plywood - 2017 Code RR.pdf Created by Independent Third Party: Yes 1" Mechanical Lock 0.032" Aluminum 16" Wide over 1/2" Plywood Installation Instructions FL17796 R1 II FL 17796 1.0 Mechanical Lock 032 or .040 Alum - 2017 Code RR.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17796 Rl AE FL 17796 1.0 Mechanical Lock .032 or .040 Alum - 2017 Code RR.pdf Created by Independent Third Party; Yes 117796.4 1" Nail Strip 1" Nail Strip 24 Ga. 16" Wide over 1/2" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +N/A/-153.SPSF Other: -59.75 psf @ 16" o.c. -101.0 psf @ 6 3/4" o.c. -153.5 psf @ 6 3/4" o.c. 12" o.c. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL17796 Rl II FL 17796 1.0 Nail Strip 24GA over 15 32 Plywood - 2017 Code RR.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17796 Rl AE FL 17796 1.0 Nail Strip 24GA over 15 32 Plywood - 2017 Code RR.pdf Created by Independent Third Party: Yes 17796.5 11" Snap Lock 1" Snap Lock 24 Ga. 17" Wide 1/2" Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131.OPSF Other: -67.3 psf @ 24" o.c. -131.0 psf @ 6" o.c. Install per manufacturers details. For use in HVHZ Zones. Installation Instructions FL17796 Rl II FL 17796 1.0 Snap Lock 24GA SS over Plywood - 2017 Code RR.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17796 R1 AE FL 17796 1.0 Snap Lock 24GA SS over Plywood - 2017 Code RR-Pdf Created by Independent Third Party: Yes 17796.6 ; 5V Crimp 26 Ga. 5V Crimp Roof Panel over Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Installation instructions FL17796 Rl II FL 17796 5V Crimp 24GA or 26GA Min. Thru Fastened over Plywood - 2017 Code RR.pdf Verified By; Locke Bowden, P.E. 49704 https://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgs%2bbt23ML8HofjjKv7zYVGsdytxRV64OWTjfC3zOhF38RA°/"3d%3d 2/3 9128/2020 Florida Building Code Online Design Pressure: +N/A/-156.5PSF Created by Independent Third Party: Yes Other: -108.5 psf @ 12" o.c. -156.5 psf @ 6" o.c. Install per ( Evaluation Reports manufacturers details. For use in HVHZ Zones. FL17796 R1 AE FL 17796 5V Crimp 24GA or 26GA Min. Thru Fastened over Plywood - 2017 Code RR.pdf Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copytght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mailto this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M C577 W1 EE 09 6ECt11 [ '4tk.' RIGS, ` https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs%2bbt23mL8HofjKv7zYVGsdytxRV640WTjfC3zOhF3BRA%3d%3d 3/3 Vero Beach, FL 32966 (772)257-5730 Compliant with Florida Building Code 2017 (6t' e.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant Quality Assurance Program: Keystone Cerifications FBC Sections: 1504.3.2, 1506, 1507.4.3, 1517, 1518.9, 1523.6.5.2.4 Underlayment: See Section 1507, Table 1507.1.1 24GA steel FOR HVHZ: ASTM A653 G90 FOR NON-HVHZ: ASTM A792 unpainted or painted w/ Valspar Fluropon See Table 15'x4" Wide Female Rib: 1 %" tall Male Rib: %" tail rib w/ slotted strip Panel Seam: Snap Lock Panel Fastener: Corrosion Resistant Compliant; ALL to penetrate min. !" through plywood Min. 50ksi Through Panel Slot: (1) #12-11 x 1" tall Pancake Type A In Pan of Panel: (2) #10-11 x 1" Eclipse Head Type A FOR 8y±jZ Constructs 19/32" or greater APA Plywood or wood plank. In reroofing applications add 15/32" plywood where roof is less than 19/32" thick (min. 15/32") the attachment of the decking shall be no less than 8D annual ring shank nails@ 6"o.c. FOR NON-HVHZ Construction: min. 15/32" APA Plywood over supports at max. 24" o.c. Fire Barrier: Any approved fire barrier having a current NOA. **Design Pressure: Panel Slot Fastener Spacing: I Panel Pan Fastener Spacing: -78.5 PSF 11" O.C. N/A -116 PSF 6 %" O.C. i _12" O.C. 24GA steel FOR HVHZ: ASTM A653 G90 FOR NON-HVHZ: ASTM A792 unpainted or painted w/ Valspar Fluropon See Table 1507.4.3 2 16" Wide Rib:1 %" Panel Seam: Snap Lock Roof Panel Clip:1500SNS, Fixed,18GA, 3 K" Long Min. 50ksi Corrosion Resistant Clip Fastener: (2) #12-11 Pancake Type A to penetrate min. X" thru plywood. FOR HVHZ ConstructIM 19/32" or greater APA Plywood or wood plank. In reroofing applications add 15/32' plywood add 15/32" plywood where roof is less than 19/32" thick (min. 15/32") the attachment of the decking shall be no less than 8D annual ring shank nails @ 6"o.c. FOR NON-HVHZ Construction: min. 15/32" APA Plywood over supports at max. 24" o.c. Fire Barrier: Any approved fire barrier having a current NOA. "Design Pressure: + Clip Spacing: Fasteners per Clip: -86.0 PSF 24" O.C. E 2 -108.5 PSF 12" O.C. 2 I -116.0 1 6" O.C. 2 .032" or .040" Aluminum, 3105 H-24 unpainted or painteo witn vaispar riuropon corrrormang iu rrn. Lvi. V Cu. wane. LL.. nal 16" Wide Rib Height: 1" Panel Seam: 180' Seam, Double Lock w/ mechanical seamen Roof Panel Clip: UC -3 Stainless Steel Butterfly Clip Assembly, Two -Piece Slider Corrosion Resistant Clip Fastener: (2) #12-11 x 1" Pancake Type A to penetrate min. t" thru plywood FOR HVHZ Construction. 19/32" or greater APA Plywood or wood plank. In reroofing applications add 15/32" plywood where roof is less than 19/32" thick (min. 15/32") the attachment of the decking shall be no less than 81) annual ring shank nails @ 6"o -c. FOR NON-HVHZ Construction: min. 15/32" APA Plywood over supports at max. 24" o.c. Fire Barrier: Any approved fire barrier having a current NOA. **Design Pressure: Clip Spacing: Fasteners per Clip: -63.5 PSF 24" O.C. 2 -101.0 PSF 6" O.C. __. 2_ 24GA Steel, conformingto FBC 2017 6�' ed. Yield Strength: Min. 50 ksi Self -adhered roofing underlayment min. 40 milthickness. 16" Wide Female Rib: 1" tail Male Rib: 4" tall rib w/ slotted strip Panel Seam: Snap lock Panel Fastener: Corrosion Resistant Compliant, ALL to penetrate 34" min. through plywood Throueh Panel Slot: 11) #10-13 x 1" GP Pancake Type A In Pan of Panel: (2) #10-11x 1" Eclipse Head Type A substrate: Min. 15/32" APA Plywood over supports at max. 24" o.c. Min. slope shall comply w/ FBC 2017 61 ed. **Design Pressure: Panel Slot Fastener Spacing: Panel Pan Fastener Spacing: -59.75 PSF 16" O.C. N/A -101.0 PSF 6 %" O.C. N/A -153.5 PSF 6 ." O.C. 24GA steel FOR HVHZ: ASTM A653 G90 FOR NON-HVHZ: ASTM A792 unpainted or pa 17" Wide Rib Height: 111 Panel Seam: Snap Lock Roof Panel clips: 1000SNS, Fixed, 18GA, 3 K" Long Corrosion Resistant Clip Fastener; (2) #12-11 Pancake Head Type A to penetrate min. YV through plywood Min. 50ksi FOR HVHZ Construction: 19/32" or greater APA Plywood or wood plank, in reroofing applications add 15/32" plywood where roof is less than 19/3r thick (min. 15/32') attachment of the decking shall be no less than 8D annual ring shank nails @ 6"oc. FOR NON-HVHZ Construction: min. 15/32" APA Plywood over supports at max. 24" o,c. Fire Barrier. Any approved fire barrier having a current NOA. Min. slope shall comply w/ FBC 2017 6th ed, 1 -67.3 PSF 1 24" O.C. 1 2 1 FOR HVHZ: ASTM A653 G90 FOR NON-HVHZ: ASTM A792 unpainted or painted w/ Valspar Fluropon See Table 1507.4.3 (2) 24" Wide Rib Height: 3/8' major rib min. 50ksi Fire Barrier- VV Georgia Pacific "Dens Deck" or approved equal. FOR HVHZ Cgnstruttion: 19/32" or greater APA Plywood or wood plank. In reroofing applications add 15/32" plywood where roof is less than 19/32' thick (min. 15/32") the attachment of the decking shall be no less than 81) annual ring shank nails @ Voc. FOR NON-HVHZ construction: min. 15/32" APA Plywood ever supports at max. 24"oc. Min. slope shall comply w/FBC 2017 60, ed. "Design Pressure: Fastener Pattern: Fastener Spacing: -108.5 PSF Panel Ri♦ OX. '156.5 PSF Panel RLb, Reference Data: "DESIGN PRESSURE INCLUDESA SAFETY MARGIN OF 2.1 Force Engineering & Testing ("FST -5328) 72-019OT-07 TA5 125-03 JUL 580-06'/UL 1897-122) Farabaugh Engineering & Testing (TST-1564) 1349-07 TAS 100-95 PRI Asphalt Technologies TAS 110-00 (ASTM G 155/ASTM 13 127) Force Engineering & Testing (TST-5328) 72-OISOT-07 TAS 125-03 (UL 580-06'/UL 1897-122) Farabaugh Engineering & Testing (TST-1654) T107-07 TAS 100-95 Force Engineering & Testing (TST-5328) 72-019I7-07 TAS 125-03 (UL 5813-0 '/UL 1897-122) Farabaugh Engineering & Testing (TST-1654) T232-07 TAS 100-95 Force Engineering & Testing (TST-5328) 72-03147-06 UL 580-941/UL 1897-122 Farabaugh Engineering & Testing (T5T-1654) 7I58-07 TAS 100-95 Force Engineering &Testing (TST-5328) 72-021OT-07 TAS 125-03 (UL 58G -06!/U L 1897-122) Farabaugh Engineering & Testing (TST-1654) T233-07 TAS 100-95 Force Engineering & Testing (TST-5328) 115-0172T-07 A-E TAS 125-03 JUL 580-061JUL 1897-122) Farabaugh Engineering & Testing (TST-1654) 7130-07 TAS 100-95 TM -08 TAS 100-95 1, UL 580-94 test standard is equivalent to UL 580-06 test standards. 2 UL 1897-98 test standard is equivalent to UL 189712 test standards. Limitations: 1. Underlayment to be compliance with current Florida Building Code (F8C)2017 6Til ed.. see Chart 1507.1A 1 Minimum slope to be compliant with Florida Building Code 2017 V1 ed., and per with Manufacturer's installation reference. 1 Products are compliant with State of Florida product approval per Rule 6IG20-3. Compliance Method: I -D 4. Engineering analysis for "project specific approval by local authority's w/jurisdiction is allowed by other registered engineers, S. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance %,v/FBC 2017 61h ed., Chapter 22 Steel, Chapter 23 Wood and chapter 16 Structural Loading, 7. This report does not imply warranty, installation, recommended product use outside of this report. Certificate"of Independence: Locke Bowden, P.E. does not have, not will acquire a financial interest in any company manufacturing or distributing products under this evaluation. Locke Bowden, P.E. isnot owned, operate #o#WNftV40 by any company, manufacturer or distributing products under report. BO Locke Bowden, P.E FL Reg. no. 49704 7 - STATE OF 'PLOWV *rN N ONA'l- fill, it I alk0l"It ATLANTIC METAL 11 OF VERO BEACH, INC. 5V Crimp 24GA or 26GA Min. Thru Fastened over Plywood — INSTALLATION DETAILS SUOSTR-UCTURZ 0-12"1 M -W M MT mi jM='F'- ATLANTIC METAL II OF VERO BEACH, INC. 5V Crimp 24GA or 26GA Min. Thru Fastened over Plywood — INSTALLATION DETAILS IA EDGE 5v C IM PANEL- AS E- rtR #j g s E N OF RIO'Ge OVER WOOD DECK ISOMETRIC VIEW OF RIDGE OVER WOOD DECK ATLANTIC METAL 11 OF VERO BEACH, INC. 5V Crimp 24GA or 26GA Min. Thru Fastened over Plywood — INSTALLATION DETAILS ATLANTIC METAL 11 OF VERO BEACH, INC. 5V Crimp 24GA or 26GA Min. Thru Fastened over Plywood — INSTALLATION DETAILS MAMCC -144ZAMfiC PLIM000 SHEAUOR i'sy gs; I fe—F a, WA70� "m'tv'z wk' 4r c— V E a 91K3fiocf To I' MJE V* w4u To ncl-ET