LOAD CALCULATIONS
M
Z
FF
W•+ pwoo
2 c°
U m
NOTES: EXISTING HVAC SYSTEM IS A. 36,000 BTUH SYSTEM
at
W > m•o
AND IS UNDERSIZED FOR THE HOME WHICH REQUIRES
37,863 BTUH. 6,000 BTUH, MULTIPLE FAN SPEED
N •C .0
H z
MINI -SPLIT INSTALLED IN MASTER SUITE WILL
ACCOMODATE EXISTING EXCESS LOAD REQUIREMENT.
I� Q m O
EXISTING HVAC SYSTEM WILL REMAIN AS -IS.
y
d C A ? L
_
J
2
HVAC SYSTEM RENOVATION SPECIFICATIONS
t> y V
MASTER SUITE MINI -SPLIT SYSTEM:
Z Z W
H
• MITSUBISHI M-SERIES 6,000 BTU/H WALL -MOUNTED HEAT PUMP
a
INDOOR UNIT: MSZ-FH06NA; OUTDOOR UNIT; MUZ-FH06NA
ci
AHRI CERTIFIED REFERENCE NUMBER: 201754426
• SEER: 33AD; HSPF: 13.50
Q
COOLING CAPACITY (BTUH): 1,700 (MIN) - 9,000 (MAX)
>
•
• HEATING CAPACITY (BTUH) (@47'F): 1,600 (MIN), 14,000 (MAX)
FLORIDA ENERGY CONSERVATION
CODE COMPLIANCE
2017 FBC, EXISTING BUILDING, SECTION 701.2 CONFORMANCE:
AN EXISTING BUILDING OR PORTION THEREOF SHALL NOT BE ALTERED
SUCH THAT THE BUILDING BECOMES LESS SAFE OR ENERGY EFFICIENT
THAN ITS EXISTING CONDITION.
ENERGY RATING INDEX (ERI) COMPARISON REPORT CALCULATED BY
PREPARED BY.
USE OF ENERGYGAUGE USA. FBC 6TH EDITION CODE COMPLIANCE
SOFTWARE. ENERGY CONSUMPTION OF THE SANCHO RESIDENCE PRIOR
Kathleen Connolly
DATE:
HVAC SYSTEM RENOVATION LAYOUT
TO INSTALLATION OF DUCTLESS MINI -SPLIT. - 13,432 kWh, ENERGY
CONSUMPTION AFTER INSTALLATION OF MINI -SPLIT = 12,392 kWh.
Se lem6er 27 2020
:
ERI COMPARISON REPORTS PROVIDED WITH PERMIT DOCUMENTATION.
3 1 "-SHE'-0"
' SCALE: 3118"�1'-0"
NOTE: FLOOR PLAN IS DIAGRAMMATIC AND FOR THE SOLE PURPOSE OF
THE SANCHO RESIDENCE IS MORE ENERGY EFFICIENT WITH THE ADDITION
1 OF 1
JOB NO.:
HEATING & COOLING LOAD CALCULATIONS. MINOR DISCREPANCIES
OF THE MITSUBISHI MINI -SPLIT DUCTLESS SYSTEMS IN THE MASTER SUITE
8200910
AMONGST DIMENSIONS WILL NOT ALTER THE END RESULT.
OF THE EXISTING RESIDENCE.
���DISCONNECT SWITCH
LINE OF ROOF OVERHANG (ABOVE)
®
,
NEW MITSUBISHI MINISPLIT
M—SERIES AIR CONDITIONER
INDOOR WALL MOUNT UNIT:
MSZ-FH06NA o
OUTSIDE UNIT:
MUZ—FHO6NA
� MASTER BEDROOM
COVERED PATIO
i
W5
MASTER SUITE
,
''
ROOM ID(2)
' 0 5
,
W3 wa
386 S.F.
•i
N
o
DINING ROOM
KITGIIEN FAMILY ROOM
,
12'-8'
3 D2
ws
EXISTING GOODMAN
�ATf1 � WIG
3—TON HVAC SPLIT
'
SYSTEM
MAIN
;
'
ROOM ID (1)
'
919 S.F.
,o
.LIVING ROOM
>3Am a
O
GARAGE
1
D1 �
O
t3EDRO0M 2
We
FRONT PO�RGtIIi
10
'
ws w9
,
L�
13'-0"
22'-0°
HTq / CLq LOAD SCHEDULE
BY ROOM
ROOM/SPACE
AREA
HEATING
COOLING
(Sq. ft.)
(Btuh)
(Btuh)
MAIN:
t919
24,354
SENSIBLE:
(WHOLE HOUSE NOT
27,565
LATENT:
INCLUDING MASTER SUITE)
2,402
TOTAL:
29,967
MASTER SUITE:
ties
6,sss
SENSIBLE:
(MASTER BEDROOM, BATH
7,231
LATENT;
& W.I.C.)
sss
TOTAL:
7,896