HomeMy WebLinkAboutSurvey33'-0" 15'-0" V •L u R F o `7' LLI LEQEND and ABBREVIATIONS v a DIM. DIMENSION LINE FINISHED WALL SURFACE. W1 WINDOW OPENING I.D. f 1 3 F z REFERENCE MANUAL J CALCULATIONS V N DOOR OPENING I.D., REF. MANUAL J D7 rn (NOTE: SLIDING GLASS DOORS TO Q N BE CONSIDERED WINDOWS) nj I. WALL NUMBER I.D. REFERENCE MANUAL, J v n LOAD CALCULATIONS M Z FF W•+ pwoo 2 c° U m NOTES: EXISTING HVAC SYSTEM IS A. 36,000 BTUH SYSTEM at W > m•o AND IS UNDERSIZED FOR THE HOME WHICH REQUIRES 37,863 BTUH. 6,000 BTUH, MULTIPLE FAN SPEED N •C .0 H z MINI -SPLIT INSTALLED IN MASTER SUITE WILL ACCOMODATE EXISTING EXCESS LOAD REQUIREMENT. I� Q m O EXISTING HVAC SYSTEM WILL REMAIN AS -IS. y d C A ? L _ J 2 HVAC SYSTEM RENOVATION SPECIFICATIONS t> y V MASTER SUITE MINI -SPLIT SYSTEM: Z Z W H • MITSUBISHI M-SERIES 6,000 BTU/H WALL -MOUNTED HEAT PUMP a INDOOR UNIT: MSZ-FH06NA; OUTDOOR UNIT; MUZ-FH06NA ci AHRI CERTIFIED REFERENCE NUMBER: 201754426 • SEER: 33AD; HSPF: 13.50 Q COOLING CAPACITY (BTUH): 1,700 (MIN) - 9,000 (MAX) > • • HEATING CAPACITY (BTUH) (@47'F): 1,600 (MIN), 14,000 (MAX) FLORIDA ENERGY CONSERVATION CODE COMPLIANCE 2017 FBC, EXISTING BUILDING, SECTION 701.2 CONFORMANCE: AN EXISTING BUILDING OR PORTION THEREOF SHALL NOT BE ALTERED SUCH THAT THE BUILDING BECOMES LESS SAFE OR ENERGY EFFICIENT THAN ITS EXISTING CONDITION. ENERGY RATING INDEX (ERI) COMPARISON REPORT CALCULATED BY PREPARED BY. USE OF ENERGYGAUGE USA. FBC 6TH EDITION CODE COMPLIANCE SOFTWARE. ENERGY CONSUMPTION OF THE SANCHO RESIDENCE PRIOR Kathleen Connolly DATE: HVAC SYSTEM RENOVATION LAYOUT TO INSTALLATION OF DUCTLESS MINI -SPLIT. - 13,432 kWh, ENERGY CONSUMPTION AFTER INSTALLATION OF MINI -SPLIT = 12,392 kWh. Se lem6er 27 2020 : ERI COMPARISON REPORTS PROVIDED WITH PERMIT DOCUMENTATION. 3 1 "-SHE'-0" ' SCALE: 3118"�1'-0" NOTE: FLOOR PLAN IS DIAGRAMMATIC AND FOR THE SOLE PURPOSE OF THE SANCHO RESIDENCE IS MORE ENERGY EFFICIENT WITH THE ADDITION 1 OF 1 JOB NO.: HEATING & COOLING LOAD CALCULATIONS. MINOR DISCREPANCIES OF THE MITSUBISHI MINI -SPLIT DUCTLESS SYSTEMS IN THE MASTER SUITE 8200910 AMONGST DIMENSIONS WILL NOT ALTER THE END RESULT. OF THE EXISTING RESIDENCE. ���DISCONNECT SWITCH LINE OF ROOF OVERHANG (ABOVE) ® , NEW MITSUBISHI MINISPLIT M—SERIES AIR CONDITIONER INDOOR WALL MOUNT UNIT: MSZ-FH06NA o OUTSIDE UNIT: MUZ—FHO6NA � MASTER BEDROOM COVERED PATIO i W5 MASTER SUITE , '' ROOM ID(2) ' 0 5 , W3 wa 386 S.F. •i N o DINING ROOM KITGIIEN FAMILY ROOM , 12'-8' 3 D2 ws EXISTING GOODMAN �ATf1 � WIG 3—TON HVAC SPLIT ' SYSTEM MAIN ; ' ROOM ID (1) ' 919 S.F. ,o .LIVING ROOM >3Am a O GARAGE 1 D1 � O t3EDRO0M 2 We FRONT PO�RGtIIi 10 ' ws w9 , L� 13'-0" 22'-0° HTq / CLq LOAD SCHEDULE BY ROOM ROOM/SPACE AREA HEATING COOLING (Sq. ft.) (Btuh) (Btuh) MAIN: t919 24,354 SENSIBLE: (WHOLE HOUSE NOT 27,565 LATENT: INCLUDING MASTER SUITE) 2,402 TOTAL: 29,967 MASTER SUITE: ties 6,sss SENSIBLE: (MASTER BEDROOM, BATH 7,231 LATENT; & W.I.C.) sss TOTAL: 7,896