HomeMy WebLinkAboutProduct Review; EX 2001 Inside Access Light Fixture■ IS -Gauge Steel Construction,
Sealed & Gasketed
■ .White Powder Coating Finish'It Front Ac'cess Fixture.
■. ETL.Listed
Proper lighting allows.for a better spray environment and
is critical -to achieve a. high quality finish. Giving bright, full booth
i. illumination, Col -Met offers the.Series,EZ 2b01 Light Fixture, which is a
slim 2 7/16"product suited forany s ray boothThese lights are va or
and dust proof with ETL listings of.Class.l, Division.2 and Class 2; Division
2. The series cornes in a 4-lamp configuration of T8/32W and are powder.
coated white for increased light output.
CONTRACTOR REQUIREMENT PACKAGE
12`W x 12'H x 121 Custom Open Face
Booth.
W/(1) 2HP EXHAUST FAN-
Ana"AAFA'r
12'W x 12'H x 121 Custom Open Face Booth,- Exhaust Only 2/28/2020
**CONTRACTORS MUST VERIFY COMPLIANCE OF LOCAL CODES WITHIN THE JURISDICTION OF THE INSTALLATION SITE**
SECTION Q - 12'W x 12'H x 121 Custom Open Face Booth
ELECTRICAL REQUIREMENTS Page 1q
NOTE: The information provided in this documentation is for PRELIMINARY BIDDING AND PLANNING PURPOSES ONLY.
i
BoothRequirements:.
(1) Standard 2hp: Motor-.208v/20amp, 230v/20amp or 460v/10amp. 3 phase
service. Lights - .(1) 120v- 20amp single-phase circuits standard or (:1) 277v-
10amp single phase circuits optional.
The voltage for the lights and ,motors (as well as horsepower.) must .be
specified upon ordering the. equipment. Changing. the voltage in. the
field will require the purchase of different anal/or additional
components.. The purchase of an on
sight listing of the. Paint Booth may also 'be required..
I. All electrical should: run through .a disconnect panel .per _NEC (National
Electrical Code) before entering the Garmat Control Panel:
II. Connectpower for (1). 2hp 208/230/460v, 3-p.h6se 60,hz motor circuit (see
page 1q-1 item 1.).
III. Connect power to 120/277v lighting circuit (see page lq=1 item 1).
I
IV. Connect lighting circuits from Main Control Panel to. junction. boxes on- Spray
Booth Cabin.
V. Connect to Suppress System normally closed switch (mounted by fire
suppression contractor) from`termi.nals_ marked "jumper" in control .panel.
.(see. page 1q-1 item 2) Jumper. must be removed prior.to connection.
VI. DO NOT install electrical to obstruct any access doors and _panels,. Must be
at Feast 3' from booth door openings. Per NFPA 70 (NEC); current, 4.3.
VII. The front of the Control panel must be 3'=0" from any opening on the spray
booth, 3'-6" .from -any obstruction and 4'' from another control panel. Per
.National Electrical Code (NEC).
An141?1114T
12'W x 12'H x 121.Custom, Open, Face Booth - Exhaust"Only 2/28/2020
**CONTRACTORS MUST VERIFY COMPLIANCE OF LOCAL CODES WITHIN THE JURISDICTION OF THE INSTALLATION SITE**
SECTION Q — 12'W x 12'H. x 121 Custom Open Face Booth
ELECTRICAL REQUIREMENTS Control Panel.- Page 1q-1
NOTE: The, information.provided in this documentation is for PRELIMINARY BIDDING AND PLANNING PURPOSES ONLY.
EM
O
OFF/ON
SPRAY
ON
Pot
0
OFF]LIGHTS
ems..
�TAf�
-�
V
���
CONTROLPANEL
1. Power Connection Block -- Motor Circuit
2. Jumper for the Fire Suppression System
3. Grounding Bar
12'W x 12'H x 12'L Custom Open Face Booth - Exhaust Only 629 20
CONTRACTORS. MUST VERIFY COMPLIANCE OF LOCAL CODES WITHIN THE JURISDICTION OF THE INSTALLAI
Gi'
CONTRACTOR REQUIREMENT PACKAGE
SM x TH x ..51 Custom Open. Faco Booth
W/(1) 1.5.HP EXHAUST FAN
�aour'Copy
8'W.x TH x 51 Custom Open Face Booth - Exhaust Only 2/28/2020
**CONTRACTORS MUST VERIFY COMPLIANCE OF LOCAL CODES WITHIN THE JURISDICTION OF THE INSTALLATION SITE"
SECTIOAV Q — 8'W x 7'H x 51 Custom Open Face Booth
ELECTRICAL REQUIREMENTS. Page iq
NOTE: The information provided' in this documentation is for PRELIMINARY BIDDING AND PLANNING PURPOSES ONLY.
Booth Requirements:
(1) Standard 1.5hp Motor - 208v/20amp, 23.0V/20amp or 46.0v/.10amp 3
phase service. Lights - (1) 120V- 20arnp single=phase circuits standard or (1)
277v- 10amp single phase circuits optional.
The, voltage for the lights. and motors (as well as'horsepower). must be
specified upon ordering the equipment., Changing, the` voltage in the
field will require the purchase of different. and/or additional
components. The purchase of an on
sight Fisting of the Paint Booth may also be required.
I. All electrical should run through a disconnectpanel per NEC (National
Electrical Code) before entering the _Garmat Contro[.Panel..
II. Connect power for (1.) 1'.5hp 208/230/460v., 3-phase 60hz motor circuit (see
page iq-1 item .1)..
III. Connect power to 120/277V lighting circuit (see page 1q-1'item 1).
W. Connect lighting circuits, from Main Control. Panel to. junction boxes on Spray
Booth Cabin.
V. Connect to Suppression. System normally closed switch (mounted by fire
�suppressio.n contractor) from terminals -marked "jumper" -in control panel
(see page i.q4 item 2). Jumper must be removed prior to connection..
VI, DO NOT install electrical to obstruct: any access doors and panels. Must be
at least 3' from booth door- openings. Per NFPA 70 (NEC), current, 4.3.
VII. The front'of the Control panel must be 3'-0-" from any opening on the spray
booth, 3'-6" from any 'obstru.ction and 4' from another control panel.. Per
National Electrical Code (NEC)...
�i41?ll�l4%
8'W x TH x 51 Custom Open Face Booth -.Exhaust Only 2i28/2020
**CONTRACTORS MUST VERIFY COMPLIANCE OF LOCAL CODES' WITHIN THE JURISDICTION OF THE INSTALLATION SITE**
SECTION Q — 8'W x TH x: 51 Custom Open Face Booth
ELECTRICAL REQUIREMENTS Control. Panel Page lq-1
NOTE: The information provided in this documentation is for PRELIMINARY BIDDING AND PLANNING PURPOSES ONLY.
EM
7-
OFF/ON'
O
SPRAY
Pot
ON O
OFF LIGHTS
CONTROL PANEL
1. Power Connection Block -- Motor Circuit
2. Jumper for the Fire Suppression System
3. Grounding Bar .
AnfWI�I�I%
8'W x 7'H x 51 Custom Open Face Booth - Exhaust Only. 2/28/2020
**CONTRACTORS MUST VERIFY COMPLIANCE OF LOCAL CODES WITHIN THE JURISDICTION OF THE INSTALLATION SITE**