HomeMy WebLinkAboutAPPROVED 26 GA Nailstip Standing Seam Product . . Fabricators,
2160 SW Poma Drive
Palm City, FL 34990
772)872-8034
Compliant with Florida Building Code 2017 (61h ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or
Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.)
Rib Height 1"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1: #10 x 1" (mina Pancake Head Wood Screw to penetrate 3/16" (mina thru
bottom of support.
Adhesive/Sealant : Bostik 915' Chem-Chalk one component, polyurethane adhesive with
3/16" continuous bead application along base of male rib vertical flange at each panel
seam.
Underlayment: To be compliant with FBC Sec 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
Install Details: Table A Allowable Loads METHOD 1 METHOD 2
DESIGN PRESSURE* -86 PSF Main field —F-97.25 PSF Perimeter
FASTENER SPACING 6" O.C. T 6" O.C.
SEAM ADHESIVE Not required 3/16" continuous bead
(see details
Reference Data: ARCHITECTURAL TESTING, INC.TST ID#: 1527
UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 
EQUIVALENCY: UL1897-04 is equivalent to Test Standard UL1897-12. *Design Pressure margin of safety 2:1
Certificate of Independence:
Locke Bowden, P.E.does not have, not will acquire a financial iWpM5f41vq9y company manufacturing or distributing products
under this evaluation. `��`�LD• Br�� "�,,�
Locke Bowden, P.E. is not owned,operated,or controlled' y y mph ,pSanY%cturer,or distributing products under this
report. pY��
seal
STATE OF
7. a
r♦• !OR0D '.• ,'r .
'< <:ONAL
Limitations:
1.Underlayment to be compliance with current Florida Building Code(FBC)2017 6th ed..
2.Minimum slope to be compliant with Florida Building Code 2017 6th ed.,and per with Manufacturer's installation reference.
3.Products are compliant for State of Florida product approval per Rule 61 G20-3.Compliance Method: 1-D
4.Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5.Fire classification is not part of this acceptance.Shear diaphragm values are outside this report.
6.Support framing in compliance w/FBC 2017 6th ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7.This report does not imply warranty, installation, recommended product use outside of this report.
FL 17022.5 1.0 Nail Strip (26GA Steel), 16"Wide Roof Panel - Details
16"
3/411
Panel Profile
16" o.c.
Deck:
- 15/32"or greater Plywood,or
-Wood plank
Integral Snap Lock
For METHOD 2:
Apply 3/16"Bead Bostik 915TM Sealant
Continuous Along Male Rib Vertical Flange
Fastener
#10 x 1"Min. per Table"A"
Pancake Head Wood Screw
(Typical Fastening Pattern Across Width)
FL 17022.5 1.0 Nail Strip (26GA Steel), 16"Wide Roof Panel - Details
Fastener
#10 x 1" Min. per Table"A"
Pancake Head Wood Screw
1" Nail Strip Roof Panel
.Q'
tea,
�o
Q
Seam Adhesive Application:
Deck: For Method 2
- 15/32"or greater Plywood, or Apply 3/16" Bead Bostik 915TM Sealant
-Wood plank Continuous Along Male Rib Vertical Flange
(Refer to Table"A")
Isometric View