Loading...
HomeMy WebLinkAboutTruss Engineeringm r - m r- 0 OD® 0 Z Cl) m `-O 0 0 m c Z 0 C- M 0 M z 0 0 T zU1 Cf) •ZD7® n UD 1,10 OD m r- C: Fn- z z G) C/) 0 m m Z > m r - m A-1 ROOF TRUSSES A FLORIDA CORPORATION Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 These truss designs rely on lumber values established by others. Site Information: Customer Info: RENAR DEVELOPMENT CO. Project Name: MORNINGSIDE Lot/Block: 114 Model: CAYMAN 1560 Address: 324 PALM BREEZE DRIVE Subdivision: City: County: St Lucie A-1 Roof Trusses 4451 St Lucie Blvd Fort Pierce, FL 34946 State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC 2017 RES / TPI 2014 Design Program: Alpine Engineered Products Wind Code: ASCE 7-10 Wind Speed: 160 Roof Load: 37.0 psf Floor Load: 0.0 psf This package includes 45 individual, dated Truss Design Drawings and 16 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. No. Seq # Truss Name Date No. Seq # Truss Name Date No. Seq # Truss Name Date 1 2505 A01 7/13/20 13 3361 A13 7/13/20 25 2590 HP 7/13/20 j 2 3376 A02 7/13/20 14 3466 B01 7/13/20 26 2569 HPA 7/13/20 3 3391 A03 7/13/20 15 3470 B02 7/13/20 27 3463 HJ713 7/13/20 4 3334 A04 7/13/20 16 2530 B03 7/13/20 28 2499 HJ7P 7/13/20 I5 3431 A05 7/13/20 17 2572 C01 7/13/20 29 2593 J1 7/13/20 6 3421 A06 7/13/20 18 3407 CO2 7/13/20 30 2487 J1P 7/13/20 7 3414 A07 7/13/20 19 3401 CO3 7/13/20 31 2596 J3 7/13/20 8 3365 A—_,__...,._,._ 08 7/13/20 20 12514 E01 7/13/201 32 13434 J3A 7/13/20 9 3398 A09 7/13/20 21 2587 E02 7/13/20 33 2490 J3P 7/13/20 10 3326 A10 7/13/20 22 2511 E03 7/13/20 34 2599 J5 7/13/20 11 3315 A11 7/13/20 23 3456 E04 7/13/20 35 2536 J5A 7/13/20 12 3322 1 Al2 7/13/20 24 2533 GE01 7/13/20 136 3437 J5B 7/13/20 he truss drawing(s) referenced have been prepared bywpine Engineered Products, Inc. under mydirect supervision based on the parameters provided byAv 1 hoof I russes, Ltd. Truss Design Engineer's Name: Rama Pranav Kristam My license renewal date for the state of Florida is February 28,2021. NOTE: The seal on these drawings indicate acceptance of professional engineering msponsibility solely forthe truss components shown. The suitability and use of components forany particubrbuikling is the responsibility ofthe building designer, perANSVTPI-1 Sec. ?- The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction documents (also referred to at times as'Structural Engineering Documents') provided bythe Bulling Designer indicating the nature and characterofthe work The design criteria therein have been transferred to Rama Pranav Kristam PE by [Al Roof Trusses or specific location]. These TDDs (also referred to at times as'Structural Delegated' Engineering Documents') are specialty structu ral component designs and may be part of the project's deferred or phased submittals. As a Truss Design Engineer(i.e., Specialty Engineer), the seal here and on the TDD represents an acceptance of professional engineering responsibilityforthe design of the single Truss depicted on the TDD only. The Building Designeris responsible forand shall coordinate and review the TDDs for compatibility with theirwritten engineering requirements. Please review all TDDs and all related notes. Page 1 of 2 Rama Pranav Kristam, P.E. 4451 St Lucie Blvd. Suite 201 Fort Pierce, FL 34946 Rama Pranav Kdstam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 r =_A-1 ROOF TRUE A FLORIDA CORPORATION RE: Job ARMSCM 1 560B 1 L No. Seq # Truss Name Date 37 2493 J5P 7/13/20 38 2539 J6 7113/20 39 2602 J7 7/13/20 40 3368 J7C 7/13/20 41 2496 J7P 7/13/20 42 2584 VM01 7/13/20 43 2581 VM02 7/13/20 44 2578 VM03 7/13/20 I45 2575 VM04 7/13/20 46 STDL01 STD. DETAIL 7/13/20 47 STDL02 STD. DETAIL 7/13/20 48 STDL03 STD. DETAIL 7/13/20 49 STDL04 STD. DETAIL 7/13/20 50 STDL05 STD. DETAIL 7/13/20 51 STDL06 STD. DETAIL 7/13/20 52 STDL07 STD. DETAIL 7/13/20 53 STDL08 STD. DETAIL 7/13/20 54 STDL09 STD. DETAIL 7/13/20 55 STDL10 STD. DETAIL 7/13/20 156 STDL11 STD. DETAIL 7/13/20 r— 157 STDL12 — STD. DETAIL 7/13/20 58 STDL13 STD. DETAIL 7/13/20 59 STDL14 STD. DETAIL 7/13/20 60 STDL15 STD. DETAIL 7/13/20 61 STDL16 STD. DETAIL 7/13/20 Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 These truss designs rely on lumber values established by others. Rama Pranav Kristam, P.E. # 88906 Page 2 of 2 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 �joo truss i russ I ype dry my U//13/LULU {IARM�CM1560BlL (A01 HIPS ( 1 I 1 2505 254# 184# 1844 18 184# 184# 1844 186# 186# 186# 1864 186# 254# F-7'0"62'0"6 i 2, i 2, i 2, i 2, it'11'4 2, i 2, i 2 i 2, 20"6 7'0"6 �- 7' i24' 7' '=6X8=3X4 =3X10 T2 =3X6 =4X6 W4X6 T2 12._ O D -- E 1111.5X3 FG H I m.111, M _11. -,qq Wind Criteria TCLL: 20.00 M. I .1110 TCDL: 10.00 M V 1: Enclosure: Closed BCDL: 7.00 Risk Category: 11 T - S EXP: B Kzt: NA IaI V TU � =3X4 IIID Y"I . 5X61111.5X3 5X8 P SEAT PLATE REQ. SEAT PLATE REQ. 21'8" 8'4"6 11 r 38' T K=3X6(At) ONm4X4 M. W3X6(`*) 1112X4 SEAT PLATE REQ. 16'4' 18'7"9 1 5� 442# 10 107# 10 107# 10 107# 1111 111# 111# 111# 114 442# Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: 11 T - S EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 R -P C&C Dist a: 3.80 ft 1 - N Loc. from endwall: NA S - E GCpi: 0.18 N - J Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 :T2 2x4 SP M-30: Bot chord 2x4 SP #2 :B2 2x4 SP M-30: Webs 2x4 SP #3 Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE Bracing (a) Continuous lateral restraint equally spaced on member Special Loads -----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 62 plf at -1.46 to 62 plf at 7.00 TC: From 31 plf at 7.00 to 31 plf at 31.00 TC: From 62 plf at 31.00 to 62 plf at 39.46 BC: From 14 pif at 0.00 to 14 plf at 7.03 BC: From 7 pif at 7.03 to 7 pif at 30.97 BC: From 14 pif at 30.97 to 14 plf at 38.00 TC: 254 Ib Conc. Load at 7.03,30.97 TC: 184 Ib Conc. Load at 9.06,11.06,13.06,15.06 17.06,19.00 TC: 186 Ib Conc. Load at 20.94,22.94,24.94,26.94 28.94 BC: 442 Ib Conc. Load at 7.03,30.97 BC: 107 Ib Conc. Load at 9.06,11.06,13.06,15.06 17.06,19.00 BC: 111 Ib Conc. Load at 20.94,22.94,24.94,26.94 28.94 Defl/CSI Criteria PP Deflection in loc L/defl L/ VERT(LL): 0.121 D 999 3 ktRT(CL): 0.228 D 999 2 HORZ(LL): 0.055 M - HORZ(TL): 0.103 M - Creep Factor: 2.0 Max TC CSI: 0.740 Max BC CSI: 0.999 Max Web CSI: 0.997 Wgt: 204.4 lbs 7# 7# 7# VIEW Ver: 19.01.00A.0618.16 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 7.00 31.00 BC 69 0.15 8.22 BC 76 8.26 19.51 BC 75 19.51 37.85 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Plating Notes (**) 1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Wind Wind loads and reactions based on MWFRS. Right bottom chord exposed to wind. ♦ Maximum Reactions (Ibs) # Gravity Non -Gravity 60 Loc R+ / R- / Rh / Rw / U / RL 40 B 1441 J- !- /- /631 /- - P 4556 /- /- /- /2574 /- K 844 /- /- /- /520 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.7 P Brg Width = 8.0 Min Req = 5.4 K Brg Width = 8.0 Min Req = 1.5 Bearings B, P, & K are a rigid surface. Bearings B, P, & K require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 39 -23 G - H 1294 -774 B - C 1092 -2457 H -1 2352 -1268 C - D 1269 -2841 I - J 292 -12 D - E 749 -1890 J - K 862 -1189 E -F 1292 -776 K -L 39 -23 F - G 1292 -776 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - V 2112 -924 P-0 0 -374 V - U 85 -53 O - N 0 -374 T - S 2873 -1285 N - M 1010 -737 S - Q 1817 -731 M - K 986 -723 R -P 19 -52 1 - N 1092 -632 S - E Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - V 656 -1125 Q - R 45 -29 C - T 1923 -932 Q - H 1704 -772 V - T 2616 -1105 Q - P 1297 -2386 T -U 0 -144 H -P 899 -1715 T- D 133 0 P-1 1767 -2714 D - S 607 -1125 1 - N 1092 -632 S - E 790 -192 N - J 724 -1341 E - Q 1682 -3416 M - J 598 -350 G - Q 365 -499 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -7. Convrinht n 20M A-1 Roof Tnrxsa - Renrnduotion of this dnnimant in anv form. is nmhihifad without tha wnttan nannissinn of A-7 Rnnf Tnicsas ARMSCM1560B1L IA02 HIPS 3376 1 Loading Criteria (ps0 Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 oE5X6 =3X6 Enclosure: Closed BCDL: 7.00 D E 12 1111.5X4 C III 1.5X3 FG H 1 - J Des Ld: 37.00 T 6 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf m o MWFRS Parallel Dist: 0 to h/2 (a) C&C Dist a: 3.80 ft Wgt: 207.2 lbs v �i -199 =6X6 V11 VIEW Ver: 19.01.00A.0618.16 Bearings B, P, & P require a seat plate. T3 in K=3X6(A1) �-3XA(A1)B 4X6(R) S Q 157 -251 1 286 TU 1111.5 3 P=3X8 O 1111.5X3 D - E 272 -214 J - K 244 -354 -3X6 SEAT PLATE REQ, SEAT PLATE REQ. SEAT PLATE REQ. Z7 21'8" 164" P"91----- 84"6 -{' 11' 187"9 11'5„A Loading Criteria (ps0 Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II HORZ(TL): 0.108 Q EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 Max Web CSI: 0.995 C&C Dist a: 3.80 ft Wgt: 207.2 lbs Loc. from endwall: not in 9.00 -199 GCpi: 0.18 VIEW Ver: 19.01.00A.0618.16 Bearings B, P, & P require a seat plate. Wind Duration: 1.60 Lumber Top chord 2x4 SP #2:T3 2x4 SP 2400f-2.OE: Bot chord 2x4 SP #2 Webs 2x4 SP #3 :W1 2x4 SP M-30: Code / Misc Criteria Code: FEC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 3X4 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 9.00 29.00 BC 97 0.15 8.21 BC 120 8.21 19.51 BC 75 19.51 37.85 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Negative reaction(s) of -182# MAX. from a non -wind load case requires uplift connection. See Maximum Reactions. 38' Defl/CSI Criteria ♦ Maximum Reactions (lbs), or *=PLF PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): 0.087 C 999 360 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): 0.161 C 999 240 B 682 !- /- /417 /273 /171 HORZ(LL): 0.057 Q - - P 2031 /- /- /1059 /742 /- HORZ(TL): 0.108 Q K* 45 /-11 /- /26 /11 /- Creep Factor: 2.0 O /-112 Max TC CSI: 0.655 N /-262 Max BC CSI: 0.710 Wind reactions based on MWFRS 473 B Brg Width = 8.0 Min Req = 1.5 Max Web CSI: 0.995 P Brg Width = 8.0 Min Req = 2.4 Wgt: 207.2 lbs K Brg Width = 192 Min Req = - -199 Bearings B, P, & P are a rigid surface. VIEW Ver: 19.01.00A.0618.16 Bearings B, P, & P require a seat plate. O - J Maximum Top Chord Forces Per Ply (Ibs) -789 Chords Tens.Comp. Chords Tens. Comp. 157 -251 A- B 39 0 G- H 829 -153 286 B - C 414 -782 H - 1 1154 -274 Q -R C - D 681 -926 I - J 557 -86 D - E 272 -214 J - K 244 -354 E- F 830 -154 K- L 39 0 F - G 830 -154 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - U 612 -193 P-0 295 -598 T - S 572 -119 O - N 206 -157 S - Q 188 -43 N - M 206 -157 R -P 4 -18 M -K 201 -167 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. Webs Tens. Comp C - T 525 -580 Q - H 651 -238 T -U 130 0 Q -P 602 -1194 T - D 713 -503 H - P 294 -695 D - S 202 -460 P-1 473 -1061 S - E 398 -67 1 - O 644 -199 E - Q 506 -1228 O - J 395 -789 G - Q 157 -251 M - J 286 -153 Q -R 12 -5 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (Le, Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. Co-nnint t7 Mile AA Roof Tntaan_s - Renrndnrtinn of this donlmnnlin anv fnnni nrnhihitad wilhout tha wdtlan n-ission of A-1 Roof Tni-% ARM,5CM1560B1L I A03 r 11' HIPS 16' 1., 1, .... %6X8(R) =5X12 01111.5X3 =8X10 D E T2 F G 11' 3391 -3} SEAT PLATE REQ. 3X4=4X6 =6X10 1111.5X4 38' 1'S"9 f -j- 21'5"3 Loading Criteria (psf) Wind Criteria Code / Misc Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES TCDL: 10.00 Speed: 160 mph TPI Std: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) O - E EXP: B Kzt: NA Plate Type(s): Des Ld: 37.00 Mean Height: 25.00 ft WAVE, HS NCBCLL: 10.00 TCDL: 5.0 psf 291 Load Duration: 1.25 BCDL: 4.2 psf 7027 -2537 Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.80 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP 2400f-2.OE :T2 2x6 SP 2400f -2.0E: Bot chord 2x4 SP 2400f -2.0E Webs 2x4 SP #3:W4 2x4 SP 2400f-2.OE: :W5, W6 2x4 SP #2: :W7 2x4 SP M-30: Bracing (a) Continuous lateral restraint equally spaced on member Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 11.00 27.00 BC 109 0.15 21.29 BC 83 21.29 37.85 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.798 M 566 36 VERT(CL): 1.508 M 300 24 HORZ(LL): 0.428 K - - HORZ(TL): 0.808 K Creep Factor: 2.0 Max TC CSI: 0.846 Max BC CSI: 0.995 Max Web CSI: 0.851 Wgt: 210.0 lbs VIEW Ver: 19.01.00A.0618.16 SEAT PLATE REQ. 166"13 11'5"9 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw /U / RL B 1540 /- /- /865 /563 /199 1 1544 /- /- /860 /566 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 1 Brg Width = 8.0 Min Req = 1.5 Bearings B & I are a rigid surface. Bearings B & I require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A- B 39 0 F- G 3711 -9403 B - C 1203 -2699 G - H 1780 -4397 C - D 1076 -2359 H -1 2006 -4705 D- E 1205 -2459 I- J 39 0 E -F 3673 -9304 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - Q 2348 -928 M - L 4055 -1422 Q - P 2051 -691 L - K 4036 -1423 P-0 2051 -691 K - I 4228 -1712 O -N 41 -15 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C - Q 270 -338 F - M 137 -33 D- Q 387 -45 M- N 78 0 D-0 593 -300 M - G 5652 -2104 O - E 970 -2377 K - G 248 -1 O -M 3190-1145 K -H 291 -210 E - M 7027 -2537 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineeiin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. Cnnvdnht 0 2016 A-1 Rnnf Tme­s- Renmduntinn of thio rin-mnnt in anv forth. is nmhihited without the written non m.inn of A-1 Rnnf T.,eeas. ARMSCM1560B1 L A04 I HIPS r 11 (1' I V v 3334 �T E M M 1 =37 r 12'8"-j 12'8" -1 12'8" -1 =5X6 =5X8 1111.5X3 =5X10 D E F G 1111.5X3 =3X6=3X4 =7X8 1111.5X3 SEAT PLATE REQ. 1'S"9 -} 21'5"3 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: 11 VERT(CL): 1.080 F 419 240 EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h B Brg Width = 8.0 Min Req = 1.8 C&C Dist a: 3.80 ft Max TC CSI: 0.641 Loc. from endwall: not in 9.00 -438 GCpi: 0.18 Bearings B & I are a rigid surface. Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 :T1 2x4 SP #2: Bot chord 2x4 SP #2 :B3 2x4 SP M-30: :B4 2x4 SP 2400f-2.OE: Webs 2x4 SP #3:W5, W6, W7 2x4 SP #2 38' SEAT PLATE REQ. 16'6"13 i 1'5"9 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/deft L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.572 F 791 360 Loc R+ / R- / Rh / Rw /U / RL Rep Factors Used: Yes VERT(CL): 1.080 F 419 240 B 1540 /- /- /872 /416 /223 FT/RT:10(0)/10(10) HORZ(LL): 0.333 K - - 1 1544 /- !- /867 /419 /- Plate Type(s): HORZ(TL): 0.629 K - - Wind reactions based on MWFRS WAVE, HS Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.8 893 -2340 Max TC CSI: 0.641 1 Brg Width = 8.0 Min Req = 1.5 -438 Max BC CSI: 0.995 Bearings B & I are a rigid surface. H - K Max Web CSI: 0.988 Bearings B & I require a seat plate. E - N 4375 -1479 Maximum Top Chord Forces Per Ply (Ibs) Wgt:215.6lbs Chords Tens.Comp. Chords Tens, Comp. VIEW Ver: 19.01.00A.0618.16 A- B 39 0 F - G 2401 -6060 B - C 1134 -2704 G - H 1676 -4145 C - D 1033 -2219 H - 1 1871 -4674 D- E 1067 -2109 1- J 39 0 E - F 2389 -6027 Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 12.67 25.33 BC 94 0.15 21.29 BC 91 21.29 37.85 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - S 2341 -861 N - M 3795 -1278 S - R 2339 -863 M - L 4223 -1596 R - Q 2339 -863 L - K 4209 -1600 Q - P 1906 -614 K - I 4188 -1583 P -O 23 -8 217 -41 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp S -C 209 0 F -N 146 -154 C- Q 285 -497 N-0 59 0 D - Q 363 -101 N - G 2747 -967 D -P 359 -179 M -G 217 -41 P - E 893 -2340 M - H 320 -438 P - N 3001 -1006 H - K 119 -52 E - N 4375 -1479 `*WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. (;nnvnnht n 2n1e A-1 in anv i'am in nrnhihitnd vnlhnmt the wnttnn nannic inn of A-1 Rnnf Tmc 1IARM$CM1560B1L IA05 IHIPSyPc 1y (1y I V"iJfLULU MT V N 1 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " i 14'8" 'i- 8'8" 'I 14,8„ 3431 =bylb llll.bX4 SEAT PLATE REQ. PA T 11'10"12 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.80 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 :T3 2x4 SP 2400f-2.OE: :T4, T5 2x4 SP M-30: Bot chord 2x4 SP #2:133 2x4 SP M-30: :B4 2x4 SP 2400f -2.0E: Webs 2x4 SP #3:W3 2x4 SP #2: Code / Misc Criteria Code: FBC2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Plating Notes (1) - plates so marked were sized using 0% Fabrication Tolerance, 10 degrees Rotational Tolerance, and/or zero Positioning Tolerance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 14.67 23.33 BC 95 0.15 11.72 BC 89 11.72 19.00 BC 93 19.00 37.85 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. 7'1"4 38' SEAT PLATE REQ. Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/deft L/# Gravity Non -Gravity VERT(LL): 0.513 O 881 360 Loc R+ ! R- / Rh / Rw /U / RL VERT(CL): 0.971 O 466 240 B 1542 /- /- /879 /412 /252 HORZ(LL): 0.346 L - - J 1545 /- /- /873 /415 /- HORZ(TL): 0.654 L Wind reactions based on MWFRS Creep Factor: 2.0 B Erg Width = 8.0 Min Req = 1.8 Max TC CSI: 0.976 J Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 1.000 Bearings B & J are a rigid surface. Max Web CSI: 0.713 Bearings B & J require a seat plate. P -Q Maximum Top Chord Forces Per Ply (Ibs) Wgt: 193.2 lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.0618.16 A - B 39 0 F - G 1793 -4765 952 -452 B - C 1100 -2725 G - H 1539 -3866 C - D 1751 -4560 H -1 1513 -3913 D - E 1763 -4475 1 - J 1809 -4690 E- F 1868 -4517 J- K 39 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - R 2363 -833 N - M 4228 -1519 R - Q 26 -11 M - L 4225 -1532 P-0 3582 -1073 L - J 4204 -1518 O - N 3536 -1105 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp, Webs Tens. Comp C-R 521 -1241 F-0 1516 -412 C - P 1664 -468 O - G 1592 -420 R - P 2656 -933 N - G 366 -97 E - P 195 -193 N - 1 407 -702 P -Q 78 0 1-L 185 0 P - F 952 -452 `*WARNING'" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the content of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. C:n.vnnht,7 201E A-1 Rnnf Tmscee - R.nmd-lion of thi., do-ment in anv f- ix nmhihited withnut the wn0nn nen mM.n of A-1 Rnnf Tn,cae.,. ARMSCM1560B1 L A06 HIPS 16'8" 4'8" ---}-- 5X6 1111.5X3 5X6 F G H 1 1 ( 3421 V 16'8" if SEAT PLATE REQ. m (F1) SEAT PLATE REO. 38' P.9-{- 11'10"12 7'1"4 + 19' 1 5 9{ Loading Criteria (psD Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II R - P EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h P- Q C&C Dist a: 3.80 ft M- J Loc. from endwall: not in 9.00 -456 GCpi: 0.18 1262 -645 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 :T4 2x4 SP 2400f-2.OE :T5 2x4 SP M-30: Bot chord 2x4 SP M-30 :B1 2x4 SP #2: :B4 2x4 SP 2400f-2.OE: Webs 2x4 SP #3:W3 2x4 SP #2: Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 16.67 21.33 BC 95 0.15 11.72 BC 90 11.72 19.00 BC 104 19.00 37.85 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Defl/CSI Criteria PP Deflection in loc L/deft L/# VERT(LL): 0.459 O 986 36 VERT(CL): 0.867 O 521 24 HORZ(LL): 0.309 M - HORZ(TL): 0.584 M - Creep Factor: 2.0 Max TC CSI: 0.843 Max BC CSI: 0.996 Max Web CSI: 0.772 Wgt: 200.2 Ibs VIEW Ver: 19.01.00A.0618.16 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw IU / RL B 1542 /- /- /880 /409 /280 K 1545 !- /- /874 /413 /- Wind reactions based on MWFRS B Erg Width = 8.0 Min Req = 1.8 K Brg Width = 8.0 Min Req = 1.5 Bearings B & K are a rigid surface. Bearings B & K require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-13 39 0 G- H 1381 -3592 B - C 1065 -2721 H -1 1925 -4620 C - D 1685 -4510 I - J 1889 -4643 D - E 1696 -4425 J - K 1753 -4714 E - F 1847 -4523 K - L 39 0 F - G 1381 -3591 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - R 2359 -801 O - N 3225 -905 R - Q 29 -10 N - M 3206 -915 P-0 3219 -844 M - K 4228 -1461 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C-R 495 -1217 F-0 901 -215 C - P 1630 -447 G-0 95 -54 R - P 2639 -894 0-H 960 -181 E - P 277 -328 H - M 1269 -639 P- Q 78 0 M- J 379 -456 P - F 1262 -645 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field If 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. Cnnvrioht n 201E A-1 Ronf Tri S ., - Rnnrnnnrtion of this damimont. in Env form. in nmhihitoA without the wntton normissinn of A-7 Roof Tnicsn.< I ARMSCM1560131 L M co ~ N IV N =3) A07 HIPS .yN- 18'8" Wfy rry I V//IJ/LVLV 1 1 18'8" 3414 SEAT PLATE REQ. li 5"9I 11'10"12 Loading Criteria (psf) Wind Criteria TOLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00Risk Category: II Wind reactions based on MWFRS EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h Maximum Top Chord Forces Per Ply (Ibs) C&C Dist a: 3.80 ft Chords Tens.Comp. Chords Tens. Comp. Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2:T3, T4 2x4 SP M-30 Bot chord 2x4 SP M-30:131 2x4 SP #2: :134 2x4 SP 2400f -2.0E: Webs 2x4 SP #3:W3 2x4 SP #2: Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes (") 1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 96 0.15 11.75 BC 89 11.79 19.00 BC 101 19.00 37.85 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. TV4 38' SEAT PLATE REQ. Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): 0.467 N 969 360 Loc R+ / R- / Rh / Rw /U / RL VERT(CL): 0.883 N 512 240 B 1542 !- /- /869 /400 /310 HORZ(LL): 0.325 L - - J 1545 /- /- /864 /403 /- HORZ(TL): 0.615 L Wind reactions based on MWFRS Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.8 Max TC CSI: 0.923 J Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.985 Bearings B & J are a rigid surface. Max Web CSI: 0.909 Bearings B & J require a seat plate. O - E Maximum Top Chord Forces Per Ply (Ibs) Wgt: 191.8 Ibs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.0618.16 A- B 39 0 F - G 1057 -3228 B - C 980 -2716 G - H 1466 -4269 C - D 1516 -4517 H - 1 1449 -4346 D - E 1529 -4432 1 - J 1650 -4760 E- F 1072 -3241 J- K 39 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - Q 2353 -717 N - M 3723 -1036 Q- P 29 -9 M- L 3704 -1044 O - N 4105 -1120 L - J 4280 -1383 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C - Q 448 -1201 E - N 624 -1203 C-0 1649 -380 N - G 496 -814 Q-0 2626 -798 F - N 2385 -671 O -P 80 0 G -L 517 -95 O - E 432 -90 L - I 316 -341 `"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. (:nnvdnht nc 2n16 A-1 Rnnf Tnicaas – RnnrM—dinn of Ihi� dnnnmanf. m anv form. is nmhi fled wifhnnt fhe wnffen nermiccion of A-1 Rmf T- ARMSCM1560B1L A08 I COMN, 12r ( '1, .,,,.r.... 3365 fl i 19' F=5X6 19, -1 SEAT PLATE REQ. 1'591 " E- 1--- 1110"12 + 7'1"4 Loading Criteria (psf) Wind Criteria TCLL 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II Wind reactions based on MWFRS EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h Maximum Top Chord Forces Per Ply (Ibs) C&C Dist a: 3.80 ft Chords Tens.Comp. Chords Tens. Comp. Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2:T3, T4 2x4 SP M-30 Bot chord 2x4 SP M-30 :B1 2x4 SP #2: :B4 2x4 SP 2400f -2.0E: Webs 2x4 SP #3 :W3 2x4 SP #2: Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes (1) - plates so marked were sized using 0% Fabrication Tolerance, 10 degrees Rotational Tolerance, and/or zero Positioning Tolerance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 95 0.15 11.75 BC 89 11.79 19.00 BC 100 19.00 37.85 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. 38' SEAT PLATE REQ. 19' 11 5 9I Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/deft L/# Gravity Non -Gravity VERT(LL): 0.469 N 963 360 Loc R+ / R- ! Rh / Rw /U / RL VERT(CL): 0.888 N 509 240 B 1542 /- /- /876 /407 /314 HORZ(LL): 0.328 L - - J 1545 /- /- /870 /410 /- HORZ(TL): 0.620 L Wind reactions based on MWFRS Creep Factor: 2.0 B Erg Width = 8.0 Min Req = 1.8 Max TC CSI: 0.923 J Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.993 Bearings B & J are a rigid surface. Max Web CSI: 0.909 Bearings B & J require a seat plate. O - E Maximum Top Chord Forces Per Ply (Ibs) Wgt: 193.2 Ibs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.0618.16 A - B 39 0 F - G 1093 -3227 B - C 998 -2717 G - H 1497 -4276 C - D 1554 -4518 H -1 1479 -4349 D - E 1567 -4436 I - J 1680 -4764 E- F 1110 -3240 J- K 39 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - Q 2353 -734 N - M 3724 -1069 Q- P 29 -9 M- L 3695 -1071 O - N 4105 -1155 L - J 4283 -1411 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C -Q 458 -1201 E -N 619 -1205 C-0 1649 -393 F - N 2386 -684 Q-0 2627 -817 N - G 489 -817 O -P 80 0 G - L 519 -94 O - E 432 -90 L - I 314 -341 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field 488906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. Convrioht n 2016 A-1 Roof Tnra - Rnnrndunhoo of this dnourn—t. in anv formi no inhi e.d without thn written noonit ino of A-1 Roof Tnicc I ARMSCM1560BlL M O °'T T� A09 I­rr� COMN 19' 3398 SEAT PLATE REQ. SEAT PLATE REQ. 38' P"'P"'i 19' j 19' Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.512 N 883 360 Loc R+ / R- / Rh / Rw /U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.970 N 466 240 B 1546 /- /- /870 /199 /314 BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.365 L - - J 1546 /- /- /870 /199 /- EXP: B Kzt: NA Des Ld: 37.00 Plate Type(s): TL 0.692 L HORZ ( ) Wind reactions based on MWFRS Mean Height: 25.00 ft WAVE, HS Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.5 : 1 TCDL: 5.0 psf Max TC CSI: 0.673 J Brg Width = 8.0 Min Req = 1.5 LoadNCBDu on: Load Duration: 1.25 BCDL: 4.2 psf " Max BC CSI: 0.743 Bearings B & J are a rigid surface. Spacing: 24.0 MWFRS Parallel Dist: h to 2h Bearings B & J require a seat plate. C&C Dist a: 3.80 ft Max Web CSI: 0.928 Loc. from endwall: not in 9.00 Maximum Top Chord Forces Per Ply (Ibs) Wgt: 175.0 lbs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 A - B 39 0 F - G 1089 -3229 Lumber B - C 1677 -4758 G - H 1494 -4269 Top chord 2x4 SP M-30 C - D 1471 -4346 H - I 1476 -4346 Bot chord 2x4 SP 2400f -2.0E :B2 2x4 SP M-30: D - E 1488 -4269 I - J 1675 -4758 Webs 2x4 SP #3 E - F 1114-3229 J - K 39 0 Purlins Maximum Bot Chord Forces Per Ply (Ibs) In lieu of structural panels or rigid ceiling use purlins Chords Tens.Comp. Chords Tens. Comp. to laterally brace chords as follows: Chord Spacing(in oc) StEn B - P 4277 -1372 N - M 3732 -1064 BC 120 0.15 37..8585 0.15 P-0 3713 -1026 M - L 3713 -1072 Apply purlins to any chords above or below fillers O - N 3732 -1018 L - J 4277 -1406 at 24" OC unless shown otherwise above. Maximum Web Forces Per Ply (Ibs) Wind Webs Tens.Comp. Webs Tens. Comp. Wind loads based on MWFRS with additional C&C member design. C - P 309 -337 N - G 497 -828 P - E 509 -85 G - L 509 -88 E - N 498 -828 L - 1 311 -337 F - N 2437 -710 *`WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Krislam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -i. C. -Mint 0) 2016 A-1 Roof Ton—– Renmdil Mon of this do-meatin nnv form. is nmhihited withtnit the written nenni-ion of A-1 Rnnf Tn.-., ARMSCM 1560B 1 L A10 COMN i 19' - -{- 19' F - 5X6 (Al) SEAT PLATE REQ. SEAT PLATE RED. 38' F-51191 19' 8'1"6 i 10'101,10- +i11' 3326 Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in Ioc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.467 O 969 360 Loc R+ / R- ! Rh / Rw /U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.883 O 512 240 g 1546 /- /- /870 /199 /314 BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.325 L - - J 1542 /- /- /875 /195 /- EXP: B Kzt: NA Des Ld: 37.00 Plate Type(s): HORZ(TL): 0.614 L Wind reactions based on MWFRS Mean Height: 25.00 ft WAVE, HS Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.5 NCBCLL: 10.00 TCDL: 5.0sf p Max TC CSI: 0.686 J Brg Width = 8.0 Min Req = 1.8 Load Duration: 1.25 BCDL: 4.2 psf " Max BC CSI: 0.749 Bearings B & J are a rigid surface. Spacing: 24.0 MWFRS Parallel Dist: h to 2h Bearings B & J require a seat plate. C&C Dist a: 3.80 ft Max Web CSI: 0.898 Loc. from endwall: not in 9.00 Maximum Top Chord Forces Per Ply (Ibs) Wgt: 193.2 Ibs Chords Tens.Comp. Chords Tens, Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 A - B 39 0 F - G 1082 -3269 Lumber B - C 1684 -4765 G - H 1659 -4613 C - D 1473 -4347 H - I 1651 -4708 Top chord 2x4 SP M-30 :T3 2x4 SP #2: D - E 1491 -4274 I - J 996 -2723 Bot chord 2x4 SP M-30 :61 2x4 SP 2400f -2.0E: E - F 1125 -3238 J - K 39 0 :B4 2x4 SP #2: Webs 2x4 SP #3 :W7 2x4 SP #2: Maximum Bot Chord Forces Per Ply (Ibs) Bracing Chords Tens.Comp. Chords Tens. Comp. (a) Continuous lateral restraint equally spaced on member. B - Q 4285 -1379 0-M 4303 -1306 Plating Notes Q - P 3693 -1020 N - L 33 -12 (1) - plates so marked were sized using 0% Fabrication Tolerance, 10 degrees P-0 3722 -1018 L - J 2361 -758 Rotational Tolerance, and/or zero Positioning Tolerance. Maximum Web Forces Per Ply (Ibs) Purlins Webs Tens.Comp. Webs Tens. Comp. In lieu of structural panels or rigid ceiling use purlins C - Q 315 -345 G - M 421 -65 to laterally brace chords as follows: Q - E 513 95 M - N 74 0 Chord Spacing(in oc) StEnd(ft) 0.15 BC 120 0.15 19.000 E-0 480 -800 M - L 2640 -844 BC 101 19.00 27.22 F-0 2357 -651 M -1 1829 -516 BC 120 27.26 37.85 O - G 703 -1368 L - I 468 -1239 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. Cnnvdnht r7 2016 A.1 Rnnf Tmi .. - Renrndurfinn of fhis in inv Toon. m nrnhihOd without the written nermiccinn of A-1 Rnnf Tmc¢e,. f l ARMSCM1560B1 L I A11 ( HIPS 11 y 11y I 17'8"1 -}- 2714 «i 17'8"1 =5X6 3315 =3X10 1111.5X4 1111.5X4 =5X6 =3X67= -3X4 SEAT PLATE REQ. 1'5"9 �- -�}- 1111"2 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00Risk Category: II Wind reactions based on MWFRS EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: h to 2h Maximum Top Chord Forces Per Ply (Ibs) C&C Dist a: 3.80 ft Chords Tens.Comp. Chords Tens. Comp. Loc. from endwall: not in 9.00 A - B 39 0 G - H 1408 -3982 GCpi: 0.18 B - C 1039 -2715 H - 1 1027 -2394 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2:B2 2x4 SP M-30 Webs 2x4 SP #3:W3 2x4 SP #2: Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes (1) - plates so marked were sized using 0% Fabrication Tolerance, 10 degrees Rotational Tolerance, and/or zero Positioning Tolerance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 17.67 20.33 BC 120 0.15 11.78 BC 104 11.82 20.18 BC 75 20.18 37.85 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. SEAT PLATE REQ. kk➢ 772 ---i- 18'10"10 Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): 0.381 P 999 360 Loc R+ / R- / Rh / Rw /U / RL VERT(CL): 0.719 P 629 240 B 1540 /- /- /877 /199 /295 HORZ(LL): 0.251 M - - K 1540 /- i- /876 /199 /- HORZ(TL): 0.474 M Wind reactions based on MWFRS Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.8 Max TC CSI: 0.618 K Brg Width = 8.0 Min Req = 1.8 Max BC CSI: 0.768 Bearings B & K are a rigid surface. Max Web CSI: 0.978 Bearings B & K require a seat plate. -624 Maximum Top Chord Forces Per Ply (Ibs) Wgt:238.0lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.0618.16 A - B 39 0 G - H 1408 -3982 E - T B - C 1039 -2715 H - 1 1027 -2394 0-H C - D 1629 -4497 I - J 1007 -2442 -1624 D - E 1646 -4438 J - K 1064 -2692 358 -169 E- F 1250 -3364 K- L 39 0 352 F - G 1341 -3514 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - W 2352 -776 R - P 3076 -737 W -V 29 -9 Q -O 7 -3 U - T 4070 -1229 O - N 1976 -624 T - R 3057 -728 N - M 1976 -624 S- Q 1 -2 M- K 2336 -825 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C - W 480 -1203 S - R 65 -36 C - U 1627 -427 P - Q 109 -31 W - U 2628 -866 P - G 1511 -465 U- V 80 0 P-0 2568 -808 U - E 452-111 P - H 1581 -258 E - T 550 -1082 0-H 550 -1624 F - T 358 -169 H - M 352 -105 F - P 1035 -309 M - J 234 -323 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdslam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. Convdnht n 2n1a A-1 Roof Tnis - Renrndeotion of this d- ­t i - O.- fnrrn. i. nrohihited witht the. written nenniscion of A-1 Roof Tnresas. ARMSCM1560B1L IA12 IHIPS (1 1" I v.... NT T 'v 1 N =3} 1 = 168"1 -{ 6'714 - -}- 168"1 it 1111.5X3 =6X10 c � u 3322 =5X6 1111.5X4 1111.5X3 1117X8(R) =3X6 SEAT PLATE REQ. 1'5"9 �- --}-- 11'11"2 Loading Criteria (psf) Wind Criteria Code / Misc Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES TCDL: 10.00 Speed: 160 mph TPI Std: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) Ply (Ibs) EXP: B Kzt: NA Plate Type(s): Des Ld: 37.00 Mean Height: 25.00 ft WAVE NCBCLL: 10.00 TCDL: 5.0 psf 900 -1998 Load Duration: 1.25 BCDL: 4.2 psf E- F 1882 -4559 K- L Spacing: 24.0 " MWFRS Parallel Dist: h to 2h -690 F- P C&C Dist a: 3.80 ft J- M 278 Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2:B2 2x4 SP M-30: Webs 2x4 SP #3:W3, W8, W9 2x4 SP #2: Bracing (a) Continuous lateral restraint equally spaced on member Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 15.67 22.33 BC 120 0.15 11.75 BC 93 11.75 19.26 BC 120 19.26 37.85 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. 7'2"4 0.1 Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.448 G 999 36 VERT(CL): 0.845 G 535 24 HORZ(LL): 0.298 M - HORZ(TL): 0.562 M Creep Factor: 2.0 Max TC CSI: 0.896 Max BC CSI: 0.988 Max Web CSI: 0.897 Wgt: 222.6 lbs VIEW Ver: 19.01.00A.0618.16 SEAT PLATE REQ. 18'101,10 1'5"9i ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw /U / RL B 1540 /- /- /878 /216 /266 K 1539 A /- /877 /216 /- Wind reactions based on MWFRS C-R B Brg Width = 8.0 Min Req = 1.8 K Brg Width = 8.0 Min Req = 1.8 Bearings B & K are a rigid surface. 2649 -915 Bearings B & K require a seat plate. 3180 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A- B 39 0 G- H 1721 -4493 B - C 1084 -2718 H - I 930 -1962 C - D 1724 -4559 I - J 900 -1998 D - E 1745 -4525 J - K 1074 -2657 E- F 1882 -4559 K- L 39 0 F - G 1725 -4516 -690 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - T 2356 -818 O - N 2284 -819 T -S 26 -11 N -M 2284 -819 R - P 3497 -994 M - K 2286 -818 Q -O 12 -5 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C -T 511 -1237 G -P 83 -104 C-R 1674 -470 P- Q 6 0 T - R 2649 -915 P-0 3180 -933 E - R 258 -291 P - H 3974 -1131 R- S 78 0 0-H 679 -2313 R - F 1025 -530 O - J 368 -690 F- P 1474 -443 J- M 278 0 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (Le, Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI -1, (:nnvhnht 0 201E A-1 Rnnf T.,c - Ranmduntion of IhM li-Montin anv formis nrohihitod Wth-1 thn wdttnn n-N.,inn of A-1 R -f T., v ARWCM1560B1 L A13 SPECyPc 1 y (1y v'/ iJ/LULV 15'6" 111011 } 6'11"15 13'8"1 -� F-,-,- _ 1114X6(Ri. 3361 =3X10 1111.5X4 1111.5X3 =5X10 m3X61111.5X3 SEAT PLATE REQ. P"'i 11'11'T 7'2"4 Loading Criteria (psf) Wind Criteria Code / Misc Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES TCDL: 10.00 Speed: 160 mph TPI Std: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 7.00 Risk Category: 11 FT/RT:10(0)/10(10) Chords Tens.Comp. Chords EXP: B Kzt: NA Plate Type(s): Des Ld: 37.00 Mean Height: 25.00 ft WAVE, HS NCBCLL: 10.00 TCDL: 5.0 psf D - E 1825 -4581 J - K Load Duration: 1.25 BCDL: 4.2 psf 1124 -2688 Spacing: 24.0 " MWFRS Parallel Dist: h to 2h 1077 -2636 K- N C&C Dist a: 3.80 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 :T4 2x4 SP M-30: Bot chord 2x4 SP #2 :B2 2x6 SP 2400f--2.OE: Webs 2x4 SP #3:W3, W6, W9 2x4 SP #2: :W11 2x4 SP M-30: Bracing (a) Continuous lateral restraint equally spaced on member Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 17.33 24.33 BC 120 0.15 11.75 BC 91 11.75 19.16 BC 120 19.26 37.85 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. 38' Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.621 Q 729 36 VERT(CL): 1.170 Q 386 24 HORZ(LL): 0.366 N - HORZ(TL): 0.690 N Creep Factor: 2.0 Max TC CSI: 0.737 Max BC CSI: 0.937 Max Web CSI: 0.943 Wgt: 229.6 Ibs VIEW Ver: 19.01.00A.0618.16 SEAT PLATE REQ. ft-1111)fi[t ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw /U i RL B 1540 /- /- /874 /211 /264 L 1539 /- /- /872 /222 /- Wind reactions based on MWFRS 1721 -508 B Brg Width = 8.0 Min Req = 1.8 L Brg Width = 8.0 Min Req = 1.8 Bearings B & L are a rigid surface. 63 0 Bearings B & L require a seat plate. 247 -266 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A- B 39 0 G- H 2028 -5174 B - C 1123 -2718 H - 1 2554 -6623 C - D 1804 -4614 I - J 1008 -2112 D - E 1825 -4581 J - K 982 -2145 E - F 1956 -4593 K - L 1124 -2688 F- G 2369 -5977 L- M 39 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - V 2357 -837 R - P 27 -9 V - U 34 -12 P-0 2320 -876 T - S 3427 -992 O - N 2320 -876 S - Q 6972 -2298 N - L 2322 -874 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C - V 528 -1251 S - H 992 -2725 C - T 1721 -508 H - Q 2122 -690 V- T 2649 -939 Q- R 63 0 E - T 247 -266 Q - P 2476 -814 T - U 78 0 Q-1 5170 -1695 T - F 1160 -593 P-1 468 -1360 F - S 4035 -1535 P - K 311 -564 G- S 1077 -2636 K- N 231 0 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Vedfy design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the content of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI.1 defines the responsibilities and duties of the Truss Fort Pierce, FL 3d946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. (:nnvnnht n 2016 A -i Rnnf Tnrccr_s - Rnnrndnrlinn of this domiment in anv fnrtnRonf Tma¢ec. N ARMSCM1560BlL B01 I COM1 1 ( 3466 2544 t 16g6#� 21 IL- - 7'0"6 T 2'0"6 T2' --i 2 0.6 2'0"6 T "'' 5-4" 7, SEAT PLATE REQ, Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II BC: From 14 pif at 0.00 to EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL• 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft TC: 186 Ib Conc. Load at 9.06,10.27 Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 :T2 2x4 SP M-30: Bot chord 2x4 SP #2 Webs 2x4 SP #3 Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 62 plf at -1.46 to 62 pif at 7.00 TC: From 31 plf at 7.00 to 31 pif at 12.33 TC: From 62 plf at 12.33 to 62 plf at 19.33 BC: From 14 pif at 0.00 to 14 plf at 7.03 BC: From 7 pif at 7.03 to 7 pif at 12.30 BC: From 14 pif at 12.30 to 14 plf at 19.33 TC: 254 Ib Conc. Load at 7.03 TC: 186 Ib Conc. Load at 9.06,10.27 TC: 255 Ib Conc. Load at 12.30 BC: 442 Ib Conc. Load at 7.03 BC: 111 Ib Conc. Load at 9.06,10.27 BC: 448 Ib Conc. Load at 12.30 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 7.00 12.33 BC 59 0.15 19.19 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.102 H 999 36 §fERT(CL): 0.190 H 999 24 HORZ(LL): 0.044 F - - HORZ(TL): 0.082 F Creep Factor: 2.0 Max TC CSI: 0.665 Max BC CSI: 0.992 Max Web CSI: 0.233 Wgt: 81.2 lbs VIEW Ver: 19.01.00A.0618.16 SEAT PLATE REQ. I N N sjI Y 1 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL B 1723 /- /- /- /834 !- E 1630 /- /- /- /772 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 2.0 E Brg Width = 8.0 Min Req = 1.9 Bearings B & E are a rigid surface. Bearings B & E require a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. Chords Tens, Comp. A - B 39 -26 C - D 1303 -2743 B - C 1496 -3090 D - E 1507 -3099 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - H 2681 -1284 G - F 2705 -1287 H - G 2705 -1287 F - E 2693 -1296 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - H 594 -74 F - D 612 -80 C -F 46 -19 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. Cnnvrinht CO 20% AA Rnnf Tmssas - Ranrndnntina of this dnnimnnt in anv form. is nrnhihited mthniJ tha wdHan rw mainn of AA Rnnf Tnresas 19'4° 114 448# 111# Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.102 H 999 36 §fERT(CL): 0.190 H 999 24 HORZ(LL): 0.044 F - - HORZ(TL): 0.082 F Creep Factor: 2.0 Max TC CSI: 0.665 Max BC CSI: 0.992 Max Web CSI: 0.233 Wgt: 81.2 lbs VIEW Ver: 19.01.00A.0618.16 SEAT PLATE REQ. I N N sjI Y 1 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL B 1723 /- /- /- /834 !- E 1630 /- /- /- /772 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 2.0 E Brg Width = 8.0 Min Req = 1.9 Bearings B & E are a rigid surface. Bearings B & E require a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. Chords Tens, Comp. A - B 39 -26 C - D 1303 -2743 B - C 1496 -3090 D - E 1507 -3099 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - H 2681 -1284 G - F 2705 -1287 H - G 2705 -1287 F - E 2693 -1296 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - H 594 -74 F - D 612 -80 C -F 46 -19 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. Cnnvrinht CO 20% AA Rnnf Tmssas - Ranrndnntina of this dnnimnnt in anv form. is nrnhihited mthniJ tha wdHan rw mainn of AA Rnnf Tnresas 1 russ 1 ype Uty Ply 07/13/2020 ARMSCM1560BlL (B02 I HIPS 11 11 I 3470 9' 1'4" %5X6(CR) T2 XD(R) 8'7"12 -{ Loading Criteria (psf) TOLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " SEAT PLATE REQ. Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 :T2 2x4 SP #2: Bot chord 2x4 SP #2 Webs 2x4 SP #3 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 9.00 10.33 BC 83 0.15 18.89 Apply purlins to any chords above or below fillers at 24" CIC unless shown otherwise above. =bXb IIII.bx;5 18'11"12 Code / Misc Criteria Defl/CSI Criteria Code: FBC 2017 RES PP Deflection in loc L/deft L/# TPI Std: 2014 VERT(LL): 0.028 G 999 36 Rep Factors Used: Yes VERT(CL): 0.072 G 999 24 FT/RT:10(0)/10(10) HORZ(LL): 0.016 G - - Piate Type(s): HORZ(TL): 0.040 G WAVE Creep Factor: 2.0 Max TC CSI: 0.723 Max BC CSI: 0.968 Max Web CSI: 0.090 Wgt: 75.6 lbs VIEW Ver: 19.01.00A.0618.16 Wind Wind loads based on MWFRS with additional C&C member design. =3X4(B1) SEAT PLATE REQ. ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw /U / RL B 818 /- /- /470 /358 /142 E 719 /- /- /379 /303 A Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 E Brg Width = 3.8 Min Req = 1.5 Bearings B & E are a rigid surface. Bearings B & E require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A- B 39 0 C- D 494 -824 B - C 436 -1030 D - E 455 -1033 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - G 821 -270 F - E 821 -269 G - F 824 -269 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - G 237 -90 F - D 237 -82 -WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TOD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Krislam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field #88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. (',. v inhf n 201E A -i Rnnf Tnissas– RenrnAllMlnn of ihis Anraimnnt. in anv fnnn. is nrnhihil.d wilhnut tha wnftP nvnni,cm of A-1 Rnnf T.,-.,. ARMSCM1560Bl L N in =3X4(A1) BB ys A /its B03 ISPEC 9,8„ 9'3"12 ft! D= -4X4 12 6 F,—,- t 1111.5X3 C E 1111.5X3 1_0 m in F=3X4(B1)Pi gT5 1 I H G =3X4 =3X4 =3X4 SEAT PLATE REQ. Loading Criteria (pst) Wind Criteria Code / Misc Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES TCDL: 10.00 Speed: 160 mph TPI Std: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) EXP: B Kzt: NA Plate Type(s): Des Ld: 37.00 Mean Height: 25.00 ft WAVE NCBCLL: 10.00 TCDL: 5.0 psf Max BC CSI: 0.975 Load Duration: 1.25 BCDL: 4.2 psf Max Web CSI: 0.231 Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Wgt:85.4lbs Loc. from endwall: not in 9.00 VIEW Ver: 19.01.00A.0618.16 A - B 39 0 D - E 612 -1230 GCpi: 0.18 B - C 515 -1301 E - F 499 -1251 Wind Duration: 1.60 C - D 630 -1287 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 110 0.15 18.89 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design SEAT PLATE REQ. 18'11"12 2530 Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/deft L/# Gravity Non -Gravity VERT(LL): 0.047 G 999 360 Loc R+ J R- J Rh / Rw /U / RL VERT(CL): 0.088 G 999 240 B 818 /_ /_ /468 /357 /151 HORZ(LL): 0.019 G - F 719 /- /- /377 /302 /- HORZ(TL): 0.036 G Wind reactions based on MWFRS Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.362 F Brg Width = 3.8 Min Req = 1.5 Max BC CSI: 0.975 Bearings B & F are a rigid surface. Max Web CSI: 0.231 Bearings B & F require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:85.4lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.0618.16 A - B 39 0 D - E 612 -1230 B - C 515 -1301 E - F 499 -1251 C - D 630 -1287 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-1 1114 -407 H - G 693 -209 1- H 693 -209 G - F 1062 -392 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C-1 245 -253 D - G 483 -217 I - D 547 -238 G - E 240 -235 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' forth. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. r:nnvnnhf t7 2n7fi A-1 Rnnt Tnicsp_v – RcnmAnrlinn of thio tlnra�mfinf in fine forth. in nmhihitmn W1hnmt thn wnftnn —1—inn of AA Rmf TmIC .1 bb ARMSCM1560B1L ( C01 I HIPMyPc I 1ty I 1y I U//16/ZULU 2572 4094 !{ 186# 16t �'--7,0"6 i 2.0.6 2- 11" F- 7' i 4'11'12 -� SEAT PLATE REQ. SEAT PLATE REQ. 11'11"12 1'5"9-'1 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form, verify, design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms areas defined in TPI -1. Cnnvdnht Z 2016 A-1 Roof Tosc - Ranrndnrtion of thic dncomnni. in env fnnn. is nrohihited Athnot tha written ne.miccinn of A -i Ronf Tnf aea 4 11# + 582# 111# Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/deft L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.029 F 999 360 Loc R+ / R- / Rh / Rw /U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Varies by Ld C %0ERT(CL): 0.053 F 999 240 B 1027 /- !- !- /509 /- BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.009 E - - E 1370 /- /- /- /675 /- EXP: B Kztfight NA 37.00 Plate Type(s): HORZ TL 0.017 E Wind reactions based on MWFRS Mean Height: 25.00 ft WAVE Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.5 NCBDes CLLd: : 1 TCDL: 5.0 psf Load Max TC CSI: 0.769 E Br Width = 3.8 Min Re 1.6 g q = Du Load Duration: 1.25 BCDL: 4.2 psf on: Bearings B & E are a rigid surface. Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 Max BC CSI: 0.977 Bearings B & E require a seat plate. C&C Dist a: 3.00 ft Max Web CSI: 0.385 Loc. from l: not in 4.50 Maximum Top Chord Forces Per Ply (Ibs) GCpi: i: 0 0.. 118 Wgt: 65.8 lbs Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 A - B 39 -26 C - D 12 -18 Lumber B - C 774 -1573 TOP chord 2x4 SP #2:T2 2x4 SP M-30: Bot chord 2x6 SP #2 Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 Chords Tens.Comp. Chords Tens. Comp. Bracing B - F 1317 -631 F - E 1351 -637 (a) Continuous lateral restraint equally spaced on member. Maximum Web Forces Per Ply (lbs) Special Loads Webs Tens.Comp. Webs Tens. Comp. ---(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) C - F 806 -145 D - E 252 -318 TC: From 62 pif at -1.46 to 62 plf at 7.00 C - E 762 -1625 TC: From 31 plf at 7.00 to 31 plf at 11.98 BC: From 14 plf at 0.00 to 14 pif at 7.03 BC: From 7 plf at 7.03 to 7 pif at 11.98 TC: 409 Ib Conc. Load at 7.03 TC: 186 Ib Conc. Load at 9.06,11.06 BC: 582 Ib Conc. Load at 7.03 BC: 111 Ib Conc. Load at 9.06,11.06 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 7.00 11.98 BC 101 0.15 11.98 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Right end vertical not exposed to wind pressure. -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form, verify, design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms areas defined in TPI -1. Cnnvdnht Z 2016 A-1 Roof Tosc - Ranrndnrtion of thic dncomnni. in env fnnn. is nrohihited Athnot tha written ne.miccinn of A -i Ronf Tnf aea ARMSCM1560BlL I CO2 HIM -- IPM r 11 1 4 9' - -1 2'11"12 —� SEAT PLATE REO. SEAT PLATE REQ. i- I V11"12 1 �-- VV9 -� 3407 . Loading Criteria (psq Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.036 F 999 360 Loc R+ / R- / Rh / Rw /U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.067 F 999 240 B 556 A /- /366 /203 /265 BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.023 F - - E 446 /- /- /256 /236 /- EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.042 F - - Wind reactions based on MWFRS Des Ld: 37.00 Mean Height: 25.00 ft WAVE Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.5 NCBCLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0.594 E Brg Width = 3.8 Min Req = 1.5 Load Duration: 1.25 BCDL: 4.2sf p " Max BC CSI: 0.982 Bearings B & E are a rigid surface. Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2 Bearings B & E require a seat plate. C&C Dist a: 3.00 ft Max Web CSI: 0.252 Loc. from endwall: not in 9.00 Maximum Top Chord Forces Per Ply (Ibs) Wgt: 58.8 lbs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 A - B 39 0 C - D 0 0 Lumber B - C 73 -413 Top chord 2x4 SP 2400f-2.OE :T2 2x4 SP #2: Bot chord 2x4 SP #2 Maximum Bot Chord Forces Per PI Ibs y (Ibs) Webs 2x4 SP #3 Chords Tens.Comp. Chords Tens. Comp. Purlins B - F 254 -167 F - E 260 -167 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Maximum Web Forces Per Ply (Ibs) Chord Spacing(in oc) Start(ft) End(ft) Webs Tens.Comp. Webs Tens. Comp. TC 24 9.00 11.98 BC 111 0.15 11.98 C - F 309 0 D - E 89 92 Apply purlins to any chords above or below fillers C - E 304 -474 at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design Right end vertical not exposed to wind pressure. -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineer n responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St, Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI.1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPIA. r: vrinhtn 2016 A-1 Rnof TmcsPc — Rnnrodnrtinn of this dmtimont in anvfnnn m nrohihitad without thn v,df.n --i. -inn of A-1 Rnnf TnICCPz. I ARMSCM1560BlL 4'3 CO3 I �� MONOyP � i.y 2 Iriy vn iof<u�u 1 no SEAT PLATE REQ. SEAT PLATE REQ, 1 11'11"12 E— 1'5„9 -_ 3401 Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria A Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/deli L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.011 F 999 360 Loc R+ / R- / Rh / Rw /U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.020 F 999 240 B 556 /- /- /363 /168 /343 BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.005 E - - E 446 /- /- /299 /267 /- EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft Plate Type(s): WAVE HORZ TL ( ): 0.009E Wind reactions based on MWFRS NCBCLL: 10.00 TCDL: 5.0 psf Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.5 Load Duration: 1.25 BCDL: 4.2 psf Max TC CSI: 0.568 E Brg Width = 3.8 Min Req = 1.5 Spacing: 24.0 ” MWFRS Parallel Dist: 0 to h/2 Max BC CSI: 0.974 Bearings B & E are a rigid surface. C&C Dist a: 3.00 Max Web CSI: 0.443 Bearings B & E require a seat plate. Loc. from i:: not in 9.00 Maximum Top Chord Forces Per Ply (Ibs) i: 0 0.1.18 GCpi: Wgt: 61.6 lbs Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 A - B 39 0 C - D 60 -102 Lumber B - C 90 -625 Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 Chords Tens.Comp. Chords Tens. Comp. Purlins B - F 495 -299 F - E 493 -300 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Maximum Web Forces Per Ply (Ibs) Chord Spacing(in oc) Start(ft) End(ft) Webs Tens.Comp. Webs Tens. Comp. BC 119 0.15 11.98 Apply purlins to any chords above or below fillers F - C 238 0 D - E 166 -135 at 24" OC unless shown otherwise above. C - E 346 -567 Wind Wind loads based on MWFRS with additional C&C member design Right end vertical not exposed to wind pressure. **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. Cnnvrinhi 0 2016 A-1 Rnnf TniscP_c– Rnnrndnntinn of thin d -t --t in my fmmn in nrnhihitedwithtnit the wnftnn nrrrnicninn of A-1 Rnnf Tnieaev ARMSCM1560BlL I E01 I GABL M T M i i- - 4'6" F///4X8(RI) 4'6" —� 2514 1'0"8 1'0"8 6'11" f— 1,5„9 „1 9' Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: > 2h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 9.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE Loading Truss designed to support 2-0-0 top chord outlookers and cladding load not to exceed 8.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Wind Wind loads based on MWFRS with additional C&C member design. Left end vertical exposed to wind pressure. Deflection meets L/360. Right end vertical not exposed to wind pressure. Left and right cantilevers are exposed to wind Left bottom chord exposed to wind. Additional Notes See STD DETAILS for gable wind bracing requirements. Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): -0.062 B 255 36C §It_RT(CL): 0.058 J 275 240 HORZ(LL): -0.034 B - HORZ(TL): 0.036 B Creep Factor: 2.0 Max TC CSI: 0.631 Max BC CSI: 0.551 Max Web CSI: 0.353 Wgt: 91.0 Ibs VIEW Ver: 19.01.00A.0618.16 1'gg "� ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw /U / RL R 938 /- /- /556 /600 /274 N 938 /- /- /463 /610 /- Wind reactions based on MWFRS R Brg Width = 3.5 Min Req = 1.5 N Brg Width = 3.5 Min Req = 1.5 Bearings R & N are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A- B 82 0 F- G 346 -73 B - C 121 -53 G - H 296 -83 C -D 137 -33 H-1 115 0 D -E 265 -126 I -J 102 -18 E- F 368 -109 J- K 82 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp T -S 78 -67 P -O 165 -119 S -R 78 -66 O -N 165 -119 R -Q 165 -119 N -M 56 -30 Q -P 165 -119 M -L 58 -31 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp B - T 267 -158 F - W 127 -245 D - R 527 -406 X - N 160 -260 R - U 113 -244 N - H 530 -406 V - F 104 -252 J - L 276 -156 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp C - S 57 -63 W - G 167 -160 U -Q 175 -165 O -X 147 -165 E -V 188 -160 M-1 59 -71 P - F 112 -123 '*WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms areas defined in TPI -i. C:nnvdnht n 2016 A-1 Roof Tniese_s – Renroduotion of thic do -re t in anv f0 i., nrnhihited without the wntien nermiasion of A-1 Ronf Tnt¢ses. JVY IIUJJ ARMSCM1560BlL E02 hubs type COMN 4'6° wty I 1y I unl3/ZuLu �----- 4'6" ---{ D=4X4 i �— 1'5"g 1'0"S 6'11" 1 V g1,5„g -' 2587 Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): -0.027 F 592 360 Loc R+ / R- / Rh / Rw /U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.038 F 419 240 J 454 /- /- /362 /199 /172 BCDL: 7.00 Risk Category: 11 FT/RT:10(0)/10(10) HORZ(LL): 0.014 F - - 1 454 /- /- /262 /96 /- EXP: B Kzt: NA Des 37.00 Plate Type(s): HORZ(TL): 0.019 F Wind reactions based on MWFRS Mean Height: 25.00 ft WAVE Creep Factor: 2.0 J Br Width = 3.5 Min Re 1.5 9 q = CLLd: NCBCLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0.434 1 Brg Width = 3.5 Min Req = 1.5 Load Duration: 1.25 BCDL: 4.2 psf ” Max BC CSI: 0.464 Bearings J & I are a rigid surface. Spacing: 24.0 MWFRS Parallel Dist: > 2h C&C Dist a: 3.00 ft Max Web CSI: 0.195 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 9.00 Chords Tens.Comp. Chords Tens. Comp. Wgt: 65.8 Ibs GCpi: 0.18 A - B 39 0 D - E 161 -44 Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 B - C 60 -54 E - F 60 -23 Lumber C - D 193 -89 F - G 39 0 Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 Chords Tens.Comp. Chords Tens. Comp. Purlins K - J 75 -48 1- H 38 -17 In lieu of structural panels or rigid ceiling use purlins J-1 78 -61 to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) Maximum Web Forces Per Ply (Ibs) BC 75 0.00 9.00 Webs Tens.Comp. Webs Tens. Comp. Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. B - K 167 -113 D-1 75 -125 C - J 314 -234 I - E 342 -234 Wind J - D 82 -125 F - H 87 -66 Wind loads based on MWFRS with additional C&C member design. Left end vertical exposed to wind pressure. Deflection meets L/360. Right end vertical not exposed to wind pressure. Left and right cantilevers are exposed to wind Left bottom chord exposed to wind. -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -I. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. Convdnht cn 2016 AA Roof Tni—%– Ranrndnotion of this don, imant. in nnv form. Is nrohihited without tho wdttan nnnnission of A-1 Roof Tnncsws. ARMSCM1560BlL I E03 I COMN~ 11" 1" j- 4'0"8 i 4'0"8 ---{ a I C=4X4 F15 6'11" i y 8'0"15 X3 1111.5X3 K3 2511 I Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defi/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/deft L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): -0.011 F 933 360 Loc R+ / R- / Rh / Rw /U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): -0.015 F 999 240 H 304 /- /0 /225 /130 /133 BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.007 A - - G 317 /- /- /222 /86 !- EXP: B Kzt: NA Des Ld: 37.00 Plate Type(s): HORZ(TL): 0.011 A Wind reactions based on MWFRS Mean Height: 25.00 ft WAVE Creep Factor: 2.0 H Brg Width = 3.5 Min Req = 1.5 : 10.00 TCDL: 5.0 psf NCBLoad Max TC CSI: 0.260 G Brg Width = 3.5 Min Req = 1.5 Du Load Duration: 1.25 BCDL: 4.2 psf " Max BC CSI: 0.379 Bearings H & G are a rigid surface. Spacing: 24.0 MWFRS Parallel Dist: h to 2h C&C Dist a: 3.00 ft Max Web CSI: 0.199 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 9.00 Chords Tens.Comp. Chords Tens. Comp. Wgt: 60.2 Ibs GCpi:0.18 A - B 49 -91 C -D 109 -47 Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 B - C 162 -83 D - E 75 -67 Lumber Top chord 2x4 SP #2 Maximum Bot Chord Forces Per Ply (lbs) Bot chord 2x4 SP #2 Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP #3 I - H 166 -157 G -F 9 -17 Purlins H - G 80 -43 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Maximum Web Forces Per Ply (Ibs) Chord Spacing(in oc) Start(ft) End(ft) Webs Tens.Comp. Webs Tens. Comp. BC 97 0.00 8.08 Apply purlins to any chords above or below fillers A - I 129 -136 C - G 99 -132 at 24" OC unless shown otherwise above. B - H 246 -109 G - D 275 -132 H -C 128 -126 E -F 127 -133 Wind Wind loads based on MWFRS with additional C&C member design. Left end vertical exposed to wind pressure. Deflection meets L/360. Right end vertical not exposed to wind pressure. Left and right cantilevers are exposed to wind Left bottom chord exposed to wind. "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field If 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. C.nnvdnht 0 2016 A-1 Roof To..– Rnnmd-Ainn of IN., dornm-1 in anv form. is nmhihitnd Wlhmit thn vmttnn n—b—inn of A-1 Roof Tnieces ARMSCM1560B1L I E04 ( GABLYPU 1fy ( 1y �— 3'9"4 3'9"4 --{ 12 6 F�;;- C04X10(R11 J =3X3 I H G =3X3 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. End verticals not exposed to wind pressure. Additional Notes See STD DETAILS for gable wind bracing requirements. U //"13/LULU 3456 ♦ Maximum Reactions (Ibs), or *=PLF Gravity Non -Gravity Loc R+ ! R- / Rh / Rw /U / RL J* 72 1- l- 139 /12 /7 O 78 /- /- /73 /35 /- Wind reactions based on MWFRS J Erg Width = 83.3 Min Req = - O Brg Width = 7.2 Min Req = 1.5 Bearings J & O are a rigid surface. Bearing O requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A -B 33 -18 C -D 126 -30 B -C 126 -30 D -E 33 -18 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. J-1 29 -22 H - G 29 -22 1- H 29 -22 G - F 29 -22 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. SEAT PLATE REQ. Tens. Comp. 7VT Loading Criteria (psf) Wind Criteria Code / Misc Criteria J - K Defl/CSI Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES 53 -70 PP Deflection in loc L/deft L/# TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.001 B 999 361 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.002 B 999 241 BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.001 D - Des Ld:CL 37.00 EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.002 D Mean Height: 25.00 ft WAVE NCBL: 10.00 TCDL: 5.0 psf Creep Factor: 2.0 Load Duration: 1.25 BCDL: 4.2 psf Max TC CSI: 0.068 Spacing: 24.0 " MWFRS Parallel Dist: h to 2h Max BC CSI: 0.027 C&C Dist a: 3.00 ft Max Web CSI: 0.059 Loc. from endwall: not in 9.00 Wgt: 100.8 Ibs GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 90 0.00 7.54 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. End verticals not exposed to wind pressure. Additional Notes See STD DETAILS for gable wind bracing requirements. U //"13/LULU 3456 ♦ Maximum Reactions (Ibs), or *=PLF Gravity Non -Gravity Loc R+ ! R- / Rh / Rw /U / RL J* 72 1- l- 139 /12 /7 O 78 /- /- /73 /35 /- Wind reactions based on MWFRS J Erg Width = 83.3 Min Req = - O Brg Width = 7.2 Min Req = 1.5 Bearings J & O are a rigid surface. Bearing O requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A -B 33 -18 C -D 126 -30 B -C 126 -30 D -E 33 -18 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. J-1 29 -22 H - G 29 -22 1- H 29 -22 G - F 29 -22 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A - J 54 -40 C - M 50 -66 J - K 54 -69 N - F 50 -66 L - C 53 -70 E - F 54 -40 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp K-1 201 -145 M - D 195 -140 B -L 195 -140 G -N 201 -145 H -C 0 -45 *"WARNING`* Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing JDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1" The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. (:nnvdnht n 2016 A-1 Ronf TnIG . – R.nrnd-Am of Ihie d --cit. in anv fnrrn. is nmhihifed Wth-1 the wdtten nermi-1- of AA Rnnf Tniccn.¢ ARMSCM1560B1L ( GE01 EJAC 7"2 �--�— 2'0"14 --{ 12 6 1111,5X38 m 'v A Li1-era E 111,5X4 D SEAT P11%P T MIATEBBROPLATE REQ. r— 1 -- j 1'8" —� 2 4 8 2,8„ Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): NA BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): NA BCDL: 7.00 Risk Category: 11 FT/RT:10(0)/10(10) HORZ(LL): 0.000 C EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.000 C Des Ld: 37.00 Mean Height: 25.00 ft WAVE NCBCLL: 10.00 TCDL: 5.0 psf Creep Factor: 2.0 Load Duration: 1.25 BCDL: 4.2 psf Max TC CSI: 0.105 Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h Max BC CSI: 0.029 C&C Dist a: 3.00 ft Max Web CSI: 0.051 Loc. from endwall: not in 9.00 Wgt: 9.8 lbs GCpi: 0.18 VIEW Ver: 19.01.00A.0618.16 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Plating Notes All plates are 2X4(D8R) except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 32 0.00 2.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design ♦ Maximum Reactions (Ibs) Gravity Loc R+ / R- ! Rh 2533 41 Non -Gravity /Rw /U /RL A 106 /- /- /37 /10 /36 D 47 /- /- /18 /- E 84 !- /- /54 /32 /- Wind reactions based on MWFRS A Brg Width = 8.0 Min Req = 1.5 D Brg Width = 8.0 Min Req = 1.5 E Brg Width = 16.0 Min Req = 1.5 Bearings A, D, & D are a rigid surface. Bearings A, D, & D require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. A - B 25 -58 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A -C 9 -13 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. B -C 110 -74 —WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms areas defined in TPI -1. r:nnvdnht n 21116 A-1 Roof Tme-e., — Renmdnntinn of fhis dominentin nnv formis nmhihited without the written nem i -inn of A-1 Rnnf Tmcven. ARMSCM1560BIL HIPHIPS type Joij ury rty 2 1 1 -25# 255# 129# 1,5,8 .-, - 2,9"15 ,--t^- 2,9"15 -' 2,8"11 D U //13/2uzu SEAT PLATE REQ. I --l-11-13 -1- 9110"1 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II TC: 255 Ib Cone. Load at 7.12 EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 WAVE C&C Dist a: 3.00 ft Wind reactions based on MWFRS Loc. from endwall: not in 4.50 Max TC CSI: 0.520 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP M-30 Webs 2x4 SP #3 Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 0 pif at -1.98 to 61 plf at -0.10 TC: From 2 plf at -0.10 to 2 plf at 9.84 BC: From 2 pif at 0.00 to 2 pif at 9.84 TC: -25 Ib Cone. Load at 1.46 Gravity Non -Gravity TC: 129 Ib Cone. Load at 4.29 VERT(LL): 0.021 F 999 360 TC: 255 Ib Cone. Load at 7.12 B 321 /- /- /- /258 /- BC: 10 Ib Cone. Load at 1.46 §tRT(CL): 0.053 F 999 240 BC: 86 ib Cone. Load at 4.29 HORZ(LL): 0.009 F - - BC: 155 Ib Cone. Load at 7.12 Plate Type(s): Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 116 0.15 9.84 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. 2590 i 86# 4 10# 155# Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in Joe L/defl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.021 F 999 360 Loc R+ / R- / Rh / Rw / U / RL B 321 /- /- /- /258 /- Rep Factors Used: Varies by Ld C §tRT(CL): 0.053 F 999 240 FT/RT:10(0)/10(10) HORZ(LL): 0.009 F - - E 331 /- !- !- /133 /- Plate Type(s): HORZ(TL): 0.022 F D 68 /- /- /- /55 /- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.520 B Brg Width = 10.6 Min Req = 1.5 Max BC CSI: 0.619 E Brg Width = 1.5 Min Req = - Max Web CSI: 0.264 D Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Wgt: 39.2 lbs Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver: 19.01.00A.0618.16 Chords Tens.Comp. Chords Tens. Comp. A -B 19 -13 C -D 50 -66 B - C 400 -494 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B- F 487 -352 F- E 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 382 -529 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. Convrnht n 2016 A-1 Roof Tni-ne - Renmdunlinn of Ihit donnment in aev forn. is nmhihited without the wdtlen nennirsinn of A-1 Ronf Tnjcaes ARMSCM1560Bl L HJ7A V � 'y I r-ry 1 1 -254 101# 146# I-- 1'5'8 -�- 2'9"15 1-'i- 1'7" 1 2' 127# # 10 8 + 110"2 -{ D SEAT PLATE REQ. I--1'11"13 }- 9110"1 -t Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II TC: EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 127 Ib Conc. Load at 7.12 C&C Dist a: 3.00 ft TC: Loc. from endwall: not in 4.50 GCpi: 0.18 10 Ib Conc. Load at 1.46 Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 Bot chord 2x6 SP #2 Webs 2x4 SP #3 Special Loads ---(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 61 pif at -1.98 to 61 pif at 1.46 TC: From 31 pif at 1.46 to 31 pif at 9.84 BC: From 7 plf at 0.00 to 7 pif at 9.84 TC: -25 Ib Conc. Load at 1.46 TC: 129 Ib Conc. Load at 4.29 TC: 101 Ib Conc. Load at 5.87 TC: 127 Ib Conc. Load at 7.12 TC: 146 Ib Conc. Load at 7.99 BC: 10 Ib Conc. Load at 1.46 BC: 86 Ib Conc. Load at 4.29 BC: 62 Ib Conc. Load at 5.87 BC: 77 Ib Conc. Load at 7.12 BC: 88 Ib Conc. Load at 7.99 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 99 0.15 9.84 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. + 86# + 77# + 10# 62# 88# Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/deft L/# VERT(LL): 0.032 C 999 36, €tRT(CL): 0.057 C 999 24, HORZ(LL): 0.008 C - HORZ(TL): 0.014 C - Creep Factor: 2.0 Max TC CSI: 0.554 Max BC CSI: 0.993 Max Web CSI: 0.680 Wgt: 49.0 Ibs VIEW Ver: 19.01.00A.0618.16 2569 10 a ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw /U / RL G 640 /- /- /- /465 /- E 471 /- /0 /- /173 /- D 223 /- /- /- /181 /- Wind reactions based on MWFRS G Brg Width = 10.6 Min Req = 1.5 E Brg Width = 1.5 Min Req = - D Brg Width = 1.5 Min Req = - Bearing G is a rigid surface. Bearing G requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A -B 39-27 C -D 121 -150 B - C 822 -1065 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B- F 1044 -756 F- E 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 784 -1082 *'WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field If 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. r-n.ht a) 201E A-1 Rmf T-.. - Ramndn Jinn M Ihi., m anv form. ix nrnhihifnd without the. wnftnn nr:rrnistinn M A-1 Rnnf Tri-., ARMSCM1560B1 L HJ7B HIP_ - 3463 T d'3 -25# 260# 140# E-- 1,5,8 -�- 2'9"15 --- - 2'9"15 -- t 2'8"11 _--� 0 SEAT PLATE REQ. 1'11"13 1 9110"1 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II Rep Factors Used: Varies by Ld C EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 Wind reactions based on MWFRS C&C Dist a: 3.00 ft Max TC CSI: 0.533 Loc. from endwall: not in 9.00 GCpi: 0.18 E Brg Width = 1.5 Min Req = - Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP M-30 Webs 2x4 SP #3 Special Loads ----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 0 pif at -1.98 to 61 pif at -0.10 TC: From 2 plf at -0.10 to 2 pif at 9.84 BC: From 2 plf at 0.00 to 2 plf at 9.84 TC: -25 Ib Cone. Load at 1.46 Loc R+ / R- / Rh / Rw / U / RL TC: 140 Ib Cone. Load at 4.29 Rep Factors Used: Varies by Ld C TC: 260 Ib Cone. Load at 7.12 FT/RT:10(0)/10(10) BC: 10 Ib Cone. Load at 1.46 E 337 /- A A /139 /- BC: 86 Ib Cone. Load at 4.29 HORZ(TL): 0.022 F BC: 153 Ib Cone. Load at 7.12 WAVE Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 116 0.15 9.84 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. 4 86# 4 10# 153# Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in Joe L/defl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.021 F 999 360 Loc R+ / R- / Rh / Rw / U / RL B 321 /- /- /- /264 A Rep Factors Used: Varies by Ld C §PERT(CL): 0.053 F 999 240 FT/RT:10(0)/10(10) HORZ(LL): 0.009 F - - E 337 /- A A /139 /- Plate Type(s): HORZ(TL): 0.022 F D 69 A A /- /57 A WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.533 B Brg Width = 10.6 Min Req = 1.5 Max BC CSI: 0.618 E Brg Width = 1.5 Min Req = - Max Web CSI: 0.274 D Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Wgt: 39.2 lbs Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 19.01.00A.0618.16 Chords Tens.Comp. Chords Tens. Comp. A -B 19 -13 C -D 52 -67 B - C 419 -513 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B- F 505 -369 F- E 0 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - F 401 -548 *'WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e, Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerm responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -t. (:onvrinht n 2n1a A.1 Roof Tni.%. � - Ronrod-Dion of this d-u-nt in anv Co-. N nmhihitad without the written nannievnn of AA Roof To- JVU ARMSCM1560BlL HJ7I IUJJP IIUJJ 1yNc terry r-ly HIP_ (1 1 VIII /GUG -25# 255# 129# 2'9"15 -i-- 2'9"15 ----- 2'8"11 -� 19 SEAT PLATE REQ. E-- 111"13 - -1- 9110"1 _1 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II TC: 255 Ib Cone. Load at 7.12 EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 WAVE C&C Dist a: 3.00 ft Wind reactions based on MWFRS Loc. from endwall: not in 4.50 Max TC CSI: 0.520 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP M-30 Webs 2x4 SP #3 Special Loads ----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 0 pif at -1.98 to 61 plf at -0.10 TC: From 2 plf at -0.10 to 2 plf at 9.84 BC: From 2 plf at 0.00 to 2 plf at 9.84 TC: -25 Ib Cone. Load at 1.46 Gravity Non -Gravity TC: 129 Ib Cone. Load at 4.29 VERT(LL): -0.035 F 999 360 TC: 255 Ib Cone. Load at 7.12 B 321 A /- A /320 /- BC: 10 Ib Cone. Load at 1.46 ktRT(CL): 0.053 F 999 240 BC: 86 lb Cone. Load at 4.29 HORZ(LL): -0.014 F - - BC: 155 Ib Cone. Load at 7.12 Plate Type(s): Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 116 0.15 9.84 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Left bottom chord exposed to wind. 2499 d d d 86# 10# 155# Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (lbs) Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): -0.035 F 999 360 Loc R+ / R- / Rh / Rw / U / RL B 321 A /- A /320 /- Rep Factors Used: Varies by Ld C ktRT(CL): 0.053 F 999 240 FT/RT:10(0)/10(10) HORZ(LL): -0.014 F - - E 331 A /- A /257 /- Plate Type(s): HORZ(TL): 0.022 F D 68 /- /- A /45 A WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.520 B Brg Width = 10.6 Min Req = 1.5 Max BC CSI: 0.967 E Brg Width = 1.5 Min Req = - Max Web CSI: 0.264 D Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Wgt: 39.2 lbs Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver: 19.01.00A.0618.16 Chords Tens.Comp. Chords Tens. Comp. A -B 19 -13 C -D 52 -66 B - C 452 -494 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B -F 487 -412 F -E 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 447 -529 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Krislam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. (:nnvdnht (t7 2016 A-1 Rnof Tn,.,.,- - Renrnd.inlinn of this doc.iiment in anv fnnn. it nrnhihited withnnl the written ...nni-i.n of A-1 Rnnf T.l ... k I ARMSCM1560Bl L I J1„ 4"3 1 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 10 0.15 1.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. nry uaa iyNc t1rly U//7J/LULU JACK 18 11 2593 12 C 6 � � 2X4(A1) B Z T o r _ A D I SEAT PLATE REQ. 1'5"9 — m1a— 1' --- Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): -0.000 D HORZ(TL): 0.000 D Creep Factor: 2.0 Max TC CSI: 0.346 Max BC CSI: 0.046 Max Web CSI: 0.000 Wgt: 5.6 Ibs VIEW Ver: 19.01.00A.0618.16 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 218 /- /- /196 /115 /57 D 5 /-14 A /19 /17 /- C - /-40 /- /44 /50 A Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A -B 39 0 B -C 68 -33 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B -D 0 0 "WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St, Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. C:onvnohl 0 201E A-1 Roof Tom-- Re—ndndion of this d—ment in anv fom. is nmhihitod without tho wnMPn nermissinn of A-1 Roof Tocs .fw f f uss r i use rypu tdty My off 1,XZ000 ARMSCM1560BlL J1P JACK 2 1 2487 12 C 2X4(A1) B co T o 10 A D r SEAT PLATE REQ. 1'5"9 —a 1' —� Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): NA Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): NA B 218 /_ /. /206 /116 /57 BCDL: 7.00Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.000 D D 5 /-14 /- /16 /9 / EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.000 D C - /-40 /- /41 /54 /- Des Ld: 37.00 Mean Height: 25.00 ft WAVE NCBCLL: 10.00 TCDL: 5.0 psf Creep Factor: 2.0 Wind reactions based on MWFRS Load Duration: 1.25 BCDL: 4.2sf Max TC CSI: 0.346 B Brg Width = 8.0 Min Req = 1.5 p D Brg Width = 1.5 Min Req = - Max BC CSI: 0.043 Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C Brg Width = 1.5 Min Req = - C&C Dist a: 3.00 ft Max Web CSI: 0.000 Bearing B is a rigid surface. Loc. from endwall: Any Wgt: 5.6 lbs Bearing B requires a seat plate. GCpi: 0.18 Maximum Top Chord Forces Per Ply (Ibs) Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 Chords Tens.Comp. Chords Tens, Comp. Lumber Top chord 2x4 SP #2 A - B 39 0 B - C 67 -33 Bot chord 2x4 SP #2 Maximum Bot Chord Forces Per Ply (Ibs) Purlins Chords Tens.Comp. In lieu of structural panels or rigid ceiling use purlins B - D 0 0 to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 10 0.15 1.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Left bottom chord exposed to wind. **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field If 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. Convnnht n 2016 A-1 Roof Tmcsys — Ronrndnotion of this do ,mnnt in anv form Roof Tnic¢ac. ARMSCM1560B1L ( J3J, 1P r tuaa iyp. JACK arty I My 7 1 C SEAT PLATE REQ. 1 r5rt9 o l a 31 "1 Loading Criteria (psf) Wind Criteria Code / Misc Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES TCDL: 10.00 Speed: 160 mph TPI Std: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) EXP: B Kzt: NA Plate Type(s): Des Ld: 37.00 Mean Height: 25.00 ft WAVE NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 34 0.15 3.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design U/r IalLULU T 2596 M O LO r � N Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/deft L/# Gravity Non -Gravity VERT(LL): NA I Loc R+ / R- / Rh / Rw /U / RL VERT(CL): NA HORZ(LL): 0.001 D HORZ(TL): 0.001 D Creep Factor: 2.0 Max TC CSI: 0.389 Max BC GSI: 0.064 Max Web CSI: 0.000 Wgt: 11.2 Ibis VIEW Ver: 19.01.00A.0618.16 B 233 /- /- /179 /93 /109 D 43 !- /- /20 /- C 64 /- /- /34 /56 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A -B 39 0 B -C 29 -87 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B -D 0 0 *'WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. (:nnvrinht n 201a A-1 Ronf inlssps - Rpnrndnrlinn of this dnraimpnt. in — fnnn. is nrohihitad without the wn"pn npimissinn of A-1 Rnnf Tnissps. Jou UJJ ARMSCM 1560B1 L J3A T 6"5 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 30 0.09 2.65 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 1 I UJ, I yfre JACK 3X4(B1) eLy 1 rry 1 1 12 B r_ fi' U// IJ/LULU T SEAT PLATE REQ. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. 217" 12 N Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): -0.001 B HORZ(TL): 0.001 C Creep Factor: 2.0 Max TC CSI: 0.196 Max BC CSI: 0.064 Max Web CSI: 0.000 Wgt: 9.8 Ibs VIEW Ver: 19.01.00A.0618.16 3434 AI ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw /U / RL A 105 /- A /61 /20 /67 C 43 /- /- /20 /- /- B 76 /- /- /46 /67 A Wind reactions based on MWFRS A Brg Width = 3.8 Min Req = 1.5 C Brg Width = 1.5 Min Req = - B Brg Width = 1.5 Min Req = - Bearing A is a rigid surface. Bearing A requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. A - B 34 -96 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A -C 0 0 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. Cnnvnnht (0 2016 A-1 Ronf Tni.son – Renrtulnntion of this donument, in anv form ie nrohihited Win -t the.6ttnn —i -ion of A-1 Roof To—, aonI russ I russ type IllyPly 07/13/2020 ARMSCM1560BlL I J3P I JACK 2 1 ( 2490 IN T SEAT PLATE REQ. �--- 1'5"9 3' -1 Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria A Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/deft L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): NA Loc R+ ! R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): NA B 233 /- /- /215 198 /109 BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.000 D D 43 /- /- /58 /30 A EXP: B Kzt: NA Des Ld: 37.00 Plate Type(s): HORZ( TL )� 0.001 D - - /- C 64 /- 137 /55 /- Mean Height: 25.00 ft WAVE Creep Factor: 2.0 Wind reactions based on MWFRS NCBCLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0.346 B Br Width = 8.0 Min Re 1.5 g q = Load Duration: 1.25 BCDL: 4.2 psf " Max BC CSI: 0.065 D Brg Width = 1.5 Min Req = - Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2 C Brg Width = 1.5 Min Req = - C&C Dist a: 3.00 ft Max Web CSI: 0.000 Bearing B is a rigid surface. Loc. from endwall: Any Wgt: 11.2 lbs Bearing B requires a seat plate. GCpi: 0.18 Maximum Top Chord Forces Per Ply (Ibs) Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 I Chords Tens.Comp. Chords Tens. Comp. Lumber Top chord 2x4 SP #2 A -B 39 0 B -C 29 -93 Bot chord 2x4 SP #2 Maximum Bot Chord Forces Per Ply (Ibs) Purlins Chords Tens.Comp. In lieu of structural panels or rigid ceiling use purlins B - D 0 0 to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 34 0.15 3.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Left bottom chord exposed to wind. -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St, Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. Con mht n 2n16 A-1 Roof Tmsxos – Roorodnntinn of this do-mnnt in anv form. is nrohihited wilhnnt tho writtnn nr?noiscion of A-1 Roof Tmxsos. ARMSCM1560BlL J5 JACK 6y 1y L SEAT PLATE REQ. �--- 1'5"9 + 5' Loading Criteria (psq Wind Criteria Code / Misc Criteria Defl/CSI Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/deft L/# TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): NA BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): NA BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.004 D EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.008 D Des Ld: 37.00 Mean Height: 25.00 ft WAVE NCBCLL: 10.00 TCDL: 5.0 psf Creep Factor: 2.0 Load Duration: 1.25 BCDL: 4.2 psf Max TC CSI: 0.339 Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 Max BC CSI: 0.218 C&C Dist a: 3.00 ft Max Web CSI: 0.000 Loc. from endwall: not in 4.50 Wgt: 18.2 Ibs GCpi: 0.18 VIEW Ver: 19.01.00A.0618.16 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 58 0.15 5.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design 2599 .N ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL B 299 /- !- /213 /106 /161 D 77 /- /- /36 /- C 127 !- /- /75 /107 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A -B 39 0 B -C 57 -107 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B -D 0 0 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. r:nnvnnht n 201E A-1 Roar Tnisa – Renrnrinrfion of this daminnent in anv fnnn. is nrohihitnd without tha wn"nn nenni-inn of A-1 Rnnf Tnnua Il ARMSCM1560B1 L J5A JACKY�c 1 y 11y C SEAT PLATE REQ. �--- 1'5"9 4'1"7 2536 Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): NA Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): NA B 269 /- / /197 /99 /138 BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.002 D - - D 62 /- !- /29 !- /- EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.004 D C 101 /- /- /58 /85 /- Des Ld: 37.00 Mean Height: 25.00 ft WAVE Creep Factor: 2.0 Wind reactions based on MWFRS NCBCLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0.228 B Brg Width = 8.0 Min Req = 1.5 Load Duration: 1.25 " BCDL: 4.2 psf Max BC CSI: 0.142 D Brg Width = 1.5 Min Req = - Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2 C Brg Width = 1.5 Min Req = - C&C Dist a: 3.00 ft Max Web CSI: 0.000 Bearing B is a rigid surface. Loc. from endwall: not in 4.50 Wgt: 16.8 lbs Bearing B requires a seat plate. GCpi: 0.18 Maximum Top Chord Forces Per Ply (Ibs) Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 Chords Tens.Comp. Chords Tens. Comp. Lumber A - B 39 0 B - C 45 -89 Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Maximum Bot Chord Forces Per Ply (Ibs) Purlins Chords Tens.Comp. In lieu of structural panels or rigid ceiling use purlins B - D 0 0 to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 48 0.15 4.12 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in wdting by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. r:nnvrinht ct7 2016 AA Ronf Tmssns – R-rodurtinn of this d-timvntin anv fnrrn, is nrnhihit.d without tho written nnonieainn of A-1 Rnof Tntcsn.¢ arrry vrnor��cv ARMSCM1560BlL J5B JACa KiyPc ty (1 1 I ¢3437 3X4(8 1) n SEAT PLATE REQ. 1a 47"12 ---i Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): NA BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): NA BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.005 B EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.007 C Des Ld: 37.00 Mean Height: 25.00 ft WAVE NCBCLL: 10.00 TCDL: 5.0 psf Creep Factor: 2.0 Load Duration: 1.25 BCDL: 4.2 psf Max TC CSI: 0.372 Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 Max BC CSI: 0.210 C&C Dist a: 3.00 ft Max Web CSI: 0.000 Loc. from endwall: not in 4.50 Wgt: 15.4 lbs GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 54 0.09 4.65 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design M CO P N ♦ Maximum Reactions (Ibs) Gravity Loc R+ / R- / Rh Non -Gravity /Rw /U /RL A 181 /- /- /106 /40 /119 C 76 /- /- /37 /- B 133 /- /- /81 /114 /- Wind reactions based on MWFRS A Erg Width = 3.8 Min Req = 1.5 C Brg Width = 1.5 Min Req = - B Brg Width = 1.5 Min Req = - Bearing A is a rigid surface. Bearing A requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. A -B 59 -111 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A -C 0 0 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' forth. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI.1. The approval of the TDD and any field 488906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. Cnnvrinht n 2nia A-1 Rnnf Tni. c. _v - RPnrodurlinn of thio dnnjmenl in anv form. ie nmhihited tvilhnut the umitten nertniecinn of A-1 Rnnf Tniesa�. dooi cuss I russ I ype c ity I-ly 07/13/2020 ARMSCM1560BIL J5P I JACK 2 1 I 2493 T C SEAT PLATE REQ. VY9 - I 5' Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): NA BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): NA BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.004 D Des Ld: 37.00 EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.008 D Mean Height: 25.00 ft WAVE NCBCLL: 10.00 TCDL: 5.0 psf Creep Factor: 2.0 Load Duration: 1.25 BCDL: 4.2 psf Max TC CSI: 0.331 Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 Max BC CSI: 0.279 C&C Dist a: 3.00 ft Max Web CSI: 0.000 Loc. from endwall: not in 4.50 Wgt: 18.2 lbs GCpi: 0.18 VIEW Ver: 19.01.00A.0618.16 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 58 0.15 5.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Left bottom chord exposed to wind. ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL B 299 /- /- /276 /114 /161 D 77 /- /- /110 /58 /- C 127 /- /- /81 /105 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A -B 39 0 B -C 57 -118 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B -D 0 0 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field If 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. (:nnvriohf n 2n1a A-1 Rnnf Tni[.cac — Ranrntlnntinn of Ihia Annimvnf. in anv fnnn. iv nrnhihifnfl wilhnnl thn wriMan nnrmicsinn of A-1 Rnnf T.-, dou uss ARMSCM1560BlL J5P 9.1 I russ I ype JACK Cary Fly 2 1 1 C U1/1;i/LULU SEAT PLATE REQ. f -- VY9 -1-^ 5' 2493 Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/deft L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): NA Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): NA B 299 /_ /- /276 /114 /161 BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.004 D D 77 /- /- /110 /58 /- DesEXP: B Kzt: NA 37.00 Plate Type(s): HORZ TL 0.008 D ( ) C 127 /- /- /81 /105 A Mean Height: 25.00 ft WAVE Creep Factor: 2.0 Wind reactions based on MWFRS NCBCLLd: : 1 TCDL: 5.0 psf Max TC CSI: 0.331 B Brg Width = 8.0 Min Req = 1.5 Load Du on: Load Duration: 1.25 BCDL: 4.2 psf D Brg Width = 1.5 Min Req = - Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2 " Max BC CSI: 0.279 C Brg Width = 1.5 Min Req = - C&C Dist a: 3.00 ft Max Web CSI: 0.000 Bearing B is a rigid surface. Loc. from endwall: not in 4.50 Wgt: 18.2 lbs Bearing B requires a seat plate. GCpi: 0.18 Maximum Top Chord Forces Per Ply (Ibs) Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 Chords Tens.Comp. Chords Tens. Comp. Lumber Top chord 2x4 SP #2 A - B 39 0 B - C 57 -118 Bot chord 2x4 SP #2 Maximum Bot Chord Forces Per Ply (Ibs) Purlins Chords Tens.Comp. In lieu of structural panels or rigid ceiling use purlins B - D 0 0 to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 58 0.15 5.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Left bottom chord exposed to wind. ..WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any Feld 488906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. C: vnnht n 2n1a A-1 Ronf Tnis.% - – Renrnd,intinn of this domiment. in—f— Rnnf Tn10.Ces. JOU USS ARMSCM1560BlL J7 I FUSS Iype EJAC 9y 11y I U//l.5/1ZUZU C SEAT PLATE REQ. �— 1'5'9 1 7' Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): NA BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): NA BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HCRZ(LL): 0.014 D EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.027 D Des 37.00 Mean Height: 25.00 ft WAVE NCBCLL: 10.00 TCDL• 5.0 psf Creep Factor: 2.0 Load Duration: 1.25 BCDL: 4.2 psf Max TC CSI: 0.704 Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 Max BC CSI: 0.449 C&C Dist a: 3.00 ft Max Web CSI: 0.000 Loc. from endwall: not in 4.50 Wgt: 23.8 lbs GCpi: 0.18 VIEW Ver: 19.01.00A.0618.16 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.15 7.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design 2602 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 371 /- /- /254 /122 /213 D 111 !- !- /54 /- C 186 /- /- /112 /155 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A -B 39 0 B -C 83 -138 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B -D 0 0 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Krislam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. (:nnvrinht n 201E AA Roar Tnisse-S- R—odurtinn of this Anenmxnt in anv form. is nrohihiisd withnut thn wnnsn nermisshn of A-1 Rnnf Tnicsnc. ARMSCM1560BlL I J7C e,.„ r,N. EJAC 6y I1y 101 SEAT PLATE REQ. f --- 1'5"9 --1 27'10 -j- 4'4"6 �{ 3368 A 1 Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.120 F 684 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.222 F 370 240 B 371 /- t- /254 /122 /213 BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.050 G - - E 107 /- /- /54 /1 /- Des Ld:CL 37.00 EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.092 G D 184 I- /- /112 /150NCB/- Mean Height: 25.00 ft WAVE Creep Factor: 2.0 Wind reactions based on MWFRS ton: BCDL: 5.0 psf Max TC CSI: 0.669 B Brg Width = 8.0 Min Req = 1.5 Load Du: Load Duration: 1.25 " BCDL: 4.2 psf Max BC CSI: 0.418 E Brg Width = 1.5 Min Req = - Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2 D Brg Width = 1.5 Min Req = - C&C Dist a: 3.00 ft Max Web CSI: 0.206 Bearing B is a rigid surface. Loc. from endwall: not in 9.00 Wgt: 28.0 lbs Bearing B requires a seat plate. GCpi: 0.18 Maximum Top Chord Forces Per Ply (Ibs) Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 I Chords Tens.Comp. Chords Tens. Comp. Lumber Top chord 2x4 SP #2 A -B 39 0 C -D 82 -130 Bot chord 2x4 SP #2 B - C 0 -213 Webs 2x4 SP #3 Maximum Bot Chord Forces Per Ply (Ibs) Plating Notes Chords Tens.Comp. Chords Tens. Comp. All plates are 1.5X3 except as noted. B - F 98 -107 G - E 0 0 Purlins C - G 106 -89 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Maximum Web Forces Per Ply (Ibs) Chord Spacing(in oc) Start(ft) End(ft) Webs Tens.Comp. BC 30 0.15 2.49 BC 66 2.49 7.00 G - F 51 21 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -i. (', n n.ht n 201a A-7 in anv form. is nrohihited Wthnnf the? wditnn nnnnicainn of A-1 Ronf Tmtsnr, IARMSCM1560B1L RP r i uaa t yNc EJAC Ufty Yry U//lJ/LULU 5 1 C SEAT PLATE REQ. f —" 1'5"9 + 7, 2496 Loading Criteria (psfl Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): NA Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): NA B 371 /- /- /343 /135 /213 BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.014 D D 111 /- /- /161 /86 /- EXP: B Kzt: NA Des Ld:CL 37.00 Plate Type(s): HORZ(TL): 0.027 D C 186 /- /- /121 /152NCB/- Mean Height: 25.00 ft WAVE Creep Factor: 2.0 Wind reactions based on MWFRS : 1 TCDL: 5.0 psf Max TC CSI: 0.704 B Brg Width = 8.0 Min Req = 1.5 Load Du on: Load Duration: 1.25 BCDL: 4.2 psf " Max BC CSI: 0.594 D Brg Width = 1.5 Min Req = - Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2 C Brg Width = 1.5 Min Req = - C&C Dist a: 3.00 ft Max Web CSI: 0.000 Bearing B is a rigid surface. Loc. from endwall: not in 4.50 Wgt: 23.8 lbs Bearing B requires a seat plate. GCpi: 0.18 Maximum Top Chord Forces Per Ply (Ibs) Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 I Chords Tens.Comp. Chords Tens. Comp. Lumber Top chord 2x4 SP #2 A - B 39 0 B - C 83 -154 Bot chord 2x4 SP #2 Maximum Bot Chord Forces Per Ply (Ibs) Purlins Chords Tens.Comp. In lieu of structural panels or rigid ceiling use purlins B - D 0 0 to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.15 7.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Left bottom chord exposed to wind. **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Port Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. Convdnht n 2016 AA Roof Tn..,.,-- Renrod,intion of thii dmineentin anv toneis nrnhihited without the written nonniesinn of A-1 Roof Tmasac. ARMSCM1560B1L 11 UJJ IIUJA IyIJC VM01 VAL emery I rIy 1 1 15—�--- -- 3,3n9 1 — 2'0"1 --{ 12 B; 5X6 1112X4 C i - 5'10"9 I 57"1 p" 1 )E UIt 1014U4U T 901 2584 �f Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (lbs), or *=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.070 B 987 360 Loc R+ / R- / Rh / Rw /U / RL E* 76 /- /- /40 /16 /10 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.133 B 519 240 BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.027 B - - Wind reactions based on MWFRS Des Ld: 37.00 EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.052 B - - E Brg Width = 70.6 Min Req = - Mean Height: 25.00 ft WAVE Creep Factor: 2.0 Bearing A is a rigid surface. NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Max TC CSI: 0.379 Maximum Top Chord Forces Per Ply (Ibs) Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h Max BC CSI: 0.357 Chords Tens.Comp. Chords Tens. Comp. A - B 35 -109 B - C 54 -47 C&C Dist a: 3.00 ft Max Web CSI: 0.278 Loc. from endwall: not in 9.00 Wgt: 21.0 lbs GCpi: 0.18 Maximum Bot Chord Forces Per Ply (Ibs) VIEW Ver: 19.01.00A.0618.16 Wind Duration: 1.60 Chords Tens.Comp. Lumber A -D 83 -2 Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Purlins C - D 195 -149 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 3.88 5.88 BC 71 0.00 5.88 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See STD DETAILS for valley details. **WARNING** Please thoroughly review the "A-1 ROOF. TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT" form. verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. r:nnvnnht n 201e A-1 Rnnf Tn,c.,A, — Renrndnntion of thie dnnnment. in anv torn. is nrohihited withnnt the wdttnn nermicainn of A-1 Rnnf Tn­ auutruss truss type ARMSCM1560Bl L I VM02 I VAL ABV Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 7.88 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. g' 5 fly (1y I U//-13/ZuZU 7'3"10 C 7'10"9 i 5'10"4 F! '_ IV' 13 ---� Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes See STD DETAILS for valley details. Hi Defl/CSI Criteria PP Deflection in loc L/deft L/# VERT(LL): -0.032 C 999 361 VERT(CL): -0.062 C 999 241 HORZ(LL): -0.023 C - - HORZ(TL): 0.043 C Creep Factor: 2.0 Max TC CSI: 0.365 Max BC CSI: 0.304 Max Web CSI: 0.140 2581 ♦ Maximum Reactions (Ibs), or *=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw /U / RL F* 76 /- /- /46 /15 /17 Wind reactions based on MWFRS F Brg Width = 94.6 Min Req = - Bearing A is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A -B 71 -187 B -C 0 -48 Wgt: 28.0 lbs Maximum Bot Chord Forces Per Ply (Ibs) VIEW Ver: 19.01.00A.0618.16 Chords Tens.Comp. Chords Tens. Comp. A - E 224 -40 E - D 226 -44 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. B - E 348 -285 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineenn responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. C—nnht n 201E A-1 Rnnf Tn,ssns– R-roduntion of this dmi,mnntin anv foro. is nrnhihitod without thn wrift- nnnnission of A-1 Rnnf Tnissns. JOO ARMSCM1560Bl L I Fuss t russ I ype VM03 VAL -ea 1ty my I u111WZu[u 9'3"10 r. 9'10"9 r 5'10"4 'i 4'0"5 —� F 2578 Loading Criteria (ps0 Wind Criteria Code / Misc Criteria Defl/CSI Criteria A Maximum Reactions (lbs), or *=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.025 E 999 360 Loc R+ / R- / Rh / Rw /U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.048 E 999 240 F* 76 /- /- /46 /16 /17 BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.007 E - - Wind reactions based on MWFRS EXP: B Kzt: NA Des Ld: 37.00 Plate Type(s): HORZ(TL): 0.013E F Brg Width = 118 Min Req = - Mean Height: 25.00 ft WAVE Creep Factor: 2.0 Bearing A is a rigid surface. NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Max TC CSI: 0.409 Maximum Top Chord Forces Per Ply (Ibs) Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h Max BC CSI: 0.281 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a: 3.00 ft Max Web CSI: 0.092 A - B 76 -233 B - C 36 -77 Loc. from endwall: not in 9.00 Wgt: 40.6 lbs GCpi: 0.18 Maximum Bot Chord Forces Per Ply (Ibs) Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 Chords Tens.Comp. Chords Tens. Comp. Lumber A - E 258 52 E - D 265 -56 Top chord 2x4 SP #2 #2 Bot chord 2x4Maximum Webs 2x4 SP #33 Web Forces Per PI Ibs Y (Ibs) Webs Tens.Comp. Webs Tens. Comp. Purlins B - E 310 -353 C - D 128 -80 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 9.88 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes See STD DETAILS for valley details. `"WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bmcing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. Convrinht (c) 2nifi A-1 Rnnf Tnisses – Renrndn Ainn of this do-mentin nnv formis ornhihitsd without thn wditen nennksinn of AA Roof Tnisses. Ijuu ARMSCM1560Bl L 11ubb IIubtIype VM04 VAL -ea 1ty 11y ( Lill l6/LULU 11'3"10 r i 11'10"9 j— 5'10"4 610"5 2575 Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (lbs), or =PLF TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.020 E 999 360 Loc R+ / R- / Rh / Rw /U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.039 E 999 240 F` 76 /- /- /47 /16 /17 BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.005 E - - Wind reactions based on MWFRS EXP: B Kzt: NA Des 37.00 Plate Type(s): HORZ(TL): 0.010 E - - F Erg Width = 142 Min Req = - Mean Height: 25.00 ft WAVE Creep Factor: 2.0 Bearing A is a rigid surface. NCBCLL 10.00 L TCDL: 5.0 psf Load Duration: 1.25 BCDL: 4.2 psf Max TC CSI: 0.614 Maximum Top Chord Forces Per Ply (Ibs) Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h Max BC CSI: 0.349 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a: 3.00 ft Max Web CSI: 0.105 A - B 89 -284 B - C 64 -110 Loc. from endwall: not in 9.00 Wgt: 47.6 lbs GCpi: 0.18 Maximum Bot Chord Forces Per Ply (Ibs) Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 Chords Tens.Comp. Chords Tens. Comp. Lumber A - E 296 -63 E - D 305 68 Top chord 2x4 SP #2 #2 Bot chord 2x4Maximum Webs 2x4 SP #33 Web Forces Per PI Ibs Y (Ibs) Webs Tens.Comp. Webs Tens. Comp. Purlins B - E 353 -430 C - D 180 -144 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 11.88 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes See STD DETAILS for valley details. —WARNING"' Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 Sl. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1. C.—hriht n 2n1R A-1 Rnnf TmcsP_v - R—ndnrlinn of IN., doraimnnf. in anv fnrm. iz nrnhihifnd vithnnl thn wHftan nmrmicainn of AA Ronf T.-. JUNE 20, 2019 TYPICAL HIP / KING JACK CONNECTION I STDTL01 Y A MAX LOAD: 55 psf Roof Load, 175 mph, ASCE 7-10, Exp. B, C up to 60' Mean Roof Height and Exposure D up to 30' Mean Roof Height. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD, FORT PIERCE, FL 34946 772-409-1010 Attach End Jack's w/ (4) 16d Toe Nails @ TIC & (3) 16d Toe Nails @ BC Attach King Jack w/ (3) 16d Toe ,Nails @ TIC & BC ftach Corner Jack's t/ (2) 16d Toe Nails @ TIC & BC (Typ) Attach Corner Jack's w/ (2) 16d Toe Nails @ TIC & BC (Typ) Rama Pranav Kristam, P.E. # 88906 4451 St. Lucia Blvd. Suite 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 1 ALTERNATE GABLE END BRACING DETAIL I STDTL03 A-1 ROOF TRUSSES 4451 ST_ LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD 1' — 3' MAX. DIAG. BRACE AT 1/3 POINTS IF NEEDED IT IS THE RESPONSIBILITY OF THE BLDG. DESIGNER OR THE PROJECT ENGINEER/ARCHITECT TO DESIGN THE CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS. HORIZONTAL BRACE (SEE SECTION A -A) TRUSSSES R 24' O.C. 2X6 DIAGONAL BRACE SPACED 48' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d COMMONS. NAIL DIAGONAL BRACE TO PURLIN WITH TWO 16d NAILS. 2X4 PURLIN FASTENED TO FOUR TRUSSES WITH (2) — 16d NAILS EACH. FASTEN PURLIN TO BLOCKING W/ (2) — 16d NAILS (MIN.). ' PROVIDE 2X4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE \BRACE AND THE TWO TRUSSES ON \EITHER SIDE AS NOTED. TOENAIL \ BLOCKING TO TRUSSES WITH (2) — \ 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) — 10d COMMON WIRE NAILS. END WALL CEILING SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAIL SCHEDULE. METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL NAILING SCHEDULE: — FOR WIND SPEEDS 120 MPH (ASCE 7-9B, 02, 05), 150 MPH (ASCE 7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131' X 3') NAILS SPACED 6' O.C. — FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d (.131'X3') NAILS SPACED 6' O.C. (2X4 STUDS MINIMUM). STRUCTURAL I ( / GABLE ABLE TRUSS MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI BRACING METHODS SHOWN ON PAGE 1 ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIDE OF THE STRUCTURE. NOTE: THIS DETAIL IS TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED / STUDS. TRUSSES WITHOUT INLAYED STUDS ARE NOT ADDRESSED HERE. STANDARD GABLE / TRUSS UKAL TRUSS'. zan:� AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR VERTICAL/STUDS ONLY. Rama Pranav Kdstam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 12/23/19 PIGGY -BACK TRUSS STDTL04.1 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 PIGGY -BACK DETAIL (TYPICAL) 180 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE C, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00. OR... 160 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE D, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00. IMPORTANT NOTE: TOP CHORDS OF TRUSSES SUPPORTING PIGGY -BACK CAP TRUSSES MUST BE ADEQUATELY BRACED BY SHEATHING AND/ OR PURLINS. THE BUILDING ENGINEER OF RECORD SHALL PROVIDE DIAGONAL BRACING OR OTHER SUITABLE ANCHORAGE TO PERMANENTLY RESTRAIN PURLINS AND LATERAL BRACING FOR OUT OF PLANE LOADS OVER GABLE ENDS. MAXIMUM TRUSS SPACING IS NOT TO EXCEED 24" O.C. DETAIL IS NOT APPLICABLE IF CAP SUPPORTS ADDITIONAL LOADS SUCH AS CUPOLA, STEEPLE, CHIMNEY OR DRAG STRUT LOADS. **REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWINGS FOR PIGGY -BACK AND BASE TRUSS SPECIFICATIONS." PIGGY -BACK TRUSS. (REFER TO ACTUAL TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) 2'-0" MAX OPTION NO. 1 - TEE-LOK 3" x 8" TEE-LOK MULTI -USE CONNECTION PLATES SPACED AT 4'-0" O.C. MAX. PLATES SHALL BE PRESSED INTO PIGGY -BACK TRUSS AT 4'-0" O.C. STAGGERED FROM EACH FACE AND NAILED TO BASE TRUSS WITH 4 EACH 6d (1.5" X 0.099") NAILS IN EACH PLATE TO ACHEIVE MAXIMUM UPLIFT CAPACITY OF 377 LBS AT EACH 3" X 8" TEE-LOK MULTI -USE CONNECTION PLATE (MINIMUM OF 2 PLATES). OPTION NO.2 - APA RATED GUSSET: 8" x 8" x 0-7/16" (MIN.) APA RATED SHEATHING GUSSETS EACH FACE. ATTACH AT 8'-0" O.C. w/ 8 (EACH) 6d COMMON (0.1 13" x 2") NAILS PER GUSSET: 4 (EACH) AT CAP BOTTOM CHORD & 4 (EACH) AT BASE TRUSS TOP CHORD. GUSSETS MAY BE STAGGERED AT 4'-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION NO.3 - 2X4 VERTICAL WOOD SCAB: 2X4 SPF #2, FULL CHORD DEPTH SCABS AT EACH FACE. ATTACH AT 8'-0" O.C. w/6 (EACH) l Old BOX NAILS (0.128" x 3") PER SCAB: 3 (EACH) AT CAP BOTTOM CHORD AND 3 (EACH) AT BASE TRUSS TOP CHORD. SCABS MAY BE STAGGERED 4'-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION #1: TEE-LOK MULTI -USE CONNECTION PLATE. OPTION #2: APA RATED GUSSET. OPTION #3: 2X4 VERT. SCAB. ATTACH EACH PURLIN TO TOP CHORD OF BASE TRUSS. PURLIN & CONNECTIONS BY OTHERS. BASE TRUSS. (REFER TO TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) PURLINS SPACED ACCORDING TO MAX. SPACING OF TOP CHORD OF BASE TRUSS. SPACING IS NOT TO EXCEED 24" O.C. & PURLINS TO BE LOCATED AT JOINT OF EACH BASE TRUSS. ** IMPORTANT NOTE ** THIS DETAIL IS VALID ONLY FOR SINGLE PLY BASE TRUSSES SPACED AT 24" O.C. OR LESS. Rama Pranav Kristam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 JULY 17, 2017 1 TRUSSED VALLEY SET DETAIL - SHEATHED A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FOI GENERAL SPECIFICATIONS: STDTL05 1. NAIL SIZE = 3" X 0.131" = 10d 2. WOOD SCREW = 4.5" SDS25412 SIMPSON OR EQUIVALENT. 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER DETAIL "A". 5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS, 6. NAILING DONE PER NDS - 01. -E END, COMMON 3S, OR GIRDER TRUSS DETAIL A Rama Pranav Kristam, P.E. # 88906 4451 St. Lucie Blvd. Suite 201 Fort Pierce, FL 34946 TRUSS CRITERIA: SECURE VALLEY TRUSS WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05:146 MPH W/ ONE ROW OF 10d WIND DESIGN PER ASCE 7-10: 170 MPH NAILS 6" O.C. MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE C WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF ATTACH 2X4 CONTINUOUS #2 MAX SPACING = 24" O.C. (BASE AND VALLEY) SYP TO THE ROOF W/ TWO MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. SIMPSON SDS25412 (1/4" X 4.5') OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS, DETAIL A Rama Pranav Kristam, P.E. # 88906 4451 St. Lucie Blvd. Suite 201 Fort Pierce, FL 34946 FEBRUARY 5, 2018 ( TRUSSED VALLEY SET DETAIL ( STDTL06 GENERAL SPECIFICATIONS: AWWX A� 1. NAIL SIZE= 3"X 0.131" = 10d 2. WOOD SCREW = 3" SDS25300 SIMPSON OR EQUIVALENT. 3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE PER DETAIL "A" 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN DRAWINGS. 5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. A-1 ROOF TRUSSES 6. NAILING DONE PER NDS - 01. 4451 ST. LUCIE BLVD. GABLE END, COMMON FORT PIERCE, FL 34946 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C. TRUSS, OR GIRDER 772-A09-1010 TRUSS 7 SECURE W/( VALL YTMC RUA) I� II I tl II II II IIASE TRUSSES V 1— i n l L r.% (NO SHEATHING) N.T.S. GABLE END, COMMON TRUSS, OR GIRDER P F-12 VALLEY TRUSS TRUSS (TYPICAL) SEE DETAIL "A" BELOW (TYP.) Rama Pranev Kristam, P.E. # 88906 4451 St. Lucie Blvd. Suite 201 Fort Pierce, FL 34946 WIND DESIGN PER ASCE 7-96, ASCE 7-02, ASCE 7-05:146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE C WIND DURATION OF LOAD INCREASE: 1.60 ATTACH 2X4 CONTINUOUS #2 MAX TOP CHORD TOTAL LOAD = 50 PSF SYP TO THE ROOF W/ TWO MAX SPACING = 24" O.C. (BASE AND VALLEY) SIMPSON SDS25300 (1/4" X 3") MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS. Rama Pranev Kristam, P.E. # 88906 4451 St. Lucie Blvd. Suite 201 Fort Pierce, FL 34946 'JULY 17, 2017 I 1 1 ` (HIGH WIND VELOCITY) ^FL I STDTL07 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD, FORT PIERCE, FL 34946 772109.1010 ATTAC WIND DESIGN PER ASCE 7-98, ASCE 7-I WIND DESIGN PER ASCE 7-10: 170 MPF MAX MEAN ROOF HEIGHT = 30 FEET CATERGORY II BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREASE:' MAX TOP CHORD TOTAL LOAD = 50 PSF MAX SPACING = 24" O.C. (BASE AND VA SUPPORTING TRUSSES DIRECTLY UNG— -111 i I-- -U.. — DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2'- 10" ON AFFECTED TOP CHORDS. NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPF -S SPECIES LUMBER. FOR BEVELED BOTTOM CHORD, CLIP MAY BE APPLIED TO EITHER FACE. rCLIP MAY BE APPLIED TO THIS FACE NON -BEVELED I MAXIMUM 6/12 PT CHH TO A NON -BEVELED BOTTOM CHORD BOTTOM CHORD CLIP MUST BE APPLIED TO THIS FACE WHEN PITCH EXCEEDS 612 (MAXIMUM 1212 PITCH) Rama Pranav Kristam, P.E. d 88906 4451 St. Lucie Blvd. Suite 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 STANDARD GABLE END DETAIL TYPICAL 2X4 L -BRACE NAILED TO 2X4 VERTICALS W/lOd NAILS, 6' O.C. V ER1 STUD SECTION B -B TRUSS GEOMETRY AND CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. VERTICAL 2X6 SP OR SPF STUD#2 DIAGONAL DIAGONAL BRACE (4) - 16d 10d NAILS 16d NAILS BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. SPACED 6. O.C. (2) lOd NAILS INTO 2X6 2X6 SP OR SL'B SPF #2 2X4 SP OR SPF #2 TYPICAL HORIZONTAL 5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM BRACE NAILED TO AT 4'-0'D.C. 2X4 VERTICALS SECTION A -A W/(4) - 10d NAILS DIAGONAL BRACE 4' - 0' O.C. MAX. Imo® SEE INDIVIDUAL ENGINEERING DRAWINGS FOR TRUSS DESIGN CRITERIA. 12 PROVIDE 2X4 BLOCKING BETWEEN Q VARIES TO COMMON TRUSS THE FIRST TWO TRUSSES AS NOTED. TOENAIL BLOCKING TO TRUSSES * WITH (2) - 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d NAILS (4) Bd NAILS MINIMUM, ROOF B 3X4= PLYWOOD SHEATHING TO SHEATHING 2X4 STD SPF BLOCK * DIAGONAL BRACING ** L - BRACING REFER / REFER TO SECTION A -A TO SECTION B -B 24' MAX. (J f OT / / DIAGONAL (2) DIAGONAL BRACES AT 1.GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS. MINIMUM 10d 2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO 12' MAX. NAILS BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 1/3 POINTS 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG. ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF ' SL'B 4. ACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR BETTER WITH ONE ROW OF 10d NAILS SPACED 6' O.C. TRUSSES @ 24' O.C. 5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM / AT 4'-0'D.C. 3-8-10 6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN 2X6 DIAGONAL BRACE WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT SPACED 48' O.C. ATTACHED THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE _ TO VERTICAL WITH (4) - STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A) 16d NAILS, AND ATTACHED 7. GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240. TO BLOCKING WITH (5) B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. DIAG. BRACE 10d NAILS. S. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS 5.4-12 TRUSSES. IF NEEDED 2x4 SP #2 10. 10d AND 16d NAILS ARE 0.131'X3.0' AND 0.131'X3.5' COMMON WIRE NAILS HORIZONTAL BRACE RESPECTIVELY. (SEE SECTION A -A) 11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12 2X4 SP #2 BY SPIB/ALSC. 3.6.11 MINIMUM STUD STUD WITHOUT 2X4 DIAGONAL (2) DIAGONAL BRACES AT SIZE SPECIES SPACING BRACE L - BRACE BRACE 1/3 POINTS AND GRADE MAXIMUM STUD LENGTH 2X4 SP #31 STUD 12" O.C. 3-8-10 5.6.11 6.6.11 11.1-13 2X4 SP #31 STUD 1 16" O.C. 3-3.10 4-9-12 6-6-11 9-10.15 2X4 SP #31 STUD 24" O.C. 2.8-6 3.11-3 5.4-12 8.1-2 2x4 SP #2 12" O.C. 3-10.15 5.6.11 6-6-11 11-8-14 2X4 SP #2 16" O.C. 3.6.11 4-9-12 6-6-11 10.8.0 2X4 SP #2 24" O.C. 3-1.4 3-11-3 6-2.9 9-3.13 DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T -BRACE ATTACHED TO ONE EDGE. DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE WITH 10d NAILS G' O.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER 90% OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2. MAX MEAN ROOF HEIGHT = 30 FEET EXPOSURE B OR C - ASCE 7-10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING. DURATION OF LOAD INCREASE :1.60 CONNECTION OF BRACING IS BASED ON MWFRS. END WALL Rama Pranav Kristam, P,E. 488906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 T -BRACE / I—BRACE DETAIL FEBRUARY 17, 2017 WITH 2X BRACE ONLY STDTL09 NOTES: T—BRACING / I—BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING IS IMPRACTICAL. T—BRACE / I—BRACE MUST COVER 90% OF WEB LENGTH. THIS DETAIL NOT TO BE USED TO CONVERT T—BRACE / I—BRACE WEBS TO CONTINUOUS LATERAL BRACED WEBS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34846 772-409-1010 NAILING PATTERN T -BRACE SIZE NAIL SIZE NAIL SPACING 2X4 OR 2X6 OR 2X8 10d 6" O.C. NOTE: NAIL ALONG ENTIRE LENGTH OF T—BRACE / I—BRACE (ON TWO—PLY TRUSSES NAIL TO BOTH PLIES) NAILS SPACING BRACE SIZE FOR ONE -PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I—BRACE 2X6 2X6 T—BRACE 2X6 I—BRACE 2X8 2X8 T—BRACE 2X8 I—BRACE BRACE SIZE FOR TWO—PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I—BRACE 2X6 2X6 T—BRACE 2X6 I—BRACE 2X8 2X8 T—BRACE 2X8 I—BRACE T—BRACE / I—BRACE MUST BE SAME SPECIES AND GRADE (OR BETTER) AS WEB MEMBER. NAILS WEB NAILS I—BRACE NAILS WEB T—BRACE SECTION O E T A I L S_n1e Pranav Kristam, P.E. a 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 1 LATERAL BRACING RECOMMENDATIONS ( STDTL10 TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2X6 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY 8 TO 10 FEET ALONG A FLOOR TRUSS. ." NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY A-1 ROOF TRUSSES OF THE METHODS ILLUSTRATED BELOW. 4489 ST. LUCIE BLVD. FORT PIERCE, FL 34946 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE 772.409.9090 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENDS. INSERT WOOD SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (00 NOT USE METAL FRAMING ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS) ANCHOR TO ATTACH WEB WITH (3) - 10d SCAB WITH (3) - 10d TO TOP CHORD NAILS (0.131' X3') NAILS (0.131' X 3'). ATTACH TO VERTICAL NAILS WITH ( X3) BLOCKING BEHIND THE VERTICAL WEB IS RECOMMENDED WHILE NAILING THE STRONGBACK USE METAL FRAMING ANCHOR TO ATTACH TO BOTTOM CHORD TRUSS ATTACH TO VERTICAL WEB WITH (3) - 10d NAILS (0.131' X 3') ATTACH 2X4 VERTICAL TO FACE OF TRUSS. FASTEN TO TOP AND BOTTOM CHORD WITH (2) - 10d NAILS (0.131' X 7) IN EACH CHORD ATTACH TO VERTICAL SCAB WITH (3) - 10d NAILS (0.131' X 3') 2X6 4' - 0' WALL STRONGBACK (TYPICAL SPLICE) (BY OTHERS) ATTACH TO CHORD WITH (2) #12 X 3' WOOD SCREWS (0.216' DIA.) INSERT SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRDNGBACK (DO NOT USE DRYWALL TYPE SCREWS) THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT, DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0.131' X 3') EQUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) - 10d NAILS (0.131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL). BLOCKING (BY OTHERS) Rama Pranav Kristam, P.E. 488906 4451 St, Lucie Blvd, Suite 201 FEBRUARY 17,2017 1 LATERAL TOE -NAIL DETAIL I STDTLII A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34948 772-409-1010 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45° WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN). 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. TOE -NAIL SINGLE SHEAR VALUES PER NDS 2001 (LB/NAIL) DIA SP OF HF SPF SPF -S .131 88.0 80.6 69.9 68.4 59.7 o .135 93.5 85.6 74.2 72.6 63.4 J .162 108.8 99.6 86.4 84.5 73.8 F6 .128 74.2 67.9 58.9 57.6 50.3 0 .131 75.9 69.5 60.3 59.0 51.1 p J N .148 81.4 74.5 64.6 63.2 52.5 ri VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0.162' DIA. X 3.5') WITH SPF SPECIES BOTTOM CHORD FOR LOAD DURATION INCREASE OF 1.15: 3 (NAILS) X 64.5 (LB/NAIL) X 1.15 (DOL) = 291.5 LB MAXIMUM CAPACITY ANGLE MAY VARY FROM 30° TO 60° 45.00° THIS DETAIL IS ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELOW. VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY. SIDE VIEW (2X3) 2 NAILS I NEAR SIDE NEAR SIDE SIDE VIEW (2X4) 3 NAILS -I NEAR SIDE i NEARSIDE NEAR SIDE SIDE VIEW (2X3) 2 NAILS NEAR SIDE -I NEAR SIDE NEAR SIDE NEAR SIDE ANGLE MAY VARY FROM 30° TO 60° 45.00' 29 # 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 1 UPLIFT TOE -NAIL DETAIL I STDTL12 A-1 ROOF TRUSSES 4451 ST, LUCIE BLVD, FORT PIERCE, FL 34946 772409-1010 THIS DETAIL SHALL BE USED FOR A CONNECTION RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS. NOTES: TOE—NAIL WITHDRAWAL VALUES PER NDS 2005 (LB/NAIL) DIA. SP OF HF SPF SPF—S Lo .131 59 46 32 30 20 z J .135 60 48 33 30 20 .162 72 58 39 37 25 J _ 0 .128 54 42 28 27 19 z.131 Z Z O0 55 43 29 28 19 W .148 62 48 34 31 21 —I J N d � Z .120 51 39 27 26 17 0 Z .128 49 38 26 25 17 O .131 51 39 27 26 17 J .148 57 44 31 28 20 t+7 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30° WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION. VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0.162' DIA. X 3.5') WITH SPF SPECIES TOP PLATE FOR WIND DOL OF 1.33: 3 (NAILS) X 37 (LB/NAIL) X 1.33 (DOL FOR WIND) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND FOR WIND DOL OF 1.60: 3 (NAILS) X 37 (LB/NAIL) X 1.60 (DOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LBS (177 LBS) BUILDING DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION. **• USE (3) TOE -NAILS ON 2X4 BEARING WALL +*+� USE (4) TOE -NAILS ON 2X6 BEARING WALL NEAR SIDE FAR S) SIDE VIEW )E TOP PLATE OF WALL VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY (L NAIL NAIL Rama Pranev Kristam, RE. 88906 END VIEW 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 TYP 2x2 NAILER ATTACHMENT I STDTL13 2x2 NAILER ATTACHMENT GENERAL SPECIFICATIONS T' •' LOAD: 55 • '•• •.• 170 • ASCE 7-10, 29'-0" Mean Height, Exp. B, C • D. 1.0x4 Rama Pranav Kdstam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 �Ort fierce, 1- L J4Sb April 11, 2016 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 TYPICAL ALTERNATE BRACING DETAIL FO EXTERIOR FLAT GIRDER TRUSS (4) 12d UPLIFT CONNECTION (SEE ROOF TRUSS) 12 VARIES STDTL14 (4) 12d MAX 3011(21-611) 2x6 #2 SP (Both Faces) 2411 o.c. Rams Pranav Kristam, P.E. # 88906 4451 St. Lucie Blvd. Suite 201 Fort Pierce, FL 34946 f FEBRUARY 17, 2017 I STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND I STDTL15 DAMAGED OR MISSING CHORD SPLICE PLATES A-1 ROOF TRUSSES 4451 ST, LUCIE BLVD, FORT PIERCE, FL 34946 772409-1010 TOTAL NUMBER OF NAILS EACH SIDE OF BREAK * X (INCHES) MAXIMUM FORCE (LBS) 1S% LOAD DURATION SP OF SPF HF 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 20 30 24" 1706 2559 1561 2342 1320 1980 1352 2028 26 39 30" 2194 3291 2007 3011 1697 2546 1738 2608 32 48 36" 2681 4022 2454 3681 2074 3111 2125 3187 38 57 42" 3169 4754 2900 4350 2451 3677 2511 3767 44 66 48" 3657 5485 3346 5019 2829 4243 2898 4347 DIVIDE EQUALLY FRONT AND BACK ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (.131' DIA. X 3'). STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' D.C. SPACING IN THE MAIN MEMBER. USE A MIN. 3' MEMBER END DISTANCE. THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS) THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C TRUSS CONFIGURATION AND BREAK LOCATIONS FOR ILLUSTRATIONS ONLY THE LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL TO THE REQUIRED X DIMENSION FROM ANY PERIMETER BREAK OR HEEL JOINT AND A MINIMUM OF S" FROM ANY INTERIOR JOINT (SEE SKETCH ABOVE). DO NOT USE REPAIR FOR JOINT SPLICES NOTES: 1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. 2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HELD IN PLACE DURING APPLICATION OF REPAIR. 3. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. anav Kristam, P.E. 5. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY. Rama Pr#avKri 6. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS. 4451 St. Lucie Blvd, Suite 201 FEBRUARY 17, 2017 1 SCAB APPLIED OVERHANGS I STDTLI6 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 TRUSS CRITERIA: LOADING: 40-10-0-10 DURATION FACTOR: 1.15 SPACING: 24' O.C. TOP CHORD: 2X4 OR 2X6 PITCH: 4/12 - 12/12 HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL END BEARING CONDITION 111111*3 1. ATTACH 2X -SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS WITH TWO ROWS OF 10d COMMON WIRE NAILS (.14B' DIA. X 3') SPACED 6' O.C. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 2X SC NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED WHEN OVERHANG HAS BEEN BROKEN OFF. IMPORTANT THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24' D.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD LOADS NOT EXCEEDING 50 PSF. TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY. REFER TO INDIVIDUAL TRUSS DESIGN FOR PLATE SIZES AND LUMBER GRADESI Rama Pranav Kdstam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946