HomeMy WebLinkAboutAPPROVED DM CLASS 1000 - 27499.1 (HVHZ APPROVED) 4/10/2020 Florida Building Code Online
a4
m
Y
afi "
BCIS Home 1 Log in I User Registration I Hot Topics ' Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map i Links I Search
:product Approval j� r aWSERt Public User -
Product„ ,-Approval Menu>product or Application Search>App€ication List>Application Detail
s FL# FL27499 R1 ll
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Dynamic Metals
Address/Phone/Email 3201 SE Dominica Terace
Stuart, FL 34997
(772) 872-8030
juan@dynamicmetal.net
Authorized Signature Lara 3esus
juan@dynamicmetai.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Scott Wolters
Evaluation Report
Florida License PE-62354
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Lucas A.Turner, P.E., M$A
Validation Checklist- Hardcopy Received
Certificate of Independence FL274 9 R1 COI Dyn COl.pdf
References!Standard and Year(of Standard) Standard Year
TAS 100 1995
TAS 110 2003
TAS 125 2003
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6B4Kr53X7m7RLNDTr%2fv7QaQ%3d°/a... 1/4
4110/2020 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 02/22/2019
Date Validated 08/29/2019
Date Pending FBC Approval 08/30/2019
Date Approved 10/15/2019
Summary of Products
.....
FL# Modei,Number or Name Description
_ .... , ............. .................---....,.,.w ...
27499.1 DM Class 1000 1" Nailstrip 26 Ga. galvalume coated steel roof panel, 16"wide,with 1"
snap fit seams I
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes ; FL27499 R1 11 NSSI6HZ,pdf
I Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A i Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Limits of Use. Ft27499 R# AF C3M Evall.pdf
Created by Independent Third Party:Yes
.
-- _. . .�
... ........ .__ . - -. ----—,
27499,2 DM Class 1000 1" Nailstrip, j.032 Aluminum roof panel, 16"wide, with 1"snap fit seams.
Limits of Use — � installation Instructions ^'—
Approved for use in HVHZ:Yes FL27499 R1 11 NSAI6HZ,pdf
Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports 1
Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Eval2.pdf 3(
Created by Independent Third Party: Yes
27499 3 DM Class 1050 1 i 2" Nailstn seams.iuminum Roof Panel 19'Wide,with 1,,,,1/2 __
t.... _—__.__ ._ _ _
_ _
/ P 1/2 snap fit
.-- ----- _. _.�__.._.., _.1_._.._.,.___ -.................._ ..
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL27499 R1 II NSAI9HZ,pdf
Approved for use outside HVHZ:Yes Verified By: Scott Wolters, P.E. FLPE# 62354
Impact Resistant: N/A Created by Independent Third Pasty: Yes
Design Pressure. N/A Evaluation Reports
Other: Please see Eva) report for Limits of Use. FL27499 RI AE DM Eval1pdf
Created by Independent Third Party:Yes
T ..... ..-----. _. m... ...., _..._._......... ....,_.._.... .. —_.., _ _.._.. ..._... .
27499.4 DM Class 1050 1 1/2" Nailstrip 721/12"
Ga, Galvalume coated steel roof panel, 19"wide,with
snap fit seams
Limits of Use Installation Instructions
--i
Approved for use in HVHZ:Yes FL27499_R1. 1I NSSI9HZ.pdf
Approved for use outside HVHZ., Yes Verified By: Scott Wolters, RE. FLPE# 62354
Impact Resistant, N/A Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Eva14.pdf
Created by Independent Third Party:Yes
...._.._._...____........_. _..................._............................ ,032 Aluminum roof panel, 20"wide with 1 1/2"Sti,..., ............._ ..�
27499.5 DM Class 1500 1 1/2" Mechanical anding
Seam Jseams.
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL27499 R1 II 1SMSA20HZ.pdf
Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A III Evaluation Reports
Other: Please see Eval report for Limits of Use. FL27499 R1 AE QM Eval5.pdf
Created by Independent Third Party: Yes
....... ........ ......................................- - ..... — .,__ .---- ... _. ....,.
27499.6 DM Class 1500 1 1/2" Mechanical 16 oz, Copper roof panel, 16"wide, with 1 1/2"standing
Seam seams,
Limits of Use Installation Instructions -�
Approved for use in HVHZ:Yes FL27499 R1 II 15MSCHZ.pdf
Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure. N/A Evaluation Reports
Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Eva16.pdf
Created by Independent Third Party: Yes
_. .. ....,.
27499.7 DM Class 1500 1 1/2" Mechanical 26 Ga, galvalume coated steel roof panel, 16"wide, with 1 1/2"I
Seam standing seams,
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL27499 R1 11 15M551626HZ pdf
Approved for use outside HVHZ;Yes Verified By: Scott Wolters 62354
https:/Iwww.floridabuiiding.orglpr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6B4Kr53X7m7RLN DTr%2fv7QaQ°/u3ti%... 2/4
OIu,TERS ENGINEERING
ENGTNEERTNG,DRAFTING, CONSULTING
15211 97th Road N
West Palm Beach,FL 33412
PNFx:(561)225-19N
PRODUCT EVALUATION
(FOR HVHZ APPROVED PRODUCT)
PRODUCT: DM CLASS 1000 26 GA. GALVALUME 1" NAILSTRIP 16"WIDE
ROOF PANEL (F'LPA#27499,1)
MANUFACTURER: DYNAMIC METALS, LLC
340 PIKE ROAD
WEST PALM BEACH, FL 33411
To all concerned,
The DM Class 1000 Series 26 Ga, Galvalume 1" Nailstrip 16"Wide Roof Panel, manufactured by Dynamic
Metals LLC, is a non-structural galvalume coaled Fluropon painted steel roof panel (50 ksi min) that meets the
requirements of Sections 1507A and 1518.9 of the 61h Edition (2017) Florida Building Code. The panel has been
tested per TAS 100 and TAS 125 by lntertek with results shown in test reports G3443.40-450-44 and G3443.14-
450-44, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004-
02-01 and VLS-005-02-01.
Technical Documentation:
1. Drawing°NSS16-HZ"dated 8/15/19, signed and sealed by Scott Wolters, PE,
2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and
by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE,
3. Supplemental Calculations to support"NSS16-HZ" drawing, signed and sealed by Scott Walters, PE,
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61G20-3,005
(4). Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements of the 61h Edition(2017) Florida Building Code generally, and chapter 15 specifically, including the
HVHZ provisions.
Limitations: This panel is approved for use inside and outside of the HVHZ.
Overall Limitations: Maximum Panel Width: 16" (nominal)
Fastener Spacing across panel: 16" (at Nailstrip)
(Panels overlap with malelfemale snap fit)
Min. Slope: HVHZ: 2712"
Non-HVHZ; '/z712" (with Lap Sealant)
3"112" (no Lap Sealant in Field Zone)
5 ICI T%IN!1AFAC-r FF55fMf CIUKTAINWA,L5, lMNPOW5
Field Perimeter& Corner
Installation _ Installation
Max. Design Pressure: -116 psf -176 psf
Fastener Spacing: 3" From Ends, 6" Max. O.C. 3" From [ends, 6" Max. O.C.
Min Panel Fasteners: #10x1" Panclip Fasteners #10x1" Panclip Fasteners
Panei Sealant: Continuous bead of Geocel 2300
or 2320 at Nailstrip side of seam
Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the fire barrier within the assembly. (See note#2 below)
Note: Outside of the HVI-1Z, 1" round plastic caps may be used to prevent
galvanic reactions.
Underlay Minimum ASTM D 226 Type II with 4"overlaps and 6"end-laps, anchored
with 12 Ga, x 1 1/" galvanized roof nails with 32 Ga. Tin caps spaced 6"
O.C. in rows at the perimeter, at overlaps, and two intermediate rows
staggered and spaced 12" O.C.
(or)
Any underlayment with a valid FLPA or Miami-Dade NOA
Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent
galvanic reactions.
Minimum Substrate: ''/2' (15/32" min) 4-ply CDX Plywood,nailed to 2x rafters spaced 24"max.
O,C, with 8d ring-shank nails spaced 4"O.C.
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or
1515.2.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation,
4. Rational analysis, provided by a Florida licensed Arch itecUE nginee r
per FAS 61 G20.3.005(e), may be used for project specific approval by
the local authorities having jurisdiction.
5. All panels shall be permanently labeled with the manfacturer's name
and/or logo, and the following statement, "Dynamic Metals
FL#27499.1, DM Class 1000",
Sp Cip� iZING iN IAt11 KfC� 515(AWCW AiNWAA,5,5TOVFFFONt5, & WINOOWS
Panel FarrqLnE- These panels may be jobsite roll formed with the following Dynamic Metals machines, per
approval of 3rd party QA provider, to the dimensions shown on Drawing NSS1 6-HZ:
SSQ-6800617 SSQ-5150216 SSO-6810617
SSQ-6690517 SSQ-4560615 SSQ-8681118
5VC-0490718 5VC-0360516 5VC-0521218
Re-Ropfirij, The DM Class 1000 Series 26 Ga, Galvalume I"Nailstrip 16"Wide Roof Panel
may be Installed over a single layer of existing asphalt shingles, provide the existing roof
meets the requirements of Section 1521 (HVHZ)or Section 1511 (outside of HVHZ)of the
Florida Building Code.
.. ......................
If you have any questions or need more information concerning this approval please contact me.
waz
Thank you, C'O
No 62354
Seott 0*"e ors -'a,
11W
FL PE# 62354 STATE oF
0 0
AUG I 7M9
NA i-
L
" Tr0AJL UNI-6 N
:$8,Va R 3taF9 f aMS SS S:,Nd
ate`a3,Y,#11:;afY 5§'):€
aau�rYauruef r �°9 "€I2 � a Diu
>°;StriY i'
-00
d "
E ' �
C ,�
t3� 0 .
LLI
uj
LL
CD
cm
d
E
a
y ,,..
i