HomeMy WebLinkAboutEvaluation Report; TRI-BUILT Roof Underlayments�4 f
" ERD
TRINITY
EVALUATIONREP_ORT
TRI-BUILT Matei:ials Gn
PO Box 70
Rutherford, NJ 07070
(800) 516-1485
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
.'OXFORD, CT 06478
(203) 262-9245
FU6048-R6
Date of Issuance:10/25/2012
Revision 6: 09/25/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be In accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity ERD 'requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official. _
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
'-., s;,;,•„•�-.,,���
—••-- •• yam••.. •�•........�wv, rwrruu uw+nrvu�os P.E. on09/25/2017. This does not serve asanelectronlcalty'algned
CERTIFICATION OF INDEPENDENCE: document
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING COMPONENT EVALUATION:
I. SCOPE:
A TRiNIIY, ERA
Product Category: Roofing
Sub -Category: Underlayrfient
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the 61h Edition (2017) Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /
Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Resistance
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1504.6
Accelerated Weathering
ASTM G155
2005 -
1507.2.4 / 1507.1.1,1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012 (04-12)
2012
3. REFERENCES:
kni4i
Examination
Reference,
Date
ERD (TST6049)
Physical Properties
S40540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties
S40540.11.13
11/19/2013
ERD (TST6049)
Physical Properties
S40540.03.14
03/26/2014
ERD (TST6049)
Physical Properties
S44870.04.14-2
04/02/2014
ERD (TST6049)
Physical Properties
S44870.04.14-3
04/02/2014
ERD (TST6049)
Physical Properties
S44870.04.14-1
04/10/2014
ERD (TST6049J_ _
Physical Properties
S44870.04.14-4----
04/10/2014
ERD (TST6049)
Physical Properties
S43530.02.14-1-R3
05/14/2014
ERD (TST6049)
Physical Properties
S43530.05.14
05/28/2014
ERD (TST6049)
Physical Properties
S40540.10.14
10/31/2014
ERD (TST6049)
Physical Properties
SC7645.02.15
02/13/2015
ERD (TST6049-)_
Accelerated Weathering
SC8520.04.15 —
05/27/2015
ERD (TST6049)
Wind Resistance
SC14045.05.17-R1
06/07/2017
UL, LLC. (QUA9625)
Quality Control
Multiple -Listing R16814
12/10/2015
UL, LLC. (QUA9625)
Quality Control
Service Confirmation
Exp. 07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced,
sand -surfaced, SBS
--- --modifiedlitumen roof-anderlay_ment, Witt► a36-inch sheetwidth; meets AST— D1970.
—
4.2 Tri-Built S/A HT TU Underlayment is a self -adhering,
non -woven polyester fabric surfaced, SBS modified
`itumen rocif un eriayment; rrreets ASTM-UI970 an
pri .
4.3 Tri-Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS
modified bitumen roof underlayment; meets ASTM D1970.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report, refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, I.I.C. Evaluation Report A42960.30.12-R6
Certijkate of Author&atlon #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL36048-R6
TRI-BUILT Roof Underlayments; (800) 516i1485 Revision 6:09/25J2017
Page 2 of 6
TRINITY I ERD
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable -Roof Covers:
t
T ABLE t1. RooF
CbvER"OPT10NS3
a a
w 4
- - - "- -
.ry
-x
Underlayment
Asphalt
p
Nall -On Tile
Foam -On Tile
Metal
Wood Shakes
Slate
Shingles
=
& Shingles
TTri-Built Sand-R SA Shingle
Underlayment
Yes
No
No
No
Yes
Yes
r Trl-Built S/A HT TU
Yes
i' Underla men
y
es
es - - -.-
See 5.5.1
( Yes
Yes
Yes
Tri-Built Smooth HT S/,A
'
�
Underlayment
Yes
No
No
Yes
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
TABLE 1A7 ALLOWABLE TILE Albk6` E UNDERLAYIVIENT COMBINATIONS
_Adhesive
`• Florida Product Approval
Underlayments
ICP Adhesives Polyset® AH40
= FLti332_
: Tri-Built S/A HT TU Underlayment
Dow TileBond'"d
FL22525
_ -
Tri-Built S/A HT TL Underlayment_
5.6 Allowable Substrates:
5.6.1 -Direct-Bond to Deck:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC
recommends priming the deck if the final/roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or
OSB prior to installation of the self -adhering underlayment.
5.6.2 Bond-to,insulation:
Tri-Built Sand-R SA Shingle_UnderlaftOn ~, TriBuilt S/A_HT TU Underlayment or-Tri-Built Smooth HT-S/A - -
--- - - Underlayment-applied-to — - - ---
➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in accordance with FM 4474, Appendix D or TAS 114, Appendix J.
s Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6
Certiflcate of Authorkatlon #9503 6t" EDITION (2017) F8C NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (600) 516-1485 Revision 6: 09/25/2017
Page 3 of 6
r 1
1 TRINITY I ERD
5.6.3 Bond to.MechanicaIIVAttached Base La ►+er:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ ASTM D226, Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on tile systems (Tri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-
12).
5.6.4 Wind Resistance_for..Underlayment-Systems In Foam -On Tile Aaollc_atio_ns; FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to directideck
underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile
applications. Maximum Design Pressure is the result of testing for wind Ibad resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or
FBC 1609 for determination of design wind pressures.
#1 Maximum Design -Pressure =--410;iisf:
Deck:
Min. 15/32-inch piywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer:
(Optional) ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered.
#2 Maximum Desisn Pressure = -67.5 psf:
Deck:
Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer:
Soprema Elastocol 600c
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered.
#3 ,Maximum D_esiAn Pressure =-150.01isf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand_
-�� r_oller and/or weighTed roller to ensure_ _ there are_ no voids�_and_ensure:fhere_ are no--
voids/bridging at side and end -laps.
essure =_- s :
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three,
equally spaced rows in the center of the sheet.
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered.
Exterior Research and Design, U.C. Evaluation Report A42960.10.12-R6
Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVH2 EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516'-1485 Revision 6: 09/25/2017
Page 4 of 6
t V
B
`,.- `TRINITYI ERD
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 ,.Exposure Limitations:
Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation.
5.8 Tile-SH00aee-Limitations ftAS 101l er FRSA/TRI A"0ril 2012-104-12 ►':
When loading roof tiles on the underlayment in direct deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
TABLE 2 , TILE SLIPPAGE LIMITATIONS FOR i71RECi-DECK
TILE, INSTALLATIONS-.
Underlayment
Tile Profile
Staging Method
M S' iome m r
Fiat _ _ `
_Max. 10-tile stack - - _ - _
6:12
Lugged. - _
Max.16-tile stack
- 5:12
Max.10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high
6:12
on slo :,: shown below)= _
r
I,
Tri-Built S/A HT TU
Underlayment
-
Lugged
,' s
Exterior Research and Design, U.C.
Certijkate of Authorization #9503 GP EDITION (2017) FBC NON-HVHZ EVALUATION
TRI-BUILT Roof Underlayments; (800) 516-2495
Evaluation Report A42960.10.12-116
FL16048-R6
Revision 6: 09/25/2017
Page 5 of 6
_' TRINITY I ERD
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC
published installation requirements subject to the Limitations set forth in Section S herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable). Q
6.3 Tri-Built.Sand-R SA Shlriele Underlaviinent. Tri-Built VA HT TU_Underlayment or Tri-Built-Smooth HT S/A
-
6.3.1 Shall be Installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1S07.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile applications:
While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with
TRI-BUILT Materials Group, LLC requirements.
When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the
overlap area at the top of the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Anpiications ftri-Built S/A HT TU Underlavment onlyl
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged' in a manner that prevents the slippage and/or damage to the
underlayment.--See Table-2-herein,-and TRI-BUILT Materi coup; LLC published requirements for -tile
--
'. �iit mm PE-RMIT-REQUIREMENTS.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
S. MANUFACTURING PLANTS:
Gulfport, MS
9. QUALITY ASSURANCE ENTITY:
UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-R6
Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments;1800) S16-148S Revision 6: 09/25/2017
Page 6 of 6