Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: WYNNE THE W INDSOR IMPACT BuilderName: WYNNE. DEVELOPMENT Street: 3 C1 Q oS Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, PermitNumber: Owner: Jurisdiction: DesignLocation: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types _(1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Int Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208:00 ft2 3. Numberof units, if multiple family 1 c. N/A R= ft2. 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1783.0 sqft.) Insulation Area a. UnderAttic (Vented) R=30.0. 1753.00 ft2 6. Conditioned floor area above grade (ft2) 1753 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditionedfloorareabelowgrade(ft2) 0 c. R= ft2 11. Ducts R ft2 7.. Windows(151.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor: Sgl, U=1.04 111.36 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: AreaWeightedAverageOverhangDepth: 2.850 ft. Area Weighted Average SHGC: 0.285 14. Hot water systems 8. Floor Types (1753.0 sqft.) Insulation Area a. Electric Cap:. 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features EF:0.970 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 52.17 Glass/Floor Area: 0.086 PASS ASS Total Baseline Loads: 53.92 I hereby certify that the plans and specifications covered by Review of the plans and V* this calculation are in compliance with the Florida Energy Code. specifications covered by this calculation indicates ► compliance �,, with the Florida Energy Code. PREPAR�Q 13Y' - ; Before construction is completed p DATE: this building will be inspected for ._ compliance with Section 553:908 hereby certify that this building, as desi is in compliance Florida Statutes. With the Florida Energ Code.fly OWNER/A BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies a's certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with. R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5:00MII3 FOR F Py CODE CO, MPLIANCE ST. LUCIE�+COUNTY 4/21 /2020 10:04 AM EnergyGauge® USA 6:0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017)-Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY, CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: StreetAddress Building Type: User ConditionedArea: 1753 Lot# OwnerName: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst.Case: Yes PlatB.00k: BuilderName: WYNNE DEVELOPMENT RotateAngle: 0 Street: Permit Office: ST. LUCIE COUNTY CrossVentilation: No County:. St. Lucie Jurisdiction:. Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Single-family. FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design DailyTemp V Design Location TMY Site 97.5 % 2.5 % Winter Summer DegreeDays Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI. 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 140.24 SPACES. Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes ' Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0' 1 1 Yes Yes Yes 7 DINING/GREAT.RO 588 4704 No 2 1. Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1. Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER, 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3. 169 1352 No 0 1 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area- JoistR-Value Tile Wood Carpet 1 Slab-On-GradeEdge Insulation MASTER BEDRO 37 ft 0 224 ft2 ____ 0 1 0 2Slab-On-GradeEdge Insulation WIC 1 ft 0 63ft? ____ 0 1 0 3 Slab-On-GradeEdgeInsulation MASTER BATH 8 ft 0 56 W ____ 0 1 0 4Slab-On-GradeEdge lnsulation M. BATH 7ft 0 61 ft2 ____ 0 1 0 5Slab-On-GradeEdge Insulation LAUDRY 1 ft 0 36ft2 ____ 0 1 0 4/21 /202010:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space" Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 6Slab-On-Grade Edge Insulation BEDROOM 2 12 ft 0 180 ft2 ____ 0 1 0 7Slab-On-Grade Edge Insulation DINING/GREAT 50ft 0 588ft2 ____ 0 1 0. 8Slab-On-Grade Edge Insulation KITCHEN lift 0 209ft2 ____ 0 1 0 9 Slab -On -Grade Edge Insulation BATH 5 ft 0 50 ft2 ____ 0 1 0 10SIab-On-Grade Edge Insulation HALL 1 ft 0 25ft2 ____ 0 1 0 11SIab-On-Grade Edge Insulation FOYER 9 ft 0 92 ft2 ____ 0 1 0 12SIab-On-GradeEdge Insulation BEDROOM 3 14 ft 0 169 ft2 ____ 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt. Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft2 Light N 0.4 No 0.9 No 0 18.4 ATTIC. V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # CeilingType Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic(Vented) MASTER BEDRO 30 Blown 224ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63ft2 0.1 Wood 3 UnderAttic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under-AttlQ(Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 Under•Attic(Vented) LAUDRY 30 Blown 36ft2 0.1 Wood 6 UnderAttic(Vented) BEDROOM 30 Blown 180ft2 0.1 Wood 7 UnderAttic(Vented) DINING/GREAT 30 _ Blown 588ft2 0.1 Wood 8 UnderAttic(Vented) KITCHEN 30 Blown 209ft2 0.1 Wood 9 UnderAttic(Vented) BATH 30 Blown 50ft2 0.1 Wood 10 UnderAttic(Vented) HALL 30 Blown 25ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92ft2 0.1 Wood 12 UnderAttic(Vented) BEDROOM 30 Blown 169112 0.1 Wood 13 Knee Wall (Vented) DINING/GREAT 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Cavity Width Space Height Sheathing Framing Solar Below 1 E Exterior Concrete Block- Int InsuMASTER BE 4.1 16 0 8 0 12&0 ft2 0 0 0.3 0 2 W Exterior Concrete Block- Int InsuMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 3 S Exterior Concrete Block- Int InsuMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0 4/21 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - F[aRes20l 7 FBC 6th Edition (2017) Compliant Software . Page 3 of 6 FORMR4.05-2017 INPUT SUMMARY CHECKLIST REPORT WALLS - Adjacent Space Cavity Width Height Sheathing Framing Solar Below 4 E Exterior Concrete Block- Int InsuMASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 5 E Exterior Concrete Block - Int Insul M. BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 6 E Exterior Concrete Block - Int InsuBEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 7 S Exterior Concrete Block- Int InsuDINING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.3 0 _ 8 W Exterior Concrete Block- Int InsuDINING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.3 0 _ 9 W Exterior Concrete Block- Int Insul KITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0 10 E Exterior Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.3 0 _11 N Exterior Concrete Block- Int insul .FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 12 N Exterior Concrete Block- Int Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 13 W Exterior Concrete Block- Int InsuBEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0 14 N Exterior Concrete Block - Int InsuBEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 _15 N Garage Frame -Wood BEDROOM 3 11 26 8 208.0ft2 0.23 0.3 0 DOORS # Ornt DoorType. Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated FOYER None .32 3 3 6 8 21.7 ft WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp , Area Depth Separation IntShade Screening 1 'S 3 Metal Low-ESingle Yes 1.04 0.29 N 32.4 ft2 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior5 2 E 5 Metal Low-ESingle Yes 1.04 0.29 N- 6.9 ft2 1 ft 0 in 1 ft 5 in None None 3 E 6 Metal Low-ESingle Yes 1.04 0.29 N 16.2 ft2 1 ft 0 in 1 ft 5 in None None 4 S 7 Metal Low-ESingle Yes 1.04 0.29 N 39.8 ft2 1 ft 0 in 1 ft 5 in None None 5 W 8 Metal Low-ESingle Yes 1.11 0.27 N 40.0 ft2 8 ft 0 in 1 ft 5 in None None 6 W 13 Metal Low-ESingle Yes 1.04 0.29 N 16.2 ft2 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior5 GARAGE # FloorArea CeilingArea Exposed Waii Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000254 1168.7 64.16 120.66 .0881 5 4/21 /202010:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R4115-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8 kBtu/hr _ 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 CentralUnit/ Split Single SEER:15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # . System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # CompanyName System Model# CollectorModel# Area Volume FEF None None ft2 DUCTS -- Supply---- ---- Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area LeakageType Handier TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 Attic 55 ftz . DefaultLeakage Attic (Default) c(Default) c 1 1 TEMPERATURES ProgramableThermostat: Y Ceiling Fans: Conlin Jan Feb Mar Heating Jan Feb NMar A r E Apr Ma Jun Jul May Jun Jul I Auge AuSep Oct Nov Oct ] Nov Dec Dec Ventin Jan Feb Mar [X] A r May Jun Jul Aug Se [X) Oct [Xj Nov Dec. t ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 . 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 . 68 68 68 68 68 66. 66 MASS Mass Type Area Thickness FurnitureFraction Space Default(8lbs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8lbs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8lbs/sq.ft. ft2 ft 0.3 M. BATH Default(8lbs/sq.ft. ft2 ft 0.3 LAUDRY Default(8lbs/sq:ft. ft2 ft 0.3 BEDROOM 2 Default(8lbs/sq.ft. ft2 ft 0.3 DINING/GREAT PO Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN 4/21 /2020 10:04 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY: CHECKLIST REPORT MASS . Mass Type Area Thickness Furniture Fraction Space Default(8lbs/sq.ft. ftz ft 0.3 BATH Default(8lbs/sq.ft. ftz ft 0.3 HALL Default(8lbs/sq.ft. ftz ft 0.3 FOYER Default 8lbs/s .ft. ftz ft 0.3 BEDROOM.3 4/21/202010:04 AM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WIND SOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. -PIERCE, FL, Permit Number: Owner: Jurisdiction: l u Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION. CRITERIA . General A. continuous air barrier shall be installed in the.building-envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. . Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit y PP g /soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. . Exterior thermal envelope: insulation for framed . walls.shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall. be installed at any exposed edge of Floor framing cavity insulation shall be.installed to (including insulation. mairitain 'permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations . Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned s ace_ shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Pytpnri behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on.exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in.a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be.used to fill voids between fire spronkler.cover nlates and walls or railings, a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400. 4/21/2020 10:05 AM EnergyGauge® USA 6.0.02 (Rev. 1) = FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 201-7 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL.(EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.058 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285 14. Heating system: Capacity 34.8 c) Area 7c. 151.4 a) Split system heat pump. HSPF .8.5 b) Single.package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab-on=grade (R-value) 9a. 0.0 b) Wood,.raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank` EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry.(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R=value) 1062. 16. HVAC credits claimed (Performance. Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code; Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy .Conservation, through the above energy saving.features which will be installed (or exceeded): in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date:�U v Add ress<of New Home: VAS City/FL Zip: FT. PIERCE. FL 4/21/202010:05:25 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1