Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutProduct Approval; Swinging Exterior Door Assembliesi » Mt
�. t0 10 QPA a0F'n r . #� - r wn f tar
fed ar%A � %
P I�
BEAJnes�&�?��fssi�o�aaI�R�gulait�io�
d lorida
� OLI r
��c usar�s
4i�-c+r� "a+Rtuf
r1� Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL20468-R3
Revision
2017
Approved
0;
F' P '�
"VIEWEDVF9-
Ile Co - j
RR
CODE COMPLIANCE
ST. L CIE COU
ROCCt
Therma Tru Corporation
118 Industrial Drive
Edgerton, OH 43517
(419) 298-1740
rickw@rwbldgconsultants.com
Vivian Wright
rickw@rwbldgconsultants.com
Exterior Doors
Swinging Exterior Door Assemblies
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E.
Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2021
Validated By Ryan J. King, P.E.
S Validation Checklist - Hardcopy Received
Certificate of Independence
FL20468 R3 COI (c) Certificate of Independence.pdf
Referenced Standard and Year (of Standard)
Standard
Year
AAMA/WDMA/CSA101/I.S.2/A440
2005
ASTM E1886
2005
ASTM E1886
2002
ASTM E1996
2009
ASTM E1996
2006
ASTM E1996
2002
ASTM E1996
2005
ASTM E330
2002
TAS 202
1994
Equivalence of Product Standards
Certified By
Florida Licensed Professional Engineer or Architect
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJvPDe9aJxCeipMlx3L49J!2bmWnAMJJdAw%3d%3d 1/4
10/4/202p
r i
Florida Building Code Online
FL20468 R3 Equiv EQUIVALENCY OF STANDARDS.pdf
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Summary of Products
Method 1 Option D
10/09/2018
10/11/2018
10/21/2018
12/11/2018
07/12/2020
FL #
Model, Number or Name
Description
20468.1
a. Thermo Tru Fiber -Classic and
Nominal 6'8 "Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door (Inswing/Outswing; X configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20468 R3 II (e) Inst 20468.1.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20468.1 for Design Pressure Ratings, any
FL20468 R3 AE _(c)_Eval 20468.1.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star Door panels,
this product approval requires the use of "J" part numbers for
these doors, which have been stained or painted within six
months of installation.)
20468.2
b. Thermo Tru Fiber -Classic and
Nominal 6'8 "Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door with Sidelite(s) (Inswing/Outswing; XO, OX or OXO
configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20468 R3 II (e) Inst 20468.2.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20468.2 for Design Pressure Ratings, any
FL20468 R3 AE (d) Eval 20468.2.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star Door and
Sidelite panels, this product approval requires the use of "]"
part numbers for these doors, which have been stained or
painted within six months of installation.)
20468.3
c. Thermo Tru Fiber -Classic and
Nominal 6'8 "Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Double Door with or without Sidelites (Inswing/Outswing; XX
or OXXO configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20468 R3 II (e) Inst 20468.3.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20468.3 for Design Pressure Ratings, any
FL20468 R3 AE (d) Eval 20468.3.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star Door and
Sidelite panels, this product approval requires the use of "Y'
part numbers for these doors, which have been stained or
painted within six months of installation.)
20468.4
d. Thermo Tru Fiber -Classic and
Nominal 8'0 "Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door (Inswing/Outswing; X configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20468 R3 II (g) Inst 20468.4.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20468.4 for Design Pressure Ratings, any
FL20468 R3 AE (c) Eval 20468.4.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star Door panels,
this product approval requires the use of "T' part numbers for
these doors, which have been stained or painted within six
months of installation.)
https://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgsJ9a49YAgXJvPDe9aJxCeipMlx3L49Ji2bmWnAMJJdAw%3d%3d 2/4
Florida Building Code Online
10/4/2020
t
20468.5
e. Therma Tru Fiber -Classic and
Nominal 8'0 "Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door with Sidelite(s) (Inswing/Outswing; XO, OX or OXO
configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20468 R3 II (g)_Inst 20468.5.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20468.5 for Design Pressure Ratings, any
FL20468 R3 AE (d) Eval 20468.5.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star Door and
Sidelite panels, this product approval requires the use of "Y
part numbers for these doors, which have been stained or
painted within six months of installation.)
20468.6
f. Therma Tru Fiber -Classic and
Nominal 8'0 "Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Double Door with or without Sidelites (Inswing/Outswing; XX
or OXXO configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20468 R3 II _(e)_Inst 20468.6.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20468.6 for Design Pressure Ratings, any
FL20468 R3 AE (d) Eval 20468.6.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star Door and
Sidelite panels, this product approval requires the use of "Y
part numbers for these doors, which have been stained or
painted within six months of installation.)
20468.7
g. Therma-Tru Fiber -Classic and
Nominal 6'8 "Impact" Glazed Composite Edge Fiberglass Single
Smooth -Star
Door (Inswing/Outswing; X configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20468 R3 II (g) Inst 20468.7.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20468.7 for Design Pressure Ratings, any
FL20468 R3 AE (d) Eval 20468.7.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star Door panels,
this product approval requires the use of "Y part numbers for
these doors, which have been stained or painted within six
months of installation.)
20468.8
h. Therma Tru Fiber -Classic and
Nominal 6'8 "Impact" Glazed Composite Edge Fiberglass Single
Smooth -Star
Door with Sidelite(s) (Inswing/Outswing; XO, OX or OXO
configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20468 R3 II (e) Inst 20468.8.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20468.8 for Design Pressure Ratings, any
FL20468 R3 AE (d) Eval 20468.8.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star Door and
Sidelite panels, this product approval requires the use of "Y
part numbers for these doors, which have been stained or
painted within six months of installation.)
20468.9
i. Therma Tru Fiber -Classic and
Smooth -Star
Nominal 6'8 "Impact" Glazed Composite Edge Fiberglass
Double Door with or without Sidelites (Inswing/Outswing; XX
or OXXO configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20468 R3 II (e) Inst 20468.9.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20468.9 for Design Pressure Ratings, any
FL20468 R3 AE (d) Eval 20468.9.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star Door and
Sidelite panels, this product approval requires the use of "T'
part numbers for these doors, which have been stained or
painted within six months of installation.)
20468.10 j. Therma-Tru Fiber -Classic and Nominal 8'0 "Impact" Glazed Composite Edge Fiberglass Single
Smooth -Star Door (Inswing/Outswing; X configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20468 R3 II (e) Inst 20468.10.pdf
https://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgsJ9a49YAgXJvPDe9aJxCeipMlx3L49Ji2bmWnAMJJdAw%3d%3d 3/4
Florida Building Code Online
10/4/2020
V_ , .
Approved for use outside HVHZ:. Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20468.10 for Design Pressure Ratings, any
FL20468 R3 AE (d) Eval 2 4468.10 p-df
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star Door panels,
this product approval requires the use of "Y' part numbers for
these doors, which have been stained or painted within six
months of installation.)
20468.11
k. Thermo Tru Fiber -Classic and
Nominal 8'0 "Impact" Glazed Composite Edge Fiberglass Single
Smooth -Star
Door with Sidelite(s) (Inswing/Outswing; XO, OX or OXO
configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20468 R3 II (e) Inst 20468.11.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20468.11 for Design Pressure Ratings, any
FL20468 R3 AE (dJ Eval 20468.11.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star Door and
Sidelite panels, this product approval requires the use of "Y
part numbers for these doors, which have been stained or
painted within six months of installation.)
20468.12
I. Thermo Tru Fiber -Classic and
Nominal 8'0 "Impact" Glazed Composite Edge Fiberglass
Smooth -Star
Double Door with or without Sidelites (Inswing/Outswing; XX
or OXXO configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20468 R3 II (g) Inst 20468.12.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20468.12 for Design Pressure Ratings, any
FL20468 R3 AE (d) Eval 20468.12.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star Door and
Sidelite panels, this product approval requires the use of "]"
part numbers for these doors, which have been stained or
painted within six months of installation.)
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
MM
Credit Card
Safe
htips://www.floridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJvPDe9aJxCeipMlx3L49Ji2bmWnAMJJdAw%3d%3d 4/4
THERMAITRU"
DOORS
Fiber -Classic. & Smooth -Stara
COMPOSITE EDGE
GLAZED FIBERGLASS SINGLE DOOR
INSWING/OUTSWING
"IMPACT'
GENERAL NOTES
1. This product has been evaluated and is in compliance with the 6th Edition
(2017) Floddo
Hurricane Building
Code
(FBC) structural requirements excluding the "High
2. Product anchors shall be as fisted and spaced as shown on details. Anchor
embedment to base material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind bome debris protection this product
complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an
Impact resistant covering. This product meets missile level "D" and Includes Wind
Zone 4 as defined In ASTM El996 and FBC Sections 1609.1.2.2 & R3012.1.2.1.
4. For 2x stud framing construction, anchoring of these units shall be the some as
that shown for 2x buck masonry construction.
5. Site conditions that deviate from the details of this drawing require further
engineering analysis by a licensed engineer or registered architect.
6. Fiber -Classic & Smooth -Star Door panels require the use of "S' part numbers and
must be stained or painted within six months of installation.
TABLE OF CONTENTS
37.75' MAX O.A.
FRAME WIDTH
>z_ z
Q y
0? °o
� � W
m�
L=j
//
�SS
1 11co17
Mmz
o
m U N
O
e 9 Z x Z
Em m V m
c
a uxa 9 cw
amx 5dLa
maa�
E oZ
8 3a
DESIGN PRESSURE (PSF)
DESIGN PRESSURE (PSI)
LOCK
INSWING
OUTSWING
CONFIGURATION
HARDWARE
POSITIVE
NEGATIVE
POSITIVE
NEGATIVE
X
Latch & Deadbolt
+47.0
-53.0
+50.0
-50.0
X
Multipolnt
+50.0
-50.0
+50.0
-50.0
See Sheet 3 for Hardware Specifications
sCA E N.T.S.
WG. W. JK
ir- aO LFS
FL-20468.7
fir t OF 12
EXTERIOR 1.875'--1
0.5" 1.199 Gl
COMPOSITE
CAP
INTERIOR LOCKBL BLOCK STILE
COMPOSITE HINGE STILE (I 2S5' LONG LVQ (ENGINEERED WOOD)
CAP (ENGINEERED WOOD) rl-'\ HORIZONTAL CROSS SECTION
1.876"
0A6, 1.198, EXTERIOR
GI SMIOR 1.199, 0.406'
COMPOSITE
CAP
L
*INTERIOR LOCK BLOCK STILE
COMPOSITE HINGE STILE (12FLONG WOOD) (ENGINEERED WOOD)
CAP (ENGINEERED WOOD) /-2"-\ HORIZONTAL CROSS SECTION
36.0'MAX. DOOR 35.813'MAX. DOOR 35.813'MAX. DOOR
PANEL WIDTH PANEL WIDTH PANEL WIDTH
w— I
INTERIOR
TOP RAIL
(COMPOSMENGINEERED
/ WOOD)
- FOAM CORE
(POLYURETHANI
1.9 PCF MIN.)
EXTERIOR INItKiux
Z, A
0;
0 Y.)
cn
co
ZO On 01 ZO
0 C4 -t
Ea 0
mo .0 IL
6u cW
m a: 1L
o 'mod
ERIOR
FIBERGLASS sriN
0
(0.073'THK.)
BOTTOM RAIL
1.71" (COMP.) 1.71"
j3 VERTICAL CROSS SECTION VERTICAL CROSS SECTION
2
)��
g�900�R PANEL
Hy
brid
.r
41 Hybrid Door
JK
er LFS
FL-20� 468JYWO 1.7
I
vEr 2 OF 12
nl
91
SEE HARDWARE
CHART
SCHLAGE
KNOB: FST
DEADBOLT B60
KNOB: SIGNATURE SERIES
KWIKSET
DEADBOLT SIGNATURE SERIES (960]
HOPPE
MULTIPOINT:MPDGART
(THERMA•TRU)
(3 pT. Manual Tongue)
ii-
111
ICI wI-
� i� Illllll� �
Fiber-Classic/Smooth-Star Door Panel Options
Products approved include all embossed and recessed panel doors.
Similar glazed panel configurations are allowed.
Panels shown are for illustration and are representative only.
IV
W
a.
o o 'm
b% UN••
oov
taxi
8=g
9m�
o
9 `aa'. a
WAL N.T.S.
Bwc. By. JK
alr. ar: LFS
FL-20468.7
Er 3 OF 12
Z d
-23
EXTERIOR JZ� INTERIOR
1 VERTICAL CROSS SECTION
4 � g/shown (Inswing drr lar)
1.15' MIN.
EMB. (TYP.)
0.15' C•SINK O.1S' C•SINK
♦ . (TYP))
e,
e
♦ 1 4
e" C jR10R
e 6
INTERIOR
INTERIOR ♦ pe• .
•de e
' n .
d' AJ
O
EXT:e '
23 EXTERIOR 27
40 41 42L 29 1
1-1/4' MIN.
EMB. (TYP.)
2 HORIZONTAL CROSS SECTION M1hu.,t�sw-h-glThown
ORIZOTAL CROSS SECTION
S sown O 2X Buck uck
S ownng shown (Inswing sim lar) (Inswing similar)
utswi
a
Ln
o
� !DS
Z aapm
$ao
Zo
m' w U N
V
axz�
E. 9mma
1. Na =Ota
8 4 mda�
n
E eZ
Z ciJ
a° 'mod
Y
Um
0
fair
•�z
J
¢�
N Ny
7I
O =0
�
� U
^'•n.•Q
i
O
J
M �`l
•' Z
_
v
DACE 08102116
1-1l4"MIN.
sauF N.T.S. o
EMU. (TYP.)
M. a!; JK m
(INK. W. LFS 3
DRAWING NO.: tt
m
FL-20468.7 0
tq
stir 4 of 12 ^
,tttlllllll///►
•Z�.,N2
a)O .il MJ
'
Z
p G •>
\ W
om
A. -i M
'flil
III
o °D
1 X Buck 10 be secured to
C
��
o a.. z°
masonry by others
$o
z l
E z
m
a t
as N 56LmM1m
LL
B 4
40 41 42
; 9 Z
7 1a
EXTERIOR INTERIOR
0
�m
1 VERTICAL CROSS SECTION
fxo
Byrn
$ Shownw/IXsub-bucker
Out=ng shown (Inswing smtifar)
o
A
E
o�
C
0
0
a
a
bv.
P,
v,
zoo
••
. . ......... .
7
oQo-.
N
°• 6
v
Cl
2
2
G INTERIOR
INTERIOR .:
G
Ed S
z
p
U O
K
vv •..
• EXTERIOR
' av
..
EXTERIOR
min
o•.^a
W
23 24
40 41 42
40 41 42 27 A
0
1-1/4"MIN. 29
1
1-1/4'MIN.
EMB
wh:08/02116
EMB. PP.)
.PP.)
sCM& N.T.S.
MG. Br: JK
2 HORIZONTAL CROSS SECTION
3 HORIZONTAL CROSS SECTION
CML BY. US
§ Shownw/1Xsubbuck
5 shown w/1XSub-buck
onWMNO-
Out=ng shown pnswtng 11-9-0
OutsMng shown Qnswing stmOor)
FL-20468.7
•
sxox 5 of 12
MAX.
EXTERIOR W MRIOR
%71 VERTICAL CROSS SECTON
6 Outsng only w 49/16�' jamb
4' C
iv INFERIOR
EMB. (TYP.J
5
WNW
MIN.
EMB. (TYP.)
2 HORIZONTAL CROSS SECTION 3 HORIZONTAL CROSS SECTION
6 Shown Direct to Masonry 6 Shown Direct to Masonry
Outswing only w/ 4-9/16' jamb Outswing only,/ 4-9/16' jamb
EXTERIOR FNTERJOR
4 VERTICAL CROSS SECTION
6 Outs ngonlyw/6-9/161'jomb
0 0
I
ICI!
0
4
JShown Direct to Masonry
Outswing onlyw/ 6-9116'jamb
INTERIOR
EXTERIOR
I
MAX.
C�
Fo z
.e a
N
a
�� W^ gn
��-1 §;.gym
Z MDMo
U N •;Z
e Z O = U
E cmop Bm u
I (nq 7 0 L a
LLYY m dad
o
E a2
Sa
0
o
:�o o
8
U
�_
MIN.
=
EMB.
MB. jTYP.J
WE 08 02 16
d
sr c• N.T.S.
6 HORIZONTAL CROSS SECTION
om BY: JK m
6 Shown Direct to Masonry
croc er LFS
Outswingonly w/6-9/16'jamb
DRAWWG NO,,
FL-20466.7 c
Isum 6 of 12 g
A
Notes:
l -SIR Item #'s 17,18, 32, 34, 35, 36, 37, 38 $ 39 are attached to Jambs w/ (3) 48 X 2-1 /2" pfh screws at each end.
S11 Item #'s 16 & 33 are attached to jambs w/ (2) 98 X 2-1/7' pfh screws at each end.
Sill Item 415 is attached to Jambs utilizing (2) # 10 X 7' pph screws at each end.
INTERIOR
EXTERIOR
1 VERTICAL CROSS SECTION
7 Inswing S71
EXTERIOR F7Zj INTERIOR
SEE NOTE I
© VERTICAL CROSS•
v.
EXTERIOR
SEE NOTE 1
INTERIOR
SEE NOTE 1
EXTERIOR
VERTICAL CROSS SECTION
7 Inswing Sill
INTERIOR
b
VERTICAL CROSS SECTION
J Public Access S11
z`40 y
i N::� z
$ "W ' ,
y A
M
y� oa
5, m>M�
°D ii 0 P) z0
m" U N ••
O
C° E C Z m Z U
a m 9atn
9 LL M IL
d
E c
y
9
Zo
Ck:9
�I r
kM N.T.S.
G. Br: JK m'
K BY. LFS 3
kWM NO.: rc
m
FL-2046B.7 0
MT —L OF 12 H
Q
co
O" Z
PFH WS o U N •:
JAMB TO HEAD DETAIL o E 8 i o z �
4"frP•1—►{II ^ Z. 4g 9 m oa
N mar
Ba mdaT
I a E Cooz
JTa
p L 2X BUCK z
HEAD B,JAMBS J IX BUCK �o is
BUCK ,o �� Q
M DIRECTTON J
2X BUCK N MASONRY wM m
FRAME HEAD & JAMBS m d!
O
O m
O
a
a
m
U
ILI
^O z
zon
o l z
MASONRY c
�iW4 ti
2X BUCK ANCHORING FRAME ANCHORING lz�1
-
o
m
M N ^ Z G
DArz 08102116 i
SCALE N.T.S. 9
oxro. at: JK m'
C'm ar: LFS
DRAWMD N0-
FL-20468.7
0
st= 8 OF j 2 N
2X BUCK L 28
IXBUCK G
DIRECTTO M 26
MASONRY
2X BUCK 25
1XBUCK G 27
DIRECT TO M
MASONRY
LATCH & DEADSOLT DETAIL
Kwilaet
2X BUCK
1X BUCK
DIRECT TO
MASONRY
Strike Plate
SEE LATCH
& DEADBOLT
DETAIL
G?
Eo
qI�/ �� / 22 STRIKEJAMB
2X BUCK 25 Latch and Deadbolt
IXBUCK G 27
DIRECT TO M
MASONRY
LATCH & DEADBOLT DETAIL
Schlage BB
LATCH & DEADBOLT STRIKE DETAILS M DIRECT TO
MASONRY
DEADBOLT STRIKE DETAILS
(Security Deadbolt Strike Plate)
o
o_ d
O
m gm
PLO NO
SEE HINGE
DETAIL (TYP.)
0'
_ O
O i0
oo �o
ry00 �xmx
m N G
HINGE JAMB
HINGE DETAIL
SEETONGUE
STRIKEDETAIL
(TYP•)
SEE LATCH
& DEADBOLT
DETAIL
di
ri'•'- a
��
% Ft
11 P
y m
m
zocoo
\\
Cg�Y
o
UN ..=
p E Z oza
C$tc
V
mo
oa 9 cw
E o a.
a w d
a
A co
+� 2X BUCK L
1XBUCK G
E az
f c41
o �d
l
DIRECTTO M p
Q
MASONRY 31
�o
0
I y
O
TONGUE STRIKE DETAIL
m
u ipo n oc
a
3
L
0
GI
a
O
a
2X BUCK
W 1XBUCK
STRIKEJAMS DIRECTTO
Multipoint Lock MASONRY
LATCH & DEADBOLTDETAIL
2X BUCK u po c
X BUCK
DIRECTTO
WtSONRY
M ULTIPOINT LOCK STRIKE DETAILS
uE N.T.S.
c. w: JK m
C. BY: LFS 3
WNG NO.:
FL-20468.7 0
ET 9 OF 12
C
EXTERIOR
CELLULAR 1/2' GLASS BITEGLAZING TAPE
1"THK. GLASS
VIT'TEMPERED GLASS
;:;;• : 1/T AIR SPACE
5/37' ANNEALED GLASS
DOW 995 0.090" PVB INTERLAYER
OR (SAFLEX OR KURARAY BUTACITE)
SIKA 552
1 /6" ANNEALED GLASS
#10X1-1/2"PPHSMS 3A
INTERIOR SWIGGLEGLAZINGSPACER
Gll GLAZING DETAIL
Atumtnum Impact life Frame
Door Panels & Side6tes
1.53"
-L
3A ALUMINUM FRAME
Aluminum Impact lite Frame
Door Panels & Side6tes
20.ff D.L.O.
WIDTH
~s
U
O
CV
C9
w
^
x
O
J
h
#
--�
1
-
(TyP)
fCh
y' �
ALUMINUM UTE FRAME
X 1-1/2' PPH SMS
(TYP.)
tot . d
Q \1
INTERNAL GRID (GBG) WROUGHT IRON INSERT V
PRIVACY INSERT
1" LAMINATED INSULATED IMPACT GLASS INSERT OPTIONS
ISERT
'e'w; m
-.-z Co
� om
(� U N oZ
0 o v
Z 4.4
Em m
e4 mdaa..�
d
E oZ
No7
F
c
MN�^Z 0
M 08102116 =
+LF- N.T.S. °
V. By. JK m
K Be LFS 3
aMNG NO.:
FL-20466.7 0
rr 10 of 12 N
__
a
7.59"
INSWING THRESHOLD
32 Iruwing Bozic Composite Adjustable 5517-1/T
4.56"
33 INSWING 7HRESHOID
W, g Basic FDced Sm
5.75'
INSWING THRESHOLD
Iruwing Moderate Cgmate Sig 1-3ff
5.75"
h
35 INSWING THRESHOLD
Inswing Moderate Cgmate Sig
5.7.
36 LNSWING THRESHOLD
inswing Basic FDced 5.3/4" Sm
ry 4.56" In
3`fYvrs7v_A.`r.l'�.r.'i-''•f4"r�4"�rf�.,n:1:4^<< '���� OY�_��`` J � m f
{ I '1 1111 jo y M
=om,
37 INSING iHRESHOID WOOD JAMB \ $ ° o 0
Insw ng Basic Faed 7-1Ir Sm jO V o E o, 9 m m l
aNg 9oL�
o[
4.56" 5.83" e a f
o
'c L4
o° °1a.
cc
38 INS WINGTHRESHOLD 16 OUTSWtRGTHRESHOID o w
Insv ng Composite Adjustable Sill Compos to Sol z
m d
zn 5.77" 4.56 �m c'
o �
o.
INSWING THRESHOLD
39 tnsw ng .:I
c Composite Adjustable Sill 17 OUiSWING THRESHOLD �-"
Composite / Aluminum SIII z
zoo
�Fo
ON �
O Z
C
6.1)" ru
0 5.75' .cam c
L
0 0 0�0
m oR
¢ a
OULSWING THRESHOLD ro r"
uj
15 PUBNCACCESSTHRESHOLD 1B jm tp-ll eakuminumSll o ^
j o ^o
M N ^ Z
I � unAz N.T.S..S16
L DW N.
mvc. ar: JK
»-1.74' -►{ 1.97' {-- 206" ----� T cm at: LFS
O. m DRwm No.:
d B SWEEP 9 SWEEP 10 SWEEP o FL-20468.7
1,1111tlllJJJr�
BILL OF MATERIALS
BILL
60
� N
I
? z°
v%
zel0 e
�•.,,
d
ru �F)
ttGo
z dm d
\\v`a
S
o
(y x Z
E E W z m a U
tN 9doa
d
z
p�
S a
go
iEm
o
J
J
��
O m
0
a
0
z
m
zon
CONCRETEANCHORNOTES:
1. Concrete anchor locations at the be to
01
fir',
En
z
comers
may adjusted
maintain the min.
9
edge distance to mortorjoints.
a
�g
- LA
2. Concrete anchor locations noted as MAX. ON CENTER" must be adjusted to
the distance to
z
a o
Pu''
maintain min. edge morforjoints, additional concrete anchors
may be required to ensure the MAX. ON CENTER" dimension are not exceeded.
o
O
`�
3. Concrete anchor table:'
z
c
z
w z
Q J
m
Z
Z V
M
N —
DAM 08 02116 =
sr m- N.T.S. o
5
owc.Irr: JK m
WOOD SCREW INSTALLATION NOTES:
CHYL Eft LFS ?
NO-
1.Maintain aminimum 5/8" edge distance, 1' end dafance, & 1"o.c. spacing of
txsAwwa
wood screws to prevent the splitting of wood.
m
FL-20468.7 0
SHEET t2 OF J2
Of MATERIALS
iTE161$
DESCRIPTION
MATERIAL
ITEM B
DESCRIPTION
MATERIAL
A
1 X BUCK (SG >= 0.42J
WOOD
25
#8 x 2-1 /2"PFH WOOD SCREW
STEEL
B
2X BUCK (SG >= 0.42)
WOOD
26
#8 x 5/8" PFH WOOD SCREW
STEEL
C
1/4"MAX. SHIM SPACE
-
27
LATCH STRIKE PLATE
STEEL
D
1 /4" X 2-3/4"PFH ELCO OR ITVJ CONCRETE SCREW
STEEL
28
DEADBOLT STRIKE PLATE (STANDARD)
STEEL
E
MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90
CONCRETE
28A
DEADBOLT SUB STRIKE PLATE
STEEL
286
DEADBOLT STRIKE PLATE (SECURITY)
STEEL
G
3/16" X 3-1 /4" ITW CONCRETE SCREW
STEEL
29
4" X 4"HINGE
STEEL
J
1 /4" X 3-3/4"PFH ELCO OR RW CONCRETE SCREW
STEEL
30
LATCH & DEADBOLT STRIKE PLATE (TONGUE SYSTEM)
ALUM/COMP
L
#10 X 2-1/7' PFH WOOD SCREW (1.15"MIN. EMBEDMENT)
STEEL
31
MULTIPOINT STRIKE PLATE (TONGUE SYSTEM)
ALUM/COMP
M
3/16" X 2-1 /4" ITW CONCRETE SCREW
STEEL
32
INSWING THRESHOLD
ALUM/COMP
N
3/16" X 2-3/4" ITW CONCRETE SCREW
STEEL
33
INSWING THRESHOLD
ALUM/COMP
1
JAMB (FINGER JOINT PINE)
WOOD
34
INSWING THRESHOLD
ALUM/COMP
6
WEATHERSTRIP (MEDIUM REACH)
FOAM
35
INSWING THRESHOLD
ALUM/COMP
7
WEATHERSTRIP (LONG REACH)
FOAM
36
INSWING THRESHOLD
ALUM/COMP
8
SWEEP
VINYL
37
INSWING THRESHOLD
ALUM/COMP
9
SWEEP (USE w/ MODERATE CLIMATE THRESHOLD)
VINYL
38
INSWING THRESHOLD
ALUM/COMP
10
SWEEP (USE w/ PUBLIC ACCESS THRESHOLD)
VINYL
39
INSWING THRESHOLD
ALUM/COMP
15
PUBLIC ACCESS THRESHOLD
ALUM
40
DOOR PANEL (BOOK)
_
16
OUTSWING THRESHOLD
ALUM/COMP
41
DOOR PANEL (HYBRID)
_
17
OUTSWING THRESHOLD
ALUM/COMP
42
DOOR PANEL (Ul)
-
18
OUTSWING THRESHOLD
ALUM/COMP
22
#8 x 3/4"PFH WOOD SCREW
STEEL
23
# 10 x 3/4' PFH WOOD SCREW
STEEL
24
#10 x i"PFH WOOD SCREW
STEEL
sAivcFloR
AN�FIcSk
MrN
MIN cLEgRANeE
MIN. clEARaNc�
TYPE
TO MASONRY
7'OADJACEM'
...........
�� �
.••,••
:FJ�iBEptii�NT
.............:�:.:::.-.EDGE.:.:_::•r,:::.::.:;::::.ANGHOR�.:...-:
irw ®
TAPCON
tla^
t-t/a^
z^
a^
ELCO
ULTRACON®
1/4"
4"
INY ®
TAPCON
3/16"
1-1/a"
AS SHOWN
1-1/2"