Loading...
HomeMy WebLinkAboutMITSUBISHI INFO, SUBMITALSM-SERIES Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. Job Name: System Reference:Date: SUBMITTAL DATA: MSZ-HM18NA-U1 & MUZ-HM18NA2-U1 18,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Indoor Unit: MSZ-HM18NA-U1 Outdoor Unit: MUZ-HM18NA2-U1Wireless Remote Controller ACCESSORIES: Indoor Unit □Condensate Pump (BlueDiamond X87-711/721; 115/230V) □Condensate Pump (Sauermann SI30-115/230; 115/230V) □Anti-Allergy Enzyme Filter (MAC-408FT-E) □Drain Pan Level Sensor (DPLS2) Outdoor Unit □Outdoor Mounting Pad (ULTRILITE1) □Drain Pan Heater (MAC-640BH-U) □3-1/4” Mounting Base [Pair] (DSD-400P) □Drain Pan Socket (MAC-860DS) □Air Outlet Guide (MAC-889SG) □Wall Mounting Bracket (QSWB2000M-1) SPECIFICATIONS: Rated Conditions (Capacity / Input) Cooling1 Btu/h / W 17,200 / 1,640 Heating at 47º F2 Btu/h / W 18,000 / 1,590 Capacity Range Minimum Maximum Cooling1 Btu/h 5,800 18,000 Heating at 47º F2 Btu/h 5,400 20,900 Heating at 17º F3 Btu/h -15,000 Heating at 5º F4 Btu/h -12,700 1 Cooling | Indoor: 80º F(27º C)DB / 67º F(19º C)WB; Outdoor: 95º F(35º C)DB / 75º F(24º C)WB* 2 Heating at 47ºF | Indoor: 70º F (21º C)DB / 60º F (16º C)WB; Outdoor: 47º F (8º C)DB / 43º F (6º C)WB* 3 Heating at 17º F | Indoor: 70º F(21º C)DB / 60º F(16º C)WB; Outdoor: 17º F(-8º C)DB / 15º F(-9º C)WB* 4 Heating at 5º F | Indoor: 70º F (21º C)DB / 60º F(16º C)WB; Outdoor: 5º F(-15º C) DB / 5º F(-15º C)WB * Rating Conditions per AHRI Standard: Operating Conditons (Indoor Intake Air Temp.) (Max./ Min.) Cooling 90º F (32º C) DB / 67º F (19º C) DB Heating 80º F (27º C) DB / 70º F (21º C) DB Operating Conditons (Outdoor Intake Air Temp.) (Max./ Min.) Cooling5 115 F (46º C) DB / 14º F (-10º C) DB Heating 75º F (24º C) DB / 5º F (-15º C) DB** 5 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. ** System cuts out at -9º F (-27º C) to avoid thermistor error and automatically restarts at -4º F (-20º C). AHRI Efficiency Ratings SEER / HSPF 18.0 / 8.5 COP at 47o F / 17o F 3.32 / 2.59 Electrical Power Requirements 208 / 230V, 1-Phase, 60 Hz Minimum Circuit Ampacity (MCA) Indoor / Outdoor A 1 / 10 Indoor Unit Blower Motor (ECM)F.L.A.0.67 Blower Motor Output W 30 SHF / Moisture Removal 0.86 / 2.1 pt./h Field Drainpipe Size O.D.In.(mm)5/8 (15) Outdoor Unit Compressor DC INVERTER-driven Twin Rotary Fan Motor (ECM)F.L.A.0.5 Airflow Rate (Lo - Med - Hi - Super Hi) Indoor (Cooling) DRY CFM 328-431-530-625 WET 295-388-477-562 Indoor (Heating)DRY 307-431-530-625 Outdoor 1,243 / 1,229 Sound Pressure Level (Lo - Med - Hi - Super Hi) Indoor Cooling dB(A) 30-37-42-47 Heating 30-37-42-47 Outdoor Cooling 49 Heating 51 External Dimensions Indoor (H x W x D) In.(mm) 12 x 36-5/16 x 9-13/16 (305 x 923 x 250) Outdoor (H x W x D)21-5/8 x 31-1/2 x 11-1/4 (550 x 500 x 285) Net Weight Indoor Lbs.(kg)28 (13) Outdoor 81 (37) External Finish Indoor Munsell 1.0Y 9.2 / 0.2 Outdoor Munsell No. 3Y 7.8 / 1.1 Refrigerant R410A; 2 lb. 10 oz. Refrigerant Piping (Flared) Liquid (High Pressure)In.(mm)1/4 (6.35) Gas (Low Pressure)1/2 (12.7) Max. Total Refrigerant Pipe Length (Height Diff.) Ft. (m) 40 (12) Max. Total Refrigerant Pipe Length (Length.)65 (20) Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com FORM# MSZ-HM18NA-U1 ~ MUZ-HM18NA2-U1 - 201603 DIMENSIONS: MSZ-HM18NA-U1 & MUZ-HM18NA2-U1 MSZ-HM18NA-U1 Unit: in. (mm) MUZ-HM18NA2-U1 Unit: in. (mm) 7 Unit: inchMSZ-HM09NA MSZ-HM12NA MSZ-HM15NA MSZ-HM18NA MSZ-HM24NA 4 OUTLINES AND DIMENSIONS PipingInsulation MSZ-HM24NA Ø2 O.D Liquid line Ø5/16 15-3/8 (Flared connection Ø3/8) Gas line Ø15/32 13-3/8 (Flared connection Ø5/8) Drain hose Insulation Ø1-1/8 Connected part Ø5/8 O.DPipingInsulation MSZ-HM18NA Ø2 O.D Liquid line Ø5/16 15-3/8 (Flared connection Ø1/4) Gas line Ø15/32 13-3/8 (Flared connection Ø1/2) Drain hose Insulation Ø1-1/8 Connected part Ø5/8 O.D 11/16 5-1/22-1/42-1/42-1/2 9-13/16 3/16 35-13/16 36-5/16 1/4 27-15/16 6-5/162-1/1612 2-9/16 2-13/162-1/22-9/16 3-11/16 2-1/169-7/1610-5/161/88-7/8 8-7/83-11/16 8-3/410-3/82-5/16 15-7/8 8-11/16 3-11/16 7/81×7/16 Oblong hole 7/16×13/16Oblong holeInstallation plate Indoor unit Wall hole Ø3Air in Installation plate 8-1/16 15-3/161-5/88-11/163 1-11/162-9/16 2-9/164-1/2 5-3/41/4Air out Piping Drain hose3-15/1611/16 5-1/22-1/4 PipingInsulation ø1 - 3/8 O.D Liquid line ø1/4 19 - 11/16 (Flared connection ø1/4) Gas line ø3/8 16 - 15/16 (Flared connection: ø3/8 (HM09/12NA), ø1/2 (HM15NA)) Drain hose Insulation ø1-1/8 O.D Connected part ø5/8 O.D OBH746A 9 OUTLINES AND DIMENSIONS4 Unit: inchMUZ-HM09NA MUZ-HM09NA2 MUZ-HM12NA MUZ-HM12NA2 clear *1*1 4 in. (100 mm) or more when front and sides of the unit are clear *2 When any 2 sides of left, right and rear of the unit are clear holes REQUIRED SPACE Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø 1/4 Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 3/8 (HM09/12) Ø 1/2 (HM15/18) 4 in. (1 0 0 m m)or more 14 in . ( 3 5 0 m m ) or m o r e8 in. (200 m m) or more * 2 4 in. ( 1 0 0 m m ) or m o r e MUZ-HM15NA MUZ-HM15NA2 MUZ-HM18NA MUZ-HM18NA2 OBH747A