FORM R405-2017
ri
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRWTTJ
Florida Department of Business and Professional Regulation - Residential Performance MetftP�r
Project Name: Montoya Residence
Builder Name: Dansar Homes
Street: 2802 Grove Street
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce , FL, 34981
Permit Number:
Owner: Montoya Residence
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1746.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1447.50 ft2
b. Frame - Wood, Adjacent
R=11.0 298.67 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1614.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1614.00 ft2
6. Conditioned floor area above grade (ft2) 1514
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(125.8 sqft.) Description Area
a. Sup, -Attic, Ret: Attic, AH: Garage
6 105
a. U-Factor: Sgl, U=0.65 125.80 ft2
�' LE ®��
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
30.0 SEER:15.75
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. ElectricSREeVIEWED
FOR27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
QODE COMPLIANCE
Area Weighted Average SHGC: 0.250
14. Hot water s stems
a. Electaf. LUCIE COUNT* 50gallons
8. Floor Types (1614.0 sqft.) Insulation Area
EF:0.950
a. Slab -On -Grade Edge Insulation R=0.0 1614.00 ft2
b. Conservation featurBOCC
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.078 Total Proposed Modified Loads: 55.83
PASS
Total Baseline Loads: 56.51
I hereby certify that the plans and specifications covered by
Review of the plans and
8T•4?�
this calculation are in compliance with the Florida Energy
specifications covered by this
O�T>IE
Code.
calculation indicates compliance
with the Florida Energy Code.
14.r��„��w •,;�:w ;,.�=„ O
PREPARED Y'
DATE: 9-2
Before construction is completed
this building will be inspected for
compliance with Section 553.908
O �.
I hereby certify that this bu' g, as designed, is in compliance
Florida Statutes.
1�; �•S
with the Florida Energy d
COD yiO
OWNER/AGENT: �s
BUILDING OFFICIAL:
DATE: zv
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH60 (R402.4.1.2).
1/28/2020 8:12 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Montoya Residence
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1614
Lot #
Owner Name: Montoya Residence
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
Plat Book:
Builder Name: Dansar Homes
Rotate Angle: 0
Street:
2802 Grove Street
Permit Office: St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: St. Lucie County
Whole House Fan: No
City, State,
Zip:
Fort Pierce ,
Family Type: Single-family
FL, 34981
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V/ Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1614 15475.6
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 Bedroom 3
245 2303 No 1
1
1
Yes
Yes
Yes
2 Bath 2
66 620.4 No 0
1
Yes
Yes
Yes
3 Bedroom 2
201 1889.4 No 1
1
1
Yes
Yes
Yes
4 Kitchen
224 2105.6 Yes 2
1
Yes
Yes
Yes
5 Dining
64 601.6 No 0
1
Yes
Yes
Yes
6 Master Bedroom
304 3161.6 No 2
1
1
Yes
Yes
Yes
7 Master Bath
84 789.6 No 0
1
Yes
Yes
Yes
8 Laundry
49 460.6 No 0
1
No
Yes
Yes
9 Great Room
340 3196 No 2
1
Yes
Yes
Yes
10 Hall
37 347.8 No 0
1
No
Yes
Yes
FLOORS
# Floor Type
Space . Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
Bedroom 3 33 ft
245 ft2
____
1 0
0
2 Slab -On -Grade Edge Insulatio
Bath 2 6 ft
66 ft2
___
1 0
0
3 Slab -On -Grade Edge Insulatio
Bedroom 2 34 ft
201 ft2
____
1 0
0
4 Slab -On -Grade Edge Insulatio
Kitchen loft
224 ft2
_-__
1 0
0
5 Slab -On -Grade Edge Insulatio
Dining 8 ft
64 ft2
___
1 0
0
6 Slab -On -Grade Edge Insulatio
Master Bedroom 35 ft
304 ft2
__
1 0
0
7 Slab -On -Grade Edge Insulatio
Master Bath 7 ft
84 ft2
__
1 0
0
1/28/2020 8:12 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio Laundry 1 ft
49 ft2
�-
1
0
0
9 Slab -On -Grade Edge Insulatio Great Room 17
ft
340 ft2
--
1
0
0
10SIab-On-Grade Edge Insulatio Hall 1 ft
37 ft2
1
0
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Composition shingles 1748 ft2
0 ft2
Medium
N
0.6
No 0.9
No 0
22.6
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1614 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) Bedroom 3
30
Batt
245 ft2
0.1
Wood
2
Under Attic (Vented) Bath 2
30
Batt
66 ft2
0.1
Wood
3
Under Attic (Vented) Bedroom 2
30
Batt
201 ft2
0.1
Wood
4
Under Attic (Vented) Kitchen
30
Batt
224 ft2
0.1
Wood
5
Under Attic (Vented) Dining
30
Batt
64 ft2
0.1
Wood
6
Under Attic (Vented) Master Bedroom 30
Batt
304 ft2
0.1
Wood
7
Under Attic (Vented) Master Bath
30
Batt
84 ft2
0.1
Wood
8
Under Attic (Vented) Laundry
30
Batt
49 ft2
0.1
Wood
9
Under Attic (Vented) Great Room
30
Batt
340 ft2
0.1
Wood
10
Under Attic (Vented) Hall
30
Batt
37 ft2
0.1
Wood
WALLS
Adjacent
Space
Cavity Width Height
Sheathing Framing Solar
Belo w
WAII TVPP
In
Arpa
1
N
Exterior Concrete Block - Int InsuBedroom 3
4.1 13
0 9
5
122.4 ft2
0
0
0.4
0
2
W
Exterior Concrete Block - Int InsuBedroom 3
4.1 20
0 9
5
188.3 ft2
0
0
0.4
0
3
W
Exterior Concrete Block - Int Insul Bath 2
4.1 6
0 9
5
56.5 ft2
0
0
0.4
0
4
E
Exterior Concrete Block - Int InsuBedroom 2
4.1 5
0 9
5
47.1 ft2
0
0
0.4
0
5
S
Exterior Concrete Block - Int InsuBedroom 2
4.1 14
0 9
5
131.8 ft2
0
0
0.4
0
6
W
Exterior Concrete Block - Int InsuBedroom 2
4.1 15
0 9
5
141.3 ft2
0
0
0.4
0
7
N
Exterior Concrete Block - Int Insul Kitchen
4.1 10
0 9
5
94.2 ft2
0
0
0.4
0
8
N
Exterior Concrete Block - Int Insul Dining
4.1 8
0 9
5
75.3 ft2
0
0
0.4
0
_ 9
N
Exterior Concrete Block - Int InsMaster Bedro
4.1 19
0 10
5
197.9 ft2
0
0
0.4
0
10
E
Exterior Concrete Block - Int InsMaster Bedro
4.1 16
0 10
5
166.7 ft2
0
0
0.4
0
11
E
Exterior Concrete Block - Int Insfflaster Bath
4.1 7
0 9
5
65.9 ft2
0
0
0.4
0
12
S
Exterior Concrete Block - Int InsL(Great Room
4.1 17
0 9
5
160.1 ft2
0
0
0.4
0
1 /28/2020 8:12 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INP11T Sl IMMARV r_141=f _KI I-QT RFanRT
WALLS
Adjacent
Space Cavity Width
Height
Sheathing Framing Solar Below
l.
13 N
14 N
_ 15 W
Garage Frame -Wood
Garage Frame - Wood
Garage Frame - Wood
Master Bath 11 12 9
Laundry 11 7 9
Great Room 11 13 9
4 112.0 ftz
4 65.3 ftz
4 121.3 ftz
0.23 0.4
0.23 0.4
0.23 0.4
0
0
0
DOORS
#
Ornt Door Type
Space Storms
U-Value Width Height
Ft In Ft In
Area
1
S Wood
Great Room None
.39 3
6 10
20.5 ftz
WINDOWS
Orientation shown is the entered, Proposed orientation.
#
Wall
Ornt ID Frame Panes
NFRC U-Factor SHGC Imp
Overhang
Area Depth Separation Int Shade
Screening
1
2
3
4
5
6
N 1 Metal Low-E Single
S 5 Metal Low-E Single
N 7 Metal Low-E Single
N 9 Metal Low-E Single
E 11 Metal Low-E Single
S 12 Metal Low-E Single
Yes 0.65 0.25 N
Yes 0.65 0.25 N
Yes 0.65 0.25 N
Yes 0.65 0.25 N
Yes 0.65 0.25 N
Yes 0.65 0.25 N
15.0 ftz 1 ft 0 in
20.0 ftz 1 ft 0 in
40.8 ftz 1 ft 0 in
15.0 ftz 1 ft 0 in
15.0 ftz 1 ft 0 in
20.0 ftz 1 ft 0 in
0 ft 5 in None
0 ft 5 in None
0 ft 5 in None
0 ft 5 in None
0 ft 5 in None
0 ft 5 in None
None
None
None
None
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
399 ftz 399 ftz 32 ft
9.4 ft
11
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000426
1805.5 99.12 186.41 .1589
7
HEATING SYSTEM
#
System Type
Subtype Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None COP:1
27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split SEER: 15.75 30 kBtu/hr 1000 cfm 0.7 1
sys#1
1/28/2020 8:12 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.95
50 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System
Model # Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
/ -- Supply —
-- Return—
Air
CFM 25
CFM25
HVAC #
�/ # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6 105 ft2
Attic
35 ft2
Default Leakage
Garage
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb
HeatinH Jan H Feb
Mar
Mar
Apr
Apr
May
May
[ ]Jun f Jul
rl Jun Jul
Au4
ri Au
X Se
l Sep
Oct
f � Oct H
Nov
Nov
Dec
f X� Dec
Ventin Jan Feb
X Mar
A r [
l
Ma
[ ] Jun [ Jul
Aug
[ Se
[X] Oct X
Nov
[ Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
78
78
78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
78 78
78
78
Heating (WD) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Bedroom 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Dining
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bedroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Laundry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Great Room
Default(8 Ibs/s .ft.
ft2
ft
0.3
Hall
1/28/2020 8:12 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
/y RFC�l��o
2017 EPL DISPLAY CARD 1001,
sI
ENERGY PERFORMANCE LEVEL (E L) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Garage
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
30.0
a) Split system SEER
15.8
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1614
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.650
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
14. Heating system: Capacity
27.0
c) Area
7c.
125.8
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
Yes
a) Under attic
11 a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be comp based on installed code compliant features.
Builder Signature: Date: -�;S/ !/ /Z.0 z 0
Address of New Home: 2802 Grove Street City/FL Zip: Fort Pierce, FL 34981
1/28/2020 8:12:31 PM EnergyGauge@ USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1