HomeMy WebLinkAboutBlower door testtl fal' ;u `�c'• u• ry. e; Planning a Development Services Building 2_1 Code Regulation Division 2300 Virginia Ave, Rm 291 Fort: Pierce, FI. 34980 2 Phone:772-462-2265 Fait:272-,Q62-6q.e_._3 BLOWER DOOR 1TE(.7� u V-0pM Mouse 110illtmdon Tesk PFeSCOR'dVe and PeHomance Miee clod Date. 10/ �1 J L a Contractor: j0.b Address: 13-� 6'� 0, Q.� r2 3 `F I > ( Cons`Cruaion, New Construe.-jon m Cornplef-a - s Eixisting m Ac.ter Addition E-rouse Infiitration T es•i Results SLC r-Iinna•L-e zone 2 CFm (501 _ ( 6 q r Volume = y l g 2 i cs'c mate: i I g Zo 10 ACE: (SO) = CFm (50) ]c 60 J Volume= iD, S Mec17017kc1 regrcirec' less than 3A10-1 PassilIg results mus' be & ACH (50) or less Pass ( ) Fail F-SC, llnerglf The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shali be conducted by either individuals as de fined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be penormed at any time after creation of all penetrations of the building thermal envelope. E-BC, residential Where the air Infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section IV11507.3. i estini; Conw@ nv Company Name: Pro -Duct ServiceS Address: '1915 Rio Vista Drive, Ft. Pierce, FL 3^949 I hereby certify that the above House infiltration results demonstrate compliance with FoC Energy Conservation requirements in accordance Sec�jon R402.4.1.2 Climate %one 2. X r- A Signature: Printed Name: Maitin 1•<lein License/Certification it: 506'1633 BUILDING PERFORMANCE INSTITUTE, INC. 107 Hermes Road, Suite 210 Malta, NY 12020 (877) 274-1274 www,bpi.org fj 0BPIMartin Klein BPI IDA: 5061633 5M' (SEE REVERSE SIDE FOR DESIGNATIONS AND EXPIRATION DATES) CERTIFIED PROFESSIONAL DESIGNATION EXPIRATION DATE Infiltration & Duct L: akap (IDL) 4, 260-021 BUILDING PERFORMANCE INSTITUTE, INC.