HomeMy WebLinkAboutone line -Sunderland, William 9.29.20 William Sunderland PV Module:(31)LG355N1C-V5
11.01KWDC 8.99KWAC Inverter:(31)Enphase IQ7PLUS-72-2-US
(240v)(290va)
(2) Branch circuits of 10 modules
(1) Branch circuit of 11 modules
Inverter output current: 1.21A
Max system output current: 37.51A
2-Solar Array #12/2 Romex in attic/ Outdoormounted
strings of 10 THWN in blklrcondedlg eMerior Photovoltaic Combiner Box
g Enphase Engage Cable lblklredlgr
modules #12/2 THWN-2 240V AC (Model#IQ-AMI-240-3)
lblklred Roof Mounted Junction Box Sch 80 PVC
240V (Soladeck model 0786-3115)
11 Enphase EnvoyQ 10A
20A monitori ng device CB
2 strings of 10 En phase IQ7+
CB
Microi nverters o 20A
(located under each panel)
CB
20A N
CB
1 1
#6 THWN green through
Solar Array out system #12/2 Romex in attic/
y THWN in conduit on exterior
string of 11 lblklredlgr
modules Enphase Engage Cable 240V AC
#12/2 THWN-2 Sch 80 PVC
lblklred
240V -———— ———-----
11 Enphase IQ7+
Microi nverters Bi-Directional #6 THWN
(located under each panel) utility Meter 240V AC
1-Phase Sch 80 PVC
240v
Service Side Tap
ii
1 1
1 1
CB 1 1
1 1
1 1
1 1
1 1 0
1 1 m
N 1 1
1 1
1 1
1 1
1
1 1
1 1 1 AC Disconnect 60A
1 1 Lockable and Fusible
1 1
Main Service Panel ADDRESS:4640 Christensen Rd.Fort Pierce,FL 34981
200 amp rated MARCJONES
200A Main Breaker #6 THWN DESC.: 11.01 kW solar panel system
240v 240V AC CONSTRUCTION Sch 80 PVC UTILITY: FPL
e.�de�r;ai �o�me.��ai .oia.
JURISDICTION: St. Lucie
S U N P R DATE: 9.29.20 REV: 1 1 SHEET: 1 OF 1
SOLAR 41OML SPFCtAusTS layout One-Line
Designer: ... Designer: C.Rosevally