HomeMy WebLinkAboutAPPROVED NOA MIAMI•DADE MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.Eov/economy
Johns Manville Corporation
717 17th Street
Denver,CO 80202
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product
Control Section(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product
or material fails to perform in the accepted manner,the manufacturer will incur the expense of such
testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material
within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Johns Manville Modified Bitumen Roofing Systems over Concrete Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and
following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed,then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 13-0529.19 and consists of pages 1 through 84.
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No.: 16-0413.22
MIAMI•DADE COYVTYB Expiration Date: 07/19/21
• Approval Date: 07/14/16
Page 1 of 84
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub-Category: Modified Bitumen
Materials• SBS
Deck Type: Concrete
Maximum Design Pressure: -536.5 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product Dimensions Specification Product Description
JM BaseGrip SD/SA 36" x 72' ASTM D4601 Glass reinforced, self-adhering SBS
modified bitumen base sheet
DynaBase 39-3/8"x 49'2" ASTM D 6163 A glass reinforced SBS modified bitumen
base sheet.
DynaBase HW 39-3/8"x 49'2" ASTM D 6163 A glass reinforced SBS modified bitumen
base sheet for heat welded applications.
DynaBase PR 39-3/8"x 49'2" ASTM D6164 A polyester reinforced SBS modified
bitumen base sheet.
DynaBase XT 39-3/8" x 49'-2" ASTM D 6163 A glass reinforced SBS modified bitumen
base or inner ply sheet.
DynaClad 39-3/8"x 33'10" ASTM D6298 A glass reinforced base sheet SBS modified
bitumen membrane surfaced with foil.
DynaFast 180 HW 39-3/8"x 49'2" ASTM D6164 A polyester reinforced SBS modified
bitumen base or inner ply sheet for use in
heat weld applications.
DynaFast 180 S 39-3/8"x 49'2" ASTM D6164 A polyester reinforced SBS modified
bitumen base or inner ply sheet.
DynaFast 250 HW 39-3/8"x 32'10" ASTM D6164 A polyester reinforced SBS modified
bitumen base or inner ply sheet for use in
heat weld applications.
DynaGlas 39-3/8" x 32'-10" ASTM D6163 A glass reinforced SBS modified bitumen
membrane surfaced with granules.
DynaGlas 30 FR 39-3/8"x 32'-10" ASTM D6163 A fire resistant, glass reinforced SBS
modified bitumen membrane surfaced with
granules.
DynaGlas FR 39-3/8"x 32'-10" ASTM D6163 A fire resistant, glass reinforced SBS
modified bitumen membrane surfaced with
granules.
DynaGlas FR CR 39-3/8" x 32'-10"; ASTM D6163 A fire resistant, glass reinforced SBS
modified bitumen membrane surfaced with
granules and a reflective white coating for
use in heat weld applications.
DynaGlas FR CR G 39-3/8" x 32'10" ASTM D 6163 A fire resistant, glass reinforced SBS
modified bitumen membrane surfaced with
granules and cool roof coating.
NOA No.: 16-0413.22
MIAMI•DADE COYVTYB Expiration Date: 07/19/21
• Approval Date: 07/14/16
Page 2 of 84
Test
Product Dimensions Specification Product Description
DynaGlas FR XT 39-3/8"x 32'-10" ASTM D6163 A fire resistant, glass reinforced SBS
modified bitumen membrane surfaced with
granules.
DynaGrip Base 39-3/8" x 65'-7" ASTM D4601 Glass reinforced, self-adhering SBS
SD/SA modified bitumen base sheet
DynaKap FR T1 39-3/8"x 32'-10" ASTM D6162 A fire resistant, composite reinforced SBS
modified bitumen membrane surfaced with
granules.
DynaKap FR T1 CR 39-3/8"x 32'10" ASTM D6162 A fire resistant, composite reinforced SBS
G modified bitumen membrane surfaced with
granules and cool roof coating.
DynaKap FR T1 HW 39-3/8"x 32'10" ASTM D6162 A fire resistant, composite reinforced SBS
CR G modified bitumen membrane surfaced with
granules with cool roof coating for use in
heat weld applications.
DynaLastic 180 39-3/8" x 32'-10" ASTM D6164 A polyester reinforced SBS modified
bitumen membrane surfaced with granules.
DynaLastic 180 FR 39-3/8"x 32'-10" ASTM D6164 A fire resistant,polyester reinforced SBS
modified bitumen membrane surfaced with
granules.
DynaLastic 180 FR 39-3/8"x 32'-10" ASTM D6164 A fire resistant,polyester reinforced SBS
CR modified bitumen membrane surfaced with
granules.
DynaLastic 180 FR 39-3/8" x 32'10" ASTM D6164 A fire resistant,polyester reinforced SBS
CR G modified bitumen membrane surfaced with
granules and cool roof coating.
DynaLastic 180 S 39-3/8" x 32'10" ASTM D6164 A polyester reinforced SBS modified
bitumen base or inner ply sheet.
DynaLastic 250 FR 39-3/8" x 32'-10" ASTM D6164 A fire resistant,polyester reinforced SBS
modified bitumen membrane surfaced with
granules.
DynaLastic 250 FR 39-3/8"x 32'-10" ASTM D6164 A fire resistant,polyester reinforced SBS
CR modified bitumen membrane surfaced with
granules and a reflective white coating.
DynaLastic 250 FR 39-3/8" x 32'10" ASTM D6164 A fire resistant,polyester reinforced SBS
CR G modified bitumen membrane surfaced with
granules, cool roof coating and a reflective
white coating.
DynaLastic 250 S 39-3/8" x 32'-10" ASTM D 6164 A polyester reinforced SBS modified
bitumen base or inner ply sheet.
DynaMax FR 39-3/8"x 32'-10" ASTM D6162 A fire resistant, composite reinforced SBS
modified bitumen membrane surfaced with
granules.
DynaMax FR Plus 39-3/8"x 32'-10" ASTM D6162 A fire resistant, composite reinforced SBS
modified bitumen membrane surfaced with
granules.
NOA No.: 16-0413.22
MIAMI•DADE COYVTYA Expiration Date: 07/19/21
• Approval Date: 07/14/16
Page 3 of 84
Test
Product Dimensions Specification Product Description
DynaMax FR HW 39-3/8"x 32'-10" ASTM D6162 A fire resistant, composite reinforced SBS
modified bitumen membrane surfaced with
granules.
DynaMax FR HW 39-3/8" x 32'-10" ASTM D6162 A fire resistant, composite reinforced SBS
CR modified bitumen membrane surfaced with
granules.
DynaMax FR CR 39-3/8"x 32'-10" ASTM D6162 A fire resistant, composite reinforced SBS
modified bitumen membrane surfaced with
granules.
DynaMax S 39-3/8"x 32'-10" ASTM D6162 A composite reinforced SBS modified
bitumen base or inner ply sheet.
DynaPly T1 39-3/8"x 32'-10" ASTM D6162 A composite reinforced SBS modified
bitumen base or inner ply sheet.
DynaWeld 180 S 39-3/8"x 32'-10" ASTM D6162 A polyester reinforced SBS modified
bitumen base or inner ply sheet for use in
heat weld applications.
DynaWeld 250 S 39-3/8" x 32'-10" ASTM D6164 A polyester reinforced SBS modified
bitumen base or inner ply sheet for use in
heat weld applications.
DynaWeld Base 39'-3/8"x 32'-10" ASTM D6163 A glass reinforced SBS modified bitumen
base sheet for heat welded applications.
DynaWeld Cap 180 39-3/8"x 32'-10" ASTM D6164 A fire resistant,polyester reinforced SBS
FR modified bitumen membrane surfaced with
granules for use in heat weld applications.
DynaWeld Cap 180 39-3/8"x 32'-10" ASTM D6164 A fire resistant,polyester reinforced SBS
FR CR modified bitumen membrane surfaced with
granules for use in heat weld applications.
DynaWeld Cap 250 39-3/8" x 32'-10" ASTM D6164 A polyester reinforced SBS modified
bitumen membrane surfaced with granules
for use in heat weld applications.
DynaWeld Cap 250 39-3/8"x 32'-10" ASTM D6164 A fire resistant,polyester reinforced SBS
FR modified bitumen membrane surfaced with
granules for use in heat weld applications.
DynaWeld Cap 250 39-3/8"x 32'-10" ASTM D6164 A fire resistant,polyester reinforced SBS
FR CR modified bitumen membrane surfaced with
granules and a reflective white coating for
use in heat weld applications.
DynaWeld Cap 250 39-3/8"x 32'10" ASTM D6164 A fire resistant,polyester reinforced SBS
FR CR G modified bitumen membrane surfaced with
granules, cool roof coating and a reflective
white coating for use in heat weld
applications.
DynaWeld Cap FR 39'-3/8"x 32'-10" ASTM D6163 A fire resistant, glass reinforced SBS
modified bitumen membrane surfaced with
granules for use in heat weld applications.
DynaWeld Cap FR 39'-3/8"x 32'-10" ASTM D6163 A fire resistant,polyester reinforced SBS
XT modified bitumen membrane surfaced with
granules for use in heat weld applications.
NOA No.: 16-0413.22
MIAMI•DADE COYVTYA Expiration Date: 07/19/21
• Approval Date: 07/14/16
Page 4 of 84
Test
Product Dimensions Specification Product Description
DynaWeld Cap FR 39'-3/8"x 32'-10" ASTM D6163 A fire resistant,polyester reinforced SBS
CR modified bitumen membrane surfaced with
granules and a reflective white coating for
use in heat weld applications.
DynaWeld Cap FR 39-3/8"x 32'10" ASTM D6163 A fire resistant,polyester reinforced SBS
CR G modified bitumen membrane surfaced with
granules, cool roof coating and a white
reflective coating for use in heat weld
applications.
G1asBase Plus 36" x 108' ASTM D4601 Type II asphalt impregnated and coated
glass fiber base sheet for use in
conventional and modified bitumen built-up
roofing.
G1asKap 36"x 36' ASTM D3909 A mineral surfaced, asphalt coated,
fiberglass cap sheet.
G1asKap CR 36"x 36' ASTM D3909 A white mineral surfaced,white acrylic
coated, fiberglass cap sheet.
G1asKap Plus 36"x 36' ASTM D3909 A mineral surfaced, asphalt coated,
fiberglass cap sheet.
G1asPly IV 36"x 180' ASTM D2178 Type IV asphalt impregnated glass felt for
use in conventional and modified bitumen
built-up roofing.
GlasPly Premier 36"x 180' ASTM D2178 Type VI asphalt impregnated glass felt for
use in conventional and modified bitumen
built-up roofing.
PermaPly 28 36"x 106' ASTM D4601 Type II asphalt impregnated and coated
glass fiber base sheet for use in
conventional and modified bitumen built-up
roofing.
Ventsulation Felt 36" x 36' ASTM D4897 Heavy duty fiber glass base sheet
impregnated and coated on both sides with
asphalt with or without fine mineral
stabilizer. Surfaced on the bottom side with
coarse mineral granules embedded in
asphaltic coating.
FesCant Plus Cant various ASTM C728 Factory pre-fabricated cant strips and taper
Strips, and Taper edge,manufactured from expanded perlite
Edge insulation.
MBR Flashing N/A Proprietary A two component elastomeric, cold
Cement Base and application adhesive, consisting of a
Activator modified proprietary compound with an
asphalt base.
MBR Bonding N/A proprietary A two component urethane cold application
Adhesive adhesive.
MBR Cold 5, 55,and 350 gal. ASTM D3019 One part, elastomeric cold application
Application Type III adhesive
Adhesive
NOA No.: 16-0413.22
MIAMI•DADE COYVTYB Expiration Date: 07/19/21
• Approval Date: 07/14/16
Page 5 of 84
Test
Product Dimensions Specification Product Description
Urethane Insulation N/A Proprietary Urethane insulation adhesive.
Adhesive
JM Roofing System Various Proprietary A two-component, cold-applied adhesive
Urethane Adhesive
JM Two Part Various Proprietary A two-component, cold-applied adhesive
Urethane Insulation
Adhesive
One-Step Foamable N/A Proprietary A two-part urethane insulation adhesive
Adhesive
Bestile Industrial various ASTM D4586 A trowel grade, cutback bitumen flashing
Roof Cement Type I grade cement mixture including inorganic
fibers and mineral stabilizers.
Flex-I-Drain various BOCA 76-61, Two-piece flexible drain system composed
SBCCI 89204, of a Noryl deck flange,a flexible neoprene
UBC 3236 bellows and no hub connection. Available
in various sizes and styles for most retro-fit
applications.
PC/PET RetroDrain various N/A Engineered resin copolymer fabricated drain
for retrofit applications.
USII RetroDrain various N/A One piece, aluminum fabricated drain for
retrofit applications.
Superpome various N/A Cast aluminum,heavy-duty drain for retrofit
RetroDrain applications.
FP-10 Vents 10" deck flange, N/A One-way roof vent, designed for use in
base diameter of 4" various roof systems, for the release of
and a height of 6" pressure created by gases or moisture vapor
trapped within the roofing system.
Expand-O-Guard various N/A Elastomeric expansion joint cover for
vertical expansion and seismic joints.
Manufactured from non-reinforced, form-
supported elastomeric bellows with a
bifurcated waterproof attachment to metal
flanges.
Expand-O-Flash various N/A Expansion joint covers manufactured from
non-reinforced, form-supported elastomeric
bellows with a bifurcated waterproof
attachment to metal flanges.
Presto-Lok Fascia various TAS 114 A multi-piece fascia and flashing system for
and Flashing System built-up and modified bitumen roofing
systems manufactured from aluminum or
steel.
DynaTred& various N/A Preformed, skid-resistant boards.
DynaTred Plus Roof
Walkway
NOA No.: 16-0413.22
MIAMI•DADE COYVTYB Expiration Date: 07/19/21
• Approval Date: 07/14/16
Page 6 of 84
APPROVED INSULATIONS:
TABLE 2
Product Name Product Description Manufacturer
(With Current NOA)
ENRGY 3,ENRGY 3 25 PSI, Polyisocyanurate Insulation. Johns Manville
ValuTherm,ValuTherm 25 PSI,
R-Panel,R-Panel 25 PSI,ENRGY 3.E
ENRGY 3 AGF, ENRGY 3 AGF 25 PSI, Isocyanurate Insulation with glass Johns Manville
ENRGY 3 CGF,ENRGY 3 CGF 25 PSI, reinforced facers
ValuTherm AGF,ValuTherm AGF 25 PSI,
ValuTherm CGF,ValuTherm CGF 25 PSI
ENRGY 3 FR,ENRGY 3 FR 25 PSI Isocyanurate Insulation with Johns Manville
inorganic coated glass reinforced
facers;bottom face is premium
coated for combustible decks.
Fesco Foam, DuraFoam Polyisocyanurate Insulation with Johns Manville
perlite facer
Retro-Fit Board,DuraBoard, RetroPlus High-density perlite roof insulation. Johns Manville
Roof Board
Fesco Board Rigid perlite roof insulation board. Johns Manville
JM SECUROCK Gypsum-Fiber Roof Rigid,gypsum-based board stock Johns Manville
Board
Invinsa Roof Board High density polyisocyanurate board Johns Manville
APPROVED FASTENERS:
TABLE 3
Fastener Product Product Manufacturer
Number Name Description Dimensions (With Current NOA)
1. All Purpose Fastener Insulation fastener for #14 x 16"max. Johns Manville
concrete decks. length; #3 Phillips
head
2. Structural Concrete Deck Insulation fastener for Various Johns Manville
Fastener concrete decks.
3. UltraFast 3"Round Galvalume AZ55 3"round Johns Manville
Metal Plate or U1traFast steel plate 3" square
Square Recessed Metal
Plate
4. High Load Plates Galvalume steel plate 2-3/8" Johns Manville
NOA No.: 16-0413.22
MIAMI•DADE COYVTYB Expiration Date: 07/19/21
• Approval Date: 07/14/16
Page 7 of 84
EVIDENCE SUBMITTED:
Test Agency/Identifier Name Report Date
Factory Mutual Research Corp. 3001482 FM 4470 08/11/98
3001629 FM 4470 09/10/98
OZ8A9.AM FM 4470 09/10/98
3D4A4.AM FM 4470 09/28/98
3007148 FM 4450 04/19/00
3006346 FM 4450 09/15/00
3001457 FM 4470 03/04/02
3009499 FM 4470 04/04/01
3011248 FM 4470 11/01/02
3014090 FM 4470 09/05/02
3012974 FM 4450 06/03/02
3037222 FM 4470 10/02/09
3026130 FM 4470 04/26/09
3037540 FM 4470 10/20/10
3012064 FM 4470 06/25/02
3053754 FM 4470 03/04/15
3040986 FM 4470 09/23/11
3054150 FM 4470 05/13/15
3036559 FM 4470 10/02/09
3046174 FM 4470 04/03/13
3004299 FM 4470 10/02/01
3043824 FM 4470 06/04/12
3023458 FM 4470 07/18/06
3040986 FM 4470 09/23/11
3052113 FM 4470 08/29/14
RR205623 FM 4470 07/08/16
Dynatech Engineering, Inc. 4361.5.95-1 TAS 114 05/95
Underwriters Laboratories,Inc. R10167 UL 790 05/27/13
Exterior Research&Design,LLC #10390A-12.97-1 TAS 114 12/97
10391.01.03 TAS 114 01/29/03
02843.02.05-10-R1 TAS 114 02/07/07
02843.02.07 TAS 114 02/07/07
Trinity) ERD J7670.06.08 ASTM D3909 06/16/08
J6990.12.07-R1 ASTM D6162/D6164 03/24/10
J13700.05.10-1-R1 ASTM D6163 01/25/11
J17040.11.09-R1 ASTM D6164 03/11/10
JM-11190.03.16 TAS 114(J) 03/11/16
JM-SC11320.03.16 TAS 114 (D) 03/10/16
J45020.07.13 TAS 114 07/12/13
Independent Roof Testing& IRT 99006 TAS 114 01/20/99
Consultants of South Florida IRT 99007 TAS 114 01/20/99
IRT 99008 TAS 114 01/20/99
IRT 99016 TAS 114 01/20/99
IRT 99009 TAS 114 02/10/99
IRT 99010 TAS 114 02/10/99
IRT-ARCON Inc. 02-026 TAS 114 07/26/02
02-011 TAS 114 02/06/02
NOA No.: 16-0413.22
MIAMI•DADE COYVTYA Expiration Date: 07/19/21
�gjjms Approval Date: 07/14/16
Page 8 of 84
EVIDENCE SUBMITTED: (CONTINUED)
Test Agency/Identifier Name Report Date
Atlantic &Caribbean Roof ACRC 06-003 TAS 114 03/27/06
Consulting,LLC ACRC 06-009 TAS 114 06/28/06
PRI Construction Materials JMC-063-02-01 ASTM D6163 06/11/12
Technologies, LLC JMC-065-02-01 ASTM D6163 05/29/12
JMC-066-02-01 ASTM D6163 06/04/12
JMC-069-02-01 ASTM D3909 06/04/12
JMC-070-02-01 ASTM D2178 04/17/12
JMC-071-02-01 ASTM D2178 04/17/12
JMC-072-02-02.1 ASTM D4601 05/25/16
JMC-074-02-01 ASTM D4897 04/17/12
JMC-075-02-04.3 ASTM D6164 03/29/16
JMC-076-02-02 ASTM D4601 04/17/12
JMC-078-02-01 ASTM D6298 07/17/12
JMC-081-02-01.02 TAS 117 B &C 06/11/12
JMC-091-02-01.1 ASTM D4601 05/26/16
JMC-093-02-01 ASTM D4601 08/02/12
JMC-105-02-02 Rev 1 ASTM D6162 05/22/13
JMC-106-02-01 ASTM D6164 04/15/13
JMC-107-02-01.7 ASTM D903/D 1 876/D5147 03/31/16
TAS 114(C)/TAS 117 A&B
JMC-108-02-01 TAS 114 (J) 04/16/13
JMC-113-02-01 ASTM D6164 04/19/13
JMC-114-02-01 TAS 114 (J) 08/20/13
JMC-141-02-01 TAS 114 (J) 04/18/13
JMC-147-02-01 ASTM D4601 05/28/13
JMC-168-02-01 TAS 114 (J) 08/20/13
JMC-171-02-01 ASTM D6163 01/10/14
JMC-171-02-02 ASTM D6163 01/10/14
JMC-171-02-03 ASTM D6164 01/10/14
JMC-171-02-04.1 ASTM D6163 05/26/16
JMC-171-02-07.1 ASTM D6164 05/26/16
JMC-171-02-10 ASTM D6162 01/10/14
JMC-171-02-11 ASTM D6164 03/14/14
JMC-227-02-01.3 ASTM D6162 06/29/16
JMC-234-02-01.2 ASTM D6162 06/29/16
JMC-234-02-02 ASTM D6163 04/29/15
JMC-234-02-03.1 ASTM D6163 05/26/16
JMC-234-02-04 ASTM D6162 03/23/16
JMC-234-02-05 ASTM D6164 04/29/15
JMC-234-02-06.1 ASTM D6164 05/26/16
JMC-238-02-01.1 ASTM D6163 06/29/16
JMC-238-02-03 ASTM D6164 12/01/15
JMC-238-02-04 ASTM D6162 03/31/16
JMC-243-02-01 ASTM 135147/134798 02/29/16
JMC-268-02-01 TAS 114 (J) 03/30/16
JMC-272-02-01 TAS 114 (J) 04/07/16
ADCO-001-02-01 Physical Properties 06/16/13
NOA No.: 16-0413.22
MIAMI•DADE COYVTYB Expiration Date: 07/19/21
• Approval Date: 07/14/16
Page 9 of 84
Membrane Type: SBS
Deck Type 3I: Concrete Decks, Insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A(11): Insulation adhered to deck in insulation adhesive. Membrane is subsequently
fully adhered.
All General and System limitations apply.
One or more layers of the following insulations:
Base Insulation Layer(Optional) Insulation Fasteners Fastener
(Table 3) Density/ft2
ENRGY 3,ENRGY 3 25 PSI,ValuTherm,ValuTherm 25 PSI,R-Panel,R-Panel 25 PSI,ENRGY 3
AGF, ENRGY 3 AGF 25 PSI,ValuTherm AGF,ValuTherm AGF 25 PSI,ENRGY 3 CGF,
ENRGY 3 CGF 25 PSI,ValuTherm CGF,ValuTherm CGF 25 PSI
Minimum 2"thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
SECUROCK Gypsum-Fiber Roof Board
Minimum 1/"thick N/A N/A
Note: Insulation shall be adhered with JM Two Part Urethane Insulation Adhesive or JM Roofing
System Urethane Adhesive in 1/4"to 1"wide beads at maximum spacing of 12" o.c. or with MBR
Bonding Adhesive at an application rate of 1.5 gal./sq. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
Base Sheet: (Optional)One ply of PermaPly 28,DynaBase,DynaBase PR, DynaBase XT,
DynaLastic 180 S,DynaFast 180 S, DynaPly T1,DynaLastic 250 S,DynaMax S
or G1asBase Plus adhered to the insulated substrate in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or with MBR
Bonding Adhesive at an application rate of 1.5 gal./sq.
Ply Sheet: One or more plies of GlasBase Plus,PermaPly 28,G1asPly Premier, GlasPly IV,
DynaLastic 180 S,DynaFast 180 S, DynaLastic 250 S,DynaBase,DynaBase PR,
DynaBase XT, DynaMax S or DynaPly T1 adhered to the base sheet with
approved mopping of asphalt applied within the EVT range and at a rate of 20-40
lbs./sq. or with MBR Bonding Adhesive at an application rate of 1.5 gal./sq. or one
ply DynaWeld Base,DynaBase HW,DynaWeld 180 S,DynaFast 180 HW,
DynaWeld 250 S or DynaFast 250 HW heat welded.
Membrane: One ply of DynaGlas 30 FR,DynaGlas,DynaGlas FR CR,DynaGlas FR,
DynaGlas FR CR G, DynaLastic 180,DynaLastic 180 FR,DynaLastic 180 FR CR,
DynaLastic 180 FR CR G, DynaGlas FR XT,DynaKap FR T1, DynaKap FR T1
CR G,DynaLastic 250 FR,DynaLastic 250 FR CR, DynaLastic 250 FR CR G,
DynaMax FR, DynaMax FR CR, or DynaMax FR adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or
with MBR Bonding Adhesive at an application rate of 1.5 gal./sq. or one ply
DynaWeld Cap FR, DynaWeld Cap FR CR,DynaWeld Cap FR CR G,DynaWeld
Cap 180 FR CR,DynaWeld Cap 180 FR, DynaWeld Cap FR XT,DynaWeld Cap
250, DynaWeld Cap 250 FR,DynaWeld Cap 250 FR CR,DynaWeld Cap 250 FR
CR G,DynaKap FR T1 HW CR G, DynaMax FR HW, or DynaMax FR HW CR
heat welded..
Or
(Requires to be used with a Modified Bitumen Ply Sheet listed above.) GlasKap,
GlasKap Plus or GlasKap CR adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq.
NOA No.: 16-0413.22
MIAMI•DADE COYVTYB Expiration Date: 07/19/21
• Approval Date: 07/14/16
Page 25 of 84
Surfacing: (Optional) Install one of the following:
1. Flood coat and gravel/slag with an application rate of 60 lbs./sq. &400 lbs./sq.
2. (Optional with FR membranes)Henry 280 in two coats applied at a rate of 1.0
gal./sq./coat.
Maximum Design -442.5 ps£with JM Two Part Adhesive(except AGF)(See General Limitation#9)
Pressure: -397.5 ps£ for AGF boards with JM Two Part Adhesive(See General Limitation#9)
-367.5 ps£with MBR Bonding Adhesive(See General Limitation#9)
NOA No.: 16-0413.22
MIAMI•DADE C0YVTYA Expiration Date: 07/19/21
• Approval Date: 07/14/16
Page 26 of 84
CONCRETE DECK SYSTEM LIMITATIONS:
1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed,a
field withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener
patterns and density. All testing and fastening design shall be in compliance with Testing Application
Standard TAS 105 and Roofing Application Standard RAS 117; calculations shall be signed and sealed
by a Florida Registered Engineer,Architect, or Registered Roof Consultant.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory
for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-401bs./sq., or mechanically attached using the
fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt,
panel size shall be 4'x 4'maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam
insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be
applied using spot mopping with approved asphalt, 12" diameter circles,24" o.c.; or strip mopped 8"
ribbons in three rows,one at each side lap and one down the center of the sheet allowing a continuous
area of ventilation. Encircling of the strips is not acceptable. A 6"break shall be placed every 12'in
each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate
of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of-45
psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275
lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-
tested, are below 2751bf. Insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a
minimum fastener resistance value in conjunction with the maximum design value listed within a
specific system. Should the fastener resistance be less than that required, as determined by the Building
Official, a revised fastener spacing,prepared, signed and sealed by a Florida Registered Engineer,
Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize
the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in
compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas.
Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with
Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered
Professional Engineer,Registered Architect,or Registered Roof Consultant(When this limitation is
specifically referred within this NOA,General Limitation#9 will not be applicable.)
8. All attachment and sizing of perimeter nailers,metal profile, and/or flashing termination designs shall
conform to Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field,
perimeters, and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced
fastening at enhanced pressure zones (i.e.perimeters, extended corners and corners). (When this
limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 16-0413.22
MIAMI•DADE COYVTYB Expiration Date: 07/19/21
• Approval Date: 07/14/16
Page 84 of 84