Loading...
HomeMy WebLinkAboutCover, Arch, WP, Ele, Plu [ds] 10.9.2020K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______THESE PLANS HAVE BEEN PREPARED TO MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, 6th Edition (2017) RESIDENTIAL w/ APPLICABLE SUPPLEMENTS OCCUPANCY: R3 BUILDING TYPE: VB SPRINKLED: NO FLOOD ZONE: ’X’ TERMITE PROBABILITY: VERY HEAVY LOT 013 ABBREVIATIONS MAS MAT MAX MC MIN M.O. MTL N.I.C. (NTS) OHGD OPER OPNG OPT OSB OZ 1/R 1/S PC PNL PLYWD PREFAB PR PROJ PSI PSF P.T. QUAD REF REINF REQ’D RNG R.O. R RND MASONRY ML MATERIAL MAXIMUM MEDICINE CABINET MINIMUM MICRO LAM MASONRY OPENING METAL NOT IN CONTRACT NOT TO SCALE OVERHEAD GARAGE DOOR OPERATOR OPENING OPTIONAL ORIENTED STRAND BOARD OUNCE ONE ROD ONE SHELF PRECAST PANEL PLYWOOD PREFABRICATED PAIR PROJECTED POUNDS PER SQUARE INCH POUNDS PRE SQUARE FOOT PRESSURE TREATED QUADRUPLE REFRIGERATOR REINFORCED REQUIRED RANGE ROUGH OPENING RISER ROUND MECH MECHANICAL MIR MIRROR AB A.F.F. ADJ. ALUM. ANCH @ BD. BLDG. BM. BLKG BRG. BRK. C.J. CMU COL. CONC. COND. CONT. CANT. CLG. CM CR D d DBL. DIA. DIR. DN DR DW DWG D.S. DTL EA. E.J. ELEC. CL BF ANCHOR BOLT ABOVE FINISH FLOOR ADJUSTABLE ALUMINUM ANCHOR ANGLE AT BOARD BI−FOLD BUILDING BEAM BLOCKING BEARING BRICK CONTROL JOINT CENTER LINE CONCRETE MASONRY UNIT COLUMN CONCRETE CONDITION CONTINUOUS CANTILEVER CEILING CROWN MOLDING CHAIR RAIL DRYER PENNY DOUBLE DIAMETER DIRECTION DOWN DOOR DISH WASHER DRAWING DOWNSPOUT DETAIL EACH EXPANSION JOINT ELECTRICAL B.O.BOTTOM OF O.C.ON CENTER PKT POCKET DOOR OBS OBSCUREDB.P.BI−PASS DOOR PDS PULL−DOWN STAIR FD FND. FLR. FP FR FRM FTG GA. GALV. GC GEN GYP. GL HGT. HDR. HB INSUL. INT. LT FLOOR DRAIN FOUNDATION FLOOR FIREPLACE FIRE RATED FRAME FOOTING GAUGE GALVANIZED GENERAL CONTRACTOR GENERAL GYPSUM GLUE LAM HEIGHT HEADER HOSE BIBB INSULATION INTERIOR LAUNDRY TUB HC HOLLOW CORE HORIZ.HORIZONTAL FINISHED FLOORFIN. LAVATORYLAV. ELEV EQ. EQUIP. EXP EXT. EE ELEVATION EQUAL EQUIPMENT EXPANSION EXTERIOR EACH END FXD FIXED GLS GLASS H HIGH R&S SC SCHEM SHLF SHT SIM S.S. STL STRUCT SUSP SGD SQ TB T&G TYP T TR TRPL U.N.O. VERT V.L.I.F. W W/ WD WWM WDW ROD AND SHELF SOLID CORE SCHEMATIC SHELF SHEET SIMILAR STAINLESS STEEL STEEL STRUCTURAL SUSPENSION SLIDING GLASS DOOR SQUARE TOWEL BAR TONGUE AND GROOVE TYPICAL TREAD TOWEL ROD TRIPLE UNLESS NOTED OTHERWISE VERTICAL VERIFY LOCATION IN FIELD WASHER WITH WOOD WELD WIRE MESH WINDOW WC WATER CLOSET SINGLE HUNGSH SHOWERSHWR TEMP TEMPERED T.O.TOP OF RELEASE HISTORY TERMITE PROTECTION SHALL BE PROVIDED BY DOMINION 2L TERMITICIDE/INSECTICIDE. UPON COMPLETION OF THE APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." 90 Matawan Road Matawan, NJ 07747 (732) 383−2200 TM FRONT & REAR ELEVATIONS FIRST FLOOR PLAN COVERSHEET & BUILDING DATA A−2.1 A−1.1 CS.1 CS.2 A−2.2 ROOF PLAN A−5.1 BUILDING SECTIONS A−5.2 TYPICAL WALL SECTIONS GENERAL NOTES DRAWING INDEX FIRST FLOOR ELECTRICAL PLANE−1.1 SLAB PENETRATION PLANP−1.1 SIDE ELEVATIONS A−3.1 STRUCTURAL NOTESS−0.0 F−1.0 BLOCK PLAN S−1.3 ROOF FRAMING PLAN SD−1 FOUNDATION DETAILS STRUCTURAL DETAILSSD−2 SLAB PLAN F−2.0 STRUCTURAL DETAILSPBSB−1 WP−1 WATERPROOFING DETAILS 1917 SQ. FT. 380 SQ. FT. "B"ELEVATION 1ST FLR/TOTAL A/C ENTRY GARAGE TOTAL UR 2381 SQ. FT. 84 SQ. FT. CS1COVER SHEET &BUILDING DATA16,614 CU. FT.TOTAL VOLUME 1. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS THAN 1/2 INCH (12.7 mm) GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5/8 INCH (15.9 mm) TYPE "X" GYPSUM BOARD OR EQUIVALENT. WHERE THE SEPARATION IS A FLOOR-CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN 1/2 INCH (12.7 mm) GYPSUM BOARD OR EQUIVALENT. 1. SHALL BE 5/8" THICK TEXTURED PER COMMUNITY STANDARDS. 2. SHALL BE 7/8" THICK (3) COAT STUCCO OVER (2) LAYERS OF WATER RESISTANT BARRIERS IN ACCORDANCE WITH FLORIDA BUILDING CODE 6TH EDITION (2017) RESIDENTIAL, R703 AND ASTM C926. TEXTURE PER COMMUNITY 1. FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, DECK AND WALL INTERSECTIONS, AT GUTTERS, AT ALL CHANGES IN ROOF SLOPE OR DIRECTION, AND AROUND ROOF OPENINGS. 2. APPROVED CORROSION-RESISTANT FLASHING SHALL BE APPLIED SHINGLE-FASHION IN A MANNER TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. SELF-ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORROSION-RESISTANT FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: 3. EXTERIOR WINDOW AND DOOR OPENINGS . FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER-RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE FOLLOWING: ·THE FENESTRATION MANUFACTURER’S INSTALLATION AND FLASHING INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESSED IN THE FENESTRATION MANUFACTURER’S INSTRUCTIONS, IN ACCORDANCE WITH THE FLASHING MANUFACTURER’S INSTRUCTIONS. WHERE FLASHING INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PAN FLASHING SHALL BE INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER−RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN FLASHING SHALL ALSO INCORPORATE FLASHING OR PROTECTION AT THE HEAD AND SIDES. ·IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN PROFESSIONAL. ·IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200. FMA/WDMA 250, OR FMA/AAMA/WDMA 300 1. WINDOWS SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. WRITTEN INSTALLATION INSTRUCTIONS SHALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW. : PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGE FLOOR ELEVATION. : 1. WIND RESISTANCE OF ASPHALT SHINGLES. - ASPHALT SHINGLES SHALL BE INSTALLED IN ACCORDANCE WITH SECTION R905.2.6 AND R905.2.6.1. : 1. WHEN STANDARD OR OPTIONAL FIREPLACE IS TO BE INSTALLED THE CHIMNEY MUST EXTEND 3'-0" PAST THE HIGHER POINT WHERE IT EXTENDS THROUGH THE ROOF AND MUST BE 2'-0" HIGHER THAN THE ROOF OR RIDGE THAT IS 10'-0" AWAY OR CLOSER. : 1. CEMENT, FIBER-CEMENT, OR GLASS MAT GYPSUM BOARD (NO GREEN BOARD ALLOWED) IN COMPLIANCE WITH ASTM C1288, C1325, OR C1178 AND INSTALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS SHALL BE USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS, AND WALL PANELS IN SHOWER AREAS. : 1. ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES SHALL BE FURNISHED BY THE GENERAL CONTRACTOR AS AN ATTACHMENT TO THIS PLAN SET AT THE TIME OF APPLICATION FOR PERMIT. 2. MECHANICAL APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION, OTHER APPLIANCES, OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE BEING INSPECTED, SERVICED, REPAIRED, OR REPLACED. A LEVEL WORKING SPACE AT LEAST 30 INCHES (762 mm) DEEP AND 30 INCHES (762 mm) WIDE SHALL BE PROVIDED IN FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE. 3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MIN. #26 GAUGE (0.48 mm) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. 4. FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE RAISED AT LEAST 3 INCHES (76 mm) ABOVE THE FINISHED GRADE AND SHALL ALSO CONFORM TO THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 5. AUXILIARY DRAIN PAN. CATEGORY IV CONDENSING APPLIANCES SHALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO ANY BUILDING COMPONENT WILL OCCUR AS A RESULT OF STOPPAGE IN THE CONDENSATE DRAIN PIPING SYSTEM. THESE PANS SHALL BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF SECTIONS M1411.3. : 1. OUTDOOR DISCHARGE. THE AIR REMOVED BY EVERY MECHANICAL EXHAUST SYSTEM SHALL BE DISCHARGED TO THE OUTDOORS. AIR SHALL NOT BE EXHAUSTED INTO AN ATTIC, SOFFIT, RIDGE VENT OR CRAWL SPACE. 2. EXHAUST AIR FROM BATH ROOMS AND TOILET ROOMS SHALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND SHALL BE EXHAUSTED DIRECTLY TO THE OUTDOORS. EXHAUST AIR FROM BATHROOMS AND TOILET ROOMS SHALL NOT DISCHARGE INTO AN ATTIC, CRAWL SPACE, OR OTHER AREAS INSIDE THE BUILDING. 3. DUCT LENGTH : THE MAXIMUM LENGTH OF A CLOTHES: DRYER EXHAUST DUCT SHALL NOT EXCEED 35 FEET . THE DRYER LOCATION TO THE WALL OR ROOF TERMINATION. THE MAXIMUM LENGTH OF THE DUCT SHALL BE REDUCED 2.5 FEET (762 mm) FOR EACH 45 DEGREE (0.79 RAD) BEND AND 5 FEET (1524 mm) FOR EACH 90 DEGREE (1.6 RAD) BEND. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT. EXCEPTION - WHERE A CLOTHES DRYER BOOSTER FAN IS INSTALLED AND LISTED AND LABELED FOR THE APPLICATION, THE MAXIMUM LENGTH OF THE EXHAUST DUCT, INCLUDING ANY TRANSITION DUCT, SHALL BE PERMITTED TO BE IN ACCORDANCE WITH THE BOOSTER FAN MANUFACTURER'S INSTALLATION INSTRUCTIONS. WHERE A CLOTHES DRYER BOOSTER FAN IS INSTALLED AND NOT READILY ACCESSIBLE FROM THE ROOM IN WHICH THE DRYER IS LOCATED, A PERMANENT IDENTIFYING LABEL SHALL BE PLACED ADJACENT TO WHERE THE EXHAUST DUCT ENTERS THE WALL. THE LABEL SHALL BEAR THE WORDS "THIS DRYER EXHAUST SYSTEM IS EQUIPPED WITH A REMOTELY LOCATED BOOSTER FAN." 4. PROVIDE LOUVER DEVICES AT INTAKE AND EXHAUST LOCATIONS IN ACCORDANCE WITH AMCA STANDARD 550 IN FBC. : ISSUANCE OF PLANS FROM THIS OFFICE SHALL NOT RELIEVE THE BUILDER OF RESPONSIBILITY TO REVIEW AND VERIFY ALL NOTES, DIMENSIONS, AND ADHERENCE TO APPLICABLE BUILDING CODES PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION. ANY DISCREPANCY OF ERROR IN NOTES, DIMENSIONS, OR ADHERENCE TO APPLICABLE BUILDING CODES SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER'S OFFICE FOR CORRECTION BEFORE COMMENCEMENT OF ANY CONSTRUCTION CORRECTION / REVISIONS. ANY REVISIONS OR CHANGES, NOT RELATED TO THE CORRECTION OF ERRORS THAT ARE MADE AFTER THE FINAL PLANS HAVE BEEN COMPLETED SHALL BE SUBJECT TO ADDITIONAL FEES. IF ANY MODIFICATIONS ARE MADE TO THESE PLANS BY ANY OTHER PARTY OTHER THAN THE DRAFTER'S OFFICE, THE DRAFTER SHALL NOT BE HELD RESPONSIBLE. : A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON SITE FOR THE BUILDING INSPECTOR'S USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY REQUIRED SETBACKS. ALL PLUMBING, ELECTRICAL, AND MECHANICAL ROUGH INS MUST BE COMPLETE, INSPECTED, AND APPROVED BEFORE REQUESTING THE FRAMING INSPECTION (FBC 110.6) : MINIMUM SIZE. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. EXCEPTION: 1. ALL GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SQ FT. MAXIMUM HEIGHT FROM FLOOR : EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44 INCHES MEASURED FROM THE FLOOR. 2. OPERATIONAL CONSTRAINTS : EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS. BARS, GRILLES, GRATES OR SIMILAR DEVICES ARE PERMITTED TO BE PLACED OVER EMERGENCY ESCAPE AND RESCUE OPENINGS PROVIDED THE MINIMUM NET CLEAR OPENING SIZE COMPLIES WITH SECTION 1030.4 AND SUCH DEVICES SHALL BE RELEASABLE OR REMOVABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, TOOL OR FORCE GREATER THAN THAT WHICH IS REQUIRED FOR NORMAL OPERATION OF THE ESCAPE AND RESCUE OPENING. 3. FALL PROTECTION : WHERE THE OPENING OF THE SILL PORTION OF AN OPERABLE WINDOW IS LOCATED MORE THAN 72 INCHES (1829 MM) ABOVE THE FINISHED GRADE OR OTHER SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE AT A HEIGHT NOT LESS THAN 24 INCHES (610 MM) ABOVE THE FINISHED FLOOR SURFACE OF THE ROOM IN WHICH THE WINDOW IS LOCATED. GLAZING BETWEEN THE FLOOR AND A HEIGHT OF 24 INCHES (610 MM) SHALL BE FIXED OR HAVE OPENINGS THROUGH WHICH A 4-INCH (102 MM) DIAMETER SPHERE CANNOT PASS. EXCEPTION: OPENINGS THAT ARE PROVIDED WITH WINDOW GUARDS THAT COMPLY WITH ASTM F 2006 OR F 2090. : PER SECTION R302.5, R302.6, OPENING PROTECTION 1. OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED. OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID OR HONYCOMB CORE STEEL AND NOT LESS THAN 1 3/8", 20 MINUTE RATED, WITH SELF CLOSER. 2. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS THAN 1/2" GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS ABOVE BY NOT LESS THAN 5/8" TYPE "X" GYPSUM BOARD OR EQUIVALENT. : THE MAXIMUM RISER HEIGHT SHALL BE 7.75" AND THE MINIMUM TREAD DEPTH SHALL BE 10". THE TREAD DEPTH SHALL BE MEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF THE ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREADS LEADING EDGE. THE MINIMUM WINDER TREAD DEPTH AT THE WALK LINE SHALL BE 10", AND THE MINIMUM WINDER TREAD DEPTH SHALL BE 6". NOSING SHALL NOT BE LESS THAN 3/4" BUT NOT MORE THAN 1 1/4". A NOSING SHALL NOT BE REQUIRED WHERE THE TREAD DEPTH IS 11". : HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHTS OF 4 OR MORE RISERS. : HANDRAIL HEIGHT, MEASURED ABOVE STAIR TREAD NOSINGS, OR FINISH SURFACE OF RAMP SLOPE SHALL BE UNIFORM, NOT LESS THAN 34" AND NOT MORE THAN 38". HANDRAILS WITH A CIRCULAR CROSS-SECTION SHALL HAVE AN OUTSIDE DIAMETER OF AT LEAST 1.25" AND NOT GREATER THAN 2" OR SHALL PROVIDE EQUIVALENT GRASPABILITY. IF THE HANDRAIL IS NOT CIRCULAR, IT SHALL HAVE A PERIMETER DIMENSION OF AT LEAST 4" AND NOT GREATER THAN 6.25" WITH A MAXIMUM CROSS-SECTION DIMENSION OF 2.25". EDGES SHALL HAVE A MINIMUM RADIUS OF 0.01". HANDRAIL-GRIPPING SURFACES SHALL BE CONTINUOUS, WITHOUT INTERRUPTION BY NEWEL POSTS OR OTHER OBSTRUCTIONS. EXCEPTIONS: 1.HANDRAILS WITHIN DWELLING UNITS ARE PERMITTED TO BE INTERRUPTED BY A NEWEL POST AT A STAIR OR RAMP LANDING. 2. WITHIN A DWELLING UNIT, THE USE OF A VOLUTE, TURNOUT OR STARTING EASING IS ALLOWED ON THE LOWEST TREAD. 3. HANDRAIL BRACKETS OR BALUSTERS ATTACHED TO THE BOTTOM SURFACE OF THE HANDRAIL SHALL NOT BE CONSIDERED OBSTRUCTIONS TO GRASPABILITY, PROVIDED THAT THE FOLLOWING CONDITIONS ARE MET: 3.1. THEY DO NOT PROJECT HORIZ BEYOND THE SIDES OF THE HANDRAIL WITHIN 1½" OF THE BOTTOM OF THE HANDRAIL AND PROVIDED THAT, FOR EACH 1/2" OF ADDITIONAL HANDRAIL PERIMETER DIMENSION ABOVE 4", THE VERTICAL CLEARANCE DIMENSION OF 1½" CAN BE REDUCED BY 1/8". 3.2. THEY HAVE EDGES WITH A RADIUS OF NOT LESS THAN .01". 3.3. THEY OBSTRUCT NOT IN EXCESS OF 20 PERCENT OF THE HANDRAIL LENGTH. : CLEAR SPACE BETWEEN A HANDRAIL AND A WALL OR OTHER SURFACE SHALL BE A MINIMUM OF 1.5". A HANDRAIL AND A WALL OR OTHER SURFACE ADJACENT TO THE HANDRAIL SHALL BE FREE OF ANY SHARP OR ABRASIVE ELEMENTS. : SHALL BE LOCATED ALONG OPEN-SIDED WALKING SURFACES, PLATFORMS, STAIRWAYS, RAMPS AND LANDINGS THAT ARE LOCATED MORE THAN 30" MEASURED VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT WITHIN 36" HORIZONTALLY TO THE EDGE OF THE OPEN SIDE. INSECT SCREENING SHALL NOT BE CONSIDERED AS A GUARD. : REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW THE PASSAGE OF A 4" SPHERE. : PORCHES AND DECKS WHICH ARE ENCLOSED WITH INSECT SCREENING SHALL BE PROVIDED WITH GUARDS WHERE THE WALKING SURFACE IS LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW. : FIREBLOCKING SHALL BE PROVIDED TO CUT OFF ALL VERTICAL AND HORIZONTAL CONCEALED DRAFT OPENINGS. : 1. GLAZING IN DOORS : GLAZING IN ALL FIXED AND OPERABLE PANELS OF SWINGING, SLIDING, AND BIFOLD DOORS SHALL BE CONSIDERED A HAZARDOUS LOCATION. EXCEPTIONS: 1. DECORATIVE GLAZING 2. WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE DOOR AND THE GLAZING. 3. GLAZING IN WALLS ON THE LATCH SIDE OF AND PERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSED POSITION. 4. WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET OR LESS IN DEPTH. GLAZING IN THIS APPLICATION SHALL COMPLY WITH SECTION R308.4.3. 5. GLAZING THAT IS ADJACENT TO THE FIXED PANEL OF PATIO DOORS. 2. GLAZING IN WINDOWS : GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING CONDITIONS: 1. EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET. 2. BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. 3. TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. 4. ONE OR MORE WALKING SURFACES WITHIN 36 INCHES (914 MM) HORIZONTALLY OF THE GLAZING. 3. GLAZING AND WET SURFACES : GLAZING IN WALLS, ENCLOSURES OR FENCES CONTAINING OR FACING SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANY WALKING SURFACE SHALL BE CONSIDERED A HAZARDOUS LOCATION. THIS SHALL APPLY TO SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING. EXCEPTION: GLAZING THAT IS MORE THAN 60" (1,524 mm), MEASURED HORIZONTALLY AND IN A STRAIGHT LINE, FROM THE WATER’S EDGE OF A BATHTUB, HOT TUB, SPA, WHIRLPOOL, OR SWIMMING POOL OR FROM THE EDGE OF A SHOWER, SAUNA, OR STEAM ROOM. 4. GLAZING ADJACENT TO THE BOTTOM OF A STAIR LANDING : GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A STAIRWAY WHERE THE GLAZING IS LESS THAN 36" ABOVE THE LANDING AND WITHIN 60" HORIZONTALLY OF THE BOTTOM TREAD SHALL BE CONSIDERED A HAZARDOUS LOCATION. : IN COMBUSTABLE CONSTRUCTION WHERE THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET. DRAFTSOPPING SHALL DIVIDE THE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR MEMBRANE ABOVE AND A CEILING MEMBRANE BELOW, DRAFTSTOPPING SHALL BE PROVIDED IN FLOOR/CEILING ASSEMBLIES UNDER THE FOLLOWING CIRCUMSTANCES: 1. CEILING IS SUSPENDED. 2. FLOOR FRAMING IS CONSTRUCTED OF TRUSS-TYP OPEN-WEB PERFORATED MEMBERS. 1. MATERIALS : DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN 1/2" GYPSUM BOARD, 3/8" WOOD STRUCTURAL PANELS OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED. DRAFTSTOPPING SHALL BE INSTALLED PARALLELL TO THE FLOOR FRAMING MEMBERS UNLESS OTHERWISE APPROVED BY THE BUILDING OFFICIAL. : A 6-MIL POLYETHYLENE OR APPROVED VAPOR RETARDER WITH JOINTS LAPPED NOT LESS THAN 6 INCHES (152 MM) SHALL BE PLACED BETWEEN THE CONCRETE FLOOR SLAB AND THE BASE COURSE OR THE PREPARED SUBGRADE WHERE NO BASE COURSE EXISTS. EXCEPTIONS 1. GARAGES, UTILITY BUILDINGS AND OTHER UNHEATED ACCESSORY STRUCTURES. 2. FOR UNHEATED STORAGE ROOMS HAVING AN AREA OF LESS THAN 70 SQUARE FEET (6.5 M 2) AND CARPORTS. 3. DRIVEWAYS, WALKS, PATIOS AND OTHER FLATWORK NOT LIKELY TO BE ENCLOSED AND HEATED AT A LATER DATE. 4. WHERE APPROVED BY THE BUILDING OFFICIAL, BASED ON LOCAL SITE CONDITIONS. GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL. THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY. FLAME SPREAD AND SMOKE DEVELOPED INDEXES FOR WALL AND CEILING FINISHES SHALL BE IN ACCORDANCE WITH SECTIONS R302.9.1 THROUGH R302.9.4. FLAME SPREAD AND SMOKE-DEVELOPED INDEX FOR INSULATION SHALL BE IN ACCORDANCE WITH SECTIONS R302.10.1 THROUGH R302.10.5. CS2GENERAL NOTESK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______ FIRST FLOOR PLAN SCALE: 1/4"=1’−0" * A BRK A1.1FIRST FLOOR PLANK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______2’−11"1’−2" MAX. 2x6 STUD WALL SEE PLANS FOR WALL LAYOUT SUBFLOOR BASE CABINET AS PER SHOP DWG. FINISH FLOOR TOP PLATE 1/2" GYP. BD. WD.BASE MOLDING FINISH FLOOR SOLID SURFACE COUNTERTOP. INSTALLER TO PROVIDE APPROPRIATE COUNTERTOP SUPPORT IF REQUIRED 2x WOOD/STEEL FRAMED PARTITION INTERIOR PARTITION w/ INSULATION CMU WALL CMU WALL w/ FURRING & INSULATION NOTE: INTERIOR WALLS ARE DRAWN TO ROUGH DIMENSIONS DOORS LOCATED ADJACENT TO WALL INTERSECTIONS ARE TO BE PLACED 3" MEASURED FROM INTERSECTION TO DOOR JAMB UNLESS DIMENSIONED OR NOTED OTHERWISE. DOORS LOCATED WITHIN A LENGTH OF WALL ARE TO BE CENTERED UNLESS DIMENSIONED OR NOTED OTHERWISE. A B NOTE: TYP. WINDOW HEAD HGT. AT 7’−4" U.N.O. WINDOW HEAD & SILL DETAILS SCALE: 3/4"=1’−0" 2 GARAGE HEAD TRIM DETAIL SCALE: 3/4"=1’−0" 1 REAR ELEVATION SCALE: 1/4"=1’−0" FRONT ELEVATION SCALE: 1/4"=1’−0" NOTE: WRAP THE SAND FINISH TRIM BAND (WHERE SHOWN AROUND WINDOWS & DOORS) INTO THE JAMB, HEAD & SILL OF THE WINDOW & DOORS. PAINT THE BAND, JAMB, HEAD & SILL THE TRIM COLOR. PAINT COLOR SCHEME BODY COLOR TRIM COLOR SAND FINISH MEDIUM TEXTURE / SKIP TROWEL FINISH SURFACE TEXTURE / FINISH KEY STUCCO AND PORTLAND CEMENT PLASTER SHALL BE INSTALLED PER THE CURRENT ASTM C926 & C1063 REQUIREMENTS & PROVISIONS OF THE FLORIDA BUILDING CODE CONTROL JOINTS IN 3−COAT STUCCO SHALL BE USED TO DELINEATE STUCCO AREAS NOT GREATER THAN 144 SQ. FT. OR AT A MAXIMUM DISTANCE OF 18’ BETWEEN JOINTS PER ASTM C1063 (CURRENT EDITION) WEEP SCREED SHALL BE INSTALLED AT STUCCO TRANSITIONS BETWEEN WOOD AND MASONRY AS REQUIRED BY ASTM C1063 (CURRENT EDITION) STUCCO SHALL NOT BE LESS THAN 3 COATS WHEN APPLIED OVER METAL OR WIRE LATH AND SHALL NOT BE LESS THAN 2 COATS WHEN APPLIED OVER MASONRY A2.1FRONT & REAR ELEVATIONSK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______ LEFT ELEVATION SCALE: 1/4"=1’−0" NOTE: WRAP THE SAND FINISH TRIM BAND (WHERE SHOWN AROUND WINDOWS & DOORS) INTO THE JAMB, HEAD & SILL OF THE WINDOW & DOORS. PAINT THE BAND, JAMB, HEAD & SILL THE TRIM COLOR. PAINT COLOR SCHEME BODY COLOR TRIM COLOR SAND FINISH MEDIUM TEXTURE / SKIP TROWEL FINISH SURFACE TEXTURE / FINISH KEY STUCCO AND PORTLAND CEMENT PLASTER SHALL BE INSTALLED PER THE CURRENT ASTM C926 & C1063 REQUIREMENTS & PROVISIONS OF THE FLORIDA BUILDING CODE CONTROL JOINTS IN 3−COAT STUCCO SHALL BE USED TO DELINEATE STUCCO AREAS NOT GREATER THAN 144 SQ. FT. OR AT A MAXIMUM DISTANCE OF 18’ BETWEEN JOINTS PER ASTM C1063 (CURRENT EDITION) WEEP SCREED SHALL BE INSTALLED AT STUCCO TRANSITIONS BETWEEN WOOD AND MASONRY AS REQUIRED BY ASTM C1063 (CURRENT EDITION) STUCCO SHALL NOT BE LESS THAN 3 COATS WHEN APPLIED OVER METAL OR WIRE LATH AND SHALL NOT BE LESS THAN 2 COATS WHEN APPLIED OVER MASONRY RIGHT ELEVATION SCALE: 1/4"=1’−0" A2.2SIDE ELEVATIONSK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______ 5:12 5:125:121’−0"1’−0"1’−0"1’−0"1’−0"1’−0"1’−0"1’−0"5:125:125:12 5:122’−0"4’−0"ROOF VENTS TYP. R806.2:THE MINIMUM NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE VENTED SPACE. EXCEPTION: THE MINIMUM NET FREE VENTILATION AREA SHALL BE 1/300 OF THE VENTED SPACE PROVIDED NOT LESS THAN 40 PERCENT AND NOT MORE THAN 50 PERCENT OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. ATTIC VENTILATION − AT FIRST FLOOR SQ. FT. ATTIC AREA NET FREE AREA SOFFIT VENTING NET FREE AREA UPPER ROOF VENTING VENTS REQUIRED 48" TAMCO OFF−RIDGE VENT (138 SI NET FREE) − NOTE: LOCATE RIDGE VENTS 2'-0" OFF ALL HIPS RIDGES OR VALLEYS, MIN., TYP. TOTAL VENTING REQUIRED ROOF PLAN SCALE: 1/4"=1’−0" UNDERLAYMENT APPLICATIONS SHALL BE INSTALLED IN ACCORDANCE WITH SECTION R905, TABLE R905.1.1 FOR ASPHALT SHINGLES REFERENCE TO SECTION R905.2 FOR TILE ROOFING REFERENCE TO SECTION R905.3 A3.1ROOF PLANK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______1/2/20REVISE ROOF VENTING FIN. FLR.8’−8"T.O. M. T.O. WDW 7’−4"12 5 PRE−ENGINEERED ROOF TRUSSES SEE FRAMING SHEET FOR DETL’S R−30 INSULATION 12 5 ROOF SHINGLES PER COMMUNITY SPECS. (TYP.) A-5.1 2 A-5.1 2 CONCRETE FOOTING SEE STRUCTURAL PLANS R−4.1 INSULATION R−4.1 INSULATION CONCRETE FOOTING SEE STRUCTURAL PLANS FIN. FLR.8’−8"T.O. M. T.O. WDW 7’−4"A-5.1 1 A-5.1 1 12 5 PRE−ENGINEERED ROOF TRUSSES SEE FRAMING SHEET FOR DETL’S ROOF SHINGLES PER COMMUNITY SPECS. (TYP.) 12 5 R−4.1 INSULATION R−30 INSULATION R−11 INSULATION K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______A5.1BUILDING SECTIONSBUILDING SECTION SCALE: 1/4"=1’−0" BUILDING SECTION SCALE: 1/4"=1’−0"1/2/20ADD INSULATION VALUES4/15/20PLAN UPDATES SEE ROOF PLAN PROVIDE 2X4 FRAMED ENCLOSURE FOR ELECTRICAL PANEL, FINISH W/ 1 2" GYPSUM BOARD ELECTRICAL PANEL CONCRETE CURB REFER TO PLANS ELECTRICAL PANEL CONCRETE CURB REFER TO PLANS GYPSUM BOARD GYPSUM BOARD GARAGE ELECTRICAL PANEL IS TO BE INSTALLED ACCORDING TO ALL APPLICABLE LOCAL, STATE AND NATIONAL CODES. VERIFY PANEL DIMENSIONS PRIOR TO CONSTRUCTION. CONCRETE SLAB ON GRADE AT GARAGE FLOOR ATTIC OR SECOND FLOOR LIVING SPACE REFER TO PLANS 1 2" GYPSUM BOARD NICHE FOR ELECTRICAL PANEL & WIRING 2’−4"6’−2"2’−4"3’−2"6’−2"8"PER PLAN3"1’−0"3" 1’−6" 3 1/2" EXTERIOR CMU BLOCK WALL EXTERIOR CMU BLOCK WALL STUCCO FINISH ELECTRIC METER LOCATION − SEE PLANS. VERIFY INSTALLATION IN FIELD 3’−2"8"PER PLANT.O. M GRADE ATTIC OR SECOND FLOOR LIVING SPACE REFER TO PLANS 3/4"4"K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______A5.2TYPICAL WALL SECTIONS1/2/20ADD GABLE DETAIL FOLD FOLD @ 45° FOLD @ 77° WATERTIGHT SEAL. FOLD. BOTTOM FLANGE 7 8" THICK, 3 COAT CEMENT PLASTER WRAP LAYERS OF BUILDING WRAP OVER NAILING FLANGE, STOP WRB 1−1/2" ABOVE SHINGLES 5X5 WALL FLASHING KICK−OUT FLASHING (SEE DTL. BELOW) SHINGLE ROOFING FELT UNDERLAYMENT FASCIA WRAP DRIP EDGE: OVERLAP 3", EXTEND BELOW SHEATHING, MECH. FASTEN 4" O.C. MAX. 60 MIN. GRADE D PAPER BACKED LATH BARRICADE PLUS WRB (OR APPROVED EQUAL)6"6"6"EXTERIOR CMU WALL 1) PROTECTO WRAP LWM200 OR SIMILAR ON WINDOW SILL, JAMBS AND HEAD. APPLY AROUND CORNER AND EXTEND 6" ALL AROUND THE EDGES OF THE WALL 2) SET P.T. WOOD BUCK OVER CMU WATERPROOFING IN URETHANE SEALANT. FASTEN PER PRODUCT APPROVALS. 3) APPLY LIQUID WATERPROOFING MEMBRANE OVER THE TOP AND EXTERIOR FACE OF BUCK AND SILL 4) INSTALL WINDOW OR DOOR. FASTEN PER PRODUCT APPROVALS AND SEAL WINDOW OR DOOR FRAME TO P.T. WOOD BUCK AND MASONRY CMU OPENING WATERPROOFING SCALE: N.T.S. SEAL EDGE OF P.T. WOOD BUCK TO MASONRY PRECAST SILL WOOD SHEATHING 60 MIN. GRADE D PAPER BACKED LATH OVER BARRICADE PLUS WRB (OR APPROVED EQUAL) 7 8" THICK, 3 COAT CEMENT PLASTER METAL LATH LAP WRB & TAPE OVER 5X5 "L" TYPE CONTINUOUS GALV. METAL FLASHING (NAIL TO ROOF DECK, NOT WALL SHEATHING) CAP SHINGLE − DO NOT NAIL, INSTALL WITH ROOF CEMENT SHINGLE ROOFING ROOF CEMENT ICE AND WATER SHIELD 15" VERTICAL AND 15" DOWN ROOF K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______WP1WATERPROOFING DETAILS4/15/20PLAN UPDATES 3#10 , 1#6G 1 12" C 150 A MLO PANEL 42 CIRCUITS N1 150 A METER COMBO 120/240V 1ph. N3R 22K AIC 150A/2P 30A/2P A.C. COMPRESSOR 3#10, 3/4" C #4 GROUND WIRE BLDG STEEL 2 GROUND ROD 5 8"x8’ GALV. 2" PVC STUB DOWN FOR FLORIDA POWER & LIGHT WP/GFI LELIA LOAD CALCULATIONS PANEL "A" DESCRIPTION LOAD KVA GENERAL LTG. 3Wx1917 S.F. 5751 SMALL APPLIANCE SMALL APPLIANCE REFRIGERATOR DISHWASHER DISPOSAL MICROWAVE RANGE WATER HEATER DRYER WASHER LAUNDRY EXTERIOR GFI IRRIGATION GDO TOTAL KVA AHU #1 HEAT FIRST 10KW BALANCE @ 40% AC LOAD TOTAL LOAD KVA/240V 1500 1500 1200 2400 850 1200 8000 4500 5000 1500 1500 1500 800 900 38101 10000 KWx.65 6500 10000 11240 6500 27740 116 AMPS WIRE POLE TRIP DESCRIPTION CKT WIREPOLETRIPDESCRIPTIONCKT 1 5 3 7 9 11 13 15 17 19 21 23 25 27 29 31 35 33 37 39 2 6 4 8 10 12 16 14 18 20 22 26 24 28 30 32 36 34 38 40 #10 #6 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #6 #10 #10 #12 #14 #14 #14 #14 #14 #14 2P 2P 1P 1P 1P 1P 1P 1P 1P 1P 1P 1P 1P 30A 60A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 2P50A 2P 2P 25A 30A 20A 1P 1P 1P 1P 1P 1P 1P 15A 15A 15A 15A 15A 15A SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE AIR COMPRESSOR AIR HANDLER DISHWASHER (AF/GFI) DISPOSAL (AF/GFI) WASHER (AF/GFI) REFRIGERATOR (AF) SMALL APPLIANCE (AF/GFI) SMALL APPLIANCE (AF/GFI) BATH (GFI) GARAGE DR. OPENER (GFI) GARAGE (GFCI) SPRINKLER SOLENOID EXTERIOR (GFI) RANGE WATER HEATER DRYER MICROWAVE (AF) GENERAL LTG. (AF) GENERAL LTG. (AF) GENERAL LTG. (AF) GENERAL LTG. (AF) GENERAL LTG. (AF) GENERAL LTG. (AF)10’−0"P.C. ATTIC LIGHT 2’−0"ELECTRICAL PANEL ON 2X4 WALL M P.B. FOR CHIMES WET BAR A/C DISCONNECT 33ADD BLOCKING AS REQUIRED SD ADD BLOCKING AS REQUIRED SD ADD BLOCKING AS REQUIRED 33DISCONNECT 3 33−BULB FIXTURE 3 ADD BLOCKING AS REQUIRED VP 3−BULB FIXTURE ADD BLOCKING AS REQUIRED RANGE333SD3 ADD BLOCKING AS REQUIRED 3 PREWIRE FOR GARAGE DOOR OPENER 3 ADD BLOCKING AS REQUIRED D/WUNDER−SINK SWITCH FOR DISPOSAL CL IRRIGATION TIMER LOCATION VARIES PER MAIN WATER SERVICE CONNECTION 33 FIELD VERIFY METER CAT 5 CAT 5 STRUCTURED WIRE PANEL (SWP) VERIFY LOCATION IN FIELD W/D SPACE VP SD CAT 5 LOCATE MICRO. OUTLET IN UPPER CABS. WH DISCONNECT 3 3’−0"60" A.F.F. WITH STRUCTURAL BACKING FOR TV D W 4’−0"5’−10" ADD BLOCKING AS REQUIRED FIRST FLOOR ELECTRICAL PLAN SCALE: 1/4"=1’−0"E1.1FIRST FLOORELECTRICAL PLANK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______LOAD CALCULATIONS SCALE: N.T.S. PANEL SCHEDULE SCALE: N.T.S. ELECT. RISER DIAGRAM SCALE: N.T.S. WET BAR 17’−4"19’−10"21’−11"18’−812"16’−212"20’−412"2’−33 4" 10’−10"6’−3"8’−912"11’−8"8’−1112"11’−9"11’−11 1 2"3’−712"15’−91 2" 11’−10 1 2"RANGE7’−21 2"13’−10"6’−01 2" 9’−51 2"6’−3"W/D SPACE HB.LOCATION VARIES PER MAIN WATER SERVICE CONNECTION 7’−61 2" 12’−9" D W CONDENSATE LINE (V.I.F.)K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______SLAB PENETRATION PLAN SCALE: 1/4"=1’−0" P1.1SLAB PENETRATION PLANPLUMBING RISER DIAGRAM SCALE: N.T.S.