HomeMy WebLinkAboutTrussA=LIFE SAFETY WARNING This symbol identifies Life Safety Warnings that should be read given special attention by all persons installing trusses. 5PAGING NOTE i ALL TRUSSES ARE TO BE SET AT 2.-0: ON CENTER EXCEPT AS NOTED ASTENED TOGETHER PER ENGINEERIN BEFORE SETTING. REFER TO ENGINEERING DRAWING TO DETERMINE A IF MULTIPLE PLY. A DON'T LIFT TRUSSES WITH SPANS LONGER THAN 30' BY THE PEAK. CONSULT BCSI 30' Span or less - 30' to 60' Span 0 degrees Spree er Bar or less �.-_ 1./2 .� i a9-.—APProx 2/3 to Tag Line span approx. e /2 of span REFER TO BCSI REFER TO BCSI Truss must be set this way if crane. used. Truss must be set this way if crone used. Truss is an example, your truss may not match. This is an example, truss may not match. . Insist crane operator sets truss this way. Insist crone operator sets truss this way. I I t �i r U REPRESENTS A HANGER SEAT r U REPRESENTS A HANGER SEAT PLATES BY CHAMBERS INDICATES LOAD BEARING WALL REQUIRED BY TRUSSES SUPPLIED BY BUILDER AT A HEIGHT OF 8'-1" ABOVE FINISHED FLOOR 12 4.00 r— to M upset=1/4" heel=315/16" lip PLUMB CUT END 2 x 4 Top Chord WALL HEIGHT 8'-1" TYPICAL END DETAIL lip Y i L. ;ry 12 4.00 F--- 7! 2.00 �8 1r Cl) 12 upset=1/4" heel=315/16" PLUMB CUT END 1' 2 x 4 Top Chord WALL HEIGHT 8'-1" END DETAIL: A j l The Architect's or Architect's re shop drawingl"'esentative's ^/ P'1( �[i ��1f is "double check"ao the a, O1T a. II' A ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 17' 23' IN �NGTH The eontrac#or shall the responsible for eheektng fieitl measurements antl other construction criteria. Architect's ' Do not stand on trusses until they are braced r;er BCSI & properly nailed to straps & hangers ow'p;��U9Sg aeneralraofShape, structure from in and and loading cn gravity and uplift loads and thajr re tive locations. . -- — — APprovad B Date: _. ' Braden R o._� 34- GARAGE LEFT 34' 20' 14' A.LA. P.A. FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED The legal description of the property where the trusses will be Installed is: .The undersigned acknowledges and agrees; 11 Trusses will be made in strict accordance with this truss placement diagram layout, which Is the sole authority for detennlning.successful fabrication of the trusses. 2. NI dimensions In this layout have been vertfied by the undersigned, 3. Unless wniten notice Is provided by corthied mall to Chambers Truss vdthin ten (10) days' of delivery the undersigned agrees that no backcharges will be allowed. In the event such vrtfhen notice Ia furnished Chambers Trues shall have three (3) bustnose days In which I. bagln rapelrs required, or to substitute other trusses, at Chambers opd n. 4, I Tha undarelgn d acknowledges receipt Of 'SCSI 1.03" summary sheet by TPI & WTCA, 5. Dallvary Is to ob site. It is the buyer'e'reeponeiblllty to make the job site suitable for delivery. Chambers Truss has the sole authority to determine, the suitability of the job she or a portion of the job site for delivery. Chambers Truss will be responsible for dump delivery only. The buyer Is responsible for additional delivery expenses If Chambers Truss has to redeliver bemuse job she Is not prepared for delivery or buyer Is not prepared for delivery of trusses, Buyer Is responsible to Chambers Truss for towing costs due to site cundltions. 5. Prim as shown In paragraph 7 below Is subject to change If any changes are, made M this.ley6a A $50 per hour fee for revisions may be charged by Chambers Truss, .7: This Is a PURCHASE ORDER to Chambers,Twss of the sum agreed to, or If n'; agreement a reasonable price. Invoice will be made on delivery and paid whhln terms of n J. on delivery. Invoice may, be made at scheduled date of. delivery If buyer cannot accept' delivery of fabricated trusses. The undersigned agrees to pay Chambom.Tfuss reasonable ahomey's fee for collections In event of payment not timely made. 1.112 % per month seryjce charge will be added for all sums not paid within terms. 5, signature or Initials anywhere on this sheet constitutes agreement to all terms herein, 9, in consideration of Chambers Truss extending credit for this materiel the undersigned unconditionally guarantees payment when due of any and all Indebtedness owed to Chambers Truss by any entity racelvingmaterial and the undersigned agrees to pay such Indebtedness Including attorneys fees, If default In payment for material be made by the recipient, - 1. '10. In the event of any litigation concerning this agreement, the hems furnished hereunder or payments referred to herein, the, parties agree that the sole venue for any such action will be saint Wale County, Florida. 11. Design responslbilides are per "National Standard And Recommended Guidelines On Responsibilities For Construction Using Metal Plate Connected Wood Trusses ANSIyTPIM?CA 4 - 2002" DATED SIGNED FOR TITLE_ _ Aspreader bar may be lequifed per"BCS11-03" lo prevent injtaydamage. Multiple ply trusses must be festaned together per engineering before they are set failure to do so can result In roof collapse. Temporary and permanent bracing are required and can save life and property and Is the responsibility of the truss erector. Study the contents of the Information packet Included on delivery before setting trusses, Tamses mustbe setard brac od perdeslgn to pretont iILUY P- damage, s Trusses must be set plumb and square Do tiotset bunks or stack of plywood, roofing material or any ' Other LdY .centrated loads on trusses, this can cause collapse. DO NOT SET TRUSSES USING THIS LAYOUT ` USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES I CHAMBERS TRUSS INC 3105 Oleander Avenue Fort'Piertdej Florida 34982.6423 800-551-5932 Fort Pierce 772465-2012 Fax 772-465.8711 Vero Beach 772-569-2012 Stuart 772-286-3302 ' 92.0 /93.2 MITEK 4. DESIGN CRITERIA - - County SAINT LUCIE Building Department SAINT LUCIE COUNTY Wind Design Criteria ASCE 7-2010 i Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-1 d Roofing Material Shingle or Shake N I Loading in PSF Roof R.D.L. N M Top Chord Live 20 `) Top Chord Dead 7 4.2 �? Bottom Chord Live 10 Non -Concurrent 4h m Bottom Chord Dead 10 3 c<j l I TOTAL Load 37 7.2 ra o Duration Factor 1.25 R Wind Speed 165mph to�+ Top Chord C.B. Sheeting by builder. I Bottom Chord C.B. Sheeting by builder. 0 �,) Highest Mean Height 14'-0a Building Type ENCLOSED Building Category II:Non Restrictive Exposure Category C Barrier Island No Conforms to FBC 2017 R.D.L.=Restrainin Dead Load C.B: Continuous Bracin l Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the R, ild4no Desi ner and/or En ineer of Record. Chambers Truss Inc. Drawing Name: M11323 LIJ Scale: 1 /4 = 1' 72 total trusses, 13 different trusses. MI 4: SAE ACAD: SAE Reviewed By: (J) Date:04/24/12 Revised:02/21/18 FOR Revised: 3/05/2020 s's" 3' 4" s' a" -_ 1-10° MNNE BUILDING CORP. '34' - -- - PPSION: 1 G A i DE �hITIE AGE RIGHT S ra LtY81V J30I VVER INITIALS EACH PAGE t 13 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT am"T1323 i6 9 it 37b gf�U i MM MiTek' ti3 RE: M11323 MITek USA, Inc. M11323 6904 Parke East Blvd. Tampa, FL 33610-4115 Site Information: Customer: WYNNNE DEVELOPEMENT CORP Project Name: M11323 Lot/Block: Model: CARLTON Address: N/A Subdivision: City: PORT ST LUCIE State: FL General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 13 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# 1 T19884596 Truss Name A Date 7/31/2020 FILE 2 T19884597 A5 7/31/2020 3 T19884598 A6 7/31/2020 4 T19884599 A7 7/31/2020 5 T19884600 A8 7/31/2020 6 T19884601 A9 7/31/2020 7 T19884602 GRA 7/31/2020 8 T19884603 GRB 7/31/2020 9 T19884604 J2 7/31/2020 10 T19884605 J4 7/31/2020 11 T1988460 12 T19884607 J6 J8 .7/31/2020 7/31/2020 1� REVIEWED Ei/ n I E W E® FOR 13 T19884608 KJ8 7/31/2020 CODE COMPLIANCE Si® LUCIE COUNTY BCCC This item has been electronically signed and sealed by Velez, Joaquin using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced above have been prepared by MiTek USA, Inc under my direct supervision ,,`��rtt based on the parameters provided by Chambers Truss. `�� PCLU I N VFW ��� Truss Design Engineer's Name: Velez, Joaquin �� �0 ��G E N 8F F� ����, My license renewal date for the state of Florida is February 28, 2021. Florida COA: 6634 No 68182 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. -33:. STATE OF :�44/' ,, EEC? �% O N A 11111 Joaquin Velez PE No.68182 MITek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 July 31, 2020 1 of 1 Velez, Joaquin Job , I s Truss Type Ply M11323 TA T19884596 M11323 COMMON �Qty 9 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL �1 O 4.00 12 45 = 27 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:27 2020 27-4-3 34-0-0 Scale = 1:57.8 17 '" 15 '" -' 14 12 3x6 — 2x3 II 4x6 3x8 = 3x8 = 4x6 2x3 II 3x6 = 6-7-13 12-4-13 21-7-3 27.4-3 34-0-0 6-7-13 S-9-0 9-2-7 5-g-0 6-7-13 Plate Offsets (X,Y)— [2:0-0-2,Edge), [10:0-0-2,Edge) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) 0.32 14-15 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.58 Vert(CT) -0.61 14-15 >670 240 BCLL 0.0 Rep Stress Incr YES WB 0.65 Horz(CT) 0.12 10 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 163 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-7-12 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-11-7 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 8) Max Uplift 2=-832(LC 10), 10=-832(LC 10) Max Grav 2=1362(LC 1), 10=1362(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3419/2395, 3-5=2771/2031, 5-6=-2770/2152, 6-7=-2770/2152, 7-9=-2771/2031, 9-10=3419/2395 BOT CHORD 2-17=-2132/3213, 15-17=-2132/3213, 14-15=-126912000, 12-14=-2132/3213, 10-12=-2132/3213 WEBS 6-14=-635/983, 7-14=-313/362, 9-14=-689/499, 6-15=-635/983, 5-15=-313/362, 3-15=-689/499 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 13-7-3, Exterior(2)13-7-3 to 204-13, Interior(1) 20-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide This item has been will fit between the bottom chord and any other members, with BCDL = 10.Opsf. electronically Signed and 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except (jt=1b) sealed by Velez, Joaquin, PE 2=832,10=832. using a Digital Signature. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 50 lb down and 47 lb up at Printed copies of this 15-0-0. and 50 lb down and 47 lb up at 19-0-0 on top chord. The design/selection of such connection device(s) is the responsibility of others. document are not considered 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). signed and Sealed and the signature must be verified LOAD CASE(S) Standard on any electronic copies. 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Joaquin Velez PE No.68182 Vert: 1-6=-54, 6-11=-54, 18-21=-20 MiTek USA, Inc. FL Cart 6634 Concentrated Loads (lb) 6904 Parke East Blvd. Tampa FL 33610 Vert: 26=-50(F) 27=-50(F) Date: April 3,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall r building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek- is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/1 Quality Criteria, DSO.89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job, Truss Truss Type Qty Ply M11323 T19884597 M11323 A5 SPECIAL 9 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:28 2020 Page 1 ID:2GIScwwyY5hnGhXVARzUkuyuFUM-3MHjMkAMIKQgXE1 PNJV2mXOxRucedNo4iX50ryzUUjv 1-0-0 7-8-5 1%6.4 17-M 20-4-8 26 4-0 34-0-0 5 0 -0-0 7-8-5 2-9-15 6-5.12 3-4-8 111-8 7-8-0 -0-0 5x8 MT18HS 11 4.00 12 Scale = 1:59.8 1IA 6 13 12 3x12 2.00 12 5x12 = 2x3 II 3x6 = = 26-4-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deb Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.85 Vert(LL) 0.76 14 >539 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -1.18 13-14 >344 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.60 Horz(CT) 0.36 10 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MS Weight: 155 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 1-7-8 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 3-9-12 oc bracing. WEBS 2x4 SP No.3 *Except* WEBS 1 Row at midpt 6-14 6-14: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 8) Max Uplift 2=-803(LC 10), 10=-803(LC 10) Max Grav 2=1312(LC 1), 10=1312(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-5529/3776,3-5=-5164/3538, 5-6=-5209/3667,6-7=-2424/1902, 7-9=-2462/1813, 9-1 0=-3195/221 0 BOT CHORD 2-14=-3466/5266, 13-14=-1305/2115, 12-13=-1948/2995, 10-12=-1948/2995 WEBS 3-14=-355/314, 5-14=-293/354, 6-14=-2175/3326, 6-13=-279/534, 7-13=-2371277, 9-1 3=-786/560, 9-12=01269 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 24-13, Interior(1) 2-4-13 to 13-7-3, Exterior(2) 13-7-3 to 20-6-4, Interior(1) 20-6-4 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=803,10=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria, DSB-69 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job , Truss Truss Type City M11323 T19884598 M11323 A6 SPECIAL 1 �Ply 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:29 2020 Page 1 ID:2GIScwwyY5hnGhXVARzUkuyuFUM-YYr6a48 WeYX90cbw00HJlx7ilyPMm6DxBgyOOzUUju 1-0- 8-11-11 16-0-0 18-0-0 204-8 25-11-15 34-0-0 5-0 -0-0 8-11-11 7-0-5 2-0-0 24-8 5-7-7 8-0-1 -0-0 4.00 12 N't1 3x12 = 2.00 12 10-6-4 LOADING (psq SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017/TPI2014 LUMBER - TOP CHORD 2x4 SP M 30 *Except' 3-5,6-7: 2x4 SP M 31 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 `Except' 5-14: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-169(LC 8) Max Uplift 2=-803(LC 10), 9=-803(LC 10) Max Grav 2=1312(LC 1). 9=1312(LC 1) 6xl0 MT18HS = 5x6 = IL 11 5x6 = 20 II 34-0-0 3x6 = Scale=1:61.9 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TC 0.81 Vert(LL) 0.69 14 >590 360 MT20 244/190 BC 0.93 Vert(CT) -0.9214-17 >443 240 MT18HS 244/190 WB 0.86 Horz(CT) 0.34 9 n/a n/a Matrix -MS Weight: 157 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puffins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-5491/3336, 4-5=-5095/3071, 5-6=-2314/1551, 6-8=-2398/1533, 8-9=-3199/1981 BOT CHORD 2-14=-3040/5224,13-14=-1195/2361,12-13=-1123/2199,11-12=-1731/3001, 9-11=-1731/3001 WEBS 4-14=492/513, 5-14=1707/2959, 5-13=-405/196, 6-13=-179/522, 8-12=-893/660, 8-11=0/303 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=1411; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 24-13 to 31-7-3, Extedor(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0. psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at Joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=803, 9=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11II-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MOWis always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke Past Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job , Truss Truss Type Qty Ply M11323 T19884599 M11323 A7 SPECIAL 1 1 Job Reference o tional (.umbers truss, Inc., Fort Pierce, FL 8-10-10 4_nn 3x12 = 2.00 12 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:30 2020 20-0-0 5-11-15 5x8 = Sx6 = IV 9 5x12 = 2x3 II 3x6 = Scale=1:60.8 IA l�l 6 LOADING (psf) SPACING- 2-0-0 CSI. , DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.83 Vert(LL) 0.66 11 >616 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -1.10 10-11 >369 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.95 Horz(CT) 0.34 7 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 147 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-0-2 oc bracing. WEBS 2x4 SP No.3 *Except* 4-11: 2x4 SP M 30 REACTIONS. (size) 2=0-8-0, 7=0-8-0 Max Horz 2=-149(LC 8) Max Uplift 2=-803(LC 10), 7=-803(LC 10) Max Grav 2=1312(LC 1), 7=1312(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -Ail forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5484/3370, 3-4=-5116/3126, 4-5=2229/1544, 5-6=-2448/1599, 6-7=-3169/1993 BOT CHORD 2-11=3071/5219, 10-11=-1590/2874, 9-1 0=-1 73B/2968, 7-9=-1738/2968 WEBS 3-11=-419/443, 4-11 =-1 466/2647, 4-10=-812/448, 5-10=-205/487, 6-10=-785/575, 6-9=0/272 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 24-13, Interior(1) 24-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/rPl 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=803, 7=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safely/nformadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job . Truss Truss Type City Ply T19884600 M11323 A8 SPECIAL 1 1 �1`411323 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:31 2020 Page 1 1 -0-ID:WSJgpGwa I Pp eu r6hk9UjG5yuFUL-Uxzs_mCE2FoFOiI2R2I0AOTj6eKgj EWO UJ2S HzU Ujs 8-8.4 2 -0 0 584 204-8 22-0-0 48-2 34-_5-0- 3-8 1-2-8-12 9-3-4 -0-0-4 4-87-8 Scale = 1:60.6 5x6 = 4.00 12 3x4 = 2x3 II 5x8 = 21 5 6 22 7 12 11 5x12 = 3x4 = 45 = 3x12 = 2.00 12 10-6-4 20.4-8 22-0-0 34-0-0 10-6-4 9-10-4 1 1-7-8 12-0-0 Plate Offsets (X,Y)— [2:0-1-15,Edge] [7:0-5-8,0-2-81 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.78 Vert(LL) 0.65 12-13 >624 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -1.08 12-13 >379 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.69 Horz(CT) 0.33 9 n/a n/a BCDL 10.0 Code FBC2017lrP12014 Matrix -MS Weight: 154 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 3-11-11 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-129(LC 8) Max Uplift 2=-803(LC 10), 9=-803(LC 10) Max Grav 2=1312(LC 1),9=1312(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5488/3444, 3-4=-5117/3183, 4-5=-3911/2497, 5-6=-2576/1770, 6-7=-2586/1779, 7-8=-2663/1762, 8-9=-3021/1971 BOT CHORD 2-13=-3143/5224, 12-13=-1956/3292, 11-12=-1369/2481, 9-11=-1705/2827 WEBS 3-13=-396/420, 4-13=-1028/1721, 5-13=-300/797, 5-12=-894/601, 6-12=-2651263, 7-12=-294/391, 7-11=-374/691, 8-11=-535/502 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 24-13, Interior(1) 2.4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. . 7) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=803, 9=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall but building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Addillonal temporary and permanent bracing IV14 8 k° is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the �qi1 fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Ply M11323 � �Qty T19884601 M11323 A9 HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:32 2020 Page 1 ID:_etC1 cxC3ixVV?huls?ypJyuFUK-y7XEC6DspZw6OsKAc9Z_xNZ18W4CZ7Mfd83c?jzUUjr 1-0-0 6-7-15 10-0-0 15-2-14 20-4-0 24-0-0 27-4-1 34-0-0 5-0- -0-0 6-7-15 3I 5-2-14 5-1-2 3-8-0 3 4-1 6-7-15 0-0 4.00 12 3x5 = 4x4 = 3x4 = 2x3 II 48 = 4 24 525 26 6 27 7 15 14 13 12 11 3x8 = 3x6 = 6x8 = 3x6 = 3x4 = Scale = 1:58.6 3x5 IT 0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.35 Vert(LL) -0.18 11-21 >917 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.54 Vert(CT) -0.38 11-21 >432 240 BCLL 0.0 Rep Stress Incr YES WB 0.89 Horz(CT) 0.02 13 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix -MS Weight: 156 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-11-9 cc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 cc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0, 13=0-8-0 Max Horz 2=109(LC 9) Max Uplift 2=-430(LC 10), 9=-249(LC 10), 13=-928(LC 10) Max Grav 2=685(LC 19), 9=386(LC 20), 13=1616(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1275/1025, 3A=-913/708, 4-5=-829/705, 5-6=-565/807, 6-7=-565/807, 7-8=-104/278, 8-9=-341/235 BOT CHORD 2-15=-836/1187, 13-15=-34/309, 11-13=-256/348, 9-11 =-1 24/304 WEBS 3-15=-425/501, 5-15=-444/665,5-13=-1215/1079, 6-13=-264/300, 7-11=-255/396, 8-11=-461/521, 7-13=-837/703 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 5-2-5, Exterior(2) 5-2-5 to 14-9-11, Interjor(1) 14-9-11 to 19-2-5, Exterior(2) 19-2-5 to 28-9-11, Interior(1) 28-9-11 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=430, 9=249, 13=928. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall m A♦ building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing IV iiTe k• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/f Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldod, MD 20601 Tampa, FL 36610 Job - Truss Truss Type Qty Ply M11323 T19884602 M11323 GRA HIP 1 1 Job Reference (optional) unamoers i russ, inc., ron tierce, rL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:33 2020 Page 1 I D:_etCt cxC3ixVV?huls?ypJyuFUK-QK4cPSEUat2zdOvM9s4DTb5n5vPvlY6proo9XAzUUjq 1-0-0 8-0-0 11-1-1 17-0-0 18-6-0 22-2-2 26-0-0 34-0-0 5-0- -0-0 8-0-0 3-1-1 5-10-15 1-6-0 3 8-2 3-9-14 8-0-0 -0-0 THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. 4x4 = Scale=1:60.6 3x5 —_ 3x6 II 3x6 = 6x8 = 3x6 = 6x8 = 4x4 = 6x8 = TRUSS DESIGNED FOR WIND LOADS IN THE PLANE OF THE TRUSS ONLY. FOR STUDS EXPOSED TO WIND (NORMAL TO THE FACE), SEE STANDARD INDUSTRY GABLE END DETAILS AS APPLICABLE, OR CONSULT QUALIFIED BUILDING DESIGNER AS PER ANSI/TPI 1. 8-0-0 11-1-1 18.6-0 26-M 34-0-0 8-0-0 3-1-1 7-4-15 7-6-0 8-0-0 Plate Offsets (X,Y)— [2:0-2-2,Edge], [3:0-3-8,Edge] [21:0-3-8 Edge] [24:0-3-8 0-3-01 [27:0-3-8 0-3-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.91 Vert(LL) 0.20 24-35 >914 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.57 Vert(CT) -0.24 29-32 >552 240 BCLL 0.0 Rep Stress Incr NO WB 0.98 Horz(CT) 0.02 22 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix -MS Weight: 194 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 4-2-5 oc purlins. BOT CHORD 2x4 SP M 30 Except: WEBS 2x4 SP No.3 1 Row at midpt 8-21 BOT CHORD Rigid ceiling directly applied or 6-0-0 cc bracing. JOINTS 1 Brace at Jt(s): 7, 8, 19, 17, 14 REACTIONS. All bearings 0-8-0. (lb) - Max Horz 2=-179(LC 6) Max Uplift All uplift 100lb or less atjoint(s) except 2=-351(LC 8), 27=-1168(LC 8), 26=-1495(LC 8), 22=-625(LC 8) Max Grav All reactions 250 lb or less atjoint(s) except 2=487(LC 17), 27=2232(LC 13), 26=2929(LC 14), 22=984(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-621/387, 3-5=-304/838, 5-7=-588/1209, 7-8=-588/1209, 8-12=-588/1209, 12-13=-588/1209, 13-15=-588/1209, 15-16=-588/1209, 16-18=-588/1209, 18-20=-2230/1280,20-21=-2230/1280,21-22=-2271/1263,6-9=-126/305,9-11=-106/363, 11-14=-193/412, 14-17=-94/271, 19-21=-143/272 BOT CHORD 2-29=-247/677, 27-29=-189/540, 26-27=-779/446, 24-26=-411/653, 22-24=-1083/2108 WEBS 3-29=-500/1176, 3-27=-1766/911, 5-27=-748/622, 5-26=-546/351, 13-26=-946/617, 18-26=-2412/1474, 18-24=-846/1780, 21-24=-35/351, 4-5=-608/514,19-20=-335/305, 14-15=-556/407, 11-12=-254/54 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. This item has been II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 electronically signed and 3) Provide adequate drainage to prevent water ponding. Sealed by Velez, Joaquin, PE 4) All plates are 2x3 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. using a Digital Signature. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Printed copies of this will fit between the bottom chord and any other members. document are not Considered 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 351 lb uplift at joint 2, 1168 lb uplift at signed and sealed and the joint 27, 1495 lb uplift at joint 26 and 625 lb uplift at joint 22. 8) Girder carries hip end with 8-0-0 end setback. signature nature must be verified 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. on any electronic Copies. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at Joaquin Velez PE Nc.68182 26-0-0, and 967 Ib down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the MiTek USA, Inc. FL Cart 6634 responsibility of others. 6904 Parke East Blvd. Tampa FL 33610 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). Date: April 3.2020 andard ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5I79Y2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall .r building design. Bracing indicated is to prevent buckling of individual buss web and/or chord members only. Additional temporary and permanent bracing MiTek* always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job • Truss Truss Type Qty Ply T19884602 M11323 GRA HIP 1 1 �M11323 Job Reference o tional Lmambers truss, Inc., I -on Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:33 2020 Page 2 ID:_etC1 cxC3ixVV?huls?ypJyuFUK-QK4cPSEUat2zdOvM9s4DTb5n5vPvlY6proo9XAzUUjq LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 21-23=-54,29-30=-20,24-29=-47(F=-27), 24-33=-20, 3-11 =-1 26(F=-72), 11-21 =-1 26(F=-72) Concentrated Loads (lb) Vert: 29=-641(F) 24=-641(F) ®WARNING - Vertfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall � AV building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IV IiTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?pH Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Salefylnformadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job • Truss Truss Type City Ply T19884603 M11323 GRB HIP 1 1 �M`11323 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL I 5x12 MT18HS = 4.00 12 4x6 = 34 II 3-4-0 4x10 = 2x3 I I 4x6 = 23 4 5 6 5x6 = 6x12 = 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:34 2020 Page 1 5x12 MT18HS = 2x3 11 7 24 6x12 = 5x6 = 3x6 II 34-0-0 Scale=1:58.6 4x6 = N N 0 N IM 0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deb L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.80 Vert(LL) 0.22 16-19 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.68 Vert(CT) -0.30 16-19 >820 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr NO WB 0.90 Horz(CT) 0.06 9 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MS Weight: 153 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-1-14 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 5-3-14 oc bracing. WEBS 2x4 SP No.3 *Except* WEBS 1 Row at midpt 3-14, 8-13, 6-13 4-14,7-13: 2x6 SP No.2 REACTIONS. (size) 2=0-8-0, 13=0-8-0, 9=0-8-0 Max Horz 2=90(LC 7) Max Uplift 2=-853(LC 8), 13=-2590(LC 8), 9=-345(LC 8) Max Grav 2=1451(LC 13), 13=4743(LC 15), 9=528(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3625/1950, 3-4=-2080/1236, 4-6=-2080/1236, 6-7=-1296/2589, 7-8=-1296/2589, 8-9=751 /370 BOT CHORD 2-16=-1729/3460, 14-16=-1753/3525, 11-13=-262/733, 9-11=-241/668 WEBS 3-16=-435/1209,3-14=-15521774,4-14=-837/691,7-13=-878/713,8-13=-3635/1919, 8-11=-432/1204,6-14=-1453/2814,6-13=-3198/1807 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10:0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 853 lb uplift at joint 2, 2590 lb uplift at joint 13 and 345 lb uplift at joint 9. 8) Girder carries hip end with 8-0-0 end setback. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at 26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-8=-131(F=-77), 8-10=-54, 16-17=-20, 11-16=-49(F=-29), 11-20=-20 This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall �• building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/f quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job • Truss Truss Type Ply M11323 T19884603 M11323 GRB HIP �Qty 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL LOAD CASE(S) Standard Concentrated Loads (Ib) Vert: 16=-641(F) 11=-641(F) 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:35 2020 Page 2 I D:SrRaEyyrg04M78G4raWBLWyu FUJ-M iCNg7G16U IgtJ31HH7hYOB9Sj3emSr6J6HG b2zUUjo ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not ?Val* a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke Fast Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job • Truss Truss Type Qty Ply M11323 ]MONO T19884604 M11323 J2 TRUSS 8 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:35 2020 Page 1 ID:x17zSlzTbJ CDI I rGPH 1 Oukyu FU I-MiCNg7Gl6U IgtJ31 H H7hYOBJ7jCDmgz6J6HGb2zUUjo -1-0-0 2-0-0 1-0-0 2-0-0 Scale = 1:7.8 3x4 = 2-0-0 2-0.0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.07 Vert(CT) -0.00 7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 file n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MP Weight: 8lb FT=0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. ' (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=67(LC 10) Max Uplift 3=-28(LC 10), 2=136(LC 10), 4=-3(LC 7) Max Grav 3=39(LC 15), 2=141(LC 1), 4=31(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3, 136 lb uplift at joint 2 and 3 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Data: April 3,2020 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall HV 1- building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additlonal temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPlf quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply T19884605 M11323 J4 MONO TRUSS 8 1 �1011323 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:36 2020 Page 1 ID: PDYLfd_5MdK4MSQTz7ZfRxyuFUH-qvml2TGNtoQXUTexr?ew5DjQW7UmV7DFYm1 p8UzUUjn -1-0-0 4-0-0 1-0-0 4-0-0 Scale = 1:11.1 3x4 = 4-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) 0.02 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.02 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 14 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc pudins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=104(LC 10) Max Uplift 3=-80(LC 10), 2=-161(LC 10), 4=-7(LC 10) Max Grav 3=90(LC 1), 2=207(LC 1), 4=69(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Ex , C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 lb uplift at joint 3, 161 lb uplift at joint 2 and 7 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 14II-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall MiTek* building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing 1 V IiTe k• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSH7P11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job - Truss Truss Type City Ply M11323 T19884606 M11323 J6 MONO TRUSS 8 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:36 2020 Page 1 ID:lP6Jtzj7xSx c_fXi4uz9yuFUG-gvml2TGNtoQXUTexr?ewSDJR?7MUV7DFYm1p8UzUUjn 1-0-0 6-0-0 1-0-0 6-0-0 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.36 TCDL 7.0 Lumber DOL 1.25 BC 0.83 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP No.3 REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=142(LC 10) Max Uplift 3=-131(LC 10), 2=-194(LC 10), 4=-B(LC 10) Max Grav 3=145(LC 1), 2=279(LC 1), 4=102(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. Scale = 1:14.6 DEFL. in (loc) I/deft Ud PLATES GRIP Vert(LL) 0.11 4-7 >629 360 MT20 244/190 Vert(CT) -0.12 4-7 >617 240 Horz(CT) -0.00 3 n/a n/a Weight: 20 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift atjoint 3, 194 lb uplift at joint 2 and 8 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall IV I/� building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing iTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTP/f Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type yPly M11323T19884607 Q M11323 J8MONO TRUSS 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:37 2020 Page 1 I D:tP6jtzj7xSx_c_fXi4uz9yuFUG-J5K7FpH?d 5YO6dD80i99eRGYgXqu EaTPmQmNgxzU Ujm -1-0-0 8-0-0 1-0-0 8-0-0 Scale=1:17.4 3x5 = 8-0-0 a-0-0 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.62 Vert(LL) 0.26 4-7 >367 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.30 4-7 >319 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017ffP12014 Matrix -MP - Weight: 26 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOT CHORD 2x4 SIR M 31 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=180(LC 10) Max Uplift 3=-175(LC 10), 2=-228(LC 10), 4=-15(LC 10) Max Grav 3=188(LC 1), 2=352(LC 1), 4=145(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 24-13 to 3-1-13, Exterior(2) 3-1-13 to 7-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 175 lb uplift at joint 3, 228 lb uplift at joint 2 and 15 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall Sal, building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVlP/f Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety INormation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Type city Ply M11323 �MOsNO T19884608 M11323 KJ8 TRUSS 4 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:38 2020 Page 1 I D: Lcg54J?Lu EancmZr4Qb7 W Myu FU F-nHuVT9ldOPgFknoKyPgOAeooawB GZWZY?4 WwCNzUUjI -10 7-3-4 11-3.0 ' 1-5-SO 7-3.4 3-11-12 Scale = 1:20.3 3x4 = coo 11 5 30 = 7-3-4 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.29 Vert(LL) 0.07 7-10 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.30 Vert(CT) -0.12 7-10 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.46 Horz(CT) 0.02 6 n/a n/a BCDL 10.0 Code FBC2017rrP12014 Matrix -MS Weight: 44 lb FT = 0% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (size) 4=Mechanical, 2=0-11-5, 6=Mechanical Max Horz 2=244(LC 8) Max Uplift 4=-205(LC 8), 2=-305(LC 8), 6=-286(LC 8) Max Grav 4=245(LC 13), 2=466(LC 1). 6=590(LC 13) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1151/523 BOT CHORD 2-7=687/1126, 6-7=-687/1126 WEBS 3-7=0/330, 3-6=-1236/755 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 8-9-6 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. ll; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 205 lb uplift at joint 4, 305 lb uplift at joint 2 and 286 lb uplift at joint 6. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard This item has been 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 electronically signed and Uniform Loads (plf) sealed by Velez, Joaquin, PE Vert: 1-2=-54 Trapezoidal Loads (plf) using a Digital Signature. Vert: 2=0(F=27, B=27)-to-4=-152(F=-49, B=-49), 8=0(F=10, B=1 0)-to-5=-56(F=-1 8, B=-18) Printed copies Of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. W1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall rt �� iTek• building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the iUl fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPI1 Qualify Criteria, DSB-99 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Symbols Numbering System ® General Safety Notes PLATE LOCATION AND ORIENTATION Center plate on joint unless x, y 4 offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 1 Failure to Follow Could Cause Property Damage or Personal Injury Dimensions are in ft-in-sixteenths. 1. Additional stability bracing for truss system, e.g. Apply plates to both sides of truss 1 2 3 diagonal or X-bracing, is always required. See SCSI. and fully embed teeth. TOP CHORDS 2. Truss bracing must be designed by an engineer. For 0' 1/ �� c1-2 c2.3 wide truss spacing, individual lateral braces themselves may require bracing, or Tor 1 16 WEBSa 4 C' �i,� 4 �1 ; = 0 3 y� 3 O alternative bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. U e6 2 n U 4. Provide copies of this truss design to the building O a ~ O0 designer, erection supervisor, property owner and For 4 x 2 orientation, locate c7-8 c6a ca-s all other interested parties. plates 0- 'id' from outside P BOTTOM CHORDS 5. Cut members to bear tightly against each other. edge of truss. 8 7 6 5 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE locations are regulated by ANSI/TP1 1. required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 7, Design assumes trusses will be suitably protected from connector plates. THE LEFT. the environment in accord with ANSIIrPI 1. *Plate location details available In MiTek 20/20 CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. 8. Unless otherwise noted, moisture content of lumber software or upon request. shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for PLATE SIZE PRODUCT CODE APPROVALS use with fire retardant, preservative treated, or green lumber. [CC -ES Reports: 10. Camber is a non-structural consideration and is the The first dimension is the plate responsibility of truss fabricator. General practice is to 4 x 4 width measured perpendicular ESR-1311, ESR-1352, ESR1988 camber for dead load deflection. to slots. Second dimension is ER-3907, ESR-2362, ESR-1397, ESR-3282 11. Plate type, size, orientation and location dimensions the length parallel to slots. indicated are minimum plating requirements. LATERAL BRACING LOCATION 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. Indicated by symbol shown and/or by text in the bracing section of the Trusses are designed for wind loads in the plane of the truss unless otherwise shown. 13. Top chords must be sheathed or pudins provided at spacing indicated on design. output. Use T or I bracing if indicated. Lumber design values are in accordance with ANSI/TPI 1 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. section 6.3 These truss designs rely on lumber values BEARING established by Others. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior Indicates location where bearings approval of an engineer. (supports) occur. Icons vary but © 2012 MiTek® All Rights Reserved reaction section indicates joint 17. install and load vertically unless indicated otherwise. number where bearings Occur. Min size shown is for crushing only. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. Industry Standards: W1 19. Review all portions of this design (front, back, words ANSIfTPl1: National Design Specification for Metal and pictures) before use. Reviewing pictures alone is not sufficient. Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. 20. Design assumes manufacture in accordance with BCSI: Building Component Safety Information, MiTek ANSI/rPI 1 Quality Criteria. Guide to Good Practice for Handling, Installing & Bracing of Metal Plate 21.The design does not take into account any dynamic Connected Wood Trusses. MiTek Engineering Reference Sheet: Mll-7473 rev. 5/1912020 or other loads other than those expressly stated.