Loading...
HomeMy WebLinkAboutAPPROVED Underlayment NEMO j etc. Certificate of Authorization#32455 353 Christian Street, Unit 913 Oxford,Cl'06478 (203) 262-9245 ENGINEER EVALUATE TE5T CONSULT CERTIFY EVAWATION REPORT Carlisle Coatings&Waterproofing Evaluation Report C391W.12.11-R5 900 Hensley Lane FL6785-R9 Wylie,TX 75098 Date of Issuance: 12/09/2011 (717) 245-7000 Revision 5:06/17/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have evaluated for compliance with the 6th Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: CCW Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products)changes,the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.of any changes to the product(s),the Quality Assurance or the production facility location(s). NEM01etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words. °NEMO etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. 1NSPEC11ON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official, This Evaluation Report consists o`pages 1 through 4. Prepared by: Robert J.M.Nieminen,P.E. ' �.,� ,, The hmmiie sea[appearing was authorzed Flarido Regisrraricn No.59166,Florida DCA ANE1983 by Robert Nieminen,P.E-on 06i1712019 Thus does not serve as an electronically signed document. CERrIRCATIOA OF INDEPENDENCE: 1. NEMoIetc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing produc's it evaluates. 2. NEMOletc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the apprcval process of the oroduct- 5. This is a building code evaluation. Neither NEW I etc.nor Robert Nieminen,P.E.are,in anyway,the Resigner of Record for any project on which this Evaluation Report.or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. A&__I 17N EM 01 etc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: CCW Roof Underlayments, as produced by Carlisle Coatings & Waterproofing, have demonstrated compliance with the following sections of the 611 Edition(ZO17)Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /Conditions of Use set forth herein. 2. STANDARDS: Section Prooe Standard Year 1507.1.1,T1507.1.1, 1507.2.9.2, Physical Properties ASTM D1970 2015 R905.1.1,TR905.1.1,R905.2.8.2 1507.3.3,R905-3.3 Physica!Properties FRSA/TRI April 2012(04-i2) 2G12 TAS 110 Accelerated Weathering ASTM D4798 2011 Entity Examination Reference Date ERD(TST6049) ASTM D1970(TX) C412W.10.12 10/05/2012 MTI(TST2508) ASTM D1970(PA) PX02M0A 01/17/2011 MTl(TM508) ASTM D1970 IPA) PX13MOB 01/18/2011 ICC-E5(EVL2396) 20151BC/IRCCompliance ESR-1556 02/01/2018 ICC-ES(EVL2396) 2015 i$C/IRC Compliance ESR-2206 06/01/2018 NFMO(TST6049) FRSA/TRI April 2012(04-12)(PA&TX) 4S-CRL-18-004A2.18-1 12/17/2018 MEMO(TST,6049) ASTM D'_970(adhesion](TX) 4S-CRL-19-004 01/21/2019 NEMO(TST6049) ASTM 01970&D4799(PA) 4j-CRt-19-5SUDL-03.A 05/28/2015 NEMO(TST6049) ASTM D2970(PA) 4j-CRL-I9-SSUDL-02.A 06/03/2019 MEMO(TST6049) ASTM D1970&FRSA/TRI(04-12)(TX) 4S-CRL-18-O04.06.19.A 06/12/2019 UL,LLC.(QUA9625) Quality Control TGDY.R18678 Listing 10/18/2010 UL,LLC-(Qt1A9625) Quality Control Service Confirmation 04/13/2017 4. PRODUCT • Product specification Plants Description 4.1 WIP 100 ASTM D1970 Carlisle,PA self-adhering,fiberglass reinforced,granule surfaced, rubberized asphalt roof underlayment 4.2 WIP 1005G ASTM D1970 Carlisle, PA self-adhering,fiberglass reinforced,granule surfaced, rubberized asphalt roof underlayment 4.3 W{P 250HT ASTM D1970 and FRSA/TRI Carlisle, PA self-adhering,fiberglass reinforced,film April 2012(04-12) surfaced, rubberized asphalt roof underlayment 4.4 WIP 300HT ASTM D1970 and FRSA/TRI Terrell,TX self-adhering,coated-polyclefin-composite film April 2012(04-12) surfaced,rubberized asphalt roof underlayment 4.5 WIP 400HT ASTM D1970 and FRSA/TRI Terrell,TX self-adhering, polypropylene film surfaced, April 2012(04-12) rubberized asphalt roof underlayment 4.6 WIP GRIP ASTM D2970 Carlisle, PA self-adherin¢,fiberglass reinforced.fl-- surfaced, rubberized asphalt roof underlayment NEMO ETC,LLC Evaivation Report C191M.12.11-R6 Certifrcabr 0fAatlr7rir060n 0324S5 V EDITION(2017)FSC NONE-HVHZ EVALUATION FL6785-R9 Carlisle Coatings&Waterproofing,,(717)24S-70M Revision 6:06/17/7019 Page 2of4 OMEMO etc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen,P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report,-refer to current Approved Roofing Materials Directory for fire ratings of this product. 5,4 CCW Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jlurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: RooF CovEitO Asphah wood Shakes& state&synthetic Underlayntent Shingles Nail-on Tile I Foam-CM Tile i Metal B Shingles Slate/Shake WIP 100 Yes No f No No No No WIP 10OSG Yes No No No No No WIP250HT Yes Yes No Yes No No WIP 300HT Yes Yes I No Yes No i Yes WIP 400H7 Yes Yes No Yes No Yes WIP GRIP Yes No No No No Nn 5.6 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS U n de rlayment Primer substrates WIP 100,WIP 250HT (Optional}CCW-7G2 or CAV-GRIP plywood I WIP 100,WIP 25GHT None ASTM D226 felt IP 100sG CCW-702 or CAV-GRIP plywood W 3WHT (Optional}CCW-702 or CAV-GRIP plywood,OSS or ASTM D226 felt WIP 490HT (optional)CCW-702 or CAV-GRIP plywood,0S3 or A5TM D226 felt WIP G P {optional)ASTM D41,CCW-550,CCW-702 or CAV-GRIP plywood ASTM D41,CCW-550,CCW-702 or CAV-GRIP OSB 5,7 Exposure Limitations: WIP 10P and WIP 10OSG shall not be left exposed for longer than 30-days after installation. WIP G lP shall not be left exposed for longer than 90-days after installation. WIP OHT,WIP 300HT and WIP 400HT shall not be left exposed for longer than 180-days after installation 5.8\ Ti151ippage Limitations Iper FRSA/TRI April 2012 (04-12)�: When loading roof tiles on the underlayment in direct-deck tile assemblies, tiie shall be staged atop a fastened batten or toe-board, regardless of slope. NEMO ETC,LLC Evaluation Report C3918D.12.1I-R6 Certi{rateofAuthonza4km#32655 61"EEC€TEON(2017)FRC NON-HVHZ EVALUATION R67US-R9 Carlisle Coatings&Waterproofing;(717)245-7000 Revfoon 5:06/17/2019 Page 3 of 4 I 0 ALI NEMO I etc. 6.1 CCW Roof Underlayments shall be installed in accordance with Carlisle Coatings & Waterproofing published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. Prime the substrate (if applicable) with CCW-702 or CAV-GRIP Primer. Priming is required when temperatures are below 40'F. 6.3 WIP 100, WIP 100SG,WIP 250HT,WIP 300HT,WIP 40GHT and WIP GRIP: i 6-3.1 Non-Tile Applications? Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507-1.1 or R905.1.1 for the type of prepared roof covering to be installed,and CCW published requirements. 6.3.2 Nail-On_Ti_I_e__Applications;WiP 250HT,WfP 300HT or WIP 400HT only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual for Self-Adhered Membrane, and CCW published requirements. For mechanically fastened the roofing over a 2-ply system, consisting of Base Sheet and Self-Adhered Membrane, fastening of the ASTM D226, Type II base sheet steal€ be in accordance with CCW requirements, but not less than that the densities set forth in FRSA/TRI April 2012(04-12),Table 1. Refer to Section 5.8 for tile staging limitations. REQUIREMENTS:7. BUILDING PERMIT As required by the Building Off ciai or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Contact the manufacturer or the named QA entity for plants covered under Rule 61G20-3 CA requirements. Refer to Section 4 herein for product&production locations having met codified physical properties specifications, 9. QUALiTY ASSURANCE ENTITY.' UL, LLC—QUA9625; (847)664-3281 END OF EVALUATION REPORT- NE€bt0 ETC,LLC Evaluation Report C391W.12.11-R6 Cert+fi'cate afA✓thonzaMmSW455 6"EDIT€ON(2017)FBC NON-HVHZ EVALUAT€ON FL6765-R9 Carlisle Coatings&Waterproofing;(717)245-7000 Revision 6:06/17/2019 Page 4 of 4