BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptivq a,nd;Performance Method
Date: C! ! t`1 � 7-o 2,o Permit#: S-Lc, [ CL 10 � T .Q is
Contractor: C a
Job Address: 2y(0°1 J o�� In, �_o IR C9 �i4-A 7k erg e__ 13 q aj1°t
Construction; Vhgl New-Construction-Complete ( Existing-After Addition.
House.Infiltration Test Results S.LC Climate Zone 2
CFM(50) Test_Date:
Volume= �"� 2�?to
ACH(50) CFM(50)x 60 Volume= .�,+�3_I Mechanical Ventilation required less than 3 ACH
Passing results must be&ACH(50)or less Pass ( )Fail
FBC,Energy
The-building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 3 airchanges.per
hour in Climate Zone 1,7 and 3-air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches W.g-(50 Pascals). Testing shall be cgnducted by ether individuals as defined in
Section 553.993(5.)or(7),Florida Statutes or individuals licensed asset forth-in.Section 489.105(3)(f),(g)or(i)or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at anytime after creation of all penetrations of the building
thermal envelope.
FB.C,Residential
Where the air infiltration rate of a dwelling'unit is less than 3 air changes per hour when tested with a blower door at a
pressure of0.2 inch w.c.(50 Pa)in accordance with Section R402.4.1.2 of the Florida Building Code,Energy Conservation
the dwelling unit shall be provided with whole-house mechanical venti4atigtl in accordance with Section.M1507.3,
Testing Company ,
Company Name: Ce-f �� �� 1J� ►ey" �f- Address: «Q t�(e Q r� -
1 hereby,certify that the above House Infiltration.results demonstrate.compliance with BC.Energy Conservation
requirements in accordance with Section i3402A.1,2 ClirnateZone 2.
Signatures
Printed Name.: TSf
License/Certification#: EEC—