Loading...
HomeMy WebLinkAboutConstruction PlansABBREVIATIONS I ELECTRICAL NOTES I JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET —BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY .LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA A RAINTIGHT FILE COPY ST.LUCIE COUNTY PLAN REVIEW BLDG: DATE: ELEC. DATE:��—lo �Ze PLUMB: DATE: MECH: DATE: LICENSE MODULE GROUNDING METHOD: ZEP SOLAR AHJ: St. Lucie County UTILITY. Florida Power and Light 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED POWER —CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY —RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM. PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE- RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE- FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN - RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY- UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL=LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. GENERAL NOTES 1. ALL WORK SHALL -COMPLY WITH THE 2017 FLORIDA BUILDING CODE (6TH EDITION), FLORIDA FIRE PREVENTION CODE (6TH EDITION). 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE. CONFIDENTIAL — THE INFORMATION HEREIN JOB MBEIt J g-3 49 2 3 0 00 aNIUMM CONTAINED MALL NOT BE USED FOR THE Sabrina Grant BENEFIT OF ANYONE EXCEPT TESIA INC., NOR MOIJIMIG SWIM SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 5742 Sunberry Cir PART TO OTHERS OUTSIDE THE RECIPIENT'S Maoul�s Fort Pierce FL 34951 ORGANIZATION, EXCEPT IN CONNECRON WITH THE SALE AND USE OF THE RESPECRVE (24) Hanwho Q—Cells # Q.Peak DUO BLK—G6+/SC340 TESLA EQUIPMENT, WITHOUT THE WIRITTEN INV R PEINS90N OF MU INC. M. SolarEd a Technologies Ltd. # SE760OH—US r24OVI 7723324980 7 SETBACK 00 C VICINITY -MAP 8.16 KW PV ARRAY 27 KWH ENERGY STORAGE SYSTEM PAGE NME. COVER SH FFtONT�� INDEX Sheet 1. COVER SHEET Sheet 2 SITE PLAN Sheet 3 STRUCTURAL VIEWS Sheet 4 UPLIFT CALCULATIONS Sheet 5 THREE LINE DIAGRAM Sheet 6 THREE LINE DIAGRAM Cutsheets Attached REV BY DATE COMMENTS REV A I NAME I DATE COMMENTS * s s s * * * * * * * * Ivan Petrov SHEET RIM. DAIS: 1 a 7/9/2020 T=SLn PITCH: 23 ARRAY PITCH: 23 MP1 AZIMUTH:224 ARRAY AZIMUTH:224 MATERIAL: S-Tile (Cement) STORY: 2 Stories PITCH: 23 ARRAY PITCH: 23 MP2 AZIMUTH:44 ARRAY AZIMUTH:44 MATERIAL: S-Tile (Cement) STORY: 2 Stories Q (E) UTILITY METER & WARNING LABEL m� INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS JEo�]j DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS, Q DC JUNCTION/COMBINER BOX & LABELS Q DISTRIBUTION PANEL & LABELS Q LOAD .CENTER & WARNING LABELS O DEDICATED PV SYSTEM METER Rsfl RAPID SHUTDOWN 0 STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE/FENCE p HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED SITE PLAN N Scale: 3/32" = 1' E 01, 10' 21' W S CONHOENTIAL — THE INFORMATIDN HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR JOB NUM J B-3 49 2 3 0 00 W"`~"` �11w Sabrina Grant 8.16 KW PV ARRAY Uwu,. Ivan Petrov T — 5 L n SHALL IT BE DISCLOSED IN WHOLE OR IN MOUNIING SYSTEM ZEP Mighty Hook 5742 Sunberry Cir 27 KWH ENERGY STORAGE SYSTEM PART TO. OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH Fort Pierce FL 34951 i Maoutl THE SALE AND USE OF THE RESPECTIVE (24) Hanwha Q—Cells # Q.Peak DUO BLK—G6+/SC340 PAGE NAME. am. REV. DATE: TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC INUam. SolarEd a Technologies Ltd. # SE760OH—US r24OV1 7723324980 SITE PLAN 2 a 7/9/2020 (N) PV MODULE sv IZEP SPANNER BAR S1 (E) MOUNTING PLANE (MP) TYPICAL PV SIDE VIEW (6) DIA BOLT & NUT (1) (2) (7) (3) ZEP SPANNER BAR CLAMP STANDOFF (E) TILE (E) ROOF DECKING (5) (4) 5/16° DIA STAINLESSme STEEL LAG BOLT (3-1 /4° EMBED, MIN) LOWEST MODULE SUBSEQUENT MODULES (E) RAFTER 1 STANDOFF NTS INSTALLATION ORDER LOCATE RAFTER, MARK RAFTER LOCATION; -AND REMOVE TILE. (1) PLACE STANDOFF BASE & DRILL PILOT HOLES. AT THE RAFTER. LOCATION. 2) CLEAN PAPER AROUND PILOT HOLE. e 3) ADJUST STANDOFF TO BATTEN HEIGHT. SEAL PILOT HOLES AND BOTTOM (4) OF STANDOFF WITH POLYURETHANE SEALANT. 5) LAG STANDOFF INTO RAPIER. 6) NOTCH TILE WEATHERING TO FIT AROUND STANDOFF. 7) REINSTALL TILE. CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE MEHT OF ANYONE EXCEPT TESIA INC., NOR aoe NUM�R J B-3 49 2 3 0 0 0 `� '� �"M Sabrina Grant 8.16 KW PV ARRAY Ivan Petrov T 5 L n SHALL IT BE DISCLOSED IN AHOLE OR IN MOUM SYSTEMt ZEP Mighty Hook 5742 Sunberry Cir 27 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS Fort Pierce FL 34951 Motes TTHHESAILLEE AND USED INCONNECTION RMEEC11YE� (24) Hanwha Q—Cells # Q.Peak DUO BLK—G6+/SC340 PAGE NMI' SHEET. REk DATE: TESTA EQUIPMENT, IMTHOUT THE WRnTEN PERMISSION OF MIA INC. Iffi R: SolarEd a Technologies Ltd. # SE760OH-US r240Vj 7723324980 STRUCTURAL VIEWS 1 3 a 7/9/2020 ,kimite specific Design Qffarla Design Code' ASM-7 10 Importance Factor 1 URtnate Wind Speed V-llt 160 Fig. 1609A Exposure Category C Section 26.7 Qmnd Snow Load pg 0 Toule 7-1 MP A)ad a Design Won. GUM MP Name YP2 MP1 Roofing S-TAe (Cement) S-Tie (Comont) Standoff 2EP Mighty Heck ZW Mighty Nook Pitch 23 23 S/ k PV MO pef .0.0 pef SL/ALL: Non—PV 110 psf 19.0 psf Standoff Spacing and. Layout MP Nome MP2' MP1 Lando cope X—SDacing Zr 24' Land6w aw Landscape Y—Spacing 39' 39' tandmWe Y—fteaver 16' 16' Pawl: X—Spadiq 24' 2,r Portrait X—Cmtlaw 16' 16' Portrait Y—Spacing 39' 39' Portrait Y—CmNerer 16' 16' Layout Not Staggered Not Staggered X and Y are mmdmums that am always relative to the structure homing that supports the PV. X Is amm rafters and Y b along raRem CONFIDENTIAL — THE INFORMATION HERON OONTKNED MALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR JDB NUMBER: J B-349230 0 0 mt°"� roan Sabrina Grant 8.16 KW PV ARRAY Msuc Ivan Petrov T 5 L. n MODUM SY51Ort SHALL IT BE DISCLOSED IN WOLE OR IN ZEP Mighty Hook 5742 Sunberry Cir 27 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUMDE THE RECIPIENTS ON WITH IN IALLEERANND Fort Pierce FL 34951 r Moou�s THE S uSE OF RESPECCTIIVE (24) Hanwha Q—Cells # Q.Peak DUO BLK—G6+/SC340 PAGE NAME SHHF . REEF. DATE S� olja Ede Technologies Ltd. # SE760OH—US r24OVI TESLA EQUIPMENT, 1MTHOUT THE WRITTEN PERMISSION OF TESLA INC. 7723324980 UPLIFT CALCULATIONS 4 a 7/9/2020 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number. CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number. ACD8329 C-46, C-10 Underground Service Entrance (E) 200A MAIN SERVICE PANEL (E) 20OA/2P MAIN CIRCUIT BREAKER (N) 200A INTERNAL AUTOMATIC RELAY LOAD CENTER 4 200A 2P Z 40A 2P TO NEW ;—I) I I SOLAR N E—n — G — i — ----- -—— -- ( 30A/ 5 FN XNERGN STORAGE FEED THROUGH LUGS i I _ EGCSYSTEM I I ---- I / 30A � EGClGEC — � I. I 5 L1 Z — — — ENERGY Mac! N L2 L1 , N X STORAGE I ' EW� _ _ EGC L SYSTEM LOADS TO 120/240V i RH SINGLE PHASE UTILITY SERVICE (N) 200A 2P TO E LOADS I (E) LOADS TO BE RELOCATED (E) 200A LOAD CENTER Ol (1) 5 8 dx 8 Copper Z (1)Tesla � 123210o-00—E Back—up Gateway 20 NA for AC PW 2.0 6�F' 1 AWG f2 0, THWN-2, Black ®knF (1)AWG #2/0, THWN-2, Black AC — (1) Testa / 1529623—OD—C Ponelaoord Accessory Kit far GW 2.0 NA; 200A, 6sp/12c1r, 120/24OV, 1Ph — (1) CUTLER—HAMM # B 3D230 Break; 30A 2P-3O 2P, 2 Spaces, Quadplex 11��LL (1) AWG /2/0, THWN-2, Black 1 AWG 1HWN-2, Ci sari — ( )....� .................... (1)AWG #10, THWN-2, Black . —(1) BCBreak—H40 2 2 Spat O (1)AWG #10, THWN-2, Red — (1) Eaton / BR245 . (1)AWG #10. THWN-2, White Breaker, 45A, 2P, 120/24OV, Type BR, 10 kAIC, Wire Size #14-4 .... _—(1.)AWG. ID,. TA1WN-2, Green ........ -(1 9011lt Kit; 171/4' EDIT_ .... _ . . iHaM2ooD 2 OA main breaker kit —(1) Metal;B4 Wx4! , Box w/ cover; Nenna 3R X (2)109TESLA AC POWERWALL 2.0,, Home Energy Storage,13.51 M, Stackable, 5.6kVA CONFIDENTIAL — THE INFORMATION HEREIN CONTAINW SHALL NOT BE USED FOR THE INC,INOR aDe NiIYBEk J B-3 49 2 3 0 0 0 Ius st Sabrina Grant DESCRIPTION. 8.16 KW PV ARRAY DMGN. Ivan Petrov T — 5 L n SHALLLIITIT a o�OSm� I� 10UN1°'G Mighty ZEP Mighty Hook 5742 Sunberr Cir Y 27 KM ENERGY STORAGE SYSTEM — PART TO OTHERS OUTSIDE THE RECIPIENTS Fort Pierce, FL 34951 Mwilum ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (24) Hanwho Q—Cells # Q.Peak DUO BLK—G6+/SC340 PAGE NNE SHEET IV. DAIS TE SLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF IESLA INC UNVQt1ER SolarEd a Technologies Ltd. SE7600H—US 240V 7723324980 THREE LINE DIAGRAM 5 a �/9/2020 Voc* = MAX VOC AT MIN TEMP INV 1 — (1) SolarEdge Technologim Ltd. # SE7600H—US L240VJ — (24) Hanwha 0—Cells # O.Peak DUO BLK—G6+/SC340 Inverter, 760OW, 240/203% 997E Son HD Wave w/ZB,AFCI PV Module; 340W, 318 PIC, 40MM, Black Fr, MC4, ZEP, 10MV INV 2 Voc: 40.66 Vpmax: 33.94 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER Inverter 1 SolorEdge Technologies Ltc SE760OH—US r240V1 L1 TO MAIN PANEL Lz AND ENERGY N STORAGE SYSTEM ------ _EGG ------------------------------------- GEC UO 3 t r )AM fa, IMWn—L, DIUCK O (1) AWG /B, THWN-2, Red (1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=32 AAC 7(1)4Wq /8,.1H.WN72,. (;rM , , EGC/GEC, (1)ConduikKit. 3/4 ,EDIT.......... (I) Conduit Kit; 3/4' EMT PV I— 04)SOLARFDGE4 P40G-5NM4MZM PowerBox 0pUrnizer,40OW; ZEP MP 2: 1x12 ----------MJ bgEo MP 1/2: 1x12 DC %Z AM f1U, ry MM CWV, UICCf VUC' = 4ou vul. 15C = 1.7 AUI. O (1)AWG 11% 1HHN/1HWN-2, Green EGC Vmp = 400 VDC Imp=10.07 ADC ..... LLL.... (1)Conduit R. 3H NT...... _ ..... . .................. (P)AWG fl% PV WIre, 60OV, Black Voc* = 480 VDC Isc =15 ADC O (1) AWG j10, 7MN/THWN-2, Green EGC Vmp = 400 VDC Imp=10.07 ADC ....... (1) Canduit Kit. 3/4�. FAIT ...................................... . CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT MA INC., NOR JOB Nlam J B-3 49 2 3 0 00 W'r`""` � "w Sabrina Grant 8.16 KW PV ARRAY �..�� Ivan Petrov T 5 L n SHALL IT BE DISCLOSED IN WHOLE OR IN MOUNTING SMEM: ZEP Mighty Hook 1 5742 Sunberry Cir 27 KWH ENERGY STORAGE SYSTEM � PART TO OTHERS OUISDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH Fort Pierce, FL 34951 MOIwL1s THE SALE AND USE OF THE RESPECTIVE (24) Hanwha Q—Cells # Q.Peak DUO BLK—G6+/SC340TESLA PACE NAtE - s1HEEr IitV DAM I"�1°� SolarEd a Technologies Ltd. SE760oH—US 240V PERMISSION OF � UI�C. THE WRITTEN 7723324980 THREE LINE DIAGRAM 6 a 7 9 2020 / / CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 5742 Sunberry Cir 'battery storage utilized at this facility." UTILITY SERVICE , (2) ENERGY INVERTER AND STORAGE DC DISCONNECT SYSTEM r------- -------------------� SOLAR PHOTOVOLTAIC ARRAYS) L-------------------------- J PHOTOVOLTAIC -BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-349230-00 CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE INC. NOR JOB NUMETR J B-349 230 00 =IURX utawr"m Sabrina Grant 8.16 KW PV ARRAY LIM%. Ivan Petrov T 5 L n Y00N1NG � SHALL T BE o ao DIN MaL ZEP Mighty Hoak 5742 Sunberr Cir 27 KWH ENERGY STORAGE SYSTEM Y PART To OTHERS OUTSIDE THE RECIPIENTS Fort Pierce, FL 34951 MOxM ORGANIZATION. EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (24) Hanwha Q—Cells # Q.Peak DUO BLK—G6+/SC340 S}IfET RI DATE TESLA EQUIPMENT. WITHOUT THE WRITTEN PERMISSION OF TESLA INC. PAGE NAME' 7723324980 SITE PLAN PLACARD 7 a 7/9/2020 Nwm, SolarEd a Technologies Ltd. # SE760OH—US F24OVI Label Location: Label Location: BACKUP LOAD CENTER CAUTION Code: Per TRI POWER SOURCE _Code: SECOND SOURCE IS PHOTOVOLTAIC SYSTEM NEC 408.4TWIRh rni IR('C K CNFR('V CT(1RArF CVCTFNA NEC , ENERGY STORAGESYSTEM ON SITE LOCATED ON ADJACENT WALL Label Location: (BLC) Per Code: NEC 220 Label Location: (MP) Per Code: NEC 312.8.A(3) Label Location: (MP) Per Code: NEC 705.12(B)(3) Label Location: (MP) Per Code: Label Location: (MP) Per Code: Label Location: (MP) Per Code: Label Set Label Location: (MP) Per Code: NEC 705.12.B.2.3.c Label Location: (MP) Per Code: Per 706.7(D) label to be marked in field (AC): AC Disconnect (BLC): Backup Load Center (MP): Main Panel ' ^$018f�1t�/ I ®pSolar Next -Level PV Mounting Technology � S018fClty I ®pSolar Next -Level PV Mounting Technology .ZS Span for concrete the roofs UL LISTED 0 zepsolaccom Description • PV mounting solution for concrete file roofs • Works with all Zap Compatible Modules • Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class °A• Fire Rating when installed using modules from any manufacturer certified as "Type 1" or"Type 2• Specifications Components I I lx 3x U Spanner Bar Part Nos. 850-1400 - 4x 580-1399 - 3x 850-1398 -1x Splice Kit Spanner Clamp Part No. 850-1401 Part No. 850-1194 Listed to UL 2703 Listed to UL 2703 Mighty Hook V2, HDG Interlock Cam Foot Part No. 850-1461 Part No. 850-1388 Part No. 850-1413 Listed to UL 2703 Listed to UL 2703 Listed to UL 2703 • Designed for pitch roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report toASCE 7-05 and 7-10 standards f • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72• and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Ground Zep Array Skirt, Grip, End Caps DC Wire Clip Part No. 850-1172 Part Nos. 850-0113, 850-1421, Part No. 850-1448 ETL listed to UL 467 850-1460, 850-1467 Listed to UL 1565 zepsolar.com Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product The end -user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document#800-1730-001 Rev Date last exported: April 20. 2015 2:14 PM This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product The end -user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolaes products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1730-001 Rev Date last exported: April 20, 2015 2:14 PM solar SolarEdge Power Optimizer - Zep Compatible TM Module Add -On For North America P300-ZEP, P400-ZEP - Certified Zep CompatibleTM' bracket I .. Attaches to module frame without screws' -'reduces on -roof.. labor and,mounting costs Power optimizer equipment grounded through the bracket r Up to 25% more energy Superior efficiency (99.5%) . Mitigates all types of module. mismatch losses, from ' manufacturing tolerance to pArtial shading Flexible system design for maximum space utilization . Next generation maintenance with module -level monitoring Module -level voltage shutdown for installer and firefighter.. - safety USA -CANADA-GERMANY-ITALY-FRANCE-JAPAN -CHINA -AUSTRALIA- THE NETHERLANDS-UK -ISRAEL-TURKEY -HUNGARY-BELGIUM-ROMANIA-BULGARIA wxnvsolaredge.us solar=@@SolarEdge Power Optimizer - Zep Compatible' Module Add -On For North America P400-ZEP P300-ZEP(for60cellPVrdodules)• -P400-ZEP(for72&96tellmodules) INPUT.:.' Rated Input DC power() ..................................................... 399.. ................400.......... W Absolute Maximum Input Voltage (Voc at lowest 48 80 Vdc temperature) .................................................................................................................................................................. MPPT Operating Range: ...................................................... 8 - 48 8-80 ............................. .......................... Vdc ..... Maximum Short Circuit Current (ISO 10 104 Adc ............................................ Maximum DC Input Current ...................... ......:............................................................................ 12:5........... 12.63.................... ........................ Adc Maximum Efficiency ......................... .....99:?..................................*A...... Weighted Efficiency 98.8 ............................................................................................ .............. Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) - - • . Maximum Output Current 15 Adc .............................g............................................................:..................................................................... Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER -OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC. Class B, IEC61000-6-2, IEC61000-6-3 ............................................................................................................................................................................. Safety IEC62109-1(class ll safety), UL1741 .............. RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage ................................ ... 1000 ................................ Vdc Dimensions including mounting bracket (WxLxH) 128 x 196 x 27.5 / 5 x 7.71 x 1.08 128 x 196 x 35 / 5 x 7.71 x 1.37 mm / in ................................................................................................................ Dimensions excluding mounting bracket (WxLxH) 128 x 152 x 27.5 / 5 x 5.97 x 1.08 ......:...................................................... 128 x 152 x 35 / mm / in 5x5.97x1.37 ......................................................................................... .......... Weight. (including cables and mounting bracket) ...... 720 / 1.6 .................... ........................................................... 840 / 19 ...................... kg / lb Input Connector ............................................................................................................................................................................... MC4 Compatible Output Connector .................................................................................................................. Double Insulated; MC4 Compatible ............................................................. Output. Wire Length 0.9.51.3.0 3.0 I 1.2 / 3.9 ................................................................................. m / ft Operating Temperature Range.............................................................40-+85/.-40-+185..................................... .'C/'F ........... Protection Rating................................................................................ ,.IP68 / NEMA 6P.............. Relative Humidity 0 -100 % ul Rated STC power of the module. Module of up to+5%power tolerance allowed. PV SYSTEM DESIGN USING'A ' . SINGLE PHASE THREE PHASE ' THREE PHASE . SOLAREDGE•INVERTERi=J HD -WAVE SINGLE PHASE208V 480V' . Minimum String Length (Power Optimizers) ....................... ................................................................................:....................................... 8 10 18 ...... ....... ................. Maximum String Length (Power Optimizers) 25 25 50 .......................................................................................................................................................................... Maximum Power per String ........................ .................................. 5700 (6000 with SE7600H-US) ......................... 5250 ......................... ......................... 6000 12750 ......................... W ............. Parallel Strings of Different Lengths or Yes Orientations............................................................................................................................................... fV For detailed string sizing Information refer to: http://www.solamdge.com/sites/default/flies/string_sizing_na.pdf. POWERWALL Tesla Powerwall is a fully -integrated AC battery system for residential or light commercial use. Its rechargeable lithium -ion T: = 5 L battery pack provides energy storage for solar self -consumption, time -based control, and backup. Powerwall's electrical interface provides a simple connection to any home or building. Its revolutionary compact design achieves market -leading energy density and is easy to install, enabling owners to quickly realize the benefits of reliable, clean power. PERFORMANCE SPECIFICATIONS AC Voltage (Nominal) 120/240 V Feed -In Type ---------- ----------- .- Split Phase -' - --------------- ---- -------------- ---- ---------_-- Grid Frequency 60 H7 --------------- ------ --- ------------- ---------- -------------------------------------- ---------- -------- --- Total Energy' ------------ 14 kWh - ----- '---------- -------------------- --------------------- -------------- Usable Energy' ------------------------------------------- 13.5 kWh -------------- ------------------- ----- ----------- ------------------------- Real Power, max continuousz ----------- ----------------------------- 5 kW (charge and discharge) ---.----------------------------------------------------------------------------------- Real Power, peak (10s, off-4rid/backup)2 7 kW (charge and discharge) _ -- - - - ----- --------- --- - - -------------- ---- ----- Apparent Power, max continuous ' - ---- - -- -- 5.8 kVA (charge and discharge) — -- ------------ --_----------- -- --- ---- - - ---- -- — ----- — - Apparent Power, peak (10s, off-grid/backup) 7.2 kVA (charge and discharge) — — - - - --- - - - -- — - - .. ---- ---------- ------------- -- - - -_ Maximum Supply Fault Current -------------- 10:kA ---------- ----------------------------- ------------- ----- -------- ----------- ------- Maximum Output Fault Current 32 A ------------------------ ---_.-----------------------'--------------- Overcurrent Protection Device .....------------------......-----.-... 30 A ---- ----------- --- - ----___---'--'-------_-__-.__----------------__-___--------------------__.--- Imbalance for Split -Phase Loads 100% ----------------- ---- ------ --------------- ------ --- - ---- ------ --- ----- ----- -----------_- Power Factor Output Range --- -------- - / 1.0 ad ustable Power Factor Range (full -rated power) -+/- 0.85 - - --------- ---------------------------- ------ - --------------- Internal Battery DC Voltage 50 V _ _ _ _ _-_ _ _ _ _ _ _ ___--.__. _ _ _ _ Round Trip Efficiency'' _ 90% - -------------------------------------------------------------------- Warranty 10 years 'Values provided for 250C (77°F)• 3.3 kW charge/discharge power. — 21n Backup mode, grid charge power is limited to 3.3 kW. 'AC to battery to AC, at beginning of life. COMPLIANCE INFORMATION Certifications UL 1642, UL 1741, UL 1973, UL9540 IEEE 1547 UN 38.3 Grid Connection Compatibility - - Emissions - -Worldwide - - FCC Part 15 Class B, ICES 003 - ----- --------------- --- -------- Environmental ------------- ------------------ -- -- ------------- RoHS Directive 2011/65/EU -------- --------- ----------------------------------------------------------------------------- Seismic AC156, IEEE 693-2005 (high) 7 - L5 L i:i MECHANICAL SPECIFICATIONS Dimensions' 1150 mm x 753 mm x 147 mm (45.3 in x 29.6 in x 5.75 in) Weight' 114 kg (251.3 Ibs) ---- ----------- ------- --------- ------ ---------------- ------------ --------- Mounting options Floor or wall mount ----------- ... 'Dimensions and weight differ slightly if manufactured before March 2019. Contact Tesla for additional information. 753 mm 147 mm (29.6 in) (5.75 in) 4 e 0 L Fi 1150 mm (45.3 in) ENVIRONMENTAL SPECIFICATIONS Operating Temperature -200C to 500C (-4°F to 122°F) -------------- Recommended Temperature 0°C to 300C (320F to 86°F) --------------------------------------------------------------------------- Operating Humidity (RH) Up to 100%, condensing ----------------------------._:.-------- Storage Conditions ---------- -------------- -- -------------- -200C to 300C (-4°F to 86°F) Up to 95% RH, non -condensing State of Energy () SoE : 25% initial ---------------------------------------------------------------------------------------------------------- Maximum Elevation 3000 in (9843 ft) ---- ----------------- - ---- ----- ------- .---------------------------------- Environment ------------------------------- Indoor and outdoor rated ------ ------- ------ ------- ---- ----- ---- Enclosure Type ---------------- -------- — - - - - NEMA 3R ---------------------------------------------------------------------------------------- Ingress Rating IP67 (Battery & Power Electronics) -------------------------------------------------------------------------------------- IP56 (Wiring Compartment) Wet Location Rating Yes ---- ---------- ----- -------------- -- ------- ------------------ Noise Level @ 1m ---- ------- ------- --------- ---------------- < 40 dBA at 300C (86°F) TESLA.COM/ENERGY TYPICAL SYSTEM LAYOUTS WHOLE HOME BACKUP ------------------------ Optional; � I i Solar Solar inverter i F T 5 5 L n Powerwall . PARTIAL HOME BACKUP Main panel Whole home backup --------------------------- Optional � I � Z Solar o 0 Solar inverter ------------------- Sub panel T 3 5 L n n Powerwall Backup loads T _ S L n Backup Gateway including service disconnect Utility meter Grid Backup Gateway Main panel Utility meter Grid Home loads TESLA.COM/ENERGY Optimized installation with HD -Wave technology / Specifically designed to work with power optimizers / Record -breaking efficiency / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Fixed voltage inverter for longer strings / Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 solaredge.com / UL1741 SA certified, for CPUC Rule 21 grid compliance / Extremely small / Built-in module -level monitoring / Outdoor and indoor installation / Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) solar =@@ / Single Phase Inverter Wit HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US SE300OH-US80 1O1 600 .0O000O APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211 - 240 - 264) AC Output Voltage Min.-Nom.-Max. _ ✓ ✓ ✓ Vac (183 - 208 - 229) AC Frequency (Nominal) 59.3 - 60 - 60.5m Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V Maximum Continuous Output _ 16 24 - 48.5 A Current @208V Power Factor 1, adjustable -0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Yes Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 1 9300 1 11800 1 15500 1 17650 W Maximum DC Power @208V 5100 7750 15500 W Transformer -less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240Va) 8.5 10.5 13.5 1 16.5 20 27 30.5 Adc Maximum Input Current @208V(1) - 9 1 - 13.5 27 Adc Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600ka Sensitivity Maximum Inverter Efficiency 99 99.2 CEC Weighted Efficiency gg 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W a For other regional settings please contact SolarEdge support 0 A higher current source may be used; the inverter will limit its input current to the values stated / Single Phase Inverter wit HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US SE3000H-US SE380OH-US SE5000H-US SE6000H-US SE760OH-US SE1000OH-US SE1140OH-US Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional(') Inverter Commissioning with the SetApp mobile application using built-in Wi-Fi station for local connection Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD. COMPLIANCE Safety UL1741, OL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1S47, Rule 21, Rule 14 (Hl) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 3/4' minimum / 14-6 AWG 3/4' minimum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 3/4' minimum / 1-2 strings / 14-6 AWG 3/4' minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22110 25.1 / 11.4 262 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(4) 'F /'C Protection Rating NEMA 4X (Inverter with Safety Switch) m Revenue grade inverter P/N: SE)o=H-USOOOBNC4 (" Full power up to at least 50'C / 122'F,, for power de-ratlng information refer to: httpsV/www.solaredge.com/sites/defaulVfiles/se-temperature-derating-note-na.pdf ® SolarEdge Technologies, Inc All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc All RoHS other trademarks mentioned herein are trademarks of their respective owners. Date: 12019N01/ENG NAM. Subject to change without notice. POWERWALL Backup Gateway 2 The Backup Gateway 2 for Tesla Powerwall provides energy management . and monitoring for solar self -consumption, time -based control, and backup. The Backup Gateway 2 controls connection to the grid, automatically detecting outage's and providing a seamless transition to backup power. When equipped with a main circuit breaker, the Backup Gateway 2 can be installed at the service entrance. When the optional internal panelboard is installed, the Backup Gateway 2 can also function as a load center. The Backup Gateway 2 communicates directly with Powerwall, allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. PERFORMANCE SPECIFICATIONS AC Voltage (Nominal) 120/240V ---------- --------- ---------------------------- ---------------------------------------------- Feed-In Type Split Phase ----------------------------------------------------------------------------------- Grid Frequency 60 Hz — -- --- - — -- - ---- Current Rating ------ -------- ------- --- -- 200 A -----------------------=--------------------------------------- Maximum Input Short Circuit Current 10 kA1 -- — ----------- — -- ------------------------...---------------------------------------- Overcurrent Protection Device 100-20OA: Service Entrance Rated --- - ----------------------- --- .... - '---- ---- ---- ------------- Overvoltage Category -- - -- - - ------------_------ Category IV ------------------------- ------------ -------------- -- - AC Meter — - - -------------------------------- --.... Revenue accurate (+/- 0.2 %) -- --- -- ------------------------- Primary Connectivity --- -------------------------- ---------------------.... Ethernet, Wi-Fi Secondary Connectivity Cellular (3G, LTE/4G)z ---------------- ------ - ---------- - ------------------ User Interface - -- -— ------------------------.__... Tesla App Operating Modes, Support for solar self -consumption, time -based control, backup, and -- ----- off -grid - — --- - - - -- -- Backup Transition -- - ---- -------- -------- •------ ----- Automatic disconnect for seamless backup --------------------------------------------------------------------------------------------------------------------- Modularity Supports up to 10 AC -coupled Powerwalls ------------------ ---------- ------------------ ---------- Optional Internal Panelboard --------- --------------------------------------------- 200A 6-space / 12 circuit Eaton BR Circuit Breakers Warranty ----------- -- 10 years 1 When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. ] The customer is expected to provide internet connectivity for Backup Gateway 2; cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. COMPLIANCE INFORMATION Certifications UL 67, UL 869A, UL 916, UL 1741 PCS CSA 22.2 0.19, CSA 22.2 205 Emissions FCC Part 15, ICES 003 MECHANICAL SPECIFICATIONS ------------------ -------- --------------- ---- --------------------------------------- ------ Dimensions 660 mm x 411 mm x 149 mm (26 in x 16 in x 6 in) Weight 20.4 kg (45 lb) Mounting options Wall mount, Semi -flush mount 6 149 ENVIRONMENTAL SPECIFICATIONS Operating Temperature -200C to 500C (-4°F to 122°F) ------------------ ----- --- ----- -- ---------------------------- Operating Humidity (RH) ------- --- ------ Up to 100%, condensing - ------------------------------------- Maximum Elevation -- - ------------- --------- ---------..._.. 3000 m (9843 ft) --------------------------------------------------------------------------------- Environment Indoor and outdoor rated ----------- -- ------------------------------------------------------------- Enclosure Type NEMA 3R T 5 L r`1 .:i� 2C;2U'J5 25 TESLA.COM/ENERGY powered by. MECHANICAL SPECIFICATION (6 iD U16 Format 68.5 x 40.6 x 1.57in (including frame) (1740 x 1030 x 40 mm) 08 Weight 47.4lbs(21.5kg) Front Cover 0.13 in (3.2 mm) thermally pre -stressed glass with anti -reflection technology Back Cover Composite film Frame Black anodized aluminum Cell 6 x 20 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98 x 1.26-2.36 x 0.59-0.71in (53-101 x 32-60 x 15-18 mm), Protection class IP67, with bypass diodes Cable 4mm2Solar cable; (+)>-43.31n(1100mm),(-)2:43.31n(1100mm) Connector Steubli MC4; IP68 ' QCELLS ' GpMPgT�9 � `-TOP _RAND PV., N / ; � Product end • • � � Perto,mence Wertanry j�AC�MPP��w •,2019 � C�CELLS Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.5%. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID and Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.QTM'. ZEP COMPATIBLETm FRAME DESIGN ] High-tech black Zep Compat[bWm frame, for improved aesthetics, J easy installation and increased safety. A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year r r linear performance warrantyz. Q� STATE OF THE ART MODULE TECHNOLOGY of , Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. ' APT lest conditions according to IEC/TS 62804-1:2015, method B (-1500 V, 168 h) 2 See data sheet on rear for further information THE IDEAL SOLUTION FOR: Rooftop arrays on commercial and Industrial buildings G (1746mm) er4•(osomm) )brt 7. e40nvin,• PWN4e16•(4mm) 'ea7 cmm° °ae•(a 4I e.om..a°°P.roro 6.FMLgpotN,(DEfAep 616•Y�•17.6mmae _6T(4e-) 9Er46.A °A H teFTlr7mm) I-�.Loss6•/9 mml ELECTRICAL CHARACTERISTICS a4smm.) orrsmmm) etmm) brp0.temm) ' POWER CLASS 330 336 ' 340 346 , MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +5 W /-0 W ) Power at MPP' P,•,pp [W] 330 335 340 345 Short Circuit Current' Is, [A] 10.41 -10.47 10.52 10.58 E E Open Circuit Voltage' Vcc IV] 40.15 40.41 40.66 40.92 Current at MPP I_ [A] - 9.91 9.97 10.02 10.07 Voltage atPP r/Mpp [V] 33.29 33.62 33.94 34.25' Efficiency' rl [%] 218.4 >_18.7 >19.0 t19.3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 ' Power at MPP PNpp [W] 2470 250.7 254.5 258.2 E Short Circuit Current Isc [A] 8.39 8.43 8.48 8.52' E Open Circuit Voltage e Voc IV] 37.86 38.10 38.34 38.59 Current at MPP IwP [A] 7.80 7.84 7.89 7.93 Voltage at MPP Vmw IV] 31.66 31-97 32.27 32.57 'Measurement tolerances PMpp t3%; Isc; Voc 35%at STC: 1000w/m2, 25x2°C. AM 1.5 according to IEC 60904-3.2800 W/m?, NMOT, spectrum AM 1.5 O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98%of nominal power during first year. Thereafter max. 0.54% c ----------------------------- degradation per year. At least 93.1% bof nominal power up to 10 years. At 4z '0 "-------'---- least 85% of nominal power up to tl25 i years. 3 .° --r'-----r----- i ----- r----- i o oAll data within measurement toleranc- es. Full warranties in accordance with :eo - aoo 11. to uoo the warranty terms of the O CELLS iRano)aNCErwi,efl o >e sales organization of your respective m country. YEAR_ Typical module performance under low irradiance conditions in a Mm�w.pr.w.6 P 6u ' comparison to STC conditions (25°C, 1000 W/m2) TEMPERATURE COEFFICIENTS Temperature Coefficient of Isc a [%/K] +0.04 . Temperature Coefficient of Voc d [%/K] -0.27 Temperature Coefficient ofPepp y [%/K] -0.36 Normal Module Operating Temperature NMOT [°F] 109t5.4(43t3°C) PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage Vas IV] 1000 (IEC)/1000 (UL) Protection Class II Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/ UL 1703 C (IEC)/TYPE 2 (UL) Max. Design Load, Push/ Pull (UL)' [Ibs/ft2] 50(2400Pa)/50(2400Pa) Permitted Module Temperature --40°Fupto+185°F Max. Test Load, Push/ Pull (UL)° [Ibs/112] 75(3600Pa)/75(3600Pa) on Continuous Duty (-40°Cupto+85°C) 'See Installation Manual QUALIFICATIONS AND CERTIFICATES UL 1703, CE-compliant, IEC 61215:2016. IEC 61730:2016, Application Class II, U.S. Patent No. 9,893,215 (solar cells) C E e SA D E c�,°„us Note: Installation instructions must be followed. See the Installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha Engineered in Germany OCELLS 400 SpecOtruCm CenternDrive, Suite 1400, Irvine, CA 92618, USA I TEL+1949 748 59 96 I EMAIL InquiryQus.q-cells.com I WEB www.q-cells.us