Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
cooper unpermitted 3
GSPublisherVersion 0.0.100.100 UNPERMITTED RENOVATION6740 N Hwy A1A, Ft Pierce, FL 34949A-1 floor plans 9/22/20IDDATECOMMENTFL Design Build InspectConstruction + Architecture+ Home InspectionCRC1331263 | AA26003142 | HI10776772.321.4500frank.liebler@gmail.comwww.FLDesignBulidInspect.com© ALL IDEAS, DESIGNS, PLANS AND ARRANGEMENTS INDICATED ON THIS SHEET ARE THE PROPERTY OF FL DESIGN BUILD INSPECT, AND WERE CREATED, EVOLVED AND DEVELOPED FOR THIS SPECIFIC PROJECT.S H E E T prior 1st level cond area 682 sf former garage 863 sf proposed 1st level cond area 1,545 sf proposed cond volume 13,596 cf A-1 A-2 GN-1 floor plans elect gen notes 2-8x6-8 2-8x6-8 2-4x6-8 5'-1" 12'-10"8'-8" 4'-6 1/4" 11'-1" 8'-11 3/4"23'-10" 12'-5" 5'-6"4'3'-7"10'-5 1/2" SOW-4 SOW-9 D2,3,4 BUCKS: DBL 2x6. FIRST 2x ATTACHED TO CMU W/ 1/4" x 2.75" TAPCON @ 12" OC/6" END. TOP 2x TO FIRST 2x W/ #9 3" SCREW OR 10 D NAIL @ 12" OC. EXTG AC PAD fl el: -6"fl el: 0" fl el: 0"fl el: -6"STAIRSUTILITYLAUND BA GAME.R 1 GAME.R 2 AHU SK(2) E-PANELSHWH FOUNDATION FOR SPLIT LEVEL ABOVE SK shelves cabinets cabinets SWR FOYER ABOVESTAIRSD2D3D4D1W1D5W2W3clg el: 9' CU DR WA 23'-10" 18'-3 1/2"8'-8" 4'-6 1/4" 20'-5 1/4"5'-1" 12'-10" 8'-6" 9'-5"4'-6 1/4"4'3'-7"10'-5 1/2"34'-4 1/2"SOW-4 SOW-9 EXTG AC PAD fl el: -6" fl el: 0"fl el: -6"STAIRSUTILITYLAUND GAME.R 2 AHU (2) E-PANELSFOUNDATION FOR SPLIT LEVEL ABOVE HWH BA GARAGE SK SK FOYER ABOVESTAIRSfl el: -6" clg el: 9' CU DR WA SCALE: NTS4"5"SHOWER RECESS #3 REBAR 18" OC EW, OMIT IF FIBERMESH USED CONC OVER 6 MIL VB OVER COMPACTED & TERMITE TREATED FILL EXISTING SLAB #3 REBAR 4" EMBED @ 18" oc #3 REBAR 18" OC EW, OMIT IF FIBERMESH USED CONC OVER 6 MIL VB OVER COMPACTED & TERMITE TREATED FILL NEW SLAB FORMER GARAGE SLAB SLAB INFILL /TOPPING DETAIL ID ACTUAL D. PRESSURES W H DESCRIPTION D1 42.5,‐54.7 6‐0 8‐0 D. SWING, GLAZED D2 42.5,‐54.7 8‐0 6‐8 D. SWING, GLAZED D3 42.5,‐54.7 8‐0 6‐8 D. SWING, GLAZED D4 42.5,‐54.7 8‐0 6‐8 D. SWING, GLAZED D5 6‐0 6‐8 EXISITING TO REMAIN DOOR SCHEDULE SEE GEN NOTE 26 ID ACTUAL D. PRESSURES W H B.O. LINTEL TYPE NOTES W1 2‐9 3‐4 6‐8 S. HUNG EXISITING TO REMAIN W2 2‐9 3‐4 6‐8 S. HUNG EXISITING TO REMAIN W3 2‐9 3‐4 6‐8 S. HUNG EXISITING TO REMAIN WINDOW SCHEDULE SEE GEN NOTE 26 SCALE: 1/2"= 1'1'-10"EXTG 1/2" DW EXTG PLY OVER EXTG TRUSS @ 24" OC EXTG SLAB/FTG NEW BRG WALL (NO UPLIFT): 2x4 @ 16" OC. DBL TP. TP TO TRUSS WEB W/ S. H6 @ 24" OC. BP TO EXTG FTG W/ .5" x 6" WEDGE BOLT @ 32" OC DEMO UNPERMITTED BEAM BRG WALL DETAIL EXTG/DEMO 1ST LEVEL FLOOR PLAN SCALE: 1/4"= 1'-0" SHEET INDEX NEW 1ST LEVEL FLOOR PLAN SCALE: 1/4"= 1'-0" FEMA ANALYSIS: The structure is noncompliant with FEMA regulations due to not having a pile foundation. All the conditioned spaces, including the lower level, are above the design flood elevation (DFE). BFE: VE-11' DFE: 12' navd Existing elevation of the 1st level: 12.3' navd Contractor to provide a cost breakdown which shows the project does not exceed the substantial imorovement classification. SCOPE OF WORK- SEE KEYNOTES IN PLAN LABLED (SOW): U- UNPERMITTED, N-NEW WORK TO CORRECT UNPERMITTED 1. U- CONVERSION OF A 3 CAR GARAGE TO CONDITIONED SPACE 2. U- RELOCATE BATHROOM 3. U- RELOCATE & REPLACE HWH W/ NEW GAS HWH 4. U- INFILL EXTERIOR DOOR W/ NON REINF CMU 5. U- WINDOWS & REAR SLIDER WERE PERMITTED & FINALED IN 2017 6. U- RECONFIGURE WALLS 7. U- CONC TOPPING OVER FORMER GARAGE SLAB, 5" THICK W/ NO WIRE, BONDED TO FORMER GARAGE SLAB W/ BONDING AGENT. 8. N- NEW MINI SPLIT AHU 9. N- REBUILD LOAD BRG FRAME WALL WHICH WAS REMOVED, SEE BRG WALL DETAIL PROJECT DESCRIPTION UNPERMITTED RENOVATION/ GARAGE CONVERSION TO COND AREA. ZONING INFORMATION: parcel id: 1403-120-0003-010-3 Hutchinson Island (St Lucie County) UTILITY INFORMATION: gas: none sewage: septic potable water: well AREA CALCULATIONS : GSPublisherVersion 0.0.100.100 UNPERMITTED RENOVATION6740 N Hwy A1A, Ft Pierce, FL 34949A-2 elect 9/22/20IDDATECOMMENTFL Design Build InspectConstruction + Architecture+ Home InspectionCRC1331263 | AA26003142 | HI10776772.321.4500frank.liebler@gmail.comwww.FLDesignBulidInspect.com© ALL IDEAS, DESIGNS, PLANS AND ARRANGEMENTS INDICATED ON THIS SHEET ARE THE PROPERTY OF FL DESIGN BUILD INSPECT, AND WERE CREATED, EVOLVED AND DEVELOPED FOR THIS SPECIFIC PROJECT.S H E E T HWH CONDENSATE LINE TO SHARE AHU CONDENSATE AHU SK(2) E-PANELSHWH SK SWR NEW WC 3" EXTG WA 2", 2" VENT DEMO WC 3" EXTG VENT 2" NEW SK 1.5" DEMO SK 1.5" DEMO SWR 2" NEW SWR 2" NEW SK 1.5" DR WA 2-8x6-8 2-8x6-8 2-4x6-8 2' EXTG AC PAD STAIRSL2 L2 LAUND BA GAME.R 1 GAME.R 2 AHU SK(2) E-PANELSHWH FOUNDATION FOR SPLIT LEVEL ABOVE SK SWR FOYER ABOVESTAIRSL2 EXHAUST2"INTAKE2" 22,400 BTU MINI SPLIT CU DR WA SSL5 L4EXL SSS E2 E-DRYE-WAE1E2 E1E1 E1 L1 L1L1 L1L1 L1L1 L1L6 L1 L1 L1 L1 L1 L1 SSS SEXTG(2) E-PANELSE1 E1E1E1 E1E1 E1 E1E1 E1E1E1E1 E1 SD L5 S NEW 1ST LEVEL ELECT/MECH PLAN SCALE: 1/4"= 1'-0" NEW 1ST LEVEL DWV PLUMBING PLAN SCALE: 1/4"= 1'-0" GSPublisherVersion 0.0.100.100 UNPERMITTED RENOVATION6740 N Hwy A1A, Ft Pierce, FL 34949GN-1 gen notes 9/22/20IDDATECOMMENTFL Design Build InspectConstruction + Architecture+ Home InspectionCRC1331263 | AA26003142 | HI10776772.321.4500frank.liebler@gmail.comwww.FLDesignBulidInspect.com© ALL IDEAS, DESIGNS, PLANS AND ARRANGEMENTS INDICATED ON THIS SHEET ARE THE PROPERTY OF FL DESIGN BUILD INSPECT, AND WERE CREATED, EVOLVED AND DEVELOPED FOR THIS SPECIFIC PROJECT.S H E E T COMPONENT AND CLADDING LOADS… FROM TABLE FBC R301.2(2) EFFECTIVE WIND AREA (SF) 4 10.0 44.6 ‐48.3 4 20.0 42.5 ‐45.1 4 50.0 39.8 ‐43.5 4 100.0 37.8 ‐40.3 4 500.0 33.2 ‐35.4 5 10.0 44.6 ‐59.6 5 20.0 42.5 ‐54.7 5 50.0 39.8 ‐49.9 5 100.0 37.8 ‐45.1 5 500.0 33.2 ‐35.4 1.61 adjustment factor used Wall ZONE 160 WIND PRESSURES (asd) BASIS OF STRUCTURAL DESIGN:GENERAL NOTES- residential 1. CODE COMPLIANCE: 1.1. This project was designed under the following codes. The construction documents cannot reference all of the codes require for the construction of this building. By submitting these construction documents for permit or commencing work, the contractor, hereby agrees to comply with all local, state, and federal regulations having jurisdiction over this project, and to comply with all governing codes, including but not limited to, the most current editions as adopted by the state of Florida, of the following: 2017 FBC: RESIDENTIAL, 6th ed 2017 FBC: ENERGY CONSERVATION, 6th ed 2014 NATIONAL ELECTRIC CODE 2. ALL GENERAL NOTES 2.1. THE FOLLOWING SPECIFICATIONS ARE MINIMUM REQUIREMENTS TO SUPPLEMENT THE DRAWINGS. IN CASE OF CONFLICT, NOTIFY ARCHITECT. THESE DRAWINGS, IN CONJUNCTION WITH OTHER SUBMITTALS, REPORTS, OR WRITTEN INSTRUCTIONS BY ARCHITECT OR CONSULTANTS, SHALL BE CONSIDERED THE COMPLETE CONSTRUCTION DOCUMENTS. 2.2. THE FOLLOWING GENERAL & SPECIFIC NOTES SHALL APPLY EQUALLY TO ALL CONTRACTORS , SUBCONTRACTORS, AND SUPPLIERS ENGAGED IN EXECUTION OF WORK ON THESE PLANS. 2.3. GENERAL CONTRACTOR SHALL FURNISH A COMPLETE SET OF DRAWINGS AND ADDENDUM'S TO ALL SUBCONTRACTORS ON THE JOB AND COORDINATE THEIR WORK. ANY DISCREPANCIES AND/OR CONFLICTS IN THE DRAWINGS SHALL BE NOTIFIED TO THE ARCHITECT BEFORE PROCEEDING WITH ANY INSTALLATION. FAILURE TO DO SO WILL BE THE ENTIRE RESPONSIBILITY OF THE GENERAL CONTRACTOR. ANY COSTS ARISING TO CORRECT THE DISCREPANCY AND/OR CONFLICT SHALL BE BORNE BY THE RESPONSIBLE PARTY. 2.4. NO DEVIATION OF THE APPROVED SET OF DRAWINGS WILL BE MADE IN THE FIELD WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ARCHITECT AND BUILDING OFFICIAL. IN SUCH CASE THE ARCHITECT SHALL PREPARE A REVISION IN ACCORDANCE WITH THE CHANGE. APPROVAL FROM THE BUILDING OFFICIAL SHALL BE OBTAINED BY THE CONTRACTOR BEFORE PROCEEDING WITH ANY WORK. 3. ARCHITECT & CONTRACTOR RELATIONSHIP 3.1. UNLESS CONTRACTED DIRECTLY BY CONTRACTOR, THE ARCHITECT AND CONTRACTOR ARE NOT IN A CONTRACTUAL RELATIONSHIP, THE ARCHITECT IS AN AGENT OF THE OWNER. BY SUBMITTING THESE CONSTRUCTION DOCUMENTS FOR PERMIT, THE CONTRACTOR ACKNOWLEDGES THAT THEY ARE COMPETENT, UNDERSTAND THE DOCUMENTS, AND ARE BOUND BY THE TERMS OF THE DOCUMENTS. IF THE CONTRACTOR VEERS FROM THESE PLANS, THEY ARE ACCEPTING LIABILITY THAT MAY ARISE DUE TO CHANGES. ARCHITECT IS NOT LIABLE FOR THE CONTRACTOR’S INCOMPETENCY TO UNDERSTAND THE CONSTRUCTION DOCUMENTS. IT IS NOT THE ARCHITECT'S ERROR OR OMISSION IF THE ARCHITECT DOES NOT SPECIFY/REFERENCE SOMETHING THAT IS REQUIRED BY THE CODES MENTIONED, THE CONTRACTOR AND SUBS ARE REQUIRED TO UNDERSTAND AND ADHERE THE BLDG CODES NO DIFFERENT THAN THE ARCHITECT. 4. WORKMANSHIP: 4.1. ALL WORK SHALL BE PERFORMED IN THE BEST AND MOST PROFESSIONAL MANNER BY CRAFTSMEN SKILLED IN THEIR RESPECTIVE TRADES. 5. COORDINATION: 5.1. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF WORK FOR ALL TRADES. 5.2. A DRAWING MAY INADVERTENTLY OMIT SOME RELATED ITEM FROM ANOTHER DRAWING. THIS DOES NOT MEAN THAT THE SECONDARILY OMITTED ITEM IS NOT REQUIRED IN SO FAR AS IT AFFECTS THE TRADES. ALL TRADES SHALL INCLUDE EVERYTHING NECESSARY FOR A COMPLETE AND PROPERLY FUNCTIONING CODE - ACCEPTABLE PROJECT, UNLESS CERTAIN ITEMS ARE SPECIFICALLY INDICATED AS BEING PROVIDED BY OTHERS AS "NIC" (NOT IN CONTRACT). 7. CONDITIONS NOT DETAILED: 7.1. CONSTRUCTION DOCUMENTS CANNOT DETAIL EVERY CONDITION OR INSTRUCT THE CONTRACTOR ON HOW TO PERFORM THE WORK. EVERY CONNECTION, CORNER, FLASHING, ETC. MUST BE RESOLVED. NOTIFY ARCHITECT IF A CONDITION NEEDS ADDITIONAL DIRECTION OR DETAIL. ARCHITECT IS NOT LIABLE FOR WORK THAT IS NOT DETAILED/SPECIFIED BY ARCHITECT. IF DRAWINGS HAVE A DETAILED SPECIFICATION FOR A CERTAIN PRODUCT , CONTRACTOR MAY REQUEST A SUBSTITUTION APPROVAL BY ARCHITECT . IF DRAWINGS HAVE A GENERIC SPECIFICATION CONTRACTOR IS FREE TO USE ANY PRODUCT THAT MEETS WHAT IS SPECIFIED WITHOUT APPROVAL BY ARCHITECT. 8. VERIFY SITE INFORMATION: 8.1. CONTRACTOR IS TO VERIFY ALL SITE INFORMATION AND ASSUMPTIONS, ESPECIALLY SUBTERRANEAN CONCEALED CONDITIONS INVOLVING HIDDEN UTILITIES AND SOIL CONDITIONS. SHOULD ANY CONDITIONS AFFECTING THE WORK BE DISCOVERED BY THE CONTRACTOR, HE IS TO NOTIFY THE ARCHITECT IMMEDIATELY. CONTRACTOR SHALL VERIFY THAT EXISTING SOILS MEET THE MINIMUM CAPACITY PER THE STRUCTURAL DESIGN. 9. PRIOR TO ANY EXCAVATION WORK : 9.1. THE CONTRACTOR IS REQUIRED TO LOCATE ANY AND ALL UTILITIES IN OR UNDER CONSTRUCTION, AND MAKE ARRANGEMENTS FOR THEIR LEGAL RE-ROUTING, AS ACCEPTABLE TO GOVERNING AGENCIES, AUTHORITIES, UTILITIES AND OWNER. CONTACT ALL AFFECTED UTILITY COMPANIES AND INFORM THEM OF THE IMPENDING CONSTRUCTION, AND OBTAIN THEIR ASSISTANCE IN LOCATING THEIR UTILITIES. 10. DIMENSIONS: 10.1. DIMENSIONS ON ARCHITECTURAL DRAWINGS MAY BE "ROUGH" OR "FINISH." SEE PLANS FOR REQUIREMENTS. ARCHITECTURAL DIMENSIONS SHALL TAKE PRECEDENCE OVER STRUCTURAL OR OTHER DIMENSIONS, IF NO OTHER CONFLICT RESULTS. DOCUMENT ANY SUCH DISCREPANCIES TO ARCHITECT IN WRITING. DO NOT RELY ON SCALED DIMENSIONS. NOTES TAKE PRECEDENCE OVER GRAPHICS. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS FOR WORK TO EXISITING BUILDINGS. 11. HEIGHT ELEVATIONS: 11.1. BUILDING HEIGHT ELEVATIONS TYPICALLY USE THE MAIN FLOOR SLAB AS ELEVATION 0'-0" (BUILDING ELEVATIONS MAY BE NOTED AS "BLDG EL. __" OR "EL. __" OR "AFF. __”) ANY ELEVATION NOT OTHERWISE DESIGNATED AS A SITE ELEVATION IS ON ANY PLANS OTHER THAN THE SITE PLAN IS ASSUMED TO BE A BUILDING ELEVATION. SITE ELEVATIONS MAY BE BASED ON THE SURVEY, WHICH MAY USE MEAN SEA LEVEL, NAVD, OR OTHER HEIGHT AS A REFERENCE DATUM. SITE ELEVATIONS MAY BE NOTED AS: "SEL __" OR "__ NAVD" OR " +X.X' ". CONSULT ARCHITECT FOR ANY QUESTIONABLE LOCATIONS PRIOR TO CONSTRUCTING. 12. AMBIGUITY: 12.1. IN THE EVENT OF ANY AMBIGUITY OR QUESTION WITH REGARD TO THE INTENT OF THE DOCUMENTS, THE ARCHITECT SHALL INTERPRET THE CONSTRUCTION DOCUMENTS. 12.2. IN CASE OF CONFLICTS BETWEEN ARCHITECTURAL AND STRUCTURAL DRAWINGS, CONSULT WITH ARCHITECT. IN CASE OF CONFLICT BETWEEN THE GENERAL NOTES, SPECIFICATIONS, AND DRAWINGS, CONSULT WITH ARCHITECT . 13. FLORIDA PRODUCT APPROVALS / SUBMITTALS / SHOP DRAWINGS: 13.1. THE SUBMISSION OF REQUIRED NOTICES OF ACCEPTANCE (NOA) / PRODUCT APPROVALS ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS REQUIRED TO MAKE THESE AVAILABLE AT TIME OF INSPECTION. EVEN IF THE ARCHITECT PROVIDES THESE THE CONTRACTOR MAY CHANGE TO A DIFFERENT PRODUCT THAT MEETS THE SAME OR HIGHER BUILDING DESIGN PRESSURES, SOME JURISDICTIONS WILL REQUIRE A REVISION. IF THERE IS A DISCREPANCY BETW THE FASTENING OF PRODUCTS, ACCORDING TO MFR INSTALLATION AND ARCHITECT'S SPECS, VERIFY W/ ARCHITECT. 13.2. SHOP DRAWINGS/SUBMITTALS WILL BE REVIEWED FOR DESIGN CONFORMITY AND GENERAL CONFORMANCE TO CONSTRUCTION DOCUMENTS ONLY. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT JOBSITE FOR TOLERANCE, CLEARANCE, QUANTITIES, FABRICATION PROCESSES /TECHNIQUES OF CONSTRUCTION, COORDINATION OF HIS WORK WITH OTHER TRADES, AND FULL COMPLIANCE WITH CONSTRUCTION DOCUMENTS. 14. GENERAL STRUCTURAL 14.1. ONCE SIGNED & SEALED BY ARCHITECT OR ENGINEER. DESIGN PROFESSIONAL CERTIFIES THAT THE CONSTRUCTION DOCUMENTS MEET THE LOAD REQUIREMENTS STATED IN THE APPLICABLE FBC REFERENCED. 14.2. THE CONTRACTOR IS RESPONSIBLE FOR ALL METHODS, PROCEDURES AND SEQUENCES OF CONSTRUCTION. PROVIDE APPROPRIATE SUPERVISION THROUGHOUT THE PROJECT. CONSTRUCTION SITE SAFETY, INCLUDING ALL ADEQUATE TEMPORARY BRACING AND SHORING, IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EMPLOY THE NECESSARY PROFESSIONAL SERVICES TO DETERMINE THE NECESSARY METHODS AND SUPPORTS REGARDING FORMING AND CONSTRUCTION LOADS. TEMPORARY BRACING AND SHORING SHALL BE DESIGNED TO RESIST ALL CONSTRUCTION LOADS INCLUDING THE WEIGHTS OF ALL SUPPORTED MATERIALS PLUS A LIVE LOAD OF 50 PSF ON HORIZONTAL SURFACES. MAINTAIN TEMPORARY BRACING AND RETAIN IN PLACE UNTIL PERMANENT STRUCTURAL SYSTEMS ARE CAPABLE OF RESISTING ALL CONSTRUCTION PHASE LOADS. 14.3. THE CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO FABRICATION AND START OF CONSTRUCTION. THE CONTRACTOR SHALL PROTECT AND MAINTAIN ALL CONSTRUCTION AND ITS CONTENTS. 14.4. SPECIFIC PRODUCT DATA MUST BE PROVIDED TO ARCHITECT FOR APPROVAL OF HEAVY FINISHES SUCH AS TILE ROOFS OR STONE ON RAISED FLOORS. 15. CAST-IN-PLACE CONCRETE 15.1. ARCHITECT OR ENGINEER OF RECORD TO BE NOTIFIED IN WRITING PRIOR TO POUR, TO GIVE ARCHITECT THE OPTION TO INSPECT THE REINFORCEMENT FOR OVERHEAD BEAMS AND SLABS 15.2. CONCRETE PROPORTIONING, PLACING, FINISHING AND CURING SHALL BE AS PER THE LATEST EDITION OF THE PCA MANUAL. LEAVE SUPPORT FOR ELEVATED CONCRETE IN PLACE UNTIL THE CONCRETE HAS REACHED ITS DESIGN STRENGTH: -FOOTINGS AND SLAB-ON-GRADE TO BE 3000 PSI CONCRETE MIN UNO 15.3. CONCRETE, WHEN PLACED, SHALL HAVE A SLUMP OF 6 INCHES MAXIMUM AND 1 INCH MINIMUM EXCEPT FOR SLABS ON-GRADE WHICH SHALL HAVE A MAXIMUM SLUMP OF 5 INCHES AND A MINIMUM OF 3 INCH. 15.4. COMPLY WITH ALL REQUIREMENTS OF ACI 117-10, ACI 318-14, ACI-315 15.5. ALL REINF SHALL CONFORM TO ASTM 615 FOR GRADE 60 STEEL; WELDED WIRE MESH TO ASTM A-185. ARRANGEMENT AND BENDING OF REINF STEEL SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE ACI DETAILING MANUAL AND THE CONCRETE REINF STEEL INSTITUTE . DON'T SPLICE IN MIDDLE 1/3 OF BEAM OR COLUMN SPAN, IF A SPLICE IN SPAN IS UNAVOIDABLE, FOLLOW DEVELOPMENT LENGTH/LAP DISTANCE IF NOT NOTED VERIFY W/ ARCHITECT 15.6. CHECK ALL DRAWINGS AND APPLICABLE MANUFACTURER'S SHOP DRAWINGS FOR LOCATION OF ALL EMBEDDED ITEMS SUCH AS PIPE SLEEVES, ANCHOR BOLTS, ETC., PRIOR TO PLACING CONCRETE. 15.7. PROTECT FRESHLY PLACED CONCRETE FROM PREMATURE DRYING AND EXCESSIVE COLD OR HOT TEMPERATURES. START INITIAL CURING AS SOON AS FREE WATER HAS DISAPPEARED FROM THE CONCRETE SURFACE AFTER PLACING AND FINISHING. KEEP CONTINUOUSLY MOIST FOR NOT LESS THAN 7 DAYS IN ACCORDANCE WITH ACI 301 PROCEDURES. PERFORM CURING OF THE CONCRETE BY CURING AND SEALING COMPOUND, BY MOIST CURING, BY MOISTURE RETAINING COVER CURING OR BY COMBINATION THEREOF. 15.8. SEE THE DRAWINGS FOR CONCRETE COVER FOR REINF STEEL, BUT IN NO CASE SHALL THE COVER BE LESS THAN THAT REQUIRED BY ACI318: -CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH; 3" -CONCRETE EXPOSED TO EARTH OR WEATHER: #5 BARS AND SMALLER, 1 1/2" INCHES; #6 BARS AND LARGER, 2" 15.9. CONCRETE SLAB ON GRADE CONTROL JOINTS SHALL BE AS SHOWN ON THE FOUNDATION PLAN OR TYPICAL DETAILS. WHERE CONTROL JOINTS ARE NOT SHOWN ON PLANS, ALL CONCRETE SLABS ON GRADE SHALL BE BOUND BY KEYED, DOWELED OR SAW-CUT CONTROL JOINTS SUCH THAT THE ENCLOSED AREA DOES NOT EXCEED 260 SQUARE FEET. POST-TENSIONED CONCRETE SLABS ON GRADE SHALL NOT HAVE CONTROL JOINTS UNLESS SPECIFICALLY NOTED ON THE PLANS. EXPANSION JOINT FILLER SHALL BE NON-EXTRUDED PREMOLDED MATERIAL OF ASPHALT IMPREGNATED FIBERBOARD (ASTM D1751) 15.10. CONSTRUCTION JOINTS OR POUR JOINTS IN STRUCTURAL ELEMENTS (BEAMS, COLUMNS, ELEVATED SLABS , ETC.) NOT SPECIFICALLY SHOWN OR NOTED ON THE DRAWINGS REQUIRE PRIOR APPROVAL OF THE ARCHITECT. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS SHOWING PROPOSED JOINTS TO ENGINEER FOR APPROVAL. 15.11. ALL CONCRETE SHALL UTILIZE A MINIMUM OF 20% FLY ASH CONTENT . 15.12. VERT AND HORIZ REINF SHALL BE PROVIDED AS SHOWN ON THE DRAWINGS. PLACE VERT REINF BARS AT CORNERS, JAMBS OF OPENINGS, BELOW BEAM BEARING, AND IN WALLS AS INDICATED ON THE DRAWINGS. VERT WALL REINF BARS SHALL EXTEND CONTINUOUS FROM FOUNDATION INTO TOP BOND BEAM. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PER ACI 318 OR FBC UNO. -TIES/STIRRUPS TO START AT A DISTANCE FROM SUPPORT OF 1/2 TIE SPACING 15.13. NO HOLES, CHASES, OR EMBEDMENT OF PIPES OTHER THAN THOSE SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE MADE IN CONCRETE MEMBERS WITHOUT ARCHITECT'S APPROVAL. 24. CONNECTORS/FASTENERS: 24.1. CONNECTORS BY SIMPSON OR APPROVED SIMILAR TO BE HDG OR ZMAX COATED IF UNEXPOSED TO WEATHER AND TO BE STAINLESS STEEL IF EXPOSED TO WEATHER UPON COMPLETION . 24.2. UPLIFT CONNECTORS MAY BE SUBSTITUTED WITH CONNECTORS WITH ≥ THE DOCUMENTED UPLIFT VALUE IS ≥ SPECIFIED CONNECTOR. UNLESS SPECIFIED UPLIFT CONNECTORS ARE NOT REQUIRED ON LOADBEARING WALLS THAT ARE NOT SUBJECT TO UPLIFT OR SHEAR. SPACE NAILS AT STRAPS AS TO NOT SPLIT WOOD, USE MINIMUM NAIL QTY REQUIRED BY MFR. IF MULTIPLE FASTENER OPTIONS USE EITHER UNLESS SPECIFIED BY ARCHITECT. 26. EXTERIOR DOORS AND WINDOWS: 26.1. INSTALL OVERHEAD DOORS (INCLUDING BUCKS), EXTERIOR DOORS, AND WINDOWS AS PER MFR'S SPECIFICATION/ PRODUCT APPROVAL. 26.2. PT 1x BUCK: ATTACH TO MASONRY /CONC W/ADHESIVE & RECESSED 3/16"x2" MIN TAPCON OR 6D CASE HARD NAILS OR T NAILS @ 12"/3" END. ATTACH TO MASONRY /CONC W/ADHESIVE & RECESSED 3/16"x2" MIN TAPCON OR 6D CASE HARD NAILS OR T NAILS @ 12"/4" END. PT 2x BUCK: ATTACH TO MASONRY /CONC W/ADHESIVE & RECESSED 1/4"x3 1/4" MIN TAPCON @ 12"/4" END. 26.3. MIN OVERHEAD DOOR BUCK: 2x6 @ SIDES TO FILLED CELL W/ WEDGE ANCHOR @ 24" OC MIN, 12" FROM ENDS. WEDGE ANCHOR TO BE 1/2" x 6" W/ 2" x 1/8" WASHER. 2x6 @ TOP TO LINTEL W/ 1/4" x 2.75" TAPCONS STAG @ 24" OC. 26.4. CONTRACTOR TO VERIFY THE FOLLOWING WITH MFR/SUPPLIER PRIOR TO CONSTRUCTION: -ROUGH OPENING DIMS, EGRESS COMPLIANCE (FBC R310), SAFETY GLASS COMPLIANCE (FBC R308.4) 26.5. CONTRACTOR TO FIELD VERIFY OPENINGS BEFORE ORDERING DOORS/WINDOWS. 26.6. DOORS BETWEEN GARAGE & RESIDENCE TO BE 20 MINUTE FIRE RATED OR 1-3/8" THICK SOLID WOOD AS PER FBC R 302.5.1. 26.7. FLASHING AS PER FBC R703.4 AND REFERENCED FMA/AAMA DOCUMENTS. 26.8. GLASS TO HAVE: LOW-E, U-FACTOR ≤ 0.4, SHGC ≤ 0.25 26.9. SIZES ARE NOMINAL AND CAN VERY +/- 2" IN SIZE IF EGRESS IS NOT EFFECTED. 27. ELECTRICAL & LIGHTING NOTES 27.1. PLANS ARE SCHEMATIC. EXACT LAYOUT/SIZING OF CIRCUITS, RECEPTACLES, FIXTURES, AND EQUIPMENT, SHALL BE DETERMINED BY AN ELECTRICAL CONTRACTOR. IF LAYOUT/SIZING IS PROVIDED ELECTRICAL CONTRACTOR TO VERIFY. 27.2. ALL 120V 15A AND 20A DWELLING UNIT RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT TYPE. 27.3. PROVIDE AFIC AS DETERMINED BY NEC 210.12 OR FBC R 3902. 27.4. PROVIDE GFIC AS DETERMINED BY NEC 210.8 OR FBC R 3902. 27.5. ALL EXTERIOR OUTLETS TO BE GFIC WITH WEATHER TIGHT PROTECTIVE COVER. 27.6. SMOKE ALARMS SHALL BE HARD WIRED, INTERCONNECTED, W/ BATTERY BACKUP PER FBC R314. 27.7. CARBON MONOXIDE ALARM TO BE INTEGRAL WITH SMOKE ALARM AND COMPLY WITH FBC R315. 27.8. PROVIDE POWER RECEPTACLE & LIGHT, WHEN ATTIC CONTAINS AHU OR HAS STORAGE AREA. 28. PLUMBING: 28.1. PLANS ARE SCHEMATIC. ACTUAL LOCATION, MATERIAL, AND SIZE OF PIPES, DRAINS, AND VENTS SHALL BE DETERMINED BY A LICENSED PLUMBER. IF LAYOUT/SIZING IS PROVIDED PLUMBING CONTRACTOR TO VERIFY. 28.2. SEPTIC & DRAIN FIELD IS SCHEMATIC, EXACT LAYOUT/SIZING SHALL BE BY A LICENSED SEPTIC CONTRACTOR AND ADHERE TO 64E-6, F.A.C. 28.3. NO PLUMBING REQUIREMENTS SHALL INTERRUPT THE STRUCTURAL INTEGRITY OF THE BUILDING. 31. FLAME SPREAD INDEX & SMOKE DEVELOPED INDEX: 31.1. FLAME SPREAD INDEX & SMOKE DEVELOPED INDEX: 31.2. FINISHES TO COMPLY WITH THE BELOW FIGURES AS PER FBC R302.9 - 302.10 31.3. INSULATION FLAME SPREAD: <25, INSULATION SMOKE DEVELOPED: <450 31.4. WALL/CLG FLAME SPREAD: <200, WALL/CLG SMOKE DEVELOPED: <450 32. CLIMATIC & GEOGRAPHIC DESIGN CRITERIA: 32.1. WEATHERING: NEGLIGIBLE, TERMITE AREA: VERY HEAVY 33. MISC: 33.1. ROOF SYSTEM & FLASHING AS PER MFR INSTRUCTIONS. 33.2. GUARDRAILS AS PER FBC R312. 33.3. STAIRWAY AS PER FBC R311.7. 33.4. MEP SYSTEMS 1'+ BFE, AS PER FBC R322.1.6. 33.5. MECHANICAL APPLIANCES TO BE PROTECTED IF INSTALLED ON FLOOR IN GARAGE AS PER M1307.3.1. USE 2" DIA x 36"H PIPE W/ COLLAR BASE, ATTACH COLLAR TO SLAB W/ (4) 1/4" x 2.25" TAPCON. 33.6. CAULK BOTTOM OF SOLE PLATE AT GARAGE COMMON FRAME WALL. 33.7. IGNITION BARRIER NOT REQUIRED FOR SPRAY FOAM IN ATTIC UNO. 33.8. PROVIDE FIRE BLOCKING AS PER FBC R 302.11. 33.9. PROVIDE DRAFT STOPPING IN THE FORM OF ½” PLY OR GWB TO FLOOR-CEILING ASSEMBLIES GREATER THAN 1,000SF AS PER FBC R302.12. 34. FINISHES: 34.1. GWB: MOISTURE RESISTANT GWB @ ALL WET AREAS, CEMENT BOARD INSIDE SHOWER COMPARTMENTS. USE 5/8” TYPE X GWB ON GARAGE CEILING IF CONDITIONED/HABITABLE AREA ABOVE . GARAGE SEPARATION WALL TO HAVE A MINIMUM OF ONE 1/2" LAYER OF GWB ON THE GARAGE SIDE OF WALL AS PER FBC R302.6. SEE DOOR GEN NOTE 26.6. 34.2. EXTERIOR LATH AS PER FBC R703.7.1/ASTM C1063-11A. FOR EXTERIOR CEILINGS/SOFFITS USE MIN. 5/8" STUCCO ON RIBBED LATH. ATTACH TO BOTTOM OF WOOD FRAMING W/ 11GA NAILS W/ 3/8" HEAD @ 6" OC W/ 1-3/4" EMBED INTO WOOD. TYP TRANSITION FROM WOOD TO CONC (I.E. @ GABLE END) TO HAVE A VINYL CONTROL JOINT IN STUCCO. 34.3. EXTERIOR T&G WOOD CEILING. ATTACH 1x4 OR 1x6 BOARD W/ 2" 16GA FINISH NAIL EA RAFTER /JOIST/BC. TO CHANGE ORIENTATION USE 2x4 FLAT PURLINS ATTACHED TO EA RAFTER /JOIST/BC W/ (2)16D NAIL. ABBREVIATIONS: AB ANCHOR BOLT A/C AIR CONDITIONER AHU AIR HANDLING UNIT AT ACOUSTICAL TILE B.M. BENCH MARK BM BEAM BC BOTTOM CHORD BLK BLOCK BO BY OWNER BOTT BOTTOM BP BOTTOM PLATE CJ CONTROL (CONSTRUCTION) JOINT CL CENTER LINE CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT CO CONNECTOR COL COLUMN CONC CONCRETE CONT CONTINUOUS CU CONDENSING UNIT OR COPPER CW COLD WATER CXN CONNECTION D NAIL SIZE (PENNY) DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DISP DISPOSAL DN DOWN DR DRYER DTL DETAIL DW DRIVEWAY 'E' EXISTING EA EACH EJ EXPANSION JOINT EL BUILDING ELEVATION ELECT ELECTRICAL ELEV ELEVATOR OR ELEVATION EW EACH WAY EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EXP EXPOSED EXT EXTERIOR EXTG EXISTING F1 FOOTING #1 FA FASTENER FD FIELD (FLOOR) DRAIN FE FIRE EXTINGUISHER FF FINISH FLOOR FIN FINISH FLR FLOOR FP FIRE PROTECTION EPS EXPANDED POLYSTYRENE FTG FOOTING FT FOOT (OR FEET) GALV GALVANIZED GFI GROUND FAULT INDICATOR GSF GROSS SQUARE FEET GWH GAS WATER HEATER GWB GYPSUM WALL BOARD HB HOSE BIB HC HOLLOW CORE HDG HOT DIPPED GALVANIZED HORIZ HORIZONTAL HW HOT WATER HWH HOT WATER HEATER IN INCH INT INTERIOR JT JOINT MAX MAXIMUM MEP MECH/ELECT/PLUMB MFR MANUFACTURER MIN MINIMUM MO MASONRY OPENING MW MICROWAVE NIC NOT IN CONTRACT NTS NOT TO SCALE NSF NET SQUARE FEET L-1 LINTEL #1 LF LINEAL FOOT OA OVERALL OC ON CENTER OAS OR APPROVED SIMILAR PL PROPERTY LINE OR PLATE PLY PLYWOOD PT PRESSURE TREATED PVC POLY VINYL CHLORIDE R RADIUS R/A RETURN AIR RCB REINFORCED CONCRETE BEAM RCC REINFORCED CONCRETE COLUMN RD ROOF DRAIN REF REFRIGERATOR REINF REINFORCING REQ REQUIRED R/W RIGHT-OF-WAY RTU ROOF TOP UNIT S. SIMPSON (MFR) SBS STYRENE BUTADIENE STYRENE SEL SITE ELEVATION SF SQUARE FOOT SIM SIMILAR SK SINK SOG SLAB ON GRADE SS STAINLESS STEEL STAG STAGGERED TBD TO BE DETERMINED TC TOP CHORD TME TO MATCH EXISTING TOB TOP OF BEAM TOB TOP OF COLUMN TOS TOP OF SLAB TP TOP PLATE TPO THERMO PLASTIC OLEFIN TYP TYPICAL UG UNDER GROUND UNO UNLESS NOTED OTHERWISE VB VAPOR BARRIER VERT VERTICAL VTR VENT THRU ROOF W/ WITH WA WASHER MACHINE WP WATER PROOF WD WOOD WWF WELDED WIRE FABRIC/MESH # POUND OR NUMBER 16. CONCRETE MASONRY: 16.1. CMU DESIGNED AND TO BE IN ACCORDANCE ACI 530-13/ASCE 5-13/TMS 402-13, "BUILDING CODE REQ FOR MASONRY STRUCTURES", "COMMENTARY ON BUILDING REQ FOR MASONRY STRUCTURES". 16.2. MASONRY STRENGTH (f'm DESIGN) UNO: -BLOCK STRENGTH = 1900, ASTM C90 -MORTAR STRENGTH = 1800, TYPE S -GROUT STRENGTH = 2000 16.3. GROUT SHALL HAVE A SLUMP OF 8 TO 11 INCHES, BE IN CONFORMANCE WITH ASTM C 476-02 AND ATTAIN A COMPRESSIVE STRENGTH OF 3000 PSI. GROUT SHALL CONFORM TO REQUIREMENTS OF FLBC STANDARDS. USE SUFFICIENT WATER FOR GROUT TO FLOW INTO ALL JOINTS OF THE MASONRY WITHOUT SEGREGATION. ALL CELLS IN CONCRETE BLOCKS CONTAINING REINF SHALL BE FILLED SOLID WITH GROUT. ALL MASONRY BELOW FINISHED FLOOR OR GRADE SHALL BE GROUTED SOLID. HOLD GROUT DOWN 1-1/2" BELOW TOP OF BLOCK AT GROUT LIFT JOINTS AND AT CONCRETE PLACED OVER MASONRY. 16.4. CONCRETE MASONRY UNITS SHALL BE PLUMB, TRUE TO LINE, WITH LEVEL COURSES ACCURATELY SPACED AND BUILT TO THE THICKNESS AND IN A RUNNING BOND AS INDICATED AND CONFORMING TO THE TOLERANCES SPECIFIED IN ACI 531.1 AND 530.1. 16.5. REINF BARS SHALL BE PLACED IN THE MIDDLE OF THE CELLS, UNLESS NOTED OTHERWISE, AND TIED OR OTHERWISE SECURELY SUPPORTED AT THE TOP AND BOTTOM TO ENSURE THAT THE BAR DOES NOT MOVE DURING GROUTING. 16.6. MORTAR DROPPINGS AND OTHER DEBRIS MUST BE KEPT OUT OF CELLS WHICH ARE TO BE GROUTED. 16.7. CONTROL JOINTS SHALL BE PROVIDED IN ACCORDANCE WITH THE LOCATIONS AND DETAILS SHOWN ON THE DRAWINGS. CONTROL JOINTS SHALL NOT EXTEND THROUGH THE TOP BOND BEAM COURSE. THE JOINTS ON BOTH SIDES OF THE WALL SHALL BE SEALED AND TOOLED SMOOTH. 16.8. WALL REINFORCEMENT : VERT AND HORIZ REINF SHALL BE PROVIDED AS SPECIFIED ON THE DRAWINGS. DESPITE IF SHOWN ON DRAWINGS- PLACE VERT REINF BARS AT CORNERS, EA CELL WITHIN 16" OF CORNER, JAMBS OF OPENINGS, EA CELL WITHIN 16" OF JAMBS FOR OPENINGS WIDER THAN 12', BELOW BEAM BEARING, BELOW GIRDER TRUSS BEARING, AND IN WALLS AS INDICATED ON THE DRAWINGS. IF NOT SPECIFIED IN TEXT ON DRAWINGS USE #5 @ 48” OC. WALL REINF BARS SHALL EXTEND CONTINUOUS FROM FOUNDATION INTO TOP BOND BEAM. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PER ACI 318 OR FBC UNO. 8" TOLERANCE ALLOWED FOR WALL REINF SPACING. SEE DOWEL NOTE 17.2 BELOW. 16.9. REINF MASONRY LINTELS SUCH AS CAST CRETE TO BE INSTALLED AS PER MFR INSTRUCTIONS . USE #6 BOTTOM FIELD BAR IN LIEU OF #5 FOR ALL OPENINGS WIDER THAN 12'. LINTELS TO HAVE 4” MINIMUM BEARING. CONTINUOUS REINF ACROSS COLUMNS. IF SPECIFIED, OA LINTEL LENGTH IS +/- AS LONG AS MIN BRG IS MET. DOOR/WINDOW LINTELS CAN BE DEEPER(TALLER) THAN SPECIFIED BUT NOT SHORTER. 16.10. UNO HORIZ JOINT REINF @ 16” OC IN MASONRY WALLS IS SUGGESTED BUT NOT REQUIRED TO CONTROL CRACKING. 16.11. BOND/TIE BEAMS/LINTELS- CONTINUE REINF BARS CONT (UNINTERRUPTED) AROUND ALL CORNERS, OVER OPENINGS, ACROSS WALL INTERSECTIONS , THROUGH TIE COLUMNS, AND UP/DOWN AT CHANGES IN BOND BEAM ELEVATION. 16.12. ALTERNATE WINDOW SILL: 4"H MIN x 8"W CAST CONC W/ (1) # 5 EXTENDED 4" INTO FILLED JAMB CELLS. 17. FOUNDATIONS: 17.1. BUILDING AREA TO BE STRIPPED/GRUBBED OF SURFACE DEBRIS/VEGITATION. FILL TO BE CLEAN GRANULAR & UNIFORMLY COMPACTED TO 95% DENSITY (ASTM D 1557) AND MEASURED IN 12" LIFTS. AT DISCRETION OF CONTRACTOR OR BLDG INSPECTOR, ARCHITECT RECOMENDS SOIL TO BE TESTED BY GEOTECH ENGINEER TO ENSURE MINIMUM SOIL BEARING PRESSURE CAPACITY & RECOMEND SITE PREP. 17.2. DOWEL VERT REINF BARS OUT OF THE FOUNDATION OR STRUCTURE BELOW WITH BARS OF THE SAME SIZE AND SPACING OF WALL ABOVE. THERE SHALL BE A DOWEL FOR EACH VERT REINF BAR. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PER ACI 318 OR FBC UNO. For #5: MINIMUM 30" LAP W/ 10" HOOK UNO. SEE WALL REINF NOTE 16.8 ABOVE. FOR MISSED EMBEDDED VERT DOWEL, EPOXY EMBED W/ 1/8" OVERSIZED HOLE DIA., 6" EMBED W/ CLEAN HOLE. 17.3. BUILDING SLABS-ON-GRADE TO BE REINF WITH 6x6 10/10 WWF MIN WITH MESH UP CHAIRS OVER 6-MIL MINIMUM POLYETHYLENE FILM VAPOR RETARDER OVER TERMITE TREATED COMPACTED GRADE UNO. SUGGESTION TO PROVIDE DIAGONAL 36" #4 REBAR AT ALL INSIDE 'REENTRANT' CORNERS. 17.4. CONTINUOUS FOOTINGS, STEM OR MONOLITHIC, TO BE REINF CONTINUOUS, WITH LAPS AS PER STATED DEVELOPMENT LENGTH IF NOTED OR 48x BAR DIAMETER MIN UNO. 30" MIN CORNERS BARS TO MATCH LONGITUDINAL REBAR. 17.5. SUGGESTION TO PROVIDE A 4-INCH MEDIUM TO COARSE SAND OR GRAVEL COMPACTED DRAINAGE FILL BELOW ALL INTERIOR SLABS-ON-GRADE. 17.6. SOIL AND SUBGRADE IS TO BE TERMITE TREATED. 17.7. SLAB FINISHES UNO: -MAIN BUILDING: STEEL TROWEL FINISH -GARAGE: STEEL TROWEL, THRESHOLD: LIGHT BROOM -DRIVEWAY, DRIVEWAY APRON , PORCHES/PATIOS: LIGHT BROOM 17.8. GARAGE, AND ALL EXTERIOR HARD SURFACES TO SLOPE AWAY FROM BLDG MIN 1/8"/FT. 17.9. CONCRETE PADS FOR VIBRATING EQUIPMENT SUCH AS PUMPS OR MOTORS TO BE SEPARATED FROM HOUSE SLAB WITH A MINIMUM OF AN ASPHALT EXPANSION JOINT. 17.10. RECESS SGD & GARAGE DOOR THRESHOLDS 3/4"- VERIFY EXACT DIMENSIONS WITH SUPPLIER/MFR. 17.11. COLUMN/WALL AND FOOTING CENTERLINES SHALL COINCIDE UNLESS DIMENSIONED OTHERWISE. 17.12. SLOPE GRADES AWAY FROM BUILDING ON ALL SIDES A MINIMUM OF 6" OVER 10', 4:1 SLOPE MAX. 19. LIGHT GAGE METAL STUDS & MISC. METAL FRAMING : 19.1. ALL LIGHT GAGE METAL INTERIOR STUDS SHALL BE G90 GALVANIZED 25 GA MINIMUM. USE 20 GA STUDS WHERE HEAVY LOADS ARE HUNG FROM SUCH AS TV'S OR WALL CABINETS . ALL WALL TRACKS SHALL BE 25 GA. 20. HVAC: 20.1. PLANS ARE SCHEMATIC. EXACT LAYOUT/SIZING OF UNITS, DUCTS, RETURN AIR GRILLES AND SUPPLY GRILLES ETC, SHALL BE DETERMINED BY A HVAC LICENSED CONTRACTOR . IF LAYOUT/SIZING IS PROVIDED HVAC CONTRACTOR TO VERIFY. 20.2. PROVIDE MANUFACTURED CONCRETE PAD AND BRACKETS RATED FOR SPECIFIED WIND LOAD FOR CONDENSING UNIT. FOR MOUNTING AND SECURING MECHANICAL EQUIPMENT, REFER TO THE MANUFACTURER'S SPECIFICATIONS. 21. WOOD FRAMING 21.1. ALL STRUCTURAL (LOAD BEARING) LUMBER SHALL BE S.Y.P. OR DOUGLASS FIR, GRADE #2, KD 19% (Fb FOR LUMBER SIZES NOTED TO BE IN CONFORMANCE WITH VALUES LISTED IN THE NATIONAL FOREST PRODUCTS ASSOCIATION NATIONAL DESIGN STANDARD SUPPLEMENT TABLE 4B), AND SHALL CONFORM TO THE NATIONAL GRADING RULE FOR DIMENSION LUMBER, THE SOUTHERN PINE INSPECTION BUREAU AND THE SOUTHERN FOREST PRODUCTS ASSOCIATION. ALL NON-LOAD BEARING FRAMING LUMBER (INTERIOR WALLS) TO BE #2 S.P.F. OR BETTER. 21.2. ALL WOOD MEMBERS IN CONTACT WITH CONCRETE AND/OR MASONRY TO BE PRESSURE TREATED. ALL WOOD EXPOSED TO THE WEATHER OR IN CONTACT WITH THE GROUND TO BE PRESSURE TREATED TO 0.80 CCA. 21.3. SPLICING FOR MULTI-PLY HEADERS /BEAMS/COLUMNS: -2x4- 10d COMMON NAIL @ 6" OC EACH LAYER STAGGERED. -2x6- 2 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. -2x8- 3 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. -2x10- 4 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. -2x12- 5 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. -LOCATE SPLICES OVER BRG SUPPORTS. GLUE BETW LAYERS. USE 16D IF 1/2" PLY SPACER USED 21.4. LAMINATED TIMBER ELEMENTS (BENTS, BEAMS, DECK, ETC., AND ANCILLARY ACCESSORIES, FASTENERS, ETC.: -FABRICATOR TO SUBMIT SHOP DRAWINGS AND CALCULATIONS FOR ALL ELEMENTS OVER SIGNATURE AND SEAL OF FLORIDA ENGINEER (SPECIALTY ENGINEER ) -SPECIALTY ENGINEER MAY SUBMIT CONNECTION DETAILS FOR BENTS AND BEAMS AND FASTENING MODE AND INTERVALS FOR DECK. (CONNECTIONS FOR BEAM-ENDS TO RESIST ROTATION.) 21.5. GLUE-LAMINATED BEAMS (GLULAM) SHALL BE DOUGLAS FIR COMBINATION 24F-V4 AT SIMPLE SPANS AND 24F-V8 AT CANTILEVER SPANS HAVING THE FOLLOWING MINIMUM PROPERTIES: Fb = 2,400 PSI, Fv = 190 PSI, Fc (PERPENDICULAR) = 650 PSI, E = 1,800,000 PSI, FABRICATION AND HANDLING SHALL CONFORM TO THE LATEST AMERICAN INSTITUTE FOR TIMBER CONSTRUCTION (AITC) AND ASTM STANDARDS. BEAMS SHALL BEAR AN APPROPRIATE GRADE STAMP CLEARLY NOTING ITS DESIGN PROPERTIES. UNLESS CAMBER AND TOLERANCE IS SPECIFICALLY NOTED ON THE DRAWINGS, BEAMS SHALL BE MANUFACTURED WITH INDUSTRY STANDARD MINIMUM CAMBER OR UPWARD TO SPAN/200. ERECT WITH CROWN OR CAMBER UP. IN HEADER CONDITIONS (BEAM BUILT INTO WALL) CRIPPLE FRAMING ABOVE HEADER SHALL MAINTAIN CAMBER. HEADER BEAMS MAY HAVE ZERO CAMBER, PROVIDED CRIPPLE FRAMING ABOVE HEADER IS BUILT WITH MINIMUM CAMBER STATED ABOVE. 21.6. LAMINATED LUMBER AND "I" JOISTS AND RAFTERS SHALL BE INSTALLED AS PER MANUFACTURER'S INSTRUCTIONS. 21.7. END STUDS OF EXTERIOR FRAME WALL OR DESIGNATED INTERIOR SHEAR WALLS TO ATTACH TO CONC WALL W/ .25” x 3.25” TAPCON @ 16” OC/8" ENDS. FOR INTERIOR BRG WALLS USE 1/4" x 2.75" TAPCON @ 32" OC/8" ENDS. 21.8. ALL WOOD NAILING AS PER FBC R 602.3 UNO. 22. PLYWOOD SHEATHING: 22.1. ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING. INSTALL PLYWOOD WITH FACE GRAIN PERPENDICULAR TO SUPPORTS, PROVIDE BLOCKING AT PANEL EDGES WHERE INDICATED ON THE PLANS. 22.2. UPPER PANELS TO BE ATTACHED TO THE TOP MEMBER OF THE UPPER DOUBLE TOP PLATE AND TO RIM JOIST AT BOTTOM OF WALL. PROVIDE BLOCKING FOR ALL EDGE NAILING OVER LENGTH OF PLYWOOD 22.3. FOR EXTERIOR WALLS AND INTERIOR SHEAR WALLS USE 1/2" PLYWOOD AND 8d RINGSHANK GALV NAILS. SPACE NAILS 6" FIELD, 6" EDGE. 22.4. FOR ROOF USE 5/8" PLYWOOD AND 8d RINGSHANK GALV NAILS. SPACE NAILS 6" FIELD, 6" EDGE, 4" EDGE WITHIN 4' OF EAVES/RIDGES/GABLES. 22.5. FOR SUBFLOOR USE 3/4" PLYWOOD AND 2.5" #8 SCREWS & GLUE OR 8d RINGSHANK GALV NAILS & GLUE. SPACE FASTENERS 6" FIELD, 6" EDGE. 22.6. FOR ATTIC FLOOR USE 5/8" PLYWOOD AND 6d RINGSHANK GALV NAILS. SPACE NAILS 12" FIELD, 12" EDGE. ONLY ALLOWED WHERE TRUSS ENGINEERING SPECIFIES. SOIL BEARING: 2500 psf (assumed) WIND: 160mph (ult), risk cat 2, exp D, wind borne debri region, .18 enclosed design FROST DEPTH: 12" - THE STRUCTURAL DESIGN APPROACH FOR MASONRY, ROLLED STEEL, AND LIGHT WEIGHT STEEL IS WORKING STRESS DESIGN. THE DESIGN APPROACH FOR REINFORCED CONCRETE IS ULTIMATE STRENGTH DESIGN. THE DESIGN SERVICE LOADS ARE AS FOLLOWS: ROOF LIVE LOAD 20 PSF ROOF DEAD LOAD 10 PSF TC ROOF WIND LOAD (SEE DRAWINGS) CEILING DEAD LOAD 10 PSF BC WALL WIND LOADS (SEE DRAWINGS) FLOOR DEAD LOADS 15 PSF TC, 5 PSF BC FLOOR LIVE LOADS SEE BELOW FLOOR LIVE LOADS: Uninhabitable attics without storage 10 psf Uninhabitable attics with limited storage 20 psf Habitable attics and attics served with fixed stairs 30 psf Balconies (exterior) and decks 40 psf Fire escapes 40 psf Guardrails and handrails 200 lb Guardrail in-fill components 50 plf Passenger vehicle garages 50 psf Rooms other than sleeping room 40 psf Sleeping rooms 30 psf Stairs 40 psf