Loading...
HomeMy WebLinkAboutenergy_COOPER-ENERGY CALCEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 49/24/2020 8:59 AM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST. LUCIE COUNTY KENNETH COOPER KENNETH COOPER Street: City, State, Zip: FT. PIERCE , FL , 6740 N HWY A1A Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) Addition Single-family 1 No 863 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=1.05 144.00 ft² SHGC=0.25 N/A f t ² N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 863.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Ext Insul, Exterior R=4.1 765.00 ft² b. N/A R=f t ² c. N/A R=f t ² 10. Ceiling Types a. Roof Deck (Unvented)R=30.0 863.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts 12. Cooling systems 13. Heating systems 14. Hot water systems a . Cap: N/A b. Conservation features d. N/A R=f t ² Area Weighted Average Overhang Depth:2.000 ft. Area Weighted Average SHGC:0.250 Description Area Insulation Area Insulation Area Insulation Area 15. Credits Pstat - None required (Bedrms In Addition) 0(0) (144.0 sqft.) (765.0 sqft.) (863.0 sqft.) (863.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Heat Pump k B t u / h r 22.4 SEER:18.00 Efficiency k B t u / h r Efficiency 22.4 HSPF:9.00 f t ² R EF: 0.000 Glass/Floor Area: 0.167 Total Proposed Modified Loads: Total Baseline Loads: 19.72 26.48 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 9-24-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST. LUCIE COUNTY 1 KENNETH COOPER KENNETH COOPER Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle: 0 No 1 863 0 Addition Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , FT. PIERCE , St. Lucie 6740 N HWY A1A Street Address Comment: Building Type: User Cross Ventilation: No Whole House Fan: No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 863 7767 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 GAMEROOM 1 863 7767 No Yes Yes1 Yes # Floor Type Area Tile Wood Carpet FLOORS R-ValueSpace Perimeter 1 863 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -085 ft GAMEROOM 1 # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Flat Composition shingles 866 ft² Medium 0.6 30 4.8______ No36 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 No attic Unvented 863 ft² N N0 # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented) 0 863 ft² 0.11 Wood______ GAMEROOM 1 Blown 9/24/2020 8:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS # Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0G A M E R O O M 00025 9N Concrete Block - Ext Insul 0.60Exterior 225.0 ft² ____ 2 4.1 0G A M E R O O M 00025 9S Concrete Block - Ext Insul 0.60Exterior 225.0 ft² ____ 3 4.1 0G A M E R O O M 00035 9W Concrete Block - Ext Insul 0.60Exterior 315.0 ft² ____ # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 W Low-E Single 1.05 0.25 48.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes3 N 2 W Low-E Single 1.05 0.25 48.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes3 N 3 W Low-E Single 1.05 0.25 48.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes3 N Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 647.3 535.53.000286Wholehouse .103966.83Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtype BlockSpeed 1 Electric Heat Pump/Existing/co HSPF:9 22.4 kBtu/hr ______ DuctlessSplit 1 Single # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtype BlockSubtype 1 Central Unit/Existing/confirmed SEER: 18 22.4 kBtu/hr c f m 0.7______ DuctlessSplit 1 Single FSEC Company Name System Model # Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert # Area Volume f t ² ______ 9/24/2020 8:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078 Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 GAMEROOM 1 9/24/2020 8:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT