HomeMy WebLinkAboutenergy_COOPER-ENERGY CALCEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 49/24/2020 8:59 AM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction:
ST. LUCIE COUNTY
KENNETH COOPER
KENNETH COOPER
Street:
City, State, Zip: FT. PIERCE , FL ,
6740 N HWY A1A
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
Addition
Single-family
1
No
863
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=1.05 144.00 ft²
SHGC=0.25
N/A f t ²
N/A f t ²
N/A f t ²
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 863.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Concrete Block - Ext Insul, Exterior R=4.1 765.00 ft²
b. N/A R=f t ²
c. N/A R=f t ²
10. Ceiling Types
a. Roof Deck (Unvented)R=30.0 863.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
12. Cooling systems
13. Heating systems
14. Hot water systems
a . Cap: N/A
b. Conservation features
d. N/A R=f t ²
Area Weighted Average Overhang Depth:2.000 ft.
Area Weighted Average SHGC:0.250
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits Pstat
- None required
(Bedrms In Addition) 0(0)
(144.0 sqft.)
(765.0 sqft.)
(863.0 sqft.)
(863.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Heat Pump
k B t u / h r
22.4 SEER:18.00
Efficiency
k B t u / h r Efficiency
22.4 HSPF:9.00
f t ² R
EF: 0.000
Glass/Floor Area: 0.167
Total Proposed Modified Loads:
Total Baseline Loads:
19.72
26.48 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
9-24-2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
ST. LUCIE COUNTY
1
KENNETH COOPER
KENNETH COOPER
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle: 0
No
1
863
0
Addition
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
FT. PIERCE ,
St. Lucie
6740 N HWY A1A
Street Address
Comment:
Building Type: User
Cross Ventilation: No
Whole House Fan: No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 863 7767
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 GAMEROOM 1 863 7767 No Yes Yes1 Yes
# Floor Type Area Tile Wood Carpet
FLOORS
R-ValueSpace Perimeter
1 863 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -085 ft GAMEROOM 1
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Flat Composition shingles 866 ft² Medium 0.6 30 4.8______ No36 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 No attic Unvented 863 ft² N N0
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented) 0 863 ft² 0.11 Wood______ GAMEROOM 1 Blown
9/24/2020 8:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0G A M E R O O M 00025 9N Concrete Block - Ext Insul 0.60Exterior 225.0 ft² ____
2 4.1 0G A M E R O O M 00025 9S Concrete Block - Ext Insul 0.60Exterior 225.0 ft² ____
3 4.1 0G A M E R O O M 00035 9W Concrete Block - Ext Insul 0.60Exterior 315.0 ft² ____
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 W Low-E Single 1.05 0.25 48.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes3 N
2 W Low-E Single 1.05 0.25 48.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes3 N
3 W Low-E Single 1.05 0.25 48.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes3 N
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
647.3 535.53.000286Wholehouse .103966.83Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtype BlockSpeed
1 Electric Heat Pump/Existing/co HSPF:9 22.4 kBtu/hr ______ DuctlessSplit 1 Single
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtype BlockSubtype
1 Central Unit/Existing/confirmed SEER: 18 22.4 kBtu/hr c f m 0.7______ DuctlessSplit 1 Single
FSEC
Company Name System Model # Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert # Area Volume
f t ² ______
9/24/2020 8:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: Y Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078
Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878
Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 GAMEROOM 1
9/24/2020 8:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT