Loading...
HomeMy WebLinkAboutEnergy Codei• Whole Building Performance Method for Commercial Buildings Form 40OA 97 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs FLA/COM-97 Version 2.2 PROJECT NAME -MARTIN FOWLER PERMITTING OFFICE: ADDRESS: COMMERCE PARK BLVD.& RESERV _ST. LUCIE COUNTY .ST. LUCIE CTY., FL. CLIMATE ZONE: _6 OWNER: _MARTIN FOWLER PERMIT NO: AGENT: JURISDICTION NO: 661000 BUILDING TYPE: Mercantile (Retail) 'CONSTRUCTION CONDITION: New construction DESIGN COMPLETION: _Finished Building CONDITIONED FLOOR AREA: _3080 NUMBER OF ZONES: 3 MAX. TONNAGE OF EQUIPMENT PER SYSTEM: 6 COMPLIANCE CALCULATION: METHOD A DESIGN CRITERIA RESULT ----------------- -------------- ------ A. WHOLE BUILDING 56.59 100.00 PASSES PRESCRIPTIVE REQUIREMENTS: LIGHTING EXTERIOR LIGHTING 400.00 1088.00 PASSES LIGHTING CONTROL REQUIREMENTS PASSES HVAC EQUIPMENT COOLING EQUIPMENT 1. EER 8.90 8.90 PASSES IPLV 8.30 8.30 PASSES 2. SEER 12.05 10.00 PASSES 3. EER 8.90 8.90 PASSES IPLV 8.30 8.30 PASSES . HEATING EQIUIPMENT 1. Et 20.00 N/A 2. Et 20.00 N/A 3. Et 20.00 N/A AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS 1. Conditioned Space 6.00 0.00 N/A 2. Conditioned Space 6.00 0.00 N/A 3. Conditioned Space 6.00 0.00 N/A REHEAT SYSTEM TYPES USED NO REHEAT SYSTEM is USED WATER HEATING EQUIPMENT ! 1. EF 20.00 0.89 PASSES _ PIPING INSULATION REQUIREMENTS 1. Non -Circulating 2.00 0.60 PASSES ---------------------------------------------------------------------------- COMPLIANCE CERTIFICATION: I hereby certify that the plans and Review of the plans and specifica- specifications covered by this calcu- tions covered by this calculation lation are in compliance -with the indicates compliance with the F'lorid'a Energy ficien Co PREPARED BY: DATE: e! --o/ I hereby'certify that this building is in compliance with the Florida Energy Efficiency Code. OWNER/AGENT: DATE: I hereby certify(*) that the system design _Energy Efficiency.Code. SYSTEM DESIGNER Florida Energy Efficiency Code. Before construction is completed, this building will be inspected for compliance in accordance with Section 553.908, Florida Statutes. BUILDING OFFICIAL:�Zp DATE: ST• �DFDRCoI T ON3O0 RE VXD BY BE i�r c gib S e' Florida 1,�5 A~ ��EECTIOI� QgSTRATION/STATE ARCHITECT MECHANICAL: William Duffey #24433 Florida 'PLUMBING William Duffey #24433 Florida ELECTRICAL: William Duffey #24433 Florida LIGHTING . '(*) Signature is required where Florida law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. BUILDING ENVELOPE SYSTEMS COMPLIANCE CHECK 401.-- ---- GLAZING --ZONE' 1------------------------------------------------ v- Elevatioh Type U SC VLT Shading Area(Sgft) ---- 4.------------------ ---- ---- ---- -------------- ---------- Southeast Commercial 1.31 .94 .88 Continuous Ove 12111 Southeast Commercial 1.31 .94 .88 Continuous Ove 8311 Southeast Commercial 1.31 .94 .88 Continuous Ove 9 Total Glass Area in Zone 1 = 213; 401.------GLAZING--ZONE 2------------------------------------------------ v- Elevation Type U SC VLT Shading Area(Sgft); ------------------------ ---- ---- ---- -------------- ---------- Northwest Commercial 1.31 .94 .88 None oil Total Glass Area in Zone 2 = oil '401.------GLAZING--ZONE 3------------------------------------------------ v Elevation Type U SC VLT Shading Area(Sgft) ------------------------ ---- ---- ---- -------------- ---------- +Southwest Commercial 1.31 .94 .88 None oil Total Glass Area in Zone 3 = 0; Total Glass Area = 21311 402------ =WALLS --ZONE 1------------------------------------------------ 1 --- Elevation Type U Insul R Gross(Sgft); ----------------------------------------- ----- ------- ---------- Northwest cbs/siding/1/2"dw .194 4 1041 Southwest cbs/siding/l/2"dw .194 4 550 Southeast cbs/siding/l/2"dw .194 4 958 Total Wall Area in Zone 1 = 1612 402. -----WALLS--ZONE 2------------------------------------------------ ;--- Elevation Type U Insul R Gross(Sgft) ----------------------------------------- ----- ------- ----------- Northeast interior wall 0 0 135611 Total Wall Area in Zone 2 = 1356; 402. -----WALLS--ZONE 3------------------------------------------------;--- Elevation Type U Insul R Gross(Sgft) -,---------------------------------------- ----- ------- ----------- Northwest cbs/siding/l/2"dw .194 4 399 Northeast cbs/siding/l/2"dw .194 4 555 Southeast cbs/siding/l/2"dw .194 4 150; Total Wall Area in Zone 3 = 110311 Total Gross Wall Area = 4071 403.------DOORS--ZONE 1------------------------------------------------ 1--- Elevation Type U Area(Sgft) ----------------------------------------------=---- ---------------� Southeast 2 DOUBLE GLASS 1.03 42 Southwest 1-3/4 Steel Door -Solid Urethane foam co 0.40 21 Total Door Area in Zone 1 = 63 403.------DOORS--ZONE 2------------------------------------------------ 1--- Elevation Type U Area(Sgft) --------------------------------------------------- ----- ---------- No doors 0.00 oil Total Door Area.in Zone 2 = oil 403.. -----DOORS--ZONE 3------------------------------------------------; -- Elevation Type U Area(Sgft) -------------------------------------------------- ----- --------- Northwest 1-3/4 Steel Door -Solid Urethane foam co 0.40 21 Total Door Area in Zone 3 = 2111 Total Door.Area = 84 4D4.- ----ROOFS--ZONE 1------------------------------------- V---------- ;--- Type Color U Insul R Area(Sgft) - - - - - M- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3"wood/2"insul/st. seam ' Medium .073 10 1476 Total Roof Area in Zone 1 = 147611 404.-3----ROOFS--ZONE 2------------------------------------------------ ;--- Type • Color U Insul R Area(Sgft) ------------------------------------ ------ ---------------------- 3"wood/2"insul/st. seam Medium .073 10 72811 Total Roof Area in Zone 2 = 728; 404.------ROOFS--ZONE 3------------------------------------------------ ;--- Type Color U Insul R Area(Sgft) ------------------------------------ -- --- ---------------------- 3"wood/2"INSUL/ST. SEAM/CEILING Medium .028 32 66911 Total Roof Area in Zone 3 = 669; Total Roof Area = 2873; 405.- -----FLOORS-ZONE 1------------------------------------------------;--- TypeInsul R Area(Sgft) ----------------------------------------------------------------- Slab on Grade/Uninsulated 0 1476 Total Floor Area in Zone 1 = 1476 405.------FLOORS-ZONE 2-------------------------------------------------- ;--- Type Insul R Area(Sgft); ----------------------------------------------------------------- Slab on Grade/Uninsulated 0 72811 Total Floor Area in Zone 2 = 728; 405.------FLOORS-ZONE 3------------------------------------------------ ;--- Type Insul R Area(Sgft) -----------------------------------------------------------------; Floor over Unconditioned Space/Uninsulated 0 669; Total Floor Area in Zone 3 = 669; Total Floor Area = 2873; 406.------INFILTRATION -------------------------------------------------- ;--- CHECK Infiltration Criteria in 406.1.ABCD have been met. MECHANICAL SYSTEMS CHECK :-----------------------------------------------------------------;---- ;--- HVAC load sizing has been performed. (407.1.ABCD) 407.------COOLING SYSTEMS ----------------------------------------------- Type No Efficiency IPLV Tons; ---------------------------- ------------- ------------------- 1.. Air Cooled ( >= 65,000 Btu/h 1 8.9 0 6.31; 2. Split System 1 12.05 0 3.44 3. Air Cooled ('>= 65,000 Btu/h 1 8.9 0 6.30 408.------HEATING SYSTEMS ----------------------------------------------- ; --- Type No Efficiency BTU/hr -------------------------------- --------------------------- 1.. Electric Resistance 1 20 30000; �2."Electric Resistance 1 20 3000011 3, Electric Resistance 1 20 30000 409.------VENTILATION ---------------------------------------------------- ;--- CHECK Ventilation Criteria in 409.1.ABCD have been met. 410.-----AIR DISTRIBUTION SYSTEM----------------------------------------!--- CHECK; ------------------------------------------------------------------;-----i--- Duct sizing and design have been performed. (410.1.ABCD) AHU Type Duct Location R-value; -..-------------------------------------------------------------- 1. Air Conditioners Conditioned Space 6 2, Air Conditioners` Conditioned Space 6 3. Atr Conditioners Conditioned Space 6 CHECK; ------------------------------------------------------------------;-----;--- Testing and balancing will be performed. (410.1.ABCD) 411.-----PUMPS AND PIPING -ZONE -----------------------------------------'--- Basic prescriptive requirements in 411.1.ABCD have been met. 11 PLUMBING SYSTEMS 411.-----PUMPS AND PIPING -ZONE 1--------------------------------------- 1--- I . Type R-value/in Diameter Thickness; ---------------------------------------------------� 411.-----PUMPS AND PIPING -ZONE 2-------------------------------------- • Type R-value/in Diameter Thickness; --------------------------------------------------- 411. ----PUMPS AND PIPING -ZONE 3_______________________________________�___ Type R-value/in Diameter Thickness; --------------------------------------------------- 1. Non -Circulating 6 .75 2 412.-----WATER HEATING SYSTEMS -ZONE 1---------------------------------1--_ Type Efficiency StandbyLoss InputRate Gallons; ---------------------------------------------------------------- 412.-----WATER HEATING SYSTEMS -ZONE 2__________________________________I___ Type Efficiency StandbyLoss InputRate Gallons; ------------------------ ---------- ------ -----------------------� 412.-----WATER HEATING SYSTEMS -ZONE 3----------------------------------1--- I Type Efficiency StandbyLoss InputRate Gallons; --------------------------------------------------------------- �1. <=12 kW 20 0 9000 30 ELECTRICAL SYSTEMS CHECK; 413.-----ELECTRICAL POWER DISTRIBUTION ----------------------------- Metering criteria in 413.1.ABCD have been met. 414. ----MOTORS-------------------------------------------------- ; ----;--- Motor efficiencies in 414.1.ABCD have been met. 4f5.-----LIGHTING SYSTEMS -ZONE 1-------------------------------------- '--- _ 1 Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) ---------- ----------------- ---------------- --- ------ ---------- Type D(Gen 1 On/Off 2 960 118011 Accounting 2 On/Off 2 192 131 Material H 1 On/Off 2 1440 3301, Total Watts for Zone 1 = 259211 Total Area for Zone 1 = 1641 415. ----LIGHTING SYSTEMS -ZONE 2 --------------------------------------- Spa7ce Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) ---------- ----------------- ----------------- --- ----------------� Type D(Gen 1 On/Off 2 960 728 Total Watts for Zone 2 = 96011 Total Area for Zone 2 = 72811 415.-----LIGHTING SYSTEMS -ZONE 3--------------------------------------- 1-__ Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) ---------- ----------------- ----------------- --- ---------------- Kitchen 1 On/Off 1 On/Off 1 416 495 Toilet and 1 On/Off 2 On/Off 0 128 165 t. Total Watts for Zone 3 544 Total Area for Zone 3 = 660 Total Watts = 409611 r Total Area - 3029 ;CHECK; Lighting criteria in 415.1.ABCD have been met. ------------------------------------------------------------------; --- ;--- 16. Operation/maintenance manual will be provided to owner.(102.1) ----------------------------------------------------------------------------