HomeMy WebLinkAboutProduct Control Notice of Acceptance; FG-2000 Aluminium Storefront Systemr MIAMI-DADE MIAMI-DADE COUNTY. FLORIDA METRO-DADE FLAGLER BUILDING x BUILDING CODE COMPLIANCE OFFICE 4 METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 • PRODUCT CONTROL NOTICE OF ACCEPTANCE MIAMI. FLORIDA 33130-I563 (305) 375-2901 FAX (305) 375-2908 Vistawall Architectural Products CONTRACTOR LICENSING SECTION 803 Airport Road (305) 375-2527 FAX (305) 375-2558 Terrell TX' 7�160 CONTRACTOR ENFORCEMENT SECTION (305) 375-2966 FAX (305) 375-2908 PRODUCT CONTROL DIVISION Your application for Product Approval of: (305) 375-2902 FAx (305) 372-6339 FG-2000 Aluminum Storefront System. under Chapter 8 of the Code of Miami -Dade County governing the use of Alternate Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This approval shall not be valid after the expiration date stated below. BCCO reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of such product or material immediately. BCCO reserves the right to revoke this approval, if it is determined BCCO that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.: 00-0124.02 Expires:10/02/2003 Raul Rodriguez Chief Product Control Division THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE This application for Product Approval has been reviewed by the BCCO and approved by the Building Code and Product Review Committee to be used in Dade County, Florida under the conditions set forth above. rancisco 1. Quintana, R.A. Director 1 of 3 COUNTTY B , T affiP "" ounty Approved:05/26/2000 ST•LUCIE C L ng Codetompliance Oftic .0'MNNED FOR .. gEVIE�VED B _ TBE APT ON 1011 DATE 1,LANS AND PEWN'11T WILL BE MADE- ORNO i1VSPECT10�3 Internet mail address: postmaster@buildingeodeonline.com Homepage: http://www.buildingcodeon'line.com s Vistawall Architectural Products ACCEPTANCE No.: 00-0124.02 APPROVED _ MAY 2 6 2000 EXPIRES : October 2.2003 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 1. SCOPE 1.1 This renews the Notice of Acceptance No. 96-1023.01, which was issued on October 2, 1997. It approves an aluminum flush glazed storefront system,as described in Section 2 of this Notice of Acceptance, designed to comply with the South Florida Building Code, 1994 Edition for Miami - Dade County, for the locations where the pressure requirements, as determined by SFBC Chapter 23, do not exceed the Design Pressure Rating values indicated in the approved drawings. 2: PRODUCT DESCRIPTION 2.1 The, Series. Fg-2000' Aluminum Flush Glazed Storefront System and its components shall be constructed: in strict compliance with the following documents: Drawing No. FG-2000, titled "FG 2000 For. Dade, County, Florida," prepared by Robert E. Fisher & WM M. Meyers; P.E., sheets 1 thru 3 of 3, dated on June 25, 1997, revised. on April 5,. 2000,prepared by manufacturer, bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and approval. date by the Miami -Dade County Product Control Division. These documents shall hereinafter be referred to as the approved drawings. 3. LIIVIITATIONS' 3.1 This approval applies to. single unit applications and multiple lites applications, as. long as panel size does. not exceed the one tested and intermediate mullions -are used between all panels, as shown in the- approved drawings. 4. INSTALLATION 4.1 The: an aluminum flush glazedstorefront. system,. and -its- components shall be installed in strict compliance with the approved drawings.. 4.2. lie installation of this product will require a hurricane protection system 5.. LABELING 5.1 Each panel shall bear a permanent label with the manufacturer's name or logo; city, state and following statement: "Miami -Dade County Product Control Approved". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Duplicate copies of the approved drawings, as identified. in Section 2. of this Notice of Acceptance, clearly marked to show the components selected for the proposed installation. 6.1.3 Any other documents required by the Building Official or the South Florida Building. Code (SFBC) in order to properly evaluate the instal lion of this system. Manue Perez P.E., Product C o Examiner Produc ntrol Division " 2 of 3 Vistawall' Architectural Products ACCEPTANCE' No.: 00-0124.02' APPROVED; . MAY 2 g- 2000 EXPIRES : October 2.2003 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS Renewal of this Acceptance (approval) shall be considered after a- renewal application has been filed and the original submitted documents, including test -supporting data, engineering documents, are no older than eight (8) years. 2. Any and. all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approval". or as specifically stated in the specific conditions of this Acceptance. Renewals of Acceptance will not be considered if: a. There has been a- change in the South Florida Building Code affecting: the evaluation of this product and the produais not in compliance with the code changes. b. The product is no longer the sarne product (identical) as the one originally approved. C. If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of theproduct.. d. The engineer who originally prepared, . signedand sealed the required. documentation. initially submitted, is no longer practicing the, engineering- profession. 4. Any revision or change in the materials,. use, and/or manufacture -of the product. or process shall. automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) andgranted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a. Unsatisfactory performance of this product or process. b. Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6. The Notice of Acceptance- number preceded by the words Miami -Dade County, Florida,. and followed by the expiration. date may be displayed in advertising literature:. If any portion of the Notice of Acceptance is displayed, -then itshall be done,in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents,. where it applies, shall be provided to the user by the manufacturer or its distributors and- shall be available for inspection at the job site at all time. The engineer need not reseal the copies. 8. Failureto comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Notice of Acceptance consists of pages 1, 2 and this last page 3. END OF THIS ACCEPTANCE Manuel erez, P.E., Product C Examiner Product trol Division 3 of 3 1-3/411 1.1 10-1/411 ANCHOR LOCATIONS 1' 5-1/211 @ HEAD AND SILL I I ' 5- I / 2" A ANNLALLU uLnQv MHS HEAT-SGLASS ADDED NOTES & DWG No. 4./5/00 JG 11STAWALL ARCRITECTURAL PRODUCTS VPM=T I{p, REVISION DATE BY INFINITE LENGTH -310-I/ 10-I/4" I-3/4" 1 , 5 i' 5-1/211 'APPROV�O AS COMPLYING WITH THE . SOUTH FLORIDA BUILDING CODE DA E� P«OOL-.,T TROL DIVISION BUILDING CODE COMPLIANCE OFFICE icCEPTANCE NO. 6�2— 0124-02- DE SICsN ppESSURE RATING pCSTTIVE + 60psf GATIVE 60psf NOTE: "HURRICANE PROTECTIVE SHUTTERS REQUIRED. :DOLE FRAME ASSEMBLY -HSTS- STEEL 3 BOLTS ANCHORS PING SCHEDULE F 6 - I' 133 1 ENuM vJ Ant I ( I NT EXT ) 0 ATE 6-25-97 FG 200 �vm AWN BY PH I L CLARK FOR `DADE COUNTY, FLORIDA -.'O. FG-2000 F 3 0 M — BREAK SEALANT X 3/4" LG. FOR WEEPAGE. MULL 1 ADDED NOTES & DWG No. 4/ NO. REVISION D NOTE: "HURRICANE PROTECTIVE SHUTTERS REQUIRED." , ' FG-2164 ANCHOR --,- - I X 3 1 /2" LG. LOCATE AT 7" OFF CENTERLINE OF MULL -- & AT MIDLITE ��7'`� FG-2103 HEAD \,�:SEALANT TAPE . FG-1 133 GASKET SEAL -ALL CORNERS 1 /4" GLASS (TYP) ,,—SEAL' BETWEEN HORIZ & MULL Q FG-21 OS S ILL SEALANT TAPE FG-2-169 FLASH I NG , APPLY .062 ENDDAM AT JAMBS: BED I.N SEALANT ` / 16" O' ACCESS HOLES LOCATE AT t OF ANCHOR BOLTS Cz) Pi—R p4juA09, VISTAINALL - PRooucr Dv>3.oPM•xr OW fG-2163 ANCHOR X 3" LG. LOCATE AT 7" OFF CENTERLINE OF MULL & AT MI•DLITE. FG-2000 FOR DADE G,OUNTY, FLORIDA APPROVED AS COMPLYING WITH THE SOUTH FLORIDA BUILDING CODE DA E_. ALZ °C) H.? . _ PROD CT CQNTROL DIVISION ' BUILDS CODE COMPLIANCE OFFICE ACCEPTANCE NO. Q/Z4 •GZ. 4-1 /2" 2 HOR I ZON T ALS & MULLS AS SHowa ATE 6-25-97 RAWN BY PHIL CLARK WG . No. FG-2000 '- I'I 36 :TTING .00K -2104 1RIZONTAL Z F r i NOTE:-, "HURRICANE PROTECTIVE SHUTTERS REQLTIRED.W TOOL SEALANT INTO JOINT BETWEEN HORIZ.B MULL AT EXTERIOR ONLY!, TOOL. SEALANT INTO JOINT BETWEEN SILL & MULL AT EXTERIOR &.INTERIOR FG-2101 MULLION r---FG-2102 FILLER APPROVED AS COMPLYING WITH THE SOUTH FLORIDA BUILDING CODE x ti D pp FG - 2.16 4 ANCHOR - PHODUqj.PRTROL DIVISION BUILDING CODE COMPLIANCE OFFICE X 3 I / 2" LG. LOCATE AT ACCEPTANCE NO. C*l 02- 7" FROM -EACH END AND �� ;' �`►' 0 20 7 /8" O.C. -• ' r FG-Z169 FLASHING SEAL CONTINUOUS SEAL CONTINUOUS BETWEEN FILLER AND MULLION. EXTERIOR & INTERIOR. 8 1-3/4" RS-I II GA. (.III' THK.) STEEL REINFORCEMENT-. 1 ADDED NOTES & DWG No. . 4/5to0 JGI ISTAWALL ARCHITECTURAL PRODUCTS aA= 0 FG-2000 CnD N A n C rlZIiMTY GI nR I nit 1 —3/4•" I FRAME S BOLT • Cz� PC-R e��c� . /4" ATE 6-25-97 RAWN BY PHIL CLARK