Loading...
HomeMy WebLinkAboutProduct Control Notice of Acceptance; Series 375 Medium Stile Aluminium Storefront Door with Transomt ' M I AM I-DADE M NiIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 PRODUCT CONTROL NOTICE OF ACCEPTANCE (305) 375-2901 FAX (305) 375-2908 VistaWall Architectural Products CONTRACTOR LICENSING SECTION 803 Airport Road (305) 375-2527 FAX (305) 375-2558 Terrell TX 75160 CONTRACTOR ENFORCEMENT SECTION (305) 375-2966 FAX (305) 375-2908 PRODUCT CONTROL DIVISION Your application for Product Approval of (305) 375-2902 FAX (305) 372-6339 Series 375 Medium Stile Aluminum Stroefronr Door WITrnnsom under Chapter 8 of the Code of Miami -Dade County governing the use of Alternate Materials and Types of Construction, and completely described herein; has been recominerided for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This approval shall not be valid after the expiration date stated below. BCCO reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved mariner; BCCO may revoke, modify, or suspend the use of such product or material immediately. BCCO reserves the right to revoke this approval, if it is determined BCCO that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.:99-012104 Expires:10/03/2002 Raul Rodriguez Chief Pibdtiet Control Division THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE This application for Product Approval has been reviewed by the BCCO and approved by the Building Code aqi-ELQd_uct Review Committee to -be use. dan:pade County; Florida under the conditions set forth above. rancisco . Quintana, R.A. 2yector iami-Dade County Building Code Compliance Office Internet mail address: postmaster@ build ingcodeonline.com Ilomepuge: bttp://wi*w.buildingcodeonline.com Vistawall Architectural Products ACCEPTANCE No.: 99-0127:04 APPROVED : J U N 2 4 1999 „ EXPIRES October 03, 2002 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 1. SCOPE 1.1 This renews the Notice of Acceptance No: 954206.03, which was issued on October 03, 1996. This approves an aluminum storefront door system; as described in Section 2 of this Notice of Acceptance, designed to comply with the South Florida Building Code (SFBC), 1994 Edition for Miami -Dade County, for the locations wheel the pressure requirements; as determined by SFBC Chapter 23, do not exceed the Design Pressure Rating values indicated in the approved drawings. 2. PRODUCT DESCRIPTION 2.1 The Series 375 Medium Stile Alimiinuiri Otttswiiig Storefront Doors w%transom and its components shall be constructed in strict compliance with the following documents: Drawing No. CW-250-MSD titled "375 Aluminum Storefront Door (Mg). with Transom;" Sheets 1 through 7 of 7 dated 8-15-95 and revised on 5-20-99, bearing the MiamitYade County Product Control approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. These documents shall hereinafter be referred to as the approved drawings. 3. LIMITATIONS 3.1 This approval applies to single unit applications of pair of doors and single door with or without transom only, as shown in approved drawings. Single door units shall include all components described in active leaf of this approval. 3.2 Unit shall be installed only at locations protected by a canopy or overhang such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. Unless unit is installed in non -habitable areas where the unit and the area are designed to accept water infiltration.. 4. INSTALLATION 4.1 The aluminum storefront door system and its components shall be installed in strict compliance with the approved drawings. 4.2 Hurricane protection system (shutters): The installation of this product will require a hurricane protection system. 5. LABELING 5.1 Each unit shall bear a permanent label with the manufacturer's name or logo, city; state and following statement: "Miami -Dade County Product Control Approved". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance 6.1.2 The Notice of Acceptance of "Vistawall" Series CW-250-02 Window Wall system, as applicable. 6.1.3 Duplicate copies of the approved drawings, as identified in Section 2 of this Notice of Acceptance, clearly marked to show the components 'selected for the proposed installation. 6.1.4 Any other documents required by the Building Official or the South Florida Building Code (SFBC) in order to properly evaluate the installation of this system. lgl,a. 1. LtAltKei� lshaq I. Chanda, P.E. Product Control Examiner Product Control Division 2 of 3 Vistawall Architectural Products ACCEPTANCE No.i 99-0127.04 APPROVED JUN 2 4 1999 EXPIRES : October 03; 2002 NOTICE OF ACCEPTANCES STANDARD CONDITIONS Y 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation; including test supporting data; engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approved"; or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and 'sealed the required documentation initially submitted is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process. b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purpose. 6. The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The engineer need not reseal the copies. 9. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Notice of Acceptance consists of pages I; 2 and this last page 3. 1 Ska,q t • L. a d�. Ishaq 1. Chanda, P.E. Product Control Examiner Product Control Division END OF THIS ACCEPTANCE 3 of 3 MAX OC 5' STEEL REINFORCEMENT @ STD. MU�LION ONLY II ,. II 9 MAX 10 II MAX 7' D.O. It � II FB-1200 FLUSHBOLT BH-1 BUTT HINGE 10, MAX I - _1 1' MAX 7' D.O. 6'-4 1/2 MAX DC 5 MAX OC , ANCHORS LOCATED 3' FROM MEEACH END & 24' ❑C ,--I-- TYP @ HEAD FOR ALL DOOR CONFIGURATIONS. 6,-7' MAX 2 3 PB-11 T 10 3'-2 3/8' 7 INACTIVLI ACTIVE OP-11 INT. PIVOT ��FB-_ 1200 OP-9/OP-10 J FLUSHBOLT BOTTOM PIVOT OP--!6/OP-7 TOP PIVOT 6' —'—CL ❑F ANCHOR _ lw LCN 1054 SURFACE CLOSER /,,- 3 POINT LOCK OF ANCHOR --j % ,OC TYP 3 @ JAMBS 2'-6 7/16' 6• --1 CL OF ANCHOR I I 17 JACKSON MAX ❑VERHEAI 10, I II I I STEEL REINFORCEMENT @ STD. MULLION ONLY TYP @ JAMBS FOR ALL DOOR CONFIGURATIONS. ❑ MAX 4' FROM EACH END & 1' 4' O.C. TYP FOR ALL DOOR CONFIGURATIONS. WHERE WATER INFILTRATION REQUIREMENT IS NEEDED WHERE WATER INFILTRATION REQUIREMENT IS NOT NEEDED POSITIVE NOT APPROVED +70 PSF NEGATIVE NOT APPROVED -70 PSF NOTE= 1. DOOR SUBFRAME TO BE INSTALLED, EXCLUSIVELY IN A CW-250 ALUMINUM WINDOW WALL SYSTEM. 2. REFER TO SEPARATE VISTAWALL NOA SERIES CW-250_02 WINDOW WALL SYSTEM (SHOWN DOTTED). 3. DOOR EXTRUSIONS ARE 6063-T5 ALLOY, FRAME EXTRUSIONS ARE 6063-T6 ALLOY. 4. MIAMI-DADE COUNTY APPROVED SHUTTERS REQUIRED APPROVED AS COMPLYING WITII TIIC SOUTH FLORIDA BUILDING CODE DATE BY PRODUCT CONFROL OIV;S:ON BUII.D'•NG CODE COMPLIANCE OrFIc[ :CCEPTANCE NO.C��j__V_! ISTAWAL.L DATE: 8-15-95 SHEET 1 ARCHITECTURAL PRODUCTS 375 ALUMINUM STOREFRONT DRAWN BY: L.F.B. A PER DADE COUNTY 5/20/99 J.G. a7AIIIPMTMTMWUTX75160(M)MI.6100 DOOR (MS) WITH TRANSOM MM No. REVISION DATE BY ems" MACDWG. No.: CW250-MSD OF 7 MRMC WAN r 1 u� 1 1 1 1 1 tl 1' HAGER STEEL HINGE FINISH US26D SATIN CHROME FOR STANDARD FINISH. DURANODIC LACQUER PAINT FOR BRONZE OR BLACK FINISH. WEATHERSTRIPPING SCHEDULE DESCRIPTION PART NO. MATERIAL MANUFACTURER LOCATION GASKET 'CW-17 EPDM VISTAWALL EXTERIOR FRAME 5/16' X 5/16' DSA TAPE V-2110 THERMALB❑ND NORTON INTERIOR FRAME GLASS SETTING .BLOCK CW-51 EPDM VISTAWALL CW250 H❑RIZ DOOR STOP GASKET D-125 SANTOPRENE VISTAWALL FG-2120 DOORSTOP DOOR SWEEP D-120 SILICONE VISTAWALL D-118 DOOR STOP DOOR GASKET V-28 PVC VISTAWALL S-20 GLASS STOP MEETING STILE SWEEP WP-081 WOOLPILE VISTAWALL CW250 H❑RIZ -- DOOR SETTING BLOCK NSB-804 RIGID PVC VISTAWALL ICORNERS OF DOORS GLASS SCHEDULE DESCRIPTION 1/4' CLEAR TEMPERED GLASS �ISTAWALL ARCHITECTURAL PRODUCTS A PER DADE COUNTY 5/20/99 J.G. SMAMMIrr RD.rMU L-M7l160 (f ISI-61M MMVffrANo. REVISION DATE BY tMAKWA ,,u MCOa r amp ►.urrt,P�cnlan+o oo►.aAxv FASTENER SCHEDULE = DESCRIPTI❑N PART NO, MANUFACTURER LOCATION #12 X V PFH FS-323 VISTAWALL HORIZ & STEEL #12-14 X 7/8' HWH FS-327 VISTAWALL PRESSURE PLATES #8 X 1/2' PFH ' FS-2 VISTAWALL D-118 & S-20 1/4'-20 X 2 1/2' PRH FS-18 VISTAWALL GLASS JACK NYLONVISTAWALL GLASS JACK T TnOTH LOCKWSHR FS W-324 VISTAWALL SHEAR BLOCKS *10 X 3/4' PFH FS-7 VISTAWALL DOOR RAILS #12 X 1/2' PPH STS FS-27 VISTAWALL DOOR FRAME #14 X 1 1/2' PRH FA-229 VISTAWALL FRAME SILL 1/4-20 X V HEX HD FS-39 VISTAWALL FRAME RAILS 1/4' X 2' FH TAPCON THRESHOLD #10 X 3/8' PFH STS FS-119 VISTAWALL TOP DOOR STOP (EA. END) #10 X 2' PFH STS FS-201 VISTAWALL TOP DOOR STOP (CTR) 3/8-16 GARDE 5 BOLT VISTAWALL PERIMETER ANCHOR (HEAD) 3/8-16 SLEEVE ANCHOR WITH 2 PART EPDXY SET RED HEAD ITW PERIMETER ANCHOR (JAMBS) 3/8' FLAT WASHER FSW-80 VISTAWALL FRAME JAMBS #8-32 X 1/2' PFH MSIFS-50 I VISTAWALL IFLUSHBOLT BRACKETS ACCESSORY SCHEDULE DESCRIPTION - PART NO. PART NO. LOCATION MULL PLUG 457 -NIAGRA FRAME JAMBS SILL MULL ANCHOR CW250-FP-105 VISTAWALL SILL ANCHOR HEAD MULL ANCHOR CW250-FP-103 VISTAWALL HEAD ANCHOR SHEAR BLOCK CW250-FP-1 VISTAWALL TYP FRAME SHEAR BLOCK DOOR SHEAR BLOCK B10-D8 VISTAWALL TOP DOOR RAIL DOOR SHEAR BLOCK B10-D71 VISTAWALL BOTTOM DOOR RAIL DOOR SHEAR BLOCK B10-DII VISTAWALL MUNTIN 375 ALUMINUM STOREFRONT DOOR (MS) WITH TRANSOM DATE: 8-15-95 DRAWN BY: L.F.B. DWG. No.: CW250-MSD MROVED AS COMPLYING WITII Till ;OUTH FLORIDA BUILDING CODE q TY PRODUCT CONTROI DIM ON BUILDING CODE COMPUANCF Ofi ICl 4CUPTANCE NO. =d1-Z�-�— SHEET 2 OF 7 w 21 1+1 O 6' SEE NOTES A K B 0 6 1/2' 5' CW250-FP-103 CUT LENGTH = 4 11/16' I I FSW-80 WASHER ' A PER DADE COUNTY 5/20/99 J.G. No. REVISI❑N DATE BY a 0 FS-27 SCREW FSW-324 WASHER CW250-FP-1 MULL PLUG P/N 457 V ISTAWALL ARCHITECTURAL PRODUCTS IMMMRS RD.nWM ='rX7516D C"351.61W M VMAP/A1L OROU! aunt MAMurAcnran+0 pp1 MANY NOTE, C 3/8'-16 HEX HD BOLT GRADE 5 DRILLED & TAPPED INT❑ STRUCTURAL STEEL. FS-229 (1/4' MIN THICKNESS) r @ OF LITE ❑PN'G 1 \ CW-187 7/32' X 1/2' PRE -PUNCHED SLOTS FOR SCREWS TYP I F'S-327 12' OC TYP 2 1/2' CW-17 J 1/4' TEMPERED GLASS —/ O NOTE: A RED HEAD ITW 3/8'-16 SLEEVE ANCHORS WITH 2 PART EPDXY SET INTO 4000 psi PRECAST CONCRETE 1 1/2' EMBEDMENT. NOTE: B RED HEAD ITW 3/8'-16 SLEEVE ANCHORS WITH 2 PART EPDXY SET INTO 1500 psi PRECAST CONCRETE 1 1/2' EMBEDMENT. 375 ALUMINUM STOREFRONT DOOR (MS) WITH TRANSOM FSW-80 WASHER la FS-323 TYP I 2 REQUIRED ACCESS HOLE CW250-FP-1 V2110 6 7/16' DETAIL 1 IS FOR ILLUSTRATION PURPOSES ONLY. NOT PART OF THIS APPROVAL. SEE WINDOW WALL SYS FOR REFERENCE DETAILS. DATE: 8-15-95 DRAWN BY: L.F.B. DWG. No.: CW250-MSD CW-658 PPROVED AS COMPLYING WITH TIIE OUTIFLORIDA BUILDING CODE hTE+LbA) P 2 LA--- __ RODUCT CONTROL DIV!S UN UILDING CODE COMPLIANCE OFFICE CCEPTANCE NO. ��.- �5 --()—Li SHEET SHEET 3 OF 7 At" lt-' 2 1/2' 2 FS-27, #12 X 1/.2' PPH STS REQ'D. 4' FROM EACH SIDE OF HEADER � II W 6 7/16' V-2110 �— FS-323 CLOSURE WITH CW-17 CW-51 7/32' x 1/2' PRE PUNCHED SLOTS FOR SCREWS FS-327 12' OC TYP CW-157 —� CW-49 FS-27 --A-- 412 X 1/2' PPH 24' OC DS-104 USE FS-119, #10 X 1 3/8' PFI-4 STS 13/16' FRE❑M EACH END AT CORNER PLATES. USE FS-201 410 X 2' PFH STS AT � AND 19' IN EACH DIRECTION. 5/8' X 3/4'-4, FAB FROM AN-1. SECURE TO F-1 HEADER W/ 4 FS-27, #12 X 1/2' PPH STS 1' FROM EACH END &. 2 EQUALLY SPACED. 1/4' TEMPERED GLASS FS-27 SCREW — FSW-324 WASHER .. { ♦ .. ♦ . . .. . . . . .. . 'd'� 11111ililii �01 D-125 FG-2120 CW-656 CW250-FP-1 CW-689 APPROVED AS COMPLYINC WITII TIIF. SOUTH I' ORIDA DIIILDINC CODE DATlaj%_ y Q _ I l._ NOTE: _ l 1 'F' CLIP MUST BE INSTALLED IN F-1 HEADER AND THEN SECURED TO SUB FRAME JAMBS. PRODUCT CONTROL DIV;S-ON 2. CLDSER PLATE IS SEALED TO HEADER. UUILMNU CODE COMPLIANCE OFFICE 4CCEPiAi\CE NO.�ll -Q"l •• r? 1 ITAWALL T DATE: 8-15-95 SHEET 4 ARCHITECTURAL PRODUCTS 375 ALUMINUM STOREFRONT ❑NT DRAWN BY: L.F.B. A PER DADE COUNTY 5/20/99 J.G. em0lrr Ra7ZRV l:7%731d0 (9ts)Sl1a100 � MM�a� DOOR (MS) WITH TRANSOM No. REVISION DATE BY W-rn= �1J COWAW DWG. No.: CW250-MSD OF 7 ®1 V- S-20 D-71 EXTERIOR , FS-39 1/4-20 X V FS-323 012 X 1V ' ""' TEMPERED GLASS SEALANT TYP. Ir►Q�i3' icy S-2 08 X 1/2' PFH TOP & BOTTOM AILS, .2 SCRS. 5' FROM EA. END VERT. TILES, 4 SCRS. 5' FROM EA. END AND VERT. SPACED. D-118 BED IN SEALANT FS-2 0 8 X 1/2' DI120 PFH 12 ❑� I 1/4' X 2' FLAT HEAD % TAPC❑N 1 1/2' MIN EMBEDMENT. BED PERIMETER OF -A THRESHOLD IN SEALANT o�6 1/2' I TH-49 TRIM SEALS TO BUTT EACH OTHER ON PAIRS OF DOORS. PERIMETER SEAL ALL THRESHOLD HLS. PROVIDED FOR FLUSH -BOLTS, DOOR LOCKS, AND CONCEALED ROD PANIC DEVICES. 4' NOTE: D-120 WEATHER SEAL - MATERIAL. 50 DUROMETER SILICONE. BY EPG.. NOTE: SEAL FRONT (SEE NOTE) AND 1/4' BACK TOP AND BOTTOM ❑E MIN FG-2120, 3 SIDES. t 1 1/2' FG-2120 SEAL GLZ. PKT. BEFORE INST. FG-2120 17/32' AB CW-689 SEALANT NOTE: 1. ANCHOR THRESHOLD TO SLAB ONLY. 2. STD PREP FOR O.P. a,_RED HEAD ITW 3/8'-16 SLEEVE ANCHORS WITH 2 PART EPDXY SET INTO 4000 psi PRECAST T EMBEDMENT 4 PERIMETER SEAL UNDER SIDE OF MULL ANCHOR, ONCE SECURED SEAL OUTSIDE OF MULL TO SLAB AND ANCHOR PERIMETER. SEAL SUBFRAME, CW-689, TO MULL, CW-686, ANCHOR AT SLAB. O — 6 1/2' CW-656 SEE NOTE DETAIL 7 IS FOR ILLUSTRATION PURPOSES ONLY. NOT PART OF THIS APPROVAL. SEE WINDOW- WALL SYS FOR REFERENCE DETAILS. 'ROVED AS COMPLYING V11TH THE 1TH FLORIDA BUILDING CODE )DUCT CONIROL DIVIS ON ILDING CODE COMPLIANCE Orr10E )EPTANCE wISTAWALL DATE, 8-15-95 SHEET 5 ARCHITECTURAL PRODUCTS 375 ALUMINUM STOREFRONT A PER DADE COUNTY 5/20/99 J.G. 90AMFOU=TMUtE.lX731l0VM351-4100 DOOR (MS) WITH TRANSOMMMVMADRAWN BY: L.F.B No. REVISION DATE BY BMENNAMMALWIlAMOD ANY DWG. No.: CW250-MSD OF 7 1/4' MAX SEE NOTES A & B MOTE: A RED HEAD ITW 3/8'-16 SLEEVE ANCHORS WITH 2 PART EPDXY SET INTO 4000 psi PRECAST CONCRETE- 1 1/2' .EMBEDMENT. NOTE: B RED -HEAD ITW 3/8'-16 SLEEVE ANCHORS WITH 2 PART EPDXY SET INTO 1500 psi PRECAST CONCRETE 1 1/2' EMBEDMENT. CW-1 NOTE• X 04 2 1/2' STL CHANNEL FAB FROM GALVANIZED SHEET STOCK W/ EXPOSED ENDS ETC. GALV. COATS CW-6 CW-689 FG-2120 >KET FS-27 TYP.--­�t #12 X 1/2' IM PPH 24' DC ---i BA-26 FS-22 FS-22 CW-685 V I I CW-157 7/32' X 1/2' PRE -PUNCHED SLOTS FOR SCREWS (TYP) 2 1/2' 72' 8 A PER DADE COUNTY 5/20/99 J.G. No. REVISION DATE BY I S TAWALL. ARCHITECTURAL PRODUCTS IM AMMRT RD. 78RAKI TX 77160 (9 3514100 THE VMUWAIL GROUP BUTLER MANUPAC URM COMPANY ffN=Ea tEim-lm IBH-1_// CW-17 375 ALUMINUM STOREFRONT DOOR .(MS) WITH TRANSOM CW250-PP-16 1-1/2' X 4-1/4' 10go STEEL CHANNEL 6 7/16' N❑M FS-323 24' ❑C PLUS 3' & 12' FROM EACH END �,- V2110 1/4' TEMPERED GLASS J �'I-- CW-49 FS-327 12' OC TYP 9 CW-157 DATE: 8-15-95 DRAWN BY: L.F.B DWG. No.: CW250-MSD PROVED AS COMPLYING WITII TIIE UTH FLORIDA BUILDING CODE i ODUCT CONTROL DIV!S•ON ILDiNG CODE COMPLIANCE OFFICF CEPTA?ICE NO, �t�1�-oy SHEET 6 of 7 S-20 1/4' TEMPERED GLASS 1 V -28 SEALANT FS-2 08 X 1/2' PFH TOP & BOTTOM RAILS, 2 SCRS. 5' FROM EA. END VERT. STILES, 4 SCRS. 5' FROM EA. END AND VERT, SPACED. — 4 1/4' D-24 L , - No 1 3/16' X 1 7/16' CHANNEL ATTACHED W/ FS-39 1/4-20 X 1' BOLT THRU CORNER BLOCKS. NOTE: 1. STL CHANNEL COATED W/ ZINC CHROMATE PRIMER. 2. PERIMETER SEAL GLASS TO DOOR PERIMETER IMMEDIATELY INSTALL DOOR AND ADJUST IN NORMAL MANNER. 3 APPLY THIN BEAD OF SEALANT AT INTERIOR OF ADJUSTABLE ASTRAGAL AFTER ADJUSTMENT FOR FIT AND CLOSING SPEED ARE MADE. SO-UTl ED As COMPLYING WITH TIIF OUiI�IORIDA BUILDING CODE Y --A5�, ROOUCi CONiNOI DIV;S.ON r UIlOiICG CODE COMPLIANCE OFFICE CEPFANCE N0. q9�p ISTAWALL, DATE: 8-15-95 SHEET 7 ARCHITECTURAL PRODUCTS 375 ALUMINUM ST❑REFR❑NT A PER DADE COUNTY 5/20/99 J.G. °m"DoarPD. MIRML-MIB °M551.61W DOOR (MS) WITH TRANSOMnm DRAWN BY: L.F.B No. REVISION DATE BY "6T"w"uoxOo DWG. No.: CW250-MSD OF 7 eurs�e auxuPncnrxa+a oo►vj►xr