Loading...
HomeMy WebLinkAboutRevision; Interior Changes on EquipmentSep 04 011.0:.39a Building Zoning SLC OFFICE USE ONLY: DATE FILED: 9117161 REVISION FEE: ST. LUCIE COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDNG & ZZONNG 2100 VIRGNIA AVENUE FORT PIERCE, FL 34982S652 56I-462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFOR-NIATION 1. LOCATION/SITE: ADDRESS: 8490 Commerce Center Drive 2. DETAILED DESCRIPTIONS OF PROJECT REVIS10\S: Interior changes on equipment 3. CONTRACTOR INFORSI.�TION: S1'. OF F'L REG:/CERT# CB-0058887ST. LUCIE COU.NTY CERT.s BUSI\ESS\A3I$: Great Dane Petroleum Contractors, Inc. Qualitiers-.Name: F. Marrell Jerkins ADDRESS: 14274- CITY:. Wallingi-nn� SPATE: FL ZIP:33414 PHONE (DAYTI>IE): a 725-5529__ _ FAX # 954954-725_55-3 4. AWOMVENGINEER D.F. Consultants, Inc./William Duffey, P.E. ADDRESS; �b� SheriStreet, #136 CITY: Pemhrnkp � STATE: FL ZIP: 33024 PHONE (DAYTI.NIE): 95a-a�_aRaF . e _ FAxa 954-431-8332 561 462 1735 p+2. PERMIT NUMBER: Al 0'-?-0b RECEIPTNO,: 41/ REVISIONS BY 4A WOOD COLUMNM.S.C. 09/17/01 DRAWN R.BROWN CHECKED DATE 01-05-01 SCALE AS NOTED JOB NO. 01-2524 SHEET A01 OF SHEETS ■ ■ SECTION "A -A" SHT A08 I i z Co o" I- a s vmi a6'-8" 6 3' 4" ,-0" COOLER COOLER FREEZER:2aa CE OPEN AIR �- 2 ffi ND COND M KER DELI COND C ND. COND. 22'-0' CONDM CT 01MI p C7 C7 C7 OC7 C7 O C7 C7 C7 C7 G A OX ICE MAKER �LOOOOIW / REMOTE WORK O N ELECTRICN Cb D. UNIT ® COUNTER \ / — R N SHAND INK / x I CONVEY WALK-IN WALK—IN w OVEN FREEZER COOLER 0 F_ _1F 71— 7F F 77F_ —IF_ —I F —17 7F —1 — this shlbe 'o I II II II o ( I II II II I I II II I unit to SODA Q- REFRIG. or shorter for N FOUNTAIN N PREP. TABLE COUNTER OI WALK—IN door clearance GpJ 00 a COOLER ®°® =EM_ _ _ _ _I BEVERtj AGE C LINTER 4NEEZE GUARD i GRIDDLE Xi 0 S w � 12 I I. I _ STORAGE � I FRYER M N ❑° \ / I w I � I m � w I OVEN 42" HIGH SNEEZE GUARD) 0 v P WORK I b I o pp�Op pp��0 OOP. I TABLE L e 6'-2„ 0 I a'-o„ G2� I xx o CCL °\ EXIT \ D4 SIGN D5 .. 3'-4" Z(B HAND SINK n \ O /S UTILITY �\\ o ROOM I \� I 4,-10 36 HIGH,LOCKABLE \ \ - MEN S SWING GATE FURNISHED - / \` 0 WITH COUNTER PACKAGE \ 6 5 g F/DI \\ LAV 03 CHECKOUT COUNTERS Q \�\\ M D3 I _ TRANSACTION �O \\�\. d W/C AREA OMEN'S I ° OFFICE OFFICE �I EMERGENCY SHUT OFF ICE � <0� ATM n n I. n ka„' m _ kk' m w m. w.mn n D2 CREA l i CASE EXIT MACH. SIGN TS4X4 TS 4 TS4X4)(I\ 1 23'-4" 5'-6" 5'-8" 5-6" 6,_8„ FLOOR PLAN v mo z 00 SCALE: 1 /4„ _ V-O" oma WOMEN'S HANDICAPPED TOILET ELEVATIONS: Et J NOTES: DRAFTSTOPPING CORNICES SBC 2305.2:4 PROVIDE DRAFTSTOP AT 20'-0- O/C W/ 5/8" TYPE "X" GYP.BD. AT CORNICE (IF REQUIRED) NOTES: FIRE EXTINGUISHERS PROVIDE -5LB. 3A40BC TYPE, FIRE EXT. (TOP OF EXTINGUISHER SHALL NOT EXCEED 5 FL ABOVE FINISH FLOOR). PARTITION NOTES:i FINISH SCHEDULE WOOD STUD PARTITl01NS (NON BEARING) 3 1/2" 0 24" O.C., 1/2" GIP. BOARD ATTACHED WITH ROOM FLOOR BA$ a WALLS SALES AREA CERAMIC TILE STR B IGHT SE PAINT (P-1) 1 3/8" DRYWALL NAILS ®8 O.C, STAGGER BD JOINTS 24". METAL STUD PARTITIONIS (NON BEARING)' 3 1/2", 20 GA 0 24" O.C., 1/2" GYP BOARD ATTACHED TO STUDS AND (RUNNER TRACK WITH 1" TYPE S-12 DRYWALL SCREWS TOP & BOTTOM' TRACK W/i/2STUDS H TYPEED TO SACH SIDE OF12 PAN HEAD SCREWS.' -. CASHIER AREA CERAMIC TILE STRAIGHT BASE PAINT (P-1) HALL CERAMIC TILE STRAIGHT BASE PAINT (P-1) - RESTROOMS CERAMIC TILL MATCH WALL TILE NOTES: CABINETRY. OFFICE CERAMIC TILE STRAIGHT B SE PAINT'(P-1) /� LEGEND 36" HIGH x 36 " WIDE x 36" DEEP H/C SERVICE COUNTER W// PLASTIC LAl,�. COUNTERTOP (NEVAMAR UBERTY BLACK SLATE) TYR 42 HIGH SERVICE COUNTER W/ STORAGE BELOW PROVIDE PLASTIC LAM. COUNTERTOPS §VAMAR LIBERTY BLACK SLATE) PLASTIC LAM. CABINET FROM5.(NEVAMAR BLACK SLATE) PLAST. LAM. COUNTER EDGE (CHERRY RED) : FIELD CHECK ALL DIMENSIONS W/ EXISTING CONDITIONS and 'CONDITIONS AS THEY PROGRESS THROUGH THE JOB. AFTER FIELD CONFIRMATION OF REQUIRED DIMENSIONS, PROVIDE CONTRACTOR W/ SKETCH LAYOUT S40WING CONTROL DIMENSIONS NECESSARY TO BE MAINTAINED FOR PROPER CABINET INSTALLATION.. (SEE SHOP DRAWINGS PROVIDED BY CABINET MANUF. AND APPROVED BY OWNER) PROVIDE ALL BLOCKING REQUIRED TO SUPPORT ANY WALL MOUNTED EQUIPMENT 8" CONIC BLOCK`: EXTERIOR WALL STORAGE UTILITY VINYL TILL STRAIGHT BASE PAINT(P-1) Partition W01 - 2 x 4 wood or 3 1/2 " metal Studs W/ 1/2 " drywall both sides - WALK-IN 'COOLER CONCRETE Walk-in Cooler wall (4") PIZZA/ DELI AREA CERAMIC TILE TILE Walk-in Freezer well (6") —�--I I I o o IIIIIIIIIL71111�IIIIIIIIIIIL7111111111111111111110111111111111111 TS4X4 TS4X4 TS4X4 TS4X4 ',.3'-2„ ,_10'' 6, 0,... 8„ NOTE: 15'-4 :OWNER TO SELECT- ALL FINISH COLORS PRIOR TO STARTOF CONSTRUCTION mmo 0 amo 00 a¢ � I )OA9 /9/01 MEN'S — HANDICAPPED TOILET ELEVATIONS:ELII % 5 A4' A5 A2 I Al P2 B1 - , i SEC ION 11 A A" SHT A08 NOTE: L. ALL ROUGH OPENINGS. SHALL BE CONFIRMED WITH OWNER'S SELECTED DOOR OR WINDOW MANUFACTURER'S RECOMMENDATIONS. 2 ALL DOOR HARDWARE SHALL BE AS SELECTED BY OWNER (WITHIN BUILDER'S CONTRACTED ALLOWANCE) 3 ALL EXTERIOR DOORS WITH GLASS SHALL BE TEMPERED (INCLUDING SIDE LIGHTS AND TRANSOMS. 4 ALL EXTERIOR DOORS SHALL HAVE CONTRACTOR SUPPLIED PRODUCT APPROVAL 5. ALL WINDOWS SHALL. HAVE CONTRACTOR SUPPLIED PRODUCT APPROVAL AREA: FLOOR AREA 3413.33 SQ. FT GREATER THAN 2,250 SO, FT. - 2 EXITS GENERAL ARCHITECTURAL NOTES: 1. GENERAL A. ALL WORK SHALL BE IN ACCORDANCE WITH MANUF. RECOMMENDATIONS AND INSTRUCTIONS, AND/OR WITH INDUSTRY STANDARDS. 2. STOREFRONT A STOREFRONT TO BE KAWNEER FA -SET 400, UNITED STATES ALUMINUM CORPORATION SERIES OS-451 S, OR APPROVED 4 1/2" EQUAL ALUMINUM SYSTEM. B. GLASS TO BE 1" TEMPERED INSULATED CLEAR, C, INSTALLATION TO BE IN ACCORDANCE WITH MANUF. RECOMMENDATIONS AND SPECIFICATIONS D. ENTRANCE DOORS: --NARROW STILE DESIGN IS 1 3/4" THICKNESS. - FINISH TO MATCH STOREFRONT. 3.INTERIOR WALL FINISHES 1. TYPICAL INTERIOR PARTITION WALLS TO CONSIST OF 2x4 WOOD OR 20 GAUGE 3 1/2" METAL STUDS 16" ON -CENTER; WITH 1/2- GYPSUM WALLBOARD EACH SIDE 2. TYPICAL EXTERIOR WALLS TO CONSIST OF 1/2" GYPSUM WALLBOARD OVER P.T: ix4 FURRING STRIPS ® 24" O.C. ON 8" CMU.,(TYPICAL). 3.` ALL GYPSUM WALLBOARD TO BE TAPED, SPACKLED & PAINTED 4. ALL WORK SHALL BE IN ACCORDANCE WITH MANUF RECOMMENDATIONS AND SPECIFICATIONS 1` CEILING CEILING REMARKS_ HEIGHT (ALL FINISH MATERIALS TO HAVE CLASS-"C" FLAME SPREAD RATING) SEE FLOOR: PLAN AND REFLECTED CEILING: PLAN. OPEN TO ROOF OPEN. TO ROOF VINYL OR CERAMIC TILE WILL BE A FIELD. OPEN TO ROOF OPEN TO ROOF BUSINESS DECISION, PAINT ON .GYP. BD. 8'-0. SEE FLOOR PLAN AND REFLECTED CEILING PLAN PAINT ON SEE FLOOR PLAN AND REFLECTED CEILING PLAN GYP. BD. 8'-0" SEE TOILET ELEVATIONS FOR TYPICAL TILE PATTERN. PAINT ON GYP . BD." 10'-0" SEE FLOOR PLAN AND REFLECTED CEILING PLAN PAINT ON GYP, BD. 10'-0" SEE FLOOR PLAN AND REFLECTED CEILING. PLAN SEAL FLOOR WITH MASTUREKURE 20OW OR APPROVED EQUAL PAINT ON GYP . BD. 10'-0" SEE FLOOR PLAN AND REFLECTED CEILING PLAN FINISH SCHEDULE -ELEVATIONS MAF_K DESCRIPTION FT.' 1$" (DAL F69 IMPERVO or opp. equal) CERAMIC TILE W/ (L&M ACID RESISTANT) GREY GROUT FT2 8"x 8' (DAL F69 IMPERVO or opp equal) CERAMIC TILE W/ (L&M ACID RESISTANT) GREY GROUT FT3 1/8" x 12" x 12" ARMSTRONG 'STEP MASTER -50702 SUP RETARDANT VINYL TILE FLOORING (COLOR: SLATE) B1 4"'COVE CERAMIC BASE WPt WALL PAINT: SHERWIN WILLIAMS No 1039 (ZURICH WHITff EGG -SHELL LATEX ENAMEL. (2) COATS'PROMAR 400' OVER i(1) COAT PROMAR 400 LA __X WALLL PRIMER WP2 DOOR AND TRIM PAINT: SHERWIN WILLIAMS No. 1039 ZURICH WHITE) SEMI GLOSS ALKYD ENAMEL. (2) COATS "PROMAR400 OVER (1) COAT 'PROMAR 400' ALKYD ENAMEL PRIMER Li PLASTIC LAMINATE COUNTER AND CABINET FINISH FORMICA (COLOR: COASTAL RED) WITH SPARKLE FINISH. :, L3 4"X4° CERAMIC WALL TILE. .CEILING PAINT: SHERWIN WILLIAMS No. 1039 (ZURICH WHITE) EGG -SHELL 'PROMAR.400' C2 LATEX ENAMEL- (2) COATS `PROMAR 400'. OVER (1) COAT -LATEX PRIMER DOOR SCHEDULE MARK AMT. MATERIAL ROOM III SIZE FINISH THRESHOLD REMARKS Di 1 PAIR ALUMINUM SALESROOM 3' 0' X 71-0" X 1 3/4"- SILVER GRAY ALUMINUM ADAMS RITE DEAD BOLT LOCK W/THUMB TURN ELECTRIC RELEASE LATCH STRIKE CONTINUOUS DUTY -FAIL SECURE. D2 2 HIM (STL) RESTROQM X 1 3/4" PAINTED NONE HM W/DOOR CLOSER, "D" RATED HINGES & LOCKSET, LEVER TYPE HANDLES D3 2 HIM (STL) OFFICE . I 3' O" X 6'-8" X 1 3/4" PAINTED NONE '. HM.W/DOOR CLOSER, "0" RATED HINGES & LOCKSET, LEVER TYPE HANDLES 04 2 HIM (STL) EXTERIOR 3'-0" X 6'-8" ,X i " X 6' 8 - PAINTED NONE HM W/DOOR CLOSER "D" RATED HINGES " & LOCKSET, LEVER 1`YRE HANDLES DOOR TO BE TURN W1 PANIC HARDWARE D5 2 HM (STL) DELI/UTILITY AREA 3' O" X 6'-8" X 1 3/4" PAINTED NONE 'Hal W/DOOR CLOSER, "D" RATED HINGES & LOCKSET, LEVER TYPE HANDLES NOTE: FIXED GLASS AND FRAMES M MATCH ENTRY DOORS. (TEMP. GL.) (PROVIDE ARCHITECT APPROWD SHOP DRAWINGS) ri COPY THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES, O D.F. CONSULTANTS, INC. CIVIL ENGINEER: WILLIAM DUFFEY, P.E. 9000 SHERIDAN STREET SUITE 136 PEMBROKE PINES, FLORIDA 33024 (s.. TELEPHONE: (954) 431-4846 P.E.# 0024433 - E.B.# 0007007 U m COOLER COOLER FREEZER 7.5 TON 3.5 TON 7.5 TON COND COND COND ACCU ACCU ACCU 1 2 3 M CT DISC p O C7 C7 C7 C7 C] C7 O C7 O C7 C7 � C7 O � � II II II I I II II II I I II II IF o \ OVEN HOOD MAKER ICE OPEN AIR DELI COND COND. 2 WALL TREATMENT (SEE NOTES) -8„ Fly I � � 7�5H DO CUO 1X 2 4A C—�"T�CC7T� o MS M4S BC - 1 - / ® 00 tj "'�V NJ 1�nv UPPER FACADE SYSTEM(S) NEEDS A,110V HARD WIRE SERVICE EACH LOCATED ON BACK SIDE OF SOFFIT AND ABOVE DROP CEILING INTO JUNCTION BOx FR WALL SWITCH TO TURN ON/OFF IS ALSO REQUIRED ALL OUTLETS ON THE BACK WALL SHOULD START 1 2 0 OFF THE FINISHED FLOOR FRONT COUNTER ELECTRICAL CONDUIT NEEDS TO BE RUN UNDER ,I PT I OV. CABINET AND STUBBED UP THROUGH BOTTOM OF COUNTER 4A I SA ALL POS SYSTEMS IN FOOD SERVICE - NEED T0. BE ON A SEPERATE DEDICATED LINE I - I SK A °— SK �I I 2A O IIZI 1111111 � I XLL� I AT IC M 0 00 0o O O FOOD SERVICE AREA EQUIPMENT PLAN 1 SCALE: 1/4"=1'—O" MANUFACTURER REF MODEL TYPE VOLTS AMPS P HEIGTH/WIDTH/DEPTH DESCRIPTION 1313-1 -- BAG -IN -BOX -- -- 1 89 40:5 37 BAG -IN -BOX ON ISHELF OR UNDER COUNTER SK-1A 414-16-3-18 SINK _- -- - 37 90 25.5 STAINLESS STEELITHREE COMPARTMENT SINK W 2 SETS OF HOLES FOR 1 2" HOT & COLD LINES. SK-2A -- HAND SINK -- -- - 14.25 19 14.75 STAINLESS STEEL HAND SINK W 4" GOOSENECK FAUCET. IC-M -- UPRIGHT ICE MACHINE 208 15 1 -- BC-1 BC-100 BEVERAGE CENTER 115 2 1 34 22 30 COUNTER TOP DISPENSER 125 lips OF ICE STORAGE CAPACITY . CD-6 -- DELI CASE 120- 23.3 'rt1 6' -- T-1A T2430EB TABLE -- -- ° 34.5 30 24 STAINLESS STEELIWORK TABLE. PT-4A 8262 5' PREP. TABLE < 120 6 1 51 62.33 STAINLESS STEEL FRONT & SIDES REFRIGERATED PREP TABLE W 4 SHELVES. OV-5A -- CONVECTION OVEN -- 27 1 18 55 31.5 STAINLESS STEEL FREE STANDING GAS OVEN. 34,000 BTU GR-1 -- GRIDDLE - 12.5 1 33 48 30 STAINLESS STEEL FREE STANDING GAS GRIDDLE. 100,000 BTU OV-4A -- CONVEYOR OVEN 208 27 l 1 -- FREE STANDING CAS OVEN. 80,000 BTU H-1 OVEN HOOD -- -- - 24 120 48 3150 CFM EXHAUST HOOD H-2 -- OVEN HOOD -= -- - 24 48 48. 1400 CFM EXHAUST HOOD EX-F2 - EXHAUST FAN -- - 34"' DIA 1 HP EXHAUST FAN' EX-F1 - EXHAUST FAN -- - 23' DIA 1 4 HP EXHAUST FAN SU-F1 - SUPPLY FAN -- -- - 16 7 8" DIA 1 1 2 HE FRESH' AIR SUPPLY FAN T-1 IOT3036 OVEN TABLE -- -- - 30 24 36 STAINLESS STEEL OVEN TABLE W-/CASTERS & UNDERCOUNTER 'DRAW. FR-1 - FRYER - - - - GAS FRYER 45,0 O, BTU) M-1 ID SIGN 120 6.5 1 - SOFFIT SIGN MS-4 -- 4-PANEL MENU 120 4 1 22 88 5 ANGLED 4 PANELI MENU SUSPENDED FROM DROP CEILING TW-1 -- TABLE W SINK -- - 34,5 48 30 STAINLESS STEEL WORK TABLE W SINK, CO-2 -- CO2 TANK - - - -- FL-T1 FA-2VP TRIPLE -CS WATER FILTER -- - - AMERI-PURE IC -CI LBN- 4 ICE CREAM CASE 120 15 - -- HUSSMAN AT-M INCR 5670 ATM 1120 1 20 -: -- NCR ARCHITECTURAL SYMBOLS =INDIRECT DRAIN Q =FLOOR DRAIN 11 -COLD & HOT I WATER LINE =COLD WATER LINE Q =GAS LINE q� =110/120V SERVICE EX 208/240 SERVICE F, � 0'-0" A.F.F. IIIIIII ELEVATION HEIGHT x DRAWING TITLE XX X EX SCALE: 1 /4° 1'-0" F2 ELECTRICAL PANELS ALL FOOD SERVICE < EQUIPMENT SHOWN AND SCHEDULED SHALL BE FURNISHED BY ORION UNLESS OTHERWISE SPECIFIED A. Contractor shall unload, store, move equipment into building and safe guard (including insurance coverage) all equipment. (Note! Most equipment will be staged and delivered at one time. B. Owner will install all food service equipment. C. Contractor shall mechanically and electrically hook—up all equipment. D. (contractor shall install the hoods and fire suppression systems. E. Contract shall install other equipment as needed during construction "as listed on the drawings, including (but not limited ,to) the following: 1. Hoods. 2. Walk —In` freezer/coolers. 3. Roof top curbs. 4. All Drive thru monitors and detection loop. (pulling wires and installing computer p.o.s. system) 10'-0" A.F.F. .di" ELEVATION HEIGHT 70 1 1 0' 0" A.F.F. UU 5'-6" ELEVATION HEIGHT Py 1 SEAIING'SECIIONAL ELEVATION ell A02.1 SCALE. 1/;4'=1'-0" crib VL: THESE PLANS AND ALL RN/ OPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. 10,-0„ I. 10. 0" g__�SC­ALE RIMARY &SECONDARY SOFFIT SECTIONAL ELEVATION: 1/4"=1'-0„ ® D.F. CONSULTANTS. INC. CIVIL ENGINEER: WILLIAM DUFFEY, P.E. 9000 SHERIDAN STREET SUITE 136 PEMBROKE PINES, FLORIDA 33024 tnw C. TELEPHONE.(954) 431-4846 P.E.# 0024433 E.B.# 0007007 CRAVOM R. RB OWN CHECKED DATE 01-05-01 AS NOTED JOB NO. 01-2524 SHEET A02.1 OF SHEETS —PREFINISHED STANDING PREFINISHED STANDING SEAM ROOFING SEAM ROOFING _12 6� 'PREFINISHED STANDING SEAM ROOFING 0 PREFINISHED STANDING I. SEAM ROOFING STANDING SEAM -- 3' DIAMETER INTERNALLY ILLUMINATED 16" C/C PEGASUS DISC (TYPICAL) STANDING SEAM 16" C/C 3' DIAMETER. INTERNALLY ILLUM PEGASUS DISC (TYPICAL) NATED `n r PREFINISHED STANDING °' PREFINISHED STANDING {F4l� RflOFINf. CFm Pnr)riNG � , ,. ' VV111Lb1: 111111 /1vb Arl'LfVAYYb YV MYV� l U z IN ®®0 DRAWN R.BROWN CHECKED DATE 01-05-01 SCALE JOB NO. 01-2524 SHEET A05 OF SHEETS vw� vroo.erv. an. azumnr-ennrmm , eousa u. t k f r L O I N M I I I I I I O O cD N I I o I 0 I 0 N I — COOLER COOLER EZER I. COND COND OND 7 B TON 3.5 0 7.5 TON ICE OPEN AIR A U ACC ACCU MAKER DELI _ 2 3 COND. COND. M I I I 1 I I m w m. m m m II � II 1 II I 1I I LAM ISX12 STRINGER T p„ II III I i II II II II II III I wl �I I l Iw wl Imo, I FI I Iw I� I I 'I I I I BELE DERE STRUCTU E, SEE DETAIL I -- ---- --- I I 1 wl I �I I I w_ III I �I �I B I� 118 I __ I- II \ / III \\ I �I B 8 �I ICII %I y �I Ix xl I`v.. I I �I Ix IN ¢I �/ 1I QI Iq LI to I I. \\// I I of I� xl to NI Ix xl IN NI Ix xl INI NI of 11 NI �. itI IN I — — — I I — — --1 I I 5 8" ALL THREAD (TP. 5) I BELEVEDERE. STRUCTURE I ) SEE SOFFIT DETAL B � I I LAM 5x12 STRINGER II II �� II I II II II I III III \\I I I i, III I III III I I' I ( I II II l II \ II II III I \ SEE SOFFIT DETAIL A \� I \ I I ¢,:� \ m 2"x 6" 16 GA. m SEE SOFFIT DETAIL B m m I m m r METAL JOIST n n n n \ Q 8'-:3" `— p Z XZ X Z X� x jCZ Xg 0 O (n0 N O NO U_--. U Z z X� x:t 2" 6' 2' ,_2" 6 2„ o I 5, .: 6' 8„ 12'-0" -._ 12'-0" , 86'-8" 0 m ROOF FRAMING PLAN N m a m c i 3 LL N POTLATCH "LOCK -DECK" WITH SMOOTH SURFACE FINISH (EXPOSED TO INSIDE OF SALES BUILDING) 3"X6" X 12''MIN. LENGTH. FASTEN AS FOLLOWS. 1. TOE NAILED AT 30" O/C ALONG EACH COURSE WITH 8d NAILS, OFFSET NALES 15".IN ADJOINING COURSES. 2. FASTEN TO 5 X 15 GLUE LAM BEAM SUPPORTS "W/ (2) 8d. NAILS 3. END JOINT NAILS AT 12 O/C MAX. EACH SIDE. CD J m y w y N m N m m N I LL w m LL TIE BEAM REINFORCING NOTES TIE COLUMN REINFORCING BAR SPLICES' SHALL BE LAPPED 30" MIN. VERTICAL REINFORCING BARS SHALL BE PLACED IN CONCRETE FILLED CELLS AND SHALL EXTEND INTO THE FOOTING AND TIE BEAMS, ALL SUCH BARS SHALL BE CONTINUOUS AND SHALL TERMINATE AT EACH END WITH A STANDARD "A.C.I." HOOK. SPLICES IN TIE BEAMREINFORCING STEEL ON STRAIGHT RUNS SHALL BE PROVIDED BY LAPPING A MIN. 30". SPLICES IN THE BEAM REINFORCING STEEL AROUND CORNERS SHALL BE PROVIDED BY BENDING TOW BARS, ONE OUTSIDE TOP AND ONE OUTSIDE BOTTOM AROUND THE CORNER A MIN. 30", OR BY ADDING TWO #5— REBARS. ONE OUTSIDE TOP AND ONE OUTSIDE BOTTOM WHICH EXTENDS EACH WAY 30" FROM THE CORNER SCALE: 1 /4" 1'-0" --I O O U U O � I Im 2 -0" IEl I I I I _ I I I I� 0 BEAM SCHEDULE NOTES 1. SCHEDULED HOOPS OR STIRRUPS SHALL BE PLACED AT EACH END OF BEAM UNLESS NOTED OTHERWISE STIRRUPS SHALL BE. TYPES-6 & HOOPS SHALL BE TYPE T-2 TYPICAL CRSI BAR BENDS UNLESS NOTED OTHERWISE. 2. BUNDLE ALL STRUCTURAL BEAM TOP BARS IN PAIRS OVER SUPPORTS WITH TOP BARS FROM ADJACENT BEAMS. 3, ALL CONCRETE BEAMS OTHER THAN THOSE WITH THE PREFIX TB SHALL BE POURED PRIOR TO. PLACING OF BLOCK BELOW 4. ALL TIE BEAM REINFORCING SHALL BE 'CONTINUOUS THRU TIE BEAMS ONLY. ALL SPLICES TO :BE A MINIMUM OF THIRTY SIX (36) BAR DIAMETERS. 5. ALL TIE BEAM TOP REINFORCING SHALL EXTEND INTO SPAN OF ANY ADJACENT STRUCTURAL BEAM AS PER BENDING DIAGRAM. 6. DROP BOTTOM. OF TIE BEAMS AS REQUIRED AT WINDOW AND DOOR HEAD (28" MAXIMUM) TO FIT BLOCK WORK. ADD #5- REBAR FOR EACH 8" DROP AND BRING UP TO TIE BEAM WITH: A MINIMUM 6" OVERLAP (FOR BEARING), 7. TIE BEAM SCHEDULED DEPTHS ARE MINIMUM AND MAY BE INCREASED (8") MAXIMUM) TO FIT BLOCK WORK. (OR SEE NOTE #6) 8. ALL ADDED LONGITUDINAL BEAM REINFORCING. SHALL EXTEND 6" :MINIMUM INTO SUPPORT UNLESS NOTED OTHERWISE. 9. MARK "C" IN REINFORCING COLUMN BETWEEN TWO BEAMS INDICATES THATREINFORCING SHALL BE CONTINUOUS TiRU THESE TWO. BEAMS S 1 S-2 S-3 BAR (EN ) qATO 'EreATOP BA P BA BAR FHOOPS TOM. BAR BOTTOM BAR }4' BOTTOM BAR o= STRRU 3" MIN. LOPS or STIRRUPS D FROM SPACED FROMRT FACE A I SUPPORT FACE AS \-3/8" STEEL U-BRACKET` 4" 16 GA. TRACK 12'-0" I. 12 0" 12' 0;: 2,_0„ 4"SOFFIT WALL FILEo I 2" x 6" 16 GA METAL TRACK N SIMPSON U210 FASTENING 5/8" ALL. THREAD 2" x 6" 16 GA METAL JOIST HEADER 10-3/16" x 1 1/2" TAPCONS - JOIST /C 6 10d x 1.1/2" 4" 16GA.TRACK ALLOWABLE LOAD 825# 2%6" 16 GA METAL JOIST 2%6" 16 GA METAL JOIST HEX HEAD SELF DRILLING #10 0.183") SHEAR - 363# PULLOUT - 132# 4'-0" HEX HEAD SELF -DRILLING #10 0.183") SHEAR 363# PULLOUT 132# SOFFIT DETAIL A SOFFIT DETAIL B SCALE: 3" - V-O" SCALE: 1 1/2" = V-O" THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY f"V CORRECT 0 NS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. p D.F. CONSULTANTS. INC. CIVIL ENGINEER: WILLIAM DUFFEY, P.E 9000 SHERIDAN STREET SUITE 136 PEMBROKE PINES, FLORIDA 33024 tfim C:. TELEPHONE: (954) 431-4846 P.E.# 0024433 - E.B.# 0007007 Q O LL z O U w J V DRAWN R.BROWN CHECKED DATE 01-05-01 SCALE AS NOTED JOB NO. 01-2524 SHEET A07 OF SHEETS U z RNI _ ... I'..'�1.. HVAC SPECIFICATIONS SECTION 15A PART 1: GENERAL 1. In general, the work consists of the Intent of these drawings and specifications, furnishing all materials and equipment and in performing of all labor and services necessary to complete the Installation of operating HVAC system(s) and associated work ns shown, specified and requested. 2. Comply with the 94 edition of the Standard Mechanical COOLER C OLER FREEZER 7.5 TON 3.5 TON 7.5 TON ICE OPEN AIR Code, local statutes and ordinances, obtaining required permits, COND CND COND .ACCU ACCU ACCU MAKER DELI :and coordinatingthe work. g Q 1 2 3 COND- COND. 3 Ductwork :shall follow SMACNA recommended procedures for 7/8" DIA 3/8 DIA 16"x25" fiberglass duct. M CT DISC 4. Furnish a 5.-year Warranty on all compressors .and a 1-year ❑ O C7 C7 0 o C7 ❑ O O E 1 C] C7 O C] O El OO O O service and guarantee on all controls and equipment. F/A INTAKE T 10' GI. /- T • PART 2: PRODUCTS 22 \AN #1� 22" (� FAN #2 1. Condensate lines shall be 3/4".schedule 40 PVC 1/2" DIA 3/8" DIA AT t0' Q `� I I terminating Into French drain as shown T _ II , 2. Temperature control with wall mounted thermostat and n� \ x \\ ;; �-1/2" DIA remote sensor shall automatically cause a sequenced heat or 3.5 TUN \ 1s.f., k ,.:. L" \ \,. \1Q© , , \ \ \ \ x \ \ \ ., \ cool " cycle to ',maintain space temperature. Wire auto position to 1 3/8, DIA DUCT SMOKE DETECTOR \14 \ ka y A.H.U. `> \ \ l \, : \,\ 1 k \ \ "\ :ti `;\ .' ;\ k;T \ `'\ ,,\\ .\:^ , \\ P P k. \\ ..\ S D. 1.;\\\ \ \ \\: k-^-;5- ,.,L a� . \\, ti.:; :-''\{-+S \` \;§^1,;3` lk \\,.,� b e on .... W R MOTE STATU.\a <.. 2 \ \ \ \\�, ' .\,,,. \. , „ k Y \.\Yc -.,\ \\, \ . \\ `~,. ,;.,\ : �, - CATOR (AU IB E - 800 900 \> 3 Manual dampers shall have quadrant Indicating handle with ZONE #1 7I �� 7 F s \." \ CFM position locking set screw. VISIBLE �'\ \ \,�\\;,''. ! V CFM 20' FAN #3 P 9 ... \` I 4. Grills, registers, and diffusers are shown with pattern, ",• k,\ 1000 \\, � and arrangement. Fixtures equal in appearance and performance \ ,\ CFM t` 0 will be acceptable. \Y ` \Y �� 5 Flexible duct connector shall be hung above the ceiling insulation. Connector shall have. minimum F-Factor of .45 @ 1000 \ \- kT J FPM, UL 18T listed and complywith NFPA 90 A. Installation :e�4 /A INTAKE •` \ ti .S, . �. '•\ \ `..-_ \. ZONE 3.. ; \-\ E shall .comply withFloridaEnergy Code. 280 280 280 280 280 # \`\ 7I 6. Rectangular fiberglass duct shall be manufactured from ` CFM .OEM lCFM lCFM. :1CFM ,\ TI6"'. 0 strong resin bonded fiberglass formed into rigid boards faced on 1 000 \ ` one side with fire resistant foil-SRIM KRAFT vapor barrier, L24"X24"RETURN AIR CFMstandard duty type EI-800, 1 1/2". thick. Closure shall be made GRILLE IN WALL ABOVE COOLER .with staples, glass mat, and mastic equal' to Foster. 7. Smoke detectors in=the 1 \,,.: su 50 I .and return ducts shall be CENT\ , h wired to shut down a/c system. Install per,NFPA-72E. 8. Cooler and Freezer Refrigeration lines shall be copper with 3 4 closed cell insulation all per mf recommendations. \:..,' 24"X24 RETURN AIR \\', .. \ \ x \k ;, \ i, ,:\,Equal fans by Dayton, Breezemaker, Penn, Gook, Acme, or Broan k vv v •,.. y/v T ''Ak GRILLE IN WALL ABOVE r �6 s k, - - are acceptable. .COOLER P. ' 1000 , 10. Metal spiral duct with 1" insulation "spiraaoustic" 6y mansville 7.5 TON CFM \ o I A.H.U. I L w \'>` 0 PART 3: EXECUTION 3000 ZONE #2 \\ ,\ w 1 For air regulation and at branch take offs, Set air CFM o \\ �; flows shown for fixtures with manual dampers. 0 2 Fiber glass duct shall be carefully crafted with ship lap k " DUCT SMOKE DETECTOR AC UNIT 3 12.5 joints and seams into the %I2es shown for inside dimensions. \ T I TON I 3. Contractor shall log his own test and balance of the HVAC system ti W/ REMOTE STATUS LOCATE HVAC THERMOSTATS AT CASHIER. AREA A.H.U. Per Florida Energy Code 41 Q,1.ABC. Air flows .shall be adjusted as INDICATOR (AUDIBLE EACH THERMOSTAT TO HAVE A REMOTE SENSOR.. W/ R SMOKE DETECTOR � 9Y J ti\ \ VISIBLE FOR AREA OF CONTROL W/ REMOTE STATUS #3 required to obtain indicated flows. -Equipment shalt operate y\ I quietly ,and be installed such that its operation shall cause no \\ INDICATOR (AUDIBLE vibration in the adjacent structure and shall result 4\d X i VISIBLE D perceptive Y in no objectionable noise. k CEILING \\\ I',, 4 Control wlrlrig. shalFberouted in the interior building AT 10'-0" \\\- . \\+ wall and above ceiling. \\\ ,f CEILIN k . ' 0 AC uNIT 1 \ AT 8' ~ 00 5 Acceptance of work shall be after approvals by building officials \titti h !CFM AC UNIT`2 \ \ : \\E have been signed and debris, excess material, equipment, scra , \� \ OT \ \ \\\ ,\P \`\ k t , ; \\ a a etc. have been removed \ \ 6. Cooler and ice machine refrigeration lines shall be routed overhead \.. %N" F/A to exterior building wall and down inside and then through to AA ,.::\ INTAKE con e sors: \. ,,... ti V... , , \ . `T3tA\... \ H•-5c'EL ._.�\ ;,., -,.,.....\ .,< \ > Y I\ .*'-:'h`` \ . - \\ Soo I soo Soo 1, 500 100 " GENERAL NOTES CFM CFM { CFM + CFM .CFM N\\ 1CFM ` ' 1 INTERIOR DUCT WORK. SHALL BE PRE -FABRICATED FROM 1 1/2` { O\ ZONE #1 \ THICK S.D. FIBERGLASS DUCT BOARD, VAPOR SEALED WITH R-6 VALUE. l.. ". 24 X24 RETURN AIR\\ a \\ \ \\- \ \, 2. RETURN AIR GRILLE SHALL BE PERFORATED TYPE TO MATCH -SUPPLY, \. \ GRILLE IN WALL AB \ , \. \\ \ \. o - - _� '-: \\ RESTROOM ENTRY \\' \\` k\\ 4 ��M FILTERS SHALL BE LOCATED JN GRILLE + 3 ALL GRILLES SHALL BE ALUMINUM. PERFORATED SUPPLY GRILLES w CEILING CEILING ' . CEILING CEILING SHALL HAVE ADJ, O.B. DAMPERS WHERE FLEX CONNECTOR JOINS DUCTS AT 10'-0" AT 10'-0" ,, „- _. .. AT 8° 0" AT 8'-0" t0O - 100 ,= IIII 4 FLEXIBLE DUCT SHALL BE UL`APPROVED AND LABELED CLASS 1 AIR DUCT, 14 FEET IN LENGTH MAXIMUM CFM 1CFM ,< III 5 ALL SQUARE ELBOWS SHALL HAVE TURNING VANES. ALL TEES SHALL HAVE TURNING VANES AND SPUTTER DAMPER. PROVIDE BALANCINC III DAMPERS AT ALL BRANCH DUCT TAKEOFFS ill 6. ALL WORK TO BE PERFORMED IN ACCORDANCE WITH APPLICABLE ' - = OO C7 EDO O BUILDING CODES ORDINANCES AND FLORIDA ENERGY CODE. �T 7. AIR CONDITIONING SYSTEMS SHALL BE EQUIPPED WITH A SMOKE DETECTOR CONTROLLED SHUTDOWN SYSTEM. SMOKE DETECTORS SHALL BE INSTALLED IN BOTH SUPPLY AND RETURN DUCTS. 8. GENERAL CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY ROOF PENETRATIONS A PROVIDE 4" THICK CONCRETE 9. GENERAL CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY N VIEW FOR HVAC PLAN EQUIPMENT FOR THE COMPLETE INSTALLATION, START-UP AND BALANCE (SEE PLAN VIEW FOR LOCATION) - OF HVAC SYSTEM IN ACCORDANCE WITH PLANS AND MANUFACTURER'S NEC CLASS 1 WRING SCALE: 1/4"=1'-O" NOTE: INSTRUCTIONS. TO BLOWER MOTOR RELAY TO POWER WEATHERPROOF SUPPLY DISCONNECT SWITCH COOLER/FREEZER COND. UNIT FURN. AND INSTALLED BY EQUIPMENT VENDOR REFRIGERATION PIPING, CHARGING, START-UP, AND LOW VOLTAGE ELECTRIC WORK BY VENDOR STUCCO 48" OVERHEAD CLEARANCE INSTALLATION OF COOLER DOORS AND HIGH NEC CLASS 2 WIRING -�� FINISH' - VOLTAGE ELECTRICAL WORK BY CONTRACTOR. 12" REAR AND SIDES UNIY SIZE : 39" X.34" X 41" : O TYP. AC-1, AC-2 & AC-3 O TO COIL... O O O ANCHOR TO SLAB W/ (4) 3/8"x 2 1/2" CONC: EVAPORATOR UNIT O � � REDHEAD ANCHORS EXISTING 6" INSULATED PREFABRICATED STEEL m m n n �NEW 4" REINFORCED CONC SLAB .WALL PANEL SYSTEM 4" "'CE ACCESS' ST UNIT ON RUBBER TRUSS ENGINEER To REVIEW & APPROVE ALL STEEL To BE A36 TO- OUTSIDE AIR INTAKE SHALL BE A MINIMUM 10 FT. FROM EXHAUST MOUNTING DETAIL OF AIR HANDLER ALL BOLTS TO BE. A307 AND SANITARY r VENTS. 11. OPERATION /MAINTENANCE'MANUAL SHALL BE PROVIDED TO THE HEAT EXCHANGER O DERATURE O O.- TROL SEAL OPENING(S) WITH CLEARANCE ELEVATOR GROMMETS PERMAGUM OR EQUIVALENT TO REDUCE NOISE AND ALLOW FOR PROPER DRAINAGE PITCH SLAB REFRIGERATION PIPING TO COMPLY WITH ANSI/ ASME B31 5 OWNER. 12. REFRIGERANT SHALL BE NON-CFC SUCH AS R-22 OR H134A (GROUP AT) CFC'S SUCH AS R-12 ARE NOT ACCEPTABLE 13. HVAC CONTRACTOR SHALL FURNISH AND INSTALLUNITSCOMPLETE INCLUDING, BUT NOT LIMITED TO, UNITS, DUCTWORK, REGISTERS AND THERMOSTATS. 14.HVAC CONTRACTOR SHALL PROVIDE SEQUENCING CONTROLS TO. BRING THE HVAC UNIT ON LINE P Y BASED. UPON THE LOAD. EQUIPMENT SCHEDULE (ALL EQUIPMENT TO BE PHASE 3) NEW HVAC UNITS AH-1 HP-1 AH-2 HP-2 AH-3, HP-3 NOMINAL TONS: 7.5 TON 3.5 TON 12.5 TON TRANE AIR HANDLER#: TWE090A300 TWE042P13O TWE180B300 TRANE HEAT CONDENSOR# : TTA A 090300C TTP04 C300A 2 TTA150B300C TOTAL CAPACITY (BTUH) 75,570 41,316 149,000 HEATER KW 7.5 KW 7.5 KW 7.5 KW SUPPLY AIR: 3000 CFM 1400 CFM 5000 CFM OUTSIDE AIR: 205 CFM 205 CFM 205 CFM SEER 8.90 12.05 10.30 MCA: rAIR HANDLER/HEAT: PROVIDE UNITS WITH THE FOLLOWING' 1 REMOTE RA SENSOR IN RA DUCT ell r! POWER SUPPL FOR NOTE : ALL OUTDOOR WIRING MUST BE WEATHEIRPROOF. AWAY FROM BUILDING REFRIGERATION S STEM SUPPLY &RETURN PIPING TO BE FULLY INSULATED. 2. SMOKE DETECTOR SHUTDOWN SYSTEM SLEEVE AND SEAL THRU WALLS AS REQUIRED. CSSOR WSTALLATION (TYP) TYPICAL COOLER FREEZER COND. WSTALLATION SCHEMATIC _� EXISTING 6 INSULATED PREFAB NOT TO SCALE NOT TO SCALE STEEL WALL PANEL SYSTEM NEW NON FUSED DISCONNECT 3 2 POLE RELAY AT BOTH EF-1'S FOR NT WITH AH-2 & AH-3. ` .3 13/4 ":. CONDENSATE LINE FROM 1-1/2" x 24 GA DEEP .DRIP PAN SHALL TERMINATE TO EXTERIOR OF BUILDING INTO A 100 x 24" LONG. PIPE WITHOUT COVER, FILLED WITH '3/47 CRUSHED ROCK IN THE NOTE: SUPPORT PVC CONDENSATE 9 HUSSMAN PERVIOUS AREA NEXT TO HEAT PUMP PER SPEC 4606.7 .SCROLL TYPE. STEEL HOUSING WITH WHITE BAKED ENAMEL FINISH PIPE PER MANUFAOTURER'$', REQUIREMENTS ELECTRICAL JUNCTION BOX o. o PERFORATED CAP 4" OUTLET W/ VINYL - DRAIN LINE REQUIREMENTS SHALL BE BACKDRAFT DAMPER (MANIFOLD EXHAUST ! - IN ACCORDANCED WITH TABLE 46-C ANCHOR TO SLAB. W/ FAN OUTLETS AND "' OF THE ST.B.C. 4 3 8"x 2 1 2" CONC. O' / / DUCT THRU ROOF W/ 000000 6" 0 - TERMINATE MIN. o �0000 o 000 8" ABOVE ROOF oo�o oo 000000000000� MIN: EQUIPMENT REDHEAD ANCHORS - N � 8" 0 9 BLADED PROPELLER FAN \ DRAIN PAN SLOPE 1/8" PER 1' 0", J. RP T Y MOUNTED TO 1100 M MOTOR DIRECTLY MOU TE Y-POLYSTYRENE GRILLE WHITE COLOR RUN TO DRYWELL (SEE PLAN) 3/4" CONDENSATE DRAT I BROAN #626 - 110 CFM EXHAUST FAN I:.. TYPICAL CEILNG EXHAUST FAN DETAL CONDENSATE DRAW NOT TO SCALE NOT TO SCALE • 2. INSTALL WATER LEVEL FLOAT SWITCH IN DRIP PAN WITH SHUT OFF 4" PVC CAP SWITCH FOR OVERFLOW CONTROL. 3. MOUNT AH-UNIT & DRIP PAN ON RUBBER: VIBRATION. ISOLATORS BETWEEN NEW 4" 0 STL. BUMPE ,,tA y DRIP PAN & PLATFORM FRAMING. SEAL MOUNTING SCREWS To PAN TO POST FlLLED W/C'�j PLANS AND ALL PROPOSED WORK PREVENT LEAKAGE. (FRAMING SHALL BE UNISTRUT 1-5/8" CHANNEL BRIDGING. N 2 REOD PER UNI1) p p� Airy �y pry^ OPTIONAL - SEE SITAWSUBJECT TV CCRI'IECIIONS 4. LIQUID & INSULATED SUCTION LINES FROM AIR HANDLER UNIT SHALL BE ROUTED ABOVE CEILING & DOWN IN EXTERIOR WALL. TO HEAT PUMP ' M F11\I NEW 4" THICK SLAB W/t�llIRED BY FIELD INSPE ORS THAT ,,,,IT (REIN. X 10/10 W W.M. AY NECESSARY IN 0 _ -EXISTING ASPHALT OR C�CRET - N DER T4 .� ` i �i�i�°✓✓°�°J✓°i°i�i I SUB -GRADE NOT COOLER COMPFESSO R SLAB DEETAL 174 lo I SCALE P'\\\'\1%Q\ww ® DHP.WN R.BROWN CHECKED DATE 01 05 01 SCALE AS NOTED JOB NO. 01-2524 SHEET M1 OF SHEETS FAN #1: DAYTON 3C757 11 7/16" IN —LINE FRESH AIR FA 3905 CFM 1 1/2 HP, 1522 RPM 115/230 VOLT 3 1/2" METAL FRAMING W/ 5/8" TYPE "X GYPSUM BOARD ON BOTH SIDES ILL DESIGN #U425 IN —LINE SUPPLY N 2034 CFM CONSTRUCTIONI NOTF-S EXHAUST FAN #3 1. SUPPLY & EXHAUST FANS ARE INTERLOCKED WITH A PILOT LIGHT IN KITCHEN AREA FIRE MODE REQUIRES THE EXHAUST FAN TO CONTINUE TO OPERATE, SUPPLY FAN STOPS AND! ACTIVATES BUILDING ALARM SYSTEM. 3. HOOD EXHAUST FAN SHALL OPERATE WHENEVER THE EXTINGUISHING SYSTEM IN ACTIVATED 4. FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE HAZARD AREA SHALL BE ARRANGED FOR SIMULTANEOUS AUTOMATIC OPERATION UPON ACTIVATION OF ANY OF THE SYSTEMS - COMMON EXHAUST DUCT FOR MORE THAN ONE HOOD WOULD DEFINE A SINGLE HAZARD AREA. EXCEPTION WOULD BE A SECONDARY FIRE SUPPRESSION SYSTEM CONTAINED IN THE COMMON EXHAUST DUCT. EXHAUST FAN #2 HEAT EXTRACTION NO FIRE SYSTEM 1S REQUIRED' NO DOUBLE WALL DUCTS ARE REO'D d 1" MIN. AIR SPACE N 22—GAUGE SHEET METAL DOUBLE WALL WELDED VENT PIPE W/ 1" MINERAL WOOL f 6„ z MIN. No MAXIMUM HEIGHT wxf my% ,,ems AFF GREASE CUP— FIRE SUPPRESSION 3" AIR SPACE NOZZLE MIN. 1 PER APPL 18 GA STAINLESS STEEL OR 16 GA GALVANIZEDSHEET METAL --- — OR TILE WALL COVERING ELECTRIC FRYER r y 24" HIGH STAINLESS STEEL TABLE'ni w „r. 1 10' 0" HOOD 3 1/2" METAL FRAMING T-0' W/ 5/8" TYPE "X" GYPSUM BOARD ON BOTH SIDES /so' ILL DESIGN #U425 2'-2" o 0 61 � 8 N 8" CBS WALL 10' GREASE HOOD GREENHECK CUBE 180-10 OR EQUAL' 18" EXHAUST FAN 3380 CFM 1 HP, 1180 RPM 115/230 VOLT" EXHAUST HOOD PLAN VIEW J SHOP DRAWING SHALL BE SUBMITTED TO ENGINEER!! AND BUILDING DEPT. FOR APPROVAL PRIOR TO HOOD/FAN INSTALLATION 1L ' 4'-0" 10' 0" I 6„ MIN MIN. EXHAUST HOOD DETAIL/WALL SECTION SCALE: 3/4"=1'-0 LECTRIC STOVE ELECTRIC GRIDDLE w 24" HIGH STAINLESS STEEL TABLE EXHAUST HOOD E RejviSion Sloe 9114101 n III HEAVY DUTY / ELECTRIC FRYER ATION/WALL SECTION SCALE: 3/4"-1'-0' THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. ® D.F. CONSULTANTS, INC. CIVIL` ENGINEER: WILLIAM DUFFEY, P.E. 9000 SHERIDAN STREET SUITE 136 PEMBROKE PINES,' FLORIDA 33024 C. TELEPHONE. (954)431-4846 tINn 6 P.E.# 0024433 - E.B,# 0007007 U z DRAWN C.D.L.S. CHECKED DATE 09/13/01 SCALE 3/4' =1'-0" JOB NO. 01-2524 SHEET M-1.1 OF SHEETS REVISIONS BY ADD T.P. NOTE 04.30.01 J.G.R. COOLER COOLER FREEZER _ 30"x3O" . TO POST -MIX 75 TON 3.5 TON 7.5 TON- ICE OPEN AIR DISPENSER COND COND COND ACCU ACCU ACCU MAKER DELI CAN 1 2 3 COND. COND. CHECK LPA 20" x g•' VALVE. PRESSURE. WATER FILTRATION SYSTEM (ABOVE) - GAUGE � WALL PLATE WATER MANIFOLD (BELOW) 1/2"COLD M CT DISC WATER SUPPLY O ❑IIIIIII loll❑ C7 ❑ O C7 O ❑ ❑ O ❑ C7 ❑ O O O ElEl0 0 - - _ �.. ___ 12 1/2CW TUDOR " 0 N ., 1 2 HW 1/2„ CW �, ll. )�IVEN ,.. 1/2„ HW J. SHUT-OFF \ L. _ _ J'a, TO COFFEE I� - - VALVE (TYP.). cv MAKER,Ul' j- ' ICE MAKER � f.. " 2.SAFE WASTE Y\ C� � 2" � C � COARSE FILTER iMF _ _�j "•0 3" FD I (TYP. 3) MC MC MC TYP. -I'i.F 7I I' 71--7 iF_. „EVERPURE" #9330-43SYSTEM CSR WATERFILTRATION SYSTEM, WT. 40 LBS. � --- FIN. FLR. WATER FILTRATION SYSTEM. � 1 -1Q SCALE: NONE ..,EVERPURE 'MODEL #9330-43 SYSTEM CSR /. /'SYSTEM CSR MODEL 4 F OC71-MC TRIPLE WATER FILTERS, ONE COARSE FILTER, ONE IMF PHOSPHATE FEEDER, EVERGUARD-II LOW PRESSURE -\ E 115/60/1-.2i A. ALARM, MOUNTING PLATE, I-i'', ACTIVATION INCOMING WATER GALVE FOR M GAUGE AND AN INSTALLATION KIT. II INSTALL: (6) 3/8" DtA ( ....._ Fl - I E E E PLUMBING MATERIAL EQUIPMENT SCHEDULE FURNISHED & INSTALLED BY GC MARK TYPE NOTES H.W. C.W. WASTE VENT DESCRIPTION WATER 1 /2" 3" 2 AMERICAN STANDARD 2168..128 ELONGATED SIPHON WC CLOSET A,B,D ACTION. W/OLSONITE #95 SEAT -OPEN FRONT. WHITE LAV LAVATORY A,C,D 1/2" 1/2" 1 1./2" 1 1/2" AMERICUCETAMOD# STANDARDMOD# 0321.075 19"W X 17"D FD FLOOR DIE 3" P AVC ODDITIES PGA 720 DRAIN OSD OPEN SITE DIE 3" 2" JOSAM 30000-E3 DRAIN CO. CLEANOUT D SEE PLANS PLASTIC ODDITIES PCO 700 3-COMPT D 1/2 1/2 2 "DUKE" THREE COMPARTMENTS, 3CS SINK 2 W/.TWO DRAINBOARDS W27" OPTION:CPR 3EF. SPLASH MOUNT OVERHEAD SPRAY W 12" FAUCET MS MOP D E 1/2" 1/2" 3" 1 1/2" FIAT. MODEL #TSB 3010 24"X24"X12" :SINK .PROVIDE CHICAGO MODEL: #835 SINK FAUCET WATER "RUUDGLAS" MODEL RP 401.. 40gal. WH HEATER 3/4"...3/4" DEL ELEMENT OR EQUAL HB HOSE _ 3/4„ FURNISHED & INSTALLED BY GC _ _ BIB APPROVED BY. FIELD ENGINEER (PARKER) HAND A,C,D 1/2" 1/2" 3" 2„ '"REGAUNE" MODEL 7 G-601, 12-1/2"X18-1/2" CUT OUT HIS SINK 1OX14X5 BOWL, GOOSE NECK FAUCET, HUDEE RING W/ CLIPS, FAUCET, AND DRAIN, OR EQUAL. FIXTURE NOTES. ' A. PROVIDE CHROME PLATED ANGLE STOP W/.WHEEL HANDLE & ESCUTCHEON AND TUBING RISER ON EACH SUPPLY B. PROVIDE BOLT CAPS W/ RETAINER CLIPS - C. PROVIDE CHROME PLATED TAILPIECE, P-TRAP & TUBINGEXTENSIONTO WALL D. APPROVAL REQUIRED FOR SUBSTITUTION £.,.PROVIDE TRAP BELOW FLOOR E Y\✓ —1/2"HW: 1/2" CW Lt AIV lllll CLEAN 1/2" CW OUT _1/2" HW u., 1 1. Z:, — 1/2" CW • -.1/2" CW 2" REVFNT 750 GALLON GREASE TWO WAY -INTERCEPTOR CLEAN' OUT HW � FILE COPS PLUMBING PLAN PLAN SCALE: 1/4"=1'-0" ti S o WATER HEATER tilj �R� V v' V iOn O MOP BY 40 GAL OWNER 20-1/4"X59-1/4° 1 /2" POP -OFF ` ,���THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS y REQUIRED BY FIELD INSPECTORS THAT ARRANGEMENT MAY BE NECESSARY IN ORDER TO To sU I T �'�� e �G CAN wnsH COMPLY WITH ALL APPLICABLE CODES. CONDITIONS CD M S P1 ti 3„ V.T.R. 2' STUDOR 3" V.T.R. 1 VENT � 3 HOSE BBB HAND '\ 00 H BI 2" REVENT � ( / 0 24 ELEVATION MOP SINK NO SCALE PLUMBING NOTES and SPECIFICATIONS 1. PROVIDE WRAP TYPE INSULATION FOR ALL WATER LINES ELEVATION WATER HEATER NO SCALE / SINK ,G J�6 3., \ 3-COMP, ✓ 3„ SINK / MOP 2 SINK 3" � � 2" -- 3 2' � C 0. 750 .GAL. 2" SAFEWASTE L_ HAND I C.O. 3 4" C.O. GREASE TRAP 3„ 3.: 2" STUDOR SINK 3" F.®. GO 3" F.D. VENT C O 3" O.. HAND p SINK C 0: 3" 3" y 2" STUDOR tpE PA VENT TO SEWER RR FOUR FEET OR LESS FROM OUTSIDE OF BUILDING WALL. O 3" L 2" SAFEWASTE 2. PROVIDE NECESSARY UNIONS TO FACILITATE REPAIR GS�SQ�P OF EQUIPMENT AND FITTINGS. OVERFLOW TO go J k �GREF 3. SUPPLY AND WASTE LINES UNDER HANDICAP LAVATORIES MOP SINK BELOW S�o� SHALLBEINSULATED. NO SHARP OR ABRASIVE SURFACES SOOP 3" F.D. ALLOWED. 1/2" COLD WTR. SUPPLY / HOT WATER HEATER ohs 4. ALL PLUMBING TO CONFORM TO ALL APPLICABLE CODES. MTD: ABOVE MOP SINK 5. ALL VTR TO BE 10 MIN. FROM HVAC' INTAKE. � EE REFER' TO DETAIL ON 55 S6R� y P 6. ALL DRAINAGE, WASTE, STORM, VENT AND PIPING WITHIN AND UNDER HOT WTR. LINE THIS SHEET 5����� • THE BUILDING SHALL BE P.V.C. SCH 40. ALL FITTINGS S SHALL BE BY SAME MANUFACTURER, NO MIXTURE OF FITTINGS WILL BE ALLOWED. hw2 1" SANITARY LINE ISOMETRIC 7. ALL COLD AND HOT WATER PIPING SHALL BE TYPE "L" SEAMLESS COPPER TUBING: ASTM B88-839 WITH CAST COPPER FITTINGS; �ET/11 NO SCALE ANSI B16.18-1984. AI GREASE LINE ISOMETRIC NO SCALE ® D.F. CONSULTANTS. INC. CIVIL ENGINEER: NLLIAM DUFFEY, P.E. 9000 SHERIDAN STREET SUITE 136 PEMBROKE PINES, FLORIDA 33024 INC. TELEPHONE: (954) 431-4846 P.E.# 0024433 - E.B.# 0007007 W _J LLI F� Q Q az EL E Z ELI R� eJ IL a 0 LL Z Z) O U w U Z) J Fr Aftalaw ULM UL m W w DRAWN® R.BROWN CHECKED DATE 01-05-01 SCALE AS NOTED JOB NO. 01-2524 SHEET P01 OF SHEETS (2) 4".CONDUITS W/ (3) 500 MCM THWN U G ELECTRICAL SERVICE - AND 250 MCM THWN NEUT. (INCOMING SERVICE) SEE BITE UTILITY AND PIPINT PLAN FOR LOCATION CT METER 800 AMP C.T. ENCLOSURE 800 AMP'MAIN DISCONNECT PANEL M N CCOOONLEDR ,cav. " ONL D ra¢J OPCDEONENLDI A, IR 8 C28 C1 420/3� 0/3C2,4 C29,31 /3 30¢ BROWN ELECTRICAL PANELS A30 SEE PANEL SCHEDULE SHEET L33 WALK— A37 !WALK-IN TELEPHONE EQUIPMENT -CO LER ''. ERE'EZER BOARD THIS AREA TORAGE < Ell A 2,4,6 B37 AHU 0 #1 4 3 0 0 UTILITY ROOM OFFICE / A39 -IN CO ER AHN #2 4 �B,iQ,1 F 7 F —1 F —1 F 7 7 F_ 77 _ A 2 6, 2 8 IL U lip \ / B17 �. J A33.,35 C23 C29,31 C�,27 C33 1 aU 7 —.N C23 C16 O /H C6 \ � i B2,4 02,4 C26 C 10 ,14 B12 C20. C27 C37 C21 00 0 1 o — — —\ 25 C24 C30 C17 C1 I I C5.:. Ba B10 Bsa I B14,16 HL Electrical Specifications and Notes: 1. Work includes the complete electrical system defined by the drawing set for the project �N THE WALL �.�� B18,20 I includingr ABOVE CO17LER *Electrical load) centers ce gcomplete and t with dering irectories, covers and all circuit breakers. OG B24 I I *Lighting and emergency power off contactors.' C29,31 *Complete branch circuit and control:. wiring including contactors, receptacles, timers, B28 F,p o/ toggle. and safety switches for lighting, signs, `dispensers, ;monitoring equipment B22 "� - hvoc. etc. C30, *Complete and continuous grounding system. INSTA o *All materials, equipment, lobar required to complete the installation intended in IA 14,16.1840/3 I AHU. I � these drawings.. r #3 °� 2. All materials and equipment sh®II conform with the standards of UL, ANSI, ASTM and NFPA. The minimum standard for all work is NFPA 70 (NEC). _ 3. All wiring materials downstream from the meter shall be copper. Aluminum wiring is not \ \ B26 I MEN acceptable under any circumst®hces \ MEWS 4. All panels and circuit breakers §hall be .Square D with "visi trip" indicators. \ L41 5. All .lighting contactors shall be mechanically held. :;' \ \ B9 6... Conceal all conduits in floors, walls or ceiling unless otherwise noted on plans. 7. Increase, wire Sizes as required to maintain voltage drops of 3% or .less from the \ \ , distribution panels. \ - 8. Contractor shall verify the ground fault load with the Utility company and make B27 \ \. V `' I U� equipment provisions as necessary. �u .Y - 9: Unless otherwise no ted, no undergroundconduitsshall be smaller than3 4" / -' 823 O 10. All outlets and switch boxes shall be flush mounted d' d \_11. All convenience outlets should be. mounted at 18" unless otherwise indicated on plans. �- rr • - All switches shall be 48" to .the top above finished floor unless otherwise indicated on plans. L41 12 The electrical loads shall be balanced between legs at the time of final Inspection. - OFFICE TRANSACTION _ PR E A II Farmsh written report of actual loads to General: Contractor., B13 13. Use flexible conduit to connect to all vibrating machinery such as compressors, (ELEC. DOOR condensers etc. - II J LOCKS) VVOM EN ' d ❑ 14. All interconnected dispensers, consoles terminals shall be on the some phase: 0 p ❑ C7 ❑ ❑ 0 OW C7C7 O ❑ O C7 3 15. Contractor shall verify equipment power requirements prior to. construction. 4 Plex conv. outlet Convenience Wayne Plus Equipment - Hubbel #5262 'Wayne Plus Outlet 4 Plex conv. outlet Hubbel #IG-5262 2 3 4' ELECTRICAL POWER PLAN 4%4" Junction Box 2-0 SCALE: 1/4n=1'-On w/safe outlet Intercom J-Box Electric 3m door strike equip Intercom a ° .. ..... see detail at left System I `Electric door .strike power supply Controls .Cable to door 6'x6"x24"` strike remote switch. Wiretrough '_24v DC circuit in flex INTERIOR LIGHTING SWITCH 2(Safe Receptadl®) —'- `door conduit to elect 2 Flex conduits in 2O _G„ EXTERIOR LIGHTING. SWITCH cabinet raceway - O O White FUEL SYSTEM KILL SWITCH i Return Block iC C. 1/2" Conduit to telephon y e ® equipment utility room 24 VDC Ckt. t0 door '�. / 0 7Rigid conduits to J3 P� 1/2' Conduit to each 3-Coed. cable / e e electric pane oar B ( # SA�i SO SC a island for intercom in rear of building -Strike Solenoid q. � i/2" Conduit for carwtlsh 3�#18AWG Black 2� 18AWG Stranded Copper)�s T'e° nk {if required) Belden 8791 White + / J e4 other conduits for # .White 6"x6"x24" WIRE TROUGH S < i' Conduit camerae optional features (Or eq.) White �I{-) " �+fe data (if required) - 24 VDC Retifier Black', ;(+) Adams Rite #4603 Block Terminate 2" AFT (� Spot Toggle Switch 3' PVC to Switch /a Radio Shack #272 654 Terminal Board office Return ((wJ0)) Radio Shack #27A-658 (or eq) I _ (- 28 Volt lamp assy. (red) Fuse Holdet w/ SA-125V Fuse Radio Shack #272-325 Radio Shack l 5 12 (or eq) w/ 272-1119 lamp - TRANSACTION .AREA ELECTRICAL LAYOUT DETAIL 6"x4"x3" Screw Cover J box ARRANGE TO ACCOMMODATE ACTUAL EQUIPMENT AT THE SPECIFIC LOCATION. 4"x2"x1 5/8"' box N H Hoffman #A604SC (or eq) + O w/ Hoffman #A-6P4 mtg. panel I 4 on lower shelf Radio Shack #270-231 SECTION A 7� - TRANSACTION AREA COUNTERTOP EQUIP Remote switch Adams v t #460 Transformer NTS � I � THESE PLANS AND ALL PROPOSED WORK Mount .atop counter Adams Rite #4605 ? o ° m 2. Wayne Plus 3 receipt printer ` FILE : ARESUBJECTTOANYCORRECTIONS Ground Q Q ° o w 1. Wayne Plus 3 control system COPY t0 box I.. a.. - ti o m I 3. Wayne Plus 3 journal printer REQUIRED BY FIELD INSPECTORS THAT,: > z 4 Intercom, system ip - t - Insulating Grommet aN c zo a 4A Intercom system equipment - 3M D2S MAY BE NECESSARY IN ORDER TO 5 Pumps/Dispenser Emergency Power Off Switch. Power Supply " 6 Telephone 7. Electronic Safe • , YWITH LAPP61CA8LECODES LAYOUT DIAGRAM - 8. Momentary contact switch lighting control Wayne Plus 3 System -9. Electric door switch - .:convenience Rece t.. P eVi s 10�1 ,Convenience Recept. Emergency Power OFF e 5A 6"x6%24" Wireway 2 PILA electric. # FS120 . D, E3 mushroom w/PILNCCB REM Telephone Jack , contacts or; equal 120VAC JU4603 3" Data conduit �' OUTSIDE LIGHTING CONTROL SWITCH 'LAMP �: Controls operation of lighting contactor for Panel 1" J zQ zc J z.c ?¢ 4605 RECT. COIL - ELECTRIC DOOR STRIKE POWER SUPPLY momentary "on" (2 positions) NOTE' S Conduits to '. 24 VDC output. See detail THIS', SHEET 0t normally.'off" SPOT 15A, 120V - PROVISIONS SHALL BE MADE FOR MANUAL OVERRIDE MECHANISMS (HC ACCESSIBLE) TO ALLOW intercom speakers 2 #18 AWG stranded copper wires in flex Hubbell 1556-I ore w stainless # ( q) and corwash controller (optional) cat. to door strike unit. g Elea, door strike steel cover late. Install in a P EMERGENCY ESCAPE UPON POWER INTERRUPTION SCHEMATIC DIAGRAM remote switch 2-gang box w/inside light switch. OPTIONAL ELECTRIC DOOR STRIKE SYSTEM TRANSACTION AREA UNDER CABINET UNDER FLOOR WIRING TRANSACTION COUNTER LAYOUT NTS.. I �I d Q O LL H Z 0 U _J LL LL o J m W W CHECKED DATE 01-05-01 SCALE AS NOTED JOB NO 01-2524 SHEET E01 OF SHEETS III L�� ...I. Mimi -- l: •I . wo WE ® IIIWI W lwiml�� ��—�i:1.:111—.1 c �SS'i��©0��`i • 1 c �.,��.��Kiaill®�� • - ��--�S:i:IUl:igKi•¢�.y�( ' 1 c �it�y � �KbZq�- • _ , _ I�-�r1•,11---'�"�"'��iYYi�00Vlli��i ��`.'il¢*,��©0���� ' 1 L �r�41•�•:��- ' _ ' , _ ��—I�i%ili--�S���iii�0�' E'1L'!I■1�7�,—�.�i:i:i.111�— ` - • _ ��id:isPl_—l:I1TK1•�(s�`:y��®��i��iiLT:,—�:K1'.'III�. � • - • _ ' ����i�:��s�'j�®�����ia.�s����id:fll�ii��o`�� • __ , __ «• • o- • ■ "�l•[I[UARK ---KI4KI■�i���• «• • - • • Its—i,yI.1—I�a/1G1— ■ ° — �..�� ' _ ��yl�r��i�®���i�ii�y��i�y.�y,—{_r l--{fir, •• - • • ����iu��ra���i%y■®��rr�l■�Ir�rurl■�.�Iii��� ' ■••- •• ��—■�Iii%u��Iriiiinrr�]'r(l��tlfr�r�ll�{��■®����� ` p����lt� «• • - ���r'.v���lr�'�r'i1�I��lrrrirlr��l■®�_������.1���* «•• _ ��—�$:111—i�xx11�11�iC�lifC-Y■��—_—!, ?x !� .'_i�WG.� -----IWWWWWWWW��WWWWWWWW�WO�—s �� ���� s—e�•WWWWW�WW® ••ses >_ WWWWWWW..: _ . ® 1 1 ®_®®®_®®_®_IIIIIIIIII,®_®_IIIIIIIIIIIIII do, M4 Total connected V �®®�®®®®®® .. _ - • ®®`...,/® ®fir' Norilconthuous Kitchen Equipment ONE= MINI SQUARED NQOD442L225 '225 AMP MA 1 115/208 VOLT 3 PHASE 4WIRE PAN EL B 10000 AI Load VA Amps/ Wire Cond. Cond. Wire Amps/ L k VA Load Directory Category A B C N Poles Size Size # # Size Size Poles N B C Catego "•'>" ad Dlrect0 ATER HEATER FOOD SERV ICE LIGHTS 1 2 SALES AREA LIGHTS 3 4 WATER HEATER SALES AREA LIGHTS 5 fi HIS TA KE-OUT SIGN SALES AREA LIGHTS 7 8 SPARE CONY. RECEPT. 9 —1 1 1.0 12 SPARE BEVERAGE CENTER OFFICE/STOREAGE LIGHTS 13 14 AIR POT BREWER DOOR STRIKE 15 16 AIR POT BREVVER R.R.1 VESTIBULE LIGHTS 17 18 i AIR POT BREWER RECEPT ABOVE COOLER 19 20 AIR POT BREWER RECEPT A BOV E COOLER 21 22 :. fi� CA PPUCINO CASHIER RECEPT. 23 24 CAPPUCINO CASHIER RECH I. 25 26 COUNTER RECEPT. CASHIER RECEPT. 27 28 Areal,, SPARE SAFE 29 30 INSTA-HOT WATER CONV RECEPT. low 2071 31 32 INSTA-HOT WATER OFFICE RECEPT. 1 (JUL) 33 34 a: COFFEE GRINDER OFFICE RECEPT.5TFI 35 36 i SPACE. UTILITY ROOM RECEPr. 37 38SPACE M12795 STOREROOM RECETP. 40 PANEL SPACE39 41 42 1 4" PANEL SPACE Subtotalconnected VA _ 3700 3930 5170 12800 25720 12090 17135 Subtotal connected VA Total connected VA (A) 15790 VA Total connected VA (S) 16725 VA Total connected VA C) 22305 VA � - Total connected VA 54820 VA '``' "';!`' �� Totalneutral' load 38520 Connected Demand Load VA Load VA NEUTRAL LOAD: 38520 1208 X 1:73= 107 AMPS Non -continuous 1 20120 0 100% 20120 Continuous 2 6200 @125% . 7750 - ]Kitchen E ui ment q P 3. 28500 @ 65% 18525 r Total connected Load I I b4d2l)l 46395 DEMAND LOAD: 46A9 §t"208 X 1.73 MPS' owuAKt L) MAW- 1440-0 wv r�rvir ivies ,vuvir. an 115/208 VOLT 3PHASE 4 WIRE M DP 22000 AIC Load Direct. � ..d Directory 000© ©000 —il.T.i.7.7---YY1.7K��i'�(1� •�:i�0©�•'��.u1�YYk7K�—tlfiCl1I11--- • —ib—�'I'i�l�'L�©�'f'�iiul��-- Z![/l 1�'1—�•. ---i•1.isIlI1]—vr��x��ii{J��©����.ul��i---Ilif[.'t:ill— - • —�1E.7[-111---�Y�TK�`'rfV��O���ii�1�Y��7K�—�CiIiLl11--- • --ii[:lrlil--f•.Yk7Kl�f(I,r�rr.�rO�Y.i1Ii■�,((1� r�(c�--IIIIIIIII■IiGrlll---• ---�•YXilb7—���i�l��•'��®�'�iul���---�•�'Lltill— - • —Illlllllllf'lR.'Yi[II---P.i'.M7Kl�(1]rrrrv�®�f;�ac� --Illlllflib%111--YYb7Kl�!(I,r.�rr�®��(�tr� 1/ --Illlllllll�ilitl-- ---i•1:51111—rrlT/.:��(l, •�'���iflfLffl� 11 Subtotal connected connected VA 63255 62745 f71775 0 Total connected VA (A) 109445 VA Total connected VA (B) 108305 VA Total connected VA (C) I 116535 VA Total connected VA 334285 VA Connected Demand Load VA Load VA Non -continuous 11 165100 @ 100%M31O449.3 Continuous 2 58965 @125% Kitchen Equipment 3 110220 @65% Total connected Load 334285 0 1 46190 1 45560 1 44760 Total neutral load 120145 NEUTRAL DEMAND LOAD:120145 + 14741 CONTINOUS LOAD / 208 X 1.73 = 375 AMPS NONCOINCIDENT LOADS ARE CW-7,9,11, A-1,3,5, A-7,9,11, AND A-13,15,17. 50310 VA DEMAND LOAD: 310449 - 50310 / 208 X 1.73 = 723 AMPS Subtotal connected VA SQUARE D Q0440M2125 225 AMP MAIN BREAKER NEMA1 I3EWISIONS BY 1151208 VOLT 3 PHASE 4WIRE PANEL CiW 10000 AIC • "• " �•�Si1Y:iq®��rr• 'a�7rr�©o�%II■ie�' / ��� • 1 �ii " • "• ��®®��: •�—�'�'���III©IIIOLIlL'!I■iCi��lllll�--���� " - -• iii'Ki:lll®®� Il �Jfff%yI00f1Y41■i!'�CWC���tE%Ll®Sii-• ' • -• �'—®i`ki$q® /l �.]�(i'��®[cjL�i(•j(Cj](.�---IIIIIIIIIIIIIIINIIi[Il�� - • -- •- •- - i'�71[:ilj®�®��`�%�®�[sj(��[][cb7Ki■—�lllibls—�' • . • .. •. ■- - ��—iS[:ill®®r•Li�a�7ir�®�FlL'fl■iLIJLri�—� 1 • —�'' . • .. •. •- i---��®EiIIKi•`:j���� •��'JY:gi�ib'7u--Illllllllllllllrl:tn� « •" ���• �—®I�ti9Lr�S7flii���i1C�■iC#C�11(I��Itll]I�IL'tIJ--�� • • i�1��71LY']®� •i�,lt7��®®ilC�iCi C39(I��P1��L'111—�- - •« ��—®��9—��`y��®��'��'�13•���r'1--Illlirlll�� « - -•• - _•• ��I�susl� e�l���r��l■®�r��l■�r�ru���lrl�x��'�����e, • �'�������e�l��rlrr�l■®�rural■�r�e�•rrl���%.u������ ------��—�®"e�--IIIIIIIIIIIIIIIIIIIIIIIIII■--� .. Subtotal connected VA Total connected VA (A) Total connected VA (B) Total connected VA (C) Total connected VA Non -continuous Continuous Kitchen Equipment Total connected Load 24800 1 24540 1 24360 162D 31140 VA 31020 VA 29430 VA 91590 VA 1 4730 1 6340 1 6480 1 5070 1 Subtotal connected VA Total neutral load 5350 Connected Demand - Load VA Load VA NEUTRAL LOAD: 5350 1208 X 1.73 =15 AMPS 1 73890 @ 100% 73890 CW-7,9,11 IS A NONCOINCIDENT LOAD WITH CW-13,15,17, AND CW 19,21,23 28080 VA. 2 17700 @125% 22125 3 0 @65% 0 91590 96015 DEMAND LOAD:96075 - 28080 /208 X 1.73 = 189 AMPS SQUARE D NQOD301_225 225 AMP MLO NEMA 1 1151208 VOLT SINGLE PHASE 3 WIRE PANEL G 10000 AIC Load Directory Category Load VA Amps/ Poles Wire Size Cond. Size # # Cond. Size Wine Size Amps/ Poles Load VA Category Load Directory C B N N DISPENSER 192 1 2 REG. STP DISPENSER 1&2 3 4 REG. STP' DISPENSER 3&4 5 6 MCB SUPER STP DISPENSER 3&4 - 7 8 SUPER STP DISPENSER 5&6 9 10 DIESEL STP DISPENSER 5&6 bVVN 1 127'-11-123/4"DIESEL STP DISPENSER 7&8 13 14 3/4" uuTLS-350 DISPENSER 7&8 15 16 SPACE DISPENSER 9&10 17 18 SPACE DISPENSER 9&10 0 VA VA VA 19 21 23 25 27 291 4600 20 22 24 _30_ 26 __-__ 28 ___ ___ 30 C 700 r--r-1 1 4150 SPACE SPACE SPACE SPACE SPACE SPACE 1 3450 1 Subtotal connected VA SPACE SPACE SPACE SPACE SPACE Subtotal connected VA Total connected VA (C) Total connected VA (B) Total connected VA 4600 I 8750 3450 12200 Connected Demand Load VA Load va Non -continuous 1 12200 @ 1009% 1 12200 Continuous 2 0' @125% 1 0 _ Kitchen Equipment 3 0 @65% 1 0 Total connected Load 12200 12200 SQUARE D NQOD442L225 1151208 VOLT 3 PHASE 4 WIRE I Otai neutral IOaa I JJVVI NEUTRAL LOAD: 53001208 = 25 AMPS DEMAND LOAD. 12200 / 208 = 59 AMPS 225 AMP MLO NEMA 1 PANEL L 10000 AIC Directory _ LIGHTED. •.. - �'� •�1--iIII:IIlYil1Y��''����©�'�:a��1�'�•f���'•�--�.'� ' •- ��������r��Ir�rul�o��ey■�lur:�rl��lrsu��lrsu���•• • •- ��--�1]i4'till����'����®�{i��1�1:'{I:����iii•�--�i:'��'�-. . •- �i6*all—■�y�+ —iK2a'./11�j1Jj��•�`�®�[.f(i� f(1�` 1 ��iiii�Til�'�lir—�.'_�� • ' •- �'��iIF1I9�ik119P39i■tIL9KIL•!I■®®flC�f■fE'�EiITII�irYl�l�llllifr�g���: ' •- l�tlFYi•]���'Ii']C'PJi�fE'�KIL71■®���� ���� Liu ---�-�,{���rr��TT����-M-M_r,'��_11����"�r1i���.11i1 r�4ti��r��M Subtotal connected VA 1 6530 1 4920 1 7270 1 18720 Total connected VA (A) 11400 VA Total connected VA (B) I 10890 VA Total connected VA (C) 11680 VA Total connected VA 33970 VA Connected Demand Load VA Load VA Non -continuous 1 6140 @ 100% 6140 Continuous 2 27830 @125% 34787.5 Kitchen Equipment 3 0 @65% 0 Total connected Load 33970 40927.5 1 15250 1 4870 1 5970 1 4410 1 Total neutral load 33970 NEUTRAL LOAD: 33970/208 X 1.73 � 04 AMPS DEMAND LOAD: 40928 / 208 X 1.73 = 114 AMPS BROWN BOX nµ•CW/ 800 AMP GT. C.T. MDP . m aua PL ENCLOSURE A B O MLTER 2-0 L W/ PolF1. WIFL > WN «W C G 250 YpI11M1 NpR. FP&L 4- W a// saxWoes an 0]«FCIEO W 2- aus sm, ue Subtotal connected VA 0 Ritevisloyl SLwr 9{161e1 THESE PLANS AND ALL PROPOSED WOFiit ARE SUBJECT TO ANY CORRECTIONS Pma REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. ur #2 GROUNDING ELECTRODE CONDUCTOR nA10N 1j�—_�L/ CONNECT #10 TO 2-5/800 GROUND ROD BLDG. STEEL AND COLD WATER PIPE #8 GROUNDING ELECTRODE CONDUCTOR CONNECTED TO 2-5/800 GROUND RODS ® D.F. CONSULTANTS, INC. CIVIL ENGINEER: WILLIAM DUFFEY, P.E. 9000 SHERIDAN STREET SUITE 136 PEMBROKE PINES, FLORIDA 33024 �1JC. TELEPHONE: (954) 431-4846 P.E.# 0024433 E.B.# 0007007 ®■ DRAWN HECK® DATE 01-05-01 SCALE AS NOTED JOB NO. 1-2524 SHEET IE03 OF SHEETS