HomeMy WebLinkAboutEagle Capristano.pdf8/26/2020 Florida Building Code Online
: ir
A
BCIS Home Lag In User Registration Hot Topics Submit surcharge Stars a Facts Publications Contact Us BCIS Site Map Links Search
db:pr
�_ �) Product Approval L�\(((���
USER: Public User
Product Approval More > Product or Application Search > Application Ust > Application Detail
FL # FL7473-R8
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer EAGLE ROOFING PRODUCTS FLORIDA LLC
Address/Phone/Email 1575 East CR 470
Sumterville, FL 33858
(800)400-3245
annettes@eagleroofiing.com
Authorized Signature Annette Sindar
annettes@eaglemofing.com
Technical Representative Tyler Allwood
Address/Phone/Email 1575 East Country Road 470
Sumterville, FL 33585
(941)302-7826
tylera@eagierooflng.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Tiles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluatlon Report
Florida License
PE-59166
Quality Assurance Entity
Architectural Testing, Inc., an Intertek Company
Quality Assurance Contract Expiration Date
12/31/2020
Validated By
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Standard
ASTM C1492
FRSA/TRI April 2012
SSTD 11
Year
2009
2012
1997
Sections from the Code
htips://www.floridabuilding.org/pr/pr�_app_00.aspx?pamm= GEVXQwtDgt8Bwwt9vil P(VBTji%2f7gT7ap/*2fiMUFZfllM%3d 1/2
8/26/2020
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option D
10/16/2017
10/18/2017
10/19/2017
12/12/2017
FIL # Model, Number or Name Description
7473.1 Eagle Roof Tiles I Low (flat), medium and high profile concrete roof tiles
Limits of Use I Installation Instructions
Approved for use in HVHZ: No 1 FL7473 R8 II 2017 10 FINAL ER EAGLE NON -
Approved for use outside HVHZ: Yes HVHZ FL7473-R8.gdf
Impact Resistant: N/A Verified By: Robert 1. M. Nieminen PE - 59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See Section 5 of Evaluation Report for Limits of Use. I Evaluation Reports
rile roofs are analyzed for wind resistance through overturning i FL7473 R8 AE 2017 10 FINAL ER EAGLE NON -
moment. Refer to FRSA/rRI 07320 for overturning moment i HVHZ FL7473-R8.gd(
limitations of mechanically attached tile systems and the the Created by Independent Third Parry: Yes
adhesive manufacturers' Product Approvals for adhesive set tile
systems.
Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employee 5=y_dght 2007-2013 State of Florida.:: Pdvila statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.'Pumuant to Section 455.275(3),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 45S, FS., please dick hen g.
Product Approval Accepts:
®® ® E
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app_dd.aspx?pamm=wGEVXQwtDgt8Bwwt9vil PtVBTji%2f7gT7a%2fuMUFZfl 1 M%3d 2/2
TRINITY ERD
EVALUATION REPORT
EXTERIOR RESEARCH & DESIGN, U.C.
Certificate of Authorization N9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203)262-9245
Eagle Roofing Products Florida U.C. Evaluation Report E1322.09.06-RS
1575 East Country Road 470 FL7473-R8
Sumterville, FL 33585 Date of Issuance: 02/24/2009
(800) 400-3245 Revision 5:10/16/2017
SCOPE:
This Evaluation Report is issued under Rule 614320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6u' Edition (2017) Florida Building Code
(NON-HVHZ) sections noted herein.
DESCRIPTION: Eagle Roof Tiles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Evaluated by Robert Nieminen, P.E." may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPEcnON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
OF •W-
T. thetatsimile seal appearing was authorized by Robert Nieminen,
"P.E- on 10/16/2017. This does not serve as an elenw,dolly sign"
4� C document Signed d seal"hardwpies have been transmitted to the
t,4t- �sO
pmduaapprovai pdminrsttatorand to the named dent
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
t TRINITY ERD
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category:
Roofing
Sub -Category:
Roofing Tiles
Compliance Statement:
Eagle Roof Tiles, as produced
by Eagle Roofing Products Florida LLC, have demonstrated
compliance with the following sections of the a
Edition (2017) Florida Building Code (NON-HVHZ) through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /
Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard Year
1507.3.5, R905.3.5
Physical Properties
ASTM C1492 2003(2009)
1507.3.7, R905.3.7
Attachment Requirements
FRSA/TRI April 2012 (04-12) 2012
1504.2.1.1
Overturning Moment
SSTD 11 1997
3. REFERENCES:
Entity
Examination
Reference
Date
ATL (TST 3782)
ASTM C1492
RT0310.01-17, 02-17, 03-17
03/15/2017
ATL (TST 3782)
ASTM C1492 — Freeze/thaw
RT0706.01-17, 02-17, 03-17
09/25/2017
Tile Roof Institute
SSTD 11
Membership Letter
11/29/2005
ATI (QUA 1844)
Quality Assurance
Inspection Report
06/07/2017
4. PRODUCT DESCRIPTION:
4.1 ASTM C1492, Type III (Low Profile):
FBELAIR
Exterior Research and Design, U.C.
Certificate of Authorization #9503
r
W
67H EDITION (2017) FBC NON-HVHZ EVALUATION
Eagle Roofing Products Florida LLC.; (800) 400-3245
�y �
Evaluation Report E1322.09.06-RS
FL7473-R8
Revision 5:10/16/2017
Page 2 of 5
4.2 ASTM C1492, Type If (Medium Profile): MALIBU
N4M1
/IOte
1.
4.3 1 ASTM C3492, Type 1 (High Profile):
S. LIMITATIONS:
CAPISTRANO
TRINITY ERD
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire classification is not part of this evaluation; refer to FBC 1505.2, Exception 2 (for non-combustible
deck) or listing by an approved testing agency for fire rating of this product.
5.4 Underlayment shall be that which holds Florida Product Approval for use with tile roofing systems. The
underlayment Product Approval shall specify allowable method(s) of tile installation (mechanical
attachment, mortar -set and/or adhesive -set) for use with the specific underlayment. For mortar -set or
adhesive -set tile roofing applications, the underlayment Product Approval shall specify attachment
methods for the underlayment system to resist wind uplift design loads in accordance with Table 3A of
FRSA/TRI April 2012 (04-12).
5.5 "Color -Bonded" or "Slurry -Coated" files are limited to use on projects in areas subjected to weathering
indices of 50 or less (negligible weathering), as outlined in Figure 1 of ASTM C3492-03(2009)I, reproduced
below for reference. This limitation does not apply
........ .... 50
5O 50
WEATHERING REGION
NEGLIGIBLE WEATHERING
MODERATE WEATHERING
SEVERE WEATHERING
to the "Color -Through" product offering.
5.6 All products in the roof assembly shall have quality assurance audit in accordance with FAC Rule 61G20-3
Exterior Research and Design, I.I.C. 0 EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report E1322.09.06.RS
Ceni/(mte ofAuthod otion #9503 Eagle Roofing Products Florida LLC.; (800) 400-3245 FL7473-R8
Revision 5: 10/16/2017
Page 3 of 5
TRINITY ERD
6. INSTALLATION:
6.1 Eagle Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with
manufacturer's current published instructions, but not less than the requirements of FBC 1507.3 and the
FRSA/TRI Florida High Wind Concrete and Clay rile Installation Manual.
6.2 Underlayment shall be installed in accordance with FRSA/TRI April 2012 (04-12) or the underlayment
manufacturer's current Product Approval. For mortar -set or adhesive -set tile roofing applications, the
underlayment current Product Approval shall specify attachment methods for the underlayment system to
resist wind uplift design loads in accordance with Table 1A of FRSA/TRI April 2012 (04-12).
6.3 Tile Attachment:
6.3.1 Mechanically Attached Tile:
Wind load resistance shall be in accordance with Table 3 of FRSA/TRI April 2012 (04-12) to resist the Uplift
Moment determined in Table 2A or 2B of FRSA/TRI April 2012 (04-12) or FBC 1609.5.3.
6.3.2 Mortar -Set Tile:
Wind load resistance shall be in accordance with Table 2A or 28 of FRSA/TRI April 2012 (04-12) or FBC
1609.5.3 in conjunction with the mortar manufacturer's Product Approval.
6.3.3 Adhesive -Set Tile:
Wind load resistance shall be in accordance with Table 2A or 2B of FRSA/TRI April 2012 (04-12) or FBC
1609.5.3 in conjunction with the adhesive manufacturer's current Product Approval. Refer to the current
version of the referenced Florida Product Approval for paddy -placement details and performance data.
TILE ADHESIVES FOR ADHESIVE -SET TILE SYSTEMS
Manufacturer
Products
Florida Product Approval
DAP Foam, Inc.
'Touch N'Seal Storm Bond"
FL14506
'Touch N'Seal Storm Bond 2"
FL21374
Dow Chemical
'TILE BONDTM"
FL22525
ICP Adhesives & Sealants, Inc.
"PolyseN AH-160"
FL6332
"Polyseta RTA-1"
FL6276
6.3.4 Hip and Ridge Tile:
Tile shall be installed in accordance with FRSA/TRI April 2012 (04-12). For hip and ridge tile installations
atop hip and ridge metal, refer to the hip and ridge metal manufacturer's current Product Approval (e.g.,
FL5374) or test report in accordance with SSTD 11 for allowable loads to resist those determined in
accordance with Table 1A of FRSA/TRI April 2012 (04-12).
Exterior Research and Design, U.C. 6r" EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report E1322.09.06-RS
Certpicate ofAuthorkation #9503 Eagle Roofing Products Florida LLC.; (800) 400-3245 FL7473-RS
Revision 5: 10/16/2017
Page 4 of 5
TRINITY ERD
7. LABELING:
7.1 Each unit shall bear the imprint or identifiable marking of the manufacturer's name or logo. Tile lots shall
be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein.
EAIGLE��
FLORIDA
EAGLE FL
(LOCATED ON L\-DERSIDE OF TILE) (LOCATED ON FRONTSIDE OF TILE)
7.2 Tile not tested for freeze -thaw shall state clearly that the lot has not been tested for freeze -thaw
acceptance on all lot tags or certification.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Sumterville, FL
10. QUALITY ASSURANCE ENTITY:
Architectural Testing, Inc. — QUA1844; (717) 764-7700
- END OF EVALUATION REPORT -
ASTM C1492-03, Standard Specification for Concrete Roof Tile, m ASTM International
Exterior Research and Design, U.C. 6'" EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report E1322.09.06-RS
Certif sate of Authorization #9So3 Eagle Roofing Products Florida LLC.; (800) 400-3245 FL7473-R8
Revision S:10/16/2017
Page S of S