Loading...
HomeMy WebLinkAboutWincore 8800 DH G1_G2 15819.2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL15819-R10 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Wincore Window Company, LLC Address/Phone/Email 250 Staunton Avenue Parkersburg, WV 26104 (304) 485-7460 Ext 228 dgeorge@wincorewindows.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Mike Reed Address/Phone/Email 250 Staunton Turnpike Parkersburg, WV 26104 (304) 485-7460 Ext 228 mreed@wincorewindows.com Quality Assurance Representative Mike Reed Address/Phone/Email 250 Staunton Turnpike Parkersburg, WV 26104 (304) 485-7460 Ext 228 mreed@wincorewindows.com Category Windows Subcategory Double Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Lyndon F. Schmidt, P.E. Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan J. King, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL15819_R10_COI_(b) Certificate of Independence.pdf Referenced Standard and Year (of Standard)Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2008 AAMA/WDMA/CSA101/I.S.2/A440 2005 ASTM E 1300 2004 ASTM E1886 2005 ASTM E1996 2006 TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/20/2019 Date Validated 02/20/2019 Date Pending FBC Approval 03/01/2019 Date Approved 04/16/2019 Date Revised 07/07/2020 Summary of Products FL #Model, Number or Name Description 15819.1 a. 8400 Series Vinyl Double Hung Window Extruded PVC Double Hung Window with "Non-Impact" Insulated Glass Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 15819.1 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15819_R10_II_(b) Inst 15819.1.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15819_R10_AE_(a) Eval 15819.1.pdf Created by Independent Third Party: Yes 15819.2 b. 8800 Series Vinyl Double Hung Window Extruded PVC Double Hung Window with "Impact" Insulated Glass Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15819.2 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15819_R10_II_(b) Inst 15819.2.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15819_R10_AE_(b) Eval 15819.2.pdf Created by Independent Third Party: Yes 15819.3 c. 8800 Series "HVHZ" Vinyl Double Hung Window Extruded PVC Double Hung Window with "Impact" Insulated Glass Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15819.3 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15819_R10_II_(c) Inst 15819.3.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15819_R10_AE_(b) Eval 15819.3.pdf Created by Independent Third Party: Yes 15819.4 d. 400 Series Vinyl Double Hung Window Extruded PVC Double Hung Window with Nailing Fin - "Non- Impact" Insulated Glass Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 15819.4 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15819_R10_II_(a) Inst 15819.4.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15819_R10_AE_(a) Eval 15819.4.pdf Created by Independent Third Party: Yes 15819.5 e. 500 Series Vinyl Double Hung Window Extruded PVC Double Hung Window with Nailing Fin and Integral "J" Channel - "Non-Impact" Insulated Glass Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 15819.5 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15819_R10_II_(a) Inst 15819.5.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15819_R10_AE_(a) Eval 15819.5.pdf Created by Independent Third Party: Yes 15819.6 f. 5400 / 5400S Series Vinyl Double Hung Window Extruded PVC Double Hung Window with "Non-Impact" Insulated Glass (Double Strength Glass with Reinforced Sash) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 15819.6 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15819_R10_II_(a) Inst 15819.6.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15819_R10_AE_(a) Eval 15819.6.pdf Created by Independent Third Party: Yes 15819.7 g. 5400 / 5400S Series Vinyl Double Hung Window Extruded PVC Double Hung Window with "Non-Impact" Insulated Glass (Single Strength Glass with non-reinforced Sash) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 15819.7 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15819_R10_II_(a) Inst 15819.7.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15819_R10_AE_(a) Eval 15819.7.pdf Created by Independent Third Party: Yes 15819.8 h. 7700 / 9000 Series Vinyl Double Hung Window Extruded PVC Double Hung Window with "Non-Impact" Insulated Glass Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 15819.8 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15819_R10_II_(a) Inst 15819.8.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15819_R10_AE_(a) Eval 15819.8.pdf Created by Independent Third Party: Yes 15819.9 i. 7700 / 9000 Series Vinyl Double Hung Window Extruded PVC Double Hung Window (Reinforced Sash) with "Non-Impact" Insulated Glass Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 15819.9 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15819_R10_II_(a) Inst 15819.9.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15819_R10_AE_(a) Eval 15819.9.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: